Home
Install Manual - Automatic Solutions
Contents
1. W2 Quick reference Programming Guide Function description Choose from the relevant function below and input Enter the programmingmode 888888 then you cando the programming 888888 is the default factory master code Toexit the programmingmode Note that to undertake thef ollowing programming the masteruser must enter into the programming mode Change the mastercode 0 New code Repeat Newcode Code must be 6 8digit numbers Add card user 1 Read Card Can add cardc ontinuously Delete card user 2 Read Card Can delete car dcontinuously To Unlockthe door To Unlock the door Read user card Attachment Advanced Application 1 W2 operatingas a Controller In this mode the W2 supports a Wiegand 26 bit input soan external Wiegand device with a 26 bit output canbe connected tothe Wiegand inputterminals on the W2 Either an ID card reader 125 KHZ or an IC card reader 13 56MHZ can be connected to the W2 Cards are required to be added at the external reader except where an external EM reader is used in this case cards canbe added ateither reader or controller See igure 1 Power W2 controller wiegand reader DC12V 3A A GND Ji 12V Do E Green p D1 White reader plug ALARM H Grey 7 OPEN Yellow e D_
2. easy in operation It is anideal choice for dooraccess 3 Features Can be usedas salve reader 2 pcsW2 canbe interconnected interlocked Can be usedas controller by connecting slave reader Anti submarine back Function Alarm signal output Door open detection Standalone Card Reader User capacity 10 000 Card interface 125KHZ EMcard Remote control for programming With Manager cards for fast add and delete users Wiegand26 input output 4 Specifications Supply Voltage DC12V 10 Temperature 20 C 60 C Sleeping Current lt 15mA Humidity 20 98 Card type 125KHZ EM card Lock output load Max20A Card Reading Distance 5 10cm Alarm output load Max20A Wiegand interface Wiegand 26 Manager card Two User capacity 10 000 Dimensions 103 x 48 x23mm 5 Installation Drill holes onthe wall orprepare the cassette Wire through the hole and blanket the unusedcable in case ofshort circuit Full of 10 000 users recognizing speed lt 15ms Fix the backcover firmly onthe cassette orthe wall Attach the readerto the backcover eee A A e c Shielded cables E l 5 5 B T be D 40mm gt ee 4 6 Wiring No Color Function Description 1 Green DO Wiegand output inputsignal wire DO 2 White D1 Wiegand output inputsignal wire D1 3 Grey ALARM c
3. IN Brown p _ ef Alarm 12V Red door detecting switch Exit button GND Black VSS Blue L Purple Lt Orange ALARM a 99 oe ena eee Em card lc card g HID card has Lock Figure 1 2 W2 operatingas a Wiegand Output Reader In this mode the W2 supports a Wiegand 26 bit output so the Wiegand data lines can be connected to any controllerwhich supports a Wiegand26 bit input Seefigure 2 J1 ZN aroen D Do D1 S White ED D1 Grey EED ALARM 12V Yellow JB OPEN Geno Brown SED D_IN Red E 12V Black J GND Powerful supply Blue WED vss t Purple ip L Lola E Orange IED a As Controller with wiegand 26 input Controller w2 figure 2 3 TwoW2 units interconnected fora single door In this mode twoW2 units are usedfor a single door one for entryand the other forexit Either device acts as the controller and reader at the same time Users can be enrolled in either of the devices In this mode the user capacity for one doorcan be up to 20000 The setting ofthe two W2 units must be the same including the master code See figure 3 4 TwoW2 units interconnected amp interlocked for2 doors In this mode two W2 units are used for two doors which
4. ads The cost is a service fee which includes the first half hour and the hourly rate thereafter If any Automatic Solutions provided parts are found to be defective and within warranty these will be provided free of charge NOTE If you suspect that any parts are defective and within warranty you may wish to consider option 4 A note on this option If you decide on this option you will be asked to sign an authorisation to proceed which will provide legal authority and payment security This form has three options available of which only the first two are available to you The third option is for warranty repairs only for full install customers Self install customers requiring warranty only service need to refer to option four below IMPORTANT IN SHORT THIS OPTION WILL INCUR CHARGES OPTION 4 RETURN THE PRODUCT IF BELIEVED TO BE FAULTY As a self install customer who has purchased product if you believe the product to be faulty rather than an installation or site problem you have the option of returning the product for evaluation and to exercise your right to a replacement repair or refund as applicable All returned product is forwarded immediately to the service technicians for evaluation and response There are two main methods available to return product e Direct to the service centre this is the quickest method as it cuts out the branch delay e Via the branch of purchase slower because of the delay at the branch When choosi
