Home

Supreme Heating User Guide

image

Contents

1. The Solar Collector included in the Product carries a in the case of a Strip Collector a ten 10 year limited warranty from Procom Plastics Extrusions Pty Ltd 38 McGregors Drive Keilor Park Victoria 3042 Phone 03 9331 7589 Email sales procomplastics com au or in the case of an Evacuated Tube Collector a ten 10 year limited warranty from Supreme Solar Pty Ltd 9 Lucknow Crescent Thomastown Victoria 3074 Phone 03 9460 4200 Email info supremeheating com au in the case of an Oku Panel Collector a twenty five 25 year limited warranty from Supreme Solar Pty Ltd 9 Lucknow Crescent Thomastown Victoria 3074 Phone 03 9460 4200 Email info supremeheating com au i If during the initial twelve 12 year period the Panel shows a manufacturing defect a new panel will be supplied at no cost to the original purchaser ii If during the next thirteen 13 year period the Panel shows a manufacturing defect a new panel will be supplied to the original purchaser at one half of the current retail price Any labour travel and freight costs incurred are excluded from this warranty Such costs are to be paid by the owner and is the only warranty given in respect of that part of the Product 21 Supreme Heating User Guide 4 The Automatic Controller included in the Product carries a in the case of a SSV or Aqua Gen 3 Series of Automatic Controllers a three 3 year limited wa
2. C above the temperature limit Normal heating will occur the next day if the pool drops below the temperature limit by 1 C Manual Mode is for testing the pump installation on a cold or cloudy day Once manual mode is selected the pump will start if it has been off or stop if it has been on running After 30 minutes manual mode will time out and return to summer mode with a default temperature limit of 30 C Settings Mode is for setting the unit into time clock operation When you select this option you will be asked if you wish to use the clock feature CLK ON OFF If you select OFF then the controller will not work as a time clock model and will allow the solar pump to run whenever there is solar heating available If you select ON you will be prompted to set the time of day the controller will work in time clock mode and the solar pump is prevented from starting outside of the set hours unless tropical mode is selected Set the time of day in 24 hour format note there is an AM PM indication to avoid incorrect settings Seconds are automatically set to zero Once the time is set select the START hour from 6am until 12noon default is 9am which means the solar pump cannot start before 9am Now select the END hour from 15 00 3pm until 21 00 9pm default is 19 00 7pm which means the solar pump will stop at 7pm Installer Settings Adjustable differential and anti freeze feature Special note Adjusting these values to any setting ot
3. e Innovative products to achieve maximum aesthetic appeal and to maintain property value e Easy operation and low maintenance e Supports local economy Traditional strip solar system Panel solar system Supreme Heating User Guide Maintenance General Maintenance The solar system has been designed as an absorber of the sun s energy to transfer heat into the pool Ideal protection of the lifespan of the system will occur if water is flushed through the system regularly Automation with Winter Mode has been provided to facilitate this during the winter period Flushing the system out removes any build up of harmful toxins or chemicals which can affect the solar collectors and pipe work If the system is operated manually it is recommended to flush the system for 10 minutes every day during non seasonal periods Long term non operation of the system can result in premature failure of the solar system and will void the warranty period The system should also be checked for any leaks during the inspection of the vacuum relief valve refer below If a leak occurs it should be rectified immediately so as to avoid any roof or property damage Because most pools are salt chlorinated and chemically treated if a leak is left for long periods it will cause irreversible damage Failure to abide by your maintenance schedule will void your warranty Vacuum Relief Valve The vacuum relief valve is installed at the base of the man
