Home

Maintenance and Troubleshooting of Oil Diffusion Pumps

image

Contents

1. careful attention must be paid to ensure safe operation e Qil diffusion pumps should never be used for roughing because exposure to atmospheric pressure levels can cause hot hydrocarbon fluids to ignite or explode e Air leaks into the system also present safety concerns for the same reason e Avoid contaminating the pumping fluid with foreign matter because it can change its viscosity and obstruct flow passages e Operation of the diffusion pump without circulating cooling water to the main body cooling coils is also dangerous and will lead to unstable operation Some more basic operating rules e Do not turn on the heater without fluid in the pump This may damage the heaters and pump assembly e Do not air release the pump while the boiler is hot Most diffusion pump fluids break down under these conditions e Do not power the pump heaters unless cooling water is circulating This can cause the pump and fluid to overheat and will lead to unstable operation e Do not operate the pump without a foreline baffle This may cause a greater than normal fluid loss Diffusion pump maintenance It is recommended to keep logbooks for diffusion pumps to track maintenance history and operational manuals to ensure maintenance is done per the manufacturer s recommendations During maintenance activity the surfaces inside the vacuum diffusion pump need to be kept very clean in order to avoid contaminating the vacuum chamber Even a s
2. fluid becomes fully degassed If multiple processes are run on the same pump or vacuum chamber there is the risk of cross contamination of byproducts through the fluid It may become necessary to change the fluid more often in this situation After maintenance the pumpdown characteristics of the system should be monitored The best approach Is to keep a log that compares the pumpdown curves after maintenance over time This approach will help to provide an early warning of system leakage When a leak is identified the first step should be to check the following Items e The integrity of the inlet and foreline connections e The tightness of the drain and fill plugs e The other compression fittings such as those that connect the high vacuum gauges e Threaded connections such as the foreline gauge Also check the performance and accuracy of the vacuum gauges used in the system In some cases cooling coils may become obstructed due to solid deposit buildup Check the tlow meters used to measure the cooling water flow to ensure that water can flow freely through the coils and that the flow rate does not fall below the manufacturer s specifications Heater elements may burn out from time to time and need to be replaced As a preventive precaution when the pump Is cold check that the heaters are bolted snugly to the boilerplate and that all heater terminal connections are fastened tightly inside the junction box Also check the
3. total heater power input and load balance The following other items should be checked on a regular basis e The position of the system valves should be checked before repositioning e he level of the diffusion pump fluid e Confirm that water is flowing through the cooling water lines Diffusion Pump Troubleshooting Guide Poor system pressure Leaks in system virtual or real Locate and repair High process gas load Measure gas load eliminate cause System Is dirty Clean system to reduce outgassing Low heat input Check voltage Check for continuity burned out a an Inadequate cooling water flow Check water pressure Check tubing for obstructions o U High forepressure Check for leak in foreline poor mechanical pump performance breakdown of mechanical pump fluid Malfunctioning pump assembly Fluid outgassing Condition fluid by operating the pump for a few hours Leak in system ahead of pump inlet Check and correct High chamber Forepressure too high Check for leak in foreline poor mechanical pump performance contamination of the pump breakdown of pump fluid and incorrect valve operation fluid Prolonged operation in overload Adhere to operating procedures range Cutting over from the backing Cut over at a lower chamber pressure pump too early in the pump down cycle Improper system operation and air Adhere to operating procedures release procedures Pump will not start Safety circuits or protective dev
4. e How Diffusion Pumps Work e Operating Diffusion Pumps e Diffusion Pump Maintenance e Diffusion Pump Troubleshooting Guide Maintenance and Troubleshooting of Oil Diffusion Pumps solution Note Agilent VHS 4 Diffusion Pump Oil diffusion pumps are still a widely used type of high vacuum pump This is because they are relatively inexpensive highly reliable and very durable Yet oil diffusion pumps require careful maintenance in order to maintain a high level of performance and maintain the integrity of the vacuum chamber This application note will explain practical steps that can be taken to ensure optimal performance of oil diffusion pumps in a production environment How oil diffusion pumps work Diffusion pumps differ from conventional mechanical pumps in that they use a high speed jet of fluid to direct gas molecules in the pump throat down to the bottom of the pump and out the exhaust which is usually called the foreline The high speed jet is produced by boiling the fluid such as silicone oil and then directing the vapor through a series of vertically stacked cone shaped jet assemblies Typically there are three jet Stages of diminishing size with the largest at the bottom and the smallest at the top The boiling oil moves upward through the jet assemblies and then is expelled in a downward direction at the top of each assembly Exiting from the jets the high energy oil droplets travel downward in the periphery of the cha
