1. technical characteristics as enclosed Act as follows remove the racks and burners by means of a straight spanner L unscrew the injectors U fig 7 and substitute it with the corresponding one tighten the injectors strongly After changing the injectors it is necessary to eliminate residual natural gas in the system To do this you have to turn to the maximum position then press the knob of each burner and wait few seconds Adjusting the burners The lowest flame point must always be properly adjusted and the flame must remain on even if there is an abrupt shift from the maximum to the minimum position If this is not so it is necessary to adjust the lowest flame point as follows start the burner up turn the tap up to the minimum position small flame remove the knob from the tap rod introduce a flat tip screwdriver in the hole F of the tap fig 8 and turn the by pass screw up to a proper adjustment of the lowest flame point As regards U LPG gas burners the by pass screw must be tightened completely INSTRUCTIONS FOR THE INSTALLER MAINTENANCE Maintenance Schedule No regular maintenance is reguired for the hotplates except cleaning The appliance should be checked by an authorised person every 7 years to ensure the safe operation of the appliance This is not covered by warranty Replacing the power supply cable If the power supply cable should be replaced
2. has been fitted check for leaks from the connections with soapy water INSTRUCTIONS FOR THE INSTALLER Gas Connection This appliance is supplied for use with Natural Gas However it can be converted for use with LPG Refer to LP conversion chapter There are two ways to carry out the connection to themain gas line A the hotplate can be connected with rigid pipe as specified in AS5601 table 3 1 B The hotplate can be connected with a flexibe hose which complies with AS NZS 1869 Australian Approved 10mm ID class B or D no more than 1 2 mm long and in accordance with AS5601 Ensure that the hose does not contact the hot surface of the hotplate oven dishwasher or other appliance that may be installed underneath or next to the hotplate WARNING Ensure that the hose assembly is restrainned from accidental contact with the flue or flue outlet of an underbench oven The hose should not be subjected to abrasion kinking or permanent deformation and should be able to be inspected along itsentire lenght Union compatible with the hosefitting must be use and connection testedfor gas leaks The supplyconnection point shall be accessible with the appliance installed Supply pipe sizing The total hourly gas consumption for the appliance is shown on the data label The reguired supply pressure i e at inlet to appliance regulator for each gas type is shown on the data label and given in page TECHNICAL CHARACTERISTIC TABLES Use
3. it is necessary to use a cable with a section of 3x0 75mm2 type HOSVV F or HOSRR F complying with the regulations in force The connection to the terminal board must be effected as shown in fig 9 9 A brown cable L phase blue cable N neutral green yellow cable ground A MAXIMUM U Se gt zZ KO Electrical Text Gas Connection Supply Cord MODEL GCT6020 Depth of cooktop casing from benchtop surface 55mm The gas Connection is male 1 2 BSP and is situated at the left hand rear of the appliance 100 mm from the side and 50 mm from the rear of the cooktop Electrical Gas Connection Supply Cord MODEL GCT9020 Depth of cooktop casing from benchtop surface 55mm The gas Connection is male 1 2 BSP and is situated at the left hand rear of the appliance 300 mm from the side and 50 mm from the rear of the cooktop NG Universal LPG 1 Rapid burner 11 2 MJ h 9 6 MJ h 2 Semi rapid burner 6 0 MJ h 5 6 MJ h 3 Auxiliary burner 3 2 MJ h 3 4 MJ h 4 Triple ring burner 10 8 MJ h 10 4 MJ h 5 Double ring burner 10 3 MJ h 9 6 MJ h 8 Control knob for burner 10 TECHNICAL CHARACTERISTIC TABLES TAPE BY es NORMAL INJECTOR PASS NOMINAL PRESSURE DIAMETER DIAMETERx HEAT INPUT N DESCRIPTION KPa 1 100 mm 1 100 mm Universal LPG 2 75 RAPID Natural 1 00 152 Universal LPG 2 75 SEMI RAPID Natural 1 00 110 Universal LPG 2 75 3 AUXILIARY Natural 1 00 TRIPLE
4. minimum INSTRUCTIONS FOR THE INSTALLER Under these conditions the outlet pressure should not vary from the nominal outlet pressure of 1 00kPa by more than 0 20kPa If the regulator appears to not perform satisfactorily then check the following points 1 If the outlet pressure is consistently too low then the inlet pressure may be too low and adjustment of an upstream regulator may be needed or an upstream regulator or valve with insufficient flow capacity may be present in the gas supply line If this is suspected then it may be necessary to repeat fhe checks whilst measuring both the inlet and outlet pressure to determine if the inlet pressure is in the range 1 13 5kPa 2 Check that the regulafor has been fitted to the gas supply line in the correct orientation the arrow on the base of the body indicates the direction of gas flow Once these checks have been completed if the regulator still fails to perform in a satisfactory manner it should be replaced Electrical connection The appliance is supplied with a standard 10 Amp service cord terminated by a 3 pin plug for connection to a standard household socket The electrical supply is required to power the electronic ignition system NOTE It will be necessary for servicing purposes to disconnect the electrical power supply The power point should therefore be accessible after the appliance is installed as specified in the local wiring regulations TESTING AP
