Operating Instructions for Netter Electronic Timer Type AP 116
Contents
1. Ono O Attention igh Voltage Vorsicht Netzspannun 9 1 25f T iit gt M Direct voltage If direct voltage DC is applied to the terminals 1 and 2 direct voltage DC is also applied to the terminals 4 and 5 Alternating voltage lf alternating voltage AC is applied to the terminals 1 and 2 alternating voltage AC is also applied to the terminals 4 and 5 lf alternating voltage is applied the protective conductor PE must always be connected terminals 3 and 6 The voltage level of input and output voltage is always the same AC DC fuse 1 25 A slow blow Output strip terminals 4 6 AC or DC Power supply connection strip terminals 1 3 DC or AC Terminal strips Terminals 4 6 E a Ean os Terminals 1 3 2 3 PY ake why Ke NILIPE AC DC power supply DC AC R Ws F hae ks SSS POWER i102 N AC DC output DANGER ANT In standby mode the red LED flashes In the adjusting or operating mode the LED lights up continuously if active keys are touched The sensor keys react to slight touching not pressing In the adjusting mode you can switch between and Adjusting the duty time If the timer is switched off the outputs terminals 4 5 are de energized Touch the key ON OFF until the display is illuminated The electronic timer starts immediately with the stored time values Touch the key FN until two additional illuminated po
2. NV NetterVibration Operating Instructions for August 2012 Netter Electronic Timer BA No 1308E Type AP 116 Page 1 12 These operating instructions apply to Type AP 116 Netter GmbH www NetterVibration com Germany Fritz Ullmann StraBe 9 55252 Mainz Kastel Tel 49 6134 2901 0 Fax 49 6134 2901 33 info NetterVibration de Switzerland Poland Erlenweg 4 Al W Korfantego 195 17 4310 Rheintelden 40 153 Katowice Tel 41 61 8376200 Tel 48 32 2050947 Fax 41 61 8311291 Fax 48 32 2051572 info NetterVibration ch info NetterVibration pl Contents 1 GENERAL INFORMATION 2 SAFETY 3 TECHNICAL DATA 4 DESIGN AND FUNCTION 5 TRANSPORT AND STORAGE 6 INSTALLATION 6 1 Mounting the electronic timer 6 2 Electrical Connection 7 START UP OPERATION 10 8 MAINTENANCE SERVICE 11 9 TROUBLESHOOTING 11 10 WASTE DISPOSAL 12 11 ENCLOSURES 12 Scope of Delivery Check the packaging for possible signs of transport damage In the event of damage to the packaging check that the contents are complete and undamaged If there is any damage inform the shipping agent Compare the scope of the delivery with the delivery note The following instruction and warning symbols are used in these operating instructions DANGER AUTOMATIC START CAUTION DISCONNECT POW ER SUPPLY IMPORTANT ENVIRONMENTALLY FRIENDLY DISPOSAL refers to a possible risk which if not avoided can result in death or serious injury refe
3. points extinguish The outputs terminals 4 5 are deenergized while the pause is running for at electronic timer AP 116 the next cycle will always begin with the set lf following a voltage interruption power is again applied to the duty time DANGER When the timer is switched on the output is immediately energized 8 Maintenance Service em Please observe the safety regulations in chapter 2 when servic IMPORTANT ing the device lf the timer is continually subjected to regularly checked at least every 6 atmospheric influences the seal in the months for signs of porosity All other cover and the electric lines should be parts are maintenance free 9 Troubleshooting ATTENTION Troubleshooting of AP 116 electronic timer should only be conducted by DANGER 2 authorized specialist Fault Possible Causes Troubleshooting Check fuses and Replace fuse or connection cables connection cable doesn t start Power supiy oo tow cables Pp p Phase interruption Saa Check polarit Connect cable wires i i with correct polarity polarity reversed when Voltage drop under Check power supply Connect power operating in load connection supply correctly RUN Timer fails 11 10 Waste disposal Material specifications Electronic timer AP 116 over All devices can be disposed of through Netter GmbH ENVIRON i MENTALLY The applicable disposal prices are available upon request FRI
4. ENDLY DISPOSAL 11 Enclosures Enclosure s Additional information available Declaration of Conformity HS upon request Leaflet No 35 and much more 12
5. alist The specialist must work only with insulated tools which are suitable for the application Suitable supply cables should be used for the connection of the electronic timers AP 116 Cables and earthing conductors must be connected according to the respective regulations The conductors in the supply cable for connection of the AP 116 to the power CAUTION supply must be temperature resistant and have a sufficiently large cross section matching the used cable length The electric lines must be carefully routed It must be ensured that cables cannot be worn through by vibrating components lt should be checked that the electric lines and their connectors are in perfect working condition at regular intervals generally every six months DANGER Any faults which are discovered must be immediately remedied Protect cables from high temperatures lubricants and sharp edges At delivery the fuse is located in the socket The operating voltage for the electronic timer is also the supply voltage for the device to be controlled solenoid valve contactor vibrator motor etc Connection Unscrew the 4 cross head screws of the sensor cover Lift off the sensor cover The electronic timer can now be connected via the terminal strip The voltage is supplied via the power connection block 1 and 2 DC or AC terminal 3 PE AC The output voltage is applied to the terminals 4 and 5 AC or DC terminal 6 PE AC
6. d against reverse polarity 1 25 A at 24 V and max 40 C to lt 2A 20 C to 60 C The operating temperatures must not be exceeded or fallen short of IP 65 RFI suppressed 4 5mm to 10 mm Metric cable connectors 6 4 Design and Function The electronic timer consists of two basic components e Voltage supply with electronic switching unit and e Display unit with operating elements 5 Transport and Storage Check the packaging for possible signs of transport damage In the event The sequence begins with the duty time run which can be adjusted from 1 s to 99 h During this time the supply voltage is applied to the timer output When the duty time ends the pause time of 1 s to 99 h is running pause then the duty time etc The elapsed time is visible on the display The respective time digits are brightly illuminated when active Housing Sensor cover attachment RUN Duty time adjustment Duty time display PAUSE Pause time adjustment Pause time display increases the selected time value LED decreases the selected time value oO N OO A WD N Mounting bores Sensor cover 12 ON OFF Switch standby no disconnection import Of damage to the packaging check that the contents are complete and ANT undamaged If there is any damage inform the shipping agent The electronic timer is packed ready to install At delivery the fuse is located in the socket When transpo
