Home
JVA SMS Gateway User Manual
Contents
1. Model Energiser model eg Z14 ZM20 ID Keypad bus device ID 1 15 V1 V2 Primary voltages usually feed and return in kV Alarms CommsFail OR FenceAlarm1 FenceAlarm2 AcFail LowBatt BadBatt Tamper Fault GateAlarm OR No Alarms The hardware status of the unit can also be requested by issuing a gsm command The unit will reply with signal strength the last system start date and time as stored in memory and the firmware version Report List The unit can store up to 9 phone number which it will SMS if a device goes into alarm or an input changes This list is configured and maintained using the add and remove commands You can retrieve the current list of numbers using the numbers command Issuing an add command followed by a valid number will add the number to the report list It is possible to add duplicate numbers to the list which will result in that number receiving multiple SMSes each time an SMS is broadcast Numbers can be in either the Page 6 JVA SMS Gateway User Manual national format eg 0412 345 6789 or international dialling format eg 61 412 345 6789 After successfully adding a number the unit will reply with the report list and an SMS will be sent to the new number informing them they were added Numbers can be removed by issuing the remove command followed either by the number or the position of the number in the report list If entering a number it must be in the same format as
2. www jva fence com au VA SMS Gateway User Manual PTE0319 JVA SMS Gateway User Manual Introduction The PTE0319 JVA SMS Gateway enables a group of JVA Z Series energisers to be controlled and monitored by SMS from anywhere in the world With a phone call or short SMS users can obtain an up to date status report of all their energisers turn on arm or off disarm all the energisers at once as well as switch handy output relays for custom applications This unit can store up to 9 phone numbers If an energiser goes into alarm or one of two inputs are triggered an SMS will be automatically generated and sent to each stored number Designed with ease of use in mind the system does not have an endless list of configuration options or complex methods of set up All configuration is via SMS to the unit secured with a user definable PIN The JVA SMS Gateway communicates on the widely supported and robust GSM mobile phone network and will work in any country with 2G coverage Simply insert a valid topped up SIM card from your preferred carrier and you are ready to remotely control and monitor your energisers from anywhere in the world Features e Works with entire JVA Z range of energisers as well as the ZM1 and ZM20 monitors e Can monitor and control up to 15 devices linked via Keypad bus as well as two dry contact inputs and two 30Vdc 8A relays e Produces an up to date status report including arm state alarms an
3. of the case by gently lifting the side clips Unclip the top of the circuit board to remove from the case back Mount the case back using suitable screws Be sure the screw head will not contact the PCB when it is re installed The unit must be mounted indoors or in a suitable enclosure to protect it from moisture It is NOT water proof and damage due to moisture is not covered by the warranty Obtain a suitable SIM card Activate it according to the instructions either via the internet or by phone and make sure it has credit available Insert the SIM card into a mobile phone and confirm you can receive calls and send SMSes Remove the SIM card from the phone and insert into the unit contact side down with the notched corner to the lower right Clip the circuit board into the case back Connect the antenna Mount the antenna away from high voltage and mains power cables vertically if possible If the unit is housed in a metal enclosure the antenna should be mounted outside the enclosure and the enclosure earthed Connect 12V Data and Ground wires from the unit to a JVA energiser Power on the energiser The unit should also power on Confirm the GSM light flashes briefly once every 2 seconds and that the STATUS light flashes approximately every second Clip the case front back on Your JVA SMS Gateway is ready to use Operation SMS Commands The unit is controlled and configured by SMS All commands are of the format PIN command para
4. 5678 remove lt index gt Removes the 1234 remove 1 1 61412345678 or r lt index gt number atthe given 1234r2 Number not found index from the report list in report list remove lt number gt or r lt number gt Removes the specified number from the report list 1234 remove 041 234 5678 Number not found in report list 1234 r 61 41 234 5678 Report list is empty gsm Requests GSM status 1234 gsm Signal 25 System org up 13 56 2015 06 10 Fw 1v3 0 status Requests 1234 status Z14 1 On 6 8kV ors energiser monitor 1234 s 6 4kV No alarms or primary voltages 1234 ZM20 2 Off arm and alarm state LowBatt and unit input and In1 Off In2 Off Out1 output state On Out2 Off help Requests a 1234 help This table in 160 or h command summary 1234h characters 1234 on Arms all devices 1234 on Energiser s are on orarm off Disarms all devices 1234 off Energiser s are off or disarm Page 9 JVA SMS Gateway User Manual Command Description Example Response output1 lt on off gt Controls relay 1 or 2 1234 output1 on Output 1 is now on or out1 lt on off gt 1234 1 off Output 1 is now off or 1 lt on off gt or aux lt on off gt output2 lt on off gt or out2 lt on off gt or 2 lt on off gt or gate lt on off gt 1234 out2 on Output 2 is now on 1234 gate off Output 2 is now off Troubleshooting The JVA SMS