4. hot Once the desired temperature is achieved the pump is stopped and a 4 hour wait commences to ensure no energy is wasted by cycling the pump If after 4 hours the roof is hot enough then the pump may start to provide another heating cycle and if the desired temperature is reached again then no heating will occur until the next day unless the controller is operating in time clock mode where heating can occur until solar lockout time 09 00 until 19 00 Supreme Heating User Guide Mode of Operation Pressing the SELECT button once will display the current mode of operation pressing it again or holding it will select the next available mode of operation The available modes are SUMMER MANUAL TROPICAL or WINTER Summer Mode is the normal operating mode for heating the pool Winter Mode of operation is for off season maintenance or if pool heating is not required AWAY MODE This is a better option than turning off the controller as it will flush treated pool water through the solar system as well as prolong pump bearing and mechanical seal life The pump will run for 3 minutes each day from when the winter mode was selected or at 10am if the time clock mode was selected Tropical Mode is for situations where the pool water overheats due to direct heating from the sun beyond the set limit When the roof is 4 C cooler than the pool temperature the pump is started this will most likely occur at night and will attempt to cool the pool to 1
5. pumping and is displaying a higher temperature than expected it may be caused by a pump which is failing to prime check the pump and if necessary prime the pump as per the pump manufacturers instructions then reset the controller by turning it off on Supreme Heating User Guide Solar Pumps At Supreme Heating we use Astral Pool Australia formerly Hurlcon pumps for our solar installations The type of system we install will determine what type of pump is used To determine what pump you have please refer to your quotation invoice or model number which can be found on side of the pump SS Series Solar Pump A high performance high head pump ideally suited for solar applications The SS series pump is Supreme Heating s premier pump designed to operate at high pressures when high pressure is desired Features e Continuous duty rated motor e Precision reinforced moulded high head impeller giving extra performance e Single piece moulded body for added strength and longer life e Rapid priming diffuser quickly corrects loss of water flow e Quick and easy disassembly for servicing e Large capacity basket with easily removed ramp on lid Operation 1 Prime pump if hair and lint pot is dry as follows Close off valve on suction line if present Remove lint pot lid Fill lint pot and chamber with water Replace and secure lint pot lid and seal 2 Open all valves allowing fluid to flow through pump 3 Switch o
6. repeat until the roof temperature rises above the anti freeze temperature Factory Test To run the factory test hold the SELECT button when first applying power the unit will perform a series of self diagnostic functions with the pump running If there are any faults they will be reported on the display before the unit restarts into normal operation Note this will force all settings to a factory default state if anti freeze had been selected then turn it back on as described under adjustable differential and anti freeze feature Also re enable time clock if desired Notes 1 Ifa sensor fault is detected the controller will display which sensor failed POOL and or ROOF and the type of failure 2 Should power be interrupted for any reason the controller will resume normal operation when power is restored all information will have been kept for up to 14 days Temperature sensor used with this unit is digital and is accurate to 0 5 C no calibration is required 4 The sensor cable with the thin trace is the positive and is usually fitted to the right hand side of the green plug when looking at the plug screws incorrect polarity will be displayed as a short circuit or reversed fault 5 Ifthe controller has stopped pumping and is displaying a higher temperature than expected it may be caused by a pump which is failing to prime check the pump and if necessary prime the pump as per the pump manufacturers instructions then res
7. Supreme Heating User Guide Heatseeker Solar Pool Heating Supreme a OAL x Heating Specialists in heating for homes amp pools Solar Pool Heatin g Supreme Heating User Guide Accessing Supreme Heating Technical Support For assistance with the installation or ongoing use of your solar pool heating system please contact Supreme Heating for technical support Supreme Heating Monday Friday 8 30am 5 00pm Phone 1300 787 978 Melbourne Time For assistance with the installation or ongoing use of your solar controller in the first instance please contact Supreme Heating for technical support Alternatively please contact the manufacturer Dontek Electronic Manufacturing Monday Friday 8 30am 5 00pm Phone 03 9762 8800 Melbourne Time For assistance with the installation or ongoing use of your solar pump in the first instance please contact Supreme Heating for technical support Alternatively please contact the manufacturer Astral Pool Australia Hurlcon Monday Friday 8 30am 5 00pm Phone 1300 727 116 Melbourne Time Supreme Heating User Guide Table of Contents Overview Maintenance General Maintenance Vacuum Relief Valve Solar Pump In Line Filter Repair Kit Automatic Solar Controllers Aqua Gen 3 Operating Instructions Aqua Gen 3 BR Operating Instructions N N NN OD DO DOW UN UU A Aqua Gen 3PV Operating Instructions Aqua Gen Troublesho
