Home
Installation Manual - Astal Security Technologies
Contents
1. To add a card user Method 1 1 1 Read card Zone 1 This is the fastest way to enter cards using ID 1 2 Read card Zone 2 number auto generation Cards can be added continuously without exiting pro gramming mode To add a card user Method 2 1 1 User ID number Read Card Zone 1 User This is the alternative way to enter cards using ID 1 2000 User ID Allocation In this method a User ID is 1 2 User ID number Read Card Zone 2 User allocated to a card Only one user ID can be allo ID 2001 2100 cated to a single card AAT Holding sp z 0 0 Wszelkie prawa zastrzezone 8 Integrated Access Controller Installation manual To add card user Method 3 1 0 User ID number Card number Add a series cards users Block Enrollment Card quantity The card number must be consecutive Card quantity is between 1 2000 This operation is only for Zone 1 EM Card the first 10 digits card number or last 8 digits card number on the card To delete a card user by card 2 0 ReadCard Note Users can be deleted continuously without The devices can automatically identify the card of Zone exiting from programming mode 1 or Zone 2 To delete a card user by user ID 2 0 User ID number This option can be used when a user has lost their card To delete a card user by Card number 2 0 Card number Users can be deleted continuously without exiting from programming mode Card and PIN mode 3 1 1 forZone1or3 2 1 for Zone
2. Installation Manual INTEGRATED ACCESS CONTROLLER KZ 700 U H se KaDe VERSION 1 0 pa Holding A Z 0 0 awska 431 02 801 Warszawa tel 22 546 05 46 faks 22 546 05 01 www aat pl Integrated Access Controller Installation manual CONTENTS BE Lat OC OM EE o 0 2 a A AAA AAA a a aaa O SE 4 3 Specifications yen kara ra kna awa SANA NA KEN GAK KANE OT OC Se 4 Controller installation Aerch eet nan A Aan Od 5 5 Controller wiring diagram EE 6 6 Detailed Programming Guide eek a enn anana renane nene 8 AAT Holding sp z 0 0 Wszelkie prawa zastrzezone 2 Integrated Access Controller Installation manual 1 Introduction KZ 700 U H Integrated access controller The KZ 700 U H is a dual relay access control with EM amp HID 125 KHz card reader It is suitable for mounting either indoor or outdoor in harsh environ ments It is housed in a strong sturdy and vandal proof zinc alloy electroplated case The electronics are fully potted so the KZ 700 U H is waterproof and con forms to IP68 The KZ 700 U H supports up to 2 100 users in a card 4 8 digits PIN card PIN option and additional 10 groups Duress PIN card The built in card reader sup ports both EM amp HID 125 KHz frequency cards tags The KZ 700 U H has many extra features including Duress PIN card block enrollment Wiegand 26 37 bits interface and backlight keypad etc These features make KZ 700 U H an ideal choice fo
3. 2 To Add a card and PIN user Add the card as for a card user The PIN is any 4 8 digits between 0000 amp Press to exit from the programming mode 99999999 with the exception of 1234 which is Then allocate the card a PIN as follows reserved Read card 1234 4 PIN PIN To change a PIN in card and PIN mode Method Read Card Old PIN New PIN 1 Note that this is done outside programming New PIN mode so the user can undertake this themselves To change a PIN in card and PIN mode Method User ID number Old PIN New PIN 2 New PIN Note that this is done outside programming mode so the user can undertake this themselves To delete a Card and PIN user just delete the 2 0 ReadCard or card 2 0 User ID number Card ONLY mode 3 1 0 forZone1or3 2 0 for Zone 2 To Add and Delete a card user The operating is the same as adding and deleting a card user in Card or PIN Mode O To delete All users To delete All users 2 0 0000 Note that this is a dangerous option so use with 2 1 0000 Delete ALL users of Zone 1 care 2 2 0000 Delete ALL users of Zone 2 To set card users by Manager card This operation is only for Zone 1 To add Card User by Manager Add Card Manager add card Read user card Manager add card Cards can be added continuously To delete Card User by Manager Delete Card Manager delete card Read user card Manager delete card Cards can be deleted continuously AAT Holding sp z 0 0 Wszelkie p
