1. x 26 8 2 MAGNETIC PROXIMITY SWITCH 26 Page 2 JVA Technologies Pty Ltd www jva fence com m O O 0 0 o o mmm o o u m Dnnnnnnnnnnnt NM o o og 10 10 10 10 10 1 1 PG CONTROL WEB SERVER KEYPAD CONTROLLING THE ZLM4 USING THE KEYPAD 1 KEYPAD VERSIONS 2 KEYPAD STATUS DISPLAY 3 ARMING DISARMING USING THE KEYPAD 4 WHEN AN ALARM OGCURS 5 TO SILENCE AN ALARM 6 TO CLEAR ALARM MEMORY 7 CHANGING THE PIN NUMBER 8 STANDBY BATTERY g INTERNAL BEEPER KEYPAD BEEPER 10 ZLM4 RELEVANT KEYPAD CODES INSTALLATION s s s s s n n a n n n ns ns na INSTALLATION STEPS FENCE TERMINALS CONTROL POWER AND IO TERMINALS WIRING DIAGRAMS lt lt s s s s ee 1 STANDALONE FENCE CONFIGURATIONS 2 LOW VOLTAGE ZONING SYSTEM 3 KEYPAD BUS WIRING 4 EXAMPLE GROUP WIRING DIAGRAM TECHNICAL INFORMATION e e o s s s eae LOD ERROR MESSAGES 2 PROGRAMMING OPTIONS 2 1 ENTER PROGRAMMING MODE 2 2 TO EXIT PROGRAMMING MODE 2 3 CHANGING THE INSTALLER PIN 2 4 CHANGING AN OPTION iD PROGRAMMABLE OPTIONS TABLE 3 PROGRAMMING OPTIONS IN DETAIL vi ZONE 1 FENCE VOLTAGE ALARM LEVEL O1xx 3 2 ZONE 2 FENCE VOLTAGE ALARM LEVEL O2xx JVA ZLM4 Manual 27 27 27 27 27 28 28 29 29 29 29 30 30 30 38 38 40 41 41 46 46 Page 3 1 T 2 a ZONE 3 FENGE VOLTAGE ALARM LEVEL D3xx 46 11 3 4 ZONE 4 FENCE VOLTAGE ALARM LEVEL D4xx 46 Va e MISSED PULSE COUNT O6xx a 8 m
2. User PINJIH Silence an alarm Single zone User PIN system only Start Programming the Z Series en Installer PIN 0 H ergiser Start Programming the Installer PIN 0 1 LN al N 2 gt CH S o pun e U Keypad Exit Programming any mode Change a User PIN User PIN O New PIN Change the Installer PIN 0 0 New Installer PIN Page 30 JVA Technologies Pty Ltd www jva fence com Arm All Zones Multi zone User PIN 1 0 groups Arm Zone 1 Master User PIN 1 1 Arm HV Zone x where x is User PINJ 1 x H any zone number up to 15 Disarm All Zones User PIN 2 O Disarm HV Zone 1 or Master User PIN 2 1 Disarm HV Zone x where x is User PIN 2 x any zone number up to 15 Note 1 Arm Gate circuits only User PIN 4 Keypad Audible Feedback 5 1 Toggle Keypad Chimes Toggle On 5 3 off Keypad Error Tones Toggle 5 4 On Off Keypad Alarm Tones Toggle 5 5 On Off Backlight Toggle On Off 8 Analyse Group 6 8 Reset and Display firmware User PIN 6 8 version number Reset and return to factory Installer PIN 6 8 defaults Siren test 6 3 Battery test 6 4 92 E JVA ZLM4 Manual O o 5 et 1 2l o lt S
3. N re Page 31 ke raj he Ke mn E 9 INSTALLATION It is recommended that all installations are performed by qualified techni cians 9 1 INSTALLATION STEPS 1 Read the entire ZLM4 and Energiser manuals first If an energiser is be ing used in conjunction with the ZLM4 read that entire manual as well 2 Design and build the fence Beyond the scope of this manual Ask your distributor for help if required 3 Decide where the energiser ZLM4 and Keypad are to be mounted If on an external wall it should be housed within a weatherproof equipment box shaded from direct sun 4 Remove the lid of the ZLM4 using a 5mm Hex key 5 Remove the ZLM4 PCB chassis from the housing by removing the two screws at the top corners 6 Mount the housing by using 4 screws through the rear of the box The box must be mounted to a wall in such a way that all of the 4 holes in the rear of the case are against the mounting surface 7 Replace the PCB chassis 8 If using a keypad remove the rear housing of the keypad and fix it to the wall 9 Wire the low voltage cables to the PCB terminals 10 Wire the fence zone cables to the PCB terminals 11 Set the Jumpers as required 12 Fit the battery leads to the battery The Error LED should be blinking twice to show mains fail 13 Replace the front cover lid 14 Turn AC power on 15 Arm the ZLM4 and Switch on the Energiser if used The LCD display will now show the
4. g Un D D L i A O lt 3 o el L i JVA ZLM4 Manual Page 69 12 8 5 Events Screen This screen allows you to view all the events that have been logged by the keypad over the set amount of days set in the keypad settings Luka mamar ed sa Event Log Date Time Source Description 1981 03 19 19 25 11 Z14 ID 3 Comms Failure Cleared 1981 03 19 19 25 11 ZM1 ID 1 Comms Failure Cleared 1981 03 19 19 25 06 ZM1 ID 1 Comms Failure Active 1981 03 19 19 25 06 Z14 ID 3 Comms Failure Active www jva fence com 1981 03 19 19 24 18 Z14 ID 3 Comms Failure Cleared 1981 03 19 19 24 18 ZM1 ID 1 Comms Failure Cleared 1981 03 19 19 23 15 ZM1 ID 1 Comms Failure Active 1981 03 19 19 23 14 Z14 ID 3 Comms Failure Active 1981 03 17 03 18 24 Installer Developer preferences 1981 03 17 03 17 57 Installer Zone names 1981 03 17 03 15 38 Installer Site preferences 1981 03 17 03 15 04 Installer Keypad preferences Val O gt Su x Val A Been o Ee N Page 70 JVA Technologies Pty Ltd www jva fence com 12 8 6 Zones and Zone Details Screen The zones screen left displays the zones that are currently in the site and by selecting one you can find further information about the zone in the zone details screen Right In the zone details screen you can set the cur rently selected zone to high or low power as well as the ability to disarm it Zones Name 7 Z14 ID 3 1 Feed Voltage Feed 4 0 kV Feed Curre
5. pad address This is best achieved by connecting one keypad at a time to the master Z Series device and updating the keypad address Once all keypads have a different address all can be connected to the system A recommendation is that one keypad is kept at address 1 The Z Series device now needs to be introduced to all of these keypads This is achieved by resetting the Z Series device using the keypad configured to address 1 by pressing User PIN 6 8 Alternately the power can also be removed to reset the Z Series device After a reset the Z Series device will determine what keypads are connected and only these addresses will be used in the future This prevents un authorised keypads being added to the system once it is running NOTE If the security system is to use Perimeter Patrol keypad address 2 should not be used by a keypad because that is the default keypad address that Perimeter Patrol uses Page 60 JVA Technologies Pty Ltd www jva fence com 12 6 KEYPAD CONFIGURATION NOTES Zone 1 the master must be connected to the group If it is not connected to the other Z Series devices in the group it will not send its data to the keypad Data such as voltages and alarm information which the keypad dis plays If Zone 1 is not connected the keypad will report a communications failure with all the zones A Slave Z Series device that is disconnected from the group will only talk to a keypad if it has a keypad address
6. Energisers with a negative voltage are not suitable The energiser output pulse energy must not exceed 18 Joules The maximum series resistance of the fence wire loop which can be accurately monitored is 5000 Ohms Not all versions of the PAE212 PAE224 or PAE218 GSM module recog nise the ZLM4 For compatibility please check with your distributor or JVA The JVA LCD keypad PTEO210 requires version 2 12 or later firmware to operate with a ZLM4 the keypad firmware can be viewed by at pow er up or by pressing 9 on the keypad Perimeter Patrol version 5 2 2 or later is required to operate with a ZLM4 JVA ZLM4 Manual O fe Lo ct 9 gt un Page 17 5 SPECIFICATIONS The specifications table below outlines the power consumption of the ZLM4 and the acceptable voltage and current ranges for different inputs and outputs Internal battery charger float 14 2Vdc voltage Internal battery charger 1200mA charging current Power consumption of ZLM4 130mA at 12 5 Vdc Note 1 Maximum AC input voltage when internal battery charger is supplying 580mA Battery backup time without 24 Hours keypad Maximum voltage on In1 SW2 and Gate inputs Note 2 Maximum power provided 35Watts 2 5A at 13 5V to Siren and Strobe outputs Note 3 Maximum Energiser Joules 18 Note 4 Maximum loop impedance 5000 Ohm Vi c ke rar gej U U O Q Ka Maximum
7. The default Battery Alarm Voltage is 10 0 Volts This alarm can be set to activate one of the relays and is part of the General alarm O D A gt A gt e ben 1 3 gt 3 5 7 11 3 7 Siren On Time 08x This option sets the duration of time that the siren will remain on after a fence alarm occurs After this time the siren will turn off for the Siren Off Time indicated in the table The siren will sound again if the alarm is still present after this off time has passed NOTE 18 The default is 3 Minutes This may be the subject of local regulations to stop an alarm causing undue disturbance to neighbours etc 19 The Siren On Time will be cut short if the battery falls below the low battery level 0 10 Seconds 1 30 Seconds JVA ZLM4 Manual Page 47 lt 2 z 2 Ki te is O ka 1 Minute i 4 Minutes 5 Minutes 7 Minutes 11 3 8 Siren Off Time 09x This option sets the amount of time the siren will be off for after the Siren On Time has expired If an alarm is still present after this off time the siren will sound again 10 Seconds itn 2 Minute 10 Minutes 30 Minutes 50 Minutes 11 3 9 Siren Cycles 10x This option sets the maximum number of times the siren will sound for the on time if the alarm continues This may be limited by local regulations to stop an alarm causing undue disturbance to neighbours
