Home
Operating Instructions Air Conditioner
Contents
1. RSI QUICK GUIDE Panasonic Operating Instructions Air Conditioner Model No Indoor Unit CS E7LKR CS E9LKR CS E12LKR CS E15LKR CS E18LKR CS E21LKR CS E24LKR CS E28LKR Ja LL Outdoor Unit CU E7LKR CU E9SLKR CU E12LKR CU E15LKR CU E18LKR CU E21LKR CU E24LKR CU E28LKR Before operating the unit read these operating instructions thoroughly and keep them for future reference Panasonic HA Air Conditioning M Sdn Bhd 2010 Unauthorized copying and distribution is a violation of law F567536 TABEETORIE ONTENTS This sign warns of injury or damage to The instructions to be followed are classified by the following symbols This symbol denotes an action that is PROHIBITED E These symbols denote an actions that E is COMPULSORY WARNING INDOOR UNIT AND OUTDOOR UNIT ee This appliance is not intended for use by persons including QUICK GUIDE eh pees children with reduced physical sensory or mental capabilities or BACK COVER lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance Please consult authorized dealer or specialist to repair install NOME remove and reinstall the unit Improper installation and handling will cause leakage electric shock or fire The illustrations in this m
2. TP predetermined position The vertical louver swing left right 1 TO TURN ON OR OFF THE UNIT m after the temperature rises 4 e Please be aware of the OFF indication on the remote control display to prevent the unit from starting stopping improperly 2 TO SET TEMPERATURE e Selection range 16 C 30 C e Operating the unit within the recommended temperature could induce energy saving HEAT mode 20 C 24 C COOL mode 26 C 28 C DRY mode 1 C 2 C lower than room temperature 3 TO SELECT OPERATION MODE Remote Control display AUTO mode For your convenience During operation mode selection the power indicator blinks e Unit selects operation mode every 30 minutes according to temperature setting outdoor and room temperature HEAT mode To enjoy warm air e Unit takes a while to warm up The power indicator blinks during this operation COOL mode To enjoy cool air e Use curtains to screen off sunlight and outdoor heat to 2 reduce power consumption during cool mode DRY mode To dehumidify the environment Unit operates at low fan speed to give a gentle cooling operation AIR CONDITIONER 4 TO SELECT FAN SPEED 5 OPTIONS O AUTO gt gt al p anl p aall p atil FAN SPEED e For AUTO the indoor fan speed is automatically adjusted according to the operation mode E7LKR E9LKR E12LKR E15LKR TO MONITOR HU
3. L Faro kona e Can be activated in all modes and can be cancelled by pressing the respective button again QUIET POWERFUL L Como e Cannot be selected at the same time e Cannot be activated during MILD DRY COOLING operation is activated TOSET WHE TIMER 2 sets of ON and OFF timers are available to turn ON or OFF the unit at different preset time e Complete below procedures to set each timer 1 on Gee gt 2 gt Cancel D OFF Gadi Edge e Select ON or OFF timer Confirm e Example of application at living room Morning ON 1 at 07 00 Wake up OFF 1 at 08 00 Out for work Evening ON 2 at 17 00 Back home OFF 2 at 22 00 Sleep To cancel ON or OFF timer press E or to select respective 1 or 2 then press Guia If timer is cancelled manually or due to power failure you can restore the timer again by pressing EN or FF to select respective 1 or 2 then press Set e Upcoming timer will be displayed and will be activated in sequence e When ON Timer is set the unit may start earlier up to 35 minutes before the actual set time in order to achieve the desired temperature on time e Timer operation is based on the clock set in the remote control and repeats daily once set For clock setting please refer to Remote Control Preparation at back cover INDOOR UNIT AN CAUTION Switch off the power su
