Home
PureSine 150/300 Pure Sine Wave Inverter User's Manual
Contents
1. PureSine 150 300 Pure Sine Wave Inverter User s Manual Sinergex 1 Important Safety Instructions WARNING Before you install and use your Inverter please read and follow these safety instructions 1 1 General Safety Precautions 1 1 1 Do not expose the Inverter to rain snow spray bilge or dust To reduce risk of hazard do not obstruct the ventilation openings Do not install the Inverter in a zero clearance compartment as overheating may result 1 1 2 To avoid the risk of fire and electric shock ensure all wiring and and cables are in good electrical conditions and of sufficient size Do not operate the Inverter with damaged or substandard wiring 1 1 3 The PS 150 300 contains components which can produce arcs or sparks To prevent fire or explosion do not install or use in compartments containing batteries flammable materials or in locations that require ignition protected equipment This includes any space containing gasoline powered machinery fuel tanks joints fittings or other connections or components of any fuel system Precautions When Working with Batteries 1 2 1 If battery acid contacts skin or clothing wash immediately with soap and water If acid enters eyes immediately flood eyes with running cold water for at least 20 minutes and get immediate medical attention 1 2 2 Never smoke or allow a spark or flame in the vicinity of the battery or engine 1 2 3 Do not drop any metal tools or
2. equipment on the battery Doing so may result in sparking or the short circuit of the battery or possible explosion 1 2 4 Remove personal metal items such as rings bracelets necklaces and watches when working with a lead acid battery A lead acid battery can produces a short circuit current high enough to weld a ring or the like to metal causing severe burns Sinergex 2 Features 2 1 Electrical Performance Specification Model No Continuous Output Power 10 5 21 0 10 5 21 0 10 5 21 0 10 5 21 0 15 0 30 0 15 0 30 0 15 0 30 0 15 0 30 0 No Load Curent Draw 0184 015A oza oten ozsa ozsa ozsa otsa Output Waveform Pure Sine Wave THD lt 4 Input Voltage Range Power Factor Allowed cos8 90 cos8 90 Overload Short Circuit Reverse Polarity Fuse Protection Over Under Input Voltage Over Temperature Remote Control Yes On Off controlled by external switch Safety UL458 EN60950 EN50081 1 1992 EN50082 1 1992 EN55022B 1994 EMC FCC Class B EN61000 4 2 1995 EN61000 4 3 1996 ENV50204 1995 Operating Temperature 0 40 C C Storage Temperature 30 to 70 Fan Cooling Thermostatically controlled 200 x 132 x 72 mm 237 x 155 x 72 mm Dimensions L x W x H 7 87 x 5 20 x 2 83 inch 9 33 x 6 10 x 2 83 inch Weight 2 Kgs 5 4 Lbs 3 5 Kgs l 7 7 Lbs 110V mode design meets UL 458 amp FCC Class B 230V model design me
3. 3 14 8 10 5 12 5 Sinergex 4 Troubleshooting guide WARNING Do not open or disassemble the inverter Attempting to service the unit yourself may result in a risk of electrical shock or fire and void warranty Problems and Symptoms Possible Cause solutions No output voltage the LED glows RED light a Power status light Over input voltage Check input voltage blinks RED fast Reduce input voltage b Power status light Low input voltage Recharge battery blinks RED slowly Check connections and cable c Power status light is Thermal shutdown Improve ventilation blinks RED Make sure inverter s intermittently vents are not obstructed Reduce ambient temperature d Power status light Short circuit Wiring Check AC wiring glow steady RED error for short circuit Over Load Remove load
4. er is in bypass mode this connection neutral of the Inverter s AC output to input safety ground is not present so that the utility neutral is only connected to ground at your breaker panel as required Sinergex has tested the following GFCI protected 20A receptacles and found that they functioned properly when connected to the output of the Inverter Sinergex WARNING Never connect the inverter s output to the AC distribution grid such as your household AC wall outlet Doing so will damage the Inverter and void warranty 3 4 Installation Before connecting your applications to the inverter always check the power draw of your appliances The inverter will supply a greater surge power for a short time to start electrical equipment such as electric motors pumps etc that require more power while starting up When all the above requirements are satisfied and all connections are made it s the time to turn on your inverter by pushing the power switch to the 1 position The sine wave output AC voltage gently rises from AC outlet When the inverter is not Supplying power to an application for a prolonged period of time it s recommended to turn off the inverter to save your batteries since the inverter still draws a very small amount of current when there is no load connected DC input voltage status as follows DC Input over DC Input under Model Voltage Voltage Shut down Restart Shut down Restart 12V models 15
5. ets CE amp e Mark Currently all applied projects are pending 2 2 Mechanical Drawing PS 150 Sinergex Sinergex 2 3 Mechanical Drawing PS 300 ori DOSS 155 544 155 0 C610 Ve Lact 0 Ces Sinergex 3 Introduction The Sinergex PureSine series are of the most reliable and high performing true sine wave inverters available The PureSine inverters can be used in wide range of applications including portable office equipment home entertainment products computers and most AC powered products within each models size capabilities To ensure maximum performance from your Sinergex PureSine inverter it must be installed and used correctly Please carefully read and follow the instructions in this manual before installation and operation of your inverter 3 1 Front Panel Operations 3 1 1 ON OFF REMOTE switch Leave the Power ON OFF REMOTE switch in the OFF position during installation 3 1 2 LED display indicates Power Status Solid Green Pb AC Power OK Blinked Red fast Blinked Red slowly UVP Intermittent SolidRed P 3 1 3 Remote Port Placing 0 75mm and Screw type wiring connecting the remote Port and remote panel 3 2 Rear Panel Operations 3 2 1 Ventilation window Do not obstruct Allow at least 3 inches of clearance for airflow 3 2 2 Input terminals Connect 12V 24V batteries or other 12V 24V power sources Red is po
6. sitive Black is negative Reverse polarity connection will blow internal fuse and may damage inverter permanently and void warranty 3 2 3 Using 8 AWG wire connects Chassis ground and Vehicle Chassis Sinergex WARNING Do not connect the 12V model to a 24V battery the unit will be destroyed immediately Operation of the inverter without a proper ground connection may result an electrical safety hazard Damage caused by reversed polarity is not covered by warranty Make sure the power switch is in the OFF position before connecting to the battery 3 3 AC Safety Grounding During the AC wiring installation AC input and output ground wires are connected to the inverter The AC input ground wire must connect to the incoming ground of your AC utility source The AC output ground wire should go to the grounding point for your loads for example a distribution panel ground bus 3 3 1 Neutral Grounding GFCI S 110V models The neutral conductor of the AC output circuit of the Inverter is automatically connected to the safety ground during inverter operation This conforms to National Electrical Code requirements that separately derived AC sources such as inverter and generators have their neutral conductors tied to ground in the same way that the neutral conductor from the utility is tied to ground at the AC breaker panel For models configured with a transfer relay while AC utility power is presenting and the invert
Download Pdf Manuals
Related Search
Related Contents
Manual de Instruções para a Criação de Ficheiros CSR Microsoft IIS 7 Brocade Mobility 650 BA Zetros 949 02-15, 1, de-DE Duits Horizon-Medium Corner-View Bell Room Div voor netwerk.indd starrsed auto compact gebrauchsanweisung Manual de Instruções Câmaras de segurança Safe 2020 Maxisafe PC FI25 - Italiano Elta Halogen Lamp User's Manual Sharkoon Swift-Case Securita Copyright © All rights reserved.