1. EXCELLENCE User Manual SE 400 We congratulate you for choosing Sauber Excellence the first class cleaning system Before operating the Sauber Excellence please read this instruction manual carefully and keep it for future reference auher Its German for clean sauber EXCELLENCE SE 400 sauber EXCELLENCE SE 400 s oatety Instructions IMPORTANT Always switch off the cleaner and remove the plug from the electricity power supply before cleaning your appliance when not in use or attempting any maintenance task The cleaner must only be connected to an AC power supply at the voltage shown on the rating label This cleaner should only be used for its intended purpose as described in this instruction manual Never operate the vacuum cleaner without filters When using your vacuum cleaner basic precautions should always be observed including the following e This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance To prevent electrical shock do not immerse the appliance power cord or power plug into water or other liquids e o prevent electrical shock do not use the vacuum cleaner outdoors o
2. Powerclean Sauber Excellence will guarantee a deep efficient cleaning brush is operating Keep The VACUFLEX high flexibility makes use of the Powerclean moving the nozzle to brush light and simple avoid wearing of the fabric x MM gt Lie Cleaning without VACUFLEX a uten Remove VACUFLEX to clean stairs and small carpet areas This application requires air flow in order to allow dust pick up owitch on off the Powerclean brush by pressing on the brush button on the electronic control handle VACUFLEX VACUFLEX is a patented flexible bottom plate for deep cleaning Removal of VACUFLEX IMPORTANT Always turn off the vacuum before making any adjustment to the Powerclean brush To remove VACUFLEX hold the plate at one side edge With little force turn it down over the small side ramp The locking of the plate will lift and automatically release itself Important Information The Powerclean brush PL1 has been designed for small surfaces max 6m and is not suitable for big carpet areas or carpeted floors The Powerclean brush PL 1 should not be used to clean leather or similar material It is not advised to use the Powerclean brush PL1 on curtains and other hanging canvas sauber EXCELLENCE SE 400 sauber EXCELLENCE SE 400 Accessories HL1 Maintenance Use the small combination nozzle on the brush side for dusting N Danger and Live Parts Within Always unplu
3. filter in the HEPA 1 H13 filter frame Make sure that the filters are correctly in place Lock the HEPA 1 H13 filter handle in position Replace the dust bag and close the front lid The long term HEPA 2 filter lasts some years with regular use before it needs replacing The warranty may be void if ORIGINAL Sauber bags and filters are not used m ze EXCELLENCE SE 400 Asthma Foundation s NZ Sensitive Choice program On the basis of its exclusive five stage medi clean filtration system dust in indoor air sauber EXCELLENCE SE 400 air hygiene test according to TUV NORD standards for house dust and indoor allergen retention ET Technical Data Nominal power consumption 120W Voltage 240V 50Hz Brush width 310mm Brush Speed 2700rpm PL1 Technical Data Dimensions 28 x 19 x 9cm Weight 532gm Brush width 15cm Power Consumption 20W Voltage 240V 50Hz 3 23 EU amended by 93 68 EU Double insulation EI CE complies with the EU directive for CE certification Safety in accordance with 69 336 EU amended by 91 263 EU 92 31 EU and 93 68 EU 73 23 EU amended by 93 68 EU Parts and Accessories Product Name Product Code Dust Bags 4 Pack 3244 0274 Dust Bags 20 Pack 3242 0356 Long lerm Filter 3220 0718 HEPA 1 H13 Filter and Carbon Filter Kit 3220 0719 Bag and Filter Kit 3230 0004 includes 8 dust bags HEPA 1 H13 filter and carbon filter Heplacement Belt 32100172 Cu
4. foot pedal ON OFF foot pedal E EI Ea Aroma compartment not shown Powered hose M Electronic control handle N Telescopic tube ET1 Powerclean head P omall combination tool KA Radiator brush Li Crevice tool s PL1 Powerclean brush Automatic floor head EJLI EI EI EJ Turbo Clean optional accessory m QD GE E i ner EXCELLENCE SE 4505 sold separately sauber EXCELLENCE SE 400 Assembly The cleaner should be switched off and disconnected from the mains power supply before you start to assemble Before You Begin amp amp 8 G9 C9 Do not operate the vacuum cleaner too close to heaters radiators and other hot surfaces 2 Before inserting the plug into the wall make sure your hand is dry Before turning on the vacuum cleaner remove any large or sharp objects from the floor or cleaning surface in order to prevent damage to the filter 4 When you want to pull the plug from the wall do not use the power cable gently pull the plug from the power socket 5 If the air inlet floor head or telescopic tube are blocked you should switch off the cleaner straight away and remove from mains power supply First clear the blocked substance before attempting to start the vacuum cleaner again Please do not expose the electrical hose to water or clean it with water Damaged cables should be inspected by an authorized Sauber service representative Do not use the