5. servicing and shall bear any costs incurred for any de installation and or re installation required to make the appliance available for servicing Compass Capital Services trading as Kleenmaid is not liable for any consequential damage incurred during de installation or re installation Warranty registration and Proof of Purchase Please complete warranty details below and retain together with your proof of purchase document When requesting service under this warranty the Purchaser agrees that Proof of Purchase of their Kleenmaid appliance will be necessary in order to make the warranty valid Inability to provide Proof of Purchase even though this warranty is in place will not bind Compass Capital Services trading as Kleenmaid to repair the appliance at no charge under this warranty and will require the Purchaser to pay for the service costs in full Model Number Date of purchase For service assistance visit www kleenmaidhelp com au Other products available in the Kleenmaid range of appliances Washing machines Clothes dryers Dishwashers Ovens Cooktops Steam ovens Microwave ovens Built in espresso coffee machines Rangehoods Freestanding oven Compass Capital Services Pty Limited trading as Kleenmaid ABN 96138214525 Level 2 204 Botany Rd Alexandria NSW 2015 E help Akmaid com au www kleenmaid appliances com au e KLEENMAIO
6. this information in conjunction with the length of run number of elbows tees and bends the available service pressure and the supply reguirements of other installed appliances to determine a suitable pipe size For assistance in this matter refer to the appropriate section of the Installation Code AS5601 An Australian certified class B or D flexible connection may be used to connect the cooktop in accordance with the AS5601 and in particular section 4 8 Where a hose assembly is used and the cooktop is in the installed position the hose assembly shall be suitable for connection to a fixed consumer piping outlet located at a point 800 850mm above the floor and in the region outside the width of the appliance to a distance of 250mm The point of connection to consumer piping must be accessible with appliance installed Elbow positioning It is possible to reposition the elbow if required by loosening the locking nut and elbow by using two spanners Re tighten the entire assembly after the elbow has been repositioned When fitting elbow to appliance ensure that the sealing washer is fitted Regulator An appliance regulator is provided The regulator must be positioned so that the pressure test nipple is accessible when the appliance is installed Connect the gas supply to the Y B S P internal thread inlet of the regulator Refer page 10 for connection point position Assembly of Regulator The assembly of the regulator to th
7. PLIANCE OPERATION After installation the installer must fully test the appliance and ensure it operates correctly before handing it over to the customer Before Leaving Check all conection for gas leak with soap and water DO NOT use a naked flame for detecting leaks Ignite all burner both individually and concurrently to ensure correct operation of gas valve burner ignition turn gas taps to low flame position and observe stability if the flame for each burner individually and concurrently When satisfied with the hotplate please instruct the user on the correct method of operation In case the appliance fails to opperate corectly after all checks have been carried out refer to the outhorised service provider in your area GAS CONVERSIONS AND ADJUSTMENTS Data Label This appliance is suitable for Natural Gas and Universal LPG ensure that the available gas supply matches the Data Label When converting from Natural Gas to Universal LPG ensure that the NG regulator is removed and replaced with the Test Point Assembly An AGA Approved gas regulator suitable for a supply pressure of 2 75kPa should be part of the gas tank supply and the test point pressure should be adjusted to 2 75kPa Replacing the injectors If the equipment is adjusted for a type of gas that is different from the one available it is necessary to replace the burner injectors The choice of the injectors to replace must be made according to the table of the
