Home
5SC 500i 5SC 750i 5SC 1000i 5SC 1500i Installation and user
Contents
1. 1 In low sensitivity mode Lo UPS will tolerate more fluctuations in power and will go on battery power less often If the connected load is sensitive to power disturbances keep the sensitivity as Standard Std Page 6 619 00470 01 i en 3 Installation 3 1 Unpacking and contents check 1 5SC UPS 2 Quick start and safety instructions 3 User manual and IPSS Intelligent Power Software Suite CDROM 4 2 connection cables for the protected equipment 5 RS232 communication cable 6 USB communication cable Packing materials must be disposed of in compliance with all local regulations concerning waste Recycling symbols are printed on the packing materials to facilitate sorting 619 00470 01 i en Page 7 3 Installation 3 2 Communication ports Connection of RS232 or USB communication port The RS232 and USB communication ports cannot operate simultaneously D GZ M Characteristics of the optocoupler RS232 communications port tt 1 Connect the RS232 5 or USB 6 communication cable to the serial or USB port on the computer equipment 2 Connect the other end of the communication cable 5 or 6 to the USB 1 or RS232 2 communication port on the UPS The UPS can now communicate with EATON power management software e Pins 1 3 4 5 6 10 not used e Pin 2 common user e Pin 7 low battery e Pin 8 operation on battery
2. E T M Installation and user manual 5SC 5001 5SC 7501 5SC 10001 5SC 15001 Certification Standards UPS directives e Safety IEC 62040 1 2008 e EMC IEC 62040 2 2005 e Performance IEC 62040 3 2010 CE mark EN 62040 1 2008 and EN 62040 2 2006 C1 Class B emission level CISPR 22 2005 A2 2006 EN 55022 Harmonics emission IEC 61000 3 2 edition 3 2 2009 Flickers emission IEC 61000 3 3 edition 2 2008 Special Symbols mM el e Pb Px Page 2 The following are examples of symbols used on the UPS or accessories to alert you to important information RISK OF ELECTRIC SHOCK Observe the warning associated with the risk of electric shock symbol Important instructions that must always be followed Do not discard the UPS or the UPS batteries in the trash This product contains sealed lead acid batteries and must be disposed as it s explain in this manual For more information contact your local recycling reuse or hazardous waste center This symbol indicates that you should not discard waste electrical or electronic equipment WEEE in the trash For proper disposal contact your local recycling reuse or hazardous waste center Information advice help 619 00470 01 i en Contents LAN TOUCH arenosa ii 4 11 Environmental Protec red rieron arde 4 2 Presentation oo 5 slo nn 5 RAN e IVS Sa POPE PP n o O e no eaepoh abou A NT 5 A A 6 E E r rA A a aioe danebat ea ttetace soe 6
3. OS TRI Ip OUI Ne LOD esten iia 6 3 Installation crias 7 3 Unpacking and Contents CMG kararri da aeaa eitada ieith 7 Sl COMPMUNICAT ON DOS tuerce ica ce oscura 8 4 Opera ON ico orion dla 9 4 1 Start up and Normal OPeratiON occcocccccccccccccnnncncnnccononononononononnnnnnnnnnonnnnnnnnnnnnnnnonnnnnonnnnnenons 9 Alaior do us soinera O eoneedentvanncayess 9 EA Ol IO S a AA OA o Co o O A 9 AA Operation on Battery POWED esenranicionndinna cian sia derrito ica 9 AO Returner Or AG MUR IP OW a dci 9 5 Maintenance cccccecceceeeceeeeeceeceeeeeceeceeceeceeeseeneceeneeneeneeueneeesenes 10 DA MMU NS ROON ecarten aeiia a a aaia aginst Raia 10 5 2 Battery module replacement 0 cece cece cece ccc e seca cece eeeeeeeseeese ees eeese seas eeeeeeeeeeseeeeeeenaeeseeeens 11 FAD DOING CS sist pa atajar icon 12 6 1 Technical Specialist 12 619 00470 01 i en Page 3 1 Introduction Thank you for selecting an EATON product to protect your electrical equipment The 5SC range has been designed with the utmost care We recommend that you take the time to read this manual to take full advantage of the many features of your UPS Uninterruptible Power System Before installing 5SC please read the booklet presenting the safety instructions Then follow the instructions in this manual 1 1 Environmental protection Page 4 EATON has implemented an environmental protection policy Products are developed according to an eco design appro