4. operation 15 minutes of operation it is normal to have the following temperature Water foreign particles have entered the remote difference between air inlet and air outlet vents control _ Cooling 2 8 C Heating 2 14 C Water leaks from Indoor unit e Circuit breaker switches off frequently FOR EXTENDED NON USE Power cord becomes unnaturally warm Activate Heat mode for 2 3 hours as an alternative to remove moisture left in Switches or buttons are not functioning properly the internal parts thoroughly to prevent mould growth e Turn off the power supply e Remove the remote control batteries REMOTE CONTROL TO ADJ UST VERTICAL AIRFLOW DIRECTION _ 5 OPTIONS E ao gt i gt _ I gt A gt A gt A AIR SWING Maximum distances 8m e Keeps the room ventilated e In COOL DRY mode if AUTO is set the louver swing up down automatically In HEAT mode if AUTO is set the louver fix at predetermined position gt INDICATOR PATROL SENSOR 6 TO ADJ UST AIRFLOW DIRECTION 5 OPTIONS POWER PAGE 5 TIMER at Cau gt gt _ gt Io bt I B AIR SWING m POWERFUL gt Bibid ee eee ss MILD DRY COOLING ECO PATROL e Keeps the room ventilated e In COOL DRY mode if AUTO is set the louver swing left right and up down automatically Press the remote control s button In HEAT mode if AUTO is set the horizontal louver fix at f
5. with no warm air supply and louver is closed Indoor fan stops occasionally during heating operation Power indicator blinks before the unit is switched on e The delay is a protection to the unit s compressor e Condensation or evaporation occurs on pipes e The timer setting repeats daily once set e The unit is in defrost mode and AIR SWING is set to AUTO e To avoid unintended cooling effect e This is a preliminary step in preparation for the operation when the ON timer has been set e Changes of temperature cause the expansion contraction of the unit Y YY vvvvyv Y VYY Cracking sound during operation Check the following before calling for servicing SYMPTOM Glee Heating Cooling operation is not working efficiently gt Set the temperature correctly e Close all doors and windows e Clean or replace the filters e Clear any obstruction at the air inlet and air outlet vents e Check if the unit has been installed at an incline e Close the front panel properly Insert the batteries correctly e Replace weak batteries e Check if the circuit breaker is tripped e Check if timers have been set The unit does not receive the signal from the remote e Make sure the receiver not obstructed control e Certain fluorescent lights may interfere with signal transmitter Please consult authorized dealer Noisy during operation Remote control does not work Display is dim or transmission sign
6. MAN PRESENCE amp ACTIVITY FOR ENERGY SAVING ECO ECO 1 gt ECO 2 gt ECO OFF PATROL ula ECO PATROL 4 Set Temperature Set Fan Speed Fan e ECO 1 To optimize comfort and energy saving e ECO 2 To maximize energy saving Applicable during COOL DRY Mode only PATROL SENSOR TO MONITOR AIR QUALITY 3 e Detects air quality e ion operation activates when air quality is at dirty level e Can be activated even when the unit is turned off TO IMPROVE HUMIDITY AND wy NRC aOCIT MOISTURE LEVEL ayn e This operation reduces air dryness and provides you with a comfortable living environment during COOL mode only e When vertical airflow direction is set to AUTO it stops at lower position to avoid cold air contact However you can adjust the louver direction manually TO SWITCH BETWEEN QUIET amp POWERFUL QUIET POWERFUL khua TO ENJ OY QUIET OPERATION sly QUIET e This operation reduces airflow noises 74 TO REACH TEMPERATURE QUICKLY vi e This operation will stop automatically after 4 hours POWERFUL 4 E18LKR E21LKR E24LKR E28LKR 0006 Press and hold for 5 seconds to dim or restore the unit s indicator brightness Press and hold for approximately 10 seconds to show temperature setting in C or F Press to restore the remote control s default setting Not used in normal operations NOMES QUIET POWERFUL gt
7. OOR UNIT Do not use modified cord joint con Do not wash the indoor unit with water benzene thinner cord extension cord or unspecified SY or scouring powder cord to prevent overheating and Do not use for other purpose such as preservation of food Do not share the same power outlet with other Do not use any combustible equipment in front of the equipment to prevent overheating and fire airflow outlet to avoid propagation fire Do not operate with wet hands to prevent electric shock If the supply cord is damage it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard It is strongly recommended to be installed with Earth Leakage Circuit Breaker ELCB or Residual Current Device RCD to prevent