Home
VV600/VV602Plus Planning and Installation manual
Contents
1. e Industry Safes filing cabinets and other storage areas e Pharmacies and hospitals Drug cabinets vaults and safes and instrument stores e Computer rooms Tape and disk cabinets safes e Jewellers shops Vaults safes and show cases e Museums Safes vaults and store rooms e Galleries Show cases e Private homes Safes Planning and Installation manual VV600 VV602Plus 3 1 2 Function The detection principle is based on the structural vibrations generated in walls floors ceilings and doors upon an attempt to break through such physical barriers The Aritech VV600Plus System features a high level of discrimination between real attacks and normal background noise generated by human activities effectively reducing the level of unwanted alarms to almost zero To achieve this three important parameters are analysed before an alarm is triggered e o signal strength amplitude e signal frequency e o signal duration These parameters are very different between real attacks and normal background vibrations In general one may describe the signal characteristics of a true break in attempt as per below Explosive means generate a signal with a very high amplitude and a short duration Mechanical destruction generates signals with a moderate to high amplitude and a long signal duration Rotating devices generate signals with a moderate to high amplitude and a long signal duration Thermal devices genera
2. 2 1 System components VV600Plus Safe and vault vibration detector VV602Plus Detector for protection of ATM s and Night Safe Deposit Boxes VM600P Mounting plate VM604P Steel plate for tack welding VM602P Recess mounting box 2 NX VM610P Floor mounting box VM603P Damp resistant mounting box VM651P Moveable mounting kit VM652P Keyhole protection kit VM653P Spacer for keyhole kit VM654P 8 conductor armed cable kit VM655P Tamper resistant metal junction box VT705P Remote test transmitter VT610P Hand held test unit VT611P Safe application test sensor Planning and Installation manual VV600 VV602Plus 3 FUNCTIONAL DESCRIPTION 3 1 The VV600Plus standard seismic detector The VV600Plus is a fully equipped seismic detector compatible with almost any commercially available security control panel without the need of any additional processing circuitry FUNCTIONAL DESCRIPTION OF THE VV600PLUS Test e ternal VVT Sn Spare pi S7 Spare 10 Test 9 Sabotage 8 Sabotage Alarmrelay 5 Alarmrelay 4 Testpoint 3 Alarm LED 2 9 15 VDC 14 Sensitivity 3 1 1 Sensor element The VV600Plus is sensing the structural vibrations caused by an attack against the protected surface A piezo electric sensor converts the seismic signal into an electric signal This signal is th
3. ARITECR VV600 VV602Plus Vault Protection System Planning and Installation manual VV600Plus English version Revision 1A September 2000 Aritech is a division of InterlogiX B V Copyright InterlogiX B V 2000 All rights reserved No part of this publication may be reproduced transmitted stored in a retrieval system or transmitted in any form or by any means electronic photocopying recording or otherwise without the prior written permission of InterlogiX B V InterlogiX B V reserve the right to change information without notice CONTENTS 1 General infOrmatiOn cccseeeceeeesseeeeeeeeneneeeeaesenaeeenseeeeeeeeeaaaeseseaeenseeeneeeeseaesaseaeeasneeeseesaeensnaeees 3 a ADPIC e e YE 3 ENE ln eril ak Me Yi e e e terrence A eceverrer tener tree 4 13 Detecting and Testing cccccceccssceceeeseceeeeeeeeeeeeneeeeeeesaeeeeeesaseeeeaeeeeeeseneeeeeseeaeeeeneeeeeeeneaes 4 1 3 1 Thedetectionfunction aaa 4 13 2 The teSting SySteM senli akel eek ea silis bim sele sellni yea gemis 5 154 Features of the System s1 041 gente ina sale mml esma Geli imi e ek sil areata anaes 5 2 Basic Equipment of the VV600Plus System 1 001000020 01mm annen aa 6 2 1 Systeemcomponenis 1mm 6 3 Functional description vvm 400xv0m00000renne erener aramma a anammaaanammaaanammaaanamma mana mannanna 7 3 1 The VV600Plus standardseismi
4. Gata alata 10 4 1 1 Electric motors transformers fans airconditionels 10 44 2 Water piping oceanie ee ani i ee i eae 10 4 1 3 WltraSound detectors ms iie shcteeteteeeesceeteetaddevke eel sai elsi gi elli eee tees 10 4 1 4 BIS ner st feted di lee senle mala ba solak e i gali yla ie tates A E lke 10 4 1 5 FU e E EEEE TEE ted Cav bonne SAR amal iman Gar andrea cates 10 4 2 Detection range of the VV6O0 GOPPUS A A gt gt rnant 10 4 2 1 Thevaultorsafesensitiviytest 11 4 3 Planing a vault pr techon sn ears aen e UE EAEE IEEE EA AERA 12 4 4 Planning safe document cabinet and filing cabinet protection 13 4 4 1 Detectorsmountedinsidethesafe nnne 13 4 4 2 Detectorsmountedontheoutsideofthesafe 13 4 4 3 Filingcabinels iman ea adi elli ante bl 14 4 5 Planning the protection of an automatic teller machine ATM and a night deposit box 14 45 1 o Automatictellermachine AA A MAMAMAemememeZele lZZ I I m gt 14 4 5 2 Nightsafedepositbox eee 15 4 6 Planningig lderliMeS e ss ere ksa iade ea asa E sl Dae ileri di beledi pla A basi 15 5 installatlori 51 11111 10 inme san m yasan Bana kasaya anan sn sunusu daya bn klana an sko Sa 16 5 1 Generalinstructonsforsystemcomponenis nsen nsen
