1. 24 SKS LM MM M AM Me MI 24 SENSO COM erzielen ETT T 25 FATAL e E EEE EEEE E S 27 Ways of alarm presentation a 27 LIST OF PROCESSING UNITS 906 35 Processing unit configuration 36 PLACE THE SENSOR u uu uy u u airo inner ESOUR TRE LR D RAN DSL RD L D LEES P PPP 38 VISUALIZATION NN 40 41 AFRGIIIIO IIZIjIiI 44 CONFIGURATION OPTIONS FILE SETTINGSI INI 46 BACKUP COPIES SAFETY OF DATA J U 47 ALARM INFORMATION BY E MAIL mmm mmn 48 ADMINISTRATOR OF RIGHTS U U U 49 Basic information System description LOGGISOFT software is an element the measurement data collection LOGGINET system produced by MIKSTER LOGGISOFT software is applied for reading and analising the data from the LOGGINET system Functional properties e Monitoring of current measurement values e Reviewing of the co
2. Create in this place the same conditions as during the normal work Follow the recommendations given in paragraph 2 Failure to adhere to those recommendations can cause periodic or temporary fading of the radio signal due to changes of the propagation parameters of radio waves and due to electrical noises 6 Set the radio sensor into the mode of checking the radio signal level In order to set the radio sensor into that mode the following actions are needed a press and hold the button on the sensor until both control lamps are lighting b introduce the sequence of 3 presses and then release the button c the sensor indicates being in the mode by blinking the upper control lamp 20 4 times second The sensor in the mode of checking the radio signal level tries to synchronise itself with the radio system The synchronisation process 15 signalled by frequent blinking of the upper control lamp 4 times per second The synchronisation signalling indicators only have sensors without built in LCD displays doesn t concern LGTHD R 01 and LGTD R 01 sensors 17 process is finished when the sensor establishes the communication with the radio system recording unit When the radio signal level allows for the communication with the system the sensor will change into the mode of indicating the signal level When the radio signal level is too low to establish the communication the sensor will be in the synchronisation mod
3. T A car a En Ps WE E k Lm T s n Logqinet Riadio installation Before you start please read remarks Logginet Radio is a measurement registration system which uses radio waves radia range in the band is determined buildings and structures standing in radio link way and may result in reduction of its range when installing all devices ensure that all antennas are placed vertically impraper installation may result in reduction of the range bars in windows iran grids large areas or concrete cause serious suppression of the radio waves Next gt gt lt lt Back The information screen will describe the main features of the selected system After familiarizing with all the information press Next Step 2 i Fam T dp cr a P LAL Fe sss Am T a k J Starting the installation Lagginet Radia Please follow and canfirm all the instructions 1 Connect LGRT recording unit with PC WARNING Please unplug LGRT power supply before you begin 2 Plug inthe LGRT power supply 3 Place the LGRT to its final location do not move the during installation process 4 Press INSTALL to start IHS TALL lt lt Back 11 The consecutive screen gives the list of actions which should be done prior to the beginning the installation procedure Each performed step should be marked in the check box and when all 3 are completed the INSTALL button should be pressed
4. function is also accessible from the Actions panel on the Main Screen when you click on the right hand button of the two button mouse in the working area addition of the selected sensor to the visual working area from the list of active sensors In the commercial version the added sensors can be dragged to any selected place in the working area by the mouse with the left hand button pressed Sensors list the function also accessible from the Actions panel of the Main Screen the display of all sensors logged in the system Add sensors the function also accessible from the Actions panel of the Main Screen this option is only accessible to the Adm user It activates the creator of sensors adding to the system Processing units list the function also accessible from the Actions panel of the Main Screen the list of all processing units in the system New processing unit the function also accessible from the Action panel of the Main Screen this option is only accessible to the Adm user Addition of the recording processing unit to the system Archive data archive management Creator of adding system elements this option is only accessible to the Adm user Addition of a system element Logginet RADIO cable processing unit or sensors without a processing unit The creator is activated automatically at the first start up of the system 3 Settings Loggisoft v2 09a File Tools Settings Service OFEN Configura
5. main screen The dialog box Access control will appear Log in x Enter your user name and password User name Password Change password Cancel 15 Radio sensors Installation According to the recommendations of the Creator of adding system elements selecting Logginet RADIO after the detection and configuration of the processing unit the procedure of adding radio sensors is approached Installation of those sensors begins by introducing the processing unit in the configuration state function e Adding sensors When this icon is selected the process of adding radio sensors begins Searching For the sensors serial number Searching far sensors Found sensors willbe added to the sensor list Sensors found 2 Close Radio processing unit confirms being in the configuration state by periodic blinking every second of a control lamp isl When the particular sensor is added to the system its serial number appears in the list Sensors found and the counter Number of sensors found is increased Radio Sensor Installation Procedure 1 Place the radio recording unit in the place of its final destination If the radio recording unit is to be finally installed on the wall it should be placed there The place for its location should be selected as far as possible from devices which might cause radio interference computers inverters electronic devices The distance fr
