User Manual OperationV1.1 1 Index
Contents
1. Consistence Fan 12 DC Injection Fault Device Fault GFCI Device Fault Comm Disturbed Current Sensor Fault CPU Ref 2 5V Fault Relay Fault AC Over Current ARM Ctrl Comm Fault 29 O Macsolar User Manual OperationV1 1 5 4 3 Further information for the Event Grid Voltage Fault Check the grid voltage If this event occurs The grid voltage has exceeded the permitted continuously and the inverter range according to local gird regulations doesn t work Please contact your franchiser Following conditions might lead to this error Grid voltage is out of the range rating Sudden change to the grid Grid impedance at the terminal of the inverter is too high For safety consideration the inverter will disconnect from the grid for a short time till the grid return to normal 01 Grid Overvoltage 10min Fault Check the grid voltage this event occurs The average gird voltage in 10 minutes has continuously and the exceeded the permitted range according to inverter doesn t work local gird regulations Please contact your franchiser Following condition might lead to this error Grid voltage is too high For safety consideration the inverter will disconnect from the grid for a short time till the grid return to normal 02 Grid Frequency Fault If this event occurs continuously and the The grid voltage has exceeded the permitted inverter doesn t work rang
2. If this event occurs continuously and the inverter doesn t work Please contact your franchiser If this event occurs Please check the varistors as User Manual Installation chapter 1 8 Check Varistors If this error 1s not solvable please contact your franchiser Please immediately disconnect the inverter from the PV strings see User Manual Installation chapter 2 6 DC side Disconnection Check the DC voltage of the strings for adherence to the maximum input voltage of the inverter before you reconnect the inverter to the PV strings this event occurs continuously and the inverter doesn t work Please contact your franchiser User Manual OperationV1 1 Isolation Fault Check the isolation of the PV panel The isolation resistance between the DC side If this event occurs to earth is too low continuously and the inverter doesn t work Please contact Following conditions might lead to this error your franchiser The isolation of the PV panel is not so good Internal fault of the inverter The inverter will not feed power to the grid when this event occurs DC Injection Fault If this event occurs ee i continuously and the The direct current injecting to the grid exceeds the permitted range inverter doesn t work Please contact your Following conditions might lead to this error franchiser Sudden input power change due to cloud Intern
3. If this event occurs continuously and the inverter doesn t work Please contact your franchiser If this event occurs continuously and the inverter doesn t work Please contact your franchiser O Macsolar User Manual OperationV1 1 6 RECYCLING AND DISPOSAL A WARNING ff This device SHALL NOT be disposed of in residential waste a lt To comply with European Directive 2002 96 EC on waste Electrical and Electronic Equipment and its implementation as national law electrical equipment that has reached the end of its life must be collected separately and returned to an approved recycling facility Any device that you no longer required must be returned to your dealer or you must fine an approved collection and recycling facility in your area Ignoring this EU Directive may have severe affects on the environment and your health 36 O Macsolar User Manual OperationV1 1 7 GUARANTEE SCOPE AND GUARANTEE SERVICE 7 1 7 2 Macsolar Factory Guarantee Scope This guarantee declaration is solely applied to the following Macsolar Grid Tie Solar Inverter e Macsol TL1 5K e Macsol TL2K For the above named products you will receive a Macsolar factorv warranty card which will valid for 5 vears from the date of purchase The Macsolar factorv warrantv covers any costs which you incur for repair or replacement parts during the agreed period beginning at the date of purchase of the device subject to the conditions lis
4. national and local standards and regulations Please contact your dealer to get the information of authorized repair facility for any maintenance or repairmen Any unauthorized actions including modification of product functionality of any form will affect the validation of warranty service Macsolar may deny the obligation of warranty service accordingly O Macsolar User Manual OperationV1 1 N CAUTION The PV inverter will become hot during operation please don t touch the heat sink or peripheral surface during or shortiv after operation Risk of damage due to improper modifications Never modify or manipulate the inverter or other components of the system d NOTICE Public utility only The PV inverter designed to feed AC power directly to the public utility power grid do not connect AC output of the device to any private AC equipment Macsolar User Manual OperationV1 1 Explanations of Svmbols on Inverter Svmbol Dangerous electrical voltage This device is directly connected to public grid thus all work to the inverter shall only be carried out by qualified personnel DANGER to life due to high electrical voltage There might be residual currents in inverter because of large capacitors Wait 10 MINUTES before vou remove the front lid NOTICE danger This device directly connected with electricity generators and public grid L 110min mm oct A o ES SS Danger of hot surface T