8. keys The keypad will beep twice to indicate that the command was accept ed If the PIN was incorrect the keypad will beep 3 times The LCD on the ZLM4 will now show the first programming option and its current setting lt 2 p z gt 2 Ki te je O Pressing the key will cycle through all the options on the LCD NOTE Not all numbers are used 11 2 2 To exit programming mode To exit programming mode press If left unattended the ZLM4 will time out and auto exit after approximately 5 minutes Page 42 JVA Technologies Pty Ltd www jva fence com 11 2 3 Changing the installer PIN The installer PIN may only be changed while in programming mode To enter a new installer pin press 00 followed by the new 6 digit PIN then the key If you cannot remember your installer or user PIN return the ZLM4 memory to default To do this remove power AC off and disconnect the battery open the ZLM4 enclosure remove jumper J4 and reconnect the battery for about 10 seconds Do not forget to re fit J4 This will return all options to the factory set defaults 11 2 4 Changing an Option The options have possible values in the range of 0 to 99 some are limited to lower maximum values To change an option value first check the option number see table below and then the table of values for that option On the Keypad press the op tion number followed by the required value For example to change option 1 to the
9. Alarm OR Tamper This will time out after the Siren Time Out time This function is latched Strobe As per Siren but does not time out will remain on until both channels are switched off This function is latched AC Fail Alarm on AC Fail Note Jumper J3 must be removed for this feature to be enabled D A gt A gt e 3 e gt Battery Alarm on low or bad battery 11 3 17 Group Mode 26x A group must have only 1 master The other Energisers Monitors in the group are slaves The correct procedure is Connect the keypad to each Energiser ZLM4 in turn programming each Option as required before linking the Keypad bus into a group The ZLM4 should only be a group master if there are no Z energisers in the group l e the group is made up of one or more ZLM4 s only If a PAE212 TCP IP adaptor is used it is the group master All other devices should be set to slaves All energisers must be synchronised therefore non synchronised agricultural energiser must never be used in a system with a ZLM4 This allows the ZLM4 pulses to be synchronised with other ZML4s or Z Series Energiser JVA ZLM4 Manual Page 53 0 DL Slave 1 Slave 2 Slave 4 Slave 6 Slave 9 Slave 10 Slave 12 Slave 14 2 3 6 8 9 E 2 rar G 2 E se je o Page 54 JVA Technologies Pty Ltd www jva fence com 12 Z SERIES KEYPADS There are 2 diffe
10. Screen this will only ap pear when there are active alarms 7 Settings screen button launches the Settings screen 8 Events screen button launches the Events screen 9 Zones screen button launches the Zone Details screen ho ta D D L i A O lt 3 o el L i 10 Site disarm button disarms the site privileges permitting 11 Site high power button puts the site into high power mode privileges permitting 12 Site low power button puts the site into low power mode privileges permitting 13 Panic Button Pressing this will send the panic command out activat ing the sirens 12 8 3 Alarm Screen This screen can be accessed by clicking the header bar where it currently states Ready to Arm Maintenance required in the image below when the keypad is in alarm or by clicking the dedicated alarms screen button From within the screen the alarms can be dismissed by clicking the Clear all button Note these will only clear latched alarms that have been resolved JVA ZLM4 Manual Page 65 N gt x lt Val A Been o th N ae Zones 214 ID 3 1 Feed 0 0 kV ZM1 ID 1 1 Feed 0 0 kV 12 8 4 Ready to Arm Maintenance required EEC Alarms Z14 ID 3 Maintenance Comms Failure Active Maintenance ZM1 ID 1 Comms Failure Active Clear all Settings Screen This screen allows the user to adjust preferences such as the screen br
11. Technologies Pty Ltd www jva fence com et o E A a e gt JVA ZLM4 Manual Page 13 3 FEATURES AND BENEFITS Australian designed and High reliability and great service manufactured Programmable options Customise the low voltage monitor to unique fence conditions Wall mountable robust Ease of installation and repair enclosure with easily detachable PCB chassis Inbuilt LCD voltage display and See fence conditions at a glance status lights Internal 7Ah 12V rechargeable Ensure continued operation of battery you security fence in the event of a mains power failure Optional LCD keypad Ease of control and Display of fence voltages Optional PC and internet Integration with Security connections Information Management systems Optional Touch keypad Touch keypad with fluid familiar user interface for even easier fence control mn A men v v faa ke m v pun v LL monitoring and programming of your security low voltage monitor Page 14 O JVA Technologies Pty Ltd www jva fence com Switched 12V outputs for Siren and Strobe Four Form C Relays with dry contacts or switched voltage Output Local audible and visual indication alerting user to breach of security Can be switched based on alarm triggers or input states Enclosed fence terminals JVA ZLM4 Manual Tamper resistant and prevents accident
12. a la M N l6Vac E SIREN STROBI DEALER JVA ZLM4 Manual Page 75 Electric Fencing Products WWW JVA FENCE COM The JVA logo Is a registered trademark of JVA Technologies Pty Ltd NA Technologies Pty Ltd
13. beep unless toggled off and auto scrolling will cease for about 3 minutes 12 3 6 Configuring the Keypad Enter Keypad Installer Pin 014 012345 01 Programming mode Exit Keypad Programming mode LCD Keypad Programming mode commands Default Code uses default In staller Pin You can change the messages and each of the zone labels e The Dealer Message displays when the system is on standby Page 58 JVA Technologies Pty Ltd www jva fence com e Zone Labels displays after the key is pressed during alarm memory or faults e The programmable Service Message is displayed during AC failure communication failure or low battery used 4 Cursor left 5 Next Message 6 Cursor right Fire not used 7 8 Character 9 Panic not used down Bd 0 Last Message Enter Exit Bypass not used Keys used for changing messages To activate the keypad programming mode enter the Installer PIN O 1 H Information may be entered into the keypad in the form of letters upper and lower case numbers 0 9 and 22 special symbols All characters are displayed in the order upper and lower case letters numbers and special symbols The Space character precedes the letter A To enter a Label use the 2 key to scroll through the characters until you reach the desired character If you scroll past the desired character the 8 key may be used to scroll backwards Note The space character is b
14. etc Oo 2 5 6 Note This is the maximum number of cycles for 1 continuous alarm inter mittent alarm events could cause more than this number of siren sound ings Page 48 JVA Technologies Pty Ltd www jva fence com The value is set directly For example to 2 siren cycles enter 1 0 2 The default is 3 minimum is 1 and the maximum is 9 11 3 10 Input Type 11x The control inputs can be inverted Unless an input is used for a Gate switch in which case it is always NC 0 NO Normally open 1 NC Normally Closed 11 3 11 Input 2 Function 12x This input cannot be configured to anything other than a Gate input at this time 11 3 12 Gate Delay 13x The gate switch must remain open for longer than the Gate Entry Exit De lay before the Gate Alarm is triggered If the switch closes within this time the Gate timer is reset to the Gate Entry Exit Delay value O Seconds immediate 30 Seconds 1 Minute 2 Minutes 3 Minutes 6 Minutes 7 Minutes 8 Minutes 0 3 5 7 11 3 13 Chime mode 14x This option allows the ZLM4 internal beeper and the keypad beeper to be JVA ZLM4 Manual D A gt si A gt e ben 1 3 gt Page 49 2 Ce ei fa 5 2 KC se de E used as a door chime for the gate switch When set to None the keypad beeper is used to indicate correct keypad operation only When se
