1. we To other pa modules eur 4 eo Communication gt Grafica partial view bus To DigiplexNE control panel ES 2 5 MOUNTING GRAFICA 1 Place Grafica s back plate flush against the mounted metal wall plate 2 Slide the Grafica s open slots labeled D Figure 5 on page 7 onto the metal wall plate s tabs labeled B Figure 6 on page 7 3 Gently apply downward pressure to snap the Grafica onto the metal wall plate 4 You may insert an optional screw under Grafica keypad through the space in the metal wall plate s left tab Figure 6 on page 7 6 Reference amp Installation Manual Figure 5 Grafica Back Plate o o Clip Metal wall plate Optional scf w inserted here DigiplexNE Grafica Keypad Module 7 2 6 UNMOUNTING GRAFICA 1 If required remove the optional screw 2 Gently lift the unit upwards with your hands until it separates from the metal wall plate Figure 7 Figure 7 Unmounting the Grafica di N Metal wall plate 8 Reference amp Installation Manual 3 0 PROGRAMMING _ Enter the Module Programming Mode enter the desired section followed by the required data When programming the Grafica use the keypad s programming sheets in the DigiplexNE Modules Programming Guide Refer to Programming Sections i
2. 005 to 255 seconds Section 100 Download From Memory Key DOWNLOAD DATA FROM MEMORY KEY Section 110 Copy to Memory Key DOWNLOAD DATA TO MEMORY KEY DigiplexNE Grafica Keypad Module 19 Warranty The Seller warrants its products to be free from defects in materials and workmanship under normal use for a period of one year Except as specifically stated herein all express or implied warranties whatsoever statutory or otherwise including without limitation any implied warranty of merchantability and fitness for a particular purpose are expressly excluded Because Seller does not install or connect the products and because the products may be used in conjunction with products not manufactured by Seller Seller cannot guarantee the performance of the security system Seller obligation and liability under this warranty is expressly limited to repairing or replacing at Sellers option any product not meeting the specifications In no event shall the Seller be liable to the buyer or any other person for any loss or damages whether direct or indirect or consequential or incidental including without limitation any damages for lost profits stolen goods or claims by any other party caused by defective goods or otherwise arising from the improper incorrect or otherwise faulty installation or use of the merchandise sold 2002 Paradox Security Systems Ltd Grafica DigiplexNE Winload and NEwar
3. SECTION 003 OPTIONS 1 TO 4 Potential troubles have been sorted into groups With these options enabled the keypad will emit an intermittent beep tone whenever a trouble condition occurs from one of the Trouble Groups The intermittent beep will remain activated until the user enters the Trouble Display or if the trouble is resolved For a list of troubles see the DigiplexNE Reference and Installation Manual The intermittent beep will be re initialized whenever the trouble condition reoccurs By default options 1 to 4 are OFF 4 8 1 SYSTEM AND CLOCK TROUBLE BEEP SECTION 003 OPTION 1 Option 1 OFF Beep disabled Default Option 1 ON Beep on System Troubles and Clock Loss 4 8 2 COMMUNICATOR TROUBLE BEEP SECTION 003 OPTION 2 Option 2 OFF Beep disabled Default Option 2 ON Beep on Communicator Troubles 14 Reference amp Installation Manual 4 8 3 MODULE AND Bus TROUBLE BEEP SECTION 003 OPTION 3 Option 3 OFF Beep disabled Default Option 3 ON Beep on Module and Bus Troubles 4 8 4 ALL ZONE TROUBLE BEEP SECTION 003 OPTION 4 Option 4 OFF Beep disabled Default Option 4 ON Beep on all Zone Troubles 4 9 CONFIDENTIAL MODE TIMER SECTION 004 Section 004 determines the amount of time without action before the keypad enters Confidential Mode see page 12 The Confidential Mode Timer can be set from 005 seconds to 255 seconds Default 120 seconds 4