5. Mounted on the key hole protection plate VM652P close to the lock see 5 5 4 e With the movable mounting kit VM651P mount the detector in such way that the cable prevents opening the door when the detector is on the night position plate see 5 5 3 Although the detectors are better protected when mounted on the inside detectors mounted on the outside will have a deterring effect The VM651P and VM652P have the advantage of forcing the staff to handle the alarm installation properly It prevents the staff forgetting to remove keys or properly closing the safe doors Planning and Installation manual VV600 VV602Plus 13 4 4 3 Filing cabinets Normally the lock is placed on one side of the upper drawer on the front We therefore recommend to use one detector placed on the side of the cabinet close to the lock If special high security on one drawer is required we recommend to use the movable mounting kit VM651P on that drawer Mount the night position plate on the drawer and the day position plate on the side together with the junction box VM655P Use cable kit VM654P 4 5 Planning the protection of an automatic teller machine ATM and a night deposit box For both units we recommend the use of VV602Plus which is specially adapted to handle the noise created when the units are in operation We recommend to have one unit on the safe body and one unit on the door fy If you want to mount a detector on a light weight safe we
6. One potential free normally closed contact opening in alarm e One open collector transistor output going out of conductive mode upon alarm condition The transistor is being protected against short circuit with a series resistor Planning and Installation manual VV600 VV602Plus 3 2 The VV602Plus ATM seismic detector The Aritech VV602Plus detector is a seismic detector capable of detecting vibrations from an attack on an automatic teller machine ATM or night safe deposit box to which it is attached but still disregarding the vibrations created by the normal operation of the protected object FUNCTIONAL DESCRIPTION OF THE VV602PLUS Test e VT Internal V Sus E Sensitivity 3 2 1 Sensor element As in VV600Plus 3 2 2 The low integrating channel The low integrating channel looks at the low amplitude long duration signals This integrating channel is inhibited until the signal amplitude reaches a certain pre set level Upon reaching this amplitude level the signal is further processed and integrated At the same time a timer is started As long as the signal is constantly available the timer will run upon an interruption of the signal the timer will reset the channel to inhibited state after a pre set time 3 2 3 The high integrating channel To prevent signals from the night safe or the ATM from disturbing the VV602Plus upon the first appearance of high amplitude signals these si
7. actual tester is designated VT705P and is mounted inside the detector cover The tester only consists of a signal generator The electronics to generate the test signal is incorporated in the detector This gives a very simple and cost efficient test transmitter that is very easy to install 1 4 Features of the System e Will detect all known methods of attack against vaults safes ATM s etc e Compact and unobtrusive design using advanced microelectronics e Compatible with virtually all control units e Each seismic detector has full processing capability e Sensitivity adjustment available over a wide range e Unique advanced signal processing differentiates between ambient noise and real attacks e Unique test system using a self contained test transmitter in each detector e Three analysing channels e Counting circuit effectively suppress false alarms but maintaining best detection capability e Full tamper protection e Wide operating temperature range facilitates application in severe environments e Approved by VdS and many other approval bodies e Calibrated and easily adjustable sensitivity setting to adapt to various applications e The detectors intergration level can be measured with a Voltmeter on connection no 4 e Full range of accessories enables a wide range of applications to suit any requirements Planning and Installation manual VV600 VV602Plus 5 2 BASIC EQUIPMENT OF THE VV600PLUS SYSTEM
8. mounted on the protected object inside the detector housing There are two possiblitities for testing 1 Test disabled ex factory setting 2 nternal test of the detector s electronics Position jumper between connection 1 and 2 3 Function test of the detector and its physical contact with the protected object Position connector from test transmitter VT705P between connection 2 and 3 Test disabled Internal test Functional test ex factory setting 1 i 1 1 2 Jm 2 24 VT705P 3 m 3 m 3 a Test Transmitter 7 2 Wiring and commissioning The VT705P shall be mounted inside the detector see illustration under 5 4 1 The VT705P is connected over a 2 Pole plug to the detector Planning and Installation manual VV600 VV602Plus 29 ISO 9001 EESE C a 4466 1A
9. nenn 16 5 2 Mountingdirecilyontoasteelsurface AAMMAMAe e gt Zm m gt m m mm nanten 16 5 3 Mounting on steel and concrete using amounting plate 17 5 4 ThemountingplateVM6OOP AEE S EE 17 5 4 1 Mountinggonconcredte A AMA m m r EES 18 5 4 2 Mounting plate for welding VM6GOdP A AMA A m 19 5 5 Mountingofaccessories T E A 20 Planning and Installation manual VV600 VV602Plus 1 5 5 1 Recess mounting box VM6GO2PandVM610P 20 5 5 2 TheVvM6osPweatherprotetinbhMX M mm m 21 5 5 3 The movable mounting plate kit VM6X1P 22 5 5 4 oTheVM652Pkey holeprotectonk MMMMm e e e gt e e em m m gt m gt m gt m m 23 5 5 5 o TheVM654Parmouredcabekti AMAMA gt e gt Ze gt ZZZ Z AAA gt ZmI gt 23 5 5 6 The junction Dox VMB55P encanada aa a ia 24 Connecting the detector aa aaar las ll amasra ie kasi ada aaa ceceta sc a lama cheadh sacetsvasdctecdesitencedes 25 6 12 Cable requirement sisleri aptare an ee ais mayan aaa Ta aE A aaea yea 25 6 2 Wiringthedetectorintothesystem AMAMAMAMAMA e e e gt Zm gt gt 25 6 3 Controlandfunctiontest A e ewemem e e gt em gt em gt em gt em em gt e gt m gt mmm m uneia a piia hado N
