Home

< ,ϭϮWKZ USER MANUAL

image

Contents

1. INSTALLATION INSTRUCTIONS Remove the drain plug Fig 23 Continuous drain hose Fig 24 Fig 25 Water drainage During dehumidifying modes remove the drain plug from the back of the unit install the drain connector 5 8 universal female mender with 3 4 hose locally purchased For the models without drain connector just attach the drain hose to the hole Place the open end of the hose directly over the drain area in your basement floor Please refer to Fig 23 amp 24 When the water level of the bottom tray reaches a predetermined level the unit beeps 8 times the digital display area shows P1 At this time the air conditioning dehumidification process will immediately stop However the fan motor will continue to operate this is normal Carefully move the unit to a drain location remove the bottom drain plug and let the water drain away Fig 25 Restart the machine until the P1 symbol disappears If the error repeats call for service Air filter slide out Fig 26 Remove three Screws and take the air intake grille down Fig 27 Remove the air filter 28 out from the grille 19 Fig 30 CARE AND MAINTENANCE CARE AND MAINTENANCE IMPORTANT 1 Be sure to unplug the unit before cleaning or servicing 2 Do not use gasoline thinner or other chemicals to clean the
2. ONTENTS CCC L L SOCIABLE REMARK OCIS o o 2 SAFETY PRECAUTIONS Safety leS A SER EDS Operating condition Electrical information IDENTIFICATION OF PARTS Accessories Names of part AIR CONDITIONER FEATURES Electronic control operating instructions si seniorer niei rE anie EE EEEN EEEREN 6 OPERATING INSTRUCTIONS Operating INSIUCIONS ssec ooo eI od en ee 7 INSTALLATION INSTRUCTIONS kocation nase A E 9 Window kit installation Exhaust hose installation zs Water drenado vaticina 13 CARE AND MAINTENANCE Laresand Maintenante a 14 TROUBLESHOOTING TIPS Trouble sh ting e enec 15 NOTE The rating data indicated on the energy label is based on the testing condition of installing the un extended air exhaust duct without adaptor A amp B The duct and the adaptor A amp B are listed in the accessories chart of the Instruction Manual SOCIABLE REMARK When using this air conditioner in the European countries the following informa tion must be followed DISPOSAL Do not dispose this product as unsorted municipal waste Collection of such waste separately for special treatment is necessary It is prohibited to dispose of this appliance in domestic household waste For disposal there are several possibilities A The municipality has established collection systems where electronic waste can be disposed
3. Turn off the product when not in use e Always contact a qualified person to carry out repairs If the supply cord is damaged it must be repaired by a qualified repairer e Keep an air path of at least 30cm all around the unit from walls furniture and curtains If the air conditioner is knocked over during use turn off the unit and unplug from the mains supply that it is protected from moisture e g condensation such as a bathroom or laundry room Do not touch the unit with wet or damp hands or when barefoot Do not press the buttons on the control panel with anything other than your fingers e Do not remove any fixed covers Never use this appliance if it is not working properly or if it has been dropped or damaged Never use the plug to start and stop the unit Always use the switch on the control panel Do not cover or obsturct the inlet or outlet grilles Do not use hazardous chemicals to clean or come into contact with the unit Do not use the unit in the presence of inflammable substances or vapour such as alcohol insecticides petrol etc Do not allow children to operate the unit 4 WARNING Electrical Information e Be sure the electrical service is adequate for the model you have chosen This information can be found on the serial plate which is located on the side of the cabinet and behind the grille Be sure the air conditioner is properly grounded To minimize shock and fire hazards
4. move the louver to the desired position 2 If keep pressing the SWING button without releasing for 2 more seconds the auto swing feature of the louver is activated The horizontal louver would swing up down automatically Press it again to stop NOTE When the louver swing or move toa position which would affect the cooling and heating effect of the air conditioner it would automatically change the swing moving direction E y SET TEMPERATURE C MODE ON OFF FAN SPEED SWING ECONOMY TIMER ON reserock TIMER OFF LED DISPLAY Timer operation press the TIMER ON button can set the auto on time of the unit And press the TIMER OFF button can set the auto off time of the unit To set the Auto on time 1 Press the TIMER ON button The remote controller shows TIMER ON the last Auto on setting time and the signal h will be shown on the LCD display area Now it is ready to reset the Auto on time to START the operation 2 Push the TIMER ON button again to set desired Auto on time Each time you press the button the time increases in 30 minutes increments up to 10 hours then at 1 hour increments up to 24 hours 90 CO a After setting the TIMER ON there will be a one half second delay before the remote controller transmits the signal to the air conditioner Then after approximately another 2 seconds the signal h will disappear and the set temperature will re appear on