4. Grafica will go from Confidential Mode into Normal Mode once a key is pressed or a code is entered In normal mode Grafica displays the date time as well as the status of open zones for every partition that the keypad is assigned In addition Alarm Memory Display Bypassed zones and the Trouble Display can be displayed SECTION 002 OPTION 4 Option 4 OFF Normal Mode Default Option 4 ON Confidential Mode SECTION 002 OPTION 5 Option 5 OFF Exit confidential mode by entering an access code Default Option 5 ON Exit confidential mode by pressing a key The default option in Section 002 Option 5 default will ry only work if option 4 in section 002 is enabled 4 6 EXIT DELAY BEEP SECTION 002 OPTION 6 The keypad can beep once every second or play a selected song during the Exit Delay Timer During the final 10 seconds only the beep tone will be heard at a faster interval to provide a final warning before the area is armed Option 6 OFF Exit Delay beep disabled Option 6 ON Exit Delay beep enabled default 4 7 KEYPAD TAMPER SECTION 002 OPTION 8 When tamper is enabled and the keypad s anti tamper switch is triggered the keypad will send a Tamper report to the control panel DigiplexNE Grafica Keypad Module 13 via the communication bus Option 8 OFF Grafica s anti tamper switch is disabled Default Option 8 ON Grafica s tamper is enabled 4 8 BEEP ON TROUBLE
5. Option 1 ON Access Code digits will be displayed 4 3 DISPLAY EXIT DELAY SECTION 002 OPTION 2 Based on the user s needs an Exit Delay Timer can be programmed to provide the user time to exit the partition before the system is armed If this option is enabled the Exit Delay Timer s countdown will appear on the graphic LCD screen next to the hour glass icon Option 2 OFF Exit delay time will not appear Option 2 ON Exit delay time will appear Default DigiplexNE Grafica Keypad Module 11 4 4 DISPLAY ENTRY DELAY SECTION 002 OPTION 3 Based on the users needs an Entry Delay Timer can be programmed to provide the user time to enter their User Access Code before the alarm is triggered If this option is enabled the Entry Delay Timer s countdown will appear on the graphic LCD screen next to the hourglass icon Option 3 OFF Does not display Entry Delay Timer Option 3 ON Displays Entry Delay Timer Default 4 5 CONFIDENTIAL MODE SECTION 002 OPTIONS 4 AND 5 ry This option is not for UL Installations If the Confidential Mode is enabled and no actions are performed on the Grafica keypad for a period of time the graphic LCD will display the time date and all LEDs on the keypad will tum off until either a key is pressed or an access code is entered The period of time in which no action is performed is defined by the Confidential Mode Timer on page 15 12 Reference amp Installation Manual
6. 10 DOWNLOAD FROM THE MEMORY KEY SECTION 100 Use this section to download Grafica s section 001 to 004 all zone labels area labels and user labels from the Memory Key To download the contents 1 Insert the Memory Key onto the keypad s connector see Figure 8 on page 16 2 To download the contents of the Memory Key enter the keypad s programming mode and enter section 100 3 When the keypad emits a confirmation beep wait five seconds and remove the Memory Key after the second confirmation beep DigiplexNE Grafica Keypad Module 15 Figure 8 Memory Key Connector partial view 4 11 COPY TO MEMORY KEY SECTION 110 Use this section to copy Grafica sections 001 to 004 all zone labels area labels and user labels to the Memory Key To copy the contents 1 Insert the Memory Key onto the keypad s connector Ensure the write protect jumper is on figure 9 on page 17 2 To copy the contents to the Memory Key enter the keypad s programming mode and enter section 110 3 After the confirmation beep wait five seconds and remove the Memory Key after the second confirmation beep Remove the Memory Key s jumper if you do not wish to A accidently overwrite its contents 16 Reference amp Installation Manual Figure 9 PMC 3 Jumper Settings Jumper ON Jumper OFF Can copy and download Cannot override the contents contents ofthe memory key PMC 3 Only the PMC 3 Memory Key will function with
