1. Excel Power Vac CENTRAL VACUUM SYSTEMS Proudly Manufactured By Auskay International User amp Maintenance Guide HOME OWNERS OPERATING amp MAINTENANCE INSTRUCTIONS PLEASE READ AND SAVE THESE INSTRUCTIONS fh fi ANET ALZ anur N 24 Micro Circuit Dandenong South Vic 3175 A S KA Tel 03 9799 3055 Fax 03 9798 0386 INTERNATIONAL www duskay com au sales auskay com adau Manufacturing Installations Services Te Pa gor thase uho value only the best DUCTED VACUUM SYSTEMS VIDEO DOOR PHONES SECURITY ALARM SYSTEMS CCTV SYSTEMS Excel Power Vac User and Maintenance Guide Congratulations on choosing EXCEL Power Vac Series II Central Vacuum System Your vacuuming will be quieter easier and healthier with all the dust and dirt being removed from the house to the main unit located in the cellar garage or outside this is a great benefit to people who suffer with allergies hay fever asthma or respiratory problems Your new EXCEL Power Vac System is designed and manufactured in Australia by Auskay International Pty Limited OPERATING amp CARE OF YOUR VACUUM Make sure the power unit is turned on at the power point and that the on off switch on the front of the unit is turned off Simply plug in the cuff end of the hose in the inlet valve located inside the house and the vacuum unit will switch on automatically Except where it is a Switchable Hose After vacuuming you should let the vacuum u
2. Damage resulting from the use of the vacuum unit without the filter or bag installed Damage to the other parts of the system such as pipes tools inlet valves wands hoses Motor damage due to incorrect maintenance obstructed ventilation holes over voltage lightning strikes ingress of water or other liquids Removal and re installation costs except as per clause 2 above Freight of parts to and from Auskay dealer or agent except as per clause 2 above
3. EXCEL 4000 EXCEL 5000 Filtration Bagless amp bag 2 in1 Bagless amp bag 2 in 1 Bagless amp bag 2 in 1 Power consumption watts am T aeai WARRANTY Sealed vac mm H2O max 3162 Auskay International Manufacturing amp Trade Pty Ltd hereby warrants its EXCEL POWER VAC for 2 3 4 or 6 years subject to the conditions specified herein 1 Warranty applies if the unit is proven to be defective due to faulty workmanship or materials during the warranty period provided that the system has not been modified tampered with or repaired by any person other than an authorised employee or dealer of Auskay 2 Where an authorised Auskay dealer or agent has installed the system this Auskay dealer or agent shall remove repair or replace and refit the defective part free of charge for the first ninety 90 from date of purchase Any cost associated with traveling outside the metropolitan area is not covered and shall be paid by the purchaser For the remainder of the warranty period any defective parts will be repaired or replaced if delivered to Auskay or its dealer or agent 3 Where an authorised Auskay dealer or agent has not installed the product the defective part will be repaired or replaced free of charge during the warranty period when delivered to place of purchase or the dealer or agent of Auskay This warranty does not cover the following Fair wear and tear and consumables such as motor brushes bearing filter bag etc
4. kind of residential building house office hotels service building consists of a network of PVC pipes throughout the house strategically positioned for maximum coverage The pipe network is equipped with suction inlets The Excel Power Vac unit must be installed in a separated room for example in a storage room in a garage or in another service room and is connected to the pipe network The user starts the Excel Power Vac unit by simply inserting the fitting of the hose into the pipe inlet If the hose is equipped with an on off switch the user can control the Excel Power Vac unit by using this switch Excel Power Vac User and Maintenance Guide MAINTENANCE ATTENTION ALWAYS UNPLUG THE POWER CABLE FROM THE POWER SOCKET AND ALWAYS WEAR PROTECTIVE GLOVES AND GOGGLES BEFORE CARRYING OUT ANY MAINTENANCE Programmed maintenance In order to keep the system perfectly operating and to avoid any possible mechanic trouble the user must overhaul the whole system at precise time intervals according to the accumulated operating time of the VAC unit For the Excel Power Vac systems maintenance keep to the instruction detailed in the table below User Replace the dust bag 32 Clean the dust bin User 54 Control the obstruction level of the air exhaust Technical service The casing of the suction unit needs periodically cleaning Use a smooth and damp cloth with some neutral soap Attention Be sure to use only water or water with neutral
