Home

1620 Digital BABY SCALE OPERATING INSTRUCTIONS

image

Contents

1. IMMEDIATELY SEE A DOCTOR KEEP BATTERIES OUT OF REACH OF CHILDREN Dispose of batteries immediately and responsibly Made in China for Propert Housewares A division of SUPERTEX INDUSTRIES PTY LTD a wholly owned Australian company N2853 ABN 85 003 833 029 For further information website www supertex com dqu Email customerservice supertex com dau Telephone 02 8756 3000 Facsimile 02 9748 6622 a AFTER SALES SERVICE a S TEL 1300 470 038 PLEAGE DO NOT sated A signatory to the Australian Packaging Covenant V2 1305 AUSTRALIA 13 1126 NEW ZEALAND 0800 764 766 propert 20kg digital baby scale In your home since 1920 Model 1620 Operating Instructions AFTER SALES SERVICE TEL 1300 470 038 OPERATING INSTRUCTIONS some assembly required Please read the instructions carefully to ensure the correct operation of the scale Retain these instructions for future reference Before using the Propert Digital Baby Scale remove all packaging Applications e Use with the cradle for weighing baby e Remove the cradle to use as a stand on scale for young children up to 20kg Scale components 1 x scale 1 x cradle 2 x screws Preparing your scale Purchase four AA 1 5volt alkaline batteries and insert in the battery compartment underneath the scale Make sure the positive and negative terminals are correctly positioned Then replace the battery cove
2. Care for your scale 1 Clean the scale with a damp soft cloth using a mild detergent or non cabrasive household cleaner but do not allow water to get inside the scale as this could damage the electronics 2 Toclean the cradle thoroughly detach it first then wash with warm soapy water rinse and dry 3 Should the scale malfunction do not dismantle or try to fix it Refer to your Warranty details 4 Remove the batteries if the scale is not being used for a long period of time 5 Handle the scale with care Do not allow it to be Jumped or pounded on Hints on Using Baby Scales Moving the scale around frequently may affect its accuracy so if possible try to leave it in a permanent position that has a frm and even surface If placing on a table or benchtop make sure it is safely away from the edge After moving it ensure it shows zero correctly before using it again Body weight varies with a number of factors including the amount of food recently eaten the amount of waste recently expelled by the body physical activity and of course the clothing worn by baby If possible try to weigh baby at the same time of day under the same conditions and with the same clothes on or preferably no clothes on This will reduce the chance of getting unexplained variations in weight Do not try to compare baby s weight on a number of scales You may find you get different readings which can be frustrating and confusing The diff
3. erences could be due to some scales being slightly inaccurate and or baby s body weight varying due to one or more of the factors mentioned above Even if a scale appears slightly inaccurate it will normally give you an accurate measurement of the variance in the weight from the previous times you weighed the baby If you regularly use the same scale under the same conditions it should monitor changes in baby s weight accurately Specifications Capacity 20kg 44lb Graduation 5g 0 0051b Weighs in kilograms or pounds Detachable cradle Large LCD viewing size 93 x 33mm Non slip ribbed mat Tare memory and recall functions Automatic off function and zero resetting Low battery and overload indicators Powered by 4 x AA batteries not included Equipped with high precision strain gauge sensors BATTERY WARNING e Different types of batteries or old and new batteries are not to be mixed z Only batteries of the Emergency Telephone Numbers same or equivalent AUSTRALIA 000 NEW ZEALAND 111 type are to be used Poisons Information Centre e Batteries are to be inserted with the correct polarity e Remove exhausted batteries from the product e Donot short circuit the battery terminals e Never throw batteries in a fire or attempt to open up their outer casing BATTERY WARNING INTERNAL BURNS CHOKING HAZARD Swallowing batteries may lead to serious injury or death severe burns can occur within 2 hours
4. r aides as the nght way Sa up and firmly attach the cradle to the scale base using the SCrewsS Back view supplied Ensure the rear of cradle is securely hinged onto the catch at the back of the scale first Button functions ON TARE Power button to turn on and off Tare weigh function Unit selection Toggles between UNIT kilograms and pounds Save and recall weight value 3 1 Place the Digital Baby Scale on a firm and even surface Use on soft or uneven surfaces may result in inaccurate readings If placing on a benchtop ensure that it is away from the edge for safety 2 Activate the scale by pressing the power button It is ready for use when the display ZETOSS 3 You may if you wish toggle between kg or lb by pressing the UNIT button 4 Gently place baby on the scale for a weight reading 5 The display flashes baby s weight 6 Press MEM if you wish to save this reading 7 To turn the scale off manually make sure you are in weighing mode Then press ON TARE and hold for 3 seconds If left idle the scale will automatically turn off after about 5 minutes Memory function This option allows you to save and then recall baby s current weight A new weight value saved will override the previous one 1 To recall baby s previous weight turn the scale on and when it zeroes press MEM 2 MEM appears on the screen as a reminder that you are in memo
5. ry mode 3 To exit memory function press MEM Tare Weigh Function l If you wish to place a towel or blanket on the scale for baby to lie on do this first before activating the scale 2 When it zeroes gently place baby in the cradle The readout will exclude the weight of the blanket or towel and give baby s actual weight Overloading If the scale is overloaded exceeding 20kg 441b o Ld will display Remove the weight immediately to prevent damage Low battery indicator Replace the batteries when Lo is displayed Always use new fresh Alkaline batteries Automatic off function If left idle the scale will automatically turn off after about 5 minutes Using as a stand on scale This is useful for young children Detach and remove the cradle by undoing the screws Remember to safe keep the screws for future use 1 Place the scale on a firm and even surface Use on uneven or soft surfaces like carpet may result in inaccurate readings 2 Gently stand the child on the scale Ensure the child s feet are placed evenly on the platform and that he she is standing perfectly still Movement leaning backward or forward will affect the accuracy of the weight displayed 3 Use the scale as you would with the cradle on

Download Pdf Manuals

image

Related Search

Related Contents

USER`S MANUAL - UltraPower Technology  低振動! - ゼノア  Tandem two-step purification using ÄKTA™ pure or ÄKTA avant  Fisher-Price T4265 Instruction Sheet    AIRLESS FILM FAULTS – TROUBLESHOOTING  カタチ新発見! 立体ピクロス2  VMB1TS  Broilmaster P4 User's Manual  事 業 者 排 出 量 削 減 計 画 書  

Copyright © All rights reserved.
Failed to retrieve file