8. a a U i SSV7RT SSV7RRT Photovoltaic Remote Settings Menu To enter the SETTINGS MENU push either the UP or DOWN buttons and the following will be displayed SETTINGS MENU 1 MANUAL MODE Use UP DOWN buttons to scroll to the option you wish to change Press the ENTER button to select the currently displayed menu item All menu items are shown below SETTINGS MENU 1 Manual Mode 2 Filter Timer 3 Temperature 5 Mode 6 Clock 24h 4 Heat Demand this function is applicable to the SSV7RRT model only 7 Save amp Exit Supreme Heating User Guide 1 Manual Mode MANUAL PUMP MODE UP ON DOWN OFF MANUAL MODE allows you to manually set the aux pump to on by pressing the UP button or off by pressing the DOWN button Pressing ENTER will return you to the SETTINGS MENU You can also keep pressing ENTER to toggle the filter pump from on to off and vice versa MANUAL MODE will time out after 24 hours the controller will return to normal operation 2 Filter Timer SINGLE CYCLE DUAL CYCLE Single cycle sub menu SINGLE CYCLE SINGLE CYCLE START TIME X XX END TIME X XX Dual cycle sub menus FIRST CYCLE FIRST CYCLE SECOND CYCLESECOND CYCLE START TIME X XX END TIME X XX START TIME X XX END TIME X XX When you enter the FILTER SETUP menu you will need to select SINGLE CYCLE or DUAL CYCLE the selected option will be flashing you can use the UP DOWN buttons to change to th
9. ch as chlorinators heaters and in floor cleaning Features Continuous duty rated motor Precision reinforced moulded high head impeller giving extra performance Single piece moulded body for added strength and longer life Rapid priming diffuser quickly corrects loss of water flow Quick and easy disassembly for servicing Large capacity basket with easily removed ramp on lid Operation 1 2 3 Open all valves allowing fluid to flow through pump Switch on power to pump motor to start If some flow of water does not establish within on half a minute switch off and repeat procedure 3 again If pump does not prime within three attempts check all valves and jets are in the open position Note To avoid a safety hazard the supply cord if damaged must only be replaced by Astra Pool Australia Hurlcon or its service agent or a suitably qualified person 20 Supreme Heating User Guide Warranty Agreement Definitions 1 All capitalised expressions used in this warranty are defined in paragraph 17 Warranty 2 Supreme Solar Pty Ltd warrants that its services in installing the Product will be carried out with due care and skill and subject to clauses 3 4 5 and 6 that the installed Product will be free from defects in workmanship for a period of twenty four 24 months after installation warranty includes in field labour costs The warranty is given subject to the terms of this warranty agreement
10. e Apply suitable waterproof grease to the lint pot O ring to ensure positive seal Ensure electrical passage for cooling airflow to prevent fusing or shock hazards Maintain a clear passage for cooling airflow to prevent overheating of motor Maintain water in good chemical balance nu PF Ww N Do not allow quantities of sand or grit to continuously pass through pump to prevent sand blasting erosions use filter sock in lint basket if sand etc is being picked up by vacuum 7 Do not over tighten strainer lid Never use a tool or handle to tighten lid 8 Do not add pool salt chlorine acid or other chemicals directly to your skimmer This may result in damage to your pump and could void your warranty In Line Filter Only applicable on pools with in floor cleaning systems The in line filter should only be installed if your pool has a new or existing in floor cleaning system or where your solar pump is drawing from the skimmer or main drain point at the bottom of your pool This device requires regular maintenance as often as your filter pump or skimmer basket would require cleaning To clean first switch off your filtration Once this is done you can then un screw the main filter bowl of the unit Remove the cartridge filter sock and proceed cleaning with a hose or tap until the filter returns to a white colour In time this item will wear out and will no longer be cleanable Replacements can be found in any