6. running on your computer You must shut the server down before you can run setup Choose to exit setup now it means that the InterBase server has already been installed In such case press OK and when the screen appears select Cancel and in the next dialog box Exit setup When the installation is completed the program will automatically activate itself In addition an icon of starting will be placed in the desktop name Loggisoft and program menu Start gt Programs gt Loggisoft gt Loggisoft Getting Started Log in x Enter your user name and password The system requires the user s verification After the installation the only user is Adm without a password This user has all the rights including the right to create other users of the system Main screen Loggisoft v2 09a Jt lt lt lt DD Logginet TS i Logginet we Logginet CLIPS Weje e io Main menu 1 File Loggiszoft Y2 File Tools Settings Service Open Save 5 Close Alts Open input of previously written settings background sensor settings etc Save writes current settings into a file Close logout from the program 2 Tools Loggisoft v2 09a File Tools Settings Service Place sensor Sensor list Add sensor Recording units New recording urit Archive Sistem element adding wizard Place sensor the
7. with the system the sensor will change into the mode of adding to the system When the radio signal level is too low to establish the communication with the system the sensor will be in the synchronisation mode for more than 30 seconds After that it will change into the mode of adding to the system The mode of adding to the system is indicated by periodic blinking of both control lamps 1 per second and stays like that until an automatic configuration of the sensor in the system is reached An approximate time of the configuration procedure is proportional to the number of all relay stations installed in the system and equals a approximately 4 to 10 seconds for the radio system without relay stations b approximately 4 x 1 number of stations installed in the system seconds for the radio system with relay stations The very fact that the sensor has been added to the system is indicated by a series of 20 impulses sent by the lower control lamp 59 with the frequency of 4 times per second The upper control lamp does not light during that time When the sensor has been added to the system it changes to the normal mode the upper control lamp blinks every 15 second NOTE when the sensor was properly added to the radio system it is ready for the installation on the very place from which is was being added to the system The installation performed in different place can cause fading of the radio communication with the sen
8. 98 Temperature unit Celsius Fahrenheit Hext sensor gt PEUT senso Two modes of adding sensors are possible 1 Adding of sensor at the new location the check box Substitute at the present location should be left marked and the name of the new location written in the field Supply the location if new ATTENTIONI If there are no sensors in the system the check box might be invisible and in such case no change of the location is possible The change of sensor in the particular place location this option can be applied when substituting sensors due to faults or defects etc Then the check box Substitute on the current location should be marked and the name of the location on which the change was made selected from the list box The new sensor will substitute the previous one it will inherit recording and setting in the working area but will change the type and serial number ATTENTION The previous sensor from the given location will be removed from the system 34 List of processing units Function Tools gt List of processing units or the List of processing units button from the Actions panel Recording units central unit LGDL COM S600 2 Central unit LGDL COM 19200 3 Recording unit LGRT Radia CONT 19200 It displays the list of processing units in the system Processing units of an nactive status are displayed in gray Radio processing units which time differs by mo
9. Loggisoft Service Manual HIC uE Sp z o o 41 250 Czeladz ul Wojkowicka 21 Tel 0 32 265 70 97 265 76 41 763 77 77 Fax 763 75 94 www mikster pl 2003 12 04 Contents BASIC INFORMATION errreeennnnnnn nnne nennen nnne nnne nnns 3 SYSTEM SPECIFICATION FUNCTIONAL PROPERTIES a IR me 3 SYSTEM REQUIREMENTS cccceccecccecceccccecccccccuecuecnecaecaueauecuecuecatecneanecueenteanesueeneeuneaneaneenes 3 PROGRAM INSTALLATION uuu cece nnn nnnm nnne ll aaa nnns 4 DATABASE EO dU cM IM IM doses piss IINE dated IR LU DR dM IM d MD dU UT ERSTE 4 GETTING STARTED l nnnm nnn nnne nn nnn nn nnn rra nrunas 6 ITI SG RE EN ors tI EAEN I IU Me aera LP a fs kaza ak 6 MAI MEND cce suns T i Better cca T L Meets u ss 7 60 7 sa AP a 4 View commercial version only 8 5 Service options only advanced administrator 9 CREATOR OF ADDING SYSTEM ELEMENTS a e IR eme re eres rrsan reae ia eria reas 10 i M ARE TIE Eo EIOS RES anus shana samasaa ae ie Deets Ste me 15 RADIO SENSORS INSTALLATION cccceccecceccccecceccccecccacecceceneccecuecnecteateaeeneeneenesnesnesneaneass 16 MAIN FUNCTIONS OF THE
10. R 4 COOLER 3 77 S S S E COOLER 2 S COOLER 4 S S E S ama s B OFFICE PC c PRODUCTION R relay station S radio sensor radio recording unit When sensors and relay stations are incorrectly arranged Fig 1 and 3 there is a high probability of the lack of communication between radio sensors and the whole radio system due to large distances on the path sensor relay station radio recording unit Figures 2 and 4 illustrate the correct arrangement of sensors and relay stations Special attention should be drawn to the location of relay stations near the center of radio sensors area when planning the work places for those devices 23 MAIN FUNCTIONS OF THE SYSTEM List of sensors Function Tools gt List of sensors or the List of sensors button from the Actions panel Humidity 1 Senzor 3845 2 Sensor 62968 0 Close Temperature alarm is inactive Basic information Advanced Alarms Hame Sensor 3845 Type LGTH R Maximum Address H5 485 0 Minimum 0 Registration freque 3 minute Humidity alarm is inactive in recording uni3845 Maximum Signal Dz Minimum Battery 0 Show alarms after 1 minutes The function causes the display of the list of sensors in the system Sensors of Inactive status are displayed in gray Icons of accessible functions are on the upper panel The sequence of sensor setting can be establis
