1. Chapter 1 Scale at a Glance Introduction Thank you for choosing one of our scales The acaia Coffee Scale is designed and manufactured to the most rigorous standard to give you the best coffee brewing experience Start by checking that your acaia Coffee Scale box contains all the parts listed below e acaia Coffee Scale e Micro USB cable Next follow the instructions in the Preparation and Installation sections in the manual to get started To take an advantage of its many features carefully read through the operation manual containing step by step procedures examples and other information Warning Incorrect handling of this product could possibly result in personal injury or physical damage Specifications Aprox weight 462g Capacity 2000g 70 540z Measuring Units g oz Maximum capacity 1000 09 35 2800Z Weighing range 1 Minimum capacity 1 0g 0 0350z Division 0 19g 0 0050z Maximum capacity 2000 0g 70 5400z Weighing range 2 Minimum capacity 1000 0g 35 2800Z Division 0 5g 0 0200z Indication limit 2060 0g 72 6600z Unit dimensions L x W x H 160x160x30mm Electrical Requirements 5V 500mA Power and Battery Lithium ion rechargeable 3 7V 1100mA Display 6 digit Blue White LED Buttons Touch sensitive Bottom anti slip rubber flat surface Connectivity Bluetooth 4 0 Linearity 0 2g Work time battery life Up to 25 hours Chapter 1 Scale at a Glance 4 Scale Overview Weighing Pan Power Key rA LED Dis
2. The number shown on LCD display indicates the current filter parameter which determines the speed for load receptor to response to weight and to determine the weighing value The larger the number the more stable but slower the weighing result will be Press I button to change the parameter Press and hold T button for 1 second until the next setting i n is shown on the LED to confirm the selected parameter Default Weighing Unit jn ihe The Default Weighing Unit is set to be gram if 4 is selected and ounce if ac jis selected Press I button to switch the Default Weighing Unit between gram and ounce _ Press and hold T button for 1 second until E5oaL is shown on LED to confirm the selected option Chapter 4 Configuration 17 Weighing resolution amp 5ai 1 The default Weighing Resolution is set to JEF ALUL the division is 0 1g under weight of 1000g and 0 5g from 1000g to 2000g Press button to switch the weighing resolution between GEFALUL Jand A bA When the Weighing Resolution is set to high division will be 0 1g throughout the entire time from Og to 2000g Press and hold I button for 1 second until 5L EEF is shown on LED to confirm the selected option Timer mode setting t_cad In firmware 1 72 the default Timer mode is set to OFF 1 OFF The Timer mode is disabled the scale will display two modes Weighing Mode and Timer Weighing Mode ON
3. 1 2 l Press QO button to start or pause the timer Press button for tare zero operation Press and hold I button for 1 second to stop and reset the timer Press and hold 4 button for 1 second to switch to Weighing Mode Chapter 3 Basics 13 Chapter 4 Configuration Setup Mode Steps to enter Setup Mode 1 Press and hold button while turning ON the scale When the LED display shows sAL A A Jand then 5 amp 4 J press and hold T button for another 1 second without releasing c button Release both and buttons when the display shows 7 U 7 with the very left O flashing 2 Press and hold T button for 1 second to move the flashing digit to the right Repeat this step for 4 times to enter the first setting in Setup Mode the LED display shows 51 EEF J Key Operations in Setup Mode 1 Press I button to toggle through setting menu or the options under each setting 2 Press and hold T button to enter each setting or to confirm the selected option 3 Press 4 button to return to setting menu without saving or to return to Weighing Mode from setting menu Chapter 4 Configuration 14 Setup Mode Settings Enter setting Auto switch off setting Auto zero setting Choose setting Zero tracking setting Key sound setting Zero range setting O O Weighing filter setting J re Default weighing unit setting Weighing resolution hiGh lt Timer mode sett
4. 1 62 the LED will display vF Appendix C Getting Firmware Version 22 Copyright The operation manual is protected by copyright All rights reserved No part of the operation manual may be reproduced processed duplicated or published in any form by photocopying microfilming reprinting or any other method in particular electronic means without the written agreement of acaia acaia Cupertino CA 2014
