1. CTC Union Technologies Co Ltd Far Eastern Vienna Technology Center Neihu Technology Park 8F No 60 Zhouzi St Neihu Taipei 114 Taiwan mn MeN 886 2 26591021 886 2 26590237 sales ctcu com info ctcu com marketing ctcu com www ctcu com ISO 9001 Quality System Certified 2010 CTC Union Technologies Co LTD All trademarks are the property of their respective owners Technical information in this document is subject to change without notice PRODUCT union Quick Start Guide User Guide Ethernet over E1 LAN Extender FRM220A Eoe1 Table of Contents Introduction 1 Specifications 2 Management Features J Panel Installation 3 LED Indicators 4 DIP Settings SW1 5 DIP Settings SW2 6 DIP Settings SW3 7 Loop Back Diagnostics 8 Applications 9 Console Management 10 12 Upgrading 13 Version 1 1 September 2010 www CTCU com Introduction The FRM220A Eoe1 is a single port G 703 704 Fractional E1 DSU CSU card with built in HDLC Bridge for the FRM220 220A Series Platform Media Converter Rack The converter supports Unframed PCM31 and PCM30 framing modes The clock source may be selected internally or recovered from received E1 signal The Ethernet port utilizes a single RJ 45 connector One single model supports either unbalanced 75 ohm with two BNC connectors or balanced 120 ohm with one RJ 45 con
2. DATAPORT E1 T1 1LO000ES 1 1000E 1 1000E 2F 1000TS 1000T 5E1 ETLOOT lt 7 gt 1000EDS 1000ES 2F lt 9 gt 10 1001S 2 lt B gt 3R 2 7G 25 3S lt D gt 5E1 ET100S Eoel lt F gt 3R 10G SS SX XX lt ESC gt Previous Menu The card type FRM220 Eoel Please enter the slot number 2 20 or all 9 The slot number 9 Please select lt 1 gt Local lt 2 gt Remote Unit lt 3 gt Remote B Unit lt ESC gt Previous menu 3R 10G SS SX XX CDR Select the line card type E EOE1 and local unit Enter filename The upgrade should complete in only a couple of minutes DO NOT disconnect or pullout insert any other cards during the upgrade process 13 www CTCU com
3. timeslot 64K s_ _ iz OFF ON OFF OFF OFF 2timesiot128K__ ON ON OFF OFF OFF S3timeslot 192K OFF OFF ON OFF OFF 4timeslot 256K ON OFF ON OFF OFF Stimeslot 320K OFF ON ON OFF OFF 6timeslot 384K ON ON OFF OFF 7timeslot 448K OFF OFF ON OFF 8 timeslot 512K OFF OFF ON OFF 9 timeslot 576K OFF ON OFF ON OFF 10 timeslot 640K ON OFF OFF ON ON OFF 12timeslot 768K ON OFF ON ON OFF 13timesiot832K_ OFF ON ON ON OFF 14timeslot 896K _ s_ _ i ON ON ON ON OFF 15timeslot 960K OFF OFF OFF OFF ON 16timeslot 1024K ON OFF OFF OFF ON 17timeslot 1088K OFF ON OFF OFF ON 18timesiot 1152K__ ON ON OFF OFF ON 19 timeslot 1216K ON OFF ON 20 timeslot 1280K ON ON OFF ON 21 timeslot 1344K OFF ON OFF ON 22 timeslot 1408K ON ON OFF ON 23 timeslot 1472K OFF OFF OFF ON ON 24 timeslot 1536K ON OFF OFF ON ON 25 timeslot 1600K OFF ON OFF ON ON 26timeslot 1664K ON ON OFF ON ON 27 timeslot 1728K OFF OFF ON ON ON 28timeslot 1792K ON OFF ON ON ON 29 timeslot 1856K ON ON ON ON 320timeslot 1920K ON ON ON ON 31 timeslot 1984K CCS 6 OFF E1 Timing source Recovery ON E1 Timing Source Internal OFF E1 Impedance 120 Ohms E1 Impedance 75
4. CH02 NMC or the full CH 20 chassis CH01 Chassis CHO1M Chassis PA CHO02M Chassis AQoOeZ AC DC 2AC 2DC S amp S or AD Se CHO02 NMC Chassis i AC DC 2AC 2DC ERIL or AD FRM220 CH20 NUS Follow all ESD precautions when handling the card iga www CTCU com LED Indicators Status for FRM220A GSW SNMP uplink LED State Status PWR Green On Power on Flash During upgrade Off Power off or card disabled TD Green On Data Port TD signal space 0 Flash Data Port TD signal activit Off Data Port TD signal mark 1 RD Green On Data Port RD signal space 0 Flash Data Port RD signal activity Off Data Port RD signal mark 1 TEST Red On Any Test active Off Normal operation SigLoss Red On E1 Signal Loss Off E1 has signal SyncLoss Red On E1 frame sync loss Off E1 framing in sync ALM Red On E1 AIS RAI or BPV err Off No E1 Alarms Error Red On Error during BERT Off No error or not running BERT Link ACT Green On UTP Link is up Off UTP Link is down 100M Green On UTP Link Speed is 100M Off UTP Link Speed is 10M Link ACT Green On FRM220A Switch link up Off FRM220A Switch link down 100M Green On FRM220A Switch is 100M Off FRM220A Switch is 10M 4 www CTCU com DIP Settings Dip Switches on PCBA Switch 1 Settings DIP SW1 SW STATE Function 3 Fractional timeslot number 1 4 5 Full E1 Unframed mode ON OFF 2 ON OFF OFF OFF OFF