5. proper grounding is important The power cord is equipped with a three prong grounding plug for protection against shock hazards Your air conditioner must be used in a properly grounded wall receptacle If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker have a qualified electrician install the proper receptacle Ensure the receptacle is accessible after the unit installation immediately unsupervised Accessories Do not use this product for functions other than C those described in this instruction manual PARTS PARTS NAME QUANTITY Energy Save qi E Exhaust hose and adaptor 1 supplied 1 set Use the unit in the recommended room size or adaptor B round He OO 9 LO on models and Win X Adaptor B round mouth iX 1 set e Locate the unit where furniture cannot obstruct the air flow e Keep blinds curtains closed during the sunniest part of the day Keep the filters clean Keep doors and windows closed to keep cool air in and warm air out Operating condition 9 The air conditioner must be operated within the temperature range indicated below Wall Exhaust Adaptor A X 1 pc MODE ROOM TEMPERATURE Expansion Plug and wooden screw X 4 pc COOL 17 C 62 F 35 C 95 F 109 oam seal X 3 pc DRY 13 C 55 F 35 C 95 F 5 m Remote Contro
6. fan speed FAN operation Press the MODE button until the FAN indicator light comes on Press the FAN SPEED button to choose the fan speed The temperature cannot be adjusted Do not put the duct to window TIMER operation When the unitis on first press the Timer button the TIMER OFF indicator light illuminates It indi cates the Auto Stop program is initiated When the unitis off first press the Timer button the TIMER ON indic ator light illuminates It indicates the Auto Start program is initiated Press or hold the UP or DOWN button to change the Auto time by 0 5 hour increments up to 10 hours then at 1 hour increments up to 24 hours The control will count down the time remaining until start The selected time will register in 5 second and the system will autom atically revert back to display the previous temperature setting Turning the unit ON or OFF at any time or adjusting the timer setting to 0 0 will cancel the Auto Start Stop timed program When the malfunction E1 E2or E4 occurs the Auto Start Stop timed program will also be cancelled SLEEP operation Press this button the selected temperature will increase cooling or decrease heating by 1 C 2 F 30 minutes The temperature will then increase cooling or decrease heating by another 1 C 2 F after an additional 30 minutes This new temper ature will be maintained for 7 hours before it returns to the originally se
7. more than 2 seconds can initiate the auto swing feature Operating Instructions COOL operation Pressthe MODE button until the COOL indicator light comes on Press the ADJUST buttons or to select your desired room temperature The temperature can be set within a range of 17 C 30 C 62 F 88 F Press the FAN SPEED button to choose the fan speed HEAT operation cooling only models without Press the MODE button until the HEAT indicator light comes on Press the ADJUST buttons or to select your desired room temperature The temperature can be set within a range of 17 C 30 C 62 F 88 F Press the FAN SPEED button to choose the fan speed For some models the fan speed can not be adjusted under HEAT mode DRY operation Press the MODE button until the DRY indicator light comes on Under this mode you cannot select a fan speed or adjust the temperature The fan motor operates at LOW speed Keep windows and doors closed for the best dehumidifying effect Do not put the duct to window AUTO operation When you set the air conditioner in AUTO mode it will automatically select cooling heating cooling only models without or fan only operation depending on what temperature you have selected and the room temperature O The air conditioner will control room temperature automatically round the temperature point set by you Under AUTO mode you can not select the
