Home

IR 641 Installation Manual

image

Contents

1. Minimum distance to wall 2 Minimum ventilation distance 3 Space for recess Distancias minimas a paredes p P wt Ti 00 Distancias minimas de ventilaci n MANTA TABLA AISLANTE SEPARACI N The installation process is the same as for vitroceramic hobs bearing in mind it will be necessary to take greater precautions to ensure improved ventilation for the recess space Ventilation openings will need to be thermally isolated using the insulating blanket supplied with the hob This insulating blanket prevents hot air mixing with the cold air being sucked in Warning This blanket must not cover ventilation outlets preventing the evacuation of air Avoid excessive heat build up in the hob NOTE Induction hobs should not be installed above an oven that does not feature forced ventillation 32 Code N PRM 00 0001 INSTALLER S MANUAL Pevised Date 2006 3 2 FITTING THE HOB TO ITS RECESS Page N 33 of 95 SST AEREO E C Serie Soft plate B How to fit this plate in a 60cm cabinet D 60 cm cabinet E Detail The minimum vertical distance from the hob to the cabinet is 600 mm PIPRPPARAAA AAA Cristal Gas Series The fitting process is identical to that for other models 1 Attach seal J 2 Fix the four clips QG using the two tabs P in the spaces O in the hob 3 Tighten the screws T See illustration 33 C
2. the hob casing For those models which do not include a mains supply cable in order to connect the appliance remove the cover situated underneath the hob in order to gain access to the connection terminal Having successfully connected the appliance replace the cover and secure the mains cable with a jubilee clip in order to prevent pressure on the cable The mains supply cable should be at least the HO5 VVF type Possible electrical connections TR 932 Induction 400 V 3N 400 V 2N7 230 VT 230 V 3 Ea UE i AJA 6 AL Lars ARRAZ ial tele 2011 OH OLTOLIOLI NO ata eo AR odil aa A 4 6 eia ep AZ pren aial age Ch J LE oat i ij 4x 1 5 mm 39 Code N PRM 00 0001 INSTALLER S MANUAL Pevsed Date 2006 4 CONTROL PANEL Page N 40 of 95 4 1 INSTALLATION LUX glass control panels Make an opening in the kitchen cabinet with the following measurements 557 565 mm long 95 110mm high Screw in the two fixing plates so that the shafts can be inserted into the control panel The left hand plaque should be placed in such a way that the semi circle appears on the upper side of the plate whilst the hand side plaque should appear with the semi circle on the lower side of the plate To connect the hob to the control panel insert the hob connector into the back of the panel Exterior measurements of the panel Attach the cardans 997x120mm Insert the panel introducing it from right to left into t
3. Code N PRM 00 0001 INSTALLER S MANUAL Pevised Date 2006 Page N 26 of 95 3 HOBS When fitting a hob installers should bear in mind the following series of important recommendations in order to ensure the safety and correct working of the appliance a During fitting recessed hobs should be handled with care to prevent damage to the edges or the glass surface of vitroceramic models a With vitroceramic models carefully check the glass surface to ensure there are no cracks Should there be even the slightest crack do not proceed with installation a If the hob is to be recessed over an oven carefully follow all specifications indicated to ensure correct ventilation a Before installing ensure that the gas supply characteristics are compatible with the regulations indicated on the specification plate gas type and pressure a Installation and maintenance of the hob should be carried out by qualified personnel in accordance with existing regulations a Cabinet adhesives should be resistant to temperatures of 100 C Y type protection against overheating in compliance with the EN 60335 2 6 standard a Minimum distances between the hob and extractor hood should be strictly observed 65 cm for electric hobs 70 cm for gas and mixed hobs Recess measurements should be similarly observed Recessed hobs with reinforced plates should be installed more than 15 cm away from side walls All other hobs should be install
4. ach time the connecting nut is dismantled the joint should be changed In order to prevent damage to the hob when tightening the nut on the gas supply pipe use a tool with a maximum grip of 350Kgf cm Once the appliance has been connected to the gas check it for leaktightness If you intend to do this with compressed air bear in kind that test pressure should not exceed 200g cm In the event that the test is carried out with gascheck tightness with water and soap NEVER USE A NAKED FLAME Minimum flame adjustment Once the hob has been correctly fitted check that the minimum flame level is well regulated In order to do this light the gas rings and turn the control quickly from maximum to minimum If the flame goes out they will need to be adjusted 38 Code N PRM 00 0001 INSTALLER S MANUAL __Fevsed Date 2006 3 5 ELECTRICAL CONNECTION Page N 39 of 95 Before connecting the hob to the mains supply check that the voltage and frequency correspond to the characteristics on the specification panel situated underneath the appliance Ensure that the connection to the mains supply is at the correct voltage Mains supply should be provided via a suitable omnipolar switch with a 3mm miminum gap between contacts and which can carry the required maximum ampage ensuring that disconnection in case of emergency or appliance cleaning is guaranteed Take care to ensure that the mains supply cable is not in contact with
