Home

Hurricane Haze 2D User Manual Rev. 10

image

Contents

1. Failure to comply with this information may render the product partially or completely inoperative cause damage to the product or cause harm to the user Important installation or configuration information Failure to comply with this information may prevent the product from functioning correctly Useful information DO amp Document The information and specifications contained in this document are subject to change without notice CHAUVET assumes no responsibility or liability for any errors or Information omissions that may appear in this manual Copyright 2014 CHAUVET All rights reserved Electronically published by CHAUVET in the United States of America Author Date Editor Date A Leon 04 18 14 L Henry 04 18 14 Hurricane Haze 2D User Manual Rev 10 Page 3 of 16 Productata Use on Dimmer X Auto Programs X Glance Outdoor Use X Sound Activated P DMX X Master Slave Duty Cycle X Safety Notes Please read the following Safety Notes carefully before working with the AN product The Notes include important safety information about installation usage and maintenance Always connect the product to a grounded circuit to avoid the risk of electrocution Always disconnect this product from the power source before cleaning it or replacing the fuse Make sure the power cord is not crimped or damaged Never disconnect the power cord by pulling or tugging on the cord Do not touch the output nozzle o
2. 5 Contact Us arta ad 15 6 Technical Specifications ccccceseceeeeeeeeeeseeeeseeeneeensesenseseeees 16 Hurricane M Haze 2D User Manual Rev 10 1 Before You Begin What Is HurricaneTM Haze 2D Included Power Cord Timer Remote 15 ft length Warranty Card Quick Reference Guide Unpacking Immediately upon receiving this product carefully unpack it and check the container in a which you received it Instructions Claims If the container or the material inside the container the product and included accessories appear damaged from shipping or show signs of mishandling upon receipt notify the carrier immediately not CHAUVET Failure to do so in a timely manner may invalidate your claim with the carrier In addition keep the container and all the packing material for inspection For other issues such as missing components or parts damage not related to shipping or concealed damage file a claim with CHAUVET within seven 7 days of receiving the merchandise Text Convention Meaning Conventions lt Menu gt A key to be pressed on the product s control panel 1 512 A range of values 50 60 A set of values of which only one can be chosen Settings A menu option not to be modified for example showing the operating mode current status Menu gt Settings A sequence of menu options to be followed ON A value to be entered or selected Icons Icon Meaning Critical installation configuration or operation information
3. DURATION and OUTPUT adjustment knobs to the desired positions INTERVAL knob sets the amount of time in between bursts of fog DURATION knob sets the length of time that the fog machine will run during the burst OUTPUT knob adjusts the fog output Press the lt CONTINUOUS gt latching button and the fog machine outputs fog until the button is pressed again The Manual Power LED Indicator above the button will light up during continuous operation Note The duration of continuous fog output is based on the capability of the fog machine Press the lt MANUAL gt button to momentarily output fog The fog machine will output fog for as long as you hold down the button During manual operation the Manual Momentary LED Indicator above the button will light up Note The duration of manual fog output is based on the capability of the fog machine Duration Adjustment Interval a Adiustment N Output Adjustment Timer LED INTERVAL DURATION Indicator Manual Birmai Momentary LED Manual rss Manual Control Momentary Button Timer On Off al Continuous Latching Button Latching Button Page 10 of 16 Hurricane Haze 2D User Manual Rev 10 Menu Map Mode Programming Steps Description DMX Mode o d 001 512 Selects the DMX starting address h001 h005 Low high Blower Speed f001 f005 Low high Manual Mode Configuration Set this product in DMX mode to control it with a DMX controller DMX Connect this product to a suita