8. outlet of the unit Allow at least 30cm of space from the wall for efficient air conditioning Window Slider kit Installation Your window slider kit has been designed to fit most standard Vertical and horizontal window applications However it may be necessary for you to improvise modify some aspects of the installation procedures for certain types of window Please refer to Fig 8 amp Fig 9 for minimum and maximum window openings Window slider kit can be fixed with a bolt see Fig 9a Note If the window opening is less than the mentioned minimum length of the window slider kit cut that one with a hole in it short to fit for the window opening Do never cut out the hole in window slider kit bolt bolt Window slider kit indow slider kit Fig 9a Foam seal A adhesive type Fig 10 Window kit Window kit Window stool Fig 11 Window kit n Window stool Window kit Window stool Fig 12 Foam seal Fig 13 INSTALLATION INSTRUCTIONS optional Installation in a double hung sash window 1 Cut the foam seal adhesive type to the proper length and attach it to the window stool Fig 10 2 Attach the window slider kit to the window stool Adjust the length of the window slider kit according to the width of window shorten the adjustable window kit if the width of window is less than 27 inches Open the window sash and place the window slider kit on t
9. the LCD display window To set the Auto off time 1 Press the TIMER OFF button The remote controller shows TIMER OFF the last Auto off setting time and the signal h will be shown on the LCD display area Now it is ready to reset the Auto off time to START the operation 2 Push the TIMER OFF button again to set desired Auto off time Each time you press the button the time increases in 30 minutes increments up to 10 hours then at 1 hour increments up to 24 hours 3 After setting the TIMER OFF there will be a one half second delay before the remote controller transmits the signal to the air conditioner Then after approximately another 2 seconds the signal h will disappear and the set temperature will re appear on the LCD display window 9 IMPORTANT e The effective operation time set by the remote controller for the timer function is limited to the following settings 0 5 1 0 1 5 2 0 2 5 3 0 3 5 4 0 4 5 5 0 5 5 6 0 6 5 7 0 7 5 8 0 8 5 9 0 9 5 10 11 12 13 14 15 16 17 18 19 20 21 22 23 and 24 Example of Timer setting qz quy Buh TIMER ON Start Set 6 hours later TIMER ON Auto on Operation The TIMER ON feature is useful when you want the unit to turn on automatically before say when you return home The air conditioner will automa tically start operating at the set time Example To start the air conditioner in 6 hours 1 Press
10. unit 3 Do not wash the unit directly under a tap or using a hose lt may cause electrical danger 4 If the power cord is damaged it should be repaired by manufacture or its agency 1 Air filter Clean the air filter at least once every two weeks to prevent inferior fan operation because of dust Removal This unit has two filter Grasp the upper filter tab Fig 26 pull the filter out then up Remove the lower filter by loosening the screws taking down the air inlet grille then removing the air filter as shown in Fig 27 amp 28 Cleaning Wash the air filter by immersing it gently in warm water about 40 C 104 F with a neutral detergent Rinse the filter and dry it in a shady place Mounting Insert the upper air filter from upward after cleaning attach the lower air filter to the air inlet grille then install the grille by using the screws Make sure the screws are securely fastened 2 Unit enclosure Use a lint free cloth soaked with neutral detergent to clean the unit enclosure Finished by a dry clean cloth 3 Unit idle for a long time Remove the rubber plug at the back of the unit and attach a hose to drain outlet Place the open end of the hose directly over the drain area in your basement floor See Fig 23 amp 24 Remove the plug from the bottom drain outlet all the water in the bottom tray would drain out See Fig 25 Keep the appliance running on FAN mode for half a day
11. Before you begin thoroughly familiarize yourself with the control panel and remote controller and all its functions then follow the symbol for the functions you desire The unit can be controlled by the unit control panel alone or with the remote controller NOTE This manual does not include Remote Controller Operations see the Remote Controller Instruction packed with the unit for details OPERATION PANEL OF THE AIR CONDITIONER Remote signal receptor The model has no auto swing feature withou t this button e O TIMERON O TIMEROFF Fig 4 MODE select button Selects the appropriate operating mode Each time you press the button a mode is selected in a sequence that goes from AUTO COOL DRY FAN and HEAT cooling only models without The mode indicator light illuminates under the different mode settings Fig 4 TIMER button Used to initiate the AUTO ON start time and AUTO OFF stop time program in conjuction with the A 8 Y buttons POWER button Power switch on off SLEEP button Used to initiate the SLEEP operation FAN button Control the fan speed Press to select the fan speed in four steps LOW MED HI and AUTO The fan speed indicator light illuminates under different fan settings except AUTO speed When select AUTO fan speed all the fan indicator lights turn dark Some models have the signal receptor on the front panel Fig 2 O UP A and DOWN button Used to adju