11. Step 3 ASP OLIST SSC LAL TE Coid T y Searching for the right serial port COMT Erasing recording unit buffers PC system date checking i a 5 lf PC system date is not correct then press Date change else press Next Date change Hext gt gt lt lt Back The next screen shows the progress of the procedure Search for the proper RS port search for the port to which the processing unit Is connected Reset the bufor of the processing unit resetting the settings of the processing unit Checking the system date current date and time are displayed Their correctness should be checked if they are not correct we can achieve the adjustment by pressing the key Change of date ATTENTION The time compatibility is a very important element of the system since all the collected data will be referred to the date on the PC computer When all steps have been successfully completed the Next gt gt key should be pressed 12 Step 4 FEDS TOLLAL Central recording unit is installed correctly For convenience please write your own name Recording unit then press Next Hext gt gt After writing the name of the processing unit press Next gt gt Step 5 serial number Searching for sensors Found sensors willbe added to the sensor list a Sensors found 2 Close The consecutive screen describes the process of addin
12. ackground there is no bitmap in the background Colors commersial version only oetting the view of sensors in the working area Configuration Mouse left click to change color Tranparent labels 20 1 C 31 ansparent sensor mall Sensors Text E White Test background Blue 42 By clicking the left hand mouse key the measured values the color might be changed Transparent background of inscriptions concerns only sensors without a background Marking that check box causes measured values to be displayed directly on the background of working area of the main screen The marked option displays measured value in the black frame Signature color of the inscription with the name of the sensor Background signature color of the background under the inscription with the name of the sensor 43 Archive Archivisation of data increases the efficiency of the system by sliming down the database and exporting the collected data to the file which can be recorded e g on a CD plate Such data can be imported later to the archive for the review of the collected data Archive options are accessible from the main menu Tools gt Archive Archive Start date End date Remove recordings moved to the archive Close Available archives are listed dates present the time period from which the collected data are in the archive Accessible functions Creation of a ne
13. ands out above 20 the ceiling or metal construction slightly worse when the antenna is parallel to the wall All devices should be assembled in such a way that antennas are perpendicular towards the ground The other installation can diminish the radio range Certain objects such as window grids louvers cast iron nets large areas concrete etc are causing intensive damping of radio waves so when looking for the suitable place for sensor installation such objects should be avoided Plastics glass and wood do not damp significantly radio waves Examples of correct and incorrect radio sensors and relay stations placing 21 Plant 5 COOLER 2 5 1 PRODUCTION 1 S OFFICE PC WAREHOUSE 1 S WAREHOUSE 2 S COOLER 2 S COOLER 1 S PRODUCTION 1 S S WAREHOUSE 1 S WAREHOUSE 2 OFFICE PC R relay station 9 radio sensor radio recording unit 27 S S COOLER3 COOLER 4 PRODUCTION 2 S WAREHOUSE WAREHOUSE 4 S S COOLER3 COOLER 4 S S PRODUCTION 2 S S S WAREHOUSE WAREHOUSE 4 Plant 5 3 4 3 5 5 O S COOLER 2 S N COOLER 1 2 s s 2 8 S R OFFICE PC PRODUCTION c S COOLE
14. cursor the date and time of the last proper reading will be shown as a hint In addition the alarm is signaled by sound the standard PC loudspeaker This signal can be switched by the On Off alarm sound signal button Collected data list displays dialog box with the collected data list for the selected time period Date selection Recordings 15 09 00 n 27 m Cancel Before the display of the collected data the period of time for which the data are required must be given Field From denotes the beginning of the period day and hour from which the data should be displayed Field To informs about the end of the period The change of dates can be done in two ways Write year month and day directly in the date field Select the certain day from the calendar which is displayed after pressing 81 confirm the selected period the key must pressed The list of the collected data for the selected time period will then be displayed 28 Collected data list Recordings 04 01 19 14 09 00 04 01 20 15 15 00 04 01 19 14 10 00 04 01 19 14 15 00 04 01 19 14 20 00 04 01 19 14 25 00 04 01 19 14 30 00 04 01 19 14 35 00 04 01 19 14 40 00 04 01 19 14 45 00 04 01 19 14 50 00 04 01 19 14 55 00 04 01 19 15 00 00 04 01 19 15 05 00 04 01 19 15 10 00 04 01 19 15 15 00 Print collected data printout for the sensor When this function is selected the screen for setti
15. e for more than 30 5 After that it will change to the mode of showing the signal level The mode of checking the radio signal level is indicated by periodic blinking of the upper control lamp o 1 per second The lower control lamp lt p will indicate the radio signal level by sending series of light impulses from 1 to 8 The lack of any impulses means that there is no communication with the system and the lack of the radio range NOTE the period of repeating of the impulse series varies and depends on the number of relay stations already installed in the system In case of 1 to 3 stations the period is 4 seconds For more relay stations this period equals 1 number of stations Seconds 7 Find the suitable place for the sensor installation Holding the radio sensor by hand from the side of the sensor output keep it on the wall exactly at the height and in the place selected for the installation Then wait for at least two repetitions of the sequence of signal level indications If in the place selected for the final installation for the two consecutive periods of the signal level indication the sensor shows at least 3 light impulses proceed to the installation of the radio sensor paragraph 8 If in the place selected for the final installation for the two consecutive periods of the signal level indication the sensor shows less than 3 light impulses the location should be changed and the whole procedur
16. e of finding the proper place for the installation started from the very beginning If such place where the signal level is at least of 3 light impulses can not be found in the whole room then the new relay station should be added to the system paragraph 9 NOTE in exceptional cases an installation of the radio sensor at the level of 1 or 2 light impulses is allowed but one must consider frequent fading of the sensor communication with the system The final criterion if the selection of the place for an installation was the proper one is the fact that we managed to add the sensor to the system 8 Set the sensor into the mode of adding to the radio system 18 In order to achieve that setting has to a press and hold the button on the sensor until both control lamps light b introduce the sequence of 5 presses and then release the button c the sensor indicates its transition into the mode by blinking the upper T and lower Es control lamp with the frequencies of four times and one time per second respectively The sensor in the mode of adding to the system tries to synchronise itself with the radio system The synchronisation process is indicated by frequent blinking of the upper control lamp gt 4 times per second The synchronisation process is finished when the sensor establishes the communication with the radio system recording unit When the radio signal level allows for the communication
