Home

USER MANUAL

image

Contents

1. Technical data AL S3 BK V26BVC V40BVC R600a Models R600a Capacity 355ml 140 74 Net capacity 146L 81 2L Gas charge quantity 35 g 30g Pre set temp in degrees 5 5 Adjustable temp in degrees 2 10 2 10 Power Input 100W 85W Heater es Freestanding or Built in Built in Built in N of shelf 3 3 Ambient temp in degrees 5 3PC 3 33 C Net dim in mm WXDXH 595x572x820 380x572x820 Gross dim in mm WXDXH 655x665x875 415x625x845 Net weight 44 kg 34kg Gross weight 48 kg 38kg REFRIGERANT R600a R600a the set temperature Units with no heater will not raise its internal temperature if the ambient temperature where the unit is located is lower than the set temperature Subject to changes accordingly to the various references and models modifications Based on carton box packing dimensions weight Dimension Actual appliance measurements specifications and ratings may vary slightly due to technical improvements and slight manufacturing differences When dimensions are critical it is important that an effective check be made and the accompanying instructions and installation manual be read 17 code VIM 201208 BVC 01 Standard features Compressor operated R600a Available in rated voltage frequency as per country s requirements 100V 50 60Hz 220V 50 60Hz 115V SOHz Automatic defrost Humidity 65 RH 10 RH Black outer and in
2. 7 upper left hinge hole Fix the left bottom hinges by inserting the axis core first into the door s lower left hinge hole 6 Then secure the lower left hinge to finish the door replacement Fig 5 8 code VIM 201208 BVC 01 V40BVC S3 amp BK Figi lt Fi Fiac 7 a _ FigD e a LJ S 1 Fi E 1 Lower hinge Right 2 Screws 3 Door axis 4 Door 5 Top hinge Right 6 Hinge Screws 7 Top hinge Left 8 Decorative nail 9 Lower hinge Left 10 Door limit device 11 Screw Open the door to 90 degree angle take out the 2 screws 2 from lower door axis 3 remove the door 4 Remove the axis plate 3 from the door Fig A Unscrew the screw 11 located underneath the door frame and the limit device 10 and re locate it at left end side of the door frame Fig A B Take out the 3 hinge screws 6 from the top hinge right 5 and remove it Fig C Remove decorative nail 8 from left top of cabinet and install spare top hinge Left 7 at left top of cabinet with 3 screws Fig D Following the above procedure install the spare lower hinge to the left 9 Fig E Install and aligned the door Insert the plastic caps to cover the holes 8 9 code VIM 201208 BVC 01 V26BVC BURR 1 Lock screws 2 Lower hinge Right 3 Door axis 4 Top h
3. unit requires a standard 240 volt 10 amp power point 8 The power cord is 1 9m in length and is affixed to the right side at the back of the cabinet 9 As with most appliances of today this cabinet has sensitive electronic components which are susceptible to damage by lightning and electricity supply faults It is therefore advisable to use a power surge protector to avoid problems of this nature 13 code VIM 201208 BVC 01 10 Please see detailed dimensional diagrams in the preceding pages Please note The preceding diagram is for the 85mm plinth recess models Further Instructions The location you have selected for your Beverage Centre should be unencumbered and well ventilated be well away from any heat source and direct sunlight not be too damp laundry pantry bathroom etc have a flat floor have a standard and reliable electricity supply standard socket to country standards linked to the ground It is NOT recommended to use a multi socket or extension lead have a surge protector fitted to the electrical outlet be away from the microwave Note Certain microwave ovens do not have wave interference shield When placed within a 1 meter vicinity of the Beverage Center they may affect the operation of the wine cabinet do not cover the glass door with any other kind of door this unit CANNOT be integrated behind joinery Notes Not complying with any of the above instructions may result in
4. VINTEC Armoire vin Beverage Preservation Technology USER MANUAL V40BVC AL S3 BK V26BVC code VIM 201208 BVC 01 WARNING The information in this document is subject to modification without any prior notice Somes models are available in dedicated countries only VINTEC offers no guarantee for our Beverage Center if it is being used for any purpose other than that for which it was specifically designed VINTEC cannot be held responsible for any error in this manual VINTEC is not responsible or liable for any spoilage or damage to beverage or any other contents incidental or consequential to possible defects of the Beverage Center Warranty applies to the Beverage Center only and not to the content of the Beverage Center This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance R600A WARNINGS The following models use small quantity of R600A iso butane flammable refrigerant V40BVC 35g AL S3 BK V26BVC 30g For your safety please observe the following recommendations e This appliance contains a small quantity of R600A refrigerant which is environmentally friendly but flammable It does not damage the