5. are then interconnected and interlocked In thismode the doorscan be interlockedso that whendoor 1 isopen door 2 cannot be opened and vice versa The interlocked function is mainly used in banks prisons and other placeswhere a higher levelof security isrequired See figure 4 Power i outdoor ifidocr DC12V 3A ut re A g Green DO Do Green Whit D1 D1 White ite ED ALARM H Grey Z d Grey BD ALARM OPEN EE Yellow te Yellow iD OPEN Alarm D_IN Brown e Brown gt D_IN door detecting switch Exit button 12V Red Red ED 12V GND j Black Black JED GND VSS Blue Blue VSS L Purple Purple Jp L iz oO Lock i ALARM Orange o Orange FD A ARM W2 controller 1 W2 controller 2 figure 3 W2 controller 1 W2 controller 2 Power DC12V 3A J1 Door1 ae Door 2 J1 Do Green Green jD Do D1 White White EED 01 ALARM i Grey Grey ED ALARM OPEN Yellow g i o Yellow EED OPEN Alarm 2 D_IN Brown Alarm Brown i D_IN bas J exitbutton Exit button 12V Red Red BD 12V GND Black ack GND VSS G Bh MD vss L Ee 7 Lock 1 L
6. early as possible Don t forget to include a telephone number Be certain to detail which model or models of you are working with Send photos of the installation they love photos The people at the service desk are good but they are even better when they can see the installation Send photos of the overall scene so they can see the entire installation Also send photos of the wiring to the control board and any other part of the installation you think is relevant Send video if appropriate Smartphone s these days take remarkably good video in small file sizes which can be emailed in a moment If your problem needs a video to show the issue please feel free to send it NOTE THIS IS BY FAR THE FASTEST AND MOST SUCCESFUL WAY TO SOLVE YOUR PROBLEM PHOTOS AND VIDEOS ARE THE NEXT BEST THING TO BEING THERE OPTION 2 LODGE YOUR ENQUIRY LOCALLY SLOWER BUT CAN STILL BE EFFECTIVE Make contact with the store of purchase Branch staffs are typically not technicians and dependent on their length of service will have varying degrees of technical knowledge If they cannot help however they will certainly either source help locally from their technicians or make contact with the service technicians on your behalf OPTION 3 SERVICE CALL WITH AUTOMATIC SOLUTIONS TECHNICIAN SLOWEST METHOD If you fall within the local branch service area it may be possible to book a local technician to look at your installation Wait times will vary dependent on local worklo
7. erlock Door interlock disabled 8 0 To deleteALL users Note This option will delete all users but 2 0000 janager Cards Be carefulwith use Door interlock enabled 8j 1 Alarm output time 10 2 Door setting To setthe alarm output ime 0 3 minutes Factory default is1 minute To removethe alarm Lock Power Setting Toremove the doorforced open warning Read valid cardor Master Code Fail secure Unlocked when power on 4 O 99 This is the factorydefault 3 seconds 0 99 is to setthe door relay time0 99 seconds Toremove the dooropen too long Close the door orRead valid card warning or Master Code 5 L0 99 0 99 is to setthe door relay time0 99 seconds Fail safe unlocked whenpower is off To Unlockthe door Anti submarine Settings Read user card Note that Manager Card can tbe used to unlockthe door To Unlock the door 6 SELF INSTALL NEED TECHNICAL ASSISTANCE OPTION 1 DIRECT WITH THE SERVICE DESK QUICKEST AND MOST EFFECTIVE METHOD Submit your enquiry direct with the service desk at service automaticsolutions com au The service desk has the most experienced staff in Australia to help with your problem but they need your help Describe your problem in detail and as cl
8. for 1 minute before switching off automatically Door Forced Openwarning When usedwith an optional magnetic contact or built in magnetic contact ofthe lock ifthe door is forced open orif the dooris opened after 120 seconds of the electro mechanical lock not closed properly the inside buzzer and alarm outputwill both operate Remarks All thesteps below mustbe done afterentering into programmingmode Todisable door opendetection Factory default 0 New Password RepeatNew Password The master codemust be 6 8 digit number Tochange the mastercode Toenable door opendetection 6 1 Security Mode Setting 1 Read Card Card can beadded continuously without exiting programming mode Toadd a carduser Method 1 Reader Lockout amp Alarm Output options If there are 10 invalid cards within 1 0 minutes the Reader will lockout for 10 minutes orthe alarm will operate for 10 minutes depending on theoption selected below 1 Input Card number 8 digit Toadd a carduser Method 2 The card numberis the last8 digits ofthe number printing onthe card Normal status Nolockout or alarm 7 0 Factory default setting Reader Lockout 71 Alarm Output HIB 2 Read Card or 2 Card number 8digit Todelete a carduser Door Int
9. ng mode Red shines Short ring Enter into setting Orange shines Short ring Exist from programming mode Red shines slow Short ring Operation failed Three short ring Open the door Green shines Short ring Alarm Red shines fast Alarm 4 10 W2 Detailed Programming Guide 10 1 User settings There are 2 waysto add and deleteusers A By manager card B Byremote control Anti submarine Disabled 3 0 Factory default Anti submarine Master Mode 3j ILE Antisubmarine Auxiliary Mode 32 Note the detailed wiring diagramand illustration please referto the Advanced application A By Manager card The mostconvenient way Manager add card Read user card Manager ToAdd user by ManagerCard add card Cards can be addedcontinuously Manager delete card Read user card Manager To DeleteUser by Manager Card Delete card Cards canbe deletedcontinuously B By Remote control Manager Password 888888 is the default factory master code To Enter the programming mode Door open detection Door Open Too Long DOTL warning When used with an optional magnetic contact or built in magnetic contact of the lock if the door is opened normally but not closed after 1 minute the inside buzzer will beep automatically to remind people to close the door and continue