5. Ohms Switch 2 Settings Switch 3 Settings Deom J wem IEEE 802 3u Auto negotiation J 1 OFF ON 2 ON 3 OFF ON 4 OFF Auto Forced Manual Forced Speed 10M 100M Forced Duplex Half Duplex Full Duplex IEEE 802 3x Flow Control Enable ON Reserved Disable Notice All of these settings are ignored if the card is placed in the FRM220A CH20 with GSW SNMP or FRM220 CH20 with NMC DIP SW2 SW STATE 1 OFF ON OFF ON OFF ON OFF ON OFF OFF Timeslot 5 OFF ON ON OFF OFF Timeslot 6 ON ON ON OFF OFF Timeslot 7 OFF ON OFF ON OFF OFF ON ON OFF Timesloti2 sd ON _ OFF ON ON OFF Timesloti3_ o o 12345 OFF a ON ON ON OoN OFF Timesloti5 o Z OFF ON OFF OFF OFF ON Timeslot 17 OFF ON OFF OFF ON Timeslot 18 ON ON OFF OFF ON Timeslot 19 OFF ON OFF ON OFF ON OFF ON OFF OFF ON ON ON Timeslot 28 ON OFF ON ON ON Timeslot 29 OFF ON ON ON ON Timeslot 30 ON 6 OFF ON 678 7 ae OFF ON 8 OFF ON OxFF Notice All of these settings are ignored if the card is placed in the FRM220A CH20 with GSW SNMP or FRM220 CH20 with NMC management The card will follow the settings done via the chassis management Refer to GSW SNMP operation manual for details on managing all cards 6 www CtTCU com management The card will follow the settings done via the chassis management Refer to GSW SNMP operation manual
6. for details on managing all cards ay oe www CTCU com Loop back Test This FRM220A Eoe1 converter incorporates loop back features which allow loop back testing to confirm that the E1 loop is operating normally or not Since Ethernet is the data port side of this DSU CSU loopback cannot be supported Ethernet looped would cause a broadcast storm Therefore only loop backs that specifically can test the E1 link are supported in this model E1 Port Loop Back Local Side Remote Side E1 RLB Remote Loop Back Local Side Remote Side E1 RRLB Request Remote Loop Back Applications The FRM220A Eoe1 E1 LAN Bridge DSU CSU works in point to point applications either as a stand alone in CH01 02 04 or when placed in the FRM220A CH20 managed rack Ethernet over E1 Remote Loc Ethernet Ethernet Internal Recovery Typical Point to Point Application The E1 transmission signal traditionally has been used to carry voice within the Public Switched Telephone Network With the emergence of IP E1 has also found use as a carrier for Data E1 is able to carry Ethernet data by using HDLC High level Data Link Control WAN encapsulation The FRM220A Eoe1 uses an HDLC bridge chip to send the Layer 2 encapsulated synchronous bit stream over the Layer 1 E1 transmission A carrier can then use this transparent Ethernet to connect to a customer www CtTCU com owned broadband router The FRM220A Eoe1 supports ISO 1
7. 3239 standard HDLC encapsulation Broadband Router over E1 Router Local Remote Router Recovery Recovery Deployment in Data Communications Network 9 www CTCU com Console Management When placed in the 1 slot CHO1M or 2 slot CH02M chassis this card can be locally managed by connecting a simple serial terminal such as a notebook computer that has an RS232 port or via a commonly available USB to RS232 adapter In Windows XP HyperTerminal is an application available for emulating a serial terminal You can also search for TeraTerm or PuTTY which are free alternatives especially