1. 2 4 Electrical Installation requirements The Xilver RainDrop Fixture is designed to be used in conjunction with Xilver X 900 Intelligent Controllers Note Only use Xilver approved Intelligent Controllers and cabling The RainDrop Fixture is fitted with a cable with an 8 pin IP65 rated male connector This connector suits Xilver supplied cabling Plug the male connector in a female note the orientation pin inside the connector and screw the two locking rings into eachother Note When looking into the female connector around the center insert a rubber O ring should be present When using Xilver products outdoors always verify that this ring is clean and undamaged For pin layout see Appendix 3 Wiring Chart The Xilver X series Power and Data wiring system is inherently different from DMX RS232 or Ethernet A single connector is used for power input and data in and output This means that in order to connect multiple fixtures to a single output on a Xilver X 900 Intelligent Controller Y adapters must be used Note if connectors are left loose e g not connected to a fixture all of the fixtures connected to that output will not be operational Use a Xilver approved terminator on that position The maximum operational cable lenght between a X 900 Intelligent Controller and a RainDrop Fixture is specified at 100 metres A maximum of 40 RainDrop Fixtures can be connected to a sin
2. Electrical and Electronic Equipment 2002 95 EC directives The selection of hazardous substances in all components and parts has been reviewed with care in order to comply or exceed the RoHS directive If this product when purchased and used in the EU has reached the end of its usefull life it may be returned to the original dealer at no cost or to Xilver International with a proof of ownership Chapter 1 Description 1 1 Application The Xilver RainDrop LED Lighting Fixture is designed as a highly advanced lighting instrument It is designed to be a robust easy to install reliable lighting fixture to be used in temporary or permanent installations indoor or outdoor 1 2 Features The RainDrop RGB LED Lighting Fixture incorporates the following technologies and features Lumiled Rebel LED sources Environmental protection to IP65 Powder coated die cast housing Cable management behind the fixture allowing surface mounting M8 attachment point for standard clamps Polycarbonate dome UV stable Automatic Temperature correction Power and Data supply via Xilver X 900 Intelligent Controller Setup with the Xilver X Navigator pc application thru the Xilver X 900 Intelligent Controller 1 3 Products For operation of the RainDrop RGB LED Lighting Fixture the following products are required One or more RainDrop RGB LED Lighting Fixtures Proprietary Xilver X series c
3. Top Isometric view N DOO FP WN 1 Dome Vents Connector Mounting hole 2x Heatsink Mounting Hole internally threaded M8 NI OO oa RR o nrp Cable slot 2 3 Mechanical Installation requirements The RainDrop Fixture is designed to be mounted in any orientation The RainDrop Fixture can be used outdoors rated to IP65 specification Please note that these specifications do not allow for submersion It can be wallmounted via two attachment points in the outer ring It can be attached to any other object via the rear mounted M8 threaded hole When attaching a RainDrop Fixture to an object ensure that this object is suited to the weight heat exposure and mounting method chosen for this RainDrop Fixture Warning When in operation the RainDrop Fixture may reach high temperatures Do not touch the fixture by hand during operation Allow sufficient time after removing electrical power for cooling before handling any RainDrop Fixture Warning This fixture is convection cooled Allow for sufficient airflow to this fixture Failure to do so may shorten the operational life of this fixture and may void warranty During mounting of the RainDrop Fixture use caution to prevent breaks and damage to the power input cable of the RainDrop Fixture In the outer ring 2 gaps are present which are specifically designed to guide the cable from this fixture
4. User manual Xilver RainDrop RGB Table of Contents I Declaration of Conformity Il Important Safety Instructions Ill Disclaimer IV About this Manual V Customer Service and Warranty VI Recycling and hazardous substances Chapter 1 Description 1 1 Application 1 2 Features 1 3 Products 1 4 Xilver Power and Data structure Chapter 2 Installation 2 1 Included Items 2 2 Layout 2 3 Mechanical Installation requirements 2 4 Electrical Installation requirements Appendix 1 Maintenance Appendix 2 Specifications Appendix 3 Wiring Chart I Declaration of Conformity Manufacturer s name Xilver International B V Adress Proostwetering 50 3453 AH Utrecht The Netherlands Declares that the product Name RainDrop RGB LED Lighting Fixture Conforms to the following EEC Directives 89 336 EEC Electromechanical Contamination Directive 2006 95 EEC Low Voltage Directive IEC 60950 1 2005 mod Safety of Information Technology Equipment including Electrical Business Equipment EN55022 1998 A1 2000 A2 2003 Information technology equipment Radio disturbance characteristics EN 55024 1998 A1 2000 A2 2003 Information technology equipment Immunity characteristics Utrecht June 11th 2009 Xilver International B V ll Important Safety Instructions It is extremely important to read ALL safety information and instructions provided in this manual and any accompanying documentation before installing and o
