GT01-RS4-M Serial Multi-Drop Connection Unit USER'S MANUAL

image

Contents

1. Host PC Ad ESAIK A id ES e E For GOT Controller Setting L Controller Setting CH 1 MELSEC QnU 017 gh Network Duplex Setting Manufacturer Mitsubishi h Q Redundant Controller Type MELSEC QnU G17nD M NC DR 1 F Standard I F RS422 232 Driver Multidrop Slave Detail Setting Property Value Transmission Speed BPS 115200 Retry Times 0 Timeout Time Sec 3 GOT Address 0 0 Delay Timefms For instructions on how to download the project data refer to the GT Designer2 Version2 Basic Operation Data Transfer Manual or GT Designer3 Version0 Screen Design Manual 5 Connect the cable For details of the cable connection refer to the GOT1000 Series Connection Manual 3 Specifications 3 1 General Specifications Item Operating ambient temperature Storage ambient temperature Operating Storage ambient humidity Vibration resistance Shock resistance Operating atmosphere Operating altitude Cooling method External dimensions DxWxH Weight Installation method Exterior color Case Standard Specifications 0 to 55 C 20 to 60 C 10 to 90 RH non condensing The wet bulb temperature is 39 C or less Installed with DIN 1Otos7Hz j o O O2omin directions 10 to 57Hz Po 0 075mm Total 80 minutes for each Conforms to JIS C60068 2 27 147 m s2 11 ms Sine half wave pulse 3 times each in the X Y and Z directions Swe
2. 1 3 Compatible GOT The followings are the GOTs compatible with the GOT multi drop connection For the confirmation method of the hardware version refer to the User s Manual of each GOT GOT Hardware version GT16 GT15 GT1155 QTBD GT1155 QSBD GT1150 QLBD GT1055 QSBD GT1050 QBBD GT1045 QSBD GT1040 QBBD GT1030 LBD LWD GT1030 LBDW LWDW GT1020 LBD LWD GT1020 LBDW LWDW Soon to be supported Version C or later Version F or later Version C or later Version A or later Version B or later Version E or later 1 4 Compatible drawing software version GT Designer2 Version2 Ver 2 93X or later GT Designer3 Version1 Ver 1 01B or later 2 Outline Procedure The outline procedure is shown below 1 Install the OS e Install the communication driver of the PLC connected to the multi drop connection module e Install the communication driver multi drop Slave to the GOT For details of the installation method refer to the GT Designer2 Version2 Basic Operation Data Transfer Manual or GT Designer3 Version For GT Designer2 For multi drop connection module Communicate with GT01 RS4 M Communication configuration Computer gt GTO1 RS4 M 0S Computer gt GTO1 RS4 M Comm Param Communication configuration M Standard monitor OS Standard monitor OS 01 11 00 s H Communication driver O QnA CPU 01 07 00 O MELSEC A 01 07 00 MELSEC FX 01 07 00 For GOT Communicate with
3. 232 set to RS 422 by default For connecting to a personal computer for changing the communication driver D sub 9 pin female Protect unused D sub connector USB port and switches Terminal block 5 pin with a protective cover M3 Tightening torque 0 5 to 0 6N m 24VDC power supply connector insertion point A dedicated cable is included Do not operate Set to right by default When set to left the module does not operate normally 5 Installation 6 2 2 For 2 pair wiring 5 1 Installed with DIN Rail Make sure to ground a twisted pair cable by applying Class D Grounding 100 or less Install ine multi drop connection moane with its hook 1 place using the DIN rail Multi drop GOT side GOT side GOT side e Applicable DIN rail DIN46277 width 35mm connection module Install the DIN rail with screws at intervals of 150mm a Signal Signal Signal Cable for GT11 Signal name name name name 5 2 Directly Installed to Panel SDA SDA panu SDA SDA es Install the multi drop connection module to the panel using 4 5mm holes 2 places a SDB SDB SDB spp i Terminating Terminating i resistor 5 3 Caution for compliance with EMC Directive resistor RDA y RDA y y RDA festu 3300 Programmable logic controllers are open type devices that must be installed and used within conductive control boxes Please use the Multi Drop Connection Unit while 330Q ar