5. 2012 12 00 ARM S W a Update Time v Ver V01 00 23 02 2012 12 00 26 O Macsolar User Manual OperationV1 1 Serial Number Il 45 45 34 7 34 34 45 45 23 02 2012 12 00 Machine amp Safe MachineType 1 5K Safe Type a AS4777 23 02 2012 12 00 The above screen display information should have trivial distinctions according the different software version Display in kind practicality 27 O Macsolar User Manual OperationV1 1 5 4 FAQ Frequently asked questions When the PV plant doesn t work normally we recommend the following solutions for quick troubleshooting If there is a fault the fault LED will lights up 5 4 1 Fault level Definition According to the severity of the failure of the inverter level grades and divided into three levels respectively with A B and C while LED lights displayed in a different way to the user please refer to the following table the specific description Fault EEN Power Run Fault gra des p Green LED Yellow LED Red LED Inverter failures Stop generate power Unrepairable Unpowerable Non inverter failure Generate power Repairable Powerable Inverter failures Stop generate power Repairable Unpowerable 28 O Macsolar User Manual OperationV1 1 5 4 2 Fault logic Definition Event NO Fault Grade Grid Frequency Fault Grid Voltage Loss DC Bus Overvoltage GECI Fault Varistor Fault PV Overvoltage Consistence Fault IT NEEN me
6. Manual is to provide instructions and detailed procedures for operating maintaining and troubleshooting the following Macsolar Grid Tie Solar Inverter e Macsol TL1 5K e Macsol TL2K Please keep this manual all time available in case of emergency All the illustrated pictures in this Manual concerning Macsolar Grid Tie Solar Inverter derive from the simulated model of Macsol TL2K In the event that dimensions and parameter of products have varied please take the latest document as standard Further notification will not be issued O Macsolar User Manual OperationV1 1 1 3 Symbols Used DANGER DANGER indicates a hazardous situation which if not avoided will result in death or serious injury WARNING WARNING indicates a hazardous situation which if not avoided can result in death or serious injury or moderate injury CAUTION CAUTION indicates a hazardous condition which if not avoided can result in minor or moderate injury NOTICE NOTICE indicates a situation that can result in property damage if not avoided O Macsolar User Manual OperationV1 1 2 PREPARATION 2 1 Svstem Demonstration Solar energv generation svstems based on photovoltaic modules nowadavs represent the most suitable solution in particular for domestic power levels to reduce the energv consumption produced bv oil and gas Moreover in different European countries electricitv companies are providing monev incentives for the energv
7. Voc 25Deg C V dc Isc 25Deg C A dc Max Power 25Deg C W No of Cells in module d the MPPT number Wa Ne Ne String4 String Test Voc V JL be A l Sun Intensity When Measured High Medium jow Ne 41 O Macsolar User Manual OperationV1 1 Wiring and Connection to Grid Protective Device dc Side Type Rating A dc Rating V dc Capacitv kA dc Array Wiring Earth Polarity and Insulation Array Insulation Test Voltage Positive Earth MQ Negative Earth MQ Protective Device ac Side Rating A ac Rating V ac Capacity kA ac 42 O Macsolar User Manual OperationV1 1 PV System Installation Check List General installation Equipment compliant with standards correctly selected amp not damaged Equipment accessible for operation inspection amp maintenance Equipment and accessories correctly connected Particular protective measures for special location Equipment and protective measures appropriate to external influences System installed to prevent mutual detrimental influence Conductors connected and identified Conductors selected for current carrying capacity and voltage drop Conductors routed in safe zone or protected against mechanical damage Presence of fire barriers seals and protection against thermal effects General installation mechanical Ventilation provided behind array to prevent overheating fire risk Array frame amp material corrosion