4. es on the wall for the screws and 1 hole for the cable Fix the back cover firmly on the wall with 4 flat head screws Thread the cable through the cable hole Attach the keypad to the back cover PCB connect diagram AAT Holding sp z 0 0 Wszelkie prawa zastrzezone 5 Integrated Access Controller Installation manual Red J ACEDC 12 24V DC 12 18V AC Regulated Power Input 12 24V DC 12 18V AC Regulated Power Input Request to Exit Button of Zone 1 Request to Exit Button of Zone 2 Wiegand Input Output D1 Deen DO Wiegand Input Output DO 1n4044 Electric Bolt Red amp Black Brown m Door status detectng Ve Yellow Exit button H Pyetowi acz a UE ALARM Green Alarm z White Black GND 12V AAT Holding sp z 0 0 Wszelkie prawa zastrze one Integrated Access Controller Installation manual Remarks The Zone 2 it can be used to operate the door bell when no need to operate a second door The wiring is connecting the door bell to NO2 and COM2 Press the reader will send out a switching signal to the door bell as long as you press the the door bell will continuous operate it will stop until you release the Connect the negative pole of the lock to NC is for Fail safe lock Connect the negative pole of the lock to NO is for Fail secure lock Relay operation Pulse mode and Toggle mode The relay on board can operate in Pulse Mode suitable for access cont
5. ny number between 2101 2110 TosetDuresscarduser O O To set Duress card user To add d b d d 1 3 readcard 1 read card 2 9 aqa a calc USeroy Teac cal The ID number is any number between 2101 2010 To add d b d b 1 3 user ID number card 9 AQA a card User by card number The ID number is any number between 2101 2010 To delete a card user As the same method of deleting common card user To delete All Duress users 2 3 0000 Note that this is a dangerous option so use with care Note User ID number must be any 4digits between 2101 2110 Duress PIN card must be unique should be distinguished from common PIN card When the Duress PIN card is the same with common PIN card they will become invalid in Duress and worked as common user function Wiegand Mode Setting KZ 700 U H supports Wiegand 26 37 both input and output It can be used as a reader or controller To Set Wiegand format 9 26 37 Default setting Wiegand 26 AAT Holding sp z 0 0 Wszelkie prawa zastrzezone 11 AIS a AAT Holding sp z 0 0 di via ul Putawska 431 02 801 Warszawa tel 22 546 05 46 faks 22 546 05 01 Warszawa e mail aat warszawa aat pl www aat pl
6. ory master code Note that to undertake the following programming the master user must be logged in To change the master code 0 New code New code The master code is any 6 digits Setting the working mode Set valid card or PIN users 1 2 ntry by card or PIN Factory default setting Set valid card and PIN users 1 Zone 1 1 Zone2 y by Card and PIN together 0 Zone 1 2 0 Zone2 ntry by Card only r 1 2 r 1 nt 3 3 E 3 3 E 3 3 E Set valid card ONLY Note When adding users if the Card or PIN user has been enrolled already you can not add it again to the same zone or the device will give a bleep as error But it is ok to enroll the same card or PIN for the zone 1 and zone 2 Card or PIN Mode Factory default setting 3 1 2 forZone1or3 2 2 for Zone 2 To add PIN users 1 1 User ID number PIN Zone 1 User ID 1 2000 1 2 User ID number PIN Zone 2 User ID 2001 2100 The PIN is any 4 8 digits between 0000 99999999 with the exception of 1234 which is reserved Users can be added continuously without exiting programming mode as follows 1 1 User ID number 1 PIN User ID number 2 PIN Zone 1 1 2 User ID number 1 PIN User ID number 2 PIN Zone 2 To delete PIN users 2 0 User ID number Users can be deleted continuously without exiting pro gramming mode To change the PIN of a PIN user User ID number Old PIN New PIN This step must be done out of programming New PIN mode
7. r door access not only for small shops and domestic households but also for commercial and industrial ap plications such as factories warehouses laboratories banks and prisons AAT Holding sp z 0 0 Wszelkie prawa zastrzezone 3 Integrated Access Controller Installation manual Features Waterproof conforms to IP68 Strong zinc alloy electroplated anti vandal case Dual relay operation 2 100 users amp 10 groups duress PIN card Zone 1 up to 2 000 PIN amp card holders Zone 2 up to 100 PIN amp card holders Relay of both zones can be programmed for 3 modes card PIN card PIN Read both 125KHz EM amp HID card PIN length 4 8 digits Pulse mode Toggle mode Wiegand 26 37 input amp output Can be worked as reader or controller Dual relay output for door opening door status detecting open door by button Card block enrollment With manager cards for adding or deleting card user easily Very low power consumption 25mA Backlight keypad Light and sound of keypad can be set Support door bell connection Zone 2 Built in light dependent resistor LDR for anti tamper Built in buzzer Red yellow green and blue LED display the working status 12 24V DC 12 18V AC AAT Holding sp z 0 0 Wszelkie prawa zastrzezone Integrated Access Controller Installation manual Specifications LU PAN AC Installation Remove the back cover from the keypad using the supplied security screw driver Drill 4 hol