4. 232 connection D sub 9 pin male Dielectric withstand voltage 500VAC for 1 minute across power supply terminals and earth 5 Connector selection switch for PLC communication Switch for selecting RS 422 or RS 232 set to RS 422 by default Insulation resistance 10MQ or larger by insulation resistance tester across power supply terminals and earth 6 USB port For connecting to a personal computer for changing the communication driver Grounding Class D grounding 100 or less To be connected to the panel when grounding is not possible 7 Connector for PLC communication for RS 422 connection D sub 9 pin female 9 Terminal block for the serial multi drop communication Terminal block 5 pin with a protective cover M3 Tightening torque 0 5 to 0 6N m 10 Power supply connector 24VDC power supply connector insertion point A dedicated cable is included 11 Slider for installing the DIN rail 12 Mode selection switch Slide switch Do not operate Set to right by default When set to left the module does not operate normally 5 Installation 6 2 2 For 2 pair wiring 5 1 Installed with DIN Rail Make sure to ground a twisted pair cable by applying Class D Grounding 100 or less Install ine multi drop ponnerugn module with its hook 1 place using the DIN rail BiG Multi drop GOT side GOT side GOT side e Applicable DIN rail DIN46277 width 35mm connection module Install the DIN rail with screws at intervals of 150mm Signal Signal
5. GOT Project Download gt GOT Project Upload gt Computer C Standard monitor OS s H Communication driver O 4 QnA0 CPU QJ71C24 04 03 00 4 710C24 MELDAS C6 04 03 00 Dy 4 71024 UC24 04 03 00 O MELSEC Fx 04 03 00 O CC Link G4 04 03 00 O MELSERVOJ3 J25 M 04 03 00 Multidrop Slave 04 03 00 O FREQROL 500 700 04 03 00 O OMRON SYSMAC 04 03 00 O OMRON THERMAC INPANEL NEO 04 03 00 O KEYENCE Kv 700 1000 04 03 00 O KOYO KOSTAC DL 04 03 00 O ITEKT TOYOPUC PC 04 03 00 O SHARP Jw 04 03 00 MI SHINKO TECHNOS CONTROLLER 04 03 001 GOT Type GT11 0 320x240 X Transfer size Install For GT Designer3 For multi drop connection module Communicate with GT01 RS4 M GSB Gt01 As4M write 0s aE GT01 RS4 M write Comm Param Standard monitor OS 01 13 01 FJ Gn4 L O CPU 01 07 04 O MELSEC 01 07 01 MELSEC FX 01 07 03 S Communication driver Write Mode 150 kbyte Install For GOT Communicate with GOT E GOT write Resource Upload gt Computer OS Install gt GOT Boot OS Instal gt GOT Verily Special Data Download gt GOT Drive information User area size kbyte Empty area size i kbyte Memory meter Hused W Empty Boot Memory information User area size Empty area size p T kbyte Get Latest Be cornea GY LY Gor verity Screen Design Manual Drive information St
6. The static electricity can cause the unit to fail or malfunction MOUNTING PRECAUTIONS CAUTION e Use the Multi Drop Connection Unit in the environment that satisfies the general specifications described in this manual Not doing so can cause an electric shock fire malfunction or product damage or deterioration PRECAUTIONS WIRING PRECAUTIONS lt SDANGER e Be sure to shut off all phases of the external power supply used by the system before wiring Failure to do so may result in an electric shock product damage or malfunctions Please make sure to ground FG terminal of the Multi Drop Connection Unit power supply section by applying 100 or less which is used exclusively for the GOT Not doing so may cause an electric shock or malfunction Correctly wire the Multi Drop Connection Unit power supply section after confirming the rated voltage and terminal arrangement of the product Not doing so can cause a fire or failure Tighten the terminal screws of the Multi Drop Connection Unit power supply section in the specified torque range Undertightening can cause a short circuit or malfunction Overtightening can cause a short circuit or malfunction due to the damage of the screws or the Multi Drop Connection Unit Exercise care to avoid foreign matter such as chips and wire offcuts entering the Multi Drop Connection Unit Not doing so can cause a fire failure or malfunction WIRING PRECAUTIONS CAUTION e Plug the communication ca