if the operating system is Vista or Win7 Settings Baud Rate 38 400 Data bits 8 Parity bits none Stop bits 1 Handshaking none Emulation VT 100 Connect the serial cable to the DBY Run the terminal emulation program With power on press ESC or Enter to display the Main Menu screen The following is an example KKK KKK KKK KKK KKK KKK KKK KK KKK KK KKK KKK KKK KKKK KK EER CTC UNION TECHNOLOGIES CO LTD KER REE FRM220 Eoel Manager Ver 1 01 REF KKK KK KKK KK KKK KKK KKK KKK KKK KKK KKK KKK KKK KKKKKK 1 Syne Loss Receive AIS No BERT Error No Line Code Violation No Duplex Mode Full Loopback Test Off El BERT Test Disable El Parameters LAN Parameters Switch To Remote Tab Port Reset Store Parameters Set Factory Default Please select an item Example of Mai
8. D PWR TD RD act Test Signal loss Sync loss Alarm Error 1 x RJ 45 Auto Negotiation Auto MDIX Power Card supports hot swapping Input Card 12VDC Standalone AC DC options Consumption lt 6W Dimensions 155 x 88 x 23mm D xW x H 1 x RJ 45 and 2 x BNC 2048kb s Ethernet Port Weight 120g Temperature 0 50 Operating 10 70 Storage Humidity 10 90 non condensing Certification CE EMI LVD FCC RoHS MTBF 75000 hrs 25 Tests set from console E1 Loops Remote and Request Remote Loop back 7 BERT Integral 511 pattern generator set from console Management Features The FRM220 Eoe1 has three on board 8 pole DIP Switches which can be used to configure the device for stand alone operation When placed in a stand alone chassis with DB9 console port these devices support a text based serial terminal with an easy to use menu system for configuration When placed in a managed chassis all DIP settings are ignored and the card is configured and monitored through the chassis NMC network management controller via console Telnet Web HTTP or SNMP 2 www CTCU com Panel Figure 1 Front Panel of FRM220A Eoe1 E1 Balanced on RU48C gt E1 Unbalanced on BNC Ethernet on RJ45 P FRM220A Eoe1 Installation Figure 2 Slide in Card mounting of FRM220A Eoe1 This converter card can be placed in the CHO1 with external AC adapter CHO1 w built in power CHO1M CH 02M
9. ave function is performed F Set Factory Default This menu item will return the card to factory default settings 11 www CTCU com E1 Parameter Setting The following screen capture shows the E1 setting items and current values Choose the menu item and select the desired parameter To exit press lt ESC gt and then do not forget to save settings by pressing lt s gt KKK KKK KKK KKK KKK KKK KKK KKK KKK KKK KKK KKK KKKKAKKK kkk CTC UNION TECHNOLOGIES CO LTD eee FRM220 EoEl Manager Ver 1 01 koe KKK KKK KKK KKK KK KKK KKK KKK KKK KKK KKK KKK KKK KKKKEK Local Version 1 000 1 001 1 100 0 000 CH 01M El Parameter Setting lt 1 gt Line Code HDB3 lt 2 gt Timing Source Internal lt 3 gt Line Impedance 120 ohms lt 4 gt Idle Code 7E H lt 5 gt Auto Transmitted AIS Disable lt 6 gt Frame Mode Framed lt 7 gt Frame Format ccs lt 8 gt Time Slot Setting 0 v 1 v 8 Iv 9 v 11 v 16 v 17 v 19 v 24 v 25 v 27 lt ESC gt Go to previous menu Please select an i wv 3 Ethernet Port Parameter Setting The following screen capture shows the Ethernet port setting items and current values Choose the menu item and select the desired parameter To exit press lt ESC gt and then do not forget to save settings by pressing lt s gt KKK KKK KKK KKK KKK KKK KKK KKK KKK KKK KKK KKK KKKKKKK a CTC UNION TECHNOLOGIES CO LTD KER FRM220 EoEl Manager Ver 1 01 KER kkkkxkxkxkxkxkxk