4. TM HAZE 2D User Manual SHURRICANE Table of Contents Page 2 of 16 1 BeTOre TOU BEGIN ceras aii 3 Vinha tis Inclua cO ea pesa sl nad arar 3 Unpacking Instructions sesos ae 3 ANTS eared A 3 MOT GOV CONS escaso conoce Unai 3 ICONS sui A AD DD O O EE O O A O AR eet ere 3 DoOcCUmentIntormanON casar sao alas RT dC RD OD EAD DOER E SCE DOER RSna ad 3 Proqueral a Glance die ida dans 4 SAY NOIES ica 4 2 ANTOdUCUIO aonana 5 Product OVERVIEW sara unia a e da eel 5 Proa LU DIMENSIONS ti e a te le eet hl e 6 A O 7 AGAIN be ee GE 7 FUSE ReblaCeMeNl ic aoe eet a eee ee aa iai 7 MOUAUND sora 8 Sic SA O A a E ete 8 o a A DS ences eset oases acer E DS a DT ceeoee ce 8 Ao RAS OE AEE 9 Control Panel Operatiois rassin o a EDS 9 Flula Tank Indicator LEDS e do dd O do 9 Wired Timer Remote Operation cccccccoocccnncccconccnnccnnnnncnnonononnconononanncnnnnnnnos 10 PUCCIO da UV RESPONDE ionia 11 CONAN DA e ica 11 lg A RR ERR DR RE PR 11 Configuration Standalone Mode ccccccssseeceeeceeeeeeeeeeeeeeeeeeeeueeseeeeeaaeees 12 Wife iai DiS MOE NEED NR NOR EN EP PP 12 DMX Channel Assignments and Values ea 12 PAO q PASS PRENDE DRA A POTEET A PEE MED EN A DAR CN NRO E 12 5 Technical Information cuina aca taii 13 General Maintenance erre rrenan rena 13 LOL ACO uai Dan Oe RE DANO UA q RD EO A eT 13 General Troubleshooting sinners cdo tddi 14 alea Ua p e A E EEEE EE E E EE E E EAE E E EE E 1
5. Technical Support Address Av Santa Ana 30 Email servicio chauvet com mx Parque Industrial Lerma Lerma Mexico C P 52000 World Wide Web www chauvet com mx Voice 52 728 285 5000 Outside the U S United Kingdom Ireland or Mexico contact your dealer Follow their instructions to request support or to return a product Visit our website for contact details Hurricane Haze 2D User Manual Rev 10 Page 15 of 16 6 Technical Specifications Dimensions and Weight Power Operation Fog output 11 2 in 285 mm Length Power Supply Type Model specific Parameter Consumption Fuse size Power I O Connectors Cord plug Heat up Time 5 min Ft min m min 10 5 in 267 mm Height 13 7 in 350 mm Note Dimensions in inches rounded to the nearest decimal digit Range 120 V 60 Hz or 230 V 50 Hz 120 V 60 Hz 533 W 4 4 A F 7 250 V Input IEC Edison Tank Capacity 2 5 Weight 18 7 lb 8 5 kg Voltage Selection Fixed voltage 230 V 50 Hz 533 W 2 3 A F 5 250 V Fluid Consumption 8 2 ml min 1 200 34 Approved Fluids Chauvet Haze Fluid Gallon HFG Thermal Maximum External Temp Cooling System 104 F 40 C Convection DMX I O Connectors Connector Type Channel Range 3 pin XLR Sockets 2 Ordering Product Name Item Code ltem Number l 05070344 120 V HHAZE2D TM Hurricane Haze 2D 05070389 230 V 220VHHAZE2D RoHS TO 4S UL 499 CSA C22 2 No 64 P
6. age 16 of 16 Hurricane Haze 2D User Manual Rev 10
7. ble before the faulty unit Send product for repair Replace non DMX cables with true DMX cables Keep DMX cables away from AC wires or radio equipment Install an optically coupled DMX amplifier right before the product with intermittent problems Install an optically coupled DMX amplifier after unit 32 Install a terminator as indicated in the DMX Primer section If you still experience problems after trying the solutions presented here contact CHAUVET Technical Support Hurricane Haze 2D User Manual Rev 10 RETURNS CONTACT Us To return a product or request support In the U S contact CHAUVET World Headquarters see Contact Us In the UK or Ireland contact CHAUVE TO Europe Ltd see Contact Us In Mexico contact CHAUVET Mexico see Contact Us In any other country DO NOT contact CHAUVET Contact your distributor See www chauvetlighting com for distributors outside the U S United Kingdom Ireland or Mexico If you live outside the U S United Kingdom Ireland or Mexico contact your distributor of record and follow their instructions on how to return CHAUVET products to them Visit our website for contact details Call the corresponding CHAUVET Technical Support office and request a Return Merchandise Authorization RMA number before shipping the product Be prepared to provide the model number serial number and a brief description of the cause for the return You must send the merc
