Home

USER MANUAL Universal Gateway U9921-GUV U9921

image

Contents

1. radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and the receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help You may also find helpful the following booklet prepared by the FCC How to Identify and Resolve Radio TV Interference Problems This booklet is available from the U S Government Printing Office Washington D C 20402 In order to maintain compliance with FCC regulations shielded cables must be used with this equipment Operation with non approved equipment or unshielded cables is likely to result in interference to radio amp television reception 8 of 10 19541P 42 04 11 Industry Canada Statement This device complies with Industry Canada licence exempt RSS standard s Operation is subject to the following two conditions 1 this device may not cause interference
2. Kit P N 41045G 01 Care and Maintenance The U9921 GUV is not user serviceable Do not attempt to open the enclosure If this product requires service please contact the David Clark Customer Service department 19541P 42 04 11 Phone 800 298 6235 E Mail serviceWWW DavidClark com By Mail Customer Service David Clark Company 360 Franklin Street Worcester MA 01604 7 of 10 If necessary the U9921 GUV may be wiped down with a mild soap and water mixture Although it is a sealed device designed to withstand submersion in water to 1 meter do not unnecessarily submerse this product in water Avoid storage of this product in direct sunlight or high temperature environments Specifications Frequency Range 1920 MHz 1930 MHz U S and Canada 1880 MHz 1900 MHz EU Average RF Power Output 4 mW 100mW peak U S and Canada 10 mW 250 mW peak EU Range 300 ft 100m line of sight nominal Operating Temperature 14 F to 113 F 10 C to 45 C Storage Temperature 4 F to 140 F 20 C to 60 C Power Requirements 8 to 25VDC FCC Part 15 Statement RADIO AND TELEVISION INTERFERENCE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can
3. and 2 this device must accept any interference including interference that may cause undesired operation of the device Unauthorized Changes Changes or modifications not expressly approved by David Clark Company Inc could void the users authority to operate the equipment FCC Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with a minimum distance of 20 centimeters 8 inches between the radiator antenna and your body This transmitter must not be co located or operating in conjunction with any other antenna or transmitter Usage Restrictions US Models Due to the UPCS frequencies used this product is licensed for operation only in the United States of America and Canada EU Models Due to the DECT frequencies used this product is licensed for operation only in the European Union countries 9 of 10 19541P 42 04 11 Appendix A Mounting Templates Figure A2 Bracket Mount Optional P N 41045G 01 19541P 42 04 11 10 of 10
4. 21 GUV may be flush mounted or surface mounted using the included gasket nut and bracket See Figure 1 for mounting suggestions Note Bracket P N 41045G 01 optional Not used for flush mount applications Bracket mounting configuration may be reversed for varying requirements e g vehicle dash vs ceiling mount See Appendix A for Mounting Templates Antenna The U9921 GUV has an internal antenna An external antenna may not be necessary but the antenna connector is provided for either the included whip antenna or an optional remote antenna kit P N 40688G 93 for mag mount 40688G 96 for permanent install Choose an open clear location for the remote antenna and route the coaxial cable away from any busy areas preferably behind panels or in conduits This device has been designed to operate with the antennas listed below and having a maximum gain of 3 dB Antennas not included in this list or having a gain greater than 3 dB are strictly prohibited for use with this device The required antenna impedance is 50 ohms 3 of 10 19541P 42 04 11 Acceptable antennas for use with this product Linking e Whip Antenna P N 40688G 92 e Remote Antenna Kit Mag Mount P N 40688G 93 e Remote Antenna Kit Permanent P N 40688G 96 Before a belt station and a gateway can be connected they must first be linked As a security measure the close link feature requires devices to be in proximity of between 1 to 3 ft 0 3 to 0 9m in
5. d in conjunction with one or more U9910 BSW 40992G 01 or U9912 BSW 40992G 02 Wireless Belt Stations becomes part of a wireless intercom system The U9921 GUV provides communication for up to four users as well as an interface to an existing wired intercom system Up to four belt stations can be connected to one gateway Antenna Connection Status LED Threaded Post Interface Connector C UNIVERSAL GATEWAY ot Figure 1 Overview of Gateway 2 of 10 19541P 42 04 11 Installation Intercom Interface The U9921 GUV is designed to add wireless capability to an existing wired intercom Connection to the intercom is accomplished by connecting an interface cable to the interface connector of the U9921 GUV see Figure 1 The following list contains David Clark intercom systems that have been tested to work with the U9921 GUV and the required cable assembly Table 1 Intercom Interface Cable Assemblies David Clark Intercom Cable Assembly Required U3800 Vehicular Intercom System C99 22MS 40935G 08 U9800 Marine Intercom System C99 20CX 40935G 07 U9500 Marine Intercom System C99 20LL 40935G 06 U3400 Portable Intercom System U3100 Modular Intercom System C99 20MS 40935G 05 The U9921 GUV will detect the cable assemblies listed above and automatically make the necessary audio level adjustments for the corresponding intercom Mounting The U99
6. e David Clark WWW DAVIDCLARK COM USER MANUAL Universal Gateway U9921 GUV U9921 GUV EU P N 40994G 01 P N 40994G 02 19541P 42 04 11 2011 DAVID CLARK COMPANY INCORPORATED Cautions and Warnings 19541P 42 04 11 READ AND SAVE THESE INSTRUCTIONS Follow the instructions in this installation manual These instructions must be followed to avoid damage to this product and associated equipment Product operation and reliability depends on proper usage Y N amp x DO NOT INSTALL ANY DAVID CLARK COMPANY PRODUCT THAT APPEARS DAMAGED Upon unpacking your David Clark product inspect the contents for shipping damage If damage is apparent immediately file a claim with the carrier and notify your David Clark product supplier ELECTRICAL HAZARD Disconnect electrical power when making any internal adjustments or repairs All repairs should be performed by a representative or authorized agent of the David Clark Company STATIC HAZARD Static electricity can damage components Therefore be sure to ground yourself before opening or installing components LI POLYMER This product is used with Li Polymer batteries Do not incinerate disassemble short circuit or expose the battery to high temperatures Battery must be disposed of properly in accordance with local regulations 1 of 10 Overview The U9921 GUV 40994G 01 Universal Gateway is a fixed mounted wireless communication device that when use