electric shock or fire This equipment must be earthed to prevent electrical shock or fire Do not expose yourself directly to cold air for a long period Do not sit or step on the unit you may fall down accidentally ey Do not touch the sharp aluminium fin sharp parts may cause injury SY Do not switch ON the indoor unit when waxing the floor After waxing aerate the room properly before operating the unit Do not install the unit in oily and smoky areas Ensure drainage pipe is connected properly Otherwise leakage may occur Aerate the room regularly Stop using the product when any After long period of use make sure the installation rack abnormality failur
8. a nO _v_ _ a C _TEmp ne gob are oo QUIET POWERFUL C5 Ia ore C7 e TIMER AC RC SET CHECK CLOCK RESET SET CHECK CLOCK RESET Select the desired temperature E7LKR E9LKR E18LKR E21LKR E12LKR E15LKR E24LKR E28LKR Information for Users on Collection and Disposal of Old Equipment and used Batteries Information on Disposal in other Countries Note for the battery symbol bottom two outside the European Union symbol examples These symbols are only valid in the European This symbol might be used in combination with Union If you wish to discard these items please a chemical symbol In this case it complies with EE contact your local authorities or dealer and ask the requirement set by the Directive for the for the correct method of disposal chemical involved Pb Panasonic Corporation o Website http panasonic net Printed in Malaysia OSSC1003 00 F567536
9. al is weak The unit does not work vY vV Yy 7y PATROL operation does not work P Press and hold Patrol for 15 seconds until beep sound is heard press again Patrol sensor indicator on the indoor unit is blinking gt Press twice If the patrol sensor indicator still blinking please consult authorized dealer Notes on ECO PATROL SENSOR Sensor may not detect moving objects further than 7m away or beyond detection angle e Sensor sensitivity is influenced by indoor unit location movement speed temperature range etc e The sensor may mistakenly detects pets sunlight certain lighting fluttering curtains and light reflection as human being The unit stops and the timer indicator blinks Use remote control to retrieve error code 1 Ae i Press until you hear Note beep sound then e For certain errors you write down the error may restart the unit for seconds to 3 9 beeps during operation quit checking SET CHECK CLOCK RESET starts 4 Turn the unit off and reveal the error code to authorized dealer QUICK GUIDE Remote Control Preparation Press and pull out Insert AAA or R03 batteries can be used 1 year Press CLOCK Set time Confirm aQaAQHOfN Close the cover e gt e SET CHECK CLOCK RESET AIR CONDITIONER AIR CONDITIONER E 04 AUTO c Ic AUTO gt HEAT DRY lt COOL Select the desired mode 17 0797 AUTO ecu FAN im gg
10. anual are for Do not install the unit in a potentially explosive or flammable explanation purposes only and may atmosphere Failure to do so could result in fire differ from the actual unit It is subjected E PE E E to change without notice for future a bia ie han A a in a Y m e conditioner indoor or outdoor unit rotating parts may EX cause injury Do not touch the outdoor unit during lightning it may cause electric shock REMOTE CONTROL Do not allow infants and small children to play with the remote control to prevent them from accidentally swallowing the batteries Indoor Remote Unit Air Inlet Control Air Outlet Aa KS OPERATION EONDITGION Use this air conditioner under the following temperature range o Indoor Temperature C sate Min 16 1 mame Max_ 30 Min 16 Temperature C COOLING Min 16 11 ce Min 15 16 DBT Dry bulb temperature 7 oe WBT Wet bulb temperature eo ARYA Outlet SAFETY PRECAUTIONS Thank you for purchasing To prevent personal injury injury to others or property damage please Panasonic Air Conditioner comply with the following Incorrect operation due to failure to follow instructions below may cause harm or damage the seriousness of which is classified as below WARNING This sign warns of death or serious injury JN wanne N carrion POWER SUPPLY INDOOR UNIT AND OUTD
