Home

Installation Manual

image

Contents

1. Ct ciicirtay PV ezRack SolarRoof Klip Lok Interface Code Compliant Planning and Installation Complying with AS NZS1170 2 2011 AMDT 2 2012 CONTENT Mee UNUM caccsrrszra casera ead ig arev cate noe ones dancanecctneserneriera tue tbeee causa caunaasaedevaaievacien ie 2 2 COMPONE Fe C Generis nent erent Pee E ee eee meee 3 SB AUPE VIG Ch arsenate apron E E E E 4 e o N C Oa E E E E A E amet maginneeeuaentaaataaes 13 Page 1 of 16 Installation Guide_PV ezRack_SolarRoof_Klip Lok_AU_V2 1 docx 18 20 Duerdin St Tel 61 3 9017 6688 Clayton VIC 3168 Australia Fax 61 3 9017 6668 www clenergy com au Email sales clenergy com au ren CLENER G Y Introduction The Clenergy PV ezRack SolarRoof Klip Lok type interface has been developed as a non penetrating solution for concealed roofs The interface can be attached on different type of profiles of concealed roof to mount panels directly or in conjunction with L feet tilt legs or SolarTripod Please review this manual thoroughly before installing PV ezRack SolarRoof This manual provides 1 supporting documentation for building permit applications relating to PV ezRack SolarRoof Universal PV Module Mounting System and 2 planning and installation instructions The PV ezRack SolarRoof parts when installed in accordance with this guide will be structurally adequate and will meet the AS NZS1170 2 2011AMDT 2 2012 standard During installation and especially
2. J N 43mm E t Overlap Pan Central Pan Underlap Pan 700mm 4mm Cover Speed Deck Ultra 42 mem rm t 233mm E pi KingKlip 700 406mm coverage Installation Guide_PV ezRack_SolarRoof_Klip Lok_AU_V2 1 docx Page 7 of 16 18 20 Duerdin St Tel 61 3 9017 6688 Clayton VIC 3168 Australia Fax 61 3 9017 6668 www clenergy com au Email sales clenergy com au re CLENERGY Klip lok 406 4 Determine the height of your installation site This document provides sufficient information for the PV ezRack SolarRoof system installation up 20 meter height If your installation site is more than 20 meters please contact Clenergy to obtain additional engineering certificate to support your installation 5 Determine Roof slope The PV ezRack SolarRoof system can be used for roof slope up to 60 degrees Please verify that the Installation site roof slope is between 0 and 60 degrees 6 Determine the maximum Klip Lok interface spacing a Direct Mounting or using L feet and rails Please use the following table to determine the Maximum Klip Lok interface spacing mm PV panel length 1580mm Max panel weight 15 kg m Roof Angle up to 30 Terrain Category 3 e On top of the purlin WIND REGION A B Qu K Pa 065 080 075 084 084 102 090 110 083 109 O96 12 106 140 114 150 hz 50m 10 0 m 15 0 m 20 0 m 50m 10 0 m 150m 20 0 m Angle 15 lt 30 s15 lt 30 15 lt 30 s15 s0 s15 lt 30
3. and other products you use are appropriate for the particular installation and the installation environment Ensuring that the roof its rafters connections and other structural support members can support the array under building live load conditions this total assembly is hereafter referred to as the roof rafter assembly Using only genuine PV ezRack parts substitution of parts may void the warranty and invalidate the letter of certification Ensuring that the concealed roof profile installed on the roof have been identified and is one that is accredited and tested Ensuring the Klip Lok interface fit strongly to the roofing sheet Ensuring safe installation of all electrical aspects of the PV array This document is designed to support for installations using Clenergy Klip Lok type interface and PV