5. abling A Xilver X 900 Intelligent Controller connected to either DMX or Ethernet The PC based Xilver X Navigator configuration application 1 4 Xilver Power and Data structure Xilver products are designed around a proprietary Power and Data supply structure This structure allows an optimal use of power data and distance from a Xilver X 900 Intelligent Controller whilst safeguarding the environmental protection The power connector on every fixture is an 8 pin connector with power and data in and out To connect multiple fixtures to a single output from a Xilver X 900 Intelligent Controller Xilver Y adapters must be used When an connector is left unterminated all fixtures on that output will not be operational In this event a propriatary Xilver X series Terminator must be used The Xilver Power and Data structure is based around a 48V DC power source capable of supplying a maximum of 5 amperes The electronics and cable used guarantee a maximum distance of 100 metres between the X 900 Intelligent Controller and the last fixture on the line The data signal used is not compatible to DMX Chapter 2 Installation 2 1 Included Items In the box containing this product the following items should be present 1 Xilver RainDrop RGB LED Lighting Fixture 1 Manual this manual Caution When unpacking handle the fixture with care The dome is sensitive to scratches 2 2 Layout
6. gle output with a total of 160 RainDrop Controllers Warning Do not plug or unplug connectors while the Xilver X 900 Intelligent Controller is powered 2 5 Software setup For adressing fixture settings test procedures and all other features please refer to the Xilver Navigator PC Application manual The RainDrop Fixture itself is not fitted with a human user interface or display features 2 6 DMX Control parameters DMX Parameter Value Intensity Value Intensity Ch1 Red 0 0 255 100 Ch2 Green 0 0 255 100 Ch3 Blue 0 0 255 100 Appendix 1 Maintenance A1 1 Housing Clean the exterior housing with a slightly moist lintfree cloth Do not use abrasive cleaning agents A1 2 Light Source This product uses High Power LED s During normal use within the conditions as specified replacement of the light sources may be required after 50 000 hours of use Replacement of the lightsources must be performed by qualified personnel only For color calibration any Raindrop fixture must be returned to your local Xilver dealer A1 3 Servicing Do not open this unit Doing so will void warranty and might present a risk Servicing must be performed by qualified personnel only Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug being damaged liquid has been spilled or objects have fallen into the ap
7. paratus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped Always contact your local Xilver dealer for instructions to obtain service Appendix 2 Specifications A2 1 Optical Beam Angle 360 x 170 deg Light Source 3x LumiLed Rebel Average Source Life 50 000 hours A2 2 Mechanical Size physical WxHxD 80 x 58 x 80 mm Weight physical 0 175 Kg Ingress protection rating IP65 A2 3 Electrical Input voltage 48V DC Power consumption 6 Watt max A2 4 Environmental specifications Operational Temperature 0 45 deg C Storage Temperature 10 60 deg C Humidity 10 90 non condensing Operational Altitude 2400m max Storage Altitude 6000m max Appendix 3 Wiring Chart The Xilver Power and Data structure uses a proprietary IP65 rated 8 pin locking connector connector specified at max 5 amperes Pin Wire Color Signal 0 Grey 0 Volt 1 White 0 Volt 2 Blue Data In 3 Brown Data In 4 Red Data In 5 Pink Data In 6 Green 48 Volt DC 7 Yellow 48 Volt DC International Sales Office Xilver International B V Phone 31 0 30 2482200 Fax 31 0 30 2482201 Email info xilver nl Web www xilver nl Manual rev 1 0 June 2009
8. perating the products described herein Heed all cautions and warnings during installation and use of this product Keep this instruction manual for future reference This unit does not contain any user serviceable parts Do not open this unit Doing so will void warranty and might present a risk Servicing must be performed by qualified personnel only Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug being damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped Do not install near any heat sources such as radiators heat registers stoves or other apparatus including amplifiers that produce heat This unit is not designed for residential use Do not block any ventilation openings Install in accordance with the manufacturer s instructions Allow for sufficient airflow to this unit Do not connect or disconnect the power connector under load Protect the power lead from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus When damaged replace the power lead Unplug this apparatus during lightning storms or when unused for long periods of time Do not stare into the beam of this unit the intense light output may cause injury to the eye Do not leave this unit in strobe mode for indefini
9. te time This may cause epilleptic response When in operation this device may reach high temperatures Do not touch the fixture by hand during operation Allow for sufficient time for cooling before handling this device lll Disclaimer All rights reserved Although the information in this manual has been compiled with care individual items may vary in size ratings and functionality from what is included in this manual Xilver disclaims any liability for damage losses or other consequences suffered or incurred in connection with the use of the measurements data or information contained in this manual Xilver may change this product without prior notice IV About this Manual This Manual provides basic information explaining the functionality installation operation and maintenance of the Xilver RainDrop RGB LED fixture This manual serves as a first reference for the use of this product V Customer Service and Warranty This product is supplied with a limited warranty for 12 months following purchase To obtain warranty service please contact your local Xilver dealer Please do not send equipment to Xilver International without authorisation If asked to do so please add a copy of the original invoice together with the faulty device in a secure shipping container VI Recycling and hazardous substances This product complies to the EU RoHS Reduction of Hazardous Substances 2002 96 EC and WEEE Waste