7. and zones alarm clock and on site upgradable firmware Grafica s design uses the latest and most sophisticated technologies available such as metallic colour finishing laser trimmed text flexible and multi layered PCBs and SMD fine pitch components With its shocking ultra modern style Grafica sets a new milestone for communication devices in the security industry for years to come 1 1 SPECIFICATIONS Power input Power indication Locate indication Bus fault indication Anti tamper switch Display Compatibility Typically 12 to 16 Vdc 130mA maximum Blue LED on Blue LED flashes Fault indication message will appear on screen Yes Film Super Twisted Nematic Black and white contrast 128 X 128 pixels Under ESD conditions the screen may go blank To reset the screen press any key DigiplexNE version 1 3 or higher Winload version 2 2 or higher NEware Version 2 0 1 2 NAVIGATION Grafica s three action keys represent selections that appear directly above the key on the screen They enable you to move forward back toggle the status of you to highlight and Action Keys Lei options and save choices The scroll keys enable select options throughout the various menus Figure 1 Key Overview Scroll Keys DigiplexNE Grafica Keypad Module 3 2 0 INSTALLATION 2 1 VIEWING ANGLE The Grafica keypad s graphic LCD is best viewed from a direct angle between a range of 20
8. Grafica Graphic LCD Keypad DNE K07 Reference and Installation Manual P_A R A OD o Xe SECURITY SYSTEMS TABLE OF CONTENTS INTRODUCTION Specifications Navigation wok INSTALLATION Viewing Angle Keypad Cover Clearance Mounting the Metal Wall Plate Connecting Grafica Mounting Grafica Unmounting Grafic vonna aP PROGRAMMING Entering Module Programming Mode Programming Methods SYSTEM OPTIONS Partition Assignment Display Code Entry Display Exit Delay Display Entry Dela Confidential Mode Exit Delay Beep Keypad Tamper Beep on Trouble Confidential Mode Timer Download from the Memory Key Copy to Memory Key PROGRAMMING SECTIONS 1 0 INTRODUCTION O o Grafica is the most advanced keypad and communication device in the security industry Developed to resolve operational flaws with security system keypads Grafica offers the ability to view zone locations on a floor plan drawing through its graphic LCD screen and provides simple menu driven commands that eliminate the need of user manuals thus reducing training time to a minimum The software contains over 120 000 lines of code and was developed in collaboration with end users resulting in a keypad that is intuitive and guides the user to the next logical step Other software related features include downloadable tunes and bitmaps for many functions a smart search engine for users
9. Grafica A keypads DigiplexNE Grafica Keypad Module 17 5 0 PROGRAMMING SECTIONS O O A Default Setting Section 001 Keypad Partition Assignment Option OFF ON n Partition 4 DISABLED A ENABLED 2 Partition 2 DISABLED A ENABLED 3 Partition 3 DISABLED A ENABLED 4 Partition 4 DISABLED A ENABLED 5 Partition 5 DISABLED A ENABLED 6 Partition 6 DISABLED A ENABLED I7 Partition 7 DISABLED A ENABLED 8 Partition 8 DISABLED A ENABLED A Default Setting Section 002 General Options 1 Option OFF ON 1 DispLay cone ENTRY A DISABLED ENABLED 2 Disptay Ex DeLay DISABLED A ENABLED 3 DispLav ENTRY DELAY DISABLED A ENABLED 4 ConFIDENTIAL MODE A DISABLED ENABLED 5 To EXIT CONFIDENTIAL MODE A ENTER CODE PRESS KEY 6 Exit Detay BEEP DISABLED A ENABLED 7 Future Use NIA NA 8 KevPao Tamper A DISABLED ENABLED Must be enabled through Option 4 in section 002 first 18 Reference amp Installation Manual A Default Setting Section 003 Beep on Trouble Option OFF ON 1 System amp CLock TROUBLE A DISABLED ENABLED BEEP 2 Communicator TROUBLE BEEP A DISABLED ENABLED 3 Mopute amp Bus TROUBLE BEEP A DISABLED ENABLED 4 ALL Zone TROUBLE BEEP A DISABLED ENABLED 5 FUTURE Use N A NIA 6 Future Use N A N A 7 Future Use N A NIA 8 Furure Use NA NIA 120 seconds Default Setting Section 004 Confidential Mode Timer Data