10. to avoid placing ultrasound detectors closer than two meters from the protected surface It is useful to remember in this respect that it is not normally the detector itself picking up the ultrasound signals but mainly metal objects attached to the protected surface vault door steel cabinets etc 4 1 4 Bells May generate overtones in the frequency range of the detectors A simple solution is to suppress the overtones through application of a piece of tape on the bell 4 1 5 Human activity Normally people in close proximity to the protected area are not a problem It is impossible however to always predict their activities It is therefore advisable to keep a look out for floors running over the vault s ceiling stair ways adjacent to vaults and safes on concrete or marble floors In most cases carpeting or the application of insulation materials will solve any problems that may occur 4 2 Detection range of the VV600 602Plus The range of each installation depends on e The construction of the vault or safe e The vibration characteristics of the construction e The sensitivity required in each sensor e The natural vibrations and ambient noise level in the premises To determine these factors it is best to perform a field test The field test should include the following e Visual inspection of the vault or safe e A test to determine the existence of irregularities in the construction e A noise test e A plan to define t
11. 2P and VM610P For recess mounting of the VV600Plus in concrete the VM602P 610P recess mounting boxes are available Not only will this accessory give a nice and tidy installation but it also ensures a better coverage of the detector as it is anchored in the reinforcement bars of the concrete For the best results please follow the instructions below 1 Select the exact location where the VV600Plus units shall be mounted and make arrangements with the construction company to be on the construction site when the concrete casting shutters are being put up Do not forget floors and ceilings On the pre defined locations drill two 7 mm holes in the panel and mount the VM602P recess mounting box to the panel using the two M5 threaded pins enclosed with the VM602P Fasten the bracket in the tapered hole on the back of the mounting box Weld the bracket to the reinforcement bars in the wall After completion of the mounting of the VM602P to the wooden concrete shutter introduce the conduits into the holes on the sides of the mounting box Seal the holes around the conduit to prevent concrete from running into the mounting box Attaching the conduit to the reinforcement rods will prevent them from falling out during the casting process Save the cover plate Finger nut and pin bolt only used when pouring concrete When the casting is completed mount the VV600Plus detector on the VM600P mounting plate supplied with the
12. VM602P After completion of the installation and a successful test mount the cover plate with the enclosed screws Planning and Installation manual VV600 VV602Plus The VM610P floor mounting box is mounted in the same way as the VM602P 5 5 2 The VM603P weather protection box To protect the sensor from vandalism or high humidity use a VM603P protection box In an environment with high humidity and large variations in temperature it is recommended to mount a heat resistor a few Watt is sufficient 12 VAC 100 Ohm 2 W gives approx 1 5 W in the mounting box and drill a small drain hole in the lowest point of the box This will give a far better result then trying to seal the box with silicone which will only result in condensation problems Planning and Installation manual VV600 VV602Plus 21 5 5 3 The movable mounting plate kit VM651P The VM651P movable mounting kit is designed to enable movable day night mounting of VV600Plus and VV602Plus on vault and safe doors S 1 The night position plate shall be mounted close to the keyhole or the code wheel on the door the night position plate has a little tap in the right hand corner The best way to connect the VM651P is in series with the alarm relay of the detector This way the system can only be armed when the detector is in the night position 2 Mark the three mounting holes Drill tap holes for the three M4 bolts as described in ch
13. VV602Plus Mounting holes for Securitas SSD70 Mounting holes for Cerberus GM 31 35 550 560 Mounting hole for expansion plug or recess mounting box Mounting holes for Securitas 2000 Mounting hole for expansion plug to the test transmitter VT705P Mounting holes for accessories OTMUOW OF QE e v E A QPF Planning and Installation manual VV600 VV602Plus 17 5 4 1 Mounting on concrete In order to surface mount the VV600 602Plus on concrete a VM600P mounting plate is always required Please follow the instructions below carefully 1 Define the exact location of the VV600Plus and hold the VM600P mounting plate to the wall Mark the location of the hole for the expansion plug on the wall Drill a hole using a 9 mm drill The hole shall be at least 60 mm deep but if the surface finish is thicker than 10 mm drill deeper making sure at least 50 mm of the expansion plug is in the concrete itself You will need to use a longer bolt in this case Introduce the expansion plug into the hole you have just drilled and make sure that the top end of the plug does not stick out of the wall Note that only the supplied metal expander should be used If no test transmitter is used go to no 9 5 9 Rotate the mounting plate 1809 drill a marker hole in the concrete through the hole F 6 5 mm see ill A in the lower right hand corner Rotate the mounting
