Home

Operating Instructions On/Off Select the ON/OFF button to switch

image

Contents

1. modify parts of the controller the high voltage might cause danger All the maintenance and repairing should be carried our by qualified personal Special Statements 1 The product must be repaired by the manufacturer of the controller or qualified servicemen authorized by its agents if necessary otherwise the product is not allowed to be warranted and all lose caused thereof are not assumed by our company 2 The instruction manual is only for reference and all designs and descriptions included herein are subject to change and update without prior notice The manufacturer has the sole right to interpret any ambiguity error or missing in the instruction manual if existed For any consequences caused by wrong operation the user should bear the responsibility Programming the Control System To Change Program To switch between programs Press the following buttons in sequence HEAT PUMP1 PUMP2 BLOWER PUMP3 The control panel will show 1 2 or 3 you can cycle through 1 Program A 2 Program B and 3 Program C Details of Programs Program A water pump 1 water pump 2 water pump 3 air pump and heater can all operate at the same time Program B water pump 1 water pump 2 and air pump can turn on at the same time But when water pump 1 water pump 2 or air pump is turned on water pump 3 cannot run But when the heater is turned on the water pump 1 water p
2. Operating Instructions On Off o Select the ON OFF button to switch your hot tub on and press again to return back your hot tub back to standby mode Operation of Water Pumps There are three buttons to control the water pumps the water level must be of a certain level before they operate Pressing any of the 3 pumps buttons will switch on the pump and the associated pump icon will appear on the display pressing the pump button again will switch off the pump Pump 2 if fitted Pump 3 Circulation pump If the water level is not sufficient when operating any of the pumps then the appropriate pump icon will flash Ozone Ea runs the ozone generator When running the Ozone icon will appear in the display To switch off just press the ozone button once more NB Ozone sterilisation will switch off automatically after 10 minutes lower DOn button operates the air blower if fitted The blower will only run when the water level has been detected to be over the required level When running the blower icon will appear in the display To turn off just press the blower button again If there is not sufficient water in the hot tub the blower icon will flash fa operate the hot tub light press this button when pressed the lightbulb symbol will appear on the display To switch off the light press the light button again If your hot tub is fitted with the perimeter LED light option this button will also operate the perime
3. ermostatically controlled There must be sufficient water in the hot tub for the heating and filtering to work correctly heat your hot tub press the HEAT button to turn on the heating The heater icon will start flashing and Pump 3 will first start running and display and also the Pump 3 icon This pump must be running during heating to circulate the water through the hot tub After 10 seconds the heat icon will stop flashing on the display indicator the heating has started Pressing the Heat button again will switch off the heater and the circulation pump will stop running 10 seconds after NB if you press Pump 3 whilst the hot tub is heating this will override the automatic feature so when the temperature reaches temperature the heating will stop but the circulation pump will continue to operate To adjust the temperature of your hot tub press the FUN button the temperature display will now flash Use the TUN and TUN buttons to adjust the heat The default temperature is 37c 99f temperature range is from 30c to 42c 86f 108f Once the hot tub has reached the required temperature the heating will automatically shut down until the temperature drops below the preset temperature at that point heating will automatically restart Freeze Protection If it is detected that the water temperature drops below 5c the heating will automatically be turned on until the water temperature reaches 9c Setting the Pre Heat Cycle This function allow
4. g the filtration cycle To switch the filtration cycle off press the CYCLE SET button again Leaving the panel for a short time and the display will return to standby and Pump 3 icon will flash To switch off the filtration cycle when the hot tub is in standby mode press the CYCLE SET button and C OFF will be displayed If filtration cycle is off then the filtration will automatically run every 6 hours if ozone if fitted then this will operate also Radio CD Operation Your hot tub has a FM radio and auxiliary CD MP3 control built into the control panel The FM CD button controls the Radio and CD functions pressing the FM CD button with cycle through the FM radio gt CD input gt Off fre Use the TUN and TUN buttons to tune the radio to the desired frequency Volume Press the FUN button and the volume value in the display will flash Then use the TUN and TUN to adjust the volume Selecting a Preset Radio Station Press the MEM button to cycle through the preset radio frequencies Storing Radio Channels in Memory Once the desired frequency has been tuned press and hold the MEM button for 2 seconds until a beep is heard and the memory preset number flashes Press MEM to cycle through the preset buttons until the required preset number is displayed Then press and hold the MEM button again to store the frequency a beep will be heard and the station is now set Operation of Remote Control 1 Any functional button of
