Home

Serene User Manual

image

Contents

1. Maintenance Cleaning Cabinet Many commercially available cleaning products contain solvents that may attack the plastic components of this product and cause them to crack It is important to use only warm water and a small amount of detergent when cleaning this cooler Do not use abrasive or corrosive cleaners or boiling water o Disconnect the cabinet from the power supply before cleaning o When necessary wipe both the interior and exterior of the cabinet with a damp cloth Do NOT flush the cabinet with water Clean the door gasket once every three months Periodically check the condensation drain hole inside the cabinet to ensure proper drainage of any condensation Condenser The condenser coil is located at the back of the cabinet and should be Coil brushed regularly to remove any dust build up Disconnect the cabinet from the power supply before cleaning the condenser coil 7 A I Condenser coil Maintenance User Manual Maintenance User Manual SERENE HB80 110 Interior Light The cabinet interior light is fitted with a 5 Watt fluorescent lamp Osram 5Wg840 To replace the interior light tube 1 2 a 5 6 Disconnect the cabinet from the mains power supply Remove the light cover by carefully bending out the side clips Pull the fluorescent lamp out of the lamp holder Replace with a maximum 5 Watt fluorescent lamp Carefully align the side clips on the light cover
2. User Manual MAN6819 Rev 5 1 Oct 2014 HB80 110 SERENE Glass Door Cooler serene from SKOPE SKOPE Warranty Protection It s quick and simple Take a few minutes to register your SKOPE product and enjoy more efficient support plus other warranty benefits When registering make sure you have your cabinet serial number at hand E To register online anes Visit our website at www skope com warrantyprotection then complete and submit the online registration form Or freephone 1800 121 535 Australia 0800 947 5673 New Zealand SKOPE 1 year Extended Warranty Extend your Warranty Protection by 1 year during registration Please check you have not already organised an extended warranty through your dealer at time of purchase For pricing information on an extended warranty visit www skope com warrantyprotection Service amp Support We know you will get years of satisfaction from your new SKOPE product when you follow a few simple preventative mE maintenance guidelines y a Helpful information is available on our website www skope com serviceandsupport Thank you for purchasing a SKOPE refrigeration product SERENE HB80O 110 User Manual CONTENTS 1 Installation Safety FITSt o o oooooocononona ee eee eee Unpacking naaa naaa dee ae Whee HG od oe dane Ramee ae Shelves 2 cubs tee et oe ee oe eee hee Be eee eee eee POSO cubano ooh teasers darted eeustoue meee uae Power Supp
3. and fit back into place Reconnect the cabinet to the mains power supply SKOPE Contacts SKOPE Industries Limited NEW ZEALAND CONTACT Head Office PO Box 1091 Christchurch New Zealand Freephone 0800 947 5673 Fax 03 983 3896 E mail enquiry skope co nz Website www skope com AUSTRALIAN CONTACT A B N 73 374 418 306 PO Box 7543 Baulkham Hills B C NSW 2153 Australia Freephone 1800 121 535 Fax 1800 121 533 E mail enquiry skope com au Website www skope com Trademark Infringement The SKOPE trademark on this product is infringed if the owner for the time being does any of the following e Applies the trade mark to the product after their state condition get up or packaging has been altered in any manner e Alters removes including part removal or obliterates including part obliteration the trade mark on the product e Applies any other trade mark to the product e Adds to the product any written material that is likely to damage the reputation of the trade mark Notice of the above contractual obligations passes to e Successors or assignees of the buyer e Future owners of the product HB80 110 SERENE Glass Door Cooler User Manual MAN10601 Rev 5 1 Oct 2014 2006 SKOPE Industries Limited All rights reserved SKOPE Industries Limited reserve the right to alter specifications without notice E Gan Mo 0 MON is a registered trademark of SKOPE Industries Limited
4. binet see Figure 4 on page 9 The fluorescent light will require a period of time to stabilise following initial start up See page 10 for instructions on replacing the fluorescent lamp The cooler should be left running for 30 minutes to allow the cabinet to cool down before loading with product When loading the cabinet shelves with product o Allow air space around all the product for even cooling and efficient operation of the cooler Do not exceed a maximum of 30 kg per shelf Do not allow products to overhang the front or rear of the shelves as this will affect air flow Do not obstruct air flow from the evaporator fan inside the cabinet Do not block the drain hole inside the cabinet Operation User Manual Operation User Manual SERENE HB80 110 Temperature Adjustment The storage temperature of the cooler is regulated by a thermostat located at the back of the cabinet interior The thermostat temperature setting is preset at the factory and should not require adjustment The thermostat knob is graduated from 0 through to 6 with 1 being the warmest and 6 being the coldest The normal temperature controller setting is between 2 and 3 If further adjustment is required a To make colder turn the thermostat knob clockwise a To make warmer turn the thermostat knob anti clockwise Note Turning the knob to O will switch the refrigeration system off Y4Ig102 Thermostat knob SERENE HB80 110 3