15. inbuilt help the rest of this chapter refers to the simpler LCD keypads above 8 6 2 Keypad Status Display In normal operation the keypad shows a continuous summary of the sys tem status For example if the system is disarmed the keypad will display Ready to Arm If the system is armed then the keypad will display the voltages for each zone in the system Since there can be many things to display the keypad automatically scrolls through all relevant information Each screen is show for about 2 seconds If you wish to hold the display at a particular point simply press the key The auto scrolling will stop for about 20 seconds Pressing the key again will advance the display one step If a new trouble AC fail low battery etc or alarm occurs the keypad screen will jump to the relevant zone the keypad will beep unless toggled off and auto scrolling will cease for about 3 minutes 8 6 3 Arming Disarming Using the Keypad e Enter your PIN number four digits long and push the key Default is 1234 e Make sure the red ARM light comes on e The keypad will beep twice to confirm that the system is armed e The fence will power up and if all is well no faults the system will be ready to deter and detect e If there is a fault on the fence and it cannot achieve full voltage the LCD screen will indicate that there is a fault Page 28 JVA Technologies Pty Ltd www jva fence com e To disarm the system ente
16. is also used to set the programmable options For more on programming the device see 11 2 Programming Options on page 42 7 5 INTERNAL BEEPER KEYPAD BEEPER Depending on the chime setting the internal beeper and keypad beeper will sound when there is a fence alarm a gate alarm a door chime or a general alarm 7 6 ARM INPUT AND MAGNETIC KEY FOB The JVA Z Series energiser can be armed to energise the fence by closing a contact wired into the arm input Additionally you can arm and disarm the ZLM4 via a magnetic key fob by swiping it over the sensitive region Page 24 JVA Technologies Pty Ltd www jva fence com Pel GATE INPUT CONTROL INPUT 2 The gate input may be wired to a gate switch to trigger an alarm when a gate is opened for longer than the period set in the programmable options 7 8 GROUP SIMULTANEOUS PULSE FEATURE In some installations it may be preferable to provide the ability to link mul tiple units into a group When linked the individual Z Series energisers be come a Group As many as fifteen energisers can be grouped Individual units in a Group have simultaneous high voltage output pulses and act as if they are one energiser with multiple outputs This is designed so that no possible combination of individual outputs can be dangerous 7 9 STANDBY BATTERY Should there be a loss of mains power the Power Light on the keypad will go off and the status LED on the front panel will flash twice If the loss of
17. maximum press 0140 the keypad will beep twice to indicate that the command was successful The Ener giser LCD will immediately show the updated value As the keypad bus is common to a group of Z Series Energisers and ZLM4s one keypad could be used to program all connected units at the same time A Group containing Z Series Energisers and ZLM4 s MUST NOT get programmed this way as the ZLM4 contains different Option values to the Z Series Energisers Each ZLM4 Energiser will need to be isolated from the Group Wiring and programmed individually D A gt A gt e 3 e gt JVA ZLM4 Manual Page 43 lt 2 z gt te is Q 11 2 5 Programmable Options Table Voltage alarm level 20V zone 1 Sets the voltage below which the fence alarm will occur If the return voltage falls below this level for more than the Missed pulse count a fence alarm zone 1 will occur As above for zone 2 Voltage alarm level 20V zone 2 Voltage alarm level 20V zone 3 As above for zone 3 As above for zone 4 Voltage alarm level 20V zone 4 Not Used 0 Sets the number of pulses which may be missed before the alarm is activated Battery Alarm Voltage Missed Pulse Count 3 2 10V Siren On Time 4 3 Mins Sets the battery voltage threshold below which the general alarm will activate Sets the time that the siren and keypad beeper will stay on afte
18. power is prolonged the battery may discharge power and become inef fective The Power Light will start to flash indicating a battery low power problem If the battery is fully depleted the unit will not pulse If the stand by battery requires replacement the Power Light will flash and the Status Light will flash three times J M N O O 5 JVA ZLM4 Manual Page 25 LN l N 2 A CH S ce Bn O U 8 CONTROLLING YOUR ZLM4 e Your JVA ZLM4 security low voltage monitor has been designed for ease of operation The ZLM4 may be armed and disarmed using any of the following JVA permanent magnet key ring fob Key switch or remote switch connected to the control input IN1 e Remote control radio receiver connected to IN1 e Z Series Keypad LCD or Touch e JVA Webserver not all versions e JVA GSM module not all versions e Windows PC running JVA Perimeter Patrol e Low level interface wired to control inputs and relay outputs from a third part security alarm panel or Physical Security Information System PSIM Note More than 1 method may be used in the one installation 8 1 CONTROL ARBITRATION If an installation contains two ways to control the ZLM4 then the most re cent control signal will determine the Armed Disarmed state For example if the ZLM4 is armed via the keypad and then disarmed at the control input IN1 it will disarm The higher level control methods such as
19. sirens unless it is critical such that you might enjoy a restful nights sleep e Optional Quick access panic button e The ability to monitor and log all user actions e Can be used to maintain a log on a Perimeter Patrol managed system Page 56 JVA Technologies Pty Ltd www jva fence com in case the PC goes down or the TCP IP connection from the PAE212 to the PC is lost Note for all information to be captured each sub group will require PTEO230 Touch Keypad 12 3 LCD KEYPAD OPERATION 12 3 1 Wiring up your Z Series LCD Keypad Adiagram that shows how to wire up a Z Series LCD keypad can be found in 13 2 Appendix B on page 75 Remove the rear of the LCD keypad to expose the wiring terminals shown in the diagram above 12 3 2 Keypad status LEDs The LCD keypad has two LEDs Power and Arm which act as follows e Power On with Mains power flashes on low battery Arm On When the energiser is armed pulsing flashes when in Low Power Mode 12 3 3 Arming Disarming Using the Keypad Arm User PIN 1234 Disarm User PIN 12344 LCD Keypad arm disarm codes Default code uses the default User pin Enter your User PIN and push the key Make sure the red ARM light comes on and the keypad beeps twice to confirm that the system is armed The fence will power up and if all is well no faults the system will be ready to deter and detect To disarm the system enter your User PIN and press Note If there i
20. the Keypad on page 27 8 6 CONTROLLING THE ZLM4 USING THE KEYPAD The low voltage monitor can be installed in a convenient location close to the fence while the keypad can be positioned in an easily accessible place The systems status information e g mains power energiser on off fence voltages fence alarm auxiliary alarm etc are displayed on the keypad If a keypad is connected magnetic key fob and control input terminal may not be operational as they may have been disconnected by the installer 8 6 1 Keypad Versions The current version keypad is a PTE0210 with code version 2 00 Older ver sions have limitations The keypad version can be seen by pressing 9 PTEO200 Shows ALPHA KEYPAD Revision 7 0 e Cannot show Zone fence voltages e Shows only Zone alarms 1 8 e Does not show Gate alarms PTEO210 Shows PTEO210 and the code version e Can show fence voltages Will respond to 68H to analyse the group JVA ZLM4 Manual O o et 1 2 vo lt S N re Page 27 LN al N 2 A CH S o pun e U e Version 1 21 and below e Older version can be upgraded to V2 00 firmware e Cannot detect or operate with the ZLM4 e Version 2 20 and higher e ZLM4 is supported zones are displayed PTEO230 Touch screen keypad e Provides the most advanced monitoring and control of all Z Series de vices e All functions are available e Refer to the