ezRack SolarRoof or SolarTripod PV Module Mounting System manufactured by Clenergy Xiamen Technology Co Ltd Follow the six steps below and the installation instructions section to install this product in compliance with the AS NZS1170 2 2011 AMDT 2 2012 Before proceeding note the following Installation Guide_PV ezRack_SolarRoof_Klip Lok_AU_V2 1 docx 18 20 Duerdin St Clayton VIC 3168 Australia www clenergy com au This document addresses only wind loads on the assumption that wind produces the maximum load factor affecting an installation Verify that other local factors such as snow loads and earth quake effects do n
4. s15 lt 30 lt 15 s30 lt 15 lt 30 Force kN m 0 57 0 70 0 65 0 73 0 73 0 89 0 78 0 96 0 73 0 96 0 84 1 10 WIND REGION c KlipLok Type Capacity Qu Kea 1 27 2 19 147 231 1 63 257 1 75 275 kN hz 5 0 m 10 0 m 15 0m 20 0 m Lysaght 406 1 37 Angle lt 15 sw 15 30 15 s30 lt 15 sw Lysaght 700 1 17 Fielders 700 0 5 Stramit SDU 18 qu ultimate wind pressure Force kKNim 4 11 1 91 128 202 142 225 1 53 2 40 Notice KingKlip is Fielders KlipLok Installation Guide_PV ezRack_SolarRoof_Klip Lok_AU_V2 1 docx Page 8 of 16 18 20 Duerdin St Tel 61 3 9017 6688 Clayton VIC 3168 Australia Fax 61 3 9017 6668 www clenergy com au Email sales clenergy com au Ct Cciicirtay e Anywhere on the roof WIND REGION A B kPa 065 O80 O75 084 084 1 02 114 1450 Ne 5 0m 10 0 m 15 0 m 20 0 m s15 lt 30 Force kN m 0 84 WIND REGION c KlipLok Type Qu Kpa 127 249 147 231 163 257 175 275 z 5 0m 10 0 m 15 0 m 20 0 m Lysaght 406 Angie 215 s30 s15 s30 s15 lt 30 15 lt 30 Lysaght 700 0 67 Fielders 700 0 43 Stramit SDU 0 73 qu ultimate wind pressure Force kN m 1 11 1 91 1 28 2 02 1 42 2 25 1 53 2 40 Notice KingKlip is Fielders KlipLok For PV panel length over 1580mm up to 1700mm reduce the spacing by 6 For PV panel length over 1700mm up to 1800mm reduce the spacing by 11 5 For PV panel length over 1800mm up to 2000mm reduce the spacing by 21 The abov
5. DU 48 gu ultimate wind pressure Force kNm 0 75 129 O87 137 097 152 1 04 1 63 Notice KingKlip is Fielders KlipLok o Anywhere on the roof WANO REGION O O O G KlipLok Type Capacity wo 127 209 147 231 163 257 175 275 kN a A VOR RS a _ R _ nyoogt 405 04 Angie s15 30 s15 lt 30 s15 s30 s15 30 Lysaght 700 0 87 Fielders 700 0 43 Stramit SDU 0 73 qu ultimate wind pressure Force kKNim 0 75 129 087 437 097 1 52 1 04 1 63 Notice KingKlip is Fielders KlipLok e For PV panel length over 1580mm up to 1700mm reduce the spacing by 6 e For PV panel length over 1700mm up to 1800mm reduce the spacing by 11 5 Installation Guide_PV ezRack_SolarRoof_Klip Lok_AU_V2 1 docx Page 12 of 16 18 20 Duerdin St Tel 61 3 9017 6688 Clayton VIC 3168 Australia Fax 61 3 9017 6668 www clenergy com au Email sales clenergy com au Ct ciicirtay e For PV panel length over 1800mm up to 2000mm reduce the spacing by 21 e The above table are based on ER R T50 ER I O9 and ER S TRI S pull out Capacity e The last Klip Lok interface shouldn t be installed closer than 225mm from the end of the tripod leg e The above table are based on fixing anywhere on the roof including the edges e The base of the tripod have to be fixed using 2 M8 bolt per Klip Lok type interface e Angle refers to the angle between the roof and the panels not to the horizontal e on pur