14. aRa ay 26 pae PTrOUble SMOOUING eeni A NEET OA 28 The Testsystem niipea ina en doya a pea aiia aiaa 29 Toto NT705P arerin i iol Me A N ee eae 29 7 2 Wirngandcommissioning Ei AEE 29 Planning and Installation manual VV600 VV602Plus 1 GENERAL INFORMATION 1 1 Application The Aritech VV600Plus Vault Protection System is a seismic system designed to detect attempts to break into vaults safes night deposit safes automatic teller machines and other enforced physical areas The detection technology used will react within seconds to all breaking and entering tools such as drill hammers side grinders acetylene cutters termic lances etc At the same time it allows for free movement around the protected area without the risk of creating false alarms The Aritech VV600Plus system has been field proven to be a very effective and reliable solution for safe vault and atuomatic teller machines protection It provides protection with the highest security level possible A complete range of accessories makes it application efficient and easy to use Of the many applications possible we mention e Banks and post offices Vaults safes coin cabinets automatic teller machines and night safe deposit boxes e Military defence Safes filing cabinets weapon stores early warning systems on gates and other physical barriers e Government buildings Archives safes document safes and computer data storage areas
15. annel is pre set and is not affected by the sensitivity setting of the integration channel 3 1 4 The explosion channel The explosion channel is set to detect very high amplitude and short duration signals as caused by explosives An alarm will immediately be triggered by the level detector when the pre set amplitude is detected The sensitivity is pre set and is not affected by the sensitivity setting of the integration channel 3 1 5 Power supply The supply voltage is first filtered and regulated thus providing insensitivity to electrical interference The internal voltage requirement is 6 V thus allowing the detector to operate in a broad voltage range The power supply features extremely good protection against high energy electrical surges The transient absorbers and the general design of the detector also give a very good protection against RFI for example from GSM cellphones 3 1 6 Sabotage protection Of course the VV600Plus seismic detector is equipped with comprehensive anti tamper provisions a tamper alarm is given when an attempt is made to e Pry the unit off the wall e Burn or weld the unit e lower the supply voltage below 7 5 V e Open the unit The detector is equipped with a solid state relay and consequently no protection against outside magnetic fields is necessary 3 1 7 Alarm output circuitry The circuitry may be activated by all three detection channels The alarm output provides two forms of alarm signals e
16. apter 5 2 Make sure the holes you drill in the door does not damage the locking mechanism Mount the night position plate using M4 bolts 4 Mount the junction box and day position plate together on the side of the safe or on the wall close to the detector in such a way that the cable prevents opening the door 5 On metal surface mount exactly as the night position plate On other surfaces than steel suitable screws and expanders have to be selected by the installer 6 Mount the VV600 602Plus detector on the base plate of the VM651P kit with the three screws supplied Planning and Installation manual VV600 VV602Plus 5 5 4 The VM652P key hole protection kit The key hole protection mounting plate VM652P has a stainless steel lever which in night position will cover the key hole and thereby stop the intruder from inserting explosives in the key hole At the same time the detector protects the safe or vault door from other kinds of attack The lock release button must always face up 1 VM652P can be mounted with the lever facing any direction 2 Select a location for the VM652P on the vault safe door Mounting holes A are used for the VM652P Drill tap mounting holes as described in chapter 5 2 Mount the VV600 602Plus detector on the VM652P cover plate and wire the detector according to the desired system configuration PEN 5 The micro switch inside the VM652P should preferably be wired into the detector
17. cdetector A gt m gt Z gt mm m 7 3AA Sensor element mel iyi ellerin Dil Lan ila alm aids 7 3 1 2 Theintegratonchamnel A MAMAMAMAmAme m gt e gt e e gt m gt Zm gt Z Zm gt m m gt gt mmmmm m 7 31 37 The counting channel sanli sekle say Kk gla ka b a eet aa asla 7 3 14 The explosion chantal asiria ir yk Sari sna yasa il ki tien Kan 8 3 15 POWER SUPDIY ex ssl EE kanl ayi eed ka Rl all lk T 8 3 1 6 Sabotageprotecilon a 8 3 1 Alarm outputcircuittiy E RR ANE RRE eaa 8 3 2 ThevVvV6o2PlusATMseismicdetector A A A A 9 3 2 1 Sensor elemeNt e a e as a aa eani AE iaa EE A a A ERER AES 9 3 2 2 o Thelowintegratingchamnel AAMMAMAMAMMA e gt m gt m gt Z gt Z gt Z gt Zm m m m m m 9 3 2 3 o Thehighintegratingchamnel AMMMAMMMAMA A e gt ZmA gt Z gt Zm m gt m 9 3 2 4 Theexplosionchannel EN aE ENAERE ETARE 9 3 2 5 KONEET Ei A E EEE PENRE AT E E A T E AE 9 3 2 6 SabotageprotecimM AMMAMAMmA e e eme e e gt m gt Z Z Z gt m Zm mmm m aai raddiant ordini denin oua dokani 9 32 74 Alatm outputcirGUlitiy A E E a E E E ime A ATE 9 4 Planning instructions 2 00 ceeeceeeeeee ee eeeeee seen neee seen nnee seen neee seen nee se en neee seen nneeseenseaeeeenseaeeeenseeeeeeseeennes 10 4 1 Pianina MONS sas 4 s euie cy a n Bakanla deresi aa dala a
