Home
AIR CURTAINS INSTALLATION MANUAL
Contents
1. amping the fixed Decide the position with the mounting plate screws on the back of main body to remove the and pour cement into the bolt holes mounting plate CONC RETE 40 50mm MOUNTING PLATE PLASTIC PARTS 13 15 mm 4 1 3 When the cement has freeze fit the mounting 4 1 4 Install the main body plate use the washer and nut according to the Set the main body onto the upper end of following the mounting plate and clamp it as shown WASHER ZZ SPRING WASHER MOUNTING PIATE CA B Installing on the wooden wall 4 2 Fix the mounting plate in the proper 4 2 2 Same as the step 4 of A positions with tapping screw MOODEN SCREW MOUN TING PI ATE C Hanging from the ceiling 4 3 Remove the mounting plate from main body Same as step 5 1 1 MOUNTING PIATE FIXING SCREW 4 3 3 Set the mounting plate on the ceiling brackets and ensure safe amp fixing use the bolts attached to the ceiling brackets as Fig Using the ceiling brackets to hang from the ceiling the position of mounting plate can be adjusted in the limit of 100
2. mm 4 WASHER SPRING WASHER cv EE MAX 100mm MOUNTING PIATE D For above ceiling 4 4 1F1x the air curtain as in the procedure for installing on the concrete wall 4 4 2 Then pipe as right Fig Instructs 5 HEATED MODEL TECHNICAL PARAMETER Volt Heater Freq power de FIT 00 WRM10 4 3 2 Fixing ceiling brackets as Fig ro M PA SHER ow UJ S PRING ii NUT 4 3 4 Do the same as step A to install the main body Max air Air a N db A m s a m cct Eae ES LINE SIZE THREE PHASES 380V MAIN LINE A By C ND pE A e eTe MAIN LINE mm Do not operate the air curtain if there is a voltage overload BLUE BROWN RED RECEIVER 1C AR YYYYY B RECEIVER Ne I 0 com 3 ons HEATER com 2 Oone e L THERMAL CUT OUT m com one HEATER BROWN GREY BLUE WHITE THERMAL CUT OUT YELLOW ORANGE UT OUT YELLOW GREEN YELLOW GREEN NA B C py 6 OPERATION 6 1 Control by remote control a Press the ON OFF butt
3. on to turn on the unit The unit will automatically start in non heating mode at high speed A green light will be displayed on the receiver b Press the SPEED button to change the speed of the unit to high or low c FOR THREE PHASE UNIT Press the POWER button to operate the unit in heating mode at low power A red light will be displayed on the receiver Press the POWER button again and the unit will change from low power to medium power with two red lights displayed Again press the POWER button and the unit will change from medium power to high power with three red lights displayed Press the POWER button again and the unit will switch from heating mode to non heating mode The red lights displayed change to a single green light d When the unit operates in non heating mode press the ON OFF button to turn off the unit e When the unit operates in heating mode press the ON OFF button The unit switches to non heating mode at high speed The indication light turns to a green flicker light The unit will continue to operate in non heating mode for 3 minutes and then stop 6 2 Control by the control panel in the unit is the same function as 6 1 6 3 Overheat protection When the heater temperature overheats over 135 C heating mode will stop and switch to non heating mode automatically at the same time the indication light will change to green Once the heater temperature drops down below 135 C press the POWER button to c
4. ontinue working in heating mode 7 CAUTIONS a Use the unit at the rated voltage and frequency indicated on the nameplate b Please do not connect power supply until the machine is installed c Maintenance must be done every year d Never use petrol benzene thinner or any other such chemical for clearing the unit e Don t allow water or any substances enter the motor f When connected with power socket it is advisable to choose an appropriate plug If connected to a power source directly use a safety switch
5. warmtec AIR CURTAINS INSTALLATION MANUAL WRM06 WRMO08 WRM10 Thanks for purchasing this Air Curtain Please read these instructions carefully before use 1 PRODUCT INTRODUCTION As one of the new top class products for modern decoration air curtain is also matched with the air conditioner And it is installed at the entrances of supermarket theater meeting room hotel office room working shop and storeroom to prevent the dust mosquito and nocuous air and so on 2 IDENTIFICATION amp INSTALLATION DIMENSIONS A ww 900 3 INSTALLATION CAUTION Must follow the following asking when installing air curtain 3 Please install the unit in a sturdy place to avoid 3 2 Please install the unit inside the room the shaking and ensure its security because it maybe causes the wall becoming flexible or shaking and noise OUTDOOR 3 3 Don t install the unit too low no less than 2 3 3 4 Don t install the unit in a place where it is meter from the ground When the entrance is wider splashed by water exposed to excessive than the unit it is recommended to install two or steam explosive gas or corrosive gas more units in parallel In this case provide 20 40mm gaps between the units 4 INSTALLATION A Installing on the concrete wall 4 1 1 Removed the mounting plate 4 1 2 Fix the bolts in the proper position Remove the plastic parts uncl