21. zone voltages 16 Find and remove any faults on the fence 17 Test that a short in any zone puts the ZLM4 into alarm and shows the Page 32 JVA Technologies Pty Ltd www jva fence com correct Zone 9 2 Jumper Configuration The ZLM4 is equipped with three jumpers two of which J3 and J4 operate in an identical fashion to those on the Z14 The third jumper J8 will sup press the beeper on the ZLM4 when fitted These are located in the top left corner of the PCB Inhibit Mains fail J3 is fitted to inhibit error Mains fail errors if the intention is to operate 5 L the energiser on DC y only as in solar power A systems e gt J4 Factory default If the energiser jumper needs to be defaulted to factory settings remove all power AC and battery and remove the J4 jumper Reapply the mains and the battery power Reapply the J4 jumper and the Energiser will be reset to default settings JVA ZLM4 Manual Page 33 Inhibit internal Fitted to inhibit the beeper internal beeper irrespective of any option setting 9 3 FENCE TERMINALS R46 C31 E q e sl GA 14 ki i a motas E Kn N uz Po ne KT ON TPT48S 5 amp w Val E Description of fence terminals Left to Right Connect to zone 1 fence wires Loop 2 Connect to zone 2 fence wires Loop 3 Connect to zone 3 fence wires Loop 4 Connect to zone 4 fence wires Ground Connect to main fence eart
22. ETTINGS SCREEN De des ees o SP OK a je 66 12 8 5 EVENTS SCREEN Pe tee aoa Lee S y O ONE Sg ER 70 Page 4 JVA Technologies Pty Ltd www jva fence com 12 8 6 12 8 7 13 13 1 13 2 ZONES AND ZONE DETAILS SCREEN 71 PROGRAM DEVICES SCREEN 72 APPENDICES ee oos s sn n n n n n 074 APPENDIXA t t ow a toe 74 APPENDIX B x erg e oe s p a S woe r ce HS JVA ZLM4 Manual O ce gt D gt un Page 5 v ke gt dal Bn gej UN Be o i o 1 QUICK START GUIDE This quick start guide contains the bare minimum information to get your ZLM4 up and running with useful links to the more in depth information contained in this document 1 1 DEFAULT INPUT OUTPUT CONFIGURATION Figure 1 below shows the inputs and outputs for the ZLM4 low voltage monitor fa Fl Fk NH A Aa ad a al wa en SCH SIREN STROBE L ier 1 2 3 4 5 6 Default Input Output Configuration 1 2 DEFAULT CONFIGURATION 1 IN1 is configured to arm or disarm the energiser 2 This is configured as a gate input used for raising an alarm if the gate is left open for a minute while armed 3 This is where you attach the LCD keypad to program the energiser if the defaults are not the desired values or if you want to control the unit Page 6 JVA Technologies Pty Ltd www jva fence com from a different location 4 This output is config
23. Electric Fencing Products JA ZLM4 User MANUAL The JVA logo is a registered trademark of JVA Technologies Pty Ltd JVA Technologies Pru Ltd CONTENTS 1 Quick START GUIDE 2 ee s s s a s ee tt ts O Misal DEFAULT INPUT OUTPUT CONFIGURATION 6 1 2 DEFAULT CONFIGURATION e JE 1 3 WIRING UP YOUR ZLM4 x e 1 4 JUMPERS 8 1 5 FREQUENTLY USED LCD KEYPAD COMMANDS 9 2 INTRODUCTION a s s s s n n n n sns asas ee TO FEATURES AND BENEFITS eee s s eens 14 3 1 MORE FEATURES By yey Q Sis bee Rl UE a Gh Me Wes NA LE E A 16 4 CONSTRAINTS ee eee ee ee ee ee 17 5 SPECIFICATIONS ee ee eee eee eee es 18 6 EQUIPMENT REQUIREMENTS OPTIONS 20 6 1 REQUIREMENTS s ee s aa 20 6 2 OPTIONS X XZ a X 464 foo Gow Min dow 20 7 DESCRIPTION eee een ene enn enn eae 21 Tal FRONT PANEL STATUS LIGHTS 21 no Z 2 STATUS LIGHT CODES 22 Z DES FRONT PANEL LCD DISPLAY E E E 23 e 7 3 1 DISARMED 28 e 7 3 2 ARMED 2 x X 4 Je Bob S oe we oa be x BS U 7 3 3 ALARMS L L L L L L L 24 7 4 KEYPAD OPTIONAL a s x 24 725 INTERNAL BEEPER KEYPAD BEEPER Ga ME eh Nat QY ee 24 7 6 ARM INPUT AND MAGNETIC KEY FOB 24 y A GATE INPUT CONTROL INPUT 2 we 25 7 8 GROUP SIMULTANEOUS PULSE FEATURE Wi m ob 3 25 739 STANDBY BATTERY A Sade S tate E as u a 25 8 CONTROLLING YOUR ZLM4 26 8 1 CONTROL ARBITRATION
24. JEUIJOJU PUYOL Page 45 lt 2 Ce z gt 2 Ki te is E 11 3 PROGRAMMING OPTIONS IN DETAIL 11 3 1 Zone 1 Fence Voltage Alarm Level 01xx Sets the voltage below which the zone alarm will occur If the fence voltage measured at the return R loop terminal falls below this level for more than the Missed pulse count a fence alarm zone 1 will occur The value is set directly not via a table For example to set a threshold of 25V enter 0125 Setting this option to 0 effectively turns off fence voltage monitoring Warning Setting this level to higher than the normal running voltage of the fence will result in continuous fence alarms 11 3 2 Zone 2 Fence Voltage Alarm Level 02xx As above for zone 1 11 3 3 Zone 3 Fence Voltage Alarm Level 03xx As above for zone 1 11 3 4 Zone 4 Fence Voltage Alarm Level 04xx As above for zone 1 11 3 5 Missed Pulse Count 06xx This option enables the pulse count to be varied from the default 3 This is the number of bad or missing pulses that are counted before the alarm occurs NOTE The lower this option is set the more likely you are to get false alarms Page 46 JVA Technologies Pty Ltd www jva fence com The value is set directly For example to set a threshold of 2 bad or missing pulses enter 0 6 0 2 11 3 6 Battery Alarm Voltage 07x This option sets the battery voltage threshold below which the general alarm will activate
25. VA ZLM4 Manual Page 39 10 2 LOW VOLTAGE ZONING SYSTEM A ZLM4 can be combined with a JVA Z Series energisers which provides the main deterrence The ZLM4 provides fence monitoring by splitting the earth wires into four distinct zones Below Shows only how Loop 1 might be configured for the first zone of an electric fence This would have to be repeated for the following three zones In this configuration the ZLM4 must be configured as a slave and the Z Series energiser as the master As noted previously under 4 Constraints on page 17 the Z Series ener giser must not exceed 18 Joules The amount of Z Series devices that can be connected together in a group is limited by the ID numbers when using the keypad bus This limitation is removed if using TCP IP Security Energiser ZLM4 EEE AMAA o al le olf le off lo ol le ea ee 22 R F loop2 Loop3 Loop 4 Gnd To other low voltage fence zones N S O S m m d Page 40 JVA Technologies Pty Ltd www jva fence com 10 3 KEYPAD BUS WIRING See 13 1 Appendix A on page 74 for the diagram e Set the Group ID of the Z18 to Master 2601 e Set the Group ID of the ZLM4 to Slave 1 2602 The Group ID of the ZLM4 must be 1 value higher than the Group ID of the Z Series Energiser driving it A ZLMA4 by itself does not require the Group ID to be configured as it is fac tory set to Stand Alone mode 10 4 EXAMPLE GROUP WIRING DIAGRAM Z28
26. al contact with the low voltage terminals D y et lt MD L y UY OD D y et un Page 15 3 1 MORE FEATURES e Monitors for continuity using safe 50V DC pulses e Can be used to split a single security electric fence zone into up to 4 low voltage zones e Built in charger and space for a 12V 7 2aH backup battery e Alarms for fence short Low Voltage wire connected to ground Open circuit if the low voltage wire has been cut cross couple if two low voltage sectors are touching and High voltage short if the low voltage wire is touching a High voltage wire e Internal Beeper e AC fail Low Battery and Bad Battery Detection e Large number of keypad programmable options e Two Control Inputs can be configurable as NO Normally Open or NC Normally Closed contacts e Able to be integrated into third party access control and security infor mation management systems at a variety of levels e Enables the construction of systems from economical Key switch op eration to complex PC controlled applications e Runs from 16Vac or 12V DC external source e Fence connections are fully isolated from power and IO as per relevant parts of ICE60335 2 76 Vi E v v faa ge Val v ha v LL Page 16 O JVA Technologies Pty Ltd www jva fence com 4 CONSTRAINTS Any energiser used with the ZLM4 must comply with 1EC60335 2 76 electrical safety standard
27. and two ZLM4 connected to Perimeter Patrol through a PAE223 USB Interface gt le Q y Q ie 3 L To low voltage To high voltage To low voltage To Earth interleaved wires fence wires interleaved wires stakes e Set the Group ID of the Z28 to Master 2601 e Set the Group ID of the first ZLM4 to Slave 2 2603 Set the Group ID of the first ZLM4 to Slave 3 2604 JVA ZLM4 Manual Page 41 11 TECHNICAL INFORMATION 11 1 LCD ERROR MESSAGES The ZLM4 has the ability to display error messages At start up if any of the Power On Self Tests POST fail an error message will be displayed after the version number If these are non fatal the ZLM4 will continue through start up and be ready to run After any fatal error the LCD will now show a number which will aid in fault finding Fatal errors These will stop the unit Er 11 Memory CRC error Er 16 Slave Energiser cannot see the Master Energiser via Keypad Bus Er 17 Isolated processor not responding Self test errors Use keypad sequence 2 to show 11 2 PROGRAMMING OPTIONS Like the Z Series of security energisers the ZLM4 has non volatile memory in which programming options or setup parameters can be stored These are factory pre set defaults but can be field programmed using a keypad NOTE The default installer PIN is 012345 11 2 1 Enter Programming Mode To enter programming mode enter the 6 digit installer PIN followed by 0