18. do recommend you to contact Aritech for further information The VV602Plus can be mounted directly on the surface with the movable mounting kit VM651P or the key hole protection kit VM652P In any case we would recommend using the junction box VM655P and cable kit VM654P 4 5 1 Automatic teller machine Normally the best points for detectors are the door and as close to the dispenser opening as possible as these are the most likely points of attack See illustration I detectors Planning and Installation manual VV600 VV602Plus 4 5 2 Night safe deposit box Protection is planned exactly as a safe Attenuate the chute and the landing place with rubber insulating material to reduce the noise created by the falling cash boxes when deposited detectors 4 6 Planning guide lines Do s Do prepare a vault layout plan showing vault dimensions and locations of all equipment to be installed Do check that vault is constructed of monolithic concrete or concrete with steel liner or where constructed of concrete block or brick masonry must be bonded with Portland cement Do check that sensors are mounted directly to masonry or steel surface and that approved mounting hardware is used Do install at least one sensor on each wall as well as on the floor and ceiling Do protect vault door with sensor mounted as close as possible to side of door embedding it in door frame Do perfo
19. en analysed in three independent signal processing channels 3 1 2 The integration channel The integrating channel is designed to recognise low to medium amplitude signals with long duration like those caused by electric power tools or termic tools like a burning bar or acetylene torch The signal is first amplified in a preamplifier and filtered in a band pass filter only allowing relevant frequencies to pass After processing the signal is fed into an integrator which stores the incoming signals When a pre set level is reached the level detector triggers the alarm The sensitivity of this channel is set by adjusting the pre amplification level 3 1 3 The counting channel Planning and Installation manual VV600 VV602Plus The counting channel is designed to detect attacks with mechanical means like hydraulic jack and hammer and chisel It avoids having to set the integrating channel to high sensitivity and long integrator discharge times to cope with intermittent short duration mechanical attacks The incoming signal is amplified and pulse formed for a pre set time to avoid counting multiple bounces At the first incoming pulse the counter counts 1 and starts the timer If a second pulse is detected within 180 seconds the counter counts 2 and restarts the timer to look for a third pulse If a second pulse is not detected within 180 seconds the counter will be reset Five consecutive counts trigger the alarm The sensitivity of this ch
20. gnals are treated as if coming from the protected unit itself and are inhibited from reaching the integrator At the same time a timer is started After a short period of time the high integration channel timer runs out and if the signal still is present the signal is released for integration 3 2 4 The explosion channel As in VV600Plus 3 2 5 Power supply As in VV600Plus 3 2 6 Sabotage protection As in VV600Plus 3 2 7 Alarm output circuitry As in VV600Plus Planning and Installation manual VV600 VV602Plus 9 4 PLANNING INSTRUCTIONS 4 1 Planning limitations Although the Aritech seismic detectors are designed to provide a high level of immunity against nuisance alarm sources some precautions have to be observed Below we would like to mention some circumstances to preferably avoid 4 1 1 Electric motors transformers fans air conditioners Do not apply the detectors in close proximity of electrical devices creating mechanical vibrations in the protected structure If possible avoid mechanical contact between such devices and the protected surface or reduce the vibrations by using suitable insulating materials 4 1 2 Water piping The flow of water through piping when in mechanical contact with the protected structure emits a strong signal in the structure itself which may cause nuisance alarms 4 1 3 Ultrasound detectors May emit a signal that is within the frequency range of the detectors It is advisable
21. he detector and check for closed loop condition of the tamper loop Perform a functional test of both alarm and tamper signals according to panel specifications Planning and Installation manual VV600 VV602Plus 27 6 4 Trouble shooting Power and power supply OK False alarm Connect DC voltmeter between connection 2 and 4 Wait two minutes vv600Plus U lt 0 3 V U gt 3 0 V VV600Plus U gt 5 0V What s the voltage Causes are intermittent disturbances Detector malfunction Connect to pen recorder look for possible causes for disturbances Disturbances of detector from outside Cover detector with sound absorbing material No Voltage gt 0 3 lt 0 6V N Cause is strong air Cause is bourne sound between 3 30 kHz Ultrasound detector in the area Finish with chapter 6 3 Control and function testi vibrations in the protected surface Read planning instructions Type of alarm No alarm Test the detector with the test transmitter No the detector alarm within Detector malfunction Test the protected surface with the test transmitter VT705P Poor acoustic coupling with surface tighten screws on mounting No the detector alarm within 28 Planning and Installation manual VV600 VV602Plus 7 THE TESTSYSTEM 7 1 VT705P The VT705P is a testsystem consisting of a testgenerator inside the VV600 602Plus and a crystal unit which is