5. The Timer mode is turn on the scale will display three modes Weighing Mode Timer Mode and Timer Weighing Mode Chapter 4 Configuration 18 Appendix A Smart Calibration If you decide to calibrate your scale it will only be as good as the accuracy of the calibration weights you use It is recommended to use standard weights of 500g or 1000g Note We recommend standard weights with class F or Fo Advanced operation structure Note The dashed line is for firmware 1 72 the default Timer Mode is turn off 3 Press and hold key for Timer Weighing Mode 0 5 second to turn on Power on Compensation Mode Setup Mode Key operations T T T Click T key for several times Press and hold key for about 1 second Press and hold both Key and T key for about 1 second Appendix A Smart Calibration 19 Calibration Mode 1 While the scale is in Weighing Mode and the weighing unit is in gram press T button quickly multiple times until LED display shows LAL Jandthen bu 2 Here is an example of using 500g for calibration Place a 500g standard weight on scale and wait for the scale to execute calibration procedure 3 The LED display shows amp ncd when the calibration procedure is completed You may unload the calibration weight when completed Note For calibration we recommend 500g or 1000g standard weight If you always use the chemex to brew your coffee please use 1000
6. acaia Coffee Scale Operation Manual Using Your acaia Coffee Scale Identification The instructions in this operation manual apply to the acaia Coffee Scale You have purchased a quality precision weighing scale that requires handling with care Make sure to read through this operation manual prior to using the scale 1 Do not place any hot object directly on the weighing pan Please use a heat resistant pad under hot objects 2 Any modification made w warranty being voided ill result in the ithout the consent of the manufacturer w Contents NNOOOARLR DA Lee 10 10 11 12 12 13 14 14 15 16 16 16 16 17 17 17 18 19 19 20 20 21 21 22 Chapter 1 Scale at a Glance Introduction Specification Scale overview Accessories Buttons LED indicators Battery charge Chapter 2 Getting Started Preparation Charging and Setup Chapter 3 Basics An overview of operation structure Basic operations Weighing mode Timer mode Timer weighing mode Chapter 4 Configuration Setup mode Setup mode settings Auto Switch Off settings Auto Zero settings Zero Tracking Key Sound Settings Zero Range Settings Weighing filter settings Default weighing unit settings Weighing resolution Appendix A Smart Calibration Advanced operation structure Calibration mode Creep compensation mode Appendix B Error Codes Error code Appendix C Getting Firmware Version
7. efault Timer Mode is turn off Starting acaia scale 7 Turn Off n Weighing Mode T for Taring Zeroing T for weighs in different units grams and ounces Timer Mode _ for start and pause time T for clear time and stop Weighing Timer Mode O for start and pause time T for Taring Zeroing T for clear time and stop 1s Weighing Timer Mode I I l l pa ee T for clear time and stop for start and pause time Key operations T Click T key T Press and hold key for about 1 second C Click I key Chapter 3 Basics 11 Weighing Mode Display e There are two different weighing units in Weighing Mode grams and ounces The readability is 0 1g for grams and 0 005o0z for ounces The LED display shows L U when the weighing unit is in gram The LED display shows 7 7 when the weighing unit is in ounce Operation 1 Press I button for tare zero operation 2 Press and hold I button for 1 second to switch the weighing unit in between gram and ounce 3 Press and hold C button for 1 second to switch to Timer Mode Timer Mode Display e For firmware 1 2 to 1 62 The LED display shows 7 1 LU in Timer Mode e In firmware 1 72 the Timer Mode is turn off If you want to use it please see Chapter 4 Default Timer Setting for more details Operation D 1 Press button to start or pause the timer 2 Press and hold T button for 1 second t