28. d zones for improved targeting of the response to potential security breaches The ZLM4 is compatible with the JVA Z Series energisers It may be connected via a Keypad bus network with other Z Series devices to enable the whole group to be controlled via one keypad or linked to a PC running Perimeter Patrol The ZLM4 monitors a low voltage loop using intrinsically safe isolated ELV DC It employs a continuity check for detecting open circuits DC voltage level sensing to detect a short to ground and pulse voltage sensing to de tect a short to a line powered by a high voltage fence energiser The ad Page 10 JVA Technologies Pty Ltd www jva fence com vanced features of this device allow the performance to be tuned to the fence and to the particular requirements of the site This is done by ad justing the devices programmable options The ZLM4 will report an alarm on seeing a low voltage loop cut open circuit shorted to ground short when high voltage from an electric fence energiser wire is shorted to the monitored low voltage loop or when two low voltage loops short to one another cross couple Designed and manufactured to meet the most stringent international safe ty standards the JVA ZLM4 is in a class of its own when it comes to fea tures and benefits at an affordable price JVA ZLM4 Manual ot 2 c A i Page 11 Ke LRG esas re S 5 U gej o E Page 12 JVA
29. e tec ie a ZO 11 3 6 BATTERY ALARM VOLTAGE O7x vw moje eo de e Ch 7 11 3 7 SIREN ON TIME O8x 47 11 3 8 SIREN OFF TIME D9X 48 11 3 9 SIREN CYCLES 10x 48 11 3 10 INPUT TYPE 11x 2 2 49 11 3 11 INPUT 2 FUNCTION 12x4 49 11 3 12 Gate DELAY 13x 49 11 3 13 CHIME MODE 14x 49 11 3 14 BINARY OPTIONS 16x 50D 11 3 15 AUTO RE ARM TIME 20x 51 11 3 16 RELAY FUNCTIONS a a a s a s s s s s s s s o 51 11 3 17 GROUP MODE 26x 53 12 Z SERIES KEYPADS 000 eee eee ees 55 12 1 PTED210 LED KEYPAD 55 12 2 PTED230 TOUCH KEYPAD 56 12 3 LCD KEYPAD OPERATION 57 12 3 1 WIRING UP YOUR Z SERIES LGD KEYPAD 57 N 12 3 2 KEYPAD STATUS LEDS lt 57 e 12 8 3 ARMING DISARMING USING THE KEYPAD Pe i Cw Ve 57 g 12 3 4 MENUS B7 3 12 3 5 KEYPAD STATUS DISPLAY 58 U 12 3 6 CONFIGURING THE KEYPAD 58 12 4 TO EXIT KEYPAD PROGRAMMING aa a 60 12 5 CONNECTING MULTIPLE KEYPADS me Ga je Sh ee ee Cte 60 12 6 KEYPAD CONFIGURATION NOTES 61 12 7 SUMMARY OF KEYPAD FUNCTIONS 62 12 8 TOUGH KEYPAD OPERATION 64 12 8 1 SCREENS 64 12 8 2 HOME SCREEN 4 ww 64 12 8 3 ALARM SCREEN a a s s s 65 12 8 4 S
30. efore the A character When A is displayed press 8 to get a space When the desired character is displayed press the 6 key to move the cur sor to the next character position The 4 key moves the cursor to the left NOTE 22 If you move to the next message using 5 instead of the key you will lose any changes you made 23 To change the keypad address scroll through the messages until the keypad displays Keypad address __ then change the value by press ing 2 up or 8 down Submit the change by pressing The message order is e SERVICE MESSAGE Displayed under System Trouble JVA ZLM4 Manual Un D UM A O lt 3 o el L i Page 59 N Q gt x Val A Been o Si N e DEALER MESSAGE Displayed under the standby message Ready to Arm e ZONE NAMES e BAUD RATE should be left at 2400 e KEYPAD ADDRESS should be left at 1 12 4 TO EXIT KEYPAD PROGRAMMING When you have finished programming press NOTE The keypad will also exit the programming mode if you do not press any key within a five minute period To return the Keypad to default settings press the emergency button during power up CONNECTING MULTIPLE KEYPADS Re analyse the group User Pin 68H 1234 68H Up to three keypads may be used to remotely monitor and control Z Series devices To operate correctly each keypad must be configured to use a unigue key
31. en and strobe light e LCD Keypad PTEO210 Note 1 2 e Windows PC e Windows XP or later e PAE223 or PAE100 serial adaptor AND USB to serial adaptor or PAE212 TCP IP adaptor e Perimeter Patrol PC application Notes 1 While the Keypad is not essential for normal operation it is required to adjust the programmable options 2 Up to 3 Keypads may be connected in parallel on a ZLM4 each Keypad must have a unigue keypad address For more information please see www jva fence com au Page 20 JVA Technologies Pty Ltd www jva fence com 7 DESCRIPTION JVA 2LM4 ARMED POWER 9 ARMED rence sate status J M L O O 5 LAM ENERGISER CONTROL AND MONITOR UNIT 7 1 FRONT PANEL STATUS LIGHTS The status LED s on the front of the ZLM4 allow the user to quickly ascer tain the current status of the unit and if any action needs to be taken Be low is a brief description of each LED top to bottom and the information it conveys JVA ZLM4 Manual Page 21 Power On whenever the unit has e za Red when there is a fence alarm Gate On when there is a gate alarm Status Then number of times the status Light flashes indicates the status of the energiser See the table under Status Light Codes below 7 2 STATUS LIGHT CODES EE E Mains supply fail Restore mains power Low battery bad Charge or replace battery battery PCB service fault Return to repair service cent
32. et automatically Screen Dims This option sets the idle time required before the screen dims Sound Keyclick volume slider that adjusts the click volume that plays when a button is pressed Siren volume slider that adjusts the siren volume that plays when an alarm is detected Siren mutes option that allows you to adjust how long the siren will play for before being disabled System Set date and time This option sets the systems date and time Wi Fi settings This option launches the Wi Fi Settings such that the tablet can connect to a local Wi Fi network Email These settings allow the tablet to be configured to email up to two email addresses when a fence alarm occurs This can be configured such that only certain alarms will cause an email to be sent Keypad Automatically logout setting for the amount of time that needs to expire before automatic logout User Pin This setting allows you to change the pin reguired for logging on as a user Delete events this option adjusts how many days worth of events are stored and displayed in the events screen If a Micro SD card has been inserted the device will backup all events to this but will only display the amount of days worth of events selected here Show all events This option toggles whether or not the event log shows all system events or just the important ones Page 68 JVA Technologies Pty Ltd www jva fence com Quiet H
33. h stakes Page 34 JVA Technologies Pty Ltd www jva fence com 9 4 CONTROL POWER AND IO TERMINALS R4i R335 R44 R420 R40 RiS2 Bei REJO EEN pe S E ex prs be Prys 5 wapsi v Ws vu Wi AA S Meet BORAS D30 Q 031 D32 017 026 Gaam D27 0220190023 NO C NC NO C NC NO C Ic RELAY 3 RELAY 4 RELAY 5 RELAY 6 CS R230 Lo 2 y fe gt z Tama INI GATE SIREN STROBE 16Vac E JVA ZLM4 Manual Page 35 Energiser control input dry contact Defaults to normally open Can be used for a remote switch or a radio receiver The receiver may be powered from the keypad 12V terminal Energiser control input defaults to normally open low power but may also be assigned to gate input When the unit is armed and the gate is opened it will trigger the gate alarm Supplies power and data line for an external keypad The 12V source on these terminals is protected with 1A self resetting fuse Switched 12 volt output Low side switched 35W max including strobe A buffer relay should be used when connecting these outputs to an alarm panel Switched 12 volt output Low side switched ke rar amp Val E 35W max including siren A buffer relay should be used when connecting these outputs to an alarm panel AC IN 3 Way 16Vac power input Fused via F3 3A self resetting fuse The Earth terminal may be required to be connected to mains earth in some countr