11. e occurs and disconnect is not deteriorate to prevent the unit from falling down the power plug or turn off the power switch REMOTE CONTROL and breaker Risk of smoke fre electric shock The ELCB trips frequently Buring smell is observed 0 Remove the batteries if the unit is not going to be used Prevent electric shock by switching off the power supply when Before cleaning or servicing Extended non use Abnormally strong lightning activity Do not use rechargeable Ni Cd batteries It may damage the remote control Abnormal noise or vibration of the unit is for a long period of time observed Examples of Water leaks from the indoor unit abnormality Power cord or plug becomes abnormally hot failure Fan speed cannot be controlled The unit stops running immediately even if it is switched on for operation The fan does not stop even if the operation is stopped New batteries of the same type must be inserted following the polarity stated to prevent malfunction of the remote control Contact immediately your local dealer for maintenance repair INFORMATION FOR SEASONAL INSPECTION AFTER EXTENDED NON USE NON SERVICEABLE CRITERIAS e Checking of remote control batteries TURN OFF POWER SUPPLY then please consult e No obstruction at air inlet and air outlet vents authorized dealer under the following conditions Use Auto OFF ON button to select Cooling Heating operation after Abnormal noise during
12. le E18LKR E21LKR E24LKR E28LKR e Do not adjust by hand AUTO OFF ON BUTTON Use when remote control is misplaced or a malfunction occurs Auto Press once Auto Press and hold until 1 beep is heard then release Press and hold until 1 beep is heard then release Heating Press again until 2 beeps then release Press the button to turn off 9 e ion CHARGING WIRE e ion FILTERS e Clean the filters regularly e Wash rinse the filters gently with water to avoid damage to the filter surface Dry the filters thoroughly under the shade away from fire or direct sunlight e Replace any damaged filters 11 ACTIVE e ion GENERATOR Clean with dry cotton bud e Active e ion generator cleaning is recommended every 6 months TROUBLESHOOTING The following symptoms do not indicate malfunction SYMPTOM _ H CAUSE Mist emerges from indoor unit e Condensation effect due to cooling process Water flowing sound during operation e Refrigerant flow inside the unit The room has a peculiar odour e This may be due to damp smell emitted by the wall carpet furniture or clothing e This helps to remove the surrounding odours Indoor fan stops occasionally during automatic fan speed setting Operation is delayed a few minutes after restart Outdoor unit emits water steam Timer indicator is always on Power indicator blinks during HEAT mode
13. pply before cleaning eDo not touch the aluminium fin sharp parts may cause injury CLEANING INSTRUCTIONS e Do not use benzene thinner or scouring powder e Use only soap pH7 or neutral household detergent Do not use water hotter than 40 C HINT To ensure optimal performance of the unit cleaning maintenance has to be carried out at regular intervals Dirty unit may cause malfunction and you may see error code H99 Please consult authorized dealer 9 10 D ah PURIFYING S e Do not touch during operation ECO PATROL SENSOR Do not hit or violently press the sensor or poke it with a sharp object This can lead to damage and malfunction Do not place large objects near the sensor and keep away heating units or humidifiers from the sensor s detection area This may lead to sensor malfunction 1 INDOOR UNIT e Wipe the unit gently with a soft dry cloth 7 VERTICAL AIRFLOW DIRECTION LOUVER Do not adjust by hand 2 FRONT PANEL Remove Front Panel e Raise and pull to remove the front panel e Wash gently and dry Close Front Panel e Press down both ends of the front panel to close it securely 3 REMOTE CONTROL RECEIVER 4 ALUMINIUM FIN 5 ECO PATROL SENSOR 6 HORIZONTAL AIRFLOW DIRECTION LOUVER E7LKR E9LKR E12LKR E15LKR e Manually adjustab
Download Pdf Manuals
Related Search
Related Contents
Istruzioni per l`uso Bondex Standard Cerámica Rápido Logitech T631 User's Manual Luftbefeuchter LB 5 Gebrauchsanweisung 4 Instructions for use 10 Tripp Lite Cat6 Gigabit Snagless Molded Patch Cable (RJ45 M/M) - Blue, 10-ft. INTRODUCTION User's Guide microline busmaster BSP Radio Shack 63-994 User's Manual Copyright © All rights reserved.
Failed to retrieve file