7. personal injury or physical damage Depending on circumstances procedures indicated by CAUTION may also be linked to serious results In any case it is important to follow the directions for usage DESIGN PRECAUTIONS DANGER e Some failures of the Multi Drop Connection Unit or cable may keep the outputs on or off An external monitoring circuit should be provided to check for output signals which may lead to a serious accident Not doing so can cause an accident due to false output or malfunction If a communication fault including cable disconnection occurs during monitoring on the GOT communication between the GOT and PLC CPU is suspended and the GOT becomes inoperative A system where the GOT is used should be configured to perform any significant operation to the system by using the switches of a device other than the GOT on the assumption that a GOT communication fault will occur Not doing so can cause an accident due to false output or malfunction Do not use the Multi Drop Connection Unit as the warning device that may Cause a serious accident An independent and redundant hardware or mechanical interlock is required to configure the device that displays and outputs serious warning Failure to observe this instruction may result in an accident due to incorrect output or malfunction DESIGN PRECAUTIONS NCAUTION e Do not bundle the control and communication cables with main circuit power or other wiring Run the
8. switch Check the following items Blinking in red e Check that the Mode selection switch is set to the right o e The OS may be faulty Install the standard OS and communication driver from GT Designer2 or GT Designer3 to the multi drop 6 2 Wiring and Terminating Resistor Setting module again 6 2 1 For 1 pair wiring Make sure to ground a twisted pair cable by applying Class D Grounding 100 or less Multi drop PLC connectionimodul GOT side GOT side GOT side a Signal Cable for GT11 Signal name name SDA SDB f i RDA CEERD ii met RDB E a r 2 al Terminating SG Terminating resistor tT resistor 1102 Class D Class D Class D Sas Grounding Grounding Grounding RSB CSA This manual confers no industrial property rights or any rights of any other kind CSB nor does it confer any patent licenses Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may The terminating resistor 110Q is built in the multi drop connection module and GOT GT10 GT11 occur as a result of using the contents noted in this manual Make sure to set the terminating resistor to both ends of the line For GT15 or GT 16 external wiring is required Set the terminating resistor of the GOT that is not at the end of the line to OPEN Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi opportunity loss or lost profits caused by faults in th
9. to the GT01 RS4 M GT01 RS4 M can set 1 Communication parameter setting of driver for connected GOT 2 Communication parameter setting of driver for connected Controller Please select the Controller connected with the GTO1 RS4 M and set details of Communication parameter For Connected GOT Zi Details For Controller MELSEC FX Details Close For GT Designer3 For multi drop connection module Communicate with GT01 RS4 M AFE GT01 As4 m writes SPB GTO1 AS4 M Write Comm Param x For Connected GOT For Controller MELSEC FX Paints of caution Communication parameter setting will be written into GT01 RS4 M 1 Communication parameter setting of driver for GOT connection and 2 Communication parameter setting of driver for controller connection can be set for GTO1 RS4 M Select a controller to be connected with GT01 RS4 M and set the details Communication Configuration 4 Download the project data For GOT Ek f System Environment System Settings Project Title Standard I F Settings Auxiliary Setting CH No VF Driver System Information Screen Switching Standard 1 F 1 1 Multidrop Slave Security Standard 1 F 2 g Key Window Dialog Window Standard F 3 Host PC GOT Setup OK Cancel Apply Language Switching Clock Setting Startup Logo G Handy Got MV Use Communication Settings Detail Setting X X