17. ery second setting time of the cyclic readout of sensors The automatic LGDL readout to be done every minuts setting time of the readout in the background of the LGDL processing unit it is important after marking the option Automatic collected data readout on the Action panel Working mode commercial version only Direct the application cooperates directly with the devices connected to the PC computer port Network the application downloads data via the access to the database of the netwok computer The name of the computer shoul be given in the field Server name Format means name of server computer gt lt access path to the server database e g KOMPUTEREK C PROGRAM FILES MIKSTER LOGGISOFT2 DATAnew gdb The standard access path is C PROGRAM FILES MIKSTER LOGGISOFT2 DATAnew gdb the installation path can be changing however the file data gdb is a constant element 41 Background commertial version only Enables setting the application background e g the layout of the factory Configuration e Change insparent sens v Grid Cancel Net marking of that option causes aligning to the net the sensors localised at the layout it facilitates placing sensors in even rows and columns When this option is not marked it allows the discretionary sensor location with the accuracy of one screen point Change selection of a graphic file bmp as a background of working area Without b
18. f doors should be marked Wykres Eek Czujnik 12 LS wageankty pomiarowe Pokazywa alarmowe Czas 2003 11 16 23 47 00 Temperatura 21 1 Typ wykresu oe Doc Wilona a Grubo linii 2 The state of the doors shows the process Visualisation Sensors placed on the working screen give additional information apart from the alarm signaling described in the Alarms chapter also in case of radio sensors When the mouse cursor is on the sensor the hint will be displayed Range Last read date 2003 05 351 14 12 52 5 0 9 B 100 In the seen above record part S 0 B 100 means that the signal level equals 0 and the state of battery is 100 40 In addition the signal level Range is presented as bargraph Green color indicates the level In the case presented above the strip is completely white since the range 5 0 The bargraph has also hint giving the percentage of the signal level Configuration Option Settings gt Program Configuration is accessible to the Adm user only Basic settings Configuration Monitoring measurement retreshing rate Sec Request data fram the recording unit rin f E show alarms after ode f Server Client Server name server zdatabazse path on serwer server c program filesuvniksterVogaisoaft2Zwatanew gdb General parameters The readout to be done ev
19. g mail and addresses at which alarm information should be sent Creator of adding system elements At the first start up The creator of adding system elements will be activated Proceeding according to the information given on the consecutive screens one can install the radio system cable processing unit and sensors connected directly to PC FFEOUFITSFFOLOAE TEC i dC ASSY Welcome We are very grateful for choosing our product To improve Logginet System elements installation automatic installer helps to choose the right options dont show next time Start installation Abort installation and start Loggisoft After selecting Start installation of Logginet elements a list of available choices of elements appears Add sensors iot ume T M Acn n Ps Ps Fe cls coh e sal Select sensars ta add Logginet RADIO sensors C Sensors connected to LGDL C CLIPS sensors C Sensors connected to PC Any number of options can be selected simultaneously ATTENTION If the Logginet Radio option is not accessible it means that the radio system has been 10 already installed make changes in that system must use function Add Sensors either from Tools menu or from the Actions panel The process of a radio system installation will be presented below as an example of the whole process of installation After marking the Logginet Radio check box press Next gt gt Step 1 m 1 it am
20. g radio sensors described also in this Manual in the paragraph Installation of radio sensors The process of searching for sensors will be activated When all devices have been successfully installed exit the search mode Close 13 Step 6 The creator will display the final report of installation aot L Acn F pe LAL UE sss a r u IWY Finished adding sensors to recording unit REPORT Installed Recording unit type LGRTO1 Name Recording unit Port COM CON Baud rate 19700 Temperature sensor LGTR 1 0 qty Temperature and Humidity sensors LGTHRO1 1 qty When the Next gt gt key is pressed the screen of changing data for sensors will appear Step 7 Add zenzor FPEM JE T f pf mr Fe Clerc Please customize the sensor location entering measuring point Cooler Freezer etc Sensor 3845 Type LGTHR 01 5 Measuring point Change measuring point identification Sensor 82968 Temperature unit w Celsius Fahrenheit Hext sensor Previous sensu When the recording frequency and the location of found elements is set the Installation process is completed 14 Logging in There are four levels of authority in the system The change of user causes gaining access to appropriate functions of the system In order to achieve that change the Login button should be pressed left corner at the bottom of the
