Home

OPERATING INSTRUCTIONS LG 39E Multi User Combogard

image

Contents

1. battery clip on general sale Black upper position red lower position When connected to the alarm equipment through the interlock device SP then the power supply is secured from this place e Change the manager code immediately e Do not use personal data birth date as a code e Keep the code from unauthorised use 1 x short signal enter confirmation 2 x short signal valid code entered 3 x short signal wrong code not accepted 6 x short signal remote disable blocked by the alarm equipment LED signal each 10sec 1 flashing blocking time after a wrong tries LED signal each 2sec Time delay before opening is running Alternate LED and acoustic signals Time window for opening is running A series of triple signals ca 3seconds Low battery Still possible ca 10 openings According to the battery capacity there may be also less signals therefore the battery change should be made also in case of double signals Use 9V DURACELL ALKALINE batteries only l Manual programming LG 39E Multi User Factory Mode The lock maybe mounted in the factory mode It opens when Pre Setup mode pressing key 1 and it sends a silent alarm signal The advantage is that there is only 1 version storage and an easy use during mounting Keep pressed the key 0 until the double signal 4 5 seconds Now the manager code is 555555 Code length and program selection The code length and program selection are made with the 6 9 dig
2. position The lock is automatically locked check this by trying to turn the handle into OPEN position IMPORTANT Check the lock to be locked Wrong try penalty After four invalid codes the entry is blocked for about 5 minutes During this period the lock signals at 10 second intervals After this time penalty the entry of every second invalid code initiates a new 5 minutes delay period The key pressing is refused with a triple signal Change of code The user can change its code anytime always with open door Enter the code and keep pressed the last number until second double signal LED is on press the O and enter the new code double signal enter the new code once more for confirmation double signal The new code is now valid If mistakes are made while changing the code or if an interval occurs of more than 10 seconds the old code remains valid and the entire sequence has to be re entered Test the new code several times by open door LG 39E Combogard EN Revise 1 Datum 16 02 05 l Silent alarm must be programmed Time delay for opening Must be programmed Time delay override Must be programmed Power supply Safety notice LED and acoustic signals LG 39E Combogard EN Revise 1 Datum 16 02 05 If feature is active AND optional alarm box or SP box is connected If the last digit is chosen one higher 1 when entering the code the lock will open as usual double si
3. gnal but at the same time the alarm box is activated Example Combination 471147 Alarm code 471148 If feature is active After entering a valid code double signal the delay period starts the LED flashes red each 2 second interval At the end of the delay period the Open window starts the LED flashes each second and the lock beeps every 2 seconds To open the lock a valid code has to be entered during the Open window If the Open window expires without the lock being opened then the lock is secured again with the Time delay Delete current delay time press key 0 Extend current delay times enter valid code The delay period will start again The user ID 9 money carrier can open immediately At the operation with two codes the ID 9 is entered as the second code When the batteries are running low the lock will signal for about 3 seconds while being opened The batteries then have to be changed Use DURACELL ALKALINE batteries only The codes are stored in the lock also without power supply 3710 3750 and 3750K Battery compartment is in the bottom of the entry 3035 Open battery box inside door and insert new batteries If the batteries have not been changed in time and the tension does not suffice to cancel the lock s blocking feature anew 9V DURACELL ALKALINE battery can be pressed onto the contacts on the entry until the code has been entered and the entry is rotated When Time Delay is programmed use a
4. it code length is possible function 8 in a group of 2 digits The first digit is the code length and the second one is the program number Program 0 Manager mode operation with parallel code Program 1 Manager mode with delay override Program 2 Operation with two codes Program 3 Two code operation with delay override Program 4 Manager mode with alarm Program 5 Manager with alarm and with delay override Program 6 Two code operation with alarm Program 7 Two code operation alarm and delay override Programming Enter the manager code 555555 and keep pressed the function 8 last number until the double signal is repeated LED is on and enter 8 Enter the group of 2 digits code length and program number double signal and repeat the group for confirmation double signal In case of the 7 digit codes the manager code is 7x 5 Install Enable user Enter manager code and keep last digit pushed until LED function 1 stays on Press 1 double signal and enter user ID Nr f i 1 double signal Enter user code double signal and to confirm enter the code again Double signal and LED extinguished In case a new code Is not accepted 3 time signal this code is too similar to an already existing code Select new code NOTE Users who are not installed in this stage will be blocked after changing the manager code Program freeze After changing the manager code the program is fr
5. l OPERATING INSTRUCTIONS LG 39E Multi User Combogard Swingbolt Keypad 3035 3710 3750 or 3750K with reading contact Lock 39E Contact of e audit trail 3035 Generally Each pressing of a key is confirmed by a signal an acoustic signal and a LED flash A valid code is followed by a double signal an invalid code by a triple signal After an interval of more than 10 seconds the already entered part of the code is deleted and the entire sequence has to be re entered Code entering Enter the seven digit numeric code or a word with 7 characters a Operation with parallel code a double signal is followed manager mode Manager code 1234567 b Operation with dual codes Six digit numeric codes or words with six characters must be programmed For opening two valid codes must be entered Manager code 123456 and User ID 654321 Opening Combogard Enter the code and after double signal turn the entry clockwise within 3 seconds unto the hold The lock is open and the entry is rotated Swingbolt Enter the code and after double signal turn the handle within 3 seconds into the OPEN position lf the lock is not opened within 3 seconds it is automatically locked again Locking Combogard Turn the entry counter clockwise unto the hold The lock is automatically closed and the entry stands straight Check this by trying to turn the entry back again Swingbolt Turn the handle into the CLOSE
6. ozen and the program settings can only be changed after a reset to Factory Mode Reset to Factory Mode In case the manger code is lost or the setting of the lock has to be changed a reset can be executed by means of the RESET BOX PN 6066 Unplug battery from the lock or entry Push the 0 button for ca 3 minutes or leave it for 10minuts powerless and plug the RESET BOX in the BAT connection of the lock Wait until a longer signal 0 5 sec The Reset Box requires a connected 9V DURACELL ALKALINE battery The lock is in FACTORY MODE Disconnect Reset Box and plug battery back again Lock opens with 1 Safety notice Do not assign code to the users of no use for the time being Remove the codes Function 3 and user number LG 39E Combogard EN 3 Revise 1 Datum 16 02 05

Download Pdf Manuals

image

Related Search

Related Contents

Canon 148GSM C2S User's Manual  Handleiding SD500M  Philips AVENT SCF712  Gembird A4-G501 headset  チェンソー取扱説明書 - Husqvarna  User & Installation Manual  to view the persona 3 portable manual  User Manual for Fiber to Serial Media Converter Rack –VE09FSR  BARTON Floco Series F500 PD Meter IOM  Samsung MultiXpress SCX-6555N  