8. g standard weight Otherwise use 500g standard weight Creep Compensation Mode 1 While the scale is in Calibration Mode and the LED display shows LAL Jandthen 5 7 press button quickly multiple times until the LED display shows LALe andthen zuu 2 Place a 2000g calibration weight on scale and wait for the scale to execute creep compensation procedure 3 The LED display shows no when the creep compensation procedure is completed You may unload the calibration weight when completed Appendix A Smart Calibration 20 Appendix B Error Codes Error Code Error Code Description 100 Code error 101 EEPROM error 102 AD read error Over load the weight is over the maximum capacity Under load the weight is under the minimum capacity 303 Unable to make zero point for the initial weight exceeds the limit 50 of capacity 304 Weight calibration error 904 Password error the default password is 0000 Appendix B Error Codes 21 Appendix C Getting Firmware Version Operations O 1 Press and hold O 5EE release while turning on the scale When the LED display shows nHL AHi H and then 2 For version 1 2 some of early birds the LED will display Eu i e For version 1 3 the LED will display Eu Z ly For version 1 4 the LED will display Eu For version 1 5 the LED will display rtu 5 Uithenr u IBC For version 1 72 the LED will display ic For version
9. ing only v1 72 t nadE Return to weighing mode Confirm modify o MANN T 2 Z Cancel modify SS Key operations T Click T key T Press and hold key for about 1 second C Click I key Chapter 4 Configuration 15 Auto Switch Off Settings 5LEEF Auto Sleep Settings can also be configured in the acaia APP 1 The number indicates the amount of time before the scale enters sleeping mode For example when 10 is selected the scale enters sleeping mode after 10 minutes of idling 2 Press I button to toggle through the options 3 Press and hold I button for 2 seconds until the next setting 4l ta J is shown on LED to confirm the selected option Auto Zero Settings U fl ta 1 When Auto Zero setting is off or disabled the initial weight on weighing pan must be less than 50 of capacity i e less than 1kg for acaia Coffee Scale before the scale is turned on otherwise an error 3 J occurs When the error occurs the scale would not work until the initial weight on weighing pan is cleared 2 When Auto Zero setting is on or enabled the scale displays the initial weight directly regardless whether the weight is over 50 of capacity Zero Tracking t AcE Zero Tracking is a function for maintaining the zero indication within certain limits automatically 1 OFF It is not recommended to turn off the Zero Tracking because the zero indication would draft easily a
10. le at a Glance LED Indicators Battery Charge Ounce Indication Charge Error Timer Reset Tare Operation Battery Charge Charge Error The upper left LED indicator lights orange when the battery is charging and turns off when the battery is fully charged The indicator flashes when there is a problem with the USB cable Timer Reset The timer displays from 0 to 59 seconds in cycle and will reset when reaching 60 seconds The lower left LED indicator lights orange when the timer resets Tare Operation The lower right LED flashes green when the T button is pressed Ounce Indication The upper right LED lights green when the weighing unit is set to ounces Battery Charge You can charge the battery by plugging the USB cable to any power supply listed below o Acomputer USB port o Acell phone charger with a micro USB connector o The supplied AC adapter o An automotive cell phone charger with a USB port or a Micro USB cable It takes 1 2 hours to fully charge the battery You can charge the battery more frequently so that it will never hit empty e A fully charged battery will last for about 25 hours of use e Battery percentage can be viewed via acaia APP It is not recommended to let the battery run out completely before charge Chapter 1 Scale at a Glance Chapter 2 Getting Started Preparation This scale is intended for indoor use elect a work place that is stable vibration free and if
11. o stop and reset the timer 3 Press and hold button for 1 second to switch to Timer Weighing Mode Note 1 The maximum time that can be displayed is 999 minutes and 59 seconds 2 The timer stops when the maximum time is reached Chapter 3 Basics 12 Timer Weighing Mode Display For firmware 1 2 to 1 62 ay The LED display shows amp G L in Timer Weighing Mode with timer on the left and the weight value on the right The timer displays from O to 59 seconds in cycle and will reset when reaching 60 seconds When it resets the LED indicator on the left lights on in orange to let you Know that more than 1 minute has passed The weight division decreases when the weight is over 199 9 The LED display shows up to 18999 in maximum Display For firmware 1 72 default setting 1 The LED display shows 4 U for grams or 2 7 1 U 7 for ounces in Timer Weighing Mode with timer on the left and weight value on the right The timer displays from 0 00 to 9 59 and then the timer will stop When the weight is more than 1000 g the LED indicator on the left lights on in orange to let you know the weight is more than 1000 g The weight division decreases when the weight is over 99 9 for grams or 70 5 for ounces The LED display shows up to 955 or 74 5 in maximum If the weight values is below zero then the LED will show up and the weight will keep flashing until it becomes positive Operation
