Home
BR650ELCD / BR850ELCD User's Manual
Contents
1. CAUTION To avoid electrical shock turn off the unit and unplug it from the AC power source before servicing the battery or installing a computer component CAUTION DO NOT USE WITH OR NEAR AQUARIUMS To reduce the risk of fire do not use with or near aquariums Condensation from the aquarium can come in contact with metal electrical contacts and cause the machine to short out INSTALLING YOUR UPS SYSTEM UNPACKING The box should contain the following 1 UPS Unit x 1 2 Phone Line x 1 3 USB Cable x 1 4 User Manual x 1 5 Management software Disk x 1 6 Cable Collector x 1 OVERVIEW The BR650ELCD BR850ELCD provides automatic voltage regulation for inconsistent utility power The BR650ELCD BR850ELCD features 405 Joules of surge protection and provides battery backup during power outages The BR650ELCD BR850ELCD ensures consistent power to your computer system and its included software will automatically save your open files and shutdown your computer system during a utility power loss HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT 1 Make sure that the total Volt Amp VA requirements of your computer monitor and peripheral equipment does not exceed 650VA 850VA 2 Ensure that the equipment plugged into the battery power supplied surge outlets does not exceed the UPS unit s rated capacity 650VA 390W for BR650ELCD 850VA 510W for BR850ELCD If the rated unit capacities are exceeded an overload condition may
2. S E E S N S S E E E A a 4th ae a ieee a et ae CX Press gt 3sec Sound Disable Press gt 3sec again Baand Enable Overload V X y Illuminated Battery mode UPS Status Display Select SW oth Return eam Gene Oca an Press gt 3sec Sound Disable Press gt 3sec again Sound Enable Overload X V y Illuminated X Not Illuminated Either Capacity Display Digital Value oa Load Battery Input Output Run a Ma Maa 2 Time L toad 4 Ba at one Od ral eat B X Not Illuminated _ Either TROUBLESHOOTING Problem Possible Cause Somon Full time surge protection outlets stop providing power to equipment Circuit breaker button is projecting from the side of the unit The UPS does not perform expected runtime The UPS will not turn on PowerPanel Personal Edition is inactive Circuit breaker has tripped due to an overload Battery not fully charged Battery is slightly worn out The on off switch is designed to prevent damage by rapidly turning it off and on The battery is worn out Mechanical problem The USB cable is not connected The unit is not providing battery power Turn the UPS off and unplug at least one piece of equipment Wait 10 seconds reset the circuit breaker by depressing the button and then turn the UPS on Recharge the battery by leaving the UPS plu
3. CyberPower Reliability Quality Value BR650ELCD BR850ELCD User s Manual K01 0000180 00 IMPORTANT SAFETY INSTRUCTIONS This manual contains important instructions that should be followed during installation and maintenance of the UPS and batteries Please read and follow all instructions carefully during installation and operation of the unit Read this manual thoroughly before attempting to unpack install or operate CAUTION The UPS must be connected to a grounded AC power outlet with fuse or circuit breaker protection DO NOT plug the UPS into an outlet that is not grounded If you need to de energize this equipment turn off and unplug the UPS CAUTION DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT CyberPower Systems does not sell products for life support or medical applications DO NOT use in any circumstance that would affect the operation or safety of any life support equipment with any medical applications or patient care CAUTION The battery can energize hazardous live parts inside even when the AC input power is disconnected CAUTION To prevent the risk of fire or electric shock install in a temperature and humidity controlled indoor area free of conductive contaminants Please see specifications for acceptable temperature and humidity range CAUTION To reduce the risk of electric shock do not remove the cover except to service the battery There are no user serviceable parts inside except for the battery
4. ators Power On LCD Display Audible Alarms On Battery Low Battery Overload Communication PowerPanel Personal Windows 7 Vista XP 2000 Server 2003 Linux Edition Software CYBERPOWER GREENPOWER UPS TECHNOLOGY CyberPower s Green Commitment CyberPower is dedicated to the development of green products and has adopted Green practices throughout its business including membership in Climate Savers Computing Initiative CSCI accordance with the Restriction on Hazardous Substances ROHS Waste Electrical and Electronic Equipment WEEE protocols as well as ISO 14001 and IECQ QC080000 CyberPower pledges to provide the ENERGY SAVING advanced energy solution for the environment and become a leading eco friendly organization in the UPS industry TECHNOLOGY Reduce Energy Cost with GreenPower UPS Technology CyberPower s goal is not only to provide eco friendly products but also to bring the best value for consumers The advanced energy saving design improves the operating_efficiency and eliminates waste energy consumption As a result consumers will enjoy significant energy cost savings with the adoption of GreenPower UPS technology DEFINITIONS FOR ILLUMINATED LCD INDICATORS Line mode UPS Status Display Select SW 5 ox OE Di Capacity Display Digital Value Display Load Battery Input Output Run T E n a 2 Ba Load d ean S e r en S m a no a