5. eck that the cardans are correctly connected Attach the contols to the oven s control panel In order for the controls to work correctly press in and then turn to free them from the safety catch If the cardans are too short it is possible to attach an elongation Code N PRM 00 0001 INSTALLER S MANUAL Pevised Date 2006 With respect to the CGC 4G Al AL hob Page N 38 of 95 Connecting the hob to the oven is carried out in the same way as before apart from step 7 which needs to be altered 7 Fit the oven trim as instructed in the accompanying manual Take care to fit the trim correctly 3 4 GAS CONNECTION We would like to remind you once more that connecting the hob to the gas supply should always be carried out in strict accordance with current installation regulations The appliance should be installed in a kitchen that is adequately ventilated as stipulated in the current installation regulations The hob should be connected to the gas supply via a metal tube This tube should be placed in order that it does not touch any moving part of the cabinet or other electrical appliances It should be situated in a place where it cannot be obstructed and where its entire length which should not exceed 2 metres may be inspected The hob is equipped with a Y diametre connection in compliance with the ISO 228 1 standard 10 12mm copper tubing is also supplied which should be soldered to the gas supply pipe E
6. ed at a distance of more than 10 cm a The hobs referred to in this installation manual are compatible with TEKA ovens In this case consult the corresponding manual before installing The installation process does not differ much from model to model Below are installation instructions for each model in the range with both independent and ME controls and for gas electric and mixed models 26 Code N PRM 00 0001 INSTALLER S MANUAL Pevsed Date 2006 3 1 INSTALLATION OF HOB Page N 27 of 95 E 60 2 AND ES 60 2 E 50 1 Minimum distance to wall 1 Minimum distance to wall 2 Minimum ventilation distance 2 Minimum ventilation distance Distancias minimas a paredes Distancias m nimas a paredes Distancias m nimas de ventilaci n Distancias m nimas de ventilaci n 40 mm minimo le 40 mm minimo Huecos de encastre Huecos de encastre 3 Space for recess 3 Space for recess 27 Code N PRM 00 0001 INSTALLER S MANUAL Pevsed Date 2006 SM AND CG EC AND CGC ECC Page N 28 of 95 1 Minimum distance to wall CG LUX 60 Distancias minimas a paredes Distancias minimas de ventilaci n CG LUX 70 Hueco de encastre 2 Minimum ventilation distance 3 Space for recess 28 R CKO 1 Minimum distance to wall 2 Minimum ventilation distance VITROCERAMIC HOBS 1 Minimum distance to wall Distancias minimas a paredes 100 i g
7. he shafts of the fixing plate Glass control panels Make an opening in the kitchen cabinet with the following measurements 527x 70 mm Screw in the two fixing plates so that the shaft can be inserted into the control panel To connect the hob to the control panel insert the hob connector into the back of the panel Attach the cardans Insert the panel introducing it from right to left into the shafts of the fixing plates Exterior measurements of the panel 560x85mm 40 Metallic control panels Code N PRM 00 0001 INSTALLER S MANUAL Pevised Date 2006 Page N 41 of 95 Make an opening in the kitchen cabinet with the following measurements 435 x 70 mm To make this opening draw the outline and the attachment holes with the paper stencil supplied with the panel Attach the plate with 4 screws so that the higher part is to the right Insert the panel from right to left within the the plate that has just been attached Check that the panel is in the correct place and finish attachment To connect the hob to the control panel insert the hob connector into the back of the panel Attach the cardans For all models a minimum opening of 50 cm is needed to ensure adequate ventilation 41 Code N PRM 00 0001 INSTALLER S MANUAL Pevsed Date 2006 Page N 42 of 95 Models IR IT 635 IR 735 and IR IT 645 feature new casings manufactured from synthetic glass fibre which a
8. llow for a reduction in the height of the hob improving their installation above other electrical appliances such as ovens dishwashers or even closed drawers 42