11. e selected option once you select the required cycle by pressing SELECT you will be prompted to set the cycle START TIME and END TIME modify these by pressing the UP DOWN buttons press SELECT to accept the setting SINGLE CYCLE will run the filter pump once per day DUAL CYCLE will run the filter pump twice per day Factory Default is ON DUAL CYCLE from 09 00 to 13 00 and 16 00 to 20 00 Note that the maximum combined rated current is 10 Amps 2400W at 240VAC Supreme Heating User Guide 3 Temperature TEMPERATURE SOL LIMIT XX X When you enter the TEMPERATURE menu you may change the solar heater temperature limit setting SOL LIMIT by pressing the UP DOWN buttons if no change is required simply push ENTER Factory default for SOL LIMIT is 30 C 4 Heat Demand only set ON if auxiliary heating fitted applicable to SSV7RRT model only HEAT DEMAND ON OFF When you enter the HEAT DEMAND you will need to select ON or OFF the selected option will be flashing you can use UP DOWN to change the selected option ENTER to accept If OFF is selected you will return to the menu If ON is selected you will be prompted for START and END time modify values by using the UP DOWN buttons use ENTER to accept the values Factory default is heat demand off HEAT DEMAND TIME HEAT DEMAND TIME START TIME X XX END TIME X XX NOTE If a 24 hour continuous run time is required then set the start time and end time to the same value e
12. equired by Supreme Solar Pty Ltd 14 Purchaser agrees to pursue any claims in relation to defective parts against the manufacturers or suppliers referred to in clause 3 4 and 5 Whole agreement 15 This warranty and any warranties implied by law which are not capable of being excluded or modified from the whole warranty agreement between Supreme Solar Pty Ltd and the Purchaser and all other warranties express or implied whether arising by statute or otherwise are excluded and cancelled Governing law 16 This warranty is governed by the laws of the State specified in paragraph 17 c Defined terms 17 a Purchaser b Product c Governing law paragraph 16 Consumer guarantee The person who has purchased the Product and is able to produce proof of such purchase Supreme Solar Pty Ltd solar pool heating system Victoria Australia 18 This warranty is provided in addition to consumer guarantees and does not alter limit or replace them 24
13. et the controller by turning it off on 6 Maximum rated output load for the 240V socket is 10 Amps 2400 Watt Supreme Heating User Guide Aqua Gen Troubleshooting NO POWER TO THE DISPLAY Power point is faulty test power point with known working appliance if the power point is operational check the controller with another power point and if there is still no display then send the controller for repair PIPE ROOF SENSOR FAULTS The following are error messages caused by pool or roof sensor faults SENSOR DISCONNECTED OR OPEN CIRCUIT Sensor cable unplugged from controller cable damaged bad cable join SENSOR SHORT CIRCUIT OR REVERSED Sensor cable or cable join polarity is incorrect the figure 8 wire has a white stripe to indicate the positive side the positive side of the wire should be wired to the right hand side when viewing the screws with the figure 8 cable entry at the bottom of the plug If the cable has been joined ensure no polarity reversal occurs SENSOR READ ERROR INTERFERENCE Electrical magnetic interference from other equipment is causing errors when trying to read temperature values Ensure sensor wires are located away from mains wiring never cable tie sensors to mains cables Attempt to locate the source of the interference and relocate if possible SENSOR WRITE ERROR CABLE DAMAGED Damaged or kinked cable the sensor at the end of the cable cannot get the power required to perform a temperature
14. force a 3 minute flush if solar has not been active for seven days note the unit may flush if winter mode is selected on the day of install Tropical Mode is selected if you wish to cool the swimming pool the solar pump will run if the roof temperature is colder than the pool until SOL LIMIT is obtained note that this is most likely to occur at night 6 Clock 24h CLOCK 24h CLOCK 24h CLOCK 24h CLOCK 24h SET MINS XX SET HOURS XX SET DATE XX SET MONTH XX When you enter the CLOCK menu you will be prompted to change the MINS settings adjust minutes by pressing the UP DOWN buttons to accept the setting press the ENTER button You will then be prompted to change the HOURS adjust by pressing the UP DOWN buttons to accept the setting press the ENTER button You will then be prompted to change the DATE adjust by pressing the UP DOWN buttons to accept the setting press the ENTER button You will then be prompted to change the MONTH adjust by pressing the UP DOWN buttons to accept the setting press the ENTER button 7 Save amp Exit When this menu is selected push ENTER to save ALL settings the unit will return to normal operation automatically Supreme Heating User Guide Note If any of the menu items are left unattended for 3 4 mins the menu will time out and automatically save all settings and return to operation The Enter button FOR MANUAL MODE PRESS ENTER NOW Pressing the ENTER button once will display