5. cal high performance Be careful not to touch moving parts and hot surfaces For your own safety and that of others ensure that all electrical work is done by authorised personnel o Ifthe power supply flexible cord becomes damaged it must be replaced by an authorised service agent or similarly qualified person in order to avoid a hazard o This appliance is not designed to be stable in motion Use extreme caution when moving or transporting it o Ensure all necessary safety precautions are observed during installation or removal of the appliance a Do not store explosive substances such as aerosol cans with a flammable propellant in this appliance WARNING Always disconnect the cooler from the mains power supply before cleaning or maintenance CAUTION Never overload the power supply which could damage the cooler and product See the rating label inside the cabinet for the safe power supply and current draw 4 Installation User Manual Shelves Power Supply Ventilation Location Levelling Installation User Manual SERENE HB80 110 Unpacking Remove all packing material from the inside and outside of the cabinet including the foam base and all adhesive tape holding the cabinet accessories Model HB80 is supplied with two shelves Model HB110 is supplied with three shelves Remove the packing material and then position the shelves into the cabinet at the desired heights see Figure 1 below The bottom sh
6. elf on model HB80 has hooks on the back which lock the shelf in position The two top shelves on model HB110 have hooks on the back which lock the shelves in position Shelves Positioning The cooler is supplied with a power cord fitted with a 3 pin plug which exits behind the refrigeration system The power cord should be retrieved before the cabinet is positioned Ensure the power supply can be easily accessed once the cabinet is positioned so the cabinet can be disconnected from the power supply for cleaning and maintenance Ensure adequate ventilation is provided around the cooler The cooler should not be recessed or enclosed in a cabinet It is designed for free standing installation only The recommended clearance on both sides and at the back of the cabinet is 50mm The maximum normal operating conditions are 32 C climatic class 5 When positioning the cabinet o Avoid direct sunlight and warm draughts etc o Allow adequate space for the door to open fully o Ensure the cabinet is positioned on a level surface so the door shuts and seals correctly and to prevent the condensate tray from overflowing This cooler has a stabiliser foot located underneath the door hinge After final positioning the stabiliser foot should be screwed firmly down to floor level to stabilise the cabinet Turn the stabiliser foot clockwise to raise the cabinet or anti clockwise to lower the cabinet SERENE HB80 110 2 Operation Refrigera
7. ly ari ody os chad ohare e aes Seed ee eee eee wee VEMUIAUON covers ohh os CASS She ao da LOCAUOM 22 4 assess ee nde eee oa da ees bat Levelling 26 6 ida ico ee deed hme wt Gee we ea ee oe ee 2 Operation Cabinet Operation 1 0 0 0 00 aa eee es Refrigeration System 0 0 ce eee CAaDINeGULIONG css Genie ds ere Sse nau anes o bees LOGGING Goa os cack arena wore ce ee ee Oe bw ee pee oe a Temperature Adjustment 0 0 0 0 cee ee eee 3 Maintenance CTSA NG x sc Gruen te ye B s a a ep eae oh we Eta egal e Sik Ba oo ADM Shs ces sed ee eden Seve aed wh ee or hon se he Beene eb da ork bua he Condenser Coll MONOC INE 2 ass erates we ake 90h paa ore agony ee Gade eee o SERENE HB80 110 1 Installation Safety First Always observe safety precautions when using any electrical appliance Read these instructions carefully and retain them for future reference o When the appliance is used by or near young children or infirm persons close supervision is necessary especially to ensure children do not play with it Do not use this appliance for other than its intended use Do not cover the grilles or block the entry or exhaust of airflow by placing objects up against the refrigeration system Do not probe any opening Only use this appliance with the voltage specified on the cabinet rating label affixed to the appliance o Ensure the appliance has adequate ventilation as this is essential to economi
8. tion System Cabinet Light Loading Cabinet Operation If the cooler has been disconnected from the power supply for any reason allow about 10 minutes before switching it back on This allows the refrigeration system pressure to equalise before the system is restarted Before operating the cooler ensure a The cooler is positioned on a level surface The maximum operating temperature is no greater than 32 C There is adequate ventilation around the refrigeration system There is a gap of at least 50mm around the cabinet The plastic drain pin included in the bag with the user manual is placed into the drain hole at the bottom of the cabinet see image below This prevents objects from covering the drain hole o The cabinet stabiliser foot is screwed firmly down to floor level see image below a The cooler is allowed to stand for at least 30 minutes before connecting to the power supply While the cooler is operating it is normal to hear gurgling sounds caused by the flow of refrigerant when each cooling cycle ends Drain plug Stabiliser foot The evaporator fan located inside the cabinet should operate continuously from the time the cabinet is plugged in This may be verified by checking for air movement inside the cabinet The thermostat will click when the refrigeration system cycles on and off The cabinet interior light is controlled by the light switch next to the thermostat knob inside the ca

Download Pdf Manuals

image

Related Search

Related Contents

Uniden UIP165P Packet 8 Compatible 5.8GHz Digital VoIP Telephone Router (UIP165160P)    Manuel d`utilisation TT-Type P-Type  Fujitsu LIFEBOOK E743  Dynamic Barcodes Benutzerhandbuch  PortaLUX Case – Unit Dentaire mobile Manuel  

Copyright © All rights reserved.