12. Gets 11m Environment E 60 41 1409F NOTE Temperature setting display Celsius scale C R51I14 BG C E R51116 BG C E Fahrenheit scale F R51113 BG C E R51115 BG C E R51117 BG C E Performance Feature 1 Operating Mode AUTO COOL DRY HEAT Cooling only model without and FAN 2 Timer Setting Function in 24 hours 3 Indoor Setting Temperature Range 11 303 62 F 88 F 4 Full function of LCD Liquid Crystal Display 5 Back light emitting Function buttons SET TEMPERATURE C AUTO FAN COOL HIGH DRY MED HEAT LOW he n Y TEMP A i TEMP UP Button Push this button to increase the indoor temper ature setting in 1 C 2 F increments to 30 C 88 F TEMP DOWN Button Push this button to decrease the indoor temper ature setting in 1 C 2 F increments to 17 C 62 F Each time the button is pressed the operation DH IG MODE Button O DE O O CO aa uem COOL gt DRY 7 HEAT gt FAN Cor o O E aD BR C RN Lud Model R51114 BG C E R51116 BG C E NOTE R51116 BG C E models have no SWING feature NOTE Heat mode is for Cooling amp Heating models only SWING Button on some models Used to stop or start louver movement and set the desired up down airflow direction RESET Button Once the recessed RESET button is pressed all of the current settings will be cancelled an
13. MER ON resetLock TIMER OFF How to use the buttons Auto operation Ensure the unit is plugged in and power is available The OPERATION indicator on the display panel of the indoor unit illuminates 1 Press the MODE button to select Auto 2 Press the TEMP button to set the desired temperature The temperature can be set within a range of 17 C 62 F 30 in 1 C 2F increments 3 Press the ON OFF button to start the air conditioner NOTE 1 In the Auto mode the air conditioner can logically choose the mode of Cooling Fan Heating and Dehumidifying by sensing the difference between the actual ambient room temperature and the set temper ature on the remote controller 2 In the Auto mode you can not switch the fan speed It has already been automatically controlled 3 If the Auto mode is not comfortable for you the desired mode can be selected manually Cooling Heating Fan operation Ensure the unit is plugged in and power is available 1 Press the MODE button to select COOL HEAT cooling amp heating models only or FAN mode 2 Press the TEMP button to set the desired temperature The temperature can be set within a range of 17 C 62F 30 C in 1 C 2 F increments 3 Press the FAN SPEED button to select the fan speed in four steps Auto Low Med or High 4 Press the ON OFF button to start the air conditioner NOTE In the FAN mode the setting temperature is not displayed in the remo
14. d the controller will return to the initial settings ON OFF Button Operation starts when this button is pressed and stops when the button is pressed again FAN SPEED Button Used to select the fan speed in four steps f Auto Low Med High O TIMER ON Button Press this button to activate the Auto on time setting Each press will increase the time setting in 30 minutes increments up to 10 hours then at 1 hour increments up to 24 hours To cancel the Auto on time setting just press the button until the time setting is 0 0 ECONOMY SLEEP Button Select this function during the sleeping time It can maintain the most comfortable temperature and save energy This function is available on COOL HEAT or AUTO mode only Q u Function buttons continued Indicators on LCD DEED SET TEMPERATURE F AUTO FAN COOL HIGH DRY MED HEAT LOW LA AA Y TEMP A CODCOD MODE ONOFF FAN SPEED SWING ECONOMY TIMERON RESETLock TIMER OFF oo LED DISPLAY U NOTE While the unit is running under Energy saving mode it would be cancelled if any other buttons are pressed TIMRT OFF Button Press this button to activate the Auto off time setting Each press will increase the time setting in 30 minutes increments up to 10 hours then at 1 hour increments up to 24 hours To cancel the Auto off time setting just press the button until the time setting is 0 0 LOCK Button Press this rec
15. essed button to lock all current settings and the remote controller will not accept any operation except that ofthe LOCK Use the LOCK mode when you want to prevent settings from being changed accidentally Press the LOCK button again to cancel the LOCK function A lock MODE display Displays the current selected mode Including AUTO COOL DRY HEAT cooling amp heating models only and FAN Transmission Indicator This transmission indicator will light when remote controller transmits signals to the indoor unit Temp Timer display The temperature setting from 17 C 62 F to 30 C 88 F or timer setting 0 24h will be displayed If FAN mode is selected there will be no display ON OFF display This indicator will be displayed when the unit is operating SET TEMPERATURE F Y TEMP A E MODE __ONIOFF FAN SPEED SWING SLEEP TIMER ON oo FOLLOW LED ME DISPLAY Model R51117 BG C E ION REsErtock TIMER OFF remote display is actual temperature at its location The remote control will send this signal to the air conditioner every 3 minutes interval until press the Follow Me button again The Follow Me function is not available under DRY and FAN mode Switch the operation mode or turn off the unit will cancel the follow me function automatically ION Button When push this button the ion generator is energized and will hel