22. he location of each sensor As a guide line we have made a table showing the range as a function of the methods of attack and type of material in the construction of the protected surface 10 Planning and Installation manual VV600 VV602Plus DETECTION RANGE IN METERS OF THE VV600PLUS amp VV602PLUS Material Sensitivity Method of attack setting Termic Diamond Drilling lance disk Concrete K 35 4 Steel 1 Gmax 8 Brick 3 Concrete K 35 3 9 9 Steel 2 Gref 4 9 9 Brick 1 6 6 Concrete K 35 2 6 6 Steel 3 Gmin 2 6 6 Brick 4 4 Concrete K 35 1 5 5 Steel 4 1 5 5 Brick an 3 3 Concrete K 35 4 4 Steel 5 4 4 Brick 2 2 Zn The exact detection range can only be determined by practical tests on site This table is only to be regarded as a guide line and gives the detection radius in meters as a function of material attack method and selected sensitivity Please note that cracks and joints in the material may reduce the range Corners in the structure will reduce the range by approx 25 The above mentioned detection ranges for concrete are applicable on vaults and strong rooms cast according to most national norms for such structures 4 2 1 The vault or safe sensitivity test Where the surface of the vault or safe shows cracks gaps or has other irregularities perform a test to determine if the protection range of each sensor will be affected Additional detectors may be needed for full co
23. ld out plan will help in doing this Planning and Installation manual VV600 VV602Plus 4 4 Planning safe document cabinet and filing cabinet protection Most of the attacks against safes are aimed at the door and the locking mechanism It is therefore advisable to mount a detector on the door where the lock is situated The hinges my attenuate the signal transmission from the body to the door We therefore recommend to use one detector on the body of the safe as 4 4 1 Detectors mounted inside the safe Mount the first detector on a suitable space on the body of the safe normally this is at the front top side of the safe Mount the second detector on the inside of the door close to the hinges Use flexible cable kit VM654P together with the junction box VM655P Also add a magnetic contact on the door Cable outlet facilities are normally provided in new safes If not we recommend mounting the detectors on the outside 4 4 2 Detectors mounted on the outside of the safe We recommend a two detector layout with one detector on the side of the safe close to the hinges If you use the junction box VM655P and the steel cable kit VM654P you will have a safe and reliable installation The second detector can be mounted on the door in three different ways as illustrated e Mounted fixed close to the hinge providing a short distance to the junction box with the cable kit VM654P e
24. least about 1 80m high to keep clear from safes document cabinets and customer deposit boxes The range is reduced at joints between walls and floor and or ceiling if the reinforcement bars are not connected Joints severe cracking or doors should be regarded as insulating and additional detectors shall be applied on both sides of this irregularity As the vault door is regarded to be isolated from the walls by its hinges it is recommended to have one detector on or preferably inside the vault door New vault doors normally have cable channels inside the hinges to provide easy connection of the detector to the alarm system The detector can also be mounted on the outside of the vault door This gives a very efficient protection against torch cutting and a thermic lance as the vault door acts like a membrane and picks up the signal even before the attack on the surface has started The detector could be surface mounted either fixed directly on the surface or with the VM600P or VM604P mounting plates or it may be mounted on the movable plate VM651P Be careful when you drill into the vault door so that you don t damage the mechanical protection of the door If you are installing the detectors in an existing vault you can protect the walls on either side of the door with a detector mounted on the door frame Layout plan It is recommended to prepare a plan to define the location of each sensor and other components of the system A fo
25. plate back 180 and tighten the bolt see ill B Drill a hole using a 9 mm drill on the spot you marked before See point 2 above Introduce the expansion plug into the hole you have just drilled and make sure that the top end of the plug does not stick out of the wall Fix the VT705P test transmitter with the bolt provided with the plug Tighten the VT705P bolt Make sure that the VT705P does not touch the VM600P mounting plate It is recommended that all bolts are tightened at the first service after installation to compensate for inevitable material expansion in both wall and plug After completion of the mounting of the VM600P install the VV600Plus detector with the three supplied M4 screws Planning and Installation manual VV600 VV602Plus 5 4 2 Mounting plate for welding VM604P 1 Remove paint or other surface finish from the area where the VM604P will be mounted 2 Fixthe mounting plate into position on the surface and ensure that it can t move during the welding process 3 Weld the VM604P mounting plate to the surface First weld the points 1 2 3 4 then weld the seams 5 and 6 on the inside of the two slots see illustration 4 Mount the VV600 602Plus detector to the VM604P mounting plate using the three M4 screws supplied Planning and Installation manual VV600 VV602Plus 19 5 5 Mounting of accessories 20 5 5 1 Recess mounting box VM60