12. play Tare Key fe Scale Front Micro B USB port Scale Back O T Note For the best performance place the weight in center of weighing platform Chapter 1 Scale at a Glance 5 Accessories Micro USB Charging Cable Type A Buttons Power Button Tare button Function Turn on Turn off Switch mode Start pause timer Back Tare Switch weighing unit Reset timer Switch option Confirm Enter calibration modes Heat Resistant Pad Example Press and hold for 0 5 seconds to turn on the scale Press and hold for over 3 seconds to turn off the scale While the scale is turned on press and hold for 1 second to switch mode Weighing Mode Timer Mode Timer Weighing Mode While in Timer Mode press to start or pause timer While in Setup Mode press to go back to Weighing Mode from menu tree While in Weighing Mode and Timer Weighing Mode press to make tare operation While in Weighing Mode press and hold to switch weighing unit While in Timer Mode and Timer Weighing Mode press and hold to reset timer While in Setup Mode press to switch options While in Setup Mode press and hold for 1 second to confirm the option selected 1 While in Weighing Mode continuously press multiple times to enter Calibration Mode 2 While in Calibration Mode continuously press multiple times to enter Creep Compensation Mode Please see Chapter 3 Basics for more details Chapter 1 Sca
13. possible a horizontal location for the weighing platform Avoid places where room temperatures are unstable Room temperature above 40 C or below 15 C may result in weighing inaccuracy Chapter 1 Scale at a Glance 8 Charging and Setup To use AC adapter instead of the built in battery plug the USB cable into the Micro B USB port located on the back panel of the scale D Press Q button for 0 5 seconds to turn on the scale Please make sure to use a heat resistant pad under hot objects Chapter 1 Scale at a Glance 9 Chapter 3 Basics An Overview of Operation Structure Note The dashed line applies to firmware 1 72 indicating that the default Timer Mode is turn off To obtain the firmware version please see Appendix C Getting Firmware Version for more details 3 Press and hold C key for Timer Weighing Mode 0 5 second to turn on To O 2 Power on l gt Timer Mode O OT Setup Mode Key operations ly Press and hold key for about 1 second Press and hold both key and key for O T about 1 second Chapter 3 Basics Basic Operations Turn On Press and hold O button for 0 5 seconds to turn on the scale Turn Off Press and hold button for 3 seconds to turn off the scale Switch Modes Press and hold button for 1 second each time to toggle through different modes Note The dashed line applies to firmware 1 72 the d
14. s room temperature changes 2 0 5d 3d For example since each division is 0 1g 3d 0 3g When Zero Tracking is set to be 3d any initial weight between 0 3g on the weighing pan would be zeroed out 3 2d is recommended in general for acaia Coffee Scale Key Sound Settings 4 Key Sound Settings can also be configured in the acaia APP Set the Key Sound function off to turn off the beeping sound or on to turn on the beeping sound Chapter 4 Configuration 16 Zero Range Setting l 4nLE Zero Range setting determines the range for which T button executes zero operation instead of tare operation ils When Zero Range is set to 2 the range for zero setting will be 2 of the capacity i e 40g for acaia Coffee Scale By pressing T button any weight within 40g is zeroed out by zero operation while any weight lays outside the range is tared out by tare operation If Zero Range is set to 100 the range for zero setting will be 100 of the capacity i e 2kg for acaia Coffee Scale Therefore instead of tare operation zero operation would be executed in this setting whenever T button is pressed Notice The difference between zero operation and tare operation is that zero operation would simply ignore the weight and display as O while tare operation would deduct the weight from weighing result However zero operation does not increase the scale capacity Weighing filter setting F E