21. he entry are displayed in the dialog box In order to set the current processing unit time the button Processing unit record should be pressed When this is done the same time as seen at Computer time should be displayed at Processing unit time The Processing unit readout button reads the current processing unit time and writes it in the field Processing unit time 37 Place the sensor This function is used for the visual presentation of sensors measurements in the working area It is accessible either from the main menu Tools gt Place the sensor or from the Place the sensor button from the Actions panel or after pressing the right hand mouse key within the working area in this case the added sensor will be put in the place indicated by the mouse cursor This function displays the list of available choises Sensor list Humidity 1 Sensor 3845 2 Sensor 8298 Sensor 3845 24 2 24 04 01 27 15 20 57 Close Basic information Advanced Alarms Hame Sensor 13845 Temperature alarm is active Type LGTH H Maximum 20 Address H5 485 Minimum 0 Registration freque 3 minute Humidity alarm is inactive Ho in recording uni3845 Signal 86 Battery 100 Show alarms after 1 minutes Maximum Minimum To select the sensor one must either mark it on the list and press the Select key Or press twice the left hand key on the mouse on the selected sensor The selected sensor will be added to the wor
22. hed by dragging the sensor to the selected position by the left hand button of the mouse Accessible options Details shows or hides the lower panel with the details 24 Q List of alarms list of alarms for the selected sensor in the chosen time period Alarms 04 01 26 15 09 00 04 01 27 15 09 00 DateTime Huri Legend m Value below minimum m Valle above maximum or trans error Q Sensor Configuration the option accessible to the Adm user only enables the change of settings for the selected sensor type transmission parameters alarms Sensor Configuration Sensor configuration I Sensor configuration Set temperature unit Set temperature unit Mame fSensor3845 3845 Mame Sensor Sensor 3848 v Active II E Read sensor Active E E Read sensor General properties Additional information Alarms sensor Type LGTHR 01 v Connected to Recording Unit Recording unit Centrai unit in recording unit 3845 ES Certified sensor Type LorH o2 ki Connected to Recording Unit Address FS 455 Port COMM Baud rate 9200 50 05 Registration frequency 25 Field definition Sensor name name enabling an identification of a sensor Active sensor sensor status Read automatically choosing of this option causes immediate cyclic readouts of the selected sens
23. ing the line into the receiving state default 10 Radio processing unit version if the software is to cooperate with the older version of processing unit software this parameter should be set to 0 default 1 Prefix this parameter should have the value of a localhost 46 Backup copies safety of data Creation of backup copies of data is recommended if possible every day or at least every week All program settings are written in the file datanew gdb This file is in the directory in which the Loggisoft is installed default c Program Files Mikster loggisoft2 In order to copy the file it is enough to archive it in any way e g zip rar and copy into the directory with the name allowing its further identification e g the date of an archive creation Retrieval of data from the copy means the substitution of the current file datanew gdb by the file previously archived 47 Alarm information E Mail The system enables sending information about an alarm occurrence by E Mail at the selected addresses Such information contains the name of the measurement point name of the sensor time type of alarm temperature humidity doors and the measured alarm value The configuration is being done via the option from the menu Service options gt Alarm information by E Mail m Send alarms via E Mail SMTP server SMTP server E mail address Jauest serwer com Port bs Password Test adem configurati
24. ing unit only saving current settings of the processing unit including the logged in sensors Restoring the processing unit settings radio processing unit only restoring previous settings of the processing unit 36 68 Schematic presentation of sensors and repeaters connections radio processing unit only displays the radio system diagram The list of sensors together with the track of linking with the processing unit and the list of repeaters is given Creation of the diagnostic data radio processing units only Formation of the diagnostic data needed in case of problems with the radio system This procedure can take several minutes As a result the file diagn zip is created which enables the full diagnosis of the system V List of sensors in the processing unit displays dialog box with the list of sensors connected to the selected processing unit functionality is the same as described in List of sensors When the communication test is successfully completed one has to enter the overlap Processing unit time in order to set the proper time in the radio processing unit Recording unit configuration Mame Recording unit Properties Date Time v Active date and time BU EET IS Date Time 04 01 27 15 20 48 Read trom the device Send Cancel The current PC computer time Computer time as well as the processing unit time at t
25. io sensors only the function enables checking how the radio sensor is linked to the processing unit the list of repeaters via which the sensor communicates with the processing unit is displayed Add sensors Function Tools gt Add sensors is also accessible from the Actions panel The creator of sensors adding is activated FJELLS TOLLAL TECC Oy elect sensors ta add C Logginet RADIO sensors C Sensors connected to LGDL C CLIPS sensors C Sensors connected to PC The creator enables adding new elements to the already existing ones If a particular option is not accessible it means that the relevant component of the system was not installed e g when the radio system is not installed the function of adding sensors to the radio system is not accessible In such case the creator should be closed and the required component installed by the option Tools Creator of adding system elements If the relevant function is accessible then by proceeding according to the creator recommendations we approach the search for sensors When new sensors are found the creator will display data of those sensors enabling their modification 33 A SPOLIST SSC TE clas cot Please customize the sensor location entering measuring point Cooler Freezer etc Sensor 3845 Type LGTHR 01 5 Measuring point Change measuring point identification Sensor 82
