Home
Installation Manual PS(+)
Contents
1. Drives from Becker Antriebe are to be mounted and operated solely with mechanical accessory components shown in the current Becker product catalogue 1 Establish the room required at the side for mounting M of the head piece thrust bracket and motor bracket in order to calculate the required length of roller tube The internal dimension of the roller shutter box or sunshade system X minus the overall length of wall bracket head piece M and thrust bracket T gives the length L of the roller tube L X T M Fig 2 3 Measure the distance from the wall bracket and connecting head since this can vary according to the combination of motor and bracket R8 17C PS to R20 17C PS 2 Then fix wall and thrust bracket Please observe the following when assembling the drive e Assembly of the drive adapter with locking device for the R8 17C PS to R20 17C PS drives You can see how to insert the locking device from its shape When insert ing the locking device ensure that the catch locks into place You will hear a click Check that the locking device is in position properly by pulling on the drive adapter Fig 3 e Assembly of the drive adapter with screw connection for the Location lug Le ZR Drive adapter with safety catch Drive adapter R30 17C PS to L120 11 C PS drives Here the drive is fixed with an M6x12 screw It is secured with a plain wash R30 17C PS to L120 11C PS er for M6
2. adapter 58 63 120 mm 120 flat headed sheet metal H Fom diecast drive adapter screw ST 9 5 x 10 DIN 7982 E E 8 5mm E as Tee eee flat headed screws M8 x 58 aluminium drive 120 16 DIN 7991 adapter 18mm Attention F When drilling into the roller tube never drill near the tubular A B drive The tubular drive must not be hit into the tube or dropped into gt H A the roller tube The drive manufacturer also recommends screwing the thrust bearing to the roller tube 5 Hang the tube in the bracket and secure the motorhead piece in the drive bracket 8 6 Hang the mounted unit consisting of tube tubular drive and thrust bracket in the bracket l Cabling Abb 9 d Positioning the end limits There are 3 options for setting the end limits a Point when canopy is extended to point when canopy is retracted without end stop b Point when canopy is extended to end stop IS Note If the tubular drive switches off prematurely because it encounters an obstacle it is possible to release this obstacle by briefly moving the canopy in the opposite direction removing the obstacle and then mov ing the canopy up or down again to set the new end limit programming position switch O reset position E VA rotation arrow Setting the end limits using the switches Attention The switch control set is not designed for permanent use but only for initial operation Connect the flexib
3. and a suitable toothed washer Fig 3 Tapped hole M6x12 screw SS Plain washer SP pi Drive adapter Toothed lock washer pp TENN RS soy EY a cs Assembly and Operating Instructions A 3 Before fitting in the barrel take the measurement from barrel end to the centre of the drive adapter and mark on the barrel Fig 4 e For profile tubes For some drive adapters tolerances of the channel widths in different roller tubes can be balanced by turning the drive adapter in a different channel slot These channel slots come in different sizes and make it an exact fit possible when the drive is installed Fig 5 e For round tubes Release the tube from the motor died in advance so that the cam of the ring can also be inserted into the tube The cam of the ring must not engage with the tube For rings without pull ing cams the roller tube must be connected to the ring by a 4 8 x 10 mm sheet metal screw Fig 6 4 Assemble the tubular drive with the relevant ring A and drive adapter B Insert the tubular drive with the pre assembled ring and drive adapter into the tube as shown Ensure that the ring and drive adapter are correctly positioned in the tube Fig 7 The drive adapter of the tubular drive is connected to the roller tube as follows Size of drive Tubes Torque max Fastening screws mm mm Nm for drivers 4 x 45 ee ania drive 50 flat headed sheet metal j screw ST 6 3 x 10 DIN 7982
4. 1 Drive past this position off automatically be 2 Push the Reset button while being at this fore programming the position desired 1 Final posi tion final position of extention Sample wiring diagram Controlling one several drive s via a single switch button Black Blue Individual switch Subject to technical changes without notice BECKER lo Becker Antriebe GmbH 35 64 Sinn Germany www becker antriebe com 2010 300 3110 09 08 BECKER