34. ies consult your local wiring guidelines Page 36 JVA Technologies Pty Ltd www jva fence com Defaults to zone 1 alarm Relay 4 3 Way May be set to any of 16 alarm conditions Defaults to zone 2 alarm May be set to any of 16 alarm conditions Defaults to zone 3 alarm Relay 6 3 Way May be set to any of 16 alarm conditions Defaults to zone 4 alarm UOnejjeJSU JVA ZLM4 Manual Page 37 10 WIRING DIAGRAMS 10 1 STANDALONE FENCE CONFIGURATIONS The ZLM4 may be used to monitor a loop of wire on or under a perimeter fence e Bare conductors on insulators as per high voltage electric fence but powered by the ZLM4 low voltage monitor for sensitive environments such as public areas m je KH 14140 W A ITI Lid 40000000 tT AA th ra 4154011915 e Insulated wire woven through balustrade or chainmesh fencing The alarm is given if the insulated wire is cut or shorted to earthed metal ke N z S O 2 m m d Page 38 JVA Technologies Pty Ltd www jva fence com e Insulated wire buried underground The alarm is given if the insulated wire is cut or shorted to earth NOTE This is a suggested configuration only and has yet to be tested le Q Kel o Z L i J
35. ight ness zone names and other application preferences a CE Settings Display Screen brightness and dimming settings Sound Keyclick and siren volume settings System Date time and wifi settings Email Settings Events ZN Ch Arm High Power Arm Low Power Send email on alarms JVA Technologies Pty Ltd www jva fence com a LOG IN Email Send email on alarms 5 Keypad User and event log Settings Events settings 6 lt Site TN ua Site setup 7 Zones Arm Arm Custom zone names High Power Low Power N I a Developer settings m Debug options M L T Ke y lt 1 Display Contains brightness settings S e Q 2 Sound keyclick and alarm volume settings Lo 3 System date and time and Wi Fi settings 4 Email for configuring email notifications for alarms 5 Keypad change user pin automatic logout time and event log set tings 6 Site home screen customisation and site configuration settings in staller only 7 Zones allows zones to be renamed to be more memorable installer only 8 Developer settings this contains diagnostic information installer only JVA ZLM4 Manual Page 67 N O G gt v Val A Been o ka N Display Manual Brightness if checked will enable the Brightness slider allow ing you to select the application brightness manually If unchecked the brightness will be s
36. loop capacitance 1 0uF Approximately 5km of wire to ground Minimum loop resistance to 1000 Ohm ground NOTE 1 This is the power consumption when none of the powered outputs Page 18 JVA Technologies Pty Ltd www jva fence com are active and the keypad is not connected The rated power consumption may be lower depending on relay configuration and alarm states NOTE 2 The control inputs as supplied with 5V from a weak pull up circuit so that they can be controlled using dry contacts from a relay or switch A device with open collector outputs may be used They can also be driven from a 5V switched output so long as the driving circuit actively pulls down to ground when off NOTE 3 This is the limit for the combination of the loads on both the Si ren and Strobe outputs NOTE 4 This is the maximum rating of the energiser if the ZLM4 is used on the same fence as a high voltage electric fence energiser Beyond this rating the ZLM4 loop circuit protection MOV s may fail if high voltage wires are shorted to the ZLM4 loop wires Lo O M EN SU A Di 5 L JVA ZLM4 Manual Page 19 Val S Q O Uu v v O v ce 9 2 O Lu 6 EQUIPMENT REQUIREMENTS OPTIONS 6 1 REQUIREMENTS e 12V rechargeable backup battery or external 12V source e 16Vac or 24Vdc power adaptor if using internal rechargeable battery 6 2 OPTIONS e 12V Sir
37. nt 1 Ground Voltage Battery Voltage Arm State Alarms Arm High Power JVA ZLM4 Manual ZM1 ID 1 1 1 0 kV 3A 5 0 kV 13 0 V Armed Ground Alarm Al 7N Arm Disarm Low Power De al Wd D un A D lt Lo Q un Page 71 N G gt v x Val A Been o ie N 12 8 7 Program Devices Screen This screen is opened via the Program Devices button in the Site settings This Screen allows an installer to configure each energiser quickly without having to slowly enter key combinations whilst referring to a manual If the site energisers are all running the MK2 protocol you can program each de vice without having to connect to them individually To start Programming choose a device from the list to the left The Keypad will automatically enter programming mode for that device and read its current programmed settings These settings will appear on the list to the right At this point you can begin to edit the settings upon changing them their colour will change to red indicating that you have yet to program these to the Z Series device To do this press the program button After programming the device you may wish to save the currently set up programming options to save time next time To save the configuration press Save to SD Card give the file an appropriate name and press save You can load this configuration back at any time by pressing the Load from SD Card button z Ins
38. of 1 When adding or removing a Z Se ries device to or from the group or if you have changed a device ID be sure to re analyse the group using the key sequence User PIN 6 8 Zone 1 the master must be connected to the group for this operation to work NOTE 1 When re analysing a group ensure all Z Series device are disarmed if they are not this function will not work properly 2 Ifthe group ID has recently been changed you may need to reset User Pin 6 8 before the new ID s will be properly reported to the keypad JVA ZLM4 Manual no Un D D L i A O lt 3 o el L i Page 61 HO UO Megpaadj ajqipny pedAay ysiueds 0 sa3essajy pedAay a3ueyo usi 8ug 0 sa3essa n pedAay 3uey S3UOZ IIV PON Jamod Y3IH 01 U31IAS s uoz IIV SPO Jamod MO 0 YIHMS GT 01 dn Jaq uny uoz UY SI X J uAA X BUOZ UJESIG 191SEN T uoz WeSIG s uoz U WJESIG ST 0 dn Jaquiny uoz UY SI X dau X 9UOZ WY 191Se A T uoz uuv s uoz IY uuv JVA Technologies Pty Ltd SUBIC t Nid Jasn e adueyD poN SUlWWesZ01d 11X3 si wn apo sulwwesso01d 19143 wejy 32u S LISS Zu SNOILINNA QVdA 3 dO AYVINIANS lt l Page 62 Je EEC Z Series Keypads AsOWwaw WJEJE sea iso Alaneg 159 UBJIS 1500g JaMod s jnejag AJOJ2EJ 0 UJNJOH pue jasay Jaq WNN UOISJ A 2JEMUIJIJ Aejdsig pue jasay dno49 ay asAjeue ay JE
39. ours This setting when enabled allows the user to specify a time frame where only the most critical of alarms sound the onboard speaker and brighten the screen In this way the user can have a good nights sleep and deal with any maintenance issues the following morn ing Site Installer Only Installer details by editing this text field you can adjust what is dis played on the home screen under the JVA logo Site Name This setting allows the Site name to be set This name is used when emails are sent and for the file name when the site is saved Clear site this clears all the devices that are currently in the site Save Site This allows the current sites configuration to be saved to the sd card Load Site This setting allows a site s settings to be loaded into the keypad without having to configure the site manually Auto build zones by checking this any devices that are added to the site are automatically detected and displayed by the keypad Program devices This launches the program devices screen which is explained in further detail below Keypad id this is where the keypad id is set Baud rate this is where the baud rate is set Installer pin This setting allows you to change the pin required for log ging on as an installer Zones This shows all the zones in the site that have been detected by the key pad By clicking on each zone they can be renamed to something more intuitive to the user
40. pPo W pedAay Aejdsig HO uO apo 1lu8l ly2eg HO uo s uol 10113 ped y Ho uo uuluo Jadaag ugi ped ay Page 63 JVA ZLM4 Manual 12 8 TOUCH KEYPAD OPERATION 12 8 1 Screens The PTEO230 Touch Keypad consists of the following screens e Home e Alarms e Settings e Events e Zones e Zone Details e Program Devices 12 8 2 Home Screen This is the first screen you are presented with when the ZKeypad Applica tion starts This screen acts as a gateway to all the other screens in the Application 2 A Installer a yy Settings Events Zones Alarms www jva fence com A Le ry A m ay tl Un O o gt Y x vw te wi N 13 Arm Arm Disarm Panic High Power Low Power 10 Page 64 JVA Technologies Pty Ltd www jva fence com Key 1 Home button pressing this at any time returns you to the home screen 2 Back button Pressing this will show the previous screen 3 Site state alarm screen button if the keypad is in alarm launches the Alarm screen otherwise it shows site information 4 Help button launches the keypad help documentation 5 Login logout button provides pin entry dialog if a user is not logged in Or if a user is logged in allows them to logout The above screenshot shows that the installer is logged in 6 Alarms Screen Button Launches the Alarms