5. Gateway is designed to work straight out of the box with little set up or configuration The only crucial step is to ensure the unit has good mobile reception and an activated SIM card with credit Refer to the troubleshooting table below for more information Fault Likely Cause Remedy No lights are on Power is not connected Power wires are reversed Check power connections Check voltage at power connections with a multimeter GSM light is on not flashing SIM card not activated Confirm SIM is activated by inserting into a mobile phone and sending and receiving texts Poor signal strength Check antenna connection Move antenna mounting place GSM light flashes fast and continuously Software corruption Contact your nearest JVA distributor Status light not flashing Keypad bus is not connected Check the keypad bus DATA and GND connections Energiser malfunction Confirm a JVA keypad can control the energiser using the same connections Group configured incorrectly If there is more than one energiser ensure one is configured as master device ID 1 and the others have unique device IDs of 2 or more Page 10 JVA SMS Gateway User Manual Fault Likely Cause Remedy Unit does not reply to phone calls with a status message Caller ID information blocked Use the same phone to call another number and confirm your number appears o
6. d primary voltages of each device and input and output states e Responds to status request by SMS or missed call e Can store up to 9 phone numbers to be notified if a device goes into alarm or one of two inputs are triggered e All commands secured by user configurable PIN e Easily configurable by SMS e Compatible with the all types of JVA Keypad and with Perimeter Patrol Page 1 JVA SMS Gateway User Manual Specifications Power supply 12VDC1A Inputs Dry contact or active pull down Outputs 30Vdc 8A SPDT SIM Micro Antenna connector Female SMA Overview cio WN pe PC211 PAESIB GSM JVO1 C JUA 2015 GSM Antenna LED Status LED Poll LED Fire LED GSM Input trigger1 TVOG f Ground Input trigger 2 Data Gate motor Auxiliary oe relay Page 2 JVA SMS Gateway User Manual LED Indicators GSM On no flash If there is a problem with the antenna or SIM card the LED will remain on indicating the unit is not connected to the GSM network Slow flash GSM network connected Very fast flash The unit has corrupted software STATUS Blinks when the unit receives a status message from the group POLL Blink when the unit is sending a command to the group or requesting additional information FIRE Not used Inputs Two dry contact inputs are provided If the unit sees a short circuit between the input terminals it will register the input as being On Just lik
7. e the inputs on all JVA Z series devices the input can also be asserted from an electrical source by driving the right most terminal to ground Outputs Two SPDT relays are available as general purpose outputs These relays can switch DC voltage up to 30V and 8A The outputs can be switched on or off by SMS and are ideal for connection to external lights pumps electric motors gate openers or interfacing to an existing alarm or control system Antenna A GSM antenna is supplied with the unit and must be connected to the unit for it to communicate on the mobile network If mobile reception in the area is particularly weak the antenna can be substituted for a more powerful one provided it has a male SMA connector Ensure the antenna is mounted away from any high voltage cables or AC power cables which could cause interference If the unit is mounted inside a metal enclosure the antenna should be mounted external to the enclosure and the cable entry hole be sealed against water ingress Page 3 JVA SMS Gateway User Manual Power and Keypad Bus The keypad bus enables digital communication between the SMS Gateway and connected devices Connect the DATA and GND terminals to the equivalent terminals of all connected devices The SMS Gateway requires 12V dc to operate This power may be supplied from the keypad bus of a connected energiser or for best results a separate 12V 1A power supply may be used Do not connect the unit to a s
8. eparate power supply and keypad bus 12V of an energiser at the same time The SMS Gateway operates as a keypad with keypad ID 2 Keypad ID 3 is reserved If other keypads or keypad devices such as the PAE212 or Perimeter Patrol are to be used with the group they should be set to keypad ID 1 4 or greater SIM card The SMS Gateway requires a Micro SIM card that is activated and has credit The SIM card should first be tested in a phone to ensure it can send and receive text messages and also receive phone calls Insert the sim card with the cut corner to the bottom right unclipping the PCB from the enclosure temporarily if required Connect the antenna and power and confirm the green GSM LED flashes every 2 seconds If the LED stays on without flashing the unit cannot connect to the network indicating a problem with the SIM card or antenna A good value pre or post paid plan should be chosen for the SIM card The unit does not use data or voice calls only SMSes Estimate how many SMSes are likely to be generated per day If the unit is queried for status often a plan offering unlimited SMSes may be good value keeping in mind the ongoing cost will mostly likely be monthly If the unit is unlikely to generate a SMS in normal operation and is only for emergencies plans offering more expensive SMSes but longer credit expiry periods are also available Page 4 JVA SMS Gateway User Manual Installation Detach the front