5. ON The User Guide The user guide is a fundamental document written by the manufacturer to be considered an integral part of the central suction unit In case of resale offering or lease to third parties the user guide must be handed over to the new user or to the new owner The manufacturer must be informed about any ownership change We recommend storing and keeping the user guide throughout the whole operating life of the suction unit The main purpose of the user guide is to provide a correct knowledge of the user mode in order to exploit the best working and security conditions It is absolutely forbidden to duplicate copy or release totally or part of this user guide without previous written authorization by AUSKAY INTERNATIONAL owner of the trademark EXCEL POWER VAC Safety and Security Precautions Read carefully any information written in this central vac user guide regarding installation use and maintenance of the central vac unit Call the Auskay Factory or Authorised Dealer for any information you may need Make sure the central vac has been correctly fitted NEVER operate this machine near open containers of flammable solvents dry chemicals cleaners or varnishes fumes from such substances and air form a mixture that can ignite from a motor spark Where this vacuum unit is installed below combustible floor or ceiling materials and the distance between the top of the machine and the ceiling or floor is less than 900mm fit a 600x600
6. able heavy duty motors are sourced from Europe A proprietary printed circuit board controls all the functions of the power unit Internal sound insulators significantly reduce the level of noise emitted by the unit The main body of the power unit is made of a heavy duty ABS polymer material which means that you will never have to worry about dents or corrosion Automotive standard UV stable paint finish is applied to all exterior surfaces to create modern and stylish appearance a N Exhaust ABS polymer top COV OY rssssss Electric suction motor Low voltage connectors stipes AAA s Manual override switch ABS polymer Dody tment Power Co rd IEE E A E E E A A T Latch lock d ust bin nnn Metal mounting bracket x of Identification plate Power Rating Voltage Rating Serial Number N3651 4 ____ Model Number AS Number Excel Power Vac User and Maintenance Guide Technical features Unique design allows the same power unit to function with a disposable bag or without the choice is up to the user Dual inlets and a special bracket design make installation flexible and simple Twist lock dust bin attachment makes emptying a breeze Balanced motor air intake and exhaust removes excess heat out of the motor Shower proof design is suitable for internal or external mounting without a rain canopy additional parts required
7. cement sheet above machine DO NOT let the children get near the central vac unit when it is working and never let children play with suction inlets or with vac unit DO NOT install unit in a confined area or without adequate ventilation DO NOT operate machine without a filter or bag DO NOT vacuum any of the following Flammable liquids inflammable chemicals powdered coal cement lime and plaster of paris powders including talcum powder flour starch or grain dust glass fragments textile materials aluminum magnesium or other metal dust Unplug the central vac unit when The power supply cable is worn out or damaged The central vac unit has been exposed to the inclemency of the weather or excessive moisture The central vac unit has been damaged by an impact or external container has been damaged The central vac unit requires any repairing or overhauling Always wear protective gloves and mask when carrying out any maintenance operation and when unloading the dust container or replacing cleaning the filter Use only AUSKAY original spare parts Never block the air exhaust pipes and the cooling inlets of the motor Use only one inlet at a time If you are not going to use the central vac unit for a long time it is advisable to turn the power off from the wall switch and unplug the power cord from the power point DESCRIPTION OF THE EXCEL POWER VAC UNIT Operating principles The Excel Power Vac system suitable for any
8. ly and than mixed up in the dust container It is strictly forbidden to use the Excel Power Vac unit in explosion hazard places or in places where temperature pressure and moisture are out of range Any different use is strictly forbidden The manufacturer by means of written authorization must approve any alteration or modification of the suction unit to remove a specific material Any use different from the original is to be considered improper and health risk for the user and damage to the vac unit cannot be excluded Compliance with the requirements and the relevant provisions of the AS directives in force The Excel Power Vac units which are the object of this user guide fully comply with the requirements and the relevant provisions of the Australian Standards directives Excel Power Vac User and Maintenance Guide HOW TO USE THE EXCEL POWER VAC UNIT 1 Starting of the Excel Power Vac unit Plug the power cord to the power point and turn the power switch on Make sure the switch on the Power Unit is in OFF position this switch is to start the unit manually 2 Use of the Excel Power Vac unit Fit the suitable floor tool or accessory for the cleaning job you want to carry out ar Ga Fit the opposite end of the hose in to the suction inlet and the Power Unit will start automatically If you are using the switch hose turn on the switch located on the handle to start the Power Unit After finishing