8. produced bv renewable sources and injected into the utilitv grid Solar Panels The solar inverter 1s a critical component in a solar energy system It performs the conversion of the variable DC output of the PV modules into a clean sinusoidal 50 or 60 Hz AC current that is then applied directly to the commercial electrical grid or to a local grid electrical network Typically communications capability is included so users can monitor the inverter and report on power and operating conditions provide firmware updates and control the inverter grid connection Depending on the grid infrastructure wired RS 485 CAN Power Line Communication Ethernet or wireless Bluetooth ZigBee IEEE802 15 4 6LoWPAN networking options can be used Macsolar User Manual OperationV1 1 Safetv Instructions DANGER DANGER due to electrical shock and high voltage DO NOT touch the operating component of the inverter it might result in burning or death TO prevent risk of electric shock during installation and maintenance please make sure that all AC and DC terminals are plugged out DO NOT touch the surface of the inverter while the housing is wet it might lead to electrical shock DO NOT stay close to the instruments while there are severe weather conditions including storm lighting and etc WARNING The installation service recycling and disposal of the inverters must be performed by qualified personnel only in compliance with
9. 8kWh Total 0 16kWh 4 NOTICE LCD displav s power is for reference only and can not be used as the basis of measurement 23 02 2012 12 00 Actual value Press Left key to exit from the submenu and back to main menu Press the down key to select the Actual Value option with OK for confirmation Subsequently you have the free choice to check the actual value from the corresponding objects PV stringl or AC through operation of up and down button PV String SW 10V 0 8A 12 00 0 2 V 49 99Hz 23 02 2012 12 00 23 O Macsolar User Manual OperationV1 1 Record info Press Left key to exit from the submenu and back to main menu Press the down key to select the Record Info option with OK for confirmation You are able to check all record information generated at different moments during the running of inverter The complete record information including Record code and definition are summarized in section 5 4 2 You can also learn about the specific record description according to the corresponding event No by referring to chapter 5 4 3 Further information for the Event Record Info 22 02 2012 15 12 0 09 05 04 23 02 2012 12 00 History info Press Left key to exit from the submenu and back to main menu Press the down key to select the History Info option with OK for confirmation By virtue of the displayed graphic diagram
10. O Macsolar User Manual OperationV1 1 INDEX a A 1 i Noteson this manual tege teste eege ET ERE dn 3 LL GUuStomer NOCO peer STENE SENERE NE E ee ene eee ere 3 1 2 se EE le Eng rats EE 4 ke IN SI SE A sesreg spect enna ns sm E ERE TERE REE HERE REE EEN ES 5 a Preparati EE 6 2 1 System Demonstration D 6 Er 2 8 lo Eng re e EE 7 2 3 Explanations of Symbols on Inverter 9 2 Product Information E 10 Sal OVER a i e i a ae d ee fu ee 10 e Major Reie EEN 11 ds RT e a ii e EEEErENERE rt 12 AE ProductApped INCE ei es rer 12 4 2 Productlaentificatio b E 15 4 93 Further later Ee E 16 5 Configuration 0 0 eeceseessssssssssssesssssssssessessscssesseesscsucsseesessucssesseesssusssessussusssessuesuesuessessessuesseesessuesseeseesesseeseeases 17 Ge FENE CONN SU sacar ER sess eer cat N 17 SEENEN 18 SAT LED Bs EE 19 582 ERC 20 3a 2100 E 21 5 4 FAQ Frequently asked questions wensassicncccudssarsncctcnsadsdaseaanncdvnceasiassnoossenansiidedeaieecdsoasgucimnnadsiaans 28 SEN DR HEUTEN dng e 28 De Wait OCIS DEM o E 29 5 4 3 Further information for the Event 30 6 Recycling and Disposal iii iii tit a i a 36 7 Guarantee Scope and Guarantee Service ENEE 37 1 U Macsolar User Manual OperationV1 1 Macsolar ie eier 37 K Guarantee Ee ele CN 37 Fs Gudfamiet EXClUS Oeri E 38 G CORI E 39 9 System Commissioning Confirmation Report Een 40 lee E e e EE 46 O Macsolar User Manual OperationV1 1 1 NOTES ON THIS MANUAL 1 1 Cus
11. a mb e S Macsolar EE Bb LEDIight RUN S DS LEDight POWERO _ S O 18 O Macsolar User Manual OperationV1 1 5 2 1 LED Display The inverter is equipped with three LEDs including Green Yellow and Red which provide information about various working status Green LED The green LED lighting indicates the inverter is working normally Generally this LED begins to light up in the morning when the sunshine intensity is enough and goes out when it gets dark Yellow LED The yellow LED lighting indicates the inverter is exporting energy to grid Red LED The red LED lighting indicates the grid abnormal or the inverter abnormal and the corresponding faulty will display on LCD at the same time EXPORTING PERMANENT RESTORABLE SE ENERGY ARMI FAULT FAULT IMMA Mk 1Hz 1Hz 19 O Macsolar User Manual OperationV1 1 5 2 2 LCD Display Press any key from the control keyboard to illuminate the LCD screen Item Function Right key gt Depending on the selection Navigate right Navigate to the next level menu Down key Depending on the selection Navigate down Change to the next number Left key Depending on the selection Navigate left Navigate to the previous level menu Up key Depending on the selection Navigate up Change to the previous number OK key Depending on the selection Confirm a selection Enter the main menu lt Ee B a