8. TIONS FOR THE USER It is necessary that all the operations regarding the installation adjustment and adaptation to the type of gas available are carried out by authorised personnel in conformity with the regulations in force The specific instructions are described in the booklet section intended for the installer Conditions of Use This appliance is intended to be used in household and similar applications such as Staff kitchen areas in shops offices and other working environments Farm Houses By clients in hotels motels and other residential type environments Bed and breakfast type environment USING THE BURNERS The symbols silk screen printed on the side of the knob indicate the correspondence between the knob and the burner Automatic start up with valves Press and hold the control knob down whilst turning it anticlockwise to the maximum position large flame fig 1 Once the burner is alight continue to hold the knob down for about 6 seconds ATTENTION the triple ring burner switches on only in the maximum flame position Using the burners In order to obtain the maximum yield without waste of gas it is important that the diameter of the pot is suitable for the burner potential see the following table so as to avoid that the flame going out fig 2 Use the maximum capacity to quickly make liquids reach boiling temperature and the reduced capacity to heat food or maintain boiling All of the ope
9. Universal LPG 2 75 CROWN Natural 1 00 5 DOUBLE Universal LPG 2 75 CROWN Natural 1 00 1 TAPE BY PASS DIAMETER ULPG 1 100 mm NG Turns from fully in 150 45 WIRING DIAGRAM MODEL GCT6020 MODEL GCT9020 IGNITION TRIPOLAR IGNITION TRIPOLAR GENERATOR TERMINAL GENERATOR TERMINAL LN LN hz Pll MICRO UNIT MICRO UNIT 11 INSTRUCTIONS FOR USING THE MINI TRIVET The mini trivet included with this cooktop is to be Pa e s used for cooking vessels of diameter 120mm or smaller Incorrect fitment Correct fitment Warranty and Service Domestic Warranty Full three year warranty In addition to all statutory rights which you the Purchaser have under relevant laws in respect of this appliance during the first three years of ownership as the original purchaser of this Kleenmaid appliance Compass Capital Services trading as Kleenmaid guarantee that any fault caused by defective material or workmanship becoming apparent will be rectified free of charge with reference to parts and labour provided that all service is performed during normal working hours by Kleenmaid or their designated Agents Where the appliance is installed outside the normal servicing area of the above the Purchaser must pay for the cost of transporting the appliance to and from the Agent or the Agents travel cost to and from the purchaser s home Commercial Warranty One year warranty When this applia
10. area 3 INSTRUCTIONS FOR THE USER CLEANING Before any operation disconnect the appliance from the electrical supply Don t use a steam cleaner for the cleaning the hob It is advisable to clean the appliance when it is cold Enamelled parts The enamelled parts must be washed with a sponge and soapy water or with a light detergent Do not use abrasive or corrosive products Do not leave substances such as lemon or tomato juice salt water vinegar coffee and milk on the enamelled surfaces for a long time Stainless steel parts Stainless steel can be stained if it remains in contact with highly alkaline water or aggressive detergents for an extended period of time All grades of stainless steel may stain discolour or attain an adhering layer of grime in normal operation To achieve optimum surface appearance stainless steel must be kept clean regularly using the following cleaning procedures this ensuring goog performance and long service life Wash with warm soapy water and rinse with clean water Where the stainless steel has become extremely dirty with signs of surface discolouration due to periods of neglect or misuse use a stainless steel cleaner DO NOT use abrasive scourers or steel wool When removing these stains be sure to follow the polish of brushing lines Burners and racks These parts can be removed to make cleaning easier The burners must be washed with a sponge and soapy water or with a light dete
11. consultation If this eguipment should be sold or transferred to another person make sure that the new user receives the booklet so that they can learn how to operate the appliance and read the corresponding notice This is a Class 3 appliance This appliance complies with the following Directives EEC 2009 142 CE Gas EEC 2004 108 CE Electromagnetic Compatibility EEC 2006 95 CE Low Voltage EEC 89 109 Contact with foods WARNING The installation must be carried out by authorised personnel in conformity with the regulations in force CAUTION The surface temperature of underbench components exceeds 95 C To avoid a hazard underbench access must be restricted Refer to the installation instructions This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance Before powering the equipment check that it is properly adjusted for the type of gas at disposal see the installation paragraph If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Before carrying out the maintenance or cleaning the equipment