15. g Start 12 00 End 12 00 IF LIMIT ACTIVE SAMPLE AT XXXX Sets the sampling period once the pool has reached the auxiliary temperature limit options are 15 min 30 min 1 hour 2 hours Once the pool reaches the aux temperature limit and the filter pump is turned off it will not be turned on until the sample period expires the filter pump will then run for a minimum period of 3 mins so that water can flow past the pool temperature sensor and obtain an accurate reading Should heating be required the filter pump will remain on to heat the pool Factory default for HEAT DEMAND is OFF 06 00 to 22 00 sample 1 hour Supreme Heating User Guide 5 Mode MODE SUMMER MODE WINTER MODE TROPICAL MODE You can use UP DOWN to change the selected option ENTER to accept Summer Mode is the normal operation of heating the swimming pool Winter Mode when selected you will be prompted to select the start month and end month of winter inclusive this assists in the systems off season maintenance and saves energy as solar gain may be available but swimming temperature cannot be achieved If heat demand is set to OFF a 3 minute flush of the solar matting occurs between 10 00 and 16 00 providing the roof temperature is equal or greater than the pool but if that condition does not occur a solar system flush will be forced to occur at 16 00 If heat demand is ON the system operates similar to normal mode but solar pump activity is monitored and will
16. her than the defaults may adversely affect the performance of this controller To select these features hold the DOWN button then press SELECT When you select this option you will be prompted to set the solar gain start temperature RUN x this setting allows the pump to start if the roof temperature exceeds the pipe temperature by this value adjust with the UP DOWN button press Supreme Heating User Guide SELECT to accept Next you will be prompted to set the differential hysteresis END x which turns the pump off when roof temperature is less than the pipe temperature plus this value adjust with the UP DOWN button press SELECT to accept Default values are 8 for RUN and 4 for END these are the optimal values for maximum efficiency some coastal locations may benefit from a reduced run value of 6 C for RUN and 4 C for END Next is anti freeze this function is applicable to Aqua Gen 3 amp Aqua Gen 3BR models only you will be prompted by FRZ ON OFF adjust with the UP DOWN button press SELECT to accept If you select OFF then all the above settings will be saved and the unit will restart If you selected ON then you will be prompted to adjust the anti freeze start temperature point as follows FREEZ x adjust with the UP DOWN button press SELECT to accept Once the roof temperature gets to the anti freeze setting or below then the pump will be turned on for 3 minutes then turn off for 30 minutes this sequence will
17. ifolds The valve provides vacuum relief when the solar pump turns off by allowing the water to drain back to the pool Air is drawn into the system through the top of the valve due to gravitational forces opening the internal seal When the pump turns on water pressure will re seal the vacuum relief valve Air should be expelled into the pool within 2 3 minutes depending on the size of the system and during this period the resulting turbulence created will cause some associated noise Vacuum relief valves should be inspected regularly 2 4 weeks during the months of E operation If it is leaking or blocked no surges of air returning to pool it should be cleaned This can be done by pulling the cap off the top of the valve Remove visible obstructions and wash the components with water The solar pump must be turned off before cleaning commences Failure to correctly install a vacuum relief valve in your system or inspect and maintain its operation will void all warranties related to collectors pipe work and fittings Supreme Heating User Guide Solar Pump The SS amp FX series solar pumps are designed to operate for extended periods without any attention or maintenance Following are the periodic maintenance requirements 1 Keep lint basket clean empty it regularly Blocked lint basket or suction pipe and no water flow can cause overheating with consequent pipe and pump components failure and meltdown if applicabl
18. ii the payment of the cost of having the services supplied again What Supreme Solar Pty Ltd will do 10 For defects relating to installation of the Product Supreme Solar Pty Ltd will in its absolute discretion a repair the Product or pay for the cost of having the Product repaired or b replace the Product or supply an equivalent Product or c pay for the cost of replacing the Product or acquiring and equivalent Product if the terms and conditions of this warranty are satisfied Supreme Solar Pty Ltd will not be liable for any other loss or damage including consequential or indirect damages Supreme Solar Pty Ltd reserves the right to charge the Purchaser at Supreme Solar Pty Ltd s current hourly rate for the cost of examining the Product if such examination by Supreme Solar Pty Ltd reveals that the Product a is not defective or b is defective as a result of any of the events specified in paragraph 7 What the Purchaser must do 12 Any claim under this warranty must be made at the earliest stage that the defect becomes obvious to enable prompt action and to avoid further damage and must be made no later than one 1 month of the defect becoming obvious 23 Supreme Heating User Guide 13 Any claim for warranty must be accompanied by appropriate documentation which stipulates the date of installation the invoice number the details of the alleged defect and any other information reasonably r