5. machine with damaged cables Important instructions for use of a powerhead Leaving the machine in a stationary position for an extended period of time while the brush roller is spinning may cause damage to your floor or carpet Be sure not to allow carpet edges or fringe into the brush As with any vacuum with a rotating brush this machine could cause damage to loosely woven carpets or rugs wool loop carpets long piled carpets or very soft sensitive floor coverings Please use the combination head for the above mentioned floorings We do not recommend the use of the powerhead for cleaning old and especially valuable hand crafted carpets If you have uneven flooring the metal part underneath the machine may come in contact with the floor causing scratches Please carry the machine across high thresholds WARNING DRY USE ONLY Do not use in wet conditions sauber EXCELLENCE SE 400 Open the shutter and gently push the powered hose in the opening Connect the telescopic tube to the Powerclean head ET1 Gently pull out the power cable and connect it to the power socket owitch on off the Powerclean head by pressing on the brush button on the electronic control handle sauber EXCELLENCE SE 400 Connect the electronic control handle to the telescopic tube To extend the length of the telescopic tube Slide the lock down To reduce the extension slide the lock up Switch on the vacuum clea
6. mediclean connection Use the buttons on the vacuum cleaner as the rer i m Idem 2 yntnetic dus ag ong ierm handle buttons do not work when using the blowing function Filtration of rough Filter particles Filtration of micro particles filtration of the motor carbon dust with anti bacteria treatment filtration of germs and bacteria E Use the blowing function to dry shoes Pe NT re et mediclean mediclean ei I bh D HEPA1 H13 filter Paved activated Carbon Filter Filtration of micro particles Filtration of gas and odours This symbol on the product or on its packaging indicates that this product may not be treated as household waste Instead it shall be handed over to a Sauber service or collection point for the recycling of electrical and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment and human health which could After usa otherwise be caused by inappropriate waste handling of this product owitch off the vacuum cleaner unplug the power cable and press on the cable winder foot pedal to retract the power cable Motor overheating cool down for 30 45 mins If the symbol appears again contact the closest Sauber JA Always store your Sauber Excellence as indicated in the picture in a cool dry place Replace the dust bag t Change HEPA 1 H13 Service centre and Carbon filter NO HEPA 1 H13 in
7. place Powerclean brush or Powerclean head ON AUTO function ON Intelligent Power Control IPC mode Power indication is sess EXCELLENCE SE 400 EXCELLENCE SE 400 Heplacement of consumables Dust bag and filters Technical Data Double insulation E CE conforms to the EU directive for CE certification Open the front lid by pressing on the opposite locking button Safety approved according to IEC335 1 and 335 2 2 Dimensions 57 5 x 25 x 23 5cm Weight 6 7kg Maximum power consumption 1250W Maximum motor power consumption 1200W oupply voltage 240v 50Hz Noise level vacuum cleaner 65 dBa Operating radius 12 5m To change the dust bag take it out by the handle dispose of it and replace it with a new bag If the dust bag is not in place the lid will not close oauber Excellence is recommended by the Service Allergy Suisse as a result of scientific tests run by the independent institutes T V NORD and GUI To change the HEPA 1 H13 and the carbon filter unlock the HEPA 1 H13 filter handle in the upright position and pull out the filters TESTED amp RECOMMENDED BY EXPERTS Pm Dispose of them e T 7 pagsa swiss allergy service ch Scientifically tested Suitable for people National Asthma by AHA Swiss and demonstrated to with allergies Passed Approved by the Recommended Council Australia and Allergy Centre effectively reduce fine a voluntary indoor Click the carbon