10. and 10 Figure 2 Be sure to install the Grafica keypad at a height and in a direction that provides the best viewing angle Figure 2 Viewing Angle 20 cn 2 2 KEYPAD COVER CLEARANCE Gre cas keypad cover Figure 3 Cover Clearance requires sufficient space in order to open properly Ensure a clearance of approx 3 5 9cm between the open keypad cover and possible obstructions such as a light switch Figure 3 Gem Bi Light switch 4 Reference amp Installation Manual 2 3 MOUNTING THE METAL WALL PLATE 1 Place metal wall plate to desired position 2 Drill and insert screws into holes labeled A as shown in Figure 3 Figure 3 Metal Wall Plate A Used also for electrical box A A B B A A Used also for electrical box 2 4 CONNECTING GRAFICA You can connect Grafica to the DigiplexNE control panel s communication bus in a star and or daisy chain configuration The communication bus consists of four wires that provide power and two way communication between the control panel and all modules connected to it Connect the four terminals labelled RED BLK GRN and YEL of the module to the corresponding terminals on the control panel as shown in Figure 4 on page 6 Please refer to the DigiplexNE Installation amp Reference Manual for maximum allowable installation distance from the control panel DigiplexNE Grafica Keypad Module 5 Figure 4 Connection Overview
11. e are trademarks of Paradox Security Systems 20 Reference amp Installation Manual PARADO Xy SECURITY SYSTEMS 780 boul Industriel S Eustache Montr al Qu bec Canada J7R 5V3 Fax 450 491 2313 www paradox ca Printed in Canada 08 2002 GRAFICA EI01 vad
12. n section 5 0 to keep track of which sections were programmed and how We strongly recommend you read this entire manual before you begin programming Grafica can also be programmed using the WinLoad Security System Management Software For more information refer to the WinLoad instructions or visit our Web site at www paradox ca Floor plans tunes and graphics can be downloaded to y Grafica using Winload V2 2 or higher and NEware V2 0 or higher 3 1 ENTERING MODULE PROGRAMMING MODE Like all other keypads in the system Grafica is programmed through the control panel To do so you must first enter the Module Programming Mode Step 1 From Normal Mode press and hold the 0 key Step 2 Enter the INSTALLER CODE by default 000000 Enter section 4003 Enter Grafica s 8 digit SERIAL NUMBER Enter the 3 digit SECTION you want to program Enter the required DATA The control panel will then redirect all programming to the selected Grafica keypad Use the scroll and action keys to navigate through desired sections DigiplexNE Grafica Keypad Module 9 section 0000 in Step 3 to view Grafica s version and serial ry The serial number is located on Grafica s PCB or enter number 3 2 PROGRAMMING METHODS The following methods can be used when programming the Grafica keypad 3 2 1 FEATURE SELECT PROGRAMMING You can program sections by enabling or disabling options Within these sections keys 1 to 8 or scroll keys re
13. present a specific Grafica option Use the scroll keys to highlight the desired option and press the corresponding action key to enable or disable the option An X will appear to indicate that the option is enabled Press the appropriate action key to save the status of selected option s 3 2 2 DECIMAL PROGRAMMING Some sections require the entry of a decimal value For this method any value from 000 to 255 can be entered 3 2 3 HEXADECIMAL PROGRAMMING Some sections require the entry of a hexadecimal values A to F Press the key to scroll through these values If the value is left unchanged for a second or two Grafica will automatically select it and move forward to the next digit 10 Reference amp Installation Manual 4 0 SYSTEM OPTIONS 1222 The following sections detail the options that can be programmed for Grafica 4 1 PARTITION ASSIGNMENT SECTION 001 OPTIONS 1 TO 8 Each keypad in the system can be assigned to one or more partitions In section 001 options 1 to 8 represent partitions 1 through 8 respectively To assign the keypad to a partition enable the option that corresponds to the desired partition By default partitions 1 to 8 are enabled 4 2 DISPLAY CODE ENTRY SECTION 002 OPTION 1 This option displays the digits of the User Access Codes on the graphic LCD as they are entered Option 1 OFF Digits are replaced by a Default