10. ng this option you need to complete a product return form This form gives you all the information on procedure involved and where to send to These are available at the branch of purchase can be emailed to you contact your branch or available here http automaticsolutions com au page warranty php
11. ock 2 r gt ALAR G ji o 0 se WED a ARM figure 4 5 Anti submarine functionfor single door 3 1 The connection diagramis as figure 1 Install one Wiegand reader ora W2 withoutuser information as reader outside the door connecting to one W2 Controller inside the door which acts as the Anti submarine Master unit of the two devices they build up an anti submarine system forsingle door The operation andfunction is as below 5 1 Set the needed function and enroll the User Cards on the inside W2 Anti submarine Master unit 5 2 With the valid user card the user can only enter the door from the outside reader and exit fromthe inside W2 Controller Onthe other hand without entering record from the reader the user can t exit from the controller inside also the user can t enter in twice without thefirst exit record and viceversa 6 Anti submarine functionfor 2 doors The connection diagram is as Figure 4 Door 1 with one W2 and Door 2 with one W2 set one W2on Door 1 as the Anti submarine Auxiliary unit 3 2 andset the other W2 on Door 2as the Anti submarine Master unit 3 1 They buildup a two doors anti submarine system which isnormally used for parkinglot etc The operation andfunction is as below 6 1 Set the neededfunction and enrollthe User Cards from W2 Anti submarine Master unit on Door2 6 2 With the validuser card theuser can onlyenter in from Door 1 andexit from Door2 On the other hand wi
12. ock Interface Principle Alarm Interface Principle By programme setting 1 O 12V when alarm the I O outputs high level switch between low level and Q high level Le 4 low level Zpd6 5 high level ALARM e gt L i o im a6 e ad H vO a2 R8 o H Ry R19 R20 2 L Figure 1 Note The above diagrams show the output interface circuits Unlike most lock and alarm outputs which usea relay that canbe shocked or magnetized the W2 uses MOS outputs for both theLock Output on theleft and theAlarm Output on theright 8 To Reset to Factory Default and Manager Card setting Power off use the supplied Contact Pin to short out the 2P socket on the mainboard then power on if successful the beeper will beep twice the LED shines in orange remove the Short Pin then read any two EM cards after thatthe LED turns in red means reset to factory default setting successfully of the two EM cards read the first one is Manager add card thesecond one is Manager delete card Remarks Reset to factory default setting the users information enrolled is still retained When reset to Factory default setting the two Manager cards must be re enrolled 9 Sound and Light indication Do not poweron until allwiring has beencompleted 3 Operation status LED Buzzer Reset to factory default setting Orange Two shortring Sleeping mode Red shines slow Operation successful Short ring Enter into programmi
13. onnecting to thenegative pole ofthe alarm equipment 4 Yellow OPEN Toconnect to onepart of Exit Button 5 Brown D_IN Door Contact input 6 Red 12V 12Vdc Positive Regulated Power Input 7 Black GND Negative Regulated Power Input the negative pole of the controller connect tothe other 8 Blue VSS part of Exitbutton and door contact 9 Purple L Connect to the negativepole of the Lock 10 Orange L Alarm Connect to thepositive pole ofthe lock andalarm equipment Connection Diagram we J1 Do Green D1 E White ALARM Grey OPEN E Yellow D_IN Brown 12V Red GND H Black VSS Blue L Purple ALARM Orange Common Power Supply Exit button Alarm DC12V 3A if Q door detecting switch Lock J1 DO c Green D1 White ALARM Grey Exitbutton Alarm a DC12V 3A PUSH NC COM NO OPEN Gi Yellow door detecting switch D_IN Brown aaa 12V Gi Red i GND H Black yoojasnoas 1e4 VSS H Biue J901 ayes 1e4 L aa Purple L ALARM E Orange Special Power Supply 7 Interface Circuits L
14. thout entering record from the Auxiliary unit the user can t exit from the Master unitor Auxiliary unit also the usercan t enter in twice without the first exit record and vice versa 10 W2 waterproof Standalone Proximity Reader User manual 1 Packing List Name Specification Quantity Standalone Proximity Reader w2 1 Infrared remote control 1 Manager card One for add onefor delete 2 Short Pin Used for factory default setting 1 User manual w2 1 Self Tapping Screws 3 5 27mm 4 2 Please ensure that allthe above contents arecorrect If any aremissing please notify thesupplier of the W2 2 Description The W2 is fully waterproof standalone Proximity access Reader which uses advanced microprocessor equipped with large capacity Flash memory supports up to 10 000 cards It is soeasy to add ordelete card users byusing the master card besides with Infrared remote control programmer the user can set the features by themselves including Alarm Self protection interlock and Anti submarine back Function In additional with infrared remote control programmer you can add or delete cards directly by inputtingcard number The W2 not only has the features of low power consumption automatic selection of lock anti vandal alarm and exit button but also has the protective functions against input over voltage and outputs short circuit These features make the W2safe reliable and
Download Pdf Manuals