5. ices Check utilities flow devices switches interlock prevent contactor trom staying Check thermostat operation closed Conclusion Diffusion pumped vacuum systems often provide the most efficient and cost effective environments for production processes To secure these benefits it is extremely important to follow the simple maintenance practices described here or as recommended by the pump manufacturer A small investment in planned maintenance can yield a high return in the ongoing high level performance of your production system For more information North and South America Agilent Technologies 121 Hartwell Avenue Lexington MA 02421 USA Toll free 1 800 882 7426 vpl customerservice agilent com Europe and Other Countries Agilent Technologies Italia S p A via F lli Varian 5410040 Leini Torino Italy Toll free 00 800 234 234 00 vpt sales agilent com vpt customerservice agilent com www agilent com chem vacuum References Diffusion Pumps Performance and Operation Hablanian American Vacuum Society 1994 Hablanian M H High Vacuum Technology 2nd ed New York Marcel Dekker 1997 207 Agilent Technologies Diffusion Pump Operational manual 699901140 L i E Zi Agilent Technologies T a x
6. ingle fingerprint can outgas water vapor and other molecules When a pump is disassembled for routine maintenance and cleaning it should be purged with dry nitrogen just prior to use When a diffusion pump Is pumping at a slower than normal rate look for outgassing of moisture on the surfaces of plastics or other volatile substances or a leak Check the condition and level of the fluid when the pump Is cold Withdraw a sample through the drain and visually check the level of fluid through the sight glass Use new o ring gaskets when replacing fill and drain plugs During maintenance intervals if there is diffusion pump oil loss log the amount This loss of fluid can be caused by e Air leaking into the pump e Inadequate water cooling e Continuous operation in the overload inlet pressure range also referred to as the knee of the curve e Failure to insert the foreline baffle in the pump assembly The recommended frequency at which the diffusion pump fluid should be changed depends on the specific process Slight discoloration of the fluid does not affect pump performance but material build up can lead to inefficient heat transfer For a dedicated manufacturing process it is possible to establish color based standards to help provide guidance for fluid replacement It s important to note that new fluid is subject to outgassing This can cause periods of foreline pressure fluctuations These will quickly resolve themselves as the
7. mber at speeds up to 335 meters per second The vapor jets entrain gas molecules and direct them towards the exhaust port where they are pumped away by a roughing pump The effect of removing molecules is to create high vacuum in the upper portion of the pump which is connected to the vacuum chamber fhe Agilent Technologies A roughing pump lowers the pressure inside the diffusion chamber to approximate 10 2 mbar or lower This makes It possible for the diffusion pump to create a vacuum ranging from 10 3 to 10 9 mbar 10 1 to 10 7 Pa Pumps and jet designs have evolved over the years and improved synthetic fluids have been developed enabling the high levels of vacuum to be achieved with this pump technology The pump external housing or shell is generally water cooled to prevent thermal runaway In all diffusion pumps a small amount of backstreaming movement of oil molecules into the vacuum chamber occurs In many applications this is acceptable In more critical applications an optically dense baffle is typically provided to deflect particles before they can reach the process stream A trap is placed above the baffle and cooled to a low temperature to condense hydrocarbons and water vapor from the pump chamber Due to the possibility backstreaming diffusion pumps may not be suitable for use with the most sensitive analytical equipment Operating diffusion pumps A large amount of energy is stored in an oil diffusion pump so

Download Pdf Manuals

image

Related Search

Related Contents

Wall Mount Kit - Elo Touch Solutions  お客さま各位  黒板面の光沢度試験における測定の不確かさ【PDF:143KB】  ICAI STUDENT REGISTRATION PORTAL USER MANUAL FOR  Frecuencia del hábito tabáquico entre estudiantes adolescentes de    Piero Rossi  Otimização de Processo de Decisão no Handover Vertical em  Verbatim DVD+R DL Wide Inkjet Printable 8x    