5. Itis only possible to delete an individual limit stop if the point when the canopy is extended to the point when the canopy is retracted without end stop has been programmed using the switches Move the switch for the relevant end limit from the programming position to the reset position Press the control command briefly The end limit is deleted b Deleting both end limits Move both switches from the programming position to the reset position Press the control command briefly Both end limits are deleted Setting the end limits using the setting controls Caution The switch control set is not designed for permanent use but only for initial operation Connect the flexible leads of the tubular drive to those of the setting controls product no 4935 200 011 0 according to the colour coding and switch on the power supply ES Note If the tubular drive switches off prematurely because it encounters an obstacle it is possible to release this obstacle by briefly moving the canopy in the opposite direction removing the obstacle and then mov ing the canopy up or down again to set the new end limit Action Reaction a Point when canopy is extended to point when canopy is retracted with out end stop Ss Note When the end limits are set using this method no adjustment is made for the length of the canopy Yin A neon ey Move both switches to the program ming position Move the canopy to the
6. R8 17C PS L120 11C PS fl Assembly and Operating Instructior e Fitters Electricia nto do mm BECKER Assembly and Operating Instructions Table of Contents CONCORDA sc E 2 WILY crews eat pin wae abusa Cica rca oe dida DU CU EO Roda ia Ceni cien Ca SU EU id aU IRES raia audi Ea a dE am 3 salety NTO ais lo serienn RR E RO RM ROMERO RR RR DR ARRERA 3 MEn ed USE errer E E A EE A EE E RN DER RT ERRA 4 Mou u tingand instalation IS RCE ara den biel auun anc msanaemtanan tan ant decumbent ney boceen tan iiveiee 5 Positioning the end MINS asas eu tas aii dus Dogue eine da aa de da ada UA a a q a AREEN T Norman tor ihe EISCUICIAN sessisssseesrinissn narenn en aner niie ann ind A EE O S ENEN 12 Ee AL P E RE pad E AE EAE R EET AA E N P N E E E E E A EEE A E TTE 12 Declaration of Conformity sei id br 12 TG AU MS QE a rare terre E E E A EE E A E E 13 WO CIO Wess epiese E T A EE a ghee EA ENR 14 Sample wiring diagrami asno eeg coantrene ores oecncasresducecedeemedl Oeria E ESEE NEDA E rE a EEE EEN EE redada o 15 General The R8 17C PS L120 11C PS tubular drives are high quality products with numerous performance features e Installation without end stops possible original position to position reached e Automatic recognition of end limits by means of intelligent electronics using end stop systems e No need to adjust end limits changes to canopies curtains are automatically compensated for u
7. ate vicinity of it e Ensure that there is an adequate distance at least 40 cm between moving parts and adjacent objects e Crushing and shearing points must be avoided or protected ES NA O EN Wg E NA BECKER 3 Assembly and Operating Instructions Important safety instructions for the installation and commissioning A Caution Failure to observe these instructions can lead to serious injuries e Please comply with the safety instructions EN 60335 2 97 Please note that these safety instructions cannot be assumed as being complete since this standard does not consider all the possible causes of risk For exam ple the construction of the operated product the effectiveness of the drive in the location of installation or the mounting of the final product in the end user s place of usage cannot be taken into consideration by the drive manufacturer If any questions or concerns regarding the safety instructions contained in the standard arise please contact the manufacturer of the respective part or end product e All operational work including maintenance and cleaning on electrical installations as well as other system parts must always be performed by authorised specialists especially qualified electricians e During operation of electrical or electronic equipment and units certain components are subject to a hazardous electrical voltage Physical injuries or damage to property can result in the event of unqualified interventi
8. e instructions when operating or repairing the system Becker Antriebe shall not accept liability for damages resulting from incorrect usage Mounting and installation instructions 1 Assembly of the Becker connecting cable Fig 1 Ensure the Becker connecting cable is de energised before proceeding In sert the cable into the drive head until the location lug audibly engages behind the self locking clip If necessary use a suitable flat bladed screwdriver to Click insert the cable correctly This is done by inserting the screwdriver into one of a mn the two recesses in the connector CER P Check the locking Disassembly of the Becker connecting cable Fig 1 Caution A Always completely de energise the Becker connecting cable prior to disassembly 1 Carefully insert a suitable flat bladed screwdriver into the recess of the self locking clip until it releases the location lug of the connecting cable 2 Itis now possible to carefully withdraw the Becker connecting cable along with the flat bladed screwdriver Caution A Electrical connections may only be carried out by a qualified electrician Prior to assembly the power supply should be disconnected Please give the enclosed connection informa tion to the electrical fitter carrying out the work The assembler must check in advance that the resistance of the brickwork or sunshade system meets requirements torque of the drive plus weight of the shutter curtain Attention