41. r an alarm Siren Off Time 4 10 Min Siren Cycles 3 The amount of time the siren will be off for after the on time has expired The number of times the siren will sound for the time set in on time above After this many cycles the siren will automati cally mute Page 44 0 N O Input type Allows the controlinputs to be changed from normally open to normally closed JVA Technologies Pty Ltd www jva fence com Input 2 Function Gate switch 0 Gate Delay 2 1 Min Chime Mode Gate switch open time till alarm Allows the keypad and internal beeper function to be altered Not Used Binary Options 2 siren 0 Miscellaneous options Not Used Not Used Not Used Auto Rearm Time Sets the time which must elapse after an alarm has timed out completed the si ren cycles before the unit will automatically re arm ready for the next alarm event Used to assign an alarm func tion to relay 1 Siren Used to assign an alarm func tion to relay 2 Strobe Relay 2 23 Relay 3 Used to assign an alarm func tion to relay 3 Zone 1 alarm Used to assign an alarm func tion to relay 4 Zone 2 alarm 24 Relay 4 1 25 Relay 5 2 26 Group ID Used to assign an alarm func tion to relay 5 Zone 3 alarm If used as part of a group this sets the device ID Relay 6 0 3 JVA ZLM4 Manual Used to assign an alarm func tion to relay 6 Zone 4 alarm UOI
42. r your PIN and press 8 6 4 When an Alarm Occurs If the system is armed and the fence is tampered with the Fence Light will flash and then remain on A siren or strobe connected to the unit will turn on If the energiser is connected to an alarm system for monitoring an alarm signal will be sent to the alarm company monitoring the alarm system An alarm will also sound if the gate input is opened and the entry exit delay time has elapsed 8 6 5 To Silence an Alarm e Enter your PIN default is 1234 and press This will silence the alarm but not disarm the system the Armed Light will still be on The sys tem will be ready for the next alarm Note that the following functions have an effect on alarm timing Siren On time Siren Off time Siren Cycles Auto Re arm time e The siren and strobe are ready to respond again if triggered e To disarm the system enter your PIN and press again This will also clear the fence alarm light e Alternatively disarming using the magnetic key fob or input switch will reset the alarm e f you silence an alarm and the problem is still present when the unit is rearmed the siren will sound again after the programmed off time has elapsed 8 6 6 To Clear Alarm Memory After an alarm occurs pressing 1 will clear the alarm memory If the problem still exists the unit will alarm again 8 6 7 Changing the PIN Number e Enter the old PIN default is 1234 and press O This enters User P
43. re e Z U N U O Page 22 JVA Technologies Pty Ltd www jva fence com 7 3 FRONT PANEL LCD DISPLAY The 16 character two line display of the ZLM4 clearly shows the status of the fence it is connected to at a glance If you have an LCD keypad attached your can press the to freeze the current displayed information It will re sume after 10 pules have occurred Alternatively you can continue to press the key to iterate through the displays at your own pace 7 3 1 Disarmed When the unit is disarmed you will see the following display In a disarmed state it can also display any alarms it detected when it was last armed This is explained in greater detail below 7 3 2 Armed When armed it cycles through a number of displays J M KA O O 5 JVA ZLM4 Manual Page 23 ke O Se U al vw O 7 3 3 Alarms When a fence alarm occurs additional screens will be added to both the Armed and disarmed state screen rotations Below Zone 1 has been short ed to ground zone 2 has been cut and is now open circuit zone 3 has been shorted to a HV wire only occurs when paired with another Z Series energiser and zone 4 has been shorted to another low voltage zone Ad ditionally the gate has been left open and the battery is either not present or is no longer holding charge 7 4 KEYPAD OPTIONAL A keypad either Touch or LCD can be used to remotely monitor and con trol the ZLM4 It
44. rent keypads that can connect to the keypad bus of a Z Series device e PTEO210 LCD keypad e PTEO230 Touch Keypad Both devices can be used to control program and monitor the devices on your fence 12 1 PTE0210 LCD KEYPAD N Un d A Z 2 m m 5 mej D I 9 Sst y al 2 The PTEO210 is an easy to use durable and economical LCD keypad that can be used to control and program all Z Series devices It displays fence information such as fence voltages battery voltages and any alarms if and when they occur The onboard beeper alerts the user to any issues and instantly shows the relevant information that the user needs to see JVA ZLM4 Manual Page 55 Val G gt Su x Val A Been o Si N 12 2 PTE0230 TOUCH KEYPAD Settings Events www jva fence com AN ZA rm Arm High Power Low Power JVA s most advanced keypad features include e Touch screen with clean user interface designed for ease of use e Quickly arm or disarm the entire site or granularly via the Zones screen e Emails on alarm e View all active and latched alarms in the alarms screen e Program all Z Series devices through an intuitive system without hav ing to remember or refer to a manual for key sequences With the new MK2 protocol these devices can be all programmed together without having to isolate each device individually e Quiet mode set a time where the Keypad won t brighten the screen or set off loud
45. ro gramming mode e Enter your new PIN must be 4 digits and then Repeat to confirm PIN e Press to exit User Programming mode e Make sure your new PIN works by using it to arm the energiser JVA ZLM4 Manual O o et 1 el 5 o lt O 5 N r Page 29 8 6 8 Standby Battery Should there be a loss of mains power the Power light on the keypad will go off The status LED on the ZLM4 front panel will flash twice and the Key pad will show Trouble AC Fail If the loss of power is prolonged the battery may become discharged and become ineffective The Power light on the keypad will start to flash in dicating that the battery charge is low The status LED on the ZLM4 front panel will flash three times and the Keypad will show TROUBLE LOW BAT If the standby battery requires replacement the Status LED on the Ener giser will flash 3 times even after the mains power has been restored 8 6 9 Internal Beeper Keypad Beeper Depending on the Chime Mode setting the internal beeper and keypad beeper will sound when there is a fence alarm a gate alarm a general alarm or a door chime On flat battery the keypad will always beep 4 times before the energiser automatically enters low power mode to preserve the battery On AC Fail it will not beep Note The Internal beeper also beeps at Power up 8 6 10 ZLM4 Relevant Keypad Codes The default user pin is 1234 The default installer pin is 012345
46. s an alarm sounding you will need to enter your User PIN twice once to silence the alarm and once more to disarm 12 3 4 Menus The Z Series keypad has an optional menu driven interface The main menu is accessed by pressing the Menu key bottom right You will be asked to enter your PIN and then press JVA ZLM4 Manual g Un D L i A lt 3 o o U Page 57 N gt x Val A Been o Si N Most functions are available via the menus Use the 2 key to go up and the 8 to step down through a menu The Enter key is used to select the current line The menu will time out after a few minutes and return to the normal status display 12 3 5 Keypad Status Display In normal operation the keypad shows a continuous summary of the sys tem status For example if the system is disarmed the keypad will display Ready to Arm If the system is armed then the keypad will display the voltages for each zone in the system Since there can be many things to display the keypad automatically scrolls through all relevant information Each screen is shown for about 2 seconds If you wish to hold the display at a particular point simply press the key The auto scrolling will stop for about 20 seconds Pressing the key again will advance the display one step If a new trouble AC fail low battery etc or alarm occurs the keypad screen will jump to the relevant zone the keypad will