5. VINTEC s after sales service Any intervention on the cold circuit should be performed by a refrigeration technician who should carry out an inspection of the circuit sealing system Similarly any intervention on the electrical circuit should be performed by a qualified electrician Notes Any intervention performed by a non authorized technicians by Vintec will lead to the warranty being considered as null and void POWER FAILURES In the event of a power interruption all previous temperature settings are automatically erased and it will revert to a preset temperature setting see preset chart Most power failures are corrected within a short period of time An hour or two s loss of power will not affect your beverage center temperatures To avoid sudden change of temperature while the power is off you should avoid opening the door For longer period of power failure do take steps to protect your beverage 15 code VIM 201208 BVC 01 Irrespective of the cause if you notice either abnormal temperature or humidity levels inside your beverage center be reassured that only long and frequent exposure to these abnormal conditions can cause a detrimental effect on your beverage TROUBLESHOOTING GUIDE Common problems may easily be solved saving you the cost of a possible service call Please read carefully the instruction manual and revert to troubleshooting guide chart PROBLEM POSSIBLE CAUSE Beverage center does not operate No
6. WARRANTY void Dimensional drawings V40BVC AL S3 BK gt gt p a BOO O RAA i LL CE nz Ze yyy ZT Yj Z Zi p fof A 5 Ui Oy 7 Z YU SO G TZ i GY Gy Up Wy UL YL Yi VL Ye Z D Yi Ys Uy Z Wy Us GY UY Y 7 2 Y L Z LL A Z Uf LL A YS Z a VA A 7 A Yi A Yj Z Y Y Z Z Yi i AA Yi Z Yy 7 A 7 7 Yj Zn Gj 7 Y A 7 ZZ Z Uy 0 Y D A LZ LL Y 7 Yj Weli A YY A Pan wA I Ji als ls Front Siole To 14 code VIM 201208 BVC 01 V26BVC Dimensional drawings ZW LL LN LZZ L 1 G LD 1 PY Z i im ZT Y 7 A 7 Yi Y Y 7 F Y f A f f j Yj j G 7 Y A 5 h Yj 7 Z Y F Yy 7 j Yj F Y 10 Wy A 2 ZE Gj Li VN F f Y 10 K i Y T x Y A SN ZA Tnnnnnnnnnnnnnne M Yj j T gt OS ty FA DUUO DOCO COCONUT Z ZA ee S ee D To Front idl OPERATION ANOMALIES Ensure that there is power to the electrical supply plug by connecting another electrical appliance to it Check fuse if any Make sure that the door is closed properly If your beverage center appears to be malfunctioning unplug it and contact your
7. e or relocate adjustable shelves to accommodate larger type of bottles or increase the capacity of the cellar by stacking the bottles up when necessary See removing shelves Keep small gaps between the walls and the bottles to allow air circulation As in an underground cellar air circulation is important to prevent mould and for a better homogeneous temperature within the cellar Do not over load your Beverage Center to facilitate air circulation Avoid obstructing the internal fans located inside on the back panel of the Beverage Center Do not slide the shelves outwards beyond the fixed position in order to prevent the bottles from falling Do not pull out more than one loaded shelf at a time as this may cause the Beverage Center to tilt forward Do not cover the shelves with alloy foil or other materials as it will obstruct air circulation Do not move your Beverage Center while it is loaded with beverages This might distort the body of the Beverage Center and cause back injury 5 code VIM 201208 BVC 01 TYPES OF REGULATION Please note that depending on the loading and settings chosen it takes about 24 hours for the Beverage Center to see the temperature stabilizing During this time LED seems to move erratically It is normal and this process occurs whenever the setting is modified and or whenever a large amount of bottles are added to the unit TEMPERATURE SETTINGS Important The LCD displays by d
8. efault the actual internal air temperature The temperature settings are pre set at the factory setting of 5 C In the event of a power interruption all previous temperature settings are automatically erased and it will revert to the preset temperature settings It is important to understand that there is a difference between the air temperature inside the Beverage Center and the actual temperature of the Beverage You will need to wait approximately 12 hours before noticing the effects of temperature adjustment due to the critical mass within a full Beverage Center Once the temperature is set it 1s strongly advised not to toy with it or adjust frequently The thermostat will maintain the temperature inside the Beverage Center within a 2 5 C range But the thermal inertia of the beverages and the glass is such that within this temperature range the actual temperature of the Beverage will only fluctuate 0 5 C to 1 C The controls of your beverage center POWER C NYP LIGHT RUN C V pow DISPLAY Adjust the desired cooling temperature by pressing the UP or DOWN buttons Each depression of the button will scroll through the available temperature settings in increments of 1 degree Celsius The temperature setting can be adjusted from 2 to 10 To visualize the set temperature press and hold the UP or DOWN buttons the set temperature will temporarily flash in the LED display for 5 seconds 6 c