12. cooking collection Instructions for use and warranty details Gas Cooktop Model No GCT6020 and GCT9020 e KLEENMAIO Congratulations on the purchase of your new Kleenmaid appliance Your new Kleenmaid appliance has been designed and manufactured to give you years of reliable performance For best results carefully read the instructions on how to install your new appliance Correct installation will avoid delays and unnecessary service call costs Once installation is complete please read this entire instruction manual carefully and get to know the controls and the features of your new Kleenmaid appliance Again congratulations and thank you for choosing Kleenmaid THIS PRODUCT IS DESIGNED FOR DOMESTIC USE THE MANUFACTURER DECLINES ALL RESPONSIBILITY FOR DAMAGES TO THINGS OR PEOPLE DERIVING FROM INCORRECT INSTALLATION OR IMPROPER ERRONEOUS OR UNSUITABLE USE THE APPLIANCE MUST NOT BE USED BY PEOPLE INCLUDING CHILDREN WITH PHYSICAL SENSORIAL OR MENTAL IMPAIRMENTS OR BY PEOPLE WITHOUT THE NECESSARY EXPERIENCE OR KNOWLEDGE UNLESS THEY ARE SUPERVISED OR INSTRUCTED IN THE USE OF THE APPLIANCE BY A PERSON RESPONSIBLE FOR THEIR SAFETY CHILDREN MUST BE SUPERVISED TO ENSURE THAT THEY DO NOT PLAY WITH THE APPLIANCE We invite you to read this instruction booklet carefully before installing and using the eguipment It is very important that you keep this booklet together with the eguipment for any future
13. cut off power supply and allow it cool down Make sure that air circulates around the gas equipment Insufficient ventilation produces a lack of oxygen In case of an intense or prolonged use of the equipment it may be necessary to improve aeration for example by opening a window or increasing rangehood venting power if it exists The products of combustion must be discharged outside through a suction hood or an electric fan see the installation paragraph For any possible operation or modification apply to an authorized Technical Assistance Centre and demand original spare parts WHERE THIS APPLIANCE IS INSTALLED IN MARINE CRAFT OR IN CARAVANS IT SHALL NOT BE USED AS A SPACE HEATER Not for use in marine craft caravans or mobile homes unless each burner is fitted with a flame safeguard DO NOT USE OR STORE FLAMMABLE MATERIALS NEAR THIS APPLIANCE DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION DO NOT MODIFY THIS APPLIANCE Servicing shall be carried out only by authorised personnel The product label with the serial number is fixed to the underside of hob An additional label should be adhered to adjacent cabinetry for easy access refer installation instructions The manufacturer refuses all responsibility for possible damages to things or people resulting from incorrect installation or from an improper incorrect or unreasonable use of this equipment INSTRUC
14. e This panel can be made of any non combustible rigid material Refer fig 4 If the hob is going to be installed on the top of an oven precautions must be taken to guarantee an installation in accordance with current accident prevention standards Pay particular attention to the position of the electric cable and gas pipe they must not touch any hot parts of the oven Moreover if the hob is going to be installed on the top of a built in oven without forced cooling ventilation proper air vents must be installed to guarantee an adeguate ventilation with the lower air entering with a cross section of at least 200cm2 and the higher air exiting with a cross section of at least 60 cm2 Fastening the top Every cook top is equipped with a special washer A set of hooks is also supplied for mounting the cook top Depending on the type of mounting surface the suitable type of mounting hook is supplied hook A or hook B For the installation proceed as follows Remove all loose components from the top Turn the appliance upside down lay it s edges on foam packaging blocks to prevent damage to the ignition spark plugs and lay the seal S along the external border fig 5 Introduce and place the cook top in the hole made in the piece of furniture then fasten it with the screws and fastening brackets supplied fig 6 WARNING Failure to fix the cooktop to the bench could result in loosening of the gas connection thr
15. e cooktop manifold is achieved via the elbow union and sealing washersupplied The Y parallel thread connects to the manifold and the sealing washer is placed between the manifold end and the flat face on the elbow The tapered thread connects to the outlet of the regulator and is sealed on the thread using approved thread sealing tape or approved thread sealing compound The inlet of the regulator is a Y B S P thread and is connected to consumer piping or hose assembly Regulators are supplied pre adjusted and configured by the component maker for use with Natural Gas The appliance installer is not required to make an adjustment to obtain the correct outlet pressure setting An arrow on the base of the regulator indicates the direction of gas flow when the inlet and outlet of the regulator is orientated correctly When the regulator has been fitted check for leaks from the connections with soapy water en the gas supply Check the manometer zero point is correct x Connect the manometer to the cooktop pressure point This is located on the regulator 3 Turn on the gas supply and electricity and try to ignite the gas NOTE It will take additional time to light the gas for the first time as air needs to be purged from the pipes 4 With the appliance operating check the outlet pressure when all burners of the appliance are operating at maximum when the smallest burner of the appliance is operating at
