1. Installation Manual INTEGRATED ACCESS CONTROLLER KZ 1000 sj XaDe VERSION 1 0 enk Holding sp z 0 0 lawska 431 02 801 Warszawa tel 22 546 05 46 faks 22 546 05 01 www aat pl Integrated Access Controller Installation manual CONTENTS ue ve Lef del 3 2 Controller technical data 5 Controller wiring diagram 6 4 Controller installation eene 5 Off line management eee nare emen 8 O10 6 E _________ _ __ 12 7 Communication mode setup a ar enne 13 8 Rules for Installation nes 14 ALL rights reserved AAT Holding sp z 0 0 2 Integrated Access Controller Installation manual 1 Introduction KZ 1000 Integrated access controller The KZ 1000 controller has been designed for access control system and to be mounted on a wall without any additional enclosure This is one door control ler With additional reader it can use for two way control KZ 1000 can work in standalone or in network mode In network mode it can work on line or off line with supervisor KaDe Lite software on PC KZ 1000 include following components in one plastic cabinet control
2. twice error occurs and password setting is ineffective Warning Default administrator password 000000 must be obligatory change after first enter in Edit mode code 42 Leave default password make possible to enter in Edit mode non privilege user When you for get your own password to reset the controller can be done from within Kade context menu Controller Restore Defaults Password can also be sent from Kade Lite Setup controller simultaneously to all control lers Feature available from version V19 ALL rights reserved AAT Holding sp z 0 0 11 Integrated Access Controller Installation manual Codes table standalone mode Parameter or function name Code value after enter in Edit mode mode Enter Edit mode plus administrator password default 000000 0 Controller address 12 00 31 Anti disassemble alarm 14 00 disable 01 enable Door unlock time 21 00 99 sec Door contact input type 26 10 NO 00 NC Exit button input type 27 10 NO 00 NC gt lUsermanagement peme 39 _ Demealads Games administrator password Warning Default administrator password 000000 must be obligatory change after first enter in Edit mode code 42 Leave default password make possible to enter in Edit mode non privilege user When you for get your own password to reset the controller can be done from within Kade context menu Controller Restore Defaults
3. 0 1499 gt read the card and device sounds once exit automatically 5 3 Delete one card User can invalidate a card by delete the card number registered in the controller Only one card can be deleted in one time Edit mode gt input 33 input 4 digit initial number range from 0000 1499 gt exit automatically the card deleted is invalidated 5 4 Delete All Cards This function will invalidate all the keypad registered cards similarly initiation will also clear all cards Please be warned for applying this function Edit mode gt input 34 gt Automatic exit all off line subscribers will be cleared 6 Password management Password management refers to the management of administrator password and card holder password Administrator password is used to enter Edit mode status Card holder password is used to open the door in the password or card password door open mode 6 1 Set card holder password Card holder password can be applied in both the password and the card pass word door open mode In the Screen Door open Password mode password only is ineffective for opening door Edit mode gt input 41 gt input 6 digit password yellow light flashes gt input 6 digit password again exit automatically 6 2 Set administrator password Default administrator password 15 000000 Edit mode gt input 42 gt input 6 digit password yellow light flashes gt input 6 digit password again exit automatically If sounds
4. AT Holding sp z 0 0 5 Integrated Access Controller Installation manual ouap pegnpu eq pae uogeogpour uonoeuuco eu MOBO Apis Een yxa Dau gounge 9 UCD o 1099 anpassad 0 o e aunses lle4 e ilONUuOD SSW II I Ge ol m G G o s S J8MOg 6 0 weibeig 5 ALL rights reserved AAT Holding sp z Integrated Access Controller Installation manual Installation instruction 4 1 Remove the two keys first 4 2 Unfasten the two screws First open the lower part of Dackcover tor around icm Please note that open too wide may lead to damage to the device 4 3 Open the back cover and connectthe 4 4 Fix the backcover on the wall and device according to the wiring diagram reassemble the device according to 4 1 4 2 and 4 3 in reversed order ALL rights reserved AAT Holding sp z 0 0 Integrated Access Controller Installation manual Off line management standalone mode This function enables the admin user to manage card holders by the inte grated access controller without connecting to computer Max 1500 cards card holders can be managed in off line manager mode There is no conflict between off line cards and cards re