26. king area if this sensor is already on the diagram the relevant information will be displayed together with the question whether the setting of this sensor should be changed into the currently selected only in case when the selection was done by the right hand key of the mouse The sensor position can be stabilised by dragging by the mouse with its left hand key being pressed 38 In order to add the INDU controller into the Loggisoft program either the Service Options new sensor button or the keyboard shortcut Ctrl N should be selected Then the Sensor type LGADC followed by the RS 485 address Comm Port and the Transmission rate 9600 should be selected The frequency of recording we might set e g every 1 second After assigning the name to the new sensor we can start working Sensor configuration Set temperature unit Mame Iv Active Read sensor General properties Additional information larrns Certified sensor Leane m Connected to Recording Unit Address FS 485 Port COM Baud rate Y foo o0 HH MM Registration frequency In order to put the sensor on the program pulpit we click the right hand mouse button on Place sensor To see the collected data and the process cycle one has to click the right hand mouse button on the sensor and select Graph 39 To see state of doors the option Show the state o
27. lection of parameters to be included in the graph temperature left scale humidity right scale Perpendicular green dashed line indicates the nearest measurement point in relation to the mouse cursor Particular values from this point are displayed inside the frame Time Temperature Humidity 30 Additional option is the description of alarm zones If the current sample green line exceeds the alarm levels then by the right hand side button of the mouse the menu with option Alarm zone description is called which allows adding comments for the alarm state occurance Export to the textfile export of data to the textfile in a format suitable for the readout of collected data to a certain program E g for Excell the data are separated by semicolons H Alarm zones for the selected range this function allows description of the alarm zones The system will compile the list of alarm zones time intervals in which temperature or humidity values were outside the alarm levels Alarm range Sensor Start date End date Sensor 3845 04 01 19 11 50 00 04 01 20 07 30 00 Sensor 3845 04 01 20 07 35 00 04 01 20 08 05 00 04 01 20 10 30 00 Sensor 3845 04 01 20 08 10 00 Description To change the description of alarm zones either s icon should be selected the left hand button on the mouse should be pressed on the selected zone It is also possible to see collected data from the given zo
28. llation procedure the relay station should indicate the signal level not lower than 3 impulses b The relay station should be placed as close as possible to the place selected for the sensor installation c In case when the problem of too low radio signal concerns several sensors the location of the relay station should be close to the centre of the area where those sensors are positioned The procedure of adding the relay station is the same as for adding the radio sensor The relay station should have the power supply of 230V AC When the new relay station has been added to the radio system the process of adding radio sensors in the direct vicinity of that station should be repeated Addition of the relay station increases the radio signal level in the range area of that station 10 Final recommendations Placing the radio recording unit and sensors near the electric network conductors or water conduits can significantly lower the number of relay stations needed in the system The general rule of the radio range area is you hear me as you see thus if possible the radio recording unit and the sensors should in the vicinity of windows and open spaces e g in the attic and above large concrete and metal objects being in the path of the radio waves propagation If possible radio devices should be installed with the antenna being far way from walls and ceilings Optimal case is when the antenna st
29. llected data either as tables or on a graph e Collected data printouts tables and graphs System requirements Loggisoft works under the Windows operating system on type computers The required version of an operating system Windows 95B second edition Windows 98 Windows NT 4 0 SP3 Windows ME Windows 2000 Windows XP Minimum hardware requirements Computer with Pentium processor 32MB RAM 1 port RS232 free disc space for the installation approximately 30MB Recommended minimum 100MB of disc space for working TCPIP data transfer protocol is also required In case when the computer is connected to the network network card this protocol has already been installed otherwise it should be installed For WindowsNT 2000 XP systems an installation of Microsoft diagnostic loopback card is enough while for Windows 9x the connection must be defined in Dial Up networking and the discretionary IP Internet Protocol number assigned to the computer The screen setting in the Loggisoft program should be as follows DPI settings normal size 96 DPI Program Installation In order to install the program on computers with Windows Windows 2000 lub Windows XP system one must login as a user with administrative rights Loggisoft is prepared for work in Windows environment It is delivered on a CD plate To install the program the SETUP EXE located on CD plate in the main directory should be activated Whe
30. n the program has been installed the installation program will activate the database InterBase setup Database Setup InterBase Server setup Welcome to the InterBase Server setup program This program will install the InterBase Server and Client Far Windows on computer It iz strongly recommended that you exit all Windows programs before running this Setup program WARNING This program iz licensed under the InterBase Public License which gives certain specific rights and Impases certain responsibilities may distribute this program under the conditions described in the file license 1 Select the NEXT gt key and again NEXT gt on the consecutive screen 2 The license of the InterBase 6 0 Server will appear on the screen Press YES 3 InterBase component selection Select the components you wish install InterBase Server InterBase Client Command line tools Graphical tool Software development support Example programs Descriptio InterBase 32 bit multi user server D estinatio C5Proaram FilezBarland InterB ase Browse Available 446200 K Required 3930 lt Back Cancel 4 Installation option shown the consecutive screen Leave all parameters without any change and select the Install key If after pressing this key the following information is seen Setup has detected an InterBase Server