6. cCLENERGY o Anywhere on the roof Not suitable e With 3 Klip Lok interfaces per leg o On top of the purlin WIND REGION A 8 quer 065 080 075 084 O84 toz O90 60838108 09 126 108 140 1414 150 h 50m 10 0 m 15 0 m 20 0 m 50m 10 0 m 150m 20 0 m Age s 5 s30 s15 30 s5 30 s15 s30 s15 30 515 lt 30 s15 s30 s15 s30 Force kN im 0 83 1 02 096 1 07 07 t31 1 15 tat 1 07 140 123 1 61 1 36 180 146 t 93 WINO REGION c KiipLok Type Capacity qu Kpa 1 27 249 147 231 163 257 1 75 275 kN hz 50m 100m 15 0m 20 0 m Lysaght 406 1437 Angie s15 s30 s15 s30 s15 30 s15 s30 Lysaght 700 1 17 Fielders 700 0 5 Stramit SDU 18 qu ultimate wind pressure Force kN m 163 2 80 1 88 296 200 3 2 25 3 53 Notice KingKiilp is Fielders KlipLok o Anywhere on the roof WINO REGION A 6 Qu K Pa 0 65 0 80 0 75 0 64 0 84 1 02 0 90 1 10 0 83 1 09 0 96 126 1 06 1 40 1 14 1 450 h 5 0m 10 0 m 15 0 m 20 0 m 50m j 10 0 m 15 0 m 20 0 m Ange s15 s30 s15 s30 s15 lt 30 lt 15 lt 30 lt 15 s30 83s 15 s30 s15 s30 s15 30 Force kW m 083 102 0 96 107 1 07 1 31 1 15 141 1 07 1 40 1 23 1 61 1 36 180 1 46 1 93 WIND REGION c KlipLok Type Capacity qu Kew 127 249 147 231 163 257 1 75 275 kN he 5 0m 10 0 m 15 0 m 20 0 m Lysaght 406 0 4 Angie siS lt 30 s15 S30 15 530 s15 30 Lysaght 700 0 87 Fielders 700 0 43 Stramit SDU 073 qu ultimate w
7. when working on the roof please comply with the appropriate occupational health and safety regulations Please also pay attention to other relevant regulations of your local region Please check that you are using the latest version of the installation manual which you can do by contacting Clenergy Australia via email on sales clenergy com au or contacting your local distributor in Australia Installation Guide_PV ezRack_SolarRoof_Klip Lok_AU_V2 1 docx Page 2 of 16 18 20 Duerdin St Tel 61 3 9017 6688 Clayton VIC 3168 Australia Fax 61 3 9017 6668 www clenergy com au Email sales clenergy com au Ct ci iciray Component list Tin Interface Klip lok type L Feet interface with Z Module End Clamp Inter Clamp PV ezRack oe Tilt leg Front Standard Rail i Foot PV ezRack Standard Splice Tilt leg Back Leg SolarTripod Double Support SolarTripod Single Suppot Splice for T T rail 50 rail 50 M8 25 Hex head bolt Installation Guide_PV ezRack_SolarRoof_Klip Lok_AU_V2 1 docx Page 3 of 16 18 20 Duerdin St Tel 61 3 9017 6688 Clayton VIC 3168 Australia Fax 61 3 9017 6668 www clenergy com au Email sales clenergy com au yens CLENER GY Planning The installer is solely responsible for Complying with all applicable local or national building codes and Clean Energy Council guidelines including any that may superseded this manual Ensuring that PV ezRack SolarRoof
8. 17 6688 Clayton VIC 3168 Australia Fax 61 3 9017 6668 www clenergy com au Email sales clenergy com au CLENCERGY WIND REGION A B qu amp Fa 065 080 O75 0s 084 1 02 0 90 110 083 109 0 96 1 26 1 06 1 40 1 14 1 50 hs 50m 10 0 m 150m 200m 5 0m om 50m om Arge lt 15 lt 30 s15 s3 s15 30 s15 SOS 30 s15 s30 s15 30 s15 33 Force kNim 0 57 0 70 0 65 0 73 0 73 089 097 1 19 0 73 0 86 0 64 1 10 0 93 1 23 0 99 137 WIND REGION c Kliplok Type Capacity qu Kpa 1 27 2 19 147 231 1 63 2 57 1 75 2 75 KN he 5 0m 10 0 m 150m 20 0m Lysag 406 0 4 Arga s15 s30 s15 lt 30 s15 30 s15 s30 Lysaght 700 0 87 Fielders 700 0 43 Stramit SDU 0 73 qu ultimate wind pressure Force kNim 1 11 101 1 28 2 02 142 225 183 2 40 Notice KingKlip is Fielders KlipLok e With 3 Klip Lok type interfaces per leg o On top of the purlin WIND REGION A B quakes 065 080 075 084 084 102 0 90 110 083 109 09 1 26 1 06 140 114 1 50 he 5 0m 100m 15 0 m 40 0 m 50m 10 0 m 150m 20 0 m Ange 315 s30 s15 s30 si5 330 s15 s0 siS s30 si5 30 s15 0 s15 30 Force kNim 038 047 044 050 050 061 066 081 049 065 O57 075 063 083 067 089 WIND REGION c KlipLok Type Capacity Qu Kew 127 219 147 231 163 257 475 275 kN hz 5 0m 100m 150m 20 0 m Lysaght 406 137 Angie s15 lt 0 s15 30 s15 s30 185 lt 30 Lysaght 700 14 17 Fielders 700 05 Stamt
