1. FISHER ingfi IGFISHER www kingfisher com au Fiber Optic Test Equipment Manufacturer USER MANUAL Kl6101 OPTICAL PON METER MAS Pig e 2 i11 Batteries sooo o to a ERR PI IEEE 2 1 2 Avoid condensation eese esses 2 2 SHIPPING CONTENTS eeeeeeseeeeeeeene eene nennen 2 B lt SARBUY e 3 A APPLICATION wisicccciisicicsscsinescssceseesasscassecescacvesdsenssstusdecerssscvessseds 3 5 INSTRUMENT FEATUREG cccsseeecesseeeeesseeeeessseeeeeseeeeeeees 3 6 FUNCTIONS wisisciscscsccssvecscscectcstccnscctecsssccctsaractivdsadssvasssncevacssceseans 4 7 TECHNICAL SPECIFICATIONS eese 5 8 OPERATION nonncca ine uoa orsa eana aaa eoa ns e sr vani e rarae cu iun an 6 6 1 Turning On amp Off cites tre ti ise blade 6 8 2 Low Battery Warning sessssssssseseee eene nnne 6 8 3 Set Cancel Auto Off Function sss 7 8 4 Setting Ref Value o ei A ccvasccescisdsecstiveetiacsatesexiaresiads 7 8 5 Select preset threshold ccccccccccccsssssssscssecscessensssssessesesensaeees 7 8 6 Choosing ABM OF Wessie 8 8 7 Changing Language sssissssese eene enhn 8 8 8 Setting the Clock ssssssssssssss esee eite enne 8 6 9 History Data eee erede rae in ae red rash ange eroe 9 9 MAINTENANCE AND CALIBRATION e 10 9 1 General maintenance eeessessssesese ee
2. Manual KI 6101 Optical PON Power Meter Issue 1 July 2011 Page 2 of 10 FISHER ingfi IGFI ISH rr www kingfisher com au Fiber Optic Test Equipment Manufacturer 3 SAFETY Take appropriate eye safe precautions when handling live fibre These instruments contain no hazardous optical or electrical items When using this equipment optical safety precautions commensurate with the maximum available source power should be observed 4 APPLICATION The KI 6101 series Optical PON Power Meter is used for testing FTTX PON fiber optic communication systems Connecting KI 6101 PON power meter in line between OLT and ONT will allows simultaneous measurement of all PON signals voice data and video The KI6101 is a useful tool for both network engineers and maintenance operators 5 INSTRUMENT FEATURES 1310nm Setup the threshold for 1310 nm wavelength the 1310 LED shows Green Pass Red Failure Blue warning 1490nm Setup the threshold for 1490 nm wavelength the 1490 LED shows Green Pass Red Failure Blue warning 1550nm Setup the threshold for 1550 nm wavelength the 1550 LED shows Green Pass Red Failure Blue warning User Manual KI 6101 Optical PON Power Meter Issue 1 July 2011 Page 3 of 10 FISHER ingfi KPNGFISH ae www kingfisher com au Fiber Optic Test Equipment Manufacturer 1490nm ONT Port Figure 1 Kl6101 APC USB port PC communication ONT port Used for testing Char
3. e Temperature 25 70 C Dimensions 179 x 93 x 48 mm 7 05 x 3 66 x 1 89 Weight 0 5 kg 1 1 Ib User Manual KI 6101 Optical PON Power Meter Table 2 Issue 1 July 2011 Page 5 of 10 FISHER ingfi KINGFISHER www kingfisher com au Fiber Optic Test Equipment Manufacturer 8 OPERATION Up Enter Exit Down Menu Off Figure 2 Button functions 8 1 Turning On amp Off Turn On Press ON for 2 seconds Once the main menu is displayed the meter is in working mode Refer Figure 3 below 1310 I w 1490 7 aa LOW 1550nm LOW VIDEO 09 02 27 08 47 Figure 3 Main Menu Turn Off Press OFF for 2 seconds to turn instrument Off 8 2 Low Battery Warning The 4A symbol indicates low battery User Manual KI 6101 Optical PON Power Meter Issue 1 July 2011 Page 6 of 10 FISHER ingfi IGFI ISH rr www kingfisher com au Fiber Optic Test Equipment Manufacturer 8 3 Set Cancel Auto Off Function When the instrument is turned on it is defaulted to Auto Off mode if there s no operation for 10 minutes the instrument will switch off To cancel the Auto Off mode Press Menu Press Down to access ae page of the menu refer Figure 5 Highlight the System State and press Enter When displayed the symbol indicates that the meter is in Auto off mode Press Off to cancel Auto Off function The symbol will disappear 8 4 Setting Ref Value Press Menu and Press En
4. ep the instrument in a dry place avoid moisture 9 2 Recommended re calibration interval The recommended re calibration interval is 3 years excluding connector wear User Manual KI 6101 Optical PON Power Meter Issue 1 July 2011 Page 10 of 10