7. ints appear in the display adjusting mode The outputs terminals 4 5 are de energized Touch the key and select the position to be adjusted seconds minutes or hours by actuating or the points will change To increase or decrease the time value actuate or and do not touch RUN If the required duty time has been adjusted it must be confirmed by touching again the key FN for at least 3 seconds The values are stored when the points extinguish The outputs terminals 4 5 are energized while the duty time is running 10 When switched on the AP 116 starts immediately with the stored time values The connected devices also start immediately LED 2 Y Adjusting the pause time If the timer is switched off the outputs terminals 4 5 are de energized Touch the key ON OFF until the display is illuminated The timer will start immediately with the stored time values Touch the key puse until two additional illuminated points appear in the display adjusting mode The outputs terminals 4 5 are de energized Touch the key and select the position to be adjusted seconds minutes or hours by actuating or the points will change To increase or decrease the time value actuate or without touching PAUSE If the required pause time has been adjusted it must be confirmed by touching again the key least 3 seconds The values are stored when the
8. lified Personnel Installation start up maintenance and fault correction of the electronic timer may only be carried out by authorised qualified personnel Handling the electronic timer always lies in the responsibility of the operator The electronic timer has no safety devices of its own 2 Safety Netter GmbH does not assume liability for damage or injury resulting from technical modifications to the product or failure to observe the instructions and warnings in this operating manual Live parts can cause severe or even deadly injury lf following a voltage interruption power is again applied to the power Supply connection the next cycle will always begin with the set duty time The output is immediately energized When working on the electronic timers they must be isolated from the mains supply To do so please proceed as follows 1 Switch off the electronic timer DISCONNECT MR POWER 2 Secure it against switching on SUPPLY 3 Make sure it is de energized 3 Technical Data Duty time RUN Pause time PAUSE Own consumption Operating voltage AC Switching current AC ANT Switching current DC Switching current DC Ambient temperature Protection Cable diameter Dimensions Exact to the second up to max 99h 59min 59s Exact to the second up to max 99h 59min 59s 2 VA in operation 0 25 VA standby 90 V to 240 V 1 25A Or Operating voltage DC 24 V 48 V 5 protecte
9. rs to a possible risk which if not avoided can result in death or serious injury refers to a possible risk which if not avoided can result in serious injury and or equipment damage refers to a possible risk which if not avoided can result in serious injury and or equipment damage note with especially useful information and tips refers to the obligation of an environmentally friendly disposal 1 General Information Netter Type AP 116 electronic timers comply with the directive for electro magnetic compatibility 2004 108 EC and the low volage directive 2006 95 EC Standards DIN EN 61010 1 and DIN EN 61326 1 have been particularly observed Electronic timers are used wherever a procedure needs to be time controlled Any other usage is considered to be improper AP 116 electronic timers are suitable for timed activation of electric external vibrators solenoid valves and motor overheating protection With these timers electric vibrators pneumatic vibrators pneumatic impactors and other drives can be switched on and off exactly to the second By selecting suitable pause times the operation of the vibrators is optimised drive energy can be saved and the noise level lowered Special features e Digital adjustment exact to the second e Dust and water splash protected e Protection type IP 65 radio interference suppression e Operation mode electronic non contact e Direct control Qua
10. rting electronic timers it should be ensured that they are not subjected to severe impacts or vibrations The units should be stored in a clean dry environment lf electronic timers are in storage for longer periods the temperature in the store room must not be below 20 C or above 40 C and the relative air humidity must not exceed 60 6 Installation During installation the safety regulations in chapter 2 and the accident prevention rules must be strictly observed The electronic timers have been manufactured in accordance with the current EC directives Installation start up and maintenance may only be carried out by WARNING authorised qualified personnel For installation and operation of the electronic timers the regulations and directions of the local engineering associations e g VDE and the known accident prevention rules have to be observed 6 1 Mounting the electronic timer AP 116 electronic timers can be mounted in any position The 4 bores 04 2 mm for attachment of the unit are accessible once the cover has been opened 6 2 Electrical Connection CAUTION Dimensions of the mounting bores 90 mm x 110 mm see chapter 3 Technical data The mounting surface must be even and level in order to avoid damaging of the housing The AP 116 must not be mounted or dismounted with voltage applied Electrical installation of the AP 116 electronic timer may only be performed by an authorized speci
Download Pdf Manuals
Related Search
Related Contents
L`abreuvoir : Comment mieux communiquer sur vos événements ? MX Component Version 3 Programming Manual 【FA404M/MXシリーズ取扱説明書】 E500 Camera Housing Instruction Manual 090223 Davy I-7540D FAQ Logitech F710 User's Manual Tascam CD-RW2000 Speaker System User Manual The SMART Way to Heat Your Pool INSTALLATION AND Kennedy III - ekomedical.pl テキスト読み上げ太郎 2 - 株式会社デネット パソコンソフト製品サイト Copyright © All rights reserved.