9. e table are based on ER R ST and ER I 09 pull out capacity The above table are based on fixing anywhere on the roof including the edges The panels or L foot have to be fixed using 1 M8 bolt on purlin means that the distance from the purlin to the Klip Lok interface centre to centre is less than 100mm Angle refers to roof angle b Using Clenergy adjustable tilt legs Please use the following table to determine the Maximum Klip Lok type interface spacing mm PV panel length 1580mm Max panel weight 15 kg m Tilt Angle up to 30 Terrain Category 3 Installation Guide_PV ezRack_SolarRoof_Klip Lok_AU_V2 1 docx Page 9 of 16 18 20 Duerdin St Tel 61 3 9017 6688 Clayton VIC 3168 Australia Fax 61 3 9017 6668 www clenergy com au Email sales clenergy com au Ct Cciiciiray e On top of the purlin WIND REGION A B Qu K Pa 065 080 075 084 084 1 02 0 90 110 O83 109 696 1 26 1 06 1 40 1 14 1 50 hz 5 0m 10 0 m 15 0m 20 0 m 5 0m 10 0 m 15 0 m 20 0 m s0 sis s330 s5 lt 3 s15 s0 s65 20 i5 lt 30 s15 30 s5 lt 30 s15 0 57 0 70 0 73 073 0 65 0 89 119 073 O86 0 84 WIND REGION C KlipLok Type Qu Kpa 127 219 147 231 163 257 1 75 2 75 he 5 0m 10 0 m 15 0 m 20 0 m Lysaght 406 Angle s15 lt 30 lt 15 lt 30 lt 15 lt 30 lt 15 lt 30 Lysaght 700 Fielders 700 Stramit SDU Force kN m 1 11 191 128 202 142 2 25 1 53 2 40 e Anywhere on the r
10. g out of the use of the Product by Purchaser under any circumstances If within the specified Warranty periods the Product shall be reasonably proven to be defective then Clenergy shall repair or replace the defective Product or any part thereof in Clenergy s sole discretion Such repair or replacement shall completely satisfy and discharge all of Clenergy s liability with respect to this limited Warranty Under no circumstances shall Clenergy be liable for special indirect or consequential damages arising out of or related to use by Purchaser of the Product Manufacturers of related items such as PV modules and flashings may provide written warranties of their own Clenergy s limited Warranty covers only its Product and not any related items Installation Guide_PV ezRack_SolarRoof_Klip Lok_AU_V2 1 docx Page 16 of 16 18 20 Duerdin St Tel 61 3 9017 6688 Clayton VIC 3168 Australia Fax 61 3 9017 6668 www clenergy com au Email sales clenergy com au
11. hall be obtained by linear interpolation between the values for the TC2 and TC3 in table 4 1 Terrain Category 3 TC3 Terrain with numerous closely spaced obstruction having heights generally from 3m to 10m The minimum density f obstructions shall be at least the equivalent of 10 house sizes obstructions per hectare e g suburban housing or light industrial estates Terrain Category 4 TC4 Terrain with numerous larger high 10m to 30m tall and closely spaced constructions such as large city centres and well developed industrial complexes In this installation manual we have used terrain category 3 if it is outside of this please refer to the accreditation letter Installation Guide_PV ezRack_SolarRoof_Klip Lok_AU_V2 1 docx 18 20 Duerdin St Clayton VIC 3168 Australia www clenergy com au Page 6 of 16 Email sales clenergy com au Tel 61 3 9017 6688 Fax 61 3 9017 6668 Ct ciicirtay 3 Determine the type of concealed roof The best way to identify the type of concealed roof installed is to check the label normally located underneath the roofing sheet Otherwise you can contact the builder or check the building plan to find out the exact type of the roofing sheet WARNING THE USE OF THE KLIP LOK TYPE BRACKET IS NOT ACCREDITED ON ANY OTHER ROOF TYPES THAN THE FOUR LISTED BELOW Overlap Underlap a w 3 i 43 mm x i t _ 700 mm cover _ Klip lok 700 Overlap RB Central Ribs Underlap Rib Vy