9. er should be placed where the ambient temperature is between 5 C to 35 C If the ambient temperature is above or below this range the performance of the unit may be affected Placing your unit in extreme cold or hot conditions may cause interior temperatures to fluctuate The ideal range of temperature may not be reached See Climate Class at the end of this manual Grounding instructions The Beverage Center must be grounded in case of an electrical short circuit Grounding reduces the risk of electrical shock The Beverage Center is equipped with a power cord having a grounding wire and plug The Beverage Center plug must be plugged into a properly affixed and grounded electrical outlet Note Jn locations where there is frequent lightning surge protectors MUST be used Improper use of the grounding plug can result in the risk of electric shock Consult a qualified electrician or service person if the grounding instructions are not completely understood If the supply cord is damaged it must be replace by a qualified person in order to avoid electrical hazard Installing your Beverage Center Unpack and remove all of the protection and adhesive strips from the packaging around and inside the Beverage Center The Beverage Center must be positioned such that the plug is accessible Release the power cord Move your Beverage Center to its final location The Beverage Center should be installed in a suitable place where the compressor will n
10. inge Right 5 Door 6 Cabinet body 7 Top hinge Left 8 Lower hinge Left Unscrew the lock screws 1 Fig 1 to remove the door axis located at the bottom While holding the door firmly pull the door 5 outward and take it out Fig 2 Remove the 3 bolts and take out the right top hinge 2 Fig 3 Fix the left top hinge and the bottom left hinge with the bolts as per Fig 4 Re install the door the same way it was removed and fix back the door axis 10 code VIM 201208 BVC 01 V40 V26 SERIES UNDER BENCH INSTALLATION INSTRUCTIONS 1 Vintec beverage Center dimensions V40 Height 820mm 860mm 40mm adjustable feet Width 595mm Depth 571mm 30mm stopper Total of 601mm V26 Height 820mm 830mm 10mm adjustable feet Width 380mm Depth 572mm 30mm stopper Total of 602mm 2 This Vintec Beverage Center is not designed to be fully integrated behind a joinery door 3 Please note that For V40 a minimum cut out width of 615mm is required to facilitate installation removal and servicing For V26 a minimum cut out width of 400mm is required to facilitate installation removal and servicing 4 To provide good performance this cabinet requires adequate ventilation The Vintec Beverage Center cabinet requires 10mm clearance on both sides on top and 30mm clearance at the rear You must fit the back spacer provided it will ensure the minimum 30mm clearance at the rear A ventilation grid needs to be instal
11. led in this 30mm clearance area at the rear For good ventilation it is necessary to install a grill with a minimum size of 200x40mm at the top of the back wall or on either side at the top rear refer to diagrams on the following pages This is to allow cooler fresh air to flow into the 30mm gap at the rear of the cabinet The ventilation grill must not be installed close to an oven or next to a sealed area without access to fresh cool air Do call Vintec s Service Department for further explanation Failure to comply with the above specifications could void the WARRANTY 11 code VIM 201208 BVC 01 VENT SPECIFICATIONS Front View V40 Suitable points for ventilation grid Note only one vent is required correct power point location Suitable points for ventilation grid Note only one vent is required correct power point location 0 12 code VIM 201208 BVC 01 Cross section cabinet body T Adjustable feet mii 5 This Vintec Beverage Center is front venting The cabinet draws air from the front and rear and expels through the grill under the door at the front If a joinery kick board is being placed in front of the Beverage Center a grill of at least the same width as the Beverage Center grill and with a minimum airflow allowance of 150cm2 must be installed into the kick board 6 This unit has a power switch located on the control panel Power point location is therefore not critical 7 This