26. quirements The wiring of VV600Plus detectors reguires the following cable layout Number of Leads Features System common Per detector Power 2 Alarm 2 Tamper 2 Test LED 1 1 Testin 1 6 2 Wiring the detector into the system Bring the cable s to the detector feed them through the cable inlet cut them leaving approximately 10 cm of cable after the strain relief Remove the wire insulation with about 1 cm Wire the terminals according to wiring diagram below Illustration A Form A relay and illustration B Form C relay NC NO C 12V 0V LED ALARM RELAY TAMPER TEST INTERGRATOR SPARE SPARE INTERGRATOR SPARE LEVEL LEVEL RELAY TAMPER TEST 12V OV LED Planning and Installation manual VV600 VV602Plus 25 6 3 Control and function test 26 Check the proper mounting of the detector the VT705P and the cabling around them Check the proper wiring of the system preferably against a wiring diagram Apply power to the detector Perform the following tests Press the front of the VT610P hand tester against the protected surface at the fringe of the expected coverage area Press the button A buzzing sound will be heard The generated frequency is similar to the frequency of a termic lance attack The VV600Plus should gi
27. r e Felt pen e High speed steel drill diam 3 3 mm for M4 tap e High speed steel drill diam 4 2 mm for M5 tap e High speed steel drill diam 10 mm e Tap M4 to mount VV600Plus on steel surface e Oil to cool drill and tap 16 Planning and Installation manual VV600 VV602Plus 1 Define the exact location of the VV600Plus Using the felt pen mark the location of the 3 threaded mounting holes Use the mounting plate VM600P as a template and use a centre punch for exact location of the drill holes 2 Drill three holes using a 3 3 mm diam drill as deep as the steel surface will allow Thread the holes with a M4 tap Remove burrs with a 10 mm drill bit Mount the detector to the steel surface using the three M4 screws supplied Oy OY w If a VT705P test transmitter is used it can be mounted in the detector s right hand bottom corner see illustration on previous page 5 3 Mounting on steel and concrete using a mounting plate In the following cases you should use the VM600P or VM604P mounting plates e Always use the VM600P mounting plate for surface mounting on concrete e Use the VM604P welding mounting plate when drilling in the protected steel surface is impractical or impossible e Use the VM600P mounting plate when replacing Securitas SSD70 SSD 2000 SSD 4000 or Cerberus GM 31 35 36 550 560 5 4 The mounting plate VM600P A Mounting holes for VV600Plus amp
28. rm drill tests whenever possible on the outside of the vault Do apply silicone sealant around all openings of sensor cover screw heads and cable port after surface mounting sensor on floor Dont s Don t assume that covered concrete walls are free of cracks loose mortar or other irregularities Don t install sensors permanently before determining sensitivity settings and ambient noise level Don t install sensor on cinder block or other unproved masonry surface without contacting Aritech Don t mount sensor on rough surfaces sand all surfaces Don t allow test signal transmitter to make contact with mounting plate or sensor on mansonry installaiton Planning and Installation manual VV600 VV602Plus 15 5 NSTALLATION 5 1 General instructions for system components The VV600Plus and VV602Plus seismic detectors have cast zinc housing with the outside dimensions of 101 x 81 x 28 mm and a weight of 380 g By removing the screw holding the cover to the chassi gives access to e Mounting holes e Terminal e Sensitivity setting e Mounting space for testtransmitter VT705P e Tamper switch 5 2 Mounting directly onto a steel surface In most cases it is advisable to mount the detector directly onto a steel surface using the bolts provided and threaded holes which you will have to make For mounting the following tools are recommended e Mounting plate VM6OOP used as drill template e Electric drill hamme
29. s alarm loop to inhibit arming the alarm system if the keyhole protection lever is not in the protected position 6 The location of the lever can be changed if necessary To open the mounting plate and re position the lever the centre screw B in the illustration has to be removed 5 5 5 The VM654P armoured cable kit The armoured cable kit is designed to be used as a protective transfer from the door of a safe or vault to the body or wall Preferably it should be used together with the junction box VM655P The VM654P includes the following items e 8corecable white e Flexible stainless steel conduit e Protective ferrules e Cable straps e Plastic insert for double conduit The protective ferrules are used on the two ends of the steel conduit to protect the cable from the sharp edges The cable straps are used to secure the conduit in the VV600Plus or VV602Plus Planning and Installation manual VV600 VV602Plus 23 24 5 5 6 The junction box VM655P The VM655P is a well protected junction box It has a steel insert in the lid to protect it from drilling and a tamper contact to protect it from being opened The junction box has two terminal blocks with a total of 26 terminal two of which are used for the tamper switch and one for the screen to the base There is a plastic strap for strain relief for the cable and flexible conduit Planning and Installation manual VV600 VV602Plus 6 CONNECTING THE DETECTOR 6 1 Cable re