16. h press until it move to a position which would affect the cooling or heating effect of the air conditioner it would automatically change the swing direction fkeep pressing the SWING button more than 2 seconds the auto swing feature is activated The louver swings as shown in Fig 6 INSTALLATION INSTRUCTIONS optional y gt 3 SN by gt or Horizontal window y y Window Slider Kit Minimum 67 5cm 2 22ft Maxmum 123cm 4 04ft Horizontal window Window Slider Kit or Minimum 67 5cm 2 22ft Maxmum 123cm 4 04ft Horizontal window Window Slider Kit or gt Horizonta window gt o Window Slider Kit Fig 8 Minimum 67 5cm 2 22ft Fig 9 Maxmum 123cm 4 04ft Minimum 67 5cm 2 22ft Maxmum 123cm 4 04ft INSTALLATION INSTRUCTIONS Location The air conditioner should be placed on a firm foundation to minimize noise and virbration For safe and secure positioning place the unit on a smooth level floor strong enough to support the unit The unit has casters to aid placement but it should only be rolled on smooth flat surfaces Use caution when rolling on carpet surfaces Do not attempt to roll the unit over objects e The unit must be placed within reach of a properly rated grounded socket Never place any obstacles around the air inlet or
17. he air conditioner It is normal 6 Power shut off at Heating mode The automatic over heat protection function When the temperature at the air outlet exceed 70 C 158 F the device will stop Switch on again after the unit has cool down AIR CONDITIONER REMOTE CONTROL kogan CONTENTS Handling the remote controller eene Remote controller Specifications eeeeeessusse Function buttons o ina Indicators on LOD iier How to use the buttons usunssrnnennnnnnnnnnonnannnnnnnnnnnnnnnnnnnnnnnnnennnnn AAA A Cooling Heating Fan operation eeeennnee Dehumidifying operation uuussssssnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn Swing OperatlOn reine eo A A Timer OPC RAT ONS e a nata iio ECONOMY operation cccccceceeseeeeeeeeeeeeeeeeeeeeeeeeeeeseesneaneeseeeees Handling the remote controller Location of the remote controller e Use the remote controller within a distance of 8 meters from the appliance pointing it towards the receiver Reception is confirmed by a beep ny ACAUTIONS e The air conditioner will not operate if curtains doors or other materials block the signals from the remote controller to the indoor unit Prevent any liquid from falling into the remote controller Do not expose the re
18. he window stool Fig 11 3 Cut the foam seal adhesive type to the proper length and attach it on the top of the window Shown as in Fig 12 4 Close the window sash securely against the window 5 Cut the foam seal to an appropriate length and seal the open gap between the top window sash and outer window sash Shown as in Fig 13 e INSTALLATION INSTRUCTIONS optional Installation in a sliding sash Foam seal A adhesive type window 1 Cut the foam seal adhesive type to the proper iac length and attach it to the window frame Fig 14 ig 2 Attach the window slider kit to the window stool Adjust the length of the window slider kit according Window to the width of window shorten the adjustable window panel I kit if the width of window is less than 27 inches Open the window sash and place the window slider 0 26 5 48 kit on the window stool See Fig 15 3 Cut the foam seal adhesive type to the proper or length and attach it on the top of the window Shown as in Fig 16 Window panel E ut 26 5 48 4 Close the sliding sash securely against the window O E 5 Cut the foam seal to an appropriate length and seal the open gap between the top window sash and outer window sash Shown as in Fig 17 Fig 15 or Fig 16 Foam sea me Fig 17 INSTALLATION INSTRUCTIONS Exhaust hose installation The exhaust hose and adaptor must be installed or removed in accordance
19. in a warm room to dry the appliance inside and prevent mold forming Stop the appliance and unplug it wrapped the cord and bundle it with the tape Fig 29 Remove the batteries from the remote controller Clean the air filter and reinstall it Unscrew the exhaust hose to the right or left and pull out for uninstallation Fig 30 keep it safety or place behind the air intake grille and cover the window wall hole with the adaptor cap e TROUBLESHOOTING TIPS TROUBLE SHOOTING TROUBLES POSSIBLE CAUSES SUGGEST REMEDIES 1 Unit does not Start when Pressing on off Button P1 appears in the display window Room temperature is lower than the set temperature Cooling mode Drain the water in the bottom tray Reset the temperature 2 Not cool enough The windows or doors in the room are not closed Make sure all the windows and doors are closed There are heat sources inside the room Remove the heat sources if possible Exhaust air duct is not connected or blocked Connect the duct and make sure it can function properly Temperature setting is too high Decrease the set temperature Air filter is blocked by dust Clean the air filter 4 Noisy or vibration The ground is not level or not flat enough Place the unit on a flat level ground if possible 5 Gurgling sound The sound comes from the flowing of the refrigerant inside t