12. ill need to determine the terrain category that is most applicable to the installation Note Terrain Category 1 TC1 Very exposed open terrain with few or no obstructions and enclosed limited sized water surfaces at serviceability and ultimate wind speeds in all wind regions e g flat treeless poorly grassed plains rivers canals and lakes and enclosed bays extending less than 10km in the wind direction Terrain Category 1 5 TC1 5 Open Water surfaces subjected to Shoaling waves at serviceability and ultimate wind speeds in all win regions e g near shore ocean water larger unenclosed bays on seas and oceans lakes and enclosed bays extending greater than 10km in the wind direction The terrain height multipliers for this terrain category shall be obtained by the linear interpolation between the values for the TC1 and TC2 in table 4 1 Terrain Category 2 TC2 Open terrain including grassland with well scattered obstructions having heights generally from 1 5m to 5m with no more than two obstructions per hectare e g farmland and cleared Subdivisions with isolated trees and uncut grass Terrain Category 2 5 TC2 5 Terrain with a few trees or isolated obstructions This category is intermediate between TC2 and TC3 and represents the terrain in developing outer urban areas scattered houses or larger acreage developments with fewer than ten buildings per hectare The terrain height multipliers for this terrain category s
13. ind pressure Force kN m 163 280 188 296 209 3 30 2 25 353 Notice KingKlip is Fielders KlipLok e For PV panel length over 1580mm up to 1700mm reduce the spacing by 6 e For PV panel length over 1700mm up to 1800mm reduce the spacing by 11 5 Installation Guide_PV ezRack_SolarRoof_Klip Lok_AU_V2 1 docx Page 14 of 16 18 20 Duerdin St Tel 61 3 9017 6688 Clayton VIC 3168 Australia Fax 61 3 9017 6668 www clenergy com au Email sales clenergy com au ren CLENER GY e For PV panel length over 1800mm up to 2000mm reduce the spacing by 21 e The above table are based on ER R T50 ER I O9 and ER S TRI S pull out Capacity e The last Klip Lok type interface shouldn t be installed closer than 500mm from the end of the tripod leg e The above table are based on fixing anywhere on the roof including the edges e The base of the tripod has to be fixed using 2 M8 bolt per Klip Lok type interface e Angle refers to the angle between the roof and the panels not to the horizontal e on purlin means that the distance from the purlin to the Klip Lok interface centre to centre is less than 100mm Installation Guide_PV ezRack_SolarRoof_Klip Lok_AU_V2 1 docx Page 15 of 16 18 20 Duerdin St Tel 61 3 9017 6688 Clayton VIC 3168 Australia Fax 61 3 9017 6668 www clenergy com au Email sales clenergy com au ren CLENER GY 1 Service 10 year limited Product Warranty 5 year limited Finish Warranty Clenergy co Ltd warrant
14. lin means that the distance from the purlin to the Klip Lok interface centre to centre is less than 100mm d Using Clenergy PV ezRack SolarTripod Double AMN Please use the following table to determine the Maximum Klip Lok type interface Support Spacing mm PV panel length 1580mm Max panel weight 15 kg m Tilt Angle up to 30 Terrain Category 3 e With 2 Klip Lok interfaces per leg o On top of the purlin WIND REGION A B akea 065 O80 O75 084 O84 102 090 110 O83 109 O96 126 106 140 1i 4150 Ne 50m 10 0 m 15 0 m 20 0 m 50m 10 0 m 15 0 m 20 0 m yh 5 ZZ sis 230 lt 8 0 15 sco Age 315 20 lt 15 230 s15 lt 30 215 20 lt 15 20 e Force kNim 123 15t 141 159 388 194 189 57 207 181 238 200 265 215 284 WIND