5. s for the heating cycle to be switched on at a predetermined time fa Press the HEAT SET button when your hot tub is in standby mode H ON Will be displayed The time will flash adjust this using the TUN and TUN buttons to set the time you wish the hot tub to heat from Then press the FUN button you can now set the duration you wish the hot tub to heat for using the TUN and TUN from 10 minutes to 23 hours and 59 minutes Finally press the FUN button again to set the temperature you wish the hot tub to heat to Leaving the panel for a short time and the display will return to standby and heater icon will flash To switch the heat cycle off press the HEAT SET button again and H OFF will display Setting the Filtration Cycle This function allows the water filtration cycle to operate automatically you can set what time and the duration you wish the hot tub to cycle for ar Press the CYCLE SET button when the hot tub is in standby mode The panel will display C ON indicating that filtration cycle has been switch on The time will flash to allow you to enter what time you wish the cycle to start adjust this using the TUN and TUN buttons to set the time Then press the FUN button you can now set the duration you wish the hot tub to cycle for up to 30 minutes using the TUN and TUN buttons to increase and decrease the minutes Pressing the Ozone button will also select whether you wish the ozone sterilisation to run durin
6. ter lights To change the setting colour of the light switch the lights off then back on and this will cycle through the different colours and settings available Warning If you hot tub is fitted with perimeter LED lights some of the lighting options are not suitable for people with photosensitive epilepsy A very small percentage of individuals may experience epileptic seizures when exposed to certain light patterns or flashing lights Certain conditions may induce previously undetected epileptic symptoms even in persons who have no history of prior seizures or epilepsy This alternates the temperature display between Fahrenheit and centigrade Locking Unlocking you tub This button will operate the panel lock so none of the other buttons can accidentally be pressed To lock your hot tub press the LOCKED button the padlock icon will display in the control panel and this will lock the controls from accidentally being pressed to unlock your hot tub press and hold the LOCKED button until the controls are released NB If no activity is reported on the control panel for 30 minutes the panel will automatically lock Setting the Clock To set the clock on your hot tub press the CLOCK button the time display will now flash press TUN to adjust the hour and press TUN to adjust the minutes Once set leave the control panel for a short time for it to let the time display stop flashing the time is now set Setting the Heat Your hot tub is th
7. the system works with a beep sound accompanied by the buzzer 2 The functional buttons on the remote controller have the same operation methods with the corresponding functional buttons on the button panel Specifications 1 Rated voltage AC220V 2 Working voltage range AC180V AC248V 3 Rated power 50Hz 4 Controllable current lt 55A 5 Power consumption lt 10W all loads OFF 6 Applied ambient temperature 5 C 40 C 7 Sensitivity to the noise limit of the radio 20 dBuv 8 Step down transformer meeting the requirements of 1500V high voltage test as specified by IEC standard Controlled devices 1 Water pump AC220V 3HP 2 Air blower AC220V 1 25HP 3 Thermostatic heater 1 AC220V 3KW 5KW 4 Ozone AC12V 15W 5 Underwater lamp gt AC12V 20W Precautions for Installation and Use In order to guarantee the products function prolong its lifetime and ensure the safety during using please read the following items carefully before using 1 The power cable cannot be used until it is checked carefully and and quality is confirmed 2 The end user should not connect unqualified electrical appliances to the controller Disassembling or modifying any connecters in the controller is prohibited 3 The connection wire of power box should be wired according to the specification 4 The installation of the hot tub should be carried out by qualified personal according to the installation manual 5 Do not try to repair or
8. ump 2 water pump 3 and air pump switch off Program C water pump 1 water pump 2 water pump 3 air pump and heater can run at the same time When the heater is turned on water pump 1 water pump 2 water pump 3 and air pump switch off

Download Pdf Manuals

image

Related Search

Related Contents

Thecus N7700PRO v2  StarTech.com 24 Port 0.5U Cat5e Patch Panel - RJ45 Ethernet Rackmount Cat 5e 110 Patch Panel  Novell® Sentinel  MUSTANG Betriebshandbuch Seite 2 – 12 Manuel d'utilisation Page  Senco PC1130 User's Manual  Samsung WF0600NXW Uživatelská přiručka  Epic Fitness ADJUSTABLE BENCH strength bench 2003 User's Manual  