4. power e Pin 9 UPS ON equipment supplied n o normally open contact When a signal is activated the contact is closed between the common pin 2 and the pin for the corresponding signal Contact characteristics optocoupler e Voltage 48V DC max e Current 25 mA max e Power 1 2 W Page 8 619 00470 01 i en 4 Operation 4 1 Start up and Normal operation To start the UPS 1 Verify that the UPS power cord is plugged in 2 Press the button on the UPS front panel for at least 2 seconds 3 Check the UPS front panel display for active alarms If the A indicator is on do not proceed until all alarms are cleared Correct the alarms and restart if necessary 4 Verify that the indicator illuminates solid indicating that the UPS is operating normally and any loads are powered and protected 4 2 Starting the UPS on Battery il Before using this feature the UPS must have been powered by utility power with output enabled at least once To start the UPS on battery 1 Press the D button on the UPS front panel until the UPS front panel display illuminates The UPS cycles through Standby mode to Battery mode The indicator illuminates solid The UPS supplies power to your equipment 2 Check the UPS front panel display for active alarms Resolve any active alarms before continuing See Troubleshooting on page 10 4 3 UPS Shutdown To shut down the UPS 1 Press the D button on the front panel fo
5. separating the two connectors never pull on the wires C Remove the plastic protection cover in front of the battery one screw D Pull the plastic tab to remove the battery block and replace it Mounting the new battery module Carry out the above instructions in reverse order N e To ensure safety and high performance use only batteries supplied by EATON e Take care to firmly press together the two parts of the connector during remounting 619 00470 01 i en Page 11 6 Appendices 6 1 Technical specifications Page 12 Transformer Filter AVR Charger Inverter KH NN Battery 5SC 500i 5SC 750i 5SC 1000i 5SC 1500i Output Power 500 VA 750 VA 1000 VA 1500 VA 230 V 350 W 525 W 700 W 1050 W AC Input power e Rated input voltage Single phase 220 240 V e Input voltage range 184 to 276 V e Input frequency 45 to 55 Hz 50 Hz system 55 to 65 Hz 60 Hz system range Output on battery power e Voltage 220 230 240 V 10 6 e Frequency 50 60 Hz 0 1 Hz Battery sealed lead acid maintenance free e Standard 1x12V 2x12V 2x12V 3x12V 9 Ah 7 Ah 9 Ah 9 Ah Environment e Operating 0 to 35 C 32 to 95 F temperature range e Storage 15 to 40 C 5 to 104 F temperature range e Relative humidity 0 to 90 without condensation e Noise level lt 40 dBA in normal mode 1 Adjustable to 220 230 240 V must be set to the identical AC power source value When the applian
6. 10 40 22 90 340 x 150 x 210 13 4 x 5 9 x 8 3 5SC 1000i 11 10 24 50 340 x 150 x 210 13 4 x 5 9 x 8 3 5SC 1500i 15 20 33 50 410 x 150 x 210 16 1 x 5 9 x 8 3 2 2 Rear panels 5SC 500i 5SC 750i 1 USB communication port 2 RS232 communication port 3 Outlets for connection of critical equipment 4 Socket for connection to AC power source 5 Ground screw 619 00470 01 i en Page 5 2 Presentation 2 3 Control panel The UPS has a three button LCD It provides useful information about the UPS itself load status events measurements and settings Ad vr A i oN O D tte e 0 0 0 2 4 LCD description INS AVR AN _ AN E z H Min Hz gt SH kVA i Pil kW 2 5 UPS setting through the LCD Release scroll down button to select menu Output voltage Alarm N C3 ELE rer FF CJ O gt ne X 10s Save the new value e LCD will shut off if there is no activity for 3 minutes A 2s eee Zas gt gt gt WUE ML i ON OFF button 7 Scroll down Mute alarm a UPS ON AVR mode 4 Battery mode 42 Internal fault 43 Output load level 44 Battery level 4a Input measurements 48 Output measurements 47 Measuring unit LY EA JCM Sensitivity