8. present e Do not use the appliance to pick up toxic materials i e chlorine bleach ammonia e Ensure the appliance is disconnected from the mains power supply before connecting the hose to the unit a AE EXCELLENCE SE 400 e Do not operate or use the appliance without the dust bag and or filters in place e Before vacuuming remove any large or sharp objects from the floor or cleaning surface in order to prevent damage to the filter If the air inlet floor head or the telescopic tube is blocked switch off the cleaner straight away and remove from the mains power First clear the blocked object before attempting to start the vacuum cleaner again Hold the plug when rewinding onto the cord reel To prevent accidental injury do not allow the plug to whip when rewinding Do not extend the power cable beyond the yellow mark Do not leave the appliance unattended when it is connected to a mains power supply Before carry out any maintenance service or cleaning the filters always switch off the vacuum cleaner and disconnect the plug from mains power supply Keep ends of the hose telescopic tube and other openings away from your face and body Do not use the vacuum cleaner if it is damaged or breaks down Check the electrical regularly for defects If connection cables electrical hoses electrical contacts and electric tubes are damaged have them replaced immediately Never clean the vacuum cleaner
9. g the vacuum from mains power supply before dismantling any part of the machine The vacuum cleaner Powerclean brush contains electrical connections The vacuum cleaner Powerclean brush is not a serviceable part Cleaning the brush If threads and other matter gets caught in the brush roll remove the VACUFLEX carefully cut along the cutting groove of the roller being careful not to damage the brush then turn on the vacuum cleaner to suck in the loose threads The Powerclean brush can be wiped clean with a damp cloth Use the combination nozzle on the wing side to vacuum upholstery The small combination nozzle can always be kept at hand by placing it on the handle support When vacuuming curtains reduce the vacuum power manually Automatic switch off function If the Powerclean brush is blocked the motor switches off automatically If this occurs switch off the vacuum cleaner remove whatever item has blocked the Powerclean brush and switch on again If the Powerclean brush does not start again after cleaning contact your local Sauber service centre Use the crevice nozzle when vacuuming narrow spaces such as corners and grooves Place the radiator brush on the crevice nozzle sauber EXCELLENCE SE 400 s EXCELLENCE SE 400 Sauber Aesicker a world revolution in healthy cleaning Blowing function Open the lid and push the powered hose into the blow port Pe E ee E mediclean
10. he AUTO button In this mode the Automatic floor head will adapt to the surface it is vacuuming by lifting and lowering the brush automatically For short breaks insert the nozzle in the side parking position the motor will then stop running If the break is longer than 5 minutes the Sauber Excellence will turn off automatically for safety reasons sauber EXCELLENCE SE 400 the back as indicated on the Automatic floor head To manually set the hard floor function Slide the button towards the front as indicated on the Automatic floor head E 1 Powerclean Head Carpets only keep their appearance when brushed thoroughly during vacuuming Powerhead oelecting the Correct Brush Height 2 Brush height adjustment Swivel neck a Connection plug BH Release button m Brush indicator light red Power light green B Brush roller cover m Brush roller release button Foot Pedal Access door Operating Instructions The use of a powerhead is recommended for the optimal cleaning of carpets The rotating design of the swivel neck 3 allows the powerhead to move in any direction making it easy to manoeuvre around obstacles The powerhead also has an adjustable brush height and to the edge brush action for effective all round cleaning By pushing the foot pedal 10 and lowering the handle you activate the powerhead and the brush begins spinning Failure to
11. ner from the electronic control handle or from the vacuum cleaner Operation IMPORTANT Before using unwind a sufficient length of cable and insert the plug into the power socket A yellow mark on the power cable shows the ideal cable length Don t extend the cable beyond the yellow mark From the electronic control handle Operation IMPORTANT Before using unwind a sufficient length of cable and insert the plug into the power socket A yellow mark on the power cable shows the ideal cable length Don t extend the cable beyond the yellow mark From the vacuum cleaner To start the vacuum cleaner press the ON OFF foot pedal The vacuum cleaner will start in Intelligent Power Control IPC mode To switch off the vacuum cleaner To start the vacuum cleaner press on the AUTO button The vacuum cleaner will start in the Intelligent Power Control IPC mode To change to manual mode press the buttons To manually To return to the press the ON OFF increase or Intelligent Power foot pedal bir B a vox mode Set the Automatic To manually set the posee pigs Nee floor head on the carpet function slide the or button mode press once on AUTO function ihe buton towards Press the brush button to turn ON OFF the Powerclean head or Powerclean brush e AS EXCELLENCE SE 400 the AUTO button To turn off the vacuum cleaner in the Intelligent Power Control IPC mode press once on t