12. al fault of the inverter Device Fault If this event occurs If alarm frequently and the A fault has occurred in one or more major machine cannot work 3 components of the inverter please write the feedback information form connect For safetv consideration the inverter will with supplier shutdown GFCI Device Fault If this event occurs If alarm frequently and the A fault has occurred to the GFCI detecting machine cannot work 3 circuit please write the feedback information form connect For safety consideration the inverter will with supplier shutdown Comm Disturbed If this event occurs If alarm frequently and the A fault has occurred in the internal machine cannot work 2 33 O Macsolar 8 communication of the inverter For safetv consideration the inverter will shutdown Current Sensor Fault A fault has occurred in one or more current sensor of the inverter For safetv consideration the inverter will shutdown itself CPU Ref 2 5V Fault The CPU voltage that detected by internal sensor 1s deviating the pre set 2 5V reference line EEPROM R W Fault Internal device fault For safety consideration the inverter will shutdown DC Injection Device Fault A fault has occurred to the DC current inject detecting circuit For safety consideration the inverter will shutdown Relay Fault A fault has occurred to the gri
13. ame Contractor License Number Contact Telephone Email Address 45 O Macsolar User Manual OperationV1 1 ABBREVIATION LCD Liquid Crystal Display LED Light Emitting Diode MPPT Maximum Power Point Tracking PV Photovoltaic GFCI Ground Fault Circuit Interrupter Vdc Voltage at the DC side Vac Voltage at the AC side Vmpp Voltage at the Maximum Power Point Impp Amperage at Maximum Power Point Voc Open Circuit Voltage Isc Short Circuit Current AC Alternating Current Form of electricity supplied by Utility Company DC Direct Current Form of electricity generated by PV modules VDE 0126 1 1 German standards for establishing suitability for Grid Connection of the Inverter DC Switch Switch in the DC Circuit Disconnects DC source from Inverter May be integrated or external to Inverter 46
14. d connecting relay For safety consideration the inverter will shutdown AC Over Current The detected AC current has exceeded the 34 User Manual OperationV1 1 please write the feedback information form connect with supplier If this event occurs If alarm frequently and the machine cannot work please write the feedback information form connect with supplier If this event occurs If alarm frequently and the machine cannot work please write the feedback information form connect with supplier If this event occurs If alarm frequently and the machine cannot work please write the feedback information form connect with supplier If this event occurs If alarm frequently and the machine cannot work please write the feedback information form connect with supplier Please disconnect the DC input then reconnect after a short while If this event occurs continuously and the inverter doesn t work Please contact your franchiser Check the AC network to find out the short circuit then restart the inverter manually pre set Max AC Current Following causes might lead to this error Short circuit happens in the grid ARM Ctrl Comm Fault because no communication between ARM board and Control board so the fault keeping exist Following causes might lead to this error board fall off with control board 35 User Manual OperationV1 1
15. e DC voltage of the strings to find out whether the value is in the range of specified DC voltage from datasheet If the voltage is still too high please make consultation with the system installer Otherwise please contact your franchiser Please refer to the PV system installer to renovate the ground fault this event occurs continuously and the inverter doesn t work Please contact your franchiser Please ensure sufficient ventilation O Macsolar The temperature of the heat sink is too high Following conditions might lead to this error Sensor of the temperature defective Overheating inside Not sufficient ventilation For safety consideration the inverter will disconnect from the grid until the temperature return to normal Varistor Fault The varistor on the DC side is defected Following conditions might lead to this error Varistor is burst due to high voltage surge such as thunder lightning Varistor is ageing invalid PV Overvoltage The DC input voltage which connects to the inverter is too high Following conditions might lead to this error The open circuit voltage of the PV generator is higher than the maximum DC input voltage of the inverter Sudden DC surge Junction temperature of solar panel too low Event 8 may be reported additionally Consistence Fault Internal fault has occurred for the inverter 32 User Manual OperationV1 1