8. ble power outlet Turn this product on Connect a DMX cable from the DMX output of the DMX controller to the DMX input socket of this product Starting The Hurricane Haze 2D has one DMX personality a 2 channel mode for basic Address control The Hurricane Haze 2D uses up to two channels in its 2 channel DMX mode which defines the highest configurable address to 511 When selecting a starting DMX address always consider the number of DMX channels the selected DMX mode uses If you choose a starting address that is too high you could restrict the access to some of the product s channels If you are not familiar with the DMX protocol download the DMX Primer from www chauvetlighting com To select the starting address do the following 1 Press lt MENU gt repeatedly until d shows on the display 2 Use lt UP gt or lt DOWNS to select the starting address Hurricane Haze 2D User Manual Rev 10 Page 11 of 16 Configuration Set this product in one of the standalone modes to control it without a DMX controller Standalone 1 Connect this product to a suitable power outlet 2 Turn this product on Mode i Manual Mode Static Automatic or Sound to a DMX string connected to a DMX controller Products in standalone mode may transmit DMX signals that could interfere i Never connect a product that is operating in any standalone mode whether with the DMX signals from the controller To enable the Automatic Mode f
9. d above This will help to avoid any particles condensing inside the pump or heater Test run your Hurricane Haze 2D on a monthly basis to achieve the best performance Hurricane Haze 2D User Manual Rev 10 Page 13 of 16 General Troubleshooting Symptom Circuit breaker or fuse keeps blowing Product does not power up Product does not respond to DMX Intermittent DMX Problems Page 14 of 16 Possible Cause Excessive load on the circuit Short circuit along the power lines No energy on power outlet Loose or damaged power cord Blown fuse Internal problem Wrong starting address on the product Wrong DMX personality on the product Wrong polarity setting on the DMX controller Loose or damaged DMX cable Internal problem Signal cables are not DMX compatible Interference with AC or radio signals DMX cable too long Too many products connected Terminator not connected Possible Action Make sure that the total load does not exceed 80 of the breaker or fuse nominal current Check the power lines and power cords Check power outlet Change to another outlet Check the power cord Replace blown fuse with a good one of the same type and rating Send product for repair Set the correct starting address on the product Use the right fader s on the controller Set the correct DMX product s personality Assign the faders accordingly Change the signal polarity on the controller Check the DMX ca
10. gital display will take priority control If using the digital display and then connect the product to a DMX controller the DMX will take priority control The priority control levels are 1 DMX 2 Digital display 3 Remote controller Three indicator LEDs show the status of the fill tank as follows Red the fluid tank is currently heating Blue the fluid tank is ready Flashing Blue the fluid tank requires refilling Note The Hurricane Haze 2D may be operational while the fluid tank is heating Hurricane Haze 2D User Manual Rev 10 Page 9 of 16 Wired Timer Important Using the Control Board set the Fan and Haze output to 0 You can then Remote connect and operate the included wired remote with the Hurricane M Haze 2D Operation The wired timer controller allows you to automatically trigger fog output by setting interval and duration times LED indicator lights display the machine and controller s current state Rotary knobs set interval and duration times while manual and continuous buttons allow overriding control 1 Plug in the fog machine to power and turn the power switch to the product on Plug in the timer controller to the Manual Controller socket on the back of the fog machine Press the lt TIMER ON OFF gt latching button on the timer controller The Timer LED Indicator above the button will light up The lt TIMER ON OFF gt latching button will remain on until it is pressed again Set the INTERVAL