12. n for hydrocarbon refrigerants before carrying out servicing or repairs which involve the removal of covers The environment and personal safety must be considered when disposing of this appliance Please ensure the appliance is taken to a recycle center for safe recycling DO NOT dispose of the appliance in land fill as the insulation and refrigerant gas contained in these appliances are flammable Allow 24 hours before switching on the Beverage Center During this time we recommend that you leave the door open to clear any residual odors BEFORE LOADING amp PLUGGING IN THE BEVERAGE CENTER Important All models without front venting air opening are strictly for free standing only see technical chart Recommendations The location you have selected for your Beverage Center should be unencumbered and well ventilated be well away from any heat source and direct sunlight not be too damp laundry pantry bathroom etc have a flat floor have a standard and reliable electricity supply standard socket to country standards linked to the ground it is NOT recommended to use a multi socket or extension lead have a surge protector fitted to the electrical outlet away from the microwave oven Certain microwave ovens do not have wave interference shield When placed within 1 meter vicinity of the Beverage Center they may affect the operation of the Beverage Center 2 code VIM 201208 BVC 01 The Beverage Cent
13. ner finish Internal light Adjustable feet x 4 Double glass door with 3rd acrylic layer Seamless Stainless Steel door frame finish for S3 models 18 code VIM 201208 BVC 01 Copyright All rights are reserved All photocopying reproduction translation whether partial or total are strictly prohibited without prior written consent from VINTEC www vintec cellar com code VIM 201208 BVC 01
14. ode VIM 201208 BVC 01 DEFROSTING CONDENSATION HYGROMETRY VENTILATION Your beverage center is designed with Auto cycle defrost system During Off cycle the refrigerated surfaces of the beverage center defrost automatically Defrost water from the beverage center storage compartment drains automatically and part of it goes into a drainage container which is located at the back of the beverage center next to the compressor The heat is transferred from the compressor and evaporates any condensation that has collected in the pan Part of the remaining water is collected within the beverage center for humidity purposes This system enables the creation of the correct humidity level inside your beverage center required by the natural cork to maintain a long lasting seal Notes The water collected by condensation is therefore recycled Under extremely dry environmental conditions you may have to add some water into the water container provided with your beverage center All units are equipped with a double glazed glass door that has a third internal acrylic layer to minimize condensation on the glass door The beverage center is not totally sealed fresh air admission is permitted through the drainpipe Air is circulated through the unit by means of a fan fans and the slatted shelves Notes During the refrigerating cycle heat is given off and disperses through the external surfaces of the beverage center Avoid touching the surface
15. ot be subject to physical contact This center cannot be integrated behind a solid door doing so voids the warranty Leveling your Beverage Center Beverage Center must be leveled BEFORE loading your beverages Your Vintec Beverage Center is equipped with 4 adjustable feet to facilitate easy leveling VINTEC recommends that you screw the back feet toward the base so they are in the shortest position and adjust the front feet to level the Beverage Center Back spacer Compressor run appliances require proper ventilation for proper and longer usage Your Vintec Beverage Center is supplied with a back spacer Affixed the back spacer at the back of air circulation and heat evacuation 3 code VIM 201208 BVC 01 INSTALLATION OF BACK SPACER i IMPORTANT THIS SPACER MUST BE ATTACHED TO THE UNIT BEFORE INSTALLATION FOR VENTILATION PURPOSE FAILURE TO DO SO VOIDS THE WARRANTY TURNING ON YOUR BEVERAGE CENTER Plug in and switch on the unit by pressing on the power button for a few seconds When you use the Beverage Center for the first time or restart the Beverage Center after having it shut off for a long time there will be a few degrees variance between the temperature you have selected and the one indicated on the LED readout This is normal and it is due to the length of the activation time Once the Beverage Center is running for a few hours everything will stabilize Impor