12. ong the life of accessories and consumables regular care and maintenance is recommended When properly used and cared for your cleaner will render excellent service refer to the instruction manual for further details as misuse or failure to follow the instructions makes this warranty void In the event of service or advice being needed please contact Sauber Customer Service Level 1 Building 2 Brandon Business Park 530 Springvale Road Glen Waverley Vic 3150 or on 1800 728 237 Monday Friday 9am 5pm EST The decision to repair or replace the cleaner is at the sole discretion of Sauber If Sauber decide to repair or replace the cleaner it will do so at its own cost Sauber is unable to accept responsibility under this warranty for any repair work not carried out by an authorised Sauber Service Agent or from the use of non genuine parts If any part is no longer available or manufactured Sauber will replace it with a genuine functional replacement part This warranty does not apply to the cost of replacing any parts of the product due to normal wear and tear alterations improper installation physical abuse misuse or accidental damage Any transportation costs involved in the repair of defective parts shall be borne by the claimant If proof of purchase cannot be provided at the time of a warranty claim or service any work carried out on the cleaner is chargeable The repair or replacement of the cleaner unde
13. or any of the electrical parts especially the electrical connections with water or liquid cleaners e Never attempt to make any modifications electrically to the vacuum cleaner e Always store the appliance indoors in a cool and dry place e Do not pickup water dry household use only e Damage caused by improper use or by not observing the instructions in this manual will void warranty El1 and PL1 Safety Instructions e The electric hose contains electrical connections Do not immerse it in water for cleaning The hose should be checked regularly and must not be used if damaged The vacuum cleaner handle contains electrical connections the handle is not a serviceable part The vacuum cleaner rod contains electrical connections the rod is not a serviceable part The vacuum cleaner powerhead contains electrical connections the powerhead is not a serviceable part Use the electric powerhead only for vacuuming dust and dry substances in the home Never run over the power cable with the powerhead as the cable could get damaged Never touch the brush roller while the vacuum cleaner is connected to the mains power supply To prevent unnecessary wear on the powerhead cleaning nozzle keep it moving while in operation sauber EXCELLENCE SE 400 Overview Hose connector with shutter E Front lid Handle D oide parking position FJ LcD Display Mode buttons Blow port H Power cable m Cable winder
14. r this warranty does not extend the original period of warranty The benefits conferred by this warranty are in addition to all other rights and remedies in respect of the product as outlined under the Competition and Consumer Act and other State and Territory laws Our goods come with guarantees that cannot be excluded in the Australian Consumer Law You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure sauber EXCELLENCE SE 400 23 V4 08 14
15. r on wet surfaces Always check the power cord before use the power cord and the plug should be in a good condition and must not be damaged If the mains power supply cord is damaged or defective it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Do not unplug by pulling on the power cord To unplug grasp the plug not the power cord Use only Australian and New Zealand electrical safety approved extension cords e Do not pull or carry the appliance by the power cable use the power cable as a handle or pull the power cable around sharp edges or corners Avoid running the appliance over the power cable e Ensure the appliance is switched off before unplugging e Do not handle or operate the appliance with wet hands and follow electrical safety precautions at all times e Extreme caution should be exercised when using the appliance on stairs e Do not attempt to change the attachments while the appliance is plugged in to mains power supply owitch off and remove plug from mains power supply Use only manufacturer s recommended accessories e Do not operate the vacuum cleaner too close to the heaters radiators and other hot surfaces e Do not use the appliance to pick up flammable items or combustible liquids i e petrol hot ashes and cigarettes matches explosive materials or anything burning or use in areas where such substances and items may be