8. rawa zastrzezone 9 Integrated Access Controller Installation manual Relay Setting Pulse mode Toggle mode Pulse mode Factory default Pulse mode Door relay time setting 4 1 1 99 Zone 1 4 2 1 99 Zone The door relay time is between 1 99 seconds the factory de Toggle mode 4 2 0 4 Zone2 Door Detecting Alarm Sound and Light Settings Door Open Detection Door Open Too Long DOTL warning When used with an optional magnetic contact or built in magnetic con tact of the lock if the door is opened normally but not closed after 1 minute the inside buzzer will beep auto matically to remind people to close the door and continue for 1 minute before switching off automatically Door Forced Open warning When used with an optional magnetic contact or built in magnetic contact of the lock if the door is opened by force or if the door is opened after 20 seconds of the electro mechanical lock not closed properly the inside buzzer and alarm output will both operate The Alarm Output time is adjustable between 0 3 minutes with the default being 1 minute Alarm output time To set the alarm output time 0 3 minutes 5 0 3 4 Factory default is 1 minute Door open detection setting To disable door open detection Factory default To enable door open detection Keypad Lockout 6 Alarm Output options If there are 10 invalid cards or 10 incorrect PIN numbers in a 10 minute period either the keypad will lockout for 10 min
9. rol or Toggle Mode suitable for arming disarming alarms switching lights ma chines etc Every time a valid tag card read or PIN input in Pulse Mode the relay will oper ate for the pre set relay pulse time Every time a valid tag card read or PIN input in Toggle Mode the relay changes state which will not turn back until read card or input PIN again Reset to Factory Default To reset to factory default power off press hold it and power on release it until hear two beeps and the LED shines in orange then read any two EM or HID cards the LED will turn in red means reset to factory default setting successful ly Of the two cards read the first one is Manager Add Card the second one is Manager Delete Card Remarks Reset to factory default the user s information is still retained Anti Tamper Alarm The KZ 700 U H uses a LDR light dependent resistor as an anti tamper alarm If the keypad is removed from the cover then the tamper alarm will operate Sound and Light indication Green Light Blue Light Buzzer Zonet unlock LL Bright _ _ ShortRing Zone unlock Le Off e Long Ring Exit from the programming mode iyi EECHER Operation failed Ll 3 Short Rings WEE AAT Holding sp z 0 0 Wszelkie prawa zastrzezone 7 Integrated Access Controller Installation manual Detailed Programming Guide User Settings To enter the programming mode Master code 888888 is the default fact
10. utes or the alarm will operate for 0 3 minutes depend ing on the option selected below Normal status No keypad lockout or alarm 7 0 Factory default factory default Light and Sound Setting To set keypad backlight 81 0 4 To disable keypad backlight 81 1 To enable keypad backlight Factory default To set LED 82 0 To disable the RED Led 82 1 To enable the RED Led Factory default To set Acoustic Signal 83 0 4 To disable the keypad tone The acoustic signal can be set on or off 83 1 To enable the keypad tone Factory default When on the device will give the voice when press the keys when off the device will be in silent AAT Holding sp z o o Wszelkie prawa zastrze one 10 Integrated Access Controller Installation manual Change Zone 2 to Door Bell When no need to operate a second door Zone 2 can be set to operate the Door Bell The wiring is connect ing the door bell to COM2 and NO2 Press the keypad will send the signal to the door bell Zone 2 84 0 Factory default Door bell 84 1 To remove the alarm Toreset the Door Forced Open warning Read valid card or Master Code Toreset the Door Open Too Long warning Close the door or Read valid card or Master Code Duress User Settings There are 10 groups Duress PIN card available When input Duress PIN card the door will open at the same time the output alarm operates As the same method of deleting common PIN user The ID number is a