16. ozone layer nor does it increase the greenhouse effect e During transportation and installation ensure that the tubing of the refrigerant circuit is not damaged e Avoid using or manipulating sharp objects near by the appliances e Leaking refrigerant can ignite and may damage the eyes e In the event any damage does occur avoid exposure to open fires and any device that creates a spark Disconnect the appliance from the mains power e Thoroughly ventilate the room in which the appliance is located for several minutes e Notify Customer Service for necessary action and advice l code VIM 201208 BVC 01 e The room for installing the appliance must be at least 1 cubic metre per 8 grams of refrigerant The refrigerant quantity contained in this appliance is listed above in grams it is also noted on the Rating Plate of the appliance It is hazardous for anyone other than an Authorised Service Person to carry out servicing or repairs to this appliance WARNING Keep ventilation openings in the appliance enclosure or in the built in structure clear of obstruction WARNING Do not use mechanical devices or other means to accelerate the defrosting process other than those recommended by the manufacturer WARNING Do not damage the refrigerant circuit WARNING Do not use electrical appliances inside compartments of the appliance WARNING In Queensland Australia the authorized person must hold a Gas Work Authorisatio
17. s during those cycles ADJUSTABLE SHELVES Adjusting removing the shelves When removing any of these shelves out of the rail compartment to fit or remove the shelf tilt the shelf as per the diagram and simply pull out or push in the shelf until it sits on the support brackets securely N 4 ab 7 code VIM 201208 BVC 01 REVERSIBILITY OF THE DOOR Warning To avoid accidents during the process of changing the door we recommend that you get assistance The glass door is heavy and may cause injury if dropped Depending on to the model and the type of handle your wine cabinet is equipped with you may have to rotate the door through 180 degrees Depending on the type of handle your wine cabinet is equipped with the door may not be reversible or may require that a left or right opening door be ordered to change the opening side 40BVC AL 1 Lower hinge Right 2 Lock screws 3 Top hinge Right 4 Lock Screws 5 Top hinge Left 6 Lower hinge Left 7 Door While holding the door firmly remove the three lock screws 2 from the lower right hinge module and remove it Fig 1 Remove the three lock screws 4 from the top right hinge and remove the hinge 3 Fig 3 Fix the top left hinge 5 at the top left corner with the three lock screws 4 Fig 4 While holding the door insert the axis core into the door s
18. t plugged in The appliance is turned off The circuit breaker tripped or the fuse is broken Beverage center is not cold enough Check the temperature control setting External environment may require a higher setting The door is opened too often The door is not closed completely The door gasket does not seal properly Turns on and off frequently The room temperature is hotter than normal A large amount of contents has been added to the Beverage center The door is opened too often The door is not closed completely The temperature control is not set correctly The door gasket does not seal properly The light does not work Not plugged in The circuit breaker tripped or a blown fuse The light is out of order The light button is OFF Vibrations Check to assure that the Beverage Center is level The Beverage center seems to make The rattling noise may come from the flow of the too much noise refrigerant which is normal As each cycle ends you may hear gurgling sounds caused by the flow of refrigerant in your Beverage center Contraction and expansion of the inside walls may cause popping and crackling noises The Beverage Center is not level The door will not close properly The Beverage Center is not level The door was reversed and not properly installed The gasket is faulty magnet or rubber is spoiled The shelves are out of position 16 code VIM 201208 BVC 01
19. tant If the unit is unplugged power is lost or turned off wait 5 minutes before restarting the unit The Beverage Center will not start if you attempt to restart before this time delay 4 code VIM 201208 BVC 01 Operating Noises To reach the desired temperature settings VINTEC Beverage Center like all Beverage Centers operating with compressors and fans may produce the following types of noises These noises are normal and may occur as follows Gurgling sound caused by the refrigerant flowing through the appliance s coils Cracking popping sounds resulting from the contraction and expansion of the refrigerant gas to produce cold Fan operating sound to circulate the air within the Beverage Center An individual s perception of noise is directly linked to the environment in which the Beverage Center is located as well the specific type of models VINTEC Beverage Centers are in line with international standards for such appliances VINTEC will always do its utmost to satisfy its customers but will not retake possession of the goods due to complaints based on normal operating noise occurrences LOADING YOUR BEVERAGE CENTER You may load your beverage bottles in single or double rows while taking note of the following if you do not have enough bottles to fill your Beverage Center it is better to distribute the load throughout the Beverage Center so as to avoid all on top or all below type loads Do remov

Download Pdf Manuals