11. handise prepaid in its original box and with its original packing and accessories CHAUVET will not issue call tags Clearly label the package with the RMA number CHAUVET will refuse any product returned without an RMA number Write the RMA number on a properly affixed label DO NOT write the RMA number directly on the box Before sending the product clearly write the following information on a piece of paper and place it inside the box Your name Your address Your phone number RMA number A brief description of the problem Be sure to pack the product properly Any shipping damage resulting from inadequate packaging will be your responsibility FedEx packing or double boxing is recommended CHAUVET reserves the right to use its own discretion to repair or replace returned product s WORLD HEADQUARTERS CHAUVET General Information Technical Support Address 5200 NW 108th Avenue Voice 954 577 4455 Press 4 Sunrise FL 33351 Fax 954 756 8015 Voice 954 577 4455 Email tech chauvetlighting com Fax 954 929 5560 Toll free 800 762 1084 World Wide Web www chauvetlighting com UNITED KINGDOM AND IRELAND CHAUVETO Europe Ltd General Information Technical Support Address Unit 1C Email uktech chauvetlighting com Brookhill Road Industrial Estate Pinxton Nottingham UK World Wide Web www chauvetlighting co uk NG16 6NT Voice 44 0 1773 511115 Fax 44 0 1773 511110 MEXICO CHAUVET Mexico General Information
12. ly to a rigging point whether an elevated platform or a truss When rigging this product onto a truss you should use a mounting clamp of appropriate weight capacity The bracket has a 13 mm hole which is appropriate for this purpose When mounting this product overhead always use a safety cable Before deciding on a location for this product always make sure that it will be easy to access the unit for maintenance and programming purposes When power linking multiple products you must always consider the length of the power linking cable and mount the products close enough for the cable to reach them The bracket knobs allow for directional adjustment when aiming the product to the desired angle Only loosen or tighten the bracket knobs using your bare hands Using tools could damage the knobs M ounting Bracket Hurricane Haze 2D User Manual Rev 10 4 Operation Control Panel Operation 0 Fluid Tank Indicator LEDs To access the control panel functions use the three buttons located underneath the display Button Function CONTROL BOARD Press to scroll through the senda operating modes E E H lt UP gt Press to find a higher value OOO MENU UP DOWN lt DOWN gt Press to find a lower value Important note regarding the priority level for the three types of methods used to control the operation of your Hurricane Haze 2D If using the remote control and the digital display is touched the di
13. n this product It is very hot during operation and it may remain hot for several hours after turning the unit off If mounting this product overhead always secure it to a fastening device using a safety cable Do not mount this product on a flammable surface e g wood linoleum carton plastic or carpet Always make sure that the voltage of the outlet to which you are connecting the product is within the range stated on the decal or rear panel of the product Keep this User Manual for future consultation If you sell this product to another user be sure that they also receive this document This product is for indoor use only To prevent risk of fire or shock do not expose this product to rain or moisture Make sure there are no flammable materials close to the unit while operating Always install this product in a location with adequate ventilation at least 20 in 50 cm from adjacent surfaces Be sure that no ventilation slots on the unit s housing are blocked Make sure to replace the fuse with another of the same type and rating The maximum ambient temperature Ta is 104 F 40 C Do not operate this product at higher temperatures In the event of a serious operating problem stop using the unit immediately Never try to repair this product Repairs carried out by unskilled people can lead to damage or malfunction Please contact the nearest authorized technical assistance center Never connect this product