16. ean ignition spark plugs Switch on electricity or check fuses Ignition spark plugs wet or dirty Flame ports blocked or wet Burner incorrectly fitted Knob not held down long enough in High position for flame safeguard where fitted to engage Dry or clean ignition spark plugs Clean or dry flame ports Ensure this component is fitted correctly Repeat lighting procedure and hold knob down for 6 seconds in High position refer page 3 Knob not set between High and Low Knob MUST be set between these positions Dirt or spillage on flame safeguard sensor where fitted Incorrect cooking pot or pan being used Incorrect cooking pot or pan used Clean flame safe guard sensor tip Refer to table page 3 Check table on page 3 for correct pot or pan to be used Pot or pan not located on burner properly Ensure pot or pan is centrally located on burner If the above points have been checked and there is still a problem with the cooktop please call the Service Centre Abnnormal Operation Any of the following are considered to be abnormal operation and may require servicing Yellow tipping of the hob burner flame Burner extinguished by cupboard doors Gas valve which are difficult to turn Sooting up of cooking utensil Burner not igniting propely burner failing to remain alight In case the appliance fails to operate correctly contact the authorised service provider in your
17. lowing Handles should be turned away from the front of the bench to avoid accidents When the burner is started up check that the flame is regular and before taking pots away always lower the flame or put it out INSTRUCTIONS FOR THE USER Burner Flame safeguard sensor where fitted Injector Ignition spark plug AON If you have a problem with the cooktop check the table below You may be able to solve the problem and this will save you from paying for a service call You will have to pay for a service call even in the warranty period if the problem is one listed below FAULT POSSIBLE CAUSES REMEDY Burner will not light even though the sparker is working No spark is obtained when control knob is activated Flames uneven or tending to lift Flames not staying on when knob released Low heat slow cooking Benchtop or knobs overheating Knob not held down long enough in Repeat lighting procedure and hold knob High position for flame safeguard down for 6 seconds in High position refer where fitted to engage page 3 Gas supply valve turned off Turn on gas supply to appliance Wrong knob turned Ensure the knob you are turning corresponds to the burner you want to light Port blockage in ignition area Ensure that ports in ignition area are clean and dry Ignition spark plugs wet or dirty Electricity supply is disconnected or switched off Dry or cl
18. nce is installed in a commercial application in addition to all statutory rights which you the Purchaser have under relevant laws in respect of this appliance during the first one year of ownership as the original purchaser of this Kleenmaid appliance Compass Capital Services trading as Kleenmaid guarantee that any fault caused by defective material or workmanship becoming apparent will be rectified free of charge with reference to parts and labour provided that all service is performed during normal working hours by Kleenmaid or their designated Agents Where the appliance is installed outside the normal servicing area of the above the Purchaser must pay for the cost of transporting the appliance to and from the Agent or the Agent s travel cost to and from the purchaser s home What these warranties do not cover Compass Capital Services trading as Kleenmaid is not responsible for any damage or malfunction unless caused by a defect in material or workmanship This includes but is not limited to abuse misuse improper installation and transportation damage Compass Capital Services trading as Kleenmaid is not responsible for conseguential damages from any malfunction This warranty does not cover wear Or breakage of consumable items such as door seals replacement of light globes or glass breakage due to impact In case of fractured glass do not use your appliance Purchaser s responsibility The Purchaser must make the appliance available for