7. e belt station User Manual for the individual belt station purging procedure when remaining link purging may be necessary Smart Purge procedure 1 Ensure the gateway is powered on and functioning Disconnect all belt stations to be purged power off the belt stations 3 Verify the number of green LED flashes on the gateway matches the number of belt stations to be kept linked 4 Press and hold LINK button on the gateway for 30 seconds until LED quickly flashes red 5 Release LINK button m 6 of 10 19541P 42 04 11 Troubleshooting Table 3 Troubleshooting Problem Solution Gateway will not turn on Ensure correct interface cable is being used Table 2 Cannot link a belt station Review Registration procedure Ensure units are within 1 to 3ft 0 3 to 0 9m of each other Try a Smart Purge Cannot speak over two way radio PTT not pressed Two way radio not installed to system Replacement Parts Interface cable assemblies David Clark Intercom Cable Assembly Required U3800 Vehicular Intercom System C99 22MS 40935G 08 U9800 Marine Intercom System C99 20CX 40935G 07 U9500 Marine Intercom System C99 20LL 40935G 06 U3400 Portable Intercom System U3100 Modular Intercom System C99 20MS 40935G 05 Whip Antenna P N 40688G 92 Remote Antenna Kit Mag Mount P N 40688G 93 Remote Antenna Kit Permanent P N 40688G 96 Mounting Bracket
8. olid PTT asserted Green Slow Connected pattern indicates number of belt stations connected Operation Communication All connected belt stations will be able to communicate with each other through the U9921 GUV while in range and per the VOX settings on a VOX belt station Additionally all belt station users will have communication over the intercom If the intercom is so equipped pressing the PTT button on a VOX belt station will allow the user to transmit over the system s two way radio Pressing the PTT overrides the VOX setting on a VOX belt station Multiple VOX belt station users may PTT and thus speak over the two way radio simultaneously For more information consult the user manual for the belt station Wireless users who are not pressing PTT while another wireless user is pressing PTT will not be heard on the wired intercom while the PTT remains pressed Intercom Level Adjustment Audio levels can vary between intercoms mainly due to the system level setting on the wired intercom To compensate for this the U9921 GUV has the ability to adjust its receive level from the intercom using the Vol keys see Figure 1 Pressing these keys will increase or decrease the audio level coming from the wired intercom into the gateway Perform this adjustment to obtain optimum performance Receive Level Adjustment Procedure 1 Connect at least one belt station to the U9921 GUV gateway and ensure sidetone is present see belt
9. order to successfully link This ensures that the units are not inadvertently linked with other units on the premises Linking procedure 1 2 Ensure units are within 1 to 3 ft 0 3 to 0 9m of each other Simultaneously within 1 2 sec press and release the LINK button on the U9921 GUV and the power button on the belt station to link with Amber LED s will flash on both devices A momentary red LED indicates a successful close link Upon successful link the U9921 GUV will attempt to establish a connection with the belt station Upon successfully establishing connection the LED on the controller will flash a green pattern corresponding to the number of belt stations connected Once linked the devices will not need to be linked again unless they are purged see Purging Each belt station is able to be linked to only one gateway at a time A gateway can have up to six belt stations linked and be connected to four of those six at one time Status Indications The front panel has a multi color LED in the center which serves as a status indication for the gateway Table 1 below lists these states 19541P 42 04 11 4 of 10 Table 2 LED Status Indications LED Color Blink Rate Status Red Solid Initializing power up Red Once Connection Dropped Red Once Connection Established Red Any Low battery approx 1 hr remaining Orange Slow Idle Disconnected Orange Fast Link Connection in Progress Orange S
10. station User Manual 2 Begin speaking and slowly and repeatedly press the Volume Up key on the U9921 GUV gateway until you hear an echo of your own voice 3 Continue speaking and press the Volume Down key until the echo stops 4 You may wish to verify communication with someone hard wired to the intercom 5 of 10 19541P 42 04 11 Range The range of a belt station and a gateway can be up to 300 ft 100m If you are in an environment with metal or concrete walls this range could be reduced When the belt station travels out of range of the gateway a voice alert will indicate that the connection has been lost To reconnect simply move back into range and connection with the gateway will automatically be reestablished also noted by a voice alert Purging In some circumstances it may be necessary to purge the U9921 GUV of some of its linked belt stations Typically purging is not necessary unless there are multiple gateways in the same vicinity and you wish to remove a belt station from this gateway and link to a different gateway A gateway can link up to six belt stations where a belt station can be linked to only one gateway at atime Smart Purge A smart purge is the purge method employed for the U9921 GUV in which only unwanted links are removed from the gateway When this procedure is complete only belt stations that are connected to the gateway remain linked All other belt station links will have been removed see th

Download Pdf Manuals

image

Related Search

Related Contents

netANALYZER software installation IG 01 EN  Ingersoll Rand 2475F14G Use and Care Manual  必ず2人以上で作業を行ってください。  Mode d`emploi Balance compacte KERN FCB  Sony VCT-MP1 Precautions  Samsung WB650 manual de utilizador  YOUR PO49X PIZZA OVEN CONNECTING TO POWER    MANUAL DE INSTALACIÓN  termostato programable a 7 días o 5/2 días, o no  

Copyright © All rights reserved.
Failed to retrieve file