REGION EIEE Ss PAi Kliplok Type Capacity aa tar 219 147 231 163 257 175 275 kN he 50m 10 0 m 15 0 m 20 0 m Lysaght 406 1 37 Angle lt 15 20 15 20 15 s30 s15 6530 Lysaght 700 1 7 Fielders 700 OS Stramit SDU 1 8 Stramit SOU 0 430 i qo 4 i J 240 qu ultimate wind pressure Force kNim 2 40 413 277 437 308 486 332 521 Notice KingkKlip is Fielders KlipLok Installation Guide_PV ezRack_SolarRoof_Klip Lok_AU_V2 1 docx Page 13 of 16 18 20 Duerdin St Tel 61 3 9017 6688 Clayton VIC 3168 Australia Fax 61 3 9017 6668 www clenergy com au Email sales clenergy com au
15. oof WIND REGION A Qu K Pa 065 080 075 084 084 1 02 0 90 1 10 083 109 0 95 hz 5 0m 10 0 m 15 0m 20 0 m 5 0m lt 30 415 s30 s15 s30 s15 430 s15 430 415 s15 __ Angle 0 57 0 70 0 65 0 89 0 73 0 96 0 84 Force kN m 073 0 73 WIND REGION c KlipLok Type Qu Kps 127 219 147 231 163 257 175 275 hz 50m 0am 15 0 m 20 0 m Lysaght 406 Angle s15 lt 30 s15 630 s15 530 s15 30 Lysaght 700 Fielders 700 Stramit SDU Force kN m 10 0m 0 93 1 23 0 99 1 31 me i 1 37 1 17 0 5 1 8 qu ultimate wind pressure Notice KingKlip is Fielders KlipLok B 1 26 1 06 140 1 14 1 50 15 0 m 20 0 m s30 415 s30 415 430 1 10 0 93 123 0 99 1 31 Capacity KN 0 4 0 87 0 43 0 73 qu ultimate wind pressure 191 1 28 202 142 225 153 240 Notice KingKlip is Fielders KlipLok e For PV panel length over 1580mm up to 1700mm reduce the spacing by 6 e For PV panel length over 1700mm up to 1800mm reduce the spacing by 11 5 e For PV panel length over 1800mm up to 2000mm reduce the spacing by 21 e The above table are based on ER R ST ER I 09 and ER TL10 15 and 15 30 pull out capacity The above table are based on fixing anywhere on the roof including the edges e The feet of the tilt legs have to be fixed using 2 M8 bolt e Angle refers to the angle between the roof and the panels not to the horizontal e on purlin means that the distance from the purlin to the Klip Lok in
16. orawa A Region A1 simm Aioom t Lore Mowe istand yi Greer Gunyigi Mead Parth A yane gt 33 200 im y v any Mount Gambier 0 70 km a 50 ken Regions ar marked with the letters Region AS i A At to ASL 8S C moo within 70 km esi bon border Coastal Region boundaries are of Melbourne GPO Geelong p aa smooth bass set in from a smoulhed amp o coastiine by 50 100 150 anc 200 km islands withes 50 km of the coos ere the same Region as the ecjecent coast Region A3 E Mother Region Definition Wind regions are pre defined for all of Australia by the Australian Standard 1170 2 The Wind Region is an independent factor of surrounding topography or buildings e Most of Australia is designated Region A which indicates a Regional Ultimate Basic Wind Velocity of 45m s e Some areas are designated Region B 5 7m s Local authorities will advise if this applies in your area e Region C areas 66m s are generally referred to as Cyclonic and are generally limited to northern coastal areas Most Region C zones end 100km inland e Region D 80m s Australia s worst Cyclonic Region between Carnarvon and Pardoo in Western Australia Installation Guide_PV ezRack_SolarRoof_Klip Lok_AU_V2 1 docx Page 5 of 16 18 20 Duerdin St Tel 61 3 9017 6688 Clayton VIC 3168 Australia www clenergy com au Email sales clenergy com au Fax 61 3 9017 6668 ren CLENER GY 2 Determine the Terrain Category You w