9. ode N PRM 00 0001 INSTALLER S MANUAL Pevised Date 2006 For models N s CG 1 4G CG 1 3G1P and Vitroceramics Page N 34 of 95 1 Self threading screw for kitchen cabinets with a thickness of 20 mm or 30 mm Place the attachment clips as shown in the illustration fig 12 Se SY 20430 mm If thickness is equal to 30mm use self threading screws M5 Tornitto autorroscante para muebles encimera de 20 y 30 mm de grosor For model N CGC Al AL Insert the push nuts into the screw housings See figure 13 Having attached the clip which corresponds to the thickness of the surface 20 30 or 40mm fully tighten all Screws Key A Leaktight seal B Work surface C Screw D Attachment clip E Push nut CGC 46 Al AL plate and Soft Series Step 2 After checking that the cabinet measurements are correct it is necessart to attach the leaktightness seale J under the hob Step 3 Place the clips K as shown in the illustration fig 15 attaching them to the gaps in the lower part of the housing with the 4 2mm thread screws The clips seal and screws are all supplied with the appliance ig 4 34 Code N PRM 00 0001 INSTALLER S MANUAL Pevised Date 2006 Page N 35 of 95 In the 600x510 series the procedure for fitting the plate is identical to other procedures This hob is designed to be recessed into worktop surfaces with a thickness of 20 30
10. or 40 mm Attach the leaktight seal J underneath the hob E gt a E Fix the four clips G using the two tabs P SS i A JA in the spaces O in the hob La 7 Next place the hob in the space and tighten Y the screws T of the 4 clips with the ical corresponding key Fig 5 For the EX 70 series the fitting process is as follows 1 Turn the hob and correctly position the adhesive side of the the seal E see fig around the edge 2 The ends of the seal should be joined together without overlapping 3 Place the hob in the space 4 Attach with the clips S carefully introducing the tab into the slot H on the bottom of the hob 5 Tighten screw F until it holds clip S to the cover see illustration 35 Code N PRM 00 0001 INSTALLER S MANUAL _Fevised Date 2006 Page N 36 of 95 TR 932 For all models with bevelled edges before installing the hob it is necessary to remove any o remains of material and check that the seal is AS correctly in place It is also important that silicone zo es is not used as there is a risk of breakage when dismantling When the hob is fitted into kitchen cabinets the installer needs to ensure that there is no contact between the bottom of the hob and the cabinet In order to guarantee this it is necessary to fit some protection which may only be removed with tools This protection should be placed at lea
11. st 20 mm from the bottom of the hob so that the mains electric supply cable does not come into contact with the hob The back of the lower cabinet needs to feature an opening in order that air may freely circulate The wood on the front of the cabinet shoud be removed to ensure an opening that will allow air to reach the inside of the space where the hob is located The distance between the hob and the cabinet should be large enough to ensure sufficient ventilation Carefully position the hob in the recess space and attach with the respective clips Tighten the screws until it is correctly fixed in place 36 Code N PRM 00 0001 INSTALLER S MANUAL _Fevises Date 2006 Page N 37 of 95 3 3 FIXING CARDANS IN CONTROL FREE HOBS TO OVEN TEKA Rear view of control panel 1 2 37 Disconnect the electrical supply Remove the telescopic attachments by pushing the small button marked PUSH A with the point of a screwdriver until it can be pulled out a few centimetres Remove the four fasters from the ends Partially insert the oven into the space in the instalation bearing in mind that the cardan on the hob should not be moved A space needs to be left in order to be able to insert the other end of the cardan into the back part of the control panel and then attaching the fasteners For electrical connection connect the hob to the oven Place the oven carefully into the recessed opening and ch
12. t J To a Distancias LESA de ventilaci n j min 650 mm min 40 mm Huecos de encastre E Mod VTN DC VT HDC2 Mod VTC DC VTC B VT DUAL 1 VTC HDC2 VS U VR 622 y VT CM 3 Space for recess Code N PRM 00 0001 INSTALLER S MANUAL _Fevisea Date 2006 Page N 29 of 95 2 Minimum ventilation distance Distancias m nimas a paredes Distancias m nimas de ventilaci n sm Hueco de encastre TR 620 12620 AND TR640 3 Space for recess Depending on the model in question the recessing system is designed for cabinets with a work surface thickness of 20 30 and 40 mm In the event that a separation board is not required the QKQ INSTALLER S MANUAL rocio aos Page N 30 of 95 induction models n s IR IT 635 IR IT 645 and IR 735 include a suplementary casing which shoud be fitted when installing the appliance under a drawer 30 Code N PRM 00 0001 INSTALLER S MANUAL _Fevised Date 2006 Plate N TR 932 Page N 31 of 95 1 Minimum distance between ajacent walls 2 Interior cut measurement 3 Exterior work surface measurement Minimum distance between adjacent walls Interior cut measurement Exterior cut measurement External measurement of worksurface Plates N s VI TC 60 21 AND VI TC 60 41 Fig 2 31 CKO IR 622 IZ 622 1T622 Code N PRM 00 0001 INSTALLER S MANUAL Pevisea Date 2006 Page N 32 of 95 1