31. ne and to construct the graph of measurement points 3l Description Miel E4 Sensor Sensor 3845 From 04 01 19 11 50 00 To 04 01 20 07 30 00 Core shutdown cave Cancel Only alarm values limitation of displayed records to alarm samples only gt Recording progress radio sensors and CLIPS only accessible also by pressing the right hand mouse button on the sensor on screen the function displays information concerning the progress of suplementing collection of data by a radio sensor Hecordings pragress Sensor 3845 Recording unit contains registered values up to 04 01 21 11 24 00 Loggisoft downloaded registered values from 04 01 19 11 50 00 to 04 01 21 11 24 00 The first date Recording by the processing unit has been done up to supplies information concerning the collected data in the radio processing unit If that date 32 differs from the current time it means that not all the data from the sensor have been suplemented in the processing unit Loggisoft suplemented the collected data from to The range of dates Indicates to which moment the program supplemented data in the processing unit gt List of signal level radio sensors only preview of signal levels in the form of tables and graphs Signal levels will be saved only when the option Save signal levels is chosen from the Main Menu Sensor connection list of repeaters rad
32. ng the printing parameters will appear Select range 14 08 00 ni agn 01 27 E 15 15 00 All registered values C Min values C Average values C Max values Range of dates for analysis selection of time period to be covered by the printout Report type All samples all collected data from the selected time period are displayed 29 Average value average values for the selected period calculated for the chosen time intervals are displayed an interval is given in the field Information every minutes Minimum value minimum values for the selected period calculated for the chosen time intervals are displayed an interval is given in the field Information every minutes Maximum values maximum values for the selected period calculated for the chosen time intervals are displayed an interval is given in the field Information every minutes D Graph Graph of the collected data for the given sensor in the selected time period Show sample marks I Show alarms lines m DateZTime 04 01 19 19 15 00 Show door state 7 Tempsisiure emporium A7 Line width 2 Close amp Print preview Humidity Humidity 250 Show measurement points On Off drawing of measurement points on the graph Show alarm lines drawing lines of alarm levels red and blue dashed lines show alarm levels for the temperature and humidity respectively Graph type se
33. om the recording unit to the radio sensors should be as short as possible Large concrete or metal surfaces on the path of radio signals can considerably attenuate them 2 During the installation procedure create in the room the same conditions which are expected to be during the normal mode of the recording unit If e g during the normal operation the door to the room will be kept closed then during the installation procedure the door should be closed too The same 16 recommendation concerns large concrete and metal surfaces such as gates window grids louvers large metal screens etc All devices which might interfere with the operation of the radio recording unit should be switched on a computers b telephone switchboards c devices of internal computer network d microprocessor electronic equipment e inverters at the final load f all electric equipment used during the production process Failure to adhere to those recommendations can cause periodic or temporary fading of the radio signal due to changes in the propagation parameters of radio waves or due to electric noises 3 Set the radio recording unit LGRT into the configuration mode The configuration mode can be set from the Loggisoft program see the Loggisoft Instruction Manual and it will be signalled by the recording unit by blinking of a with the period of 1 s 4 Take the sensor to the place in which it will finally be located 5
34. on Use modem Connection Save Cancel Fields definition Send alarm information by E Mail marked check box means that the alarms will be signaled by E Mail Server of outgoing mail SMTP server s name of the outgoing mail E Mail address of a sender E Mail address from which information will be sent it has to be the proper address on the given server Port port for servicing the outgoing mail Password if a server requires the authorization the password should be given Test a trial of sending test information from the given address Overlap E Mail Addresses this is the place where addresses at which the information is to be sent should be written 48 Administrator tools The program Administrator tools is applied for managing the access to the system It Is accessible from the menu Service options gt Administrator tools Administrator First name Mame acim Type Administrator zaawansowany agin Login E Save ace The program enables defining of users and assigning them the proper level of rights Type Available levels are as follows 1 Operator a basic user has the right to activate the program and to monitor the state of devices Cannot introduce any changes in the system configuration 2 Administrator this user has the right of changing the system configuration adding sensors changing names alarm
35. operties Additional information Alarms Temperature Maximum 2 w Active Minimum F umidity Minimum b Show alarms after mintes Active Field definition Temperature alarm settings of the temperature alarm On Off indication if the alarm is to be active or not Lower limit minimum allovable temperature When the temperature reaches this value or lower the alarm will be activated automatically Upper limit maximum allovable temperature When the temperature reaches this value or higher the alarm will be activated automatically Humidity alarm for sensors only settings of the humidity alarm On Off indication if the alarm is to be active or not Lower limit minimum allovable humidity Upper limit maximum allovable humidity Show alarm after minuts informs how many minutes after the occurrance of the alarm state the alarm should be visually signaled 0 means immediate signalisation Ways of alarm presentation The program presents alarm states by changing the way of displaying the measured values in the diagram Temperature alarm temperature values flashing red yellow color Humidity alarm humidity values flashing red yellow color Lack of communication with the sensor temperature and humidity values displayed as flashing 27 Lack of current readings flashing sensor name When the sensor is indicated by the