19. local pool shop or are available at Supreme Heating Repair Kit Repair kits are provided for the traditional strip solar systems so that minor damage to the solar collectors can very easily be repaired by the home owner Please contact Supreme Heating for authorisation and further advice or instruction Supreme Heating User Guide Automatic Solar Controllers Supreme Heating has combined the latest technology together with user friendly concepts in the development of our extensive range of automatic solar controllers Our range of solar controllers are digitally controlled and are also available with optional wireless roof sensors These are used to control the heating of your pool and or spa from your solar collector To determine what controller you have please refer to your quotation invoice or model number which can be found near the display screen of the unit Aqua Gen 3 Operating Instructions The Aqua Gen 3 is a premium automatic solar controller with temperature adjustment manual winter and tropical mode features All configurable items are retained after a power outage for up to 14 days Aqua Gen 3 Aqua Gen 3BR Aqua Gen 3PV Battery Remote Photovoltaic Remote Temperature Limit To adjust the pool limit simply press the UP button to increase or the DOWN button to decrease the desired temperature The controller will automatically choose to run the pump based on solar gain i e sun shining amp roof is
20. n power to pump motor to start 4 If some flow of water does not establish within on half a minute switch off and prime pump again If pump does not prime within three attempts check all suction connections for sealing If these are satisfactory a check or foot valve is required to hold water for prime 5 If the water flow through pump is always tedious to obtain at start up after cleaning the lint basket then an examination of the system to establish a reason and correct the cause is recommended eg Check valve air leaks faulty seal cracked lint pot lid etc 6 The non return valve is supplied loose in the basket of pump To install place between the outlet barrel union tail and the discharge of the pump The non return valve should be located so that the Supreme Heating User Guide flap can swing upwards into the union tail The non return valve should be installed on spas equipped with cartridge filters any time multiple pumps are operating off one suction or return line or any installation where a back flow of water may occur when the pump is shut down The non return valve will reduce the performance of the pump slightly Note To avoid a safety hazard the supply cord if damaged must only be replaced by Astra Pool Australia Hurlcon or its service agent or a suitably qualified person FX Series Solar Pump A high performance high head pump ideally suited for the modern pool or spa with extensive equipment su
21. n winter mode or for manual mode operation If the controller reports that the pump is off then press select to enable manual mode the relay inside should click and the pump should operate If the pump does not operate then plug the pump into a power point and test operation if the pump is OK then the controller requires repair PUMP WILL NOT STOP Turn off power to the controller ensure the pump stops if the pump continues to operate then unplug it from the power point and connect it to the 240Vac socket marked PUMP at the bottom of the controller Apply power to the controller and if the pump starts instantaneously before temperatures are displayed then the may be a fault with the controller since the controller shouldn t run when there is a sensor fault disconnect the roof sensor and wait for approximately 30 seconds if the pump continues to run then the controller requires repair POOL NOT HEATING If the controller has stopped pumping and is displaying a higher temperature than expected it may be caused by a pump which is failing to prime check the pump and if necessary prime the pump as per the pump manufacturers instructions then reset the controller by turning it off on Supreme Heating User Guide SSV7RT Operating Instructions The SSV7RT is a premium automatic solar controller with temperature adjustment manual winter and AUN A CULTURE tropical mode features _ ey SS ae B TR