5. gged in Contact CyberPower Systems about replacement batteries at service cpsww com au Turn the UPS off Wait 10 seconds and then turn the UPS on Contact CyberPower Systems about replacement batteries at service cpsww com au Contact CyberPower Systems at service cpsww com au Connect the USB cable to the UPS unit and an open serial port on the back of the computer You must use the cable that came with the unit Shutdown your computer and turn the UPS off Wait 10 seconds and turn the UPS back on This should reset the unit Additional troubleshooting information can be found at www cpsww com au For more information visit www cpsww com au or contact CyberPower Systems E MAIL sales cpsww com au All rights reserved Reproduction without permission is prohibited ez A
6. ith large electrical demands e g air conditioner refrigerator copier etc Avoid using extension cords 6 Depress the power switch to turn the unit on The power on indicator light will illuminate and the unit will beep 7 lf an overload is detected an audible alarm will sound and the unit will emit one long beep To correct this turn the UPS off and unplug at least one piece of equipment from the battery power supplied outlets Wait 10 seconds Make sure the circuit breaker is depressed and then turn the UPS on 8 To maintain optimal battery charge leave the UPS plugged into an AC outlet at all times 9 To store your UPS for an extended period cover it and store with the battery fully charged Recharge the battery every three months to ensure battery life BASIC OPERATION DESCRIPTION Power On Off Switch Press the power switch to turn the UPS ON or OFF LCD Function Selected Switch Press the LCD function selected switch to know the UPS status LCD Display The LCD will display the UPS status including input voltage output voltage runtime percentage of load and battery etc Communication Protection Ports RJ11 RJ45 Communication protection ports will protect any standard modem fax telephone line or network cable from surge and spikes AC outlets The UPS provides 3 outlets for connected equipment to insure temporary uninterrupted operation during a power failure and against
7. occur and cause the UPS unit to shut down or the circuit breaker to trip HARDWARE INSTALLATION GUIDE 1 Your new UPS may be used immediately upon receipt However after receiving a new UPS to ensure the battery s maximum charge capacity it is recommended that you charge the battery for at least 8 hours Your UPS is equipped with an auto charge feature When the UPS is plugged into an AC outlet the battery will automatically charge whether the UPS is turned on or turned off 2 If you will use the software connect the USB cable to the USB port on the UPS 3 With the UPS unit off and unplugged connect the computer monitor and any externally powered data storage device Zip drive Jazz drive Tape drive etc into the battery power supplied outlets DO NOT plug a laser printer copier soace heater vacuum paper shredder or other large electrical device into the battery power supplied outlets The power demands of these devices will overload and possibly damage the unit 4 To protect a fax telephone modem line or network cable connect a telephone cable or network cable from the wall jack outlet to the IN jack of the UPS Then connect a telephone cable or network cable from the OUT jack on the UPS to the modem computer telephone fax machine or network device 5 Plug the UPS into a 2 pole 3 wire grounded receptacle wall outlet Make sure the wall branch outlet is protected by a fuse or circuit breaker and does not service equipment w
8. surges and spikes and another 3 outlets against surges and spikes only USB Port to PC 0 This port allows connection and communication n n LS from the USB port on the computer to the UPS unit m sss The UPS communicates its status to the i PowerPanel Personal Edition software er z Input Circuit Breaker The Circuit Breaker provides optimal overload protection Power on LED The power on LED lights up when the UPS is ON Q Cable Collector Collect the cables connected from the AC outlets in the cable collector TECHNICAL SPECIFICATIONS Capacity VA Capacity Watts npt o Input Voltage Range Frequency Range AVR Function Output ON Batey Oui Simulated Sine Wave at 230Vac 10 Voltage 50 60Hz 1 On Battery Output Frequency Transfer Time On Utility Circuit Breaker and Internal Current Limiting On Battery Internal Current Limiting Overload Protection Surge Protection Lightning Surge Yes Protection RJ11 RJ45 One In One Out Network Phone Fax Modem Protection Operating Temperature Operating MEANE 0 to 90 non condensing Humidity Total of UPS outlets Maximum 271 x 160 7 x 113 6mm Dimensions LxWxH Weight kg 6 4 Battery Sealed Maintenance Free Lead Acid Battery 12V 7Ah x1 12V 8 5Ah x1 Typical Recharge Time User Replaceable Status Indicators Indic