17. ot exceed the wind loads Give precedence to any factor that does Wind loads are considered to act on the entire projected area or may be perpendicular to any surface The roof on which the PV ezRack SolarRoof will be installed must have the capacity to resist the combined Design Dead Load and Live Load per footing To determine the parts Bill of material you need you can use our PV ezRack SolarRoof Calculator Page 4 of 16 Tel 61 3 9017 6688 Fax 61 3 9017 6668 Email sales clenergy com au Ct ciriciray 1 Determine the wind region of your installation site 142 Region B Chrismas isang Region B Region C L Australian Territory only Region 8 O pan sO n ad MoPDonnell Crees Cocos tsliands Daran Fie Region Moretoe Region r Wijndham IC a Mar wada 50 km Region C 100 khm yr Borroloola Sa SPERA O ta j Kunurruri a Dunder mu gt West Moretang Atherton oe Burketown T i al R ure oansvite Port Hedland i Broome gt 2o Kareatha Croydon Collinsville 20 ay Rockhampton Onslow Marbio Bar Alce pr ings fi gt ioee i Mitstream Sundsberg Region D Sh Region C _ a Carnarvon Region B ew Gascoyne Junction Region A4 Grech 25 BS Toowoomba at woene i Cebytharra yf Kyogie yog e Goring Norfolk Istendgs q7 Mlawa a Region 6 L Bourke 39 eS M
18. s to the original purchaser Purchaser of product s that it manufactures Product at the original installation site that the Product shall be free from defects in material and workmanship for a period of ten 10 years except for the anodised finish which finish shall be free from visible peeling or cracking or chalking under normal atmospheric conditions for a period of five 5 years from the earlier of 1 the date the installation of the Product is completed or 2 30 days after the purchase of the Product by the original Purchaser Finish Warranty The Finish Warranty does not apply to any foreign residue deposited on the finish All installations in corrosive atmospheric conditions are excluded The Finish Warranty is VOID if the practices specified by AAMA 609 amp 610 02 Cleaning and Maintenance for Architecturally Finished Aluminium www aamanet org are not followed by Purchaser This Warranty does not cover damage to the Product that occurs during its shipment storage or installation This Warranty shall be VOID if installation of the Product is not performed in accordance with Clenergy s written installation instructions or if the Product has been modified repaired or reworked in a manner not previously authorized by Clenergy IN WRITING or if the Product is installed in an environment for which it was not designed Clenergy shall not be liable for consequential contingent or incidental damages arisin
19. terface centre to centre is less than 100mm Installation Guide_PV ezRack_SolarRoof_Klip Lok_AU_V2 1 docx 18 20 Duerdin St Clayton VIC 3168 Australia www clenergy com au Page 10 of 16 Tel 61 3 9017 6688 Fax 61 3 9017 6668 Email sales clenergy com au cCLENERGY c Using Clenergy PV ezRack SolarTripod Single A A ays amp 1350 ad Please use the following table to determine the Maximum Klip Lok interface spacing mm PV panel length 1580mm Max panel weight 15 kg m Tilt Angle up to 30 Terrain Category 3 e With 2 Klip Lok interfaces per leg o On top of the purlin WIND REGION A B Qu K Pa 065 080 O75 O84 0 84 102 090 1 10 083 109 0 9 1 26 1 06 140 114 1 50 he 50m 100m 150m 20m 50m 00m 150m 20 0m Ange s15 s30 s15 lt 30 s15 lt 30 s15 s0 lt 15 s30 315 s30 s15 s30 s15 s30 Force kNim 0 57 0 70 065 073 073 O88 OF 119 073 096 0 110 O98 123 099 131 WIND REGION c Kliplok Type Capacity Qu Kpa 127 219 147 231 183 257 1 75 2 75 kN hz 5 0m 100m 15 0 m 20 0 m Lysaght 406 1 37 Ange s15 s30 s15 s30 s15 30 s15 s30 Lysaght 700 1 17 Fielders 700 05 RA Stramit SDU 18 qu ultimate wind pressure Force kNim 1 13 1 91 128 202 1 42 2 25 1 53 2 40 Notice Kingklip is Fielders KlipLok o Anywhere on the roof Installation Guide_PV ezRack_SolarRoof_Klip Lok_AU_V2 1 docx Page 11 of 16 18 20 Duerdin St Tel 61 3 90