22. oin SENSOR SHORT CIRCUIT OR REVERSED Sensor cable or cable join polarity is incorrect the figure 8 wire has a white stripe to indicate the positive side the positive side of the wire should be wired to the right hand side when viewing the screws with the figure 8 cable entry at the bottom of the plug If the cable has been joined ensure no polarity reversal occurs ISOLATING SENSOR FAULTS Swap the sensor locations simply put the pipe sensor in the roof socket and the roof sensor in the pipe socket If the fault moves from pipe to roof or vice versa then you can be certain that there is a sensor fault If the fault remains the same then the controller will need repairs For sensor open circuit faults check for damage to the cable and repair if required If no damage can be found replace the sensor If the cable runs underground or inspection is not possible then cut the sensor from near the end of the cable and strip back the wires and join them if the controller reports a short circuit then the cable is fine and you may replace the sensor end if re routing a new cable is not possible For sensor short circuits if the controller reports an open circuit when the cable is unplugged then attempt reversing the cable polarity replace the sensor if reversal is unsuccessful then the controller requires repair if the controller reports a short circuit while the cable is unplugged then the controller requires repair Supreme Heating User G
23. oting _ oO _ N SSV7RT Operating Instructions _ N SSV7RRT Operating Instructions SSV7 Troubleshooting N O Solar Pumps _ Ko SS Series Operating Instructions N oO FX Series Operating Instructions Warranty Agreement N Supreme Heating User Guide This manual contains information about the operation and warranty terms and conditions of our solar pool heating systems Also included is advice on how to maintain and diagnose problems with your solar pool heating Please read operating instructions carefully before using appliances The equipment is not intended for use by young children or infirm persons without supervision Please ensure young children are supervised to ensure they do not play with the equipment Overview Solar heating installed on a pool will give you a swimming season of 6 9 months depending on where you are situated in Australia This is approximately double an unheated pool swimming season The pool is heated by circulating water through the solar collector where it absorbs the suns energy Solar systems normally incorporate a separate pump and automatic controller to maximise heat gain and can be fitted to existing pools With proper maintenance your solar pool heating system should provide many years of trouble free service Features e Higher efficiency to allow optimum heat gain e Quality products for added strength and durability
24. reading Replace cable and or sensor ISOLATING SENSOR FAULTS Swap the sensor locations simply put the pipe sensor in the roof socket and the roof sensor in the pipe socket If the fault moves from pipe to roof or vice versa then you can be certain that there is a sensor fault If the fault remains the same then the controller will need repairs For sensor open circuit or write error faults check for damage to the cable and repair if required If no damage can be found replace the sensor If the cable runs underground or inspection is not possible then cut the sensor from near the end of the cable and strip back the wires and join them if the controller reports a short circuit then the cable is fine and you may replace the sensor end if re routing a new cable is not possible For sensor short circuits if the controller reports an open circuit when the cable is unplugged then attempt reversing the cable polarity replace the sensor if reversal is unsuccessful then the controller 10 Supreme Heating User Guide requires repair if the controller reports a short circuit while the cable is unplugged then the controller requires repair PUMP FAULTS Ensure the controller has working sensors otherwise the pump will not operate PUMP WILL NOT START The pump will only ever run for the purpose of automatic heating if the pool is below the temperature limit and solar conditions can provide heating The pump may also run for a flush i
25. rranty temperature sensors not covered from Dontek Electronics Pty Ltd 19 Melrich Road Bayswater Victoria 3153 Phone 03 9762 8800 Email service dontekelectronics com au or b in the case of a Aqua Gen 2 Automatic Controller a two 2 year limited warranty temperature sensors not covered from Dontek Electronics Pty Ltd 19 Melrich Road Bayswater Victoria 3153 Phone 03 9762 8800 Email service dontekelectronics com au and is the only warranty given in respect of that part of the Product 5 The Solar Pump included in the Product carries a three 3 year limited warranty six 6 months for commercial installations from Astral Pool Australia Pty Ltd 48 Hanna Street Noble Park Victoria 3174 Phone 03 9554 2200 Email melbourne astralpool com au and is the only warranty given in respect of that part of the Product In field labour warranty is applicable in Capital City Metropolitan areas or within a 20km radius of an Authorised Astra Pool Australia Service Agent 6 All other components supplied by Supreme Solar Pty Ltd carry a twelve 12 month limited warranty and is the only warranty given in respect of these components of the Product Exclusions 7 Supreme Solar Pty Ltd will not be liable under this warranty where Supreme Solar Pty Ltd s reasonable opinion a defect is caused by a fair wear and tear b negligent careless or improper use or handling c non adherence to operating cleaning or maintenance in