14. ollow the instructions below 1 Press lt MENU gt repeatedly until h shows on the display 2 Use lt UP gt or lt DOWNo gt to adjust the haze volume 3 Press lt MENU gt repeatedly until f shows on the display 4 Use lt UP gt or lt DOWN gt to adjust the blower speed DMX Channel Assignments and Values 2 CH Channel Function Value Setting 1 Blower speed 000 U 255 Low high 2 Haze volume 000 U 255 Low high Page 12 of 16 Hurricane Haze 2D User Manual Rev 10 5 Technical Information General Maintenance Do not allow the haze machine to become contaminated After every 40 hours of continuous operation use Chauvet Fog Cleaner Quart through the system to prevent the accumulation of particulate matter in the heating element is recommended The recommended cleaning regimen is as follows 1 Empty all haze liquid from the machine 2 Add cleaning solution to tank 3 Plug unit in and allow it to warm up 4 Run the unit in a well ventilated area until the tank is almost empty Do not allow the pump to run dry 5 Cleaning is now complete Refill with haze liquid Run the machine briefly to clear any cleaning solution from the pump and heater Hurricane Haze 2D Make sure you use FCQ regularly to increase the life of E Fog Cleaner Quart FCQ was specifically developed by Chauvet to clean your your product Storage Before storing this product FCQ through the system as described in the cleaning metho
15. rating indicates the product s average current draw under normal conditions Always connect this product to a protected circuit circuit breaker or fuse making sure that it has an appropriate electrical ground to avoid the risk of electrocution or fire Never connect this product to a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel serves only as a 0 to 100 switch o gt Fuse Replacement AN Disconnect this product from the power outlet before replacing the fuse 1 Wedge the tip of a flat head screwdriver into the slot of the fuse holder 2 Pry the fuse out of the housing 3 Remove the blown fuse from the holder and replace with a fuse of the exact same type and rating 4 Insert the fuse holder back in place and reconnect power Installed fuse held by plastic clip a Safety cap Spare fuse holder inside safety cap The product does not ship with a spare fuse however the safety cap has room for a spare Hurricane M Haze 2D User Manual Rev 10 Page 7 of 16 Mounting Orientation Rigging Mounting Diagram Page 8 of 16 The Hurricane Haze 2D may be mounted in any position provided there is adequate room for ventilation around it Be sure that the structure or surface onto which you are mounting this product can support its weight Please see the Technical Specifications section of this manual for weight information Make sure to mount the product secure
16. to a dimmer pack Make sure there are no flammable materials close to the unit while operating Depending on the amount of fog haze generated all fog machines may set off smoke detectors Do not use for space heating purposes FCQ Fog Cleaner Quart was specifically developed by Chauvet to clean your Hurricane Haze 2D Make sure you use FCQ regularly to increase the life of your product Page 4 of 16 Hurricane Haze 2D User Manual Rev 10 2 Introduction Product Overview Control Board SUTROL BOARD 200 LAMUYE MENU UP DONN Value Innovation Performance DMX In MENU MAP MENU VALUE DESCRIPTION ate door as12 DMXaddress DMX Out Wired Remote Power Switch DMX CHANNEL VALUES CHANNEL VALUE DESCRIPTION o 1 000255 Blower Speed lowchigh Fuseholder gt 1 0007255 Haze Volume low high Power In Rubber feet 4 Fluid amp wired remote storage access panel Hurricane Haze 2D User Manual Rev 10 Page 5 of 16 Product Dimensions DONOOOORROARNNOO Corra v CHAUVET Integration o UM e Page 6 of 16 Hurricane Haze 2D User Manual Rev 10 3 Setup AC Power This product can work with an input voltage of either 120 VAC 60 Hz or 230 VAC 50 Hz depending on the model To determine the power requirements for a particular product see the label affixed to the back plate of the product or refer to the product s specifications chart The listed current

Download Pdf Manuals

image

Related Search

Related Contents

Römer Kid  97050618(3)_S200-S220TR 2013.indd  Concurrent Abstract State Machines and +CAL Programs  See the Manual - Futureshop.co.uk  simplifica Manual Blackberry  Manual  字轟轟主『晶プタ一 取扱説明書 Machシu一ズ用  SNOW MASTER SNOW BUSTER SNOW KING  CT Service Manual - Copy Finishing Systems    

Copyright © All rights reserved.
Failed to retrieve file