30. te signals with low amplitude and a long signal duration In the Functional description therefore you will find that different analysing channels deal with different types of signals in the Aritech VV600Plus System The application of surface mount technology in the actual sensor device itself has enabled the incorporation of complex circuits in a small housing thus providing unobtrusive aesthetically pleasing detectors without operational trade offs 1 3 Detecting and Testing The Aritech VV600Plus System consists of two main system functions which in close co operation guarantee an extremely high security level e o the detecting function e the testing function 1 3 1 The detection function The core of the Aritech VV600Plus System is the vibration detectors VV600Plus and VV602Plus Each VV600 602Plus seismic detector is a fully equipped vibration detector This means that all necessary processing electronics is incorporated within each VV600 602Plus unit Each such unit is ready to co operate with almost any control panel presently available No intermediate signal processing is necessary no vulnerable slave microphones are used The VV600Plus utilises the most advanced microelectronic processing circuits to reduce the risk of false alarms while maintaining the highest detection level The unique counting channel that is featured on the VV600Plus allow higher sensitivity settings on safe and document cabinets without generating n
31. uisance alarms from ambient noise It will also detect attacks with hammers sledgehammers crowbars and hydraulic jacks at a very early stage The VV602Plus model is used to protect night deposit safes and automatic teller machines ATM s The counting channel has been omitted in Planning and Installation manual VV600 VV602Plus the VV602Plus and replaced by two integrating channels to cope with the knocking sound of the cassettes being deposited in the night deposit safe and the pay out procedure in ATM s which may otherwise generate nuisance alarms This adapted signal processing does however not affect the detection efficiency A full range of mounting accessories for different applications facilitates a wide range of mounting requirements 1 3 2 The testing system In order to provide the highest level of security a daily test of the function of all VV600Plus and VV602Plus detectors in a system is required Therefore the Aritech VV600Plus System features a full functional test system that may be operated in parallel with the detection system itself When activated the test system will test the following important functions the detection system e Proper acoustical connection between VV600 602Plus seismic detectors and the protected surface e Proper signal processing capability of circuits inside the VV600 602Plus seismic detectors e Proper functioning of alarm output circuitry of the VV600 602Plus seismic detectors The
32. ve an alarm within 30 seconds and the VV602Plus within 45 seconds Knock firmly with a hammer around the detector with two second intervals between blows After five blows the VV600Plus shall alarm To protect the surface from damage it is advised to use a small aluminium plate between hammer and surface This test simulates the attack with hammer and chisel and is only valid for VV600Plus Planning and Installation manual VV600 VV602Plus Give one powerful blow near the detector with a hammer Both VV600Plus and VV602Plus should give an alarm immediately This test simulates an attack with explosives Check up the background signal level in the detector to prevent nuisance alarm Connect a DC volt meter internal resistance 20 KOhm V or more to terminal 2 negative and terminal 4 positive Place the volt meter in the range around 3 V Put the sensitivity selector in the maximum sensitivity Gmax Make sure that all possible causes for vibrations in the protected area are present and operating Check the output voltage and take measures accordingly For VV600Plus For VV602Plus Measure 0 7 V OV None 14V 2V 2 5 V 3 5 V Reduce range remove source Alarm reduce range remove source Preferably you should try to remove the source of ambient noise instead of reducing the range A Do not forget to set the detector s sensibility at the right value Close the lid of t
33. verage For concrete block and brick construction perform the following test using an electric drill and a 6 mm carbide tipped drill bit For test on steel the test equipment VT610P and VT611P should be used 1 Locate any irregularity in the construction The mortar between bricks and blocks should be considered as irregularities Install a detector at one side of the suspected irregularity Wire the detector to power and alarm circuit Set sensitivity to Gmax a PEN Drill into the wall at a point equal to the protection radius R depending on the construction type as described in visual inspection section Check for an alarm 6 If an alarm does not occur assume that the irregularity limits the protection range of the detector Drill again closer to the sensor until an alarm occurs and identify where it happens 7 Take all irregularities into account when spacing detectors Additional detectors may be required a The separation between vault door and the frame will reguire an additional detector on the door to encounter a possible attenuation at this point Planning and Installation manual VV600 VV602Plus 11 4 3 Planning a vault protection As a general rule it is recommended to have one detector on each wall floor and ceiling inside the vault and one detector on or inside the vault door The detectors should be recess mounted with VM602P or surface mounted with the VM600P on the walls We recommend to mount them at
Download Pdf Manuals
Related Search
Related Contents
English E-flite UMX Habu 180 DF BNF 6.5 Inscription aux cours en ligne Copyright © All rights reserved.
Failed to retrieve file