Home
INSTALLATION and OPERATING INSTRUCTIONS NOVARIS
Contents
1. Tel 613 6229 7233 FAX 613 6229 9245 Date 17 03 02 Page 4 of 10 Email sales novaris com au URL www novaris com au Installation Manual Three Phase Medium Current Novaris 2 Specifications No phases Rated operating voltage Rated VA Maximum operating voltage Insertion voltage drop Efficiency Protection modes Surge withstand 8 20us impulse Frequency response Internal protection Alarms Dimensions backplane Dimensions enclosure Enclosure Environmental rating Location Novaris Pty Ltd Tel 613 6229 7233 Email sales novaris com au n 72 Browns Road Kingston TAS 7050 AUSTRALIA FAX 613 6229 9245 Date 17 03 02 Page 5 of 10 URL www novaris com au 3 240V AC x 32A 21KVA 40A 28 8KVA 63A 45 3KVA 125 90KVA 275V ACq w lt 2V per phase at full load 99 Transverse and common mode SF3xx 16KA per phase SF3xx 40 AOKA per phase SF3xx 80 80KA per phase SF3xx 120 120KA per phase SF3xx 160 160KA per phase SF3xx 200 200KA per phase 3dB point 800Hz Each surge diverter individually protected with series fuse and thermal overload indication LED display of surge diverter function for 16KA and 40KA versions Digital display of active for 80KA 200KA units using MULTIMOV External alarm via voltage N O contact Other options available 450H x 350W x 120D 16kA 40kA 450H x 350W x 200D 40kA 200kA 500H x 400W x 120D 16kA 40kA 500H x
2. MULTIMOV surge diverter segments so that a segment failure will not effect filter performance Novaris Pty Ltd 72 Browns Road Kingston TAS 7050 AUSTRALIA Section SK07 Revision 1 Tel 613 6229 7233 FAX 613 6229 9245 Date 17 03 02 Page 8 of 10 Email sales novaris com au URL www novaris com au Installation Manual Three Phase Medium Current Novaris S Warranty This is limited to 5 years and is given by Novaris Technologies Pty Ltd Novaris to the original purchaser of products made by Novaris the products The warranty certificate must be completed by the distributor and the purchaser in order to claim under this warranty 1 What Novaris will do If the product fails under normal use and service because of a manufacturing defect in materials or workmanship within 5 years from the date of purchase Novaris will at its option either repair or replace the product with an equivalent product The repaired or replacement product will be warranted under the terms of this warranty for the remainder of the warranty period for the product originally supplied 2 How to obtain warranty service To obtain warranty service you must return the product to Novaris The product must be accompanied by the warranty certificate duly completed along with your sales receipt or invoice Freight and insurance is your responsibility 3 What is not covered This warranty does not cover any failure of equipment not supplied by Novaris or
3. be affected The purpose of the filter is to remove surges and other transient overvoltage disturbances which may be caused by induction or direct injection It is therefore vital to segregate input and output cabling Do not run these cables in a common duct Treat the input cabling as dirty The optimum cabling configuration is to run input or line side cabling in the bottom left hand side of the cabinet and output or load cabling out the bottom right hand side Correct earthing is essential Run an earth conductor of size specified in AS3000 or the relevant wring rules to the nearest earth bar or station earth bus Avoid sharp bends and keep the earth conductor as short as possible The best earth connection is made with 25 x 3mm copper strap Otherwise use at least 16mm conductor Novaris Pty Ltd 72 Browns Road Kingston TAS 7050 AUSTRALIA Section SK07 Revision 1 Tel 613 6229 7233 FAX 613 6229 9245 Date 17 03 02 Page 6of10 Email sales novaris com au URL www novaris com au Installation Manual Three Phase Medium Current Novaris Connect the external alarm if necessary A voltage free N O contact is provided Rewiring the alarm connections to the line and load side surge diverters may modify this Maximum conductor size is 2 5mm These contact descriptions relate to the power on condition Under normal operating conditions the relay is energised After installation the filter may be tested for continuity and insulat
