1. 5 Maintenance And Troubleshooting This chapter describes the maintenance and troubleshooting procedures for the DDU 2300 AED The self tests that are performed by the device are described along with the frequency and nature of routine maintenance for which the owner operator is responsible A troubleshooting guide is provided to help diagnose user serviceable problems The DDU 2300 AED contains no user serviceable parts Routine Unit Maintenance Although the DDU 2300 AED is designed to be very low maintenance simple maintenance tasks must be performed by the owner operator on a regular basis to ensure the unit s dependability Check that the Active Status Indicator ASI is flashing green Check the condition of the unit and accessories Run manually initiated self test Replace pads Check pad and battery pack expiration dates Check the DDC card if one was installed Note f the unit has been dropped mishandled or abused a manually initiated self test should be performed Checking The Active Status Indicator The Active Status Indicator ASI is located to the right of the ON OFF button of the DDU 2300 AED and indicates the operational readiness state of the unit The ASI will periodically flash green to indicate that the unit is ready for use Ready for use means that the DDU 2300 has passed the most recent self test scheduled or user initiated If it is flashing red solid red or not flashing at a
2. ll the AED needs service Anytime the ASI is flashing red the unit will periodically emit two beeps to call attention to it If the ASI is not flashing at all the most likely cause is that the battery pack needs to be replaced Refer to the Installing And Removing The Battery Pack section in Chapter 3 of this manual Once the battery pack has been replaced with a fresh battery pack the ASI should once again flash green If it still does not flash green after inserting a new battery pack the DDU 2300 AED is non operational and may need servicing Call Defibtech for service Refer to the Contacts section in Chapter 12 of this manual If the ASI is flashing red turn the DDU 2300 AED on If the unit does not turn on or does not speak the AED is non operational and requires servicing If the unit does turn on then turn the unit off and the voice prompts will indicate the nature of the problem Flashing Green DDU 2300 AED is OFF and ready for use Solid Green DDU 2300 AED is ON and ready for use Flashing or Solid Red DDU 2300 AED needs immediate service Refer to the Troubleshooting section in Chapter 5 of this manual or call Defibtech for service Active No Flashing Light DDU 2300 AED needs immediate service Refer to the Status Troubleshooting section in Chapter 5 of this manual or call Defibtech for service Indicator 5 1 DAC 2513EN AB
Download Pdf Manuals
Related Search
Related Contents
ZS640P/ZS970P Zylinderschleifmaschine Mini wide belt sander USER MANUAL - Kramer Electronics Manual de Instalação Dräger X-am 5600 Sandisk Sansa Clip+, 4GB BTL6 A/C/E/G500 M _ _ _ _ PF S115 User`s Guide PortaBilling: User Manual Cirkuit Planet Nightmare Before Christmas, 4GB Manuel d`utilisation n°10 Copyright © All rights reserved.
Failed to retrieve file