9. e pei ad pects sarah een L120 11C PS PS PS PS PS PS Nominaltorque Nm 4 50 60 70 so 120 Output speed mim MM fm a pon Min tube diameter mm CS i AN Kitts E RS BECKER E cs Assembly and Operating Instructions What to do if Problem Cause Remedy Tubular drive overruns 1 A short circuit caused by dampness 1 Investigate source dry out the system and the end limit or does reprogramme not reach the setend 2 External devices are connected to the power 2 Check electrical installation remove ex limit leads of the tubular drive ternal device if connected reprogramme system 3 Exchange L1 and N N blue L1 black brown reset the end limits more suspension devices have broken reset the end limits The tubular drive does The tubular drive has been accidentally extend Delete the limit stops reset the outer end limit not retract after setting ed further and switches off automatically and immediately retract the extended limit stop Both end limits have now been set in the tubular drive Tubular drive stops 1 Tubular drive is overloaded 1 Use a more powerful tubular drive arbitrarily impossible 2 Sunshade system keeps jamming friction is 2 Ensure that the sunshade system runs for it to move further in too high smoothly already programmed Tubular drive does not Tubular drive is overheated The tubular drive is operational a
10. gain after a 2 Tubular drive is faulty does not work even 2 Replace the ane carry out RESET with the after standing still for a long period of time programming pushbutton No click may be heard emergency programme tubular drive can be moved up and down using the required setting controls for the purpose of dismoun ting the drive 3 Tubular drive switched off when it en 3 Move the curtain or canopy away from the countered an obstacle the last time it moved obstacle remove the obstacle and set the in the same direction drive to move in the direction required 4 Electrical connection faulty 4 Check the electrical connection Tubular drive only runs Tubular drive is in error mode obstacle reco Reset the end limits or replace the tubular drive for approx 5 Secs gnition malfunctioning When you attempt to The end limits have already been set using the Move both switches to the reset position set the end limits using switches Press the control command briefly the setting controls Move both switches to the programming positi this does not work on simultaneously Reset the end limits using the setting controls When you attempt to The end limits have been reached more than 16 Move both switches to the reset position set the end limits using times Press the control command briefly the switches this does Reset the end limits not work Tubular drives switches Drive has recognized an increase in torque
11. ition has been deleted b Deleting both final positions Move the canopy to a position be tween both final positions 1 Press the reset button 1 2 Additionally press and hold the downward button 2 3 Now release the reset button 1 but keep the downward button 2 pressed 4 Additionally press the reset button 1 again Both final positions have been deleted Reaction The tubular drive makes a clack clack sound to confirm The tubular drive makes a clack clack sound to confirm cs MEN 11 RS soy REY cs Assembly and Operating Instructions Information for the Electrician Becker tubular drives with electronic limit switching can be parallel connected The maximum switching contact loading of the control device timer relay control switch etc must be observed Use external conductor L1 to control the up and down direction Other devices or consumption units lamps relays etc must not be directly connected to the drive connection cables For this purpose the drives and additional units must be decoupled by relay controls When installing the drive an all pole separation capability from the mains with at least 3mm contact opening width per pole must be provided EN 60335 Attention Only use mechanically or electrically locked switching elements with a marked zero position This also applies when drives with electronic and mechanical limit switching are used in the same sy