36. or The results will be displayed in the upper part of the screen Configuration of the sensor instead of This option is used for checking the correctness of selected settings Sensor type the type of the selected sensor according to the producer s marking Linked to the processing unit means of communication with the sensor direct or via the processing unit RS 485 address for sensors without the processing unit only the address in the MODBUS network Port Comm for sensors without the processing unit only communication port Transmission velocity for sensors without processing unit only Recording every sampling time setting frequency of recording Processing unit for sensors connected to the processing unit only name of the processing unit to which the sensor is connected No in the processing unit for sensors connected to the processing unit only identification number of the devices in the processing unit for radio sensors this is a serial number Recording update for radio sensors only after selecting this function one must state the date from which onward the system will actuate the collected data lists saved in the processing unit These data will be updated in the background during the work of the program 26 Alarms Sensor configuration Chronology set Settemperature unit unit Mame Sensor 3885 3065 Active e Fead sensor General pr
37. re than 5 minutes from the PC computer time are displayed in red Icons of the accessible functions are on the upper panel Accessible options enables changes in settings of the selected processing units 35 Processing unit configuration this option accessible to the Adm user only Processing unit configuration Recording unit configuration 6008 900 Mame Recording unit Properties Date Time v Active Type LeRr Radio Address RS 485 f a Port COM Baud rate 9200 Communication Cancel M Field definition Processing unit name any name allowing to identify the processing unit in the system Processing unit active the status of the processing unit Processing unit type kind of a processing unit radio or cable RS 485 address the number of the device in the network for radio processing unit default 1 Comm Port the port to which the processing unit is connected Transmission rate transmission rate for the radio processing unit the transmission rate is 19200 as a standard Accessible functions Adding of sensors introduction of the processing unit into the configuration state Q Processing unit reset zeroing of settings cancels sensors from the processing unit memory Introduces the device into the mode of the researching for Sensors E ndm Loading the settings from the processing unit radio process
38. s etc 3 Service the same rights as an administrator and in addition the possibility of configurating sensors 4 Advanced administrator in addition to the rights of an administrator he is authorized to change users rights administrator to preview the events log and to configure the E Mail information 49
39. sor When the sensor is not added to the system in the time relevant to the procedure described it might mean that the signal level is too low Thus the change into the better location of the sensor is required 19 If regardless of several attempts of the sensor installation in places where the signal level is at least 3 impulses problems with adding will often repeat it might Indicate that there are some radio noises near the radio recording unit Thus the location of the radio recording unit should be changed see paragraph 2 to check if this eliminates the problem In case when the improvement is not significant the following solution can be applied a Changing the location of the radio recording unit for the place being outside of the alleged zone of radio noises e g removal of the recording unit and its connections from the room with computers and inverters b Addition of the relay station near the radio recording unit however also outside the alleged zone of radio noises c Installation of radio sensors at the higher signal level of the system e g 5 impulses 9 Adding the relay station to the radio system The new relay station should be added to the radio system only in case when too low radio signal makes it impossible to locate the radio sensor in the selected place of the installation The place for the relay station should be selected in such a way as to meet the following requirements a During the insta
40. tion Print settings Log radio level signal Program configuration option accessible to the Adm user only Configuration of program settings background colors readout time working mode Printout settings option accessible to the Adm user only Configuration of printout headers and footers Save signal levels makes possible saving signal levels of radio sensors ATTENTION after each start up this function is switched off 4 View commercial version only Loggisoft 2 093 File Tools Settings View Serice LI sa 2 Large sensors Small sensors Transparent sensors Large sensors measurement values on the background of large sensors omall sensors measurement values on the background of small sensors Without the background measurement values shown without the background numbers only 5 Options advanced administrator only v2 093 File Tools Settings Whew Service Events log OFEN E SAVE Administrator tools Send alarms via E Mail GSM Configuration New sensor Review of events log preview of changes introduced in the system configuration The date and the name of the user who introduced important changes into the system is recorded Administrator of rights creation and edition of users see paragraph Administrator of rights E Mail alarm information commercial version only setting of the server of the outgoin
41. w archive we are selecting the period of time for an archive Data are transfered from the current bases to the archive ones ATTENTION the archive data will no longer be accessible from the sensor level but only from the archive level The system hints that as the beginning of the new archive period the end of the last one should be taken Remove archive removes the selected archive from the archive database ATTENTION If the selected archive was not previously exported its data will be completely lost TJ Collected data list from an archive displays collected data contained in the selected archive 44 Alarm list from an archive displays recorded alarm events from the time period of the selected archive Export to a file export of the selected archive to the file files of the given by an operator name ATTENTION each archive consists of 5 files of the given name extended Igc Igw Igo 190 Import from a file imports archive from a file 45 Configuration options file Settings ini The file Settings ini is in the directory in which the application is installed Here in the Parameters section there are advanced options of the program They are as follows llesleep parameter essential for Windows8x and RS485 In case of Icommunication problems this parameter value can be changed It indicates time delay in milliseconds between sending data and switch