5. Password can also be sent from Kade Lite Setup controller simultaneously to all control lers Feature available from version V19 ALL rights reserved AAT Holding sp z o o 12 Integrated Access Controller Installation manual Communication mode setup KZ 1000 controller can operate in standalone mode or in network mode In network mode it communicate with KaDe software installed on PC There are three way for controller communication with PC direct connection using RS232 for one controller only network connection using RS485 port and transmission converter Ethernet LAN connection using TCP RS232 485 transmission converter Programming controller from KaDe software enable setup more features and on line monitoring After download database from PC controller can operate suc cessfully in off line mode a o a a a 485 232 RS485 Mode RS232 Mode Jumpers JP1 setup on the back side of controller for correct communication mode Read User Manual for KaDe software for detail information s about system programming or use Dynamic Help files display on the screen ALL rights reserved AAT Holding sp z 0 0 13 Integrated Access Controller Installation manual Rules for Installation Selection of exterior components may be based on installation environment However the selection should be in accordance to existing National and In ternational Standar
6. ad by computer The off line card possesses top authority and is not affected by such func tions as multiple card initial card remote control anti passback and access level Standalone mode is recommended only for small system a few doors Instruction for Keypad Function Sound Indication One sound means correct input continuously sound twice means error or exit Light LED Indication Blue light is for power green for valid yellow for Edit mode yellow flash for Waiting to input password and yellow light on for Edit mode status entered Keypad Edit mode Wait for 6 seconds after inputting password card password 1 Enter Edit mode Push yellow light flashes gt input administrator password yellow light on I Edit mode status entered Default administrator password is 000000 If password is not inputted or wrongly inputted within 20s sound twice and exit Edit mode status orange light off and blue light on Only one operation can be perform in one step For next operation administrator must enter Edit mode again 2 Exit Edit mode Push to exit Edit mode status Warning Default administrator password 000000 must be obligatory change after first enter in Edit mode code 42 Leave default password make possible to enter in Edit mode non privilege user When you for get your own password to reset the controller can be done from within Kade context menu Controller Restore Defaults Passw
7. between off line cards and cards read by computer The off line card possesses top authority and is not affected by such functions as multiple card initial card remote control anti passback and access level It means that those cards are valid all time Each card have unique ID from range 0000 1499 in controller memory Due to administrator can delete any card using only ID It s recommended to prepare list with name and ID before add card ItUs possible do add group of card number in one operation Cards are ready to use immediately after add ALL rights reserved AAT Holding sp z o o 10 Integrated Access Controller Installation manual 5 1 Add multiple cards A number of cards can be registered in the device with a designated first number The second card will be assigned with a number next to the number designated to the first card This continues until user exits the function automatically or manually Edit mode gt input 31 gt input 4 digit initial number range from 0000 1499 gt read the card and device sounds once then read the second card gt complete input and push to exit 5 2 Add single cards User can designate a certain number to a card Only one card can be designated in one time If the number has been designated to other card before the newly designated card will overwrite the original card the one with this number before Edit mode gt input 32 gt input 4 digit initial number range from 000
8. ds as well as matched with the controller A careful study on the instructions on exterior components selection is strongly advised Installation of the control unit including microprocessor should not be in side the high voltage box or near any large converter or high voltage current devices The components should be installed in places easy for un installation in order for convenient maintenance The controller board should be connected to earth independently Please en Sure that grounding has been provided in the installation site When install ing the box with microprocessors inside please ensure that the screw and lock has been fastened The 230V terminal power cable should be plugged in separate power supply socket the power cable should not share the socket with other devices with grounding ensured Supply power unit with backup battery is recom mended 12 VDC 1A also for electric lock Do not crossover the system cables through other devices All components should not be installed in places with excess high low tempera ture above 2 C or relative humidity 0 95 Failure to follow the instructions below may lead to the malfunction of the system property damage and even physical injury 2 1 Connection and operation on any components or the controller with power on is strictly prohibited 2 2 Connect the system according to the instructions described in this manual 2 3 The RS232 cable connected to t