12. ive an all pole separation capability from the mains with at least 3 mm contact opening width per pole must be provided EN 60335 e If the mains cable is damaged it must be replaced with an identical mains cable pluggable supplied by the drive manufacturer e Never handle the drive via the mains cable e Drives with a HOSVV F connection cable are only to be used inside the building e Drives from Becker Antriebe are to be mounted and operated solely with mechanical accessory components shown in the current Becker product catalogue Intended use Tubular drives of the types R8 17C PS L120 11C PS are designed for operating awnings screens and winter garden shades only Use in coupled systems is only possible if all subsystems are fully synchronised and reach the end limits at the same time Tubular drives of the types R12 17C PS L120 11C PS are specially designed for operating cassette awnings with higher requirements for closing accurate closing of the cassette The mains connection cable is not suitable for supporting the weight of the drive Always support the drive with the housing tube Other applications utilisation and modifications are not permitted in order to protect the safety of the users and others since these actions can impair the system s safety resulting in personal injuries and property damage Becker Antriebe shall not accept liability for damages arising from such actions Always observe the information in thes
13. le leads of the tubular drive to those of the switch control set product no 4901 002 181 0 or of the operator s control according to the colour coding and switch on the power supply a Point when canopy is extended to point when canopy is retracted with out end stop Note When the end limits are set using this method no adjustment is made for the length of the canopy Move both switches to the reset position Press the control command briefly Move the canopy to the required end limit when extended Move the switch with the rotation arrow for extending the canopy from the reset position to the programming position Then move the canopy to the required end limit when retracted Now move the switch with the rotation arrow for retracting the canopy from the reset position to the programming position The end limits are set MEN 7 RS EDH WS a cs Assembly and Operating Instructions b Point when canopy is extended to end stop Move both switches to the reset position Press the control command briefly Move the canopy to the required end limit when extended Move the switch with the rotation arrow for extending the canopy from the reset position to the programming position Then move the canopy up to the upper permanent end stop until the tubular drive switches off automatically The end limits are set Deleting the end limits using the switches a Deleting the end limits individually Note
14. ons or failure to comply with the warning notices e All applicable standards and regulations for the electrical installation must be complied with e Only use spare parts tools and additional equipment which have been approved by the drive manufacturer e Unapproved third party products or modifications to the system and its accessories represent a risk to your safety and the safety of others This means that the utilisation of unapproved third party products or modifica tions which have not been agreed with or approved by us are prohibited We shall not accept liability for dam ages arising from such actions e Before installation shut down all lines and control devices that are not essential for operation e Position control devices within sight of the driven product at a height of over 1 5 m e Stationary mounted control units have to be fixed in sight e Ensure that there is an adequate distance at least 40 cm between moving parts and adjacent objects e Nominal torque and duty cycle must be suitable for the requirements of the driven product e Technical data nominal torque and service life are located on the type plate of the tubular drive e Moveable parts of the drive have to be mounted at a height of more than 2 5 m above ground or on a different level which allows access to the drive e Crushing or shearing points must be avoided or protected e Observe safety distances in accordance with DIN EN 294 e When installing the dr
15. required end limit when the canopy is extended 2 Press the programming button 1 of The tubular drive makes a clack the setting controls for 3 seconds sound to confirm clack Then move the canopy to the required end limit when retracted 2 Now press the programming button 1 The tubular drive makes a clack of the setting controls for 3 seconds sound to confirm clack The end limits are set Wy EN 9 RS soy WS a cs Assembly and Operating Instructions b Point when canopy is extended to end stop Move both switches to the program ming position Move the canopy to the required end limit when the canopy is extended 2 Press the programming button 1 of the setting controls for 3 seconds Then move the canopy up to the upper permanent end stop 2 The end limits are set The tubular drive makes a clack sound to confirm The tubular drive switches off auto matically Deleting the end limits using the setting controls gt 2 clack Action a Delete the end limits individually Move the canopy to the final position which is to be deleted 1 Press the reset button 1 2 Additionally press and hold the downward button 2 3 Now release the reset button 1 but keep the downward button 2 pressed 4 Additionally press the reset button 1 again The final pos