16. e according to local gird regulations Please contact your Following conditions might lead to this error franchiser Grid frequency is out of the range rating Sudden change to the grid Incorrect safety guide setting For safety consideration the inverter will 30 O Macsolar disconnect from the grid for a short time till the grid return to normal 03 Grid Voltage Loss The inverter has detected an error in the cabling and cannot connect to the grid Following conditions might lead to this error Network connection installation is inappropriate Cabling inappropriate Grid power off AC output fuse open Event 0 and event 2 may be reported additionally 04 DC Bus Overvoltage The voltage of the DC Bus is too high Following conditions might lead to this error The input voltage of the PV string is too high The DC to DC function is out of control For safety consideration the inverter will disconnects itself from the grid 05 GECI Fault The inverter has detected a ground fault in the PV svstem m Inverter Overheat 31 User Manual OperationV1 1 Check AC installation Check network connection Check fuse If this event occurs If continuously and the inverter doesn t work Please contact your franchiser Please immediately disconnect the inverter from the PV strings see User Manual Installation chapter 2 6 DC side Disconnection Measure th
17. e type label example as on Macsol TL1 5K Macsolar Made in China www macsolar power com Type Macsol TL1 5K DC VDC max 480V V DC nom 360V Voempp 125 480V P oc max 1800W DC max 12A AC VAC nom 230V fAC nom 50Hz PAC nom 1500W PAC max 1650W AC nom 6 5A coso 0 99 IP 65 20 C to 60 C Protection Class Overvoltage Cat lll VDE0126 1 1 IEC62109 1 C10 11 AS4777 2 3 AS3100 G83 1 ENEL Guide RD1663 X AA ACEA WEL 86 21 68689998 E mail service macsolar power com ADD Building 9 No 590 Ruiqing Road 201201 Shanghai P R China S N 15 Macsolar User Manual OperationV1 1 Further Information If vou have anv further questions concerning the tvpe of accessories or installation please check our website www macsolar power com or contact our service hotline 16 O Macsolar User Manual OperationV1 1 5 CONFIGURATION 5 1 Fixing Complete After the inverter fixed by the engineer the display screen shows Verify that the inverter has been installed on the customer specified location DC terminal has been connected with PV AC terminal has been connected with GRID Inverter LCD operate normally When the inverter starts the RUN LED lights up after 2 seconds The inverter exports energy to grid Macsolar Power Initialize 17 O Macsolar User Manual OperationV1 1 5 2 LCD Overview mm u J
18. he components inside the inverter will release a log of heat during operation DO NOT touch aluminum housing during operating A record has occurred Please go to Chapter 5 4 3 Further information for the Event to remedy the record This device SHALL NOT be disposed of in residential waste Please go to Chapter 8 Recvcling and Disposal for proper treatments Without Transformer This inverter does not use transformer for the isolation function CE Mark Equipment with the CE mark fulfils the basic requirements of the Guideline Governing Low Voltage and Electromagnetic Compatibility Unauthorized Any unauthorized perforations or modifications are strictly forbidden if any damage device person is occurred Macsolar shall not take any responsibility for it O Macsolar User Manual OperationV1 1 3 PRODUCT INFORMATION 3 1 Overview Industrial Layout Negative Layout 10 O Macsolar User Manual OperationV1 1 3 2 Major Characteristics Macsolar inverter has following characteristics which make Macsolar inverter High Efficiency High Reliability High Cost Effective Ratio e High DC input voltage makes the inverter connect with more PV panels well e Wide MPPT voltage range makes the inverter fit in different locations and various weather conditions e High MPP tracking accuracy makes the inverter catch most of energy from panels and then converts into money to your pocket e Complete protecti
19. ide paid service Guarantee Exclusion Guarantee declaration 1s excluded in the following cases Transport damage Improper installation and installation that does not complv with standards Use of the devices in wavs not intended Improper operations without following the user manual Operation of units with defective protective equipment which might lead to damage Unauthorized modifications to the units or repair attempts Influence of foreign objects and force majeure lightning grid overvoltage severe weather fire Insufficient ventilation of the unit Failure to observe the relevant safetv regulations If the device becomes defective in any of the above cases Macsolar will not perform guarantee service and the user shall take all the responsibilitv for the defects 38 O Macsolar User Manual OperationV1 1 8 CONTACT Shanghai Headquarter Building 9 No 590 Ruiqing Road CN 201201 Shanghai P R China Email info macsolar power com www macsolar power com Serviceline Email service 0 macsolar power com www macsolar power com 39 O Macsolar User Manual OperationV1 1 9 SYSTEM COMMISSIONING CONFIRMATION REPORT This report confirms successful commissioning of a Photovoltaic Inverter System connected to the public electricity distribution network This after installed Commissioning Sheet must be returned to the Authorized Distributor to activate any and all inverter warranty Failure to return this Comm