9. gies Pty Ltd
10. he GSM light is flashing once every 2 seconds issue a status command 1234s The unit will reply with a summary of all connected energisers Next add your number to the report list For example if your phone number was 0412 345 6789 send 1234 a 04123456789 The unit will reply with 1 04123456789 indicating there is one number on the report list yours Now try arming you energiser s by sending 1234 on You should see the energiser s arm and receive an sms saying Energiser s are on Now disarm the energiser s by sending 1234 off You will see the energiser s disarm and receive another confirmation text Fora complete list of commands refer to the section Command Summary Page 8 JVA SMS Gateway User Manual Command Summary The table below summarises all available SMS commands The default PIN is used in examples but you should replace this with your own PIN if it has been changed Command Description Example Response changepin lt PIN gt Changes the PIN 1234 changepin 4321 PIN is now 4321 or c lt PIN gt 4321 c 1234 PIN is now 1234 1234 c 123 Invalid PIN add lt number gt or a lt number gt Adds the specified number to the report list 1234 add 041 234 5678 1 0412345678 1234a 61 41 234 1 0412345678 5678 2 61412345678 1234 a 555JVAROCKS Invalid phone number numbers Requests the report 1234 numbers 1 0412345678 orn list 1234 n 2 6141234
11. it is stored in the list After successfully removing a number the unit will reply with the report list and an SMS will be sent to the removed number informing them they were removed Controlling Energisers and Outputs The unit can turn all energisers on arm or off disarm by issuing the on or off command When arming the unit will arm in high power only and arm both channels of any dual channel energisers When the unit has confirmed the new arm state it will reply to the sender with a confirmation message The unit has two relays than can be turned on or off Issue an output1 or output2 command with the parameter on or off Note there is no space between output and the number 1 or 2 The unit will reply with a confirmation message Alerting users of alarms The unit monitors the connected energisers and will send a SMS to everyone on the report list if the following things occur e A fence alarm occurs usually due to a short on the fence e Anenergiser stops communicating e An input changes If multiple energisers report changes at the same time the unit will send one SMS for each change Page 7 JVA SMS Gateway User Manual Basic Commands The following is the minimum commands you will need to know to get your JVA SMS Gateway working It assumes the PIN is still set to the default of 1234 When you have installed and powered on your unit for the first time the connected energiser s are powered on and t
12. meter with spaces separating each part The commands and parameters are not case sensitive Many commands may be replaced with only their first letter A help message can be requested by issuing the help command The unit will reply with a summarised list of available commands PIN All commands are prefixed by a PIN number to secure the unit against unauthorised changes The PIN must be between 4 and 12 digits long The default PIN is 1234 The Page 5 JVA SMS Gateway User Manual PIN can be changed by issuing a changepin command with the new PIN as the parameter If successful the unit will reply and inform everyone on the report list of the new PIN If you forget the PIN a factory reset must be performed See the section Factory Reset for more information Querying the Status The SMS Gateway can be queried to return the status of the inputs outputs and all Z series devices connected to it via the Keypad Bus Simply issue a status command or alternatively call the unit It will detect your call and hang up after two rings then SMS you with a complete status For this to function it is important your Caller ID information is not blocked otherwise the unit will not know which number to send the reply to The SMS will take the format Model ID lt On V1 V2 or Off gt lt Alarms gt Model ID lt On V1 V2 or Off gt lt Alarms gt In1 lt on off gt In2 lt on off gt Out1 lt on off gt Out2 lt on off gt
13. n their phone Check phone settings for Caller ID blocking Unit does not control energisers Another keypad or keypad device is connected with keypad ID 2 Disconnect the other keypad or change its ID to 1 4 or greater Unit responds to SMS commands but does not reply Insufficient or expired credit Check the SIM card has credit available If the unit is still not working correctly contact your nearest JVA distributor for technical support Page 11 JVA SMS Gateway User Manual Support Factory Reset If the PIN has been changed from its default setting and has been forgotten the unit will need to be factory reset Confirm the unit has signal and the SIM card has credit by issuing the command 1234 g and awaiting the reply Incorrect PIN Contact your nearest JVA distributor with the mobile phone number of the SIM card and they will remotely reset the unit for you JVA Distributors If you have any questions or need further assistance please email us at sales jva fence com au or phone one of the numbers listed below Region Number Australia 07 3103 0582 South Africa 0861 782 349 World Wide 61 7 3103 0582 For more information on our complete range of electric fencing products please see the JVA website www jva fence com au Page 12 JVA 2015 Manufactured for JVA by Pakton Technologies The JVA logo is a trademark of JVA Technolo
Download Pdf Manuals