16. roducts especially with regard to end product assembly installation and customer advice Safety Information The following safety instructions and warnings are intended to avert hazards and to prevent damage to property and personal injuries Please retain for future reference Caution Denotes a potentially hazardous situation If this is not avoided injuries may A result Attention Denotes a potentially hazardous situation If this is not avoided the product V or something in its vicinity may be damaged IS Note Denotes user tips and other useful information A Important safety instructions for the user Caution Failure to observe these instructions can lead to serious injuries e All operational work including maintenance and cleaning on electrical installations as well as other parts of the construction must always be performed by authorised specialists especially by qualified electricians e Do not allow children to play with control units e Systems have to be regularly checked by authorised specialists for wear and damages e Always put damaged systems out of operation immediately until they are repaired by an authorised specialist e Do not operate equipment if people or objects are within the danger zone e Observe the danger zone of the equipment during operation e Bring the equipment to a stop and disconnect the mains power supply when maintenance and cleaning jobs are performed either on the system itself or in the immedi
17. sing the end stop systems Safety shutdown in accordance with European engineering directive protection against restarting Optimal adjustment of closing mechanism to suit the system Low maintenance operation of system and drive increases service life Suitable for awnings box awnings screens drop arm awnings and winter garden shades No external limit switch Canopy end limits easy to set by pressing a button on the setting controls or using a switch on the drive Can be fitted on the left or right Several drives can be switched in parallel Suitable for all Becker controls Compatible with earlier motors 4 wire connecting cable With pluggable Becker connecting cable Always observe these assembly and operating instructions when installing and setting the device Warranty Structural modifications and incorrect installation which are not in accordance with these and our other instructions can result in serious injuries e g crushing of limbs Therefore structural modifications should only be carried out with our prior approval and in accordance with our instructions particularly the information contained in these Assembly and Operating Instructions Any further processing of the products which does not comply with their intended use is not permitted The end product manufacturer and fitter have to ensure that all the current statutory official regulations and in particular EMC regulations are adhered to during utilisation of our p
18. stem The changeover time for changing the running direction must be at least 0 5 s Switch and control must not execute simul taneous UP and DOWN commands To operate drives with electronic limit switching only use control elements time controls which do not draw N potential via the drive The outputs of the control element must be potential free in the neutral position Protect the electrical connections from damp Note Ike Becker tubular drives bear the CE mark These drives comply with the valid EU guidelines and meet EMC regulations If the drive is to be operated with units which contain sources of interference the electrician must ensure suitable interference suppression for the relevant devices Disposal This product consists of various materials which must be disposed of correctly Please find out more about relevant national legislations governing the recycling and disposal systems for this product The packaging material must be disposed of correctly Declaration of Conformity Becker tubular drives display the CE mark These drives comply with valid EU directives and meet EMC requirements The complete Declaration of Conformity can be requested from the manufacturer Ce Technical Data Type R8 17C PS Hee R20 17C R30 17C R40 17C R50 11C PS PS PS PS PS Nominal mo o TESES EEN Es Outputspeed min 7 r7 v7 7 7 n Nominal current consumption A 045 050 07 og 115 110 Typ