4. 400W x 200D 40kA 200kA Pressed steel powdercoated IP55 Main switchboard or distribution board in all TN and TT distribution systems Section SK07 Revision 1 Installation Manual Three Phase Medium Current Novaris 3 Installation One of the most important factors determining the performance of Novaris Technologies filters is the manner in which they are installed Main Switch LINE LOAD E4 L1 74 L1 A L1 ie L2 L2 L2 eem l Supply Authority Circuit Breaker Service Fuses Optional Neutral Power Line Surge Filter Earth Electrode It is mandatory that Novaris Technologies filters be installed by a licensed electrician in accordance with Australian Standard AS3000 or the relevant country wiring rules To meet AS3000 the filter must be protected by a circuit breaker or fuses of rating equal to the current rating of the filter 125A filters may be fitted with line fuses If these are not included the filter must be preceded by external fuses or a circuit breaker If some latitude is allowed in the positioning of this filter choose a location which affords a short direct run to a substantial earthing point either a station earth bar or switchboard earth bus The filter should be installed before any earth leakage protection devices although earth leakage is negligible and once power is applied ELCB operation will not
5. INSTALLATION and OPERATING INSTRUCTIONS NOVARIS TECHNOLOGIES SURGE FILTERS Medium Current Three Phase Installation Manual Three Phase Medium Current Novaris Thank you for choosing a Novaris Technologies surge filter for your protection requirements This manual explains the operation and features of your filter as well as installation information In addition troubleshooting and maintenance guides are provided For this filter to function correctly it must be installed as described Please instruct your installation personnel to read this manual before proceeding with installation WARNING THIS UNIT IS DESIGNED FOR CONNECTION TO THE AC MAINS DANGEROUS VOLTAGES EXIST ON COMPONENTS INSIDE THE CASE THIS PRODUCT MUST BE INSTALLED BY A LICENCED ELECTRICAL CONTRACTOR IN ACCORDANCE WITH AUSTRALIAN STANDARD AS3000 OR THE RELEVANT COUNTRY WIRING RULES Novaris Pty Ltd 72 Browns Road Kingston TAS 7050 AUSTRALIA Section SK07 Revision 1 Tel 613 6229 7233 FAX 613 6229 9245 Date 17 03 02 Page 2 of 10 Email sales novaris com au URL www novaris com au CONTENTS Operation Specifications Installation Maintenance Warranty Ue UA rel Novaris Pty Ltd 72 Browns Road Kingston TAS 7050 AUSTRALIA Section SK07 Revision 1 Tel 613 6229 7233 FAX 613 6229 9245 Date 17 03 02 Page 3 of 10 Email sales novaris com au URL www novaris com au Installation Manual Three Phase Medium Current Novaris 1 Operatio
6. any consumables attached to or forming part of the product nor does it cover any failure of or damage to the product due to a it being connected to equipment or accessories not authorised by Novaris b improper handling misuse neglect accident improper installation or non compliance with the directions for use c any alteration or modification which in the opinion of Novaris will affect the ability to service the product or d repair by anyone other than an authorised Novaris service agent No guarantee is given concerning the operation of surge or transient protection products since atmospheric lightning discharges are an unpredictable process subject to the laws of nature and independent of human control The products do not provide total protection Component parts of some products may be sacrificial when exposed to the effects of lightning and also voltage surges and transients Novaris does not guarantee repair or replacement services will be available after expiration of the 5 year warranty period Novaris Pty Ltd 72 Browns Road Kingston TAS 7050 AUSTRALIA Section SK07 Revision 1 Tel 613 6229 7233 FAX 613 6229 9245 Date 17 03 02 Page 9 of 10 Email sales novaris com au URL www novaris com au Installation Manual Three Phase Medium Current Novaris 4 Rights under the Trade Practices Act It is acknowledged by Novaris that under applicable State and Commonwealth Law certain conditions may be implied and ri
7. e induced common mode voltages The second stage of the filter consists of the inductors and capacitors The LC section low pass filter elements further attenuate surge voltages already clamped by the MOV stages In addition the filter stages attenuate noise and power system harmonics Filter cut off frequency is around 800Hz The filter stage is designed to attenuate both transverse and common mode noise Metal oxide varistors are voltage dependent electrical resistors with symmetrical V I characteristics Their resistance value decreases with increasing voltage thus short circuiting a further rise in overvoltage The metal oxide varistors in Novaris Technologies filters are conservatively rated to handle a large number of surge events However due to the unpredictable nature of transients a varistor may occasionally be overloaded To sense the integrity of each varistor a fuse is connected in series with each MOV Should an overload occur the varistor leakage current will increase causing the fuse to blow To sense this condition the terminal voltage of each varistor is monitored A Digital Percentage active or LED relevant to MOV condition is normally ON and an alarm component condition is signalled to the alarm circuitry External alarm provision is available via a voltage free changeover contact accessible via terminals on the filter backplane Novaris Pty Ltd 72 Browns Road Kingston TAS 7050 AUSTRALIA Section SK07 Revision 1