20. lected temperature This ends the Sleep mode and the unit will continue to operate as originally programmed NOTE This feature is unavailabe under FAN or DRY mode Adjust manually Fig 5 Swing automatically Fig 6 OPERATING INSTRUCTIONS Other features Power Outage In the case of a power outage or interruption the unit will auto matically re start in the settings ast used after the poweris restored Wait 3 minutes before resuming operation After the unit has stopped it can not be restarted operation in the first 3 minutes This is to protect the unit Operation will automatically start after 3 minutes Air flow direction adjustment The louver can be adjusted manually or automatically according to the different models Adjustthe air flow direction manually Fig 5 The louver can be set to the desired position manually The max setting angle is about 60 please do not force to set any larger Do not place any heavy objects or other loads on the louver doing so will cause damage to the unit Ensure the louver is fully opened under heating operation Keep the louver fully opened during operation e Adjust the air flow direction automatically Fig 6 When operation is ON the louver opens fully Use the SWING button on the remote controller can stop the louver at the desired angle The louver move up to an angle of 6 for eac
21. ller and Battery 1set HEAT heat pump type 5 C 41 F 30 C 88 F For remote control models only HEAT electrical heat type s30 C 88 F Drain hose 1pc Note Performance may be reduced outside ofthese operating temperatures Suggested tools for window kit installation NOTE Optional parts some models without Check all the accessories are included in the package and please refer to the installation instructions for their usage NOTE All the illustrations in this manual are for explanation purpose only Your air conditioner may be slightly different The actual shape shall prevail 1 Screwdriver medium size Phillips 2 Tape measure or ruler 3 Knife or scissors 4 Saw In the event that the window kit needs to be cut down in size because the window is too narrow for direct installation e IDENTIFICATION OF PARTS NAMES OF PARTS Front Model B Fig 2 Rear Fig 3 oco oo 89 886 eceooo0 Operation Panel Horizontal Louver Blade swing automatically Caster Carrying Handle both sides Operation Panel Horizontal Louver Blade manually Remote signal receptor Caster Carrying Handle both sides Upper Air Filter Behind the grille Air Outlet Power cord outlet Air intake Drain Outlet Exhaust hose Air intake grille Bottom tray drain outlet AIR CONDITIONER FEATURES ELECTRONIC CONTROL OPERATING INSTRUCTIONS
22. mote controller to direct sunlight or heat If the infrared signal receiver on the indoor unit is exposed to direct sunlight the air conditioner may not function properly Use curtains to e prevent the sunlight from falling on the receiver If other electrical appliances react to the remote controller either move these appliances or consult your local dealer M Replacing batteries The remote controller is powed by two dry batteries RO3 LRO3X2 housed in the rear part and protected by a cover 1 Remove the cover by pressing and sliding off 2 Remove the old batteries and insert the new batteries placing the and ends correctly 3 Reattach the cover by sliding it back into position NOTE When the batteries are removed the remote controller erases all programming After inserting new batteries the remote controller must be reprogrammed 9 ACAUTIONS e Do not mix old and new batteries or batteries of a different type e Do not leave the batteries in the remote controller if it is not going to be used for 2 or 3 months Dispose of the old batteries in the special containers to be found in the sales outlets Remote Controller Specifications R51113 BG C E R51114 BG C E Model R51115 BG C E R51116 BG C E R51I17 BG C E Rated Voltage 3 0V Dry batteries RO3 LRO3j2 Lowest Voltage of 20V CPU Emitting Signal Signal Receiving 8m when using 3 0 voltage Range it
23. ning function will be activated the set temperature will increase cooling or decrease heating by 1 C 2 F over the Next 30 minutes and by another 1 C 2 F after an additional 30 minutes This new temperature will be maintained for 7 hours before it returns to the originally selected temperature NOTE On some models the set temperature will increase cooling or decrease heating by 1 C 2 F per hour for 2 hours This new temperature will be maintained for 5 hours then the unit is off NOTE The ECONOMY SLEEP function is only available under Cooling Heating and AUTO operation e i