47. t to Door Chime the beepers will sound when the gate switch opens even if the energiser is disarmed If set to Siren the beepers mimic the siren function Gate Beeps plus Siren will give 2 beeps on Gate open and 4 on close plus continuous for an alarm Beeps are on Keypad only not internal beeper None Door Chime sa Gate beeps plus Siren 11 3 14 Binary Options 16x Each option in this table can be turned on by adding the value For option 1 set 16 to 01 for 1 and 2 set 16 to 03 1 Disable Proximity switch The magnetic reed switch on the display board will be disabled 2 Enable Siren Acknowledge The siren will chirp once for armed and twice for disarmed 4 Enable to stop bad battery alarms if you are not using a battery Added in version 1 2 1 Disable prox switch 2 Siren codes No battery Page 50 JVA Technologies Pty Ltd www jva fence com 11 3 15 Auto Re Arm time 20x This option sets the time which must elapse before another alarm will sound after the first alarm has timed out gone completely through its cycles If an event occurs which triggers the siren any other events which would otherwise trigger the siren such as a gate alarm will be ignored while the siren is sounding and until after the Auto re arm time has passed A setting of 9 will disable auto re arm The default is 0 Seconds Immediate immediate 30 Seconds 3 Min
48. tall a Programming Screen ka Devices m2 Options Firmware 1v61 Fence Alarm Level 20 Amps Ground Voltage Alarm Level Fence Cut Alarm Level Load from SD card Save to SD Card Reading device options Program Screenshot above showing when a device is first selected from the left list Page 72 JVA Technologies Pty Ltd www jva fence com e II Programming Screen Ka installer Devices Options Relay 5 Firmware 1v61 Group Mode ID Balance Factors Sector Data Load from SD card Save to SD Card Programming device Program Screenshot above showing changed values turning to red a Programming Screen PP Devices Options x Firmware 1v61 Relay 5 General Group Mode ID 1 Master Balance Factors 4 bytes location 100 Device programmed successfully 16 bytes location 104 Load from SD card Save to SD Card Read successful Program Screenshot above showing a devicethat has been successfully programmed i L D 5 Wa L i A D lt fo o U JVA ZLM4 Manual Page 73 13 APPENDICES 13 1 APPENDIXA Z A 7 r Y nu f E fe Z RA Dy W l N m all Ze gej ol o lt 2 N A I N E x o E Hey a Xe 5 Z y of ap NE zs x Z ki Lavy Page 74 JVA Technologies Pty Ltd www jva fence com 13 2 APPENDIX B A B Keypad 12U Data RS485 12U gt ke ie D
49. the Webserver GSM and PC control software may override the Control input and Keypads methods depending on the options used If you need to make sure that fence is dis armed for maintenance then using the Key switch or keypad alone may not guarantee that the fence will remain disarmed 8 2 MAGNETIC PROXIMITY SWITCH The ZLM4 may be controlled using the JVA permanent magnet key ring fob To operate the fob must be held against the control zone marked on the front label The energiser will beep and toggle from armed to disarmed or vice versa after the fob is swiped slowly over the sensitive area The mag netic proximity receiver should be disabled in the programmable options if it is not being used Page 26 JVA Technologies Pty Ltd www jva fence com 8 3 PC CONTROL A standard Windows PC may be used to control and monitor a group of Z Series energisers Ask your JVA installer for a demonstration of Perimeter Patrol software 8 4 WEB SERVER Another alternative to remotely controlling JVA Z Series energisers is to use the PAE225 Webserver When suitable configured this allows the ener giser to be controlled and monitored via a web browser from any internet connected device anywhere in the world Note The ZLM4 is not supported by older versions of the webserver 8 5 KEYPAD The ZLM4 and other devices connected on the same keypad bus can be controlled via a keypad For more information see 8 6 Controlling the ZLM4 using
50. the confidence security professionals are placing in this form of perimeter security The reason for this popularity is simple monitored electric secu rity fences are effective economical simple to install and they offer more D s of security than any other perimeter system DEMARCATION The JVA electric fence around your property shows you mean business DEFLECTION Intruders are deflected to softer targets DETERRENCE When used in conjunction with a Z Series HV energiser the safe powerful JVA shock is a strong deterrent to intruders DELAY The barrier will help delay an intruder giving you more time to react DETECTION The JVA s voltage monitor warns you of any tampering with the fence DEPENDABLE 60 seconds a minute 60 minutes an hour 24 hours a day 365 days a year your JVA electric security fence is monitored by an alert sober electronic watchman The ZLM4 is a 4 zone low voltage electric fence monitor The ZLM4 may be used by itself or in conjunction with a number of high voltage security electric fence energisers The ZLM4 monitors up to 4 loops of fence wire each up to several hundred meters long to detect someone tampering with the fence by cutting or shorting the wires When used in conjunc tion with a high voltage electric fence energiser the ZLM4 is wired to the non energised earth wires on the fence In this way the ZML4 can be used to split one high voltage zone into up to 4 low voltage monitore
51. tory settings remove all power AC and battery and re move the J4 jumper Reapply the Jumper Off to return programmable op tions to factory de mains and the battery power Re faults on power up apply the J4 jumper after it has completed powering up and the Energiser will be reset to default settings Inhibits the onboard If you want to disable the onboard beeper beeper simply place the jumper over both pins By default it is only placed over 1 pin v 9 5 UO Bn gej UN Ss sei ej Page 8 JVA Technologies Pty Ltd www jva fence com 1 5 FREQUENTLY USED LCD KEYPAD COMMANDS For a full list of all keypad commands please see 8 6 10 ZLM4 Relevant Keypad Codes on page 30 NOTE The default user PIN is 1234 andthe default installer PIN is 012345 Arm Disarm User PIN Installer PIN 0 Exit Programming Arm All Zones Multi zone User PIN 1 0 groups Arm Zone x where x is any zone User PINJ 1 x H number up to 15 Disarm all Zones User PIN 2 0 Disarm Zone x Where x is any User PIN 2 x zone number up to 15 STD JVA ZLM4 Manual Q re 104 et te J rt CO 3 Q 4 Page 9 G U OH o gt 2 INTRODUCTION Thank you for purchasing a JVA security Low voltage monitor The growing use of non lethal electric security fences around the world is indicative of
52. ured as a Siren turning on for fence alarms for a pre configured length of time 5 This output is configured as a Strobe This will turn on for alarms and remain on even after the alarm has been resolved This is to notify you that there has been an issue with the fence This can be cleared by disarming and rearming the fence or if you have an LCD keypad by typing in the clear alarm command 6 This is the 16V AC input Alternatively a 24Vdc 1 5A supply can be used instead The correct connection is 24V to the right AC pin and GND to the left AC pin Due to the stored energy in a 24Vdc plug pack an AC Fail may take up to 5 minutes to be reported 7 These are the relay outputs By default relay 3 is set to switch for a loop 1 fence alarm relay 4 is set to switch for a loop 2 fence alarm relay 5 is set to switch for a loop 3 fence alarm and finally relay 6 is set to switch for a loop 4 fence alarm 13 WIRING UP YOUR ZLM4 This is covered under 10 Wiring Diagrams on page 38 After the ZLM4 has been wired up you can begin to protect your perimeter je re L et DI et CO Q Wd JVA ZLM4 Manual Page7 1 4 JUMPERS Jumpers quickly allow you to turn on and off different features or reset the device to defaults These are explained in the table below If you are not using 16Vac 12V battery power only place a jump er over both pins Factory default If the energiser needs to be de faulted to fac
53. utes 4 Minutes 6 Minutes 7 Minutes Disabled Do not auto rearm 1 4 6 7 So 11 3 16 Relay Functions All relays can be set to any of the available functions user assignable Relay 1 is 21x Relay 2 is 22x etc JVA ZLM4 Manual D A gt A gt e 3 e gt Page 51 lt 2 Ce gt 2 te is Q NOTE Relay 6 is 27x Defaults for the ZLM4 e Relay 1 Siren 8 Relay 2 Strobe 9 e Relay 3 Zone 1 Alarm 0 e Relay A Zone 2 1 e Relay 5 Zone 3 2 e Relay6 Zone4 3 Note The siren and strobe switched 12V outputs can be used to drive ex ternal buffer relays C Zone 2 alarm SE Zone 4 alarm eS Un used SEH N w ani un General i tr era 10 AC Fail 11 Low Bad Battery 13 Un used Siren caused by Gate Alarm wjo IN Page 52 JVA Technologies Pty Ltd www jva fence com Zone x Alarm The ZLM4 is Armed AND Any zone alarm occurs these in clude 20 The loop return Voltage has fallen below the Fence Voltage Alarm Level Low Voltage 21 High voltage has been detected shorted to high volt age wires for more Energiser pulses than the Missed Pulse Count setting Not latched Armed The ZLM4 is Armed General AC Fail OR Tamper OR Low Battery OR Gate Alarm OR In ternal Error Latched for internal errors only Siren Fence Alarm OR Gate