16. stomer Service For Customer Service or product enquiries please visit our website or call 1800SAUBER 1800 728 237 www sauber com au www sauber co nz m n EXCELLENCE SE 400 5 Year Warranty Sauber Excellence Conditions of warranty Your Sauber cleaner in the case of domestic use has a 5 year parts and labour warranty against product defects and failures when the product is used in accordance with the terms and conditions of this warranty statement This warranty commences from the original date of purchase and is not transferable please retain your original proof of purchase for any warranty claims This warranty is valid only in the country where the cleaner is purchased The cleaner must be operated in accordance with these instructions and used only for domestic household cleaning to remove DRY dirt and dust from household carpets flooring and fabrics This cleaner is not fit to be used as an industrial cleaner and is not designed for the collection of vitreous building material including particle board construction products and similar products such as wood fibres cement fillers fibre glass etc or excessive or frequent sand The infrequent pick up of these materials in these circumstances may be harmful to your cleaner and may void the manufacturer s warranty Accessories and consumables including dust bags and filters unless defective in manufacture are not subject to this warranty In order to prol
17. use the foot pedal 10 will cause lasting damage to the machine otart at setting 4 on the height adjuster 2 and adjust according to the indicator light 6 7 The electronic brush control constantly monitors the status of the brush communicating the status through the lights on top EXCELLENCE SE 400 Start at setting 4 on the height adjuster 2 and adjust according to the indicator light 6 7 The electronic brush control constantly monitors the status of the brush communicating the status through the lights on top Green 7 and red 6 The brush is not fully engaged in the carpet The height adjustment should be lowered If the west setting the brush is worn and needs to be replaced This detail applies only to carpet Green light only 7 Brush is working well We strongly recommend in normal use selecting a brush height that is only one level beneath that at which both the green and red lights are on For maxim um cleaning performance the brush height adjustment can be lowered to its lowest setting Red light only 6 The brush is blocked see below Removing Blockages Turn off the machine unplug it and then remove the blockage Maintenance and Servicing Always unplug the vacuum from the N mains power supply before dismantling any part of the machine The vacuum cleaner powerhead contains electrical connections The vacuum cleaner powerhead is not a ser
18. viceable part Removing the Brush Roller To remove the brush roller press the button marked PRESS 9 and turn the bearing 8 downward Turn the brush 24 quickly to the right and pull it out We recommend regular removal of threads and hair which have wound around the brush roller Removing Blockages If you can only feel a small amount of suction or the brush is not functioning correctly there might be a blockage Please refer to your vacuum cleaner manual first and have a look at the Removing Blockages section Check the swivel neck of the powerhead and the orange trap door 11 on the bottom of the powerhead Also check between these two openings in the powerhead sauber EXCELLENCE SE 400 PL1 Powerclean Brush Open the shutter and gently push the powered hose in the opening Gently pull out the power cable and connect it to the power socket Connect the Powerclean brush PL 1 to the powered hose Switch on the vacuum cleaner from the electronic control Assembly of VACUFLEX a To assemble the VACUFLEX click the plate on its lodgement Application vacuum cleaner run Cleaning with VACUFLEX Use VACUFLEX to deeply clean mattresses couches Oy clean m sofas car seats and all kinds of fabric and upholstery The plate stretches the fabric surfaces creating a vacuum The green light turns on to effect This combined with the suction performance of the indicate that the