24. of at least free of charge to the user B When buying a new product the retailer will take back the old product at least free of charge C The manufacture will take back the old appliance for disposal at least free of charge to the user D As old products contain valuable resources they can be sold to scrap metal dealers Wild disposal of waste in forests and landscapes endangers your health when hazardous substances leak into the ground water and find their way into the food chain SAFETY PRECAUTIONS Safety rules To prevent injury to the user or other people and property damage the following instructions must be followed Incorrect operation due to ignoring of instructions may cause harm or damage EB Always do this SNA Never do this IDENTIFICATION OF PARTS For your safety Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Avoid fire hazard or electric shock Do not use an extension cord or an adaptor plug Do not remove any prong from the power cord Do not operate your air conditioner in a wet room Your air conditioner should be used in such a way splashed water etc Do not place or store your air conditioner where it can fall or be pulled into water or any other liquid Unplug immediately Always transport your air conditioner in a vertical position and stand on a stable level surface during use
25. p to remove pollen and impurities from the air Model R51113 BG C E symbol will appear on the remote controller display WA eos EW MODE display FAN mode R51115 BG C E when the lock function is activated a F1 F1 gt LED Display Button i NOTE RS1I15 BG C E s Press this Button to clear the display on the Ll LI Lug FAN SPEED display models hav e no SWING ind it it ade liohtihedisal y SIMER ONOFF A Displays the selected fan speed AUTO HIGH MED REDE IS pissing dv Ml Suena and LOW Nothing displays when the fan speed is feature FOLLOW ME Button selected in AUTO speed When AUTO or DRY Mode O Press this button to initiate FOLLOW ME function is selected there will be no signals displayed When the Follow Me function is activated the TIMER display This display area shows the settings of the TIMER That is if only the Auto on time function is set it will display TIMER ON If only the Auto off time function is set it will display TIMER OFF If both functions are set it will display TIMER ON OFF which indicates you have chosen both the Auto on time and Auto off time LOCK Indicator LOCK display is displayed when pushing the LOCK button Push the LOCK button to clear display O TO AUTO lt q rm FAN Suis HEAT E Li LOW ge 9 SET TEMPERATURE C Y TEMP A SWING ECONOMY TIMER ON ReserLock TIMER OFF ZEND SET TEMPERATURE C Lem m y 9 SWING ECONOMY TI
26. rs after setting and start it again 10 hours after setting 1 Press the TIMER OFF button 2 Press the TIMER OFF button again to display 2 0h on the TIMER OFF display 3 Press the TIMER ON button 4 Press the TIMER ON button again to display 10h on the TIMER ON display 5 Wait for the remote control to display the setting temperature IL ri HE t TIMER ON OFF Start E A Off j Stop Set FON SET TEMPERATURE C AUTO lt FAN zn B HEAT L Li LOW Y TEMP A COCO MODE __ONIOFF FAN SPEED SWING ECONOMY TIMERON 2 hours later 5 hours later after setting after setting RESETLOcK TIMER OFF O TIMER ON j TIMER OFF Off Start Stop operation This feature is useful when you want to start the air conditioner before you wake up and stop it after you leave the house Example To start the air conditioner 2 hours after setting and stop it 5 hours after setting 1 Press the TIMER ON button 2 Press the TIMER ON button again to display 2 0h on the TIMER ON display 3 Press the TIMER OFF button 4 Press the TIMER OFF button again to display 5 0h on the TIMER OFF display 5 Wait for the remote control to display the setting temperature e The timer setting TIMER ON or TIMER OFF that in sequence occurs directly after the set time will be activated first ECONOMY SLEEP operation When you press the ECONOMY button the economic run
27. st increasing decreasing temperature settings 1 C 2 F increments in a range of 17 C 62 F to 30 C 88 F or the TIMER setting in a range of 0 24hrs NOTE The control is capable of displaying temperature in degrees Fahrenheit or degrees Celsius To convert from one to the other press and hold the Up and Down buttons at the same time for 3 seconds LED Display Shows the set temperature in C or F and the Auto timer settings While on DRY and FAN modes it shows the room temperature Error codes E1 Room temperature sensor error Unplug the unit and plug it back in If error repeats call for service E2 Evaporator temperature sensor error Unplug the unit and plug it back in If error repeats call for service E4 Display panel communication error Unplug the unit and plug it back in If error repeats call for service P1 Bottom tray is full Connect the drain hose and drain the collected water away If error repeats call for service OPERATING INSTRUCTIONS ION button optional Press the ION button the ion generator is ener gized and will help to remove pollen and impur ities from the air and trap them in the filter Press it again to stop the function G SWING button Applicable to the models with auto swing feature only When the operation is ON press the SWING button can stop the louver at the desired angle The louver swing up to an angle of 6 for each press Keep pressing the button
