Home

OPERATORS MANUAL (Universal Receiver uRx

image

Contents

1. Outdoor Surveillance User Manual Universal Receiver uRx A Division of TRAP INTERNATIONAL C C OPERATORS MANUAL Universal Receiver uRx Introduction Congratulations on your purchase of a Roboguard Universal Receiver Installation and wiring The installer s manual is available for people wishing to do a self installation Be careful as unqualified people can damage the device at installation and this damage is not covered by our warranty General Operation The Universal Receiver uRx is used to remotely trigger the operation of electronic devices from Roboguard signals The uRx can be taught to respond to any particular roboguard radio message Once the uRx has learned a roboguard code every time it receives that radio message it will respond by triggering the connected device This connected device may be an alarm system a camera system a siren an SMS module in fact any device capable of being triggered by an electronic signal In the example above a uRx can be programmed to respond to a radio message from a Roboguard handheld remote This handheld remote can then be used as a panic button and the uRx can be used to operate an SMS module to send an sms call for help in response to the panic signal Another popular use will be to open a garage door Your installer must connect the uRx to a power source and to the device that you wish to trigger The installer must also configure the options on the uRx
2. clearly indicated on the unit The 2 way dip switch is used to configure the polarity SW1 and the Switch timing SW2 Another version the uRxL should be used for latching requirements The I O1 and I O2 terminals are not used in this device The raw data from the radio is also available at the connector on RXO for connection to keypads or other decoder devices The unit has 3 LEDs one displaying RF data one showing the output NC status and one used for showing the status of the unit which will vary its flash rate for different option settings Installation Position the uRx in a position suitable for the reception of radio signals from the intended source Check for radio interference by observing the flashing of the RF LED If the RF led is flashing brightly and continuously then you may have a problem with radio reception Confirm this by transmitting from a roboguard product to see how the RF led flashes for data reception Obviously the device to be triggered will need to be located closely Wiring Wire the uRx to 12V and OV ensuring the OV is common with the OV of the device to be switched Wire the data line or the trigger NC outputs as needed The NC output is an open collector low side driver capable of sinking 500mA continuously It can therefore be used to drive sirens relays etc Should it be used as a data output then a typ 1k pull up resistor will need to be used at the connected device Coding As y
3. ou require the unit to decode a radio message then you must teach the uRx the code of the roboguard event by placing the unit into learn mode and then transmitting the relevant signal The device is placed into learn mode by using a conductor like a screwdriver to short out the program pads on the PCB The program pads are located next to the letter B on the PCB in the area of the 2 way DIL switch The status led will now remain on until the device learns a valid roboguard code Transmit the desired code tamper remote or intruder The status led will reset back to flashing If the unit is powered up with the programming input shorted then the unit will erase all learned codes Configuration Place the DIL switches in the required positions as per the information in the connected device s installer manual and the table below TON Jor Function Output polarity Output trigger time Testing The installation must be tested for RF range and for correct triggering of the connected device upon transmission of the previously learned signal POLARITY TIMING uRx AND uRxL STATUS RF DATA OUTPUT sed No lt u GO Gee RF DATA OUT Not Used Not L OV 12V lector low side sinking 500mA ed via the h to be normally VE OF out or open circuit w Oo 0 emo SS any VE voltages directly to NC dt tiv 10 out PLEASE NOTE Do not connect NC is an open co iver capabl can be configu la
4. rity swit tive short rmally inacti int 2s CONTROLLED DEVICE d I p a ni w a o oS Q Z 2 im E o o like a Keypad and Universal Transmitter RX DATA IN Wiring Diagram Note that this manual is written for people who have an understanding of electrical systems and the interconnection thereof If you are not in this position then we advise you contact an installer as you may damage the product and void the Warranty
5. to correctly trigger the connected device and must marry the transmitter to the uRx through a learning process The uRx will flash its status LED at different flash rates depending on the configured options as set up by your installer Maintenance There are no user maintainable parts or considerations Support Properly installed Roboguards do not false alarm Ensure that your system is properly installed and configured Please visit www robogquard co za forum for online support Warranty All Roboguards systems carry a 2 year factory warranty a lifetime warranty against UV damage and the guards themselves carry a lifetime warranty against lightning damage Technical Details Dimensions 104 X 64 X 27 Mass 100g Current Consumption _ 25 MA UHF 433 92 MHz Required receiver Required Power Supply 12V DC Colour White Packing Contents Trap International CC PO BOX 38113 Point 4069 Durban South Africa sales roboguard co za www roboguard co za ROBOEUARE Outdoor Surveillance Installation Manual Introduction The uRx can be used as a data receiver and as a Roboguard Decoder It will learn ANY roboguard Signal ie tamper intruder remote and Autotest unlike the HQ and Keypad modules which only learn tamper signals Upon reception of the learned signal the uRx will trigger a connected device Note that the uRx does NOT supervise the radio link 12V OV RxData RXO and Trigger N C Pin outs are

Download Pdf Manuals

image

Related Search

Related Contents

Dakota Alert Inc. Portable Radio Multiple Use Radio Serice (MURS) Hand Held Transceiver User's Manual  installation guide and user manual  User Manual - nh  Ferngesteuerter 3,5-Kanal-Kampf-Hubschrauber „GH-35.fight“  Agilent Technologies 86100b Sprinkler User Manual  EGY-25LN  Reagents  Nokia 7710 Cell Phone User Manual  Optiheat economy_1-22e bis 1-33e  Acer 4410T Laptop User Manual  