26. structions d harsh or adverse Pool Spa water conditions e repair to or alteration of any parts of the system by any person who has not been authorised by Supreme Solar Pty Ltd to perform such a repair or alteration f act of God riot fire or other occurrence outside normal working conditions or g by other abuse or misuse caused by the Purchaser or a third party 8 Subject to clause 9 any condition or warranty which would otherwise be implied in this agreement or in relation to the Product is hereby excluded 22 Supreme Heating User Guide Where legislation implies in this agreement or in relation to the Product any condition or warranty and that legislation avoids or prohibits provisions in a contract excluding or modifying the application of or exercise of or liability under such condition or warranty the condition or warranty shall be deemed to be included in this agreement However the liability of Supreme Solar Pty Ltd for any breach of such condition or warranty shall be subject to clause 14 and any other applicable exclusions set out in this agreement be limited at the option of Supreme Solar Pty Ltd to one or more of the following a if the breach relates to goods i the replacement of the goods or the supply of equivalent goods ii the repair of such goods iii the payment of the cost of having the goods repaired and b if the breach relates to services i the supplying of the services again or
27. the above message for approximately 3 seconds simply wait and the unit will return to normal operation If the ENTER button is pressed for a second time within a 3 second period the display will indicate you have entered Manual mode operation is the same as manual mode in the menu with the only difference being the timeout value is 4 hours Notes 1 Ifa sensor fault is detected the SSV7RT will display which sensor and what the fault is 2 Should power be interrupted for any reason the SSV7RT will resume normal operation when power is restored all information will have been kept 3 Temperature sensors used with this unit are digital and are accurate to 0 5 C no calibration is required 4 The sensor cable with the thin trace is the positive and is usually fitted to the right hand side of the green plug incorrect polarity will be displayed 5 Solar start and end times may be changed by holding the up button while power is applied Supreme Heating User Guide SSV7 Troubleshooting NO POWER TO THE DISPLAY Power point is faulty test power point with known working appliance if the power point is operational check the controller with another power point and if there is still no display then send the controller for repair PIPE ROOF SENSOR FAULTS The following are error messages caused by pool or roof sensor faults SENSOR DISCONNECTED OR OPEN CIRCUIT Sensor cable unplugged from controller cable damaged bad cable j
28. uide PUMP FAULTS Ensure the controller has working sensors otherwise the pump will not operate PUMP WILL NOT START The solar pump will only ever run for the purpose of automatic heating if the pool is below the temperature limit and solar conditions can provide heating The solar pump may also run for a flush in winter mode and the auxiliary pump can be activated by running the manual mode operation The best method for testing the operation of the pump s is to enter the settings menu and select winter mode save and exit out of the settings menu to return to automatic operation and the unit will test the temperatures then it will activate the auxiliary pump for 3 minutes followed by the solar pump for 3 minutes Note that the roof temperature must be greater than the pool temperature and the time must be between 10am and 4pm PUMP WILL NOT STOP Turn off power to the controller ensure the pump stops if the pump continues to operate then unplug it from the power point and connect it to the 240Vac socket marked PUMP at the bottom of the controller Apply power to the controller and if the pump starts instantaneously before temperatures are displayed then the may be a fault with the controller since the controller shouldn t run when there is a sensor fault disconnect the roof sensor and wait for approximately 30 seconds if the pump continues to run then the controller requires repair POOL NOT HEATING If the controller has stopped