Electric Instantaneous Water Heaters Service manual
Contents
1. JAELWA HOTRUN Electric Instantaneous Water Heaters Service manual JA ELWA Before installation quoting stage Work out with the customer what is the right model to install for the application Site assessment 1 The electrician to assess the site power supply and the requirements for the intended model Hotruns to install This should include the sub mains to the main switchboard and the total load on the load of the site 2 The plumber needs to make sure that the water supply is sufficient for the total flow of all Hotruns running simultaneously at the minimum pressure of 100kPa 3 Be aware that some multi story apartments may utilise a gravity fed water supply allow for 30 kPa for every story 9 kPa metre Both electrical and water supply requirements should be satisfied before purchasing the Hotrun water heaters JA ELWA General Installation 1 The Hotrun is supplied with two screws to mount it without the need to open up the lid of the water heater 2 The Hotrun can be mounted in any orientation g a 28 iL gt a ou v D ou w i Cc Pa A c Q O O pun JA ELWA Electrical installation 1 The Hotrun range is from 3 5 to 9 0 kW ona single phase 16 40 A or on a 2 phase 16 or 20Amp dedicated circuit 2 Ensure that the property has the desired supply to the switchboard divide the load properly if on a 3 phase supply 3 The circuit en
2. ds close next to the water heater on an isolator switch to allow for the 400mm cord to go in a compression cable gland without tension JA ELWA Water Installation 1 Ensure adequate cold water supply pipe size is installed to maintain the pressure and flow when multiple units are installed 100 1000 kPa 2 Allow for a full bore stop cock without any flow restriction to be fitted in the cold water supply to each Hotrun 3 Connect the Hotrun only with the flat seal flexible hoses supplied too much torque on the fittings can damage the internal copper coil 4 Fit the supplied flow restrictor to the cold water inlet on the Hotrun JA ELWA Water Installation Remove any other restrictions in taps shower heads and aerators JA ELWA Water Installation remove retrictions from aerators JA ELWA Initiating the Hotrun Before applying electricity open the tap to flush debris and air from the Hotrun this may take a minute to remove all the air When the water is clean and free from burst of air turn the tap off and switch on the electrical power JA ELWA Fault finding initial observations 1 The adequate supply and pressure of the water min 100kPa 2 Make sure the cold water inlet and the hot water outlet are not connected in reverse 3 The main switch or circuit breaker is switched on 4 The fuse circuit breaker is not blown triggered 5 Flow rate from cold supply is adequate for the installed H
3. e replaced JA ELWA Flow control for Hotrun water heaters 5 A LWA flow restrictor fitted on stop valve flow restrictor fitted on cold water inlet of Hotrun water heater 2 min 4 l min 4 5 l min 5 l min hotruns hotrun hotrun 35 46 72 90 JA ELWA J2ZELWA mixer mixer mixer remove restrictor remove restrictor remove restrictor from hand shower from hand shower from hand shower nozzle nozzle nozzle bush l 4 non restrictive ball valve Hotrun Hotrun Hotrun supplied restrictor supplied restrictor supplied restrictor Copper 220 mm or multiple outlet site e g hair salon plastic 225mm JA ELWA Elwa Pty Ltd GPO Box 776 Adelaide SA 5001 P 08 8353 4040 F 08 8353 4042 www elwa com au sales elwa com au
4. fficient JA ELWA Fault finding level 2 Problem 1 The Hotrun does not switch on Tests Ensured that the general conditions have been met Isolate the Hotrun unit by switching off an isolating switch and turning off the circuit breaker and secure and tag it in the off position as per the wiring rules Remove top cover from Hotrun JA ELWA Fault finding level 2 continued Check with an Ohm meter and ensure flow switches operate contacts need to close when water flows When you turn on tap and you can hear the switches click The best way to check the switch operation with a multimeter If the pressure differential switch works O K then check that the over temperature cut out s are not triggered If the contact of one of the micro switches remains closed the heating won t stop when you close the tap and it will trigger the over temperature cut out to trip In that case the micro switch needs replacement Note there are various part numbers for different models Hotruns JA ELWA Fault finding level 2 continued If so press the tab to reset and retest If triggered it can be a sign of aging or sticking of the micro switches of the pressure differential switch Measure continuity of each element 10 to 18 ohms is the expected range depending on element power rating Remedy If the tests above indicate a fault then contact Elwa Technical Support If an element is blown usually the Hotrun needs to b
5. otrun Hint Try to disconnect the hot water flexi and run it into a bucket and see if there is warm water coming through If so the problems are being caused by new tap ware or blockages in aerators or restrictors JA ELWA Problem 1 The Hotrun does not switch on when opening the tap Causes Usually attributed to water supply problems Ensure the pressure on the cold water supply is more than 100kPa while the Hotrun is in use Too much back pressure in outlets or shower heads after the Hotrun causing lack of pressure differential over the Hotrun backpressure through the cold Wrong flow restrictor installed Maximum temperature cut out switches activated due to air in the Hotrun not released before switching on the electrical supply Problem 1 Remedies Correct the water pressure problems remove any flow restrictors in outlets Disconnect the hot water flexi and run it into a bucket and see if there is warm water coming through If so the problems are being caused by new tap ware or blockages in aerators or restrictors Seek electrical assistance to check power all the way to the elements If the cut out has been triggered due to poor flushing of air from system then RESET the cut out by gently depressing button ensure electrical power is disconnected first JA ELWA Problem 2 The water that is coming out of the Hotrun is not warm enough Cause The incoming water is too cold The total flow is too high Remed
6. y A flow restrictor should have been installed If so an additional ball valve in the water supply to the Hotrun can be used reduce the flow for the purpose of the test This will increase the temperature not for Hotrun T models JA ELWA Problem 3 The hot water flow stops when trying to set the required temperature to a colder setting Cause Aerator restrictor in nozzle of outlet causing too much back pressure incorrectly balanced flow restrictor in the supply line flow from the cold supply line is less than the requirements for the Hotrun Remedy Remove the restrictors in the tap or aerator fitting Fit the appropriate restrictor to the cold supply line for the Hotrun Check that other taps or restrictors built into the supply line are not restricting the flow or reducing the pressure too much JA ELWA Problem 4 A Hotrun fitted to the upper floor of a high rise building that is gravity fed and it does not operate Cause The pressure is less than 100 kPa The pressure of water under gravity is 9 kPa per metre this equates to approximately 30 kPa per floor plus the height of the roof tank Remedy Remove all restrictors in the tap or aerator and use star inserts in soout instead of aerator Allowing full flow will often help in low pressure situations On request we can help to accommodate for most situations sometimes just leaving out the supplied flow restrictor from the cold water inlet can be su
Download Pdf Manuals
Related Search
Related Contents
Lightolier IS:7586 User's Manual E EM3971 - Cargador universal para portátil Samsung CTR364T010 دليل المستخدم Pasadores elásticos en espiral SPIROL Agio Round Inlaid Glass Table Assembly Instruction Controlador N1100 - NOVUS Produtos Eletrônicos Getting Started with uCLinux/Blackfin Development Under Windows Copyright © All rights reserved.