20. issioning Report may void all inverter warranty Site Details Contact Details Macsolar Inverter Details aa i p aaa aa aa za TM aa ANN zz Inverter Model Inverter Serial Number Software Version Numbers kontrol Sofware b Display Software 000 Inverter RatingikW i d Number of Inverter MPPT Inputs 0 p Installation appropriate box Outside Under Array 1 Outside Exposed to Weather Outside Under Cover o o o Inside Building AG ke ere Location of dc array isolator sO 40 O Macsolar User Manual OperationV1 1 Installed Photovoltaic Modules Array String 1 2 3 4 Number Of Modules String III String 1 Module Details O O Z 0O O MPPT Input JY the MPPT number IT MMM Module Nominal Power Wp ECC Voc B 25Deg C V do Isc 25Deg C A dc Max Power 25Deg C W No of Cells in module String 2 Module Details MPPT Input Module Brand and Type Module Nominal Power Wp Voc 25Deg C V dc Isc 25Deg C A dc Max Power 25Deg C W No of Cells in module d the MPPT number String 3 Module Details MPPT Input Module Brand and Type Module Nominal Power Wp Voc 25Deg C V dc Isc 25Deg C A dc Max Power 25Deg C W No of Cells in module d the MPPT number l String 4 Module Details MPPT Input Module Brand and Tvpe Module Nominal Power Wp
21. lt gt NOTICE Macsolar inverter is not an aligned measuring instrument for current voltage or power consumption A slight deviation of a few percent points is intrinsic to the system the results from the inverter cannot be used for grid balance calculations An aligned meter will be required to make calculations for the utility company 20 O Macsolar User Manual OperationV1 1 f NOTICE Make sure the DC switch ON otherwise Macsolar inverter cannot work due to the power shortage Display After the inverter has started programs will be initialized with the screen showing as follows Macsolar Power Farre 23 02 2012 12 00 21 O Macsolar User Manual OperationV1 1 Now in this interface you can check all necessary information about the system Macsolar Power Pac xx iW Fgrid x xHz V grid xx 25 02 2012 12 00 After reviewing all information relevant to the svstem vou are able to enter the main menu by pressing the OK button on display panel and acquire any parameter concerning the product which interests you such as yield power record info etc Macsolar Power p Yield Power Actual Value Record Into History Data Configuration Device Into 23 02 2012 12 00 Yield Power Select Yield Power option to enter the submenu and the cumulated power generation by Day will be presented on the screen ZL O Macsolar User Manual OperationV1 1 Yield Power Today 0 0
22. on methods setting Also following protection methods are integrated in Macsolar inverter s Internalovervoltage e DC insulation monitoring e Ground fault protection e Grid monitoring e Ground fault current monitoring e DC current Injection monitoring 11 O Macsolar User Manual OperationV1 1 A UNPACKING 4 1 Product Appearance Front A RUN O Macsolar e RAULT FAULT Sc OK B LEDIight RUN S O D IEDlight POWER _ _ _ _ gt S O 12 User Manual OperationV1 1 Bottom PVI PV2 I pvl I pv2 Max Input Current U pvl U pv2 Absolute DC Voltage Object Description DC input 1 set for Macsol TL1 5K and 2 sets for Macsol TL2K Anode 13 O Macsolar User Manual OperationV1 1 connected with anode cathode connected with cathode PV1 Input Current PV2 Input Current Max Input Current PVI Voltage PV2 Voltage Absolute DC Voltage Plugs for connecting the RS485 communication module Among them COMI must be equipped but COM2 is an optional Customized using for connect with the inverters D connection Optional 14 Macsolar User Manual OperationV1 1 Product Identification You can identify the inverter by the side type label Information such as serial number SN type of the inverter as well as inverter specifications are specified on the side type label The type label is on the middle part of the right side of the inverter housing Sid