9. nit run for several seconds before removing the hose from the inlet valve to ensure that all the dirt and dust has reached the main unit this will reduce the chance of build up of dirt in the pipes When vacuuming curtains and delicate objects you can use the pressure release valve located on the curved wand to reduce the suction When you use the valve on the main unit you need to switch on the unit manually by the on off switch located on the front of the unit It is not recommended to use more than one inlet valve at the same time as this will reduce the suction and could cause blockage You should not at any time vacuum plaster powder heavy objects or liquids The bag or filter must be in place before the unit is turned on failure to do so will cause motor failure and void warranty If poor suctions occurs you should replace the bag or clean the filter where applicable it is recommended to do this once a month more frequently for new home until carpet settles down to have problem free operation Contents Optional Extras 1 Power Unit Spare Filter 2 Telescopic wand Muffler 3 Upholstery tool Turbo Brush 4 Hanging bracket Canopy 5 9m flexible hose Hose Sock 6 Dual floor tool Hose Hanger 7 Crevice tool Vacpan 8 Dusting brush 12m Hose Kit 9 Rod Holder Spare Dust Bags 10 Dust Bag Ci J M rm 9 N g tom S CDD Excel Power Vac User and Maintenance Guide GENERAL INFORMATI
10. soap Alcohol or other solvents may damage the unit Wait until the unit is perfectly dry prior to start it SERVICING Servicing criteria It is strictly forbidden to operate on the Excel Power Vac to carry out any maintenance or servicing not mentioned and therefore not allowed in the user manual Only qualified technicians can carry out any maintenance or repair operations The guarantee will not apply in case of interventions carried out by non authorised staff and the manufacturer cannot be considered responsible for possible injuries to persons or damage resulting from this kind of intervention DISMANTLING General Instructions When dismantling the central suction system dispose appropriately of used parts or material which could endanger human health or well being as well as the environment if handled improperly You must be acquainted with sites companies authorized to collect and dispose of used parts and materials The disposal and or recycling of any part of the suction system must be carried out in compliance with the legal regulations in force USAGE Correct usage The Excel Power Vac systems have been designed to remove the dust small particles and and dry materials It is forbidden to use the vac system to remove textile materials plaster dust etc burning and hot materials It is strictly forbidden to remove highly explosive materials gun powder or inert materials which can trigger dangerous chemical reactions if removed separate
11. the cleaning job remove the hose from the suction inlet and the Power Unit will stop automatically Excel Power Vac User and Maintenance Guide Maintenance of Self Cleaning Filter Excel Power Vac Units come with self cleaning filter fitted Self cleaning filters may get clogged over the time and needs to be removed and cleaned ATTENTION ALWAYS UNPLUG THE POWER CABLE FROM THE POWER SOCKET AND ALWAYS WEAR PROTECTIVE GLOVES AND GOGGLES BEFORE CARRYING OUT ANY MAINTENANCE A lt 4 hold the loop with your finger g pull the loop towards centre lt squeeze filter and pull down the loop lt q pull and remove the filter Excel Power Vac User and Maintenance Guide Replacing the dust bag Excel Power Vac Units can be used with dust bags recommended Dust bags should be checked and replaced when full li ATTENTION ALWAYS UNPLUG THE POWER CABLE FROM THE POWER SOCKET AND ALWAYS WEAR PROTECTIVE GLOVES AND GOGGLES BEFORE CARRYING OUT ANY MAINTENANCE e m lt j unlock the latches amp remove the dust bin pull down and remove the old dust bag lt insert new dust bag on to bag adaptor lt replace the dust bin amp lock the latches a Excel Power Vac User and Maintenance Guide Construction features see picture Only top quality components are used in the construction of the Excel Power Vac without compromise The best avail