10. n Menu Console Screen FRM220A Eoe1 10 www CtTCU com Operation Select any of the menu items by keying in the menu item number or letter Use the ESC to return to a previous menu Any setting is immediately applied to the cards circuitry but not saved After all of the parameter settings have been selected press s from the main menu to save the parameters in non volatile RAM NVR To revert to previous settings before saving press r to reset reload previously saved parameters Explanation of Settings 1 Port Active This menu item can disable or enable the card 2 E1 Loopback Test The diagnostic loopback for the E1 port is enabled through this menu item 3 E1 BERT Test This item can enable the integral 511 pattern generator for BER Testing 4 E1 Parameters This menu provides all of the settings related to the E1 such as frame type line code and timing setting 5 LAN Parameters This menu provides all of the settings related to the LAN port such auto duplex and speed setting T Switch To Remote Tab This converter has the ability to manage the remotely connected Eoe1 by using SA bits This out of band remote management means no active timeslot must be dedicated for remote management R Port Reset If changes to the configuration are made but not saved this reset function will bring the card back to the previous saved state S Store Parameters Changes are not saved to non volatile RAM until this s
11. nector When the FRM220A Eoe1 card is placed in the FRM220 rack with SNMP management the management can view the converter card s status type version Ethernet link status and alarms The card can be configured to enable or disable the port reset the card set clocking frame mode and provide analog diagnostic loopbacks A unique feature of the FRM220A Eoe1 is the use of a common card design which may either be inserted in the FRM220 CHO01 single slot chassis as a stand alone modem or as a card when placed in the FRM220 CH20 In band managed rack Features Standalone type 1 port E1 to HDLC converter Uplinks 100M Ethernet to Gigabit trunk card of FRM220A Interface connectors RJ 48C for 120Q BNC 2 for 75Q E1 settings e Line Code HDB3 or AMI e Full or Fractional e Frame setting E1 CCS CAS e Idle code setting Ox7E or OxFF Auto generate AIS enable disable setting Timing source setting Receive E1 recovery or internal oscillator Active timeslot number setting E1 CCS 1 31 or E1 CAS 1 30 Base timeslot setting E1 CCS 1 31 E1 CAS 1 15 or 17 31 Loop Back with integral BERT LED indicators 1 www CTCU com Specifications G 703 Interface Connector Data rate 7 Impedance 75 ohm for unbalanced 120 ohm for balanced Framing CCS CAS Unframed RxSensitivity 43dB extra Long Haul 7 TxPulseAmp 3 00V p p 120 ohm 2 73V p p 75 ohm Line code HDB3 or AMI selectable Indications LE
12. xkxkxkxkkkxkxkkxkkkxkkkkkkkkkxkkkxkkkkkkxkxkx k Local Version 1 000 1 010 1 100 0 000 CH 01M LAN Parameter Setting lt 1 gt LAN 1 Negotiation lt 2 gt LAN 1 Speed lt 3 gt LAN 1 Duplex Auto 100M Full lt 4 gt LAN 1 Flow Control Enable lt ESC gt Go to previous menu Please select an item 12 www CTCU com Upgrading The FRM220A EoE1 card may be firmware upgraded when it is placed in the FRM220 A with management card The user may use a local console connection to the NMC a remote Telnet IP connection or a Web based HTTP connection with any available browser The NMC communicates to all cards through a serial RS485 control bus The upgrade code is transferred to the NMC by way of TFTP server Quick Procedure Place the line card s upgrade code on the TFTP server Make sure you know the case sensitive file name Connect to the FRM220 NMC by local console or by remote Telnet connection From the main menu choose lt L gt SNMP System Configuration Setup Then lt U gt Upgrade Line Card Menu KKK KK KKK KKK KKK KKK KKK KKK KKK KKK KKK KKK K KKK CTC UNION TECHNOLOGIES CO LTD KEKKEEREKEREKERKKEERKERRKKRKEREKERKEERKEREREE lt lt Upgrade Line Card Menu gt gt Target IP 59 125 162 252 Target Gateway gt 569 125 162 241 TFTP Server IP 59 125 162 243 Please select a card type lt 1 gt 10 1001 and FMC 10 100I1 SERIAL lt 2 gt FXO FXS 155MS lt 5 gt