7. ach Substances This product does not contain CFCs HCFCs or asbestos Packing To improve waste treatment and facilitate recycling separate the various packing components e The cardboard we use comprises over 50 of recycled cardboard e Sacks and bags are made of polyethylene e Packing materials are recyclable and bear the appropriate identification symbol oor PET Abbreviations Number in E the symbols Polyvinyl chloride PVC Follow all local regulations for the disposal of packing materials End of life EATON will process products at the end of their service life in compliance with local regulations EATON works with companies in charge of collecting and eliminating our products at the end of their service life Product The product is made up of recyclable materials Dismantling and destruction must take place in compliance with all local regulations concerning waste At the end of its service life the product must be transported to a processing centre for electrical and electronic waste Battery The product contains lead acid batteries that must be processed according to applicable local regulations concerning batteries The battery may be removed to comply with regulations and in view of correct disposal 619 00470 01 i en 2 Presentation 2 1 Standard installation Description Weights kg lo Dimensions mm inch DxWxH 5SC 500i 6 60 14 60 240 x 150 x 210 9 4 x 5 9x 8 3 5SC 750i
8. ce is used in EU area use an external circuit breaker in front of line with rating 16A 250 V which is IEC EN 60898 1 standard compliant When the appliance is used in America area use an external circuit breaker in front of line with rating 20 A 250 V This product is designed for IT power distribution system 619 00470 01 i en
9. r three seconds The UPS starts to beep The UPS then transfers to Standby mode and the indicator turns off 4 4 Operation on Battery Power Transfer to battery power e The connected devices continue to be supplied by the UPS when AC input power is no longer available The necessary energy is provided by the battery e The indicator illuminates solid e The audio alarm beeps every ten seconds il The connected devices are supplied by the battery Low battery warning e The indicator illuminates solid e The audio alarm beeps every three seconds The remaining battery power is low Shut down all applications on the connected equipment because automatic UPS shutdown is imminent End of battery backup time e All the LEDs go OFF e The audio alarms stops 4 5 Return of AC Input Power Following an outage the UPS restarts automatically when AC input power returns unless the restart function has been disabled and the load is supplied again 619 00470 01 i en Page 9 5 Maintenance 5 1 Troubleshooting Operation status Overload Possible cause Power requirement exceeds the UPS capacity greater than 105 of nominal Action Remove some of the equipment from the UPS The UPS continues to operate but may shutdown if the load increases The alarm resets when the condition becomes inactive Short circuit fault A short circuit occurred Check device connection or integrity If error persist
10. s note the alarm message and the UPS serial number and then contact your service representative Battery fault The batteries in the UPS are disconnected Verify that all batteries are properly connected OL If error persists note the alarm Cir message and the UPS serial number and then contact your service representative The end of battery life is reached Contact your service representative for battery replacement Fan fault The UPS has a fan fault Check that no object is blocking the fan roe Fo FU If error persists note the alarm Charger fault The UPS has a charger fault message and the UPS serial number and then contact your service representative The UPS does not charge the battery anymore Note the alarm message and the UPS serial number and then contact your service representative Page 10 619 00470 01 i en 5 Maintenance 5 2 Battery module replacement Safety recommendations The battery can cause electrocution and high short circuit currents The following safety precautions are required before servicing the battery components e remove watches rings bracelets and all other metal objects from the hands and arms e use tools with an insulated handle Battery tray removal on tower models This operation must be performed when the UPS is switched OFF and unplugged from AC source OOOO ah A Remove the front panel B Disconnect the battery block by
Download Pdf Manuals
Related Search
Related Contents
Reelcraft Series PW80000 Pressure Wash Reel Moneta 0000720120 cooking pan IRTC50 - General Tools And Instruments Fluke - Rekirsch Elektronik Ventura Dokument - Panasonic Biomedical DE Prontosan® Wound Spray IT Prontosan® Wound Spray GB Secretaria da Educação do KitchenAid KGCK306 User's Manual Copyright © All rights reserved.