Home
OPERATING INSTRUCTIONS - SS3D AUTOMATIC CONTROLLER
Contents
1. Supreme Head Office 9 Lucknow Crescent _ Heati ng Thomastown VIC 3074 Phone 03 9460 4200 Specialists in heating for homes amp pools Fax 03 9460 4900 Distributors in NSW SA and WA www supremeheating com au OPERATING INSTRUCTIONS SS3D AUTOMATIC CONTROLLER The SS3D series of automatic controllers are microprocessor controlled They are used to control the heating of your pool spa from your solar collector INSTALLATION Your automatic controller should be mounted on a wall close to a power outlet and your solar pump Where possible it should be located to minimise exposure to weather Plug your solar pump into the point provided on the underside of the automatic controller Plug the automatic controller directly into a power outlet Turn the power outlet on so as power is supplied to the automatic controller Press the ON button for a few seconds this button has a built in time delay system Once the unit is on a green light next to the ON button should be lit Ensure the automatic controller is set to the AUTO mode This is evident by the green light next to the AUTO MANUAL button being lit RWD O1 HOW DOES IT WORK Your automatic controller has two temperature sensors One on the roof sensing the temperature of the solar collector the other in your plumbing system sensing your pool water temperature When the temperature of the collector is 7 C greater than that of the pool water
2. season is normally from September through to April May depending on where you live and local weather conditions During this time you shouldn t have to do anything except set your pre set maximum temperature The automatic controller will do the rest for you 2 At the end of the solar season simply turn the system off by pressing the SENSORS OFF button It is important to leave power supplied to the unit Whilst the unit is turned off it will operate the pump for ten minutes each day This stops any stagnation occurring in the system and also keeps the pump in good order This is called winter mode 3 The manual operating mode will run your solar pump regardless of weather conditions It is for the use of service personnel only If you have any questions regarding the operation of your automatic controller don t hesitate to call the manufacturer Supreme Heating Supreme Heating Specialists in heating for homes amp pools
3. the automatic controller will turn your solar pump on This will push water through the solar collector in turn heating your pool The automatic controller will turn the system off for one of two reasons 1 The temperature of the roof sensor drops to within 2 C of the pool water sensor Therefore no significant heat gain can be achieved 2 The pool water has reached its pre set maximum temperature SETTING THE PRE SET MAXIMUM TEMPERATURE The SS3D series of automatic controllers allows you to set a maximum desired pool water temperature 1 Press the SELECT button once This will change the display from the current pool temperature to your pre set maximum temperature 2 Use the UP and DOWN buttons to adjust your pre set maximum temperature The display will return to the pool temperature after a few seconds NOTE Pressing the SELECT button twice will change the display to current solar collector temperature _ Solar Pool Heating Pool Blankets Hydronic Heating Solar Hot Water g O creen Z SPASA MEMBER n mart SET TEMPERATURE AUTO SAMPLING If your pool has reached its PRE SET temperature it will activate the automatic sampling mode Because the POOL sensor is located in the pipework around the solar pump and not in the actual pool itself it can heat up quicker and give a false reading The purpose of this mode is to avoid inaccurate pool temperature readings and create more accurate running times Samplin
4. g will occur every 2 hours and the SS3D will turn on the pump for 5 minutes whenever the ROOF temperature is above the SET temperature If the ROOF temperature is below the SET temperature the unit will not sample avoiding night operation COOLING TROPICAL MODE This function can be used in Tropical climates where the pool temperature is too hot Of a night when the ROOF temperature is 7 C or more below the POOL temperature it will turn on the pump and circulate water and cool it to the SET temperature if possible It will turn off if the SET temperature is reached or if the ROOF temperature rises to within 2 C of the pool water temperature To Activate Tropical mode Holding the SET button for 5 seconds while displaying the ROOF temperature will allow cooling mode to be activated Up and down arrows keys are used to change this setting and the SET key to exit Or wait 60 seconds The possible settings are H for heating only HC for heating and cooling Tropical SENSOR DIAGNOSTICS The following errors are now displayed along with flashing lights to indicate a faulty sensor or cable Flashing OC Open circuit possible break in cable Flashing SC Short circuit possible damaged wires making contact Note the relevant flashing sensor needs to be selected for the above messages to be seen WHAT ELSE DO I NEED TO KNOW 1 It is recommended that you use your solar system during the solar season only The solar
Download Pdf Manuals
Related Search
Related Contents
imer_me_2013_it EnjoyTone Robust S09 Manual de usuario Español Trust 520W PSU Big Fan Les observateurs d`états Demande de contrat de raccordement Copyright © All rights reserved.
Failed to retrieve file