8. ghts and remedies conferred on the purchaser in relation to the product which cannot be excluded restricted or modified by agreement non excludable rights Novaris disclaims all express or implied conditions and warranties in relation to the product other than the express terms of this warranty and any excludable rights Novaris responsibility to the Purchaser is where permitted limited to the undertakings stated in section 1 of this warranty and subject to the above in no event is Novaris liable where before or after discharge of the contract for supply of the product or otherwise for any loss or damage suffered by the Purchaser as the user caused or contributed to by negligence of Novaris its servants or agents nor is Novaris liable for special incidental indirect or consequential loss or damage suffered by the Purchaser including but not limited to economic loss loss of profit or revenue or reputation or costs arising from the loss of use of the product consumables include indicator lamps and illumination sources items made wholly or partly of glass or ceramic material electrical elements transformer windings electric motors reconditioned parts and batteries Novaris Pty Ltd 72 Browns Road Kingston TAS 7050 AUSTRALIA Section SK07 Revision 1 Tel 613 6229 7233 FAX 613 6229 9245 Date 17 03 02 Page 10 of 10 Email sales novaris com au URL www novaris com au
9. ion with a hand held multimeter A megger test will indicate excessive leakage as it will cause the surge suppression components to operate Novaris Pty Ltd 72 Browns Road Kingston TAS 7050 AUSTRALIA Section SK07 Revision 1 Tel 613 6229 7233 FAX 613 6229 9245 Date 17 03 02 Page 7 of 10 Email sales novaris com au URL www novaris com au Installation Manual Three Phase Medium Current Novaris 4 Maintenance Novaris Technologies surge filters are virtually maintenance free Should any abnormality arise the filter will initiate an alarm condition which will enable the external alarm Inspection of the internal alarms will reveal the nature of the fault Note that a power failure will be interpreted as an alarm condition The surge diverting components are all enclosed in metal cases and may be replaced individually These devices are either DIN rail mounted and may be clipped in and out Alternatively MULTIMOV surge diverters may be panel mounted These are simply held in place with four screws DANGEROUS VOLTAGES EXIST INSIDE THE CABINET THIS WORK SHOULD ONLY BE CARRIED OUT BY QUALIFIED PERSONNEL In all cases of suspected faults contact your distributor or Novaris Technologies Pty Ltd for advice A filter exhibiting an alarm condition does not necessarily have to be taken out of service In most cases some form of protection will still be provided 80kA 120kA 160kA and 200kA versions feature redundant line side
10. n Novaris Technologies power line surge filters are designed for the protection of sensitive equipment from the damaging effects of lightning surges power transients and RF interference Novaris Technologies hardwire filters comprise MOV surge protection plus LC low pass filters for both single and three phase applications The prime surge diverting elements are metal oxide varistors of a rating chosen to suit the application This is primarily based upon current rating of the filter but high surge rating options are available for high exposure sites Three stages of protection include metal oxide varistors inductors and capacitors forming a low pass filter and a final stage of metal oxide varistors The first stage of protection consists of the metal oxide varistors MOVs are connected between each phase and neutral to absorb transverse mode surges usually generated by load switching and other power system disturbances These MOVs in conjunction with the gas arrestor between neutral and ground absorb common mode surges most often caused by lightning induced disturbances or power system earth faults Novaris Technologies power filters are designed for general installation at any point in a LV distribution system When installed near a main switchboard close to the building MEN point the neutral earth components serve no function but are necessary when the filter is installed at distribution boards some distance from the MEN point to remove possibl
Download Pdf Manuals
Related Search
Related Contents
Samsung SGH-X200 Εγχειρίδιο χρήσης Bedienungsanleitung - Printmark Operating Instructions Operating Instructions YAWL Engine User Manual Systèmes de stéréo- fluorescence ラック形非常用放送設備 WL-8500 Lofrans' : catalogue Marlin AS R User Manual ONE owners manual.indb Copyright © All rights reserved.
Failed to retrieve file