28. te controller and you are not able to control the room temperature either In this case only step 1 3 and 4 may be performed Q ZEND SET TEMPERATURE C E FAN emis HEAT a LOW AUTO COOL DRY ces QUE a TO E NN s Nooo o V AUTO rm FAN COOL 7 r1 HIGH DRY lt E 1 MED HEAT a LOW Y TEMP A MODE __ONIOFF FAN SPEED SWING Economy TIMER ON RESETLock TIMER OFF oo LED DISPLAY NA SET TEMPERATURE C L ae Q7 Y TEMP A CODCOD MODE __ON OFF FAN SPEED SWING ECONOMY TIMERON RESET LOCK TIMER OFF oo LED DISPLAY lu ONE ER Dehumidifying operation Ensure the unit is plugged in and power is available The OPERATION indicator on the display panel of the indoor unit illuminates 1 Press the MODE button to select DRY mode 2 Press the TEMP button to set the desired temperature The temperature can be set within a range of 17 C 62 F 30 C in 1 C 2 F increments 3 Press the ON OFF button to start the air conditioner NOTE In the Dehumidifying mode you can not switch the fan speed It has already been automatically controlled Swing operation on some models Use the SWING button to adjust the Up Down airflow direction 1 When press the button once and quickly the air flow direction setting feature of the louver is activated The moving angle of the louver is 6 for each press Keep pressing the button to
29. the TIMER ON button the last setting of starting operation time and the signal h will show on the display area 2 Press the TIMER ON button to display 6 0h on the TIMER ON display of the remote controller 3 Wait for about 3 seconds and the digital display area will show the temperature again Now this function is activated i uh TIMER OFF 1 Start Set 10 hours later Lo I Li h TIMER ON OFF Stop On Saran Set 2 hours later after setting 10 hours later after setting TIMER OFF Auto off Operation The TIMER OFF feature is useful when you want the unit to turn off automatically after you go to bed The air conditioner will stop automatically at the set time Example To stop the air conditioner in 10 hours 1 Press the TIMER OFF button the last setting of stopping operation time and the signal h will show on the display area 2 Press the TIMER OFF button to display 10h on the TIMER OFF display of the remote controller 3 Wait for about 3 seconds and the digital display area will show the temperature again Now this function is activated COMBINED TIMER Setting both ON and OFF timers simultaneously TIMER OFF j TIMER ON On j Stop j Start operation This feature is useful when you want to stop the air conditioner after you go to bed and start it again in the morning when you wake up or when you return home Example To stop the air conditioner 2 hou
30. with the usage mode Exhaust hose COOL HEAT heat pump type or AUTO Install mode FAN DEHUMIDIIFY or HEAT electrical heat type Remove Fig 18 mode For the first time to use the machine take the exhaust hose cue out as shown in Fig 18 1 Install the adaptor B and adaptor onto the exhaust hose as Adaptor 1 ra mouth shown in Fig 19a or Fig 19b Refer to the previous pages for window kit installation Flat mouth 2 Place the Exhaust hose over against the air outlet opening Mm i fc TT H hook and flat the other end See Fig 20 for quick installation ee M 2 Note Fig 19a Fig 19b Extend the both ends of the exhaust hose to a length of 30 50mm before install the adaptor B and apaptor onto the exhaust hose The exhaust hose can be installed into the wall Not applicable to the units without adaptor A expansion plugs and wooden screws of Accessories 1 Prepare a hole in the wall Install the wall Exhaust adaptor A onto the wall outside by using 4 expansion plugs and wooden screws be sure to fix thoroughly See Fig 21 2 Attach the Exhaust hose installed adaptor B round mouth to wall Exhaust adaptor A Note Cover the hole using the adaptor cap when not in use eThe exhaust hose can be compressed or extended moderately according to the installation requirement butitis desirable to keep the hose length to a minimum IMPORTANT DO NOT OVER BEND THE EXHAUST HOSE SEE Fig 22

Download Pdf Manuals

image

Related Search

Related Contents

高温はんだ付け装置(チタン製ハンダ槽)  Furuno FAR-2167DS-D Marine RADAR User Manual  Sony KDL-46V5500E 46" Full HD Black LCD TV  Handbook of Operating Instructions for Radio  Gear Head MP1600RU mice  GHC 10 - Garmin  Quick Reference Guide  dreamGEAR 17 In 1 Bundle Pak for DS Lite    Betriebsanleitung VEGAMET 624  

Copyright © All rights reserved.
Failed to retrieve file