5. ge port Battery charging customer side OLT port Used for testing network side 6 FUNCTIONS Kl6101 Optical PON Power Meter will allow doing the following 1 Testthe three PON network wavelengths 1310 1490 and 1550 nm 2 Testthe 1310 nm burst mode signal 3 Setthe threshold value upload data and perform calibration using the KI 6101 management software 4 Save 1000 records and upload the records to the KI 6101 management software 5 Supply 10 threshold value groups for operator to choose 6 Menu Display 7 Auto shut Off On Cancel Auto backlit 8 Real time clock display User Manual KI 6101 Optical PON Power Meter Issue 1 July 2011 Page 4 of 10 GFISHER INTERNATIONAL Fiber Optic Test Equipment Manufacturer www kingfisher com au 7 TECHNICAL SPECIFICATIONS Standard Wavelength 1310 Up 1490 Down 1550 Down Pass zone nm 1260 1360 1470 1505 1535 1570 Power range dBm 40 10 Isolation 1310nm dB Isolation 1490nm dB Isolation 1550nm dB Uncertainty dB 0 5 linearity dB 0 1 Polarization Dependent Loss lt 10 25 dB Through Insertion Loss dB 1 5 Resolution 0 01dB Unit dBm W ___General Specification Display 128 64 lattices Battery 7 4V 2800mAH rechargeable Li battery continuous work to 120 hours Work Temperature 10 60 C Storag
6. language available for user to select 8 8 Setting the Clock Press Menu Press Down to access gne page of menu refer Figure 5 below User Manual KI 6101 Optical PON Power Meter Issue 1 July 2011 Page 8 of 10 GFISHER www kingfisher com au INTERNATIONAL Fiber Optic Test Equipment Manufacturer 5 Time Set 6 History data 7 System state Figure 5 Highlight Time Set and press Enter to set time Press Up or Down to select date and then press Enter Press Enter to scroll through the date and time Note The format of date is YY MM DD for time is HH MM 8 9 History Data Press Menu Press Down to access oe page of menu refer Figure 5 below Highlight History data and press Enter The instrument displays Data View view data Del Cur delete current data record Del All delete all data records Press Up or Down to access previously saved data User Manual KI 6101 Optical PON Power Meter Issue 1 July 2011 Page 9 of 10 GFISHER www kingfisher com au INTERNATIONAL Fiber Optic Test Equipment Manufacturer 9 MAINTENANCE AND CALIBRATION 9 1 General maintenance All optical adaptors are subject to wear and tear Kingfisher International recommends e To increase instrument connector lifetime keep the test cords connected to the instrument at all times e Keep test cords and adaptors clean at all times e Fit end caps to all connectors when not in use e Ke
7. ne nnne nnn nnn 10 9 2 Recommended re calibration interval 10 User Manual KI 6101 Optical PON Power Meter Issue 1 July 2011 Page 1 of 10 FISHER ingfi IGFI ISH rr www kingfisher com au Fiber Optic Test Equipment Manufacturer 1 WARRANTY Information in this manual is given in good faith for the benefit of the user It cannot be used as the basis for claims against Kingfisher International or its representatives if accidental damage or inconvenience results from use or attempted repair of the equipment This product is guaranteed against defective components and workmanship for a period of 1 year from the date of delivery unless specifically stated in the original purchase contract or agreement This warranty excludes optical connectors or incorrect use Opening the instrument will invalidate the warranty Liability is limited solely to repair of the equipment 1 1 Batteries The instrument uses an internal 7 4V rechargeable Lithium battery providing continuous operation for up to 120 hours 1 2 Avoid condensation The instrument is resistant to normal dust and moisture however it is not waterproof 2 SHIPPING CONTENTS Please contact us if you find anything missing after you open the instrument shipping package Description Quantity Kl6101 APC Carry Strap External power supply Manual Soft carry pouch Software CD USB cable Table 1 Standard contents c cl cl cl c User
8. ter to access the menu refer Figure 4 1 REF 2 Threshold 3 dBm W Language Figure 4 Highlight REF and press Enter Press Up or Down to highlight one of the 1310 1490 amp 1550 nm wavelengths and the instrument displays reference value in dBm and loss in dB for this wavelength 8 5 Select preset threshold To select threshold value Press Menu Highlight Threshold and press Enter Press Up or Down then press Enter to select a threshold User Manual KI 6101 Optical PON Power Meter Issue 1 July 2011 Page 7 of 10 FISHER ingfi IGFISHER www kingfisher com au Fiber Optic Test Equipment Manufacturer NOTE There are total of 10 preset thresholds which include Over Pass amp Fail for 1310 1490 amp 1550 nm and they can be set using Kl6101 management software Once modified a threshold value can be passed into instrument KI6101 PON Management SoftwareV1 0 KINGFISHER INTERNATIONAL File Setting About HO ONT 1310nm OLT 1490nm VIDEO 1550nm Over Pass Fail Over Pass Fail Over Pass Fail 1 00 3 00 6 00 1 00 3 00 6 00 1 00 3 00 8 00 8 6 Choosing dBm or W Press Menu Press Down to highlight dBm W and press Enter Press Up or Down to select dBm or xW and press Enter 8 7 Changing Language Press Menu Press Down to highlight Language then press Enter Note There are English amp Chinese