23. proof Array frame correctly fixed and stable Roof fixings weatherproof Cable entry weatherproof Protection against overvoltage electric shock Live parts insulated protected by barrier enclosure placed out of reach or Class II Array frame equipotential bonding present only relevant if required Surge protection devices present only relevant if required RCD provided only relevant if required Frame correctly integrated with existing LPS installation ystem Physical separation of ac and de cables Dc switch disconnect fitted Dc cables protective and reinforced insulation only relevant if required All dc components rated for operation at max dc system voltage Voc stc x 1 25 PV strings fused or blocking diodes fitted only relevant if required AC System Ac isolator lockable in off position only Inverter protection settings to local regulations ling amp identification General labeling of circuits protective devices switches and terminals PV system schematic displayed on site Protection setting amp installer details displayed on site Emergency shutdown procedure displayed on site Ac isolator clearly labeled Ac isolator junction boxes suitably labeled Signs amp labels suitably affixed and durable E REAHEkK EI EH BE Te E OOOO z 00o0o0q LI LILILILI La OOOOOOOFOO 43 O Macsolar User Manual OperationV1 1 Comments Separate Page if Necessary 44 O Macsolar User Manual OperationV1 1 Installer Company N
24. ted below This is not associated with a durabilitv warranty Xou have the possibilitv of purchasing an extension of this Macsolar factorv warrantv within the 5 vear term of the Macsolar factorv warrantv The prices are based on the respective Macsolar price list valid at the time the warrantv extension was signed Guarantee Conditions This guarantv declaration is solelv applied when anv defect of Macsolar inverter is detected If a device defected during the Macsolar guarantv period and it is proved that further functional performance 1s impossible the device will be as selected bv Macsolar e Repair the defect at the factory within the guaranty period e Replace a be selected device of equivalent value according to model and age If it is the latter case the remainder of the warranty entitlement will be automatically transferred to the replacement device In this case you will not receive a new certificate since your entitlement is already documented at Macsolar 37 7 3 User Manual OperationV1 1 NOTICE If replace a device of equivalent value according to model and age is needed The defected unit must if possible be returned with its original or equivalent packaging Macsolar will only perform guarantee service when the user provides a copy of invoice which was issued to the user by the dealer and a completed warranty card If either of then missing Macsolar has the right to deny the guarantee service or only prov
25. tomer Notice Please before using the inverter check the fixing engineer using PV groupware like electricity voltage power are suit for the product specification and it the fittings belong to the setting box If the inverter cannot work normally because of the problems below it s not the quality problem and our company will not take any responsibility the problems are follows the inverter damaged because larger PV electricity and voltage which cause the inverter cannot be operated the inverter damaged because didn t use our company s DC and AC terminals Inverter fixing angle not consistent not fixing according to the specification for example lie low hang back buckle back Inverter damaged during inverter fixing process 43 NOTICE After purchase this product please return the guarantee slip and One Commissioning Sheet per installation by mail company or by taking pictures of the electric upload photos to the company s Web site are effective in two ways when our company receive guarantee slip and One Commissioning Sheet per installation our company can supply the services for the customer otherwise the company will not take any responsibility Address Building 9 No 590 Ruiqing Road Pudong 201201 Shanghai P R China Consignee SHANGHAI MACSOLAR POWER CO LTD website www macsolar power com O Macsolar User Manual OperationV1 1 1 2 Scope of Validation The main purpose of this User s
26. you can check the power generation in last 7 days 23 4 5 6 23 02 2012 12 00 24 O Macsolar User Manual OperationV1 1 Configuration Press Left button to exit from the submenu and back to main menu Press the down key to select the Configuration option with OK for confirmation Subsequently you are eligible to set up the Language Date Time Address Safe Type through manipulation of up and down button Language Setup Set Language gt English 23 02 2012 12 00 Date Time Setup Use Up Down key to set the number and confirm the settings by OK button Set Date amp Time 23 02 2012 aa lee 23 02 2012 12 00 Address Setup Use Up Down key to set the number and confirm the settings by OK button NOTICE Possible communication failure due to wrong configuration Selection of the inverter s address will directly affect the performance of the data logger 25 O Macsolar User Manual OperationV1 1 Set Address 240 1 255 23 02 2012 12 00 Device info Press Left key to exit from the submenu and back to main menu Press the down key to select the Device Info option with OK for confirmation Then you can get access to system information involving control software ARM software serial number machine type and safety type Control S W Update Time vo Ver V01 00 23 02