9. he computer should be no more than 15 meters 2 4 The RS485 cable connected to the computer should be no more than 1200m 2 5 Please use the specified power supply 2 6 The communication mode between the controller and computer should be either RS232 or RS485 J L3 4 D 2 When RS485 mode is applied a highway can connect maximally 32 controllers with identification address differs from each other ALL rights reserved AAT Holding sp z 0 0 14 Integrated Access Controller Installation manual NOTES ALL rights reserved AAT Holding sp z 0 0 15 AAT Holding sp z 0 0 ul Putawska 431 02 801 Warszawa tel 22 546 05 46 faks 22 546 05 01 e mail aat warszawa aat pl www aat pl AIS A nau Warszawa
10. ler module card reader 125 kHz ISO UNIQUE keypad for PIN with bell button LED and Buzzer anti disassemble sensor ALL rights reserved AAT Holding sp z o o 3 Integrated Access Controller Installation manual Controller module include Supply Power connectors 12V 110 mA Communication port RS232 for direct connection with PC and KaDe Lite Communication port RS485 for connection with network Second reader port for two way control Wiegand output format Door status sensor input Exit button input Lock control relay output Alarm relay output Jumper sets for communication mode set LED located on front panel upper left Blue LED supply power indicator Green LED access granted light when door unlocked Orange LED programming mode All components are mounted in esthetics case KZ 1000 controller is designed for indoor use only When entry from outdoor is needed additional out door reader should be connected e g C 10 Controller back side connectors view Supply Power Wiegand Reader Interfejs Exit Buton Door Contact Bell ALL rights reserved AAT Holding sp z 0 0 4 Integrated Access Controller Installation manual KZ 1000 Controller Technical Data or function description Buffer capacity Electrical parameter Environment parameter Inputs Rayo Accessievelparameter ALL rights reserved A
11. net type set correct input type firmware V 01 Edit mode gt input 26 gt input two digits code 10 NO type 00 NC type I default NO exit Edit mode status 3 6 Exit button input type Depend of exit button type set correct input type firmware V 01 Edit mode input 27 input two digits code 10 NO type 00 NC type I default NO exit Edit mode status ALL rights reserved AAT Holding sp z 0 0 9 Integrated Access Controller Installation manual 4 Pass Mode Setup This function is used to define the mode of pass including three modes Card Card plus Password Password For Card Password and Password mode the Door open password and Card holder password are the same for all users 4 1 Open with card only Edit mode gt input 223 gt door will be opened once the card is valid 4 2 Open with card plus password Edit mode gt input 234 gt door will be opened once the card is valid and card holder password is correctly inputted 4 3 Door open password disable Edit mode gt input 243 gt input door open password can not open the door 4 4 Door open password enable Edit mode gt input 254 gt input door open password can open the door 5 Off line user management This function enables the user to manage card holders by the integrated access controller without connecting to computer Max 1500 cards card holders can be managed in Off line manage mode There is no conflict
12. ord can also be sent from Kade Lite Setup controller simultaneously to all control lers Feature available from version V19 ALL rights reserved AAT Holding sp z 0 0 8 Integrated Access Controller Installation manual 3 Basic setup Basic setup includes system initiation address setup anti disassemble alarm setup door open setup 3 1 System Initiation System initiation will clear all original setup of the controller including pass mode setup basic setup all keypad added card password etc however administrator setup will not be changed Edit mode gt input 11 gt wait for 3 second blue light on I exit Edit mode status 3 2 Setup address Address is applied to differentiate the controller from any other devices on the network An address within a single 485 network should be unique Edit mode input 12 input address e g 29 range 00 31 I exit Edit mode address is set as 29 default 00 3 3 Anti disassemble alarm setup Anti disassemble alarm is applied to protect controller from being disassem bled or damaged Edit mode input 14 gt input Edit mode code OO cancel alarm 01 activate alarm I exit Edit mode status 3 4 Door open Setup After use valid legal card door strike will be unlocked for time duration set below Edit mode gt input 21 gt input door open duration range 00 99 second I default 3 sec exit Edit mode status 3 5 Door contact input type Depend of door mag