19. ough movement of the cooktop and a gas leak may result A duplicate rating label is included with these instructions Ensure this is attached to a readily accessible surface so that the cooktop can be easily identified in the case of a service call INSTALLATION ROOM This appliance is not provided with a device for exhausting the products of combustion Therefore it is necessary to discharge these outside The room where this appliance is installed must have a natural air inflow so as to ensure a regular gas combustion and room ventilation the necessary air volume must not be lower than 20m3 Air must come from permanent openings made on the room walls that communicate with the outside The section of these openings shall correspond to at least 200 cm OPERATION ON NATURAL GAS Regulator An appliance regulator is provided The regulator must be positioned so that the pressure test nipple is accessible when the appliance is installed Connect the gas supply to the 1 2 B S P internal thread inlet of the regulator Refer to page 8 for connection point position Regulators are supplied pre adjusted and configured by the component maker for use with Natural Gas The appliance installer is not required to make an adjustment to obtain the correct outlet pressure setting An arrow on the base of the regulator indicates the direction of gas flow when the inlet and outlet of the regulator is orientated correctly When the regulator
20. racket screws 1 pack of cooktop to benchtop seals 1 duplicate rating label For conversion to LPG 1 Universal LPG sticker 4or5 injectors Additional accessory for cooking with vessels diameter 120mm or below 1 mini trivet LPG Test Point Assembly Installing the top The appliance is designed to be embedded into heat resistant benchtop capable of withstanding 85 C INSTRUCTIONS FOR THE INSTALLER Adjacent walls cupboards and protection for combustible materials Ensure that the appliance is installed in accordance with of AS NZS 5601 with regard to clearances to combustible surfaces and materials and clearances to rangehoods and exhaust fans Clearance of 200mm from the periphery of burners to vertical combustible surfaces is reguired Clearances to combustible surfaces may be reduced only if combustible surfaces are protected in accordance with AS NZS 5601 The eguipment must not be installed near inflammable materials such as curtains cloths etc Make a cut out in the benchtop with the dimensions indicated in fig 3 at a distance of at least 50 mm from the appliance border to the adjacent walls GCT6020 GCT9020 Any possible wall unit over the cook top must be placed at a distance of at least 760 mm from the top IMPORTANT A separation panel at least 10mm from the bottom of the cooktop must be included during installation to prevent access to the underside of the applianc
21. rating positions must be chosen between the maximum and the minimum ones never between the minimum position and the closing point The gas supply can be interrupted by turning the knob clockwise up to the closing position If there is no power supply it is possible to light the burners with matches setting the knob to the start up point large flame fig 1 of cookware 10 14 cm Power MJ h BURNERS Auxiliary Semi rapid Rapid 24 26 cm 20 22 cm Triple crown Double crown For cookware with diameter 120mm or below use mini trivet supplied refer fitment instructions on page 12 It is important to use cookware with the sizes specified and ensure the cookware is always correctly centred over the burner Using oversize cookware can potentially cause heat damage to your benchtop and or control knobs which will not be covered under warranty Notice When the equipment is not working always check that the knobs are in the closing position see fig 1 If the flame should blow out accidentally the safety valve will automatically stop the gas supply after a few seconds To restore operation set the knob to the lighting point large flame fig 1 and press While cooking with fat or oil pay the utmost attention as these substances can catch fire when overheated Do not place unstable or deformed pots on the burner so as to prevent them from overturning or overf
22. rgent wiped well and placed in their housing perfectly Make sure that the flame dividing ducts are not clogged Check that the feeler of the safety valve and the start up electrode are always cleaned so as to ensure optimum operation The racks can be washed in the dishwasher Gas taps The possible lubrication of the taps must be carried out by authorised personnel exclusively In case of hardening or malfunctions in the gas taps apply to the Customer Service INSTRUCTIONS FOR THE INSTALLER Important notice The operations indicated below must be followed by authorised personnel exclusively in conformity with the regulations in force The manufacturing firm refuses all responsibility for damages to people animals or things resulting from the failure to comply with such provisions This appliance shall be installed only by authorised persons and in accordance with the manufacturer s installation instructions local gas fitting regulations municipal building codes electrical wiring regulations and any other statutory regulations For Australia and New Zealand this appliance must be installed by an authorised person in compliance with AS NZS 5601 For outside of Australia New Zealand refer to the relevant installation code for gas appliances in your country INSTALLATION The installation kit contains the following 1 natural gas regulator 1 elbow 1 manifold 2 fibre sealing washers 4 brackets for assembly 4 b