10. 1 RS4 M of GT Designer2 or GT Designer3 e For the GOT set the communication interface in the Communication Settings of GT Designer2 or GT Designer3 For details refer to the GT Designer2 Version2 Basic Operation Data Transfer Manual or GT Designer3 Version Screen Design Manual Screen Design Manual For GT Designer2 For multi drop connection module Communicate with GT01 RS4 M Communication configuration Computer gt GTO1 AS4 M 0S Computer gt GTO1 AS4 M Comm Param Download setting of Communication parameter to the GTO1 AS4 M GTO1 RS4 M can set 1 Communication parameter setting of driver for connected GOT 2 Communication parameter setting of driver for connected Controller Please select the Controller connected with the GT01 RS4 M and set details of Communication parameter For Connected GOT ullictopiont Details MELSEC FX i Details For Controller For GT Designer3 For multi drop connection module Communicate with GT01 RS4 M 3 AFB GT0 AS4M writes 29E GT01 RS4 M Wrte Comm Param vi Desis For Connected GOT ul drop ost For Controller MELSEC FX Paints of caution Communication parameter setting will be written into GT01 RS4 M 1 Communication parameter setting of driver for GOT connection and 2 Communication parameter setting of driver for controller connection can be set for GTO1 AS4 M Select a contro
11. Cable for GT11 Signal name name name name 5 2 Directly Installed to Panel SDA ry Yr SDA h HHH SDA fe Install the multi drop connection module to the panel using 4 5mm holes 2 places ne SDB SDB SDB f Terminating Terminating i resistor 5 3 Caution for compliance with EMC Directive resistor RDA TT Vi RDA RDA paia 3500 Programmable logic controllers are open type devices that must be installed and used within conductive control boxes Please use the Multi Drop Connection Unit while 3309 jt RDB RDB RDB J nr P installed in conductive shielded control boxes Please secure the control box lid to the control box for conduction Installation within a control box greatly affects the safety of Terminating Terminating Aue es ermina ing SG SG SG SG resistor the system and aids in shielding noise from the Multi Drop Connection Unit t resistor a ee ee eee ae 3300 E 3309 F RSA a RSA z RSA 6 Wiring Class D Class D a Class D ans 6 1 Power Supply Wiring Grounding Grounding Grounding Connect the power supply cable with connectors included and the 24VDC terminal of the external power supply CSA CSA CSA CSB CSB CSB Aff 6 2 Wiring and Terminating Resistor Setting 6 2 1 Make sure to ground a For 1 pair wiring twisted pair cable by applying Class D Grounding 1002 or less Multi drop PLC
12. F4 USB Transmissi RS 422 1ch RS 232 1ch RS 485 ich USB device ich 115 200 57 600 38 400 19 200 9 600 4 800 bps Full Speed 12Mbps Photocoupler insulation Mini B Receptacle D sub 9 pin male oe block attach detach 500m max maximum overall Number of GOTs that can be connected Half duplex and full duplex Communication method Full duplex Can be selected depending on the wiring Application For PLC connection Cannot be used simultaneously with I F2 For PLC connection Cannot be used simultaneously For multi drop connection with I F1 PC communication OS installation 3 3 Power Supply Specifications Item Input power supply voltage Specifications 24VDC 10 15 Fuse built in not exchangeable 1A Power consumption Inrush current Dielectric withstand voltage Insulation resistance Grounding 3 36W or less 140mA 24VDC 14A or less 24VDC 2ms 500VAC for 1 minute across power supply terminals and earth 10MQ or larger by insulation resistance tester across power supply terminals and earth Class D grounding 1009 or less To be connected to the panel when grounding is not possible 3 4 LED Light Specifications LED Name POWER SD RD ERROR For details of corrective actions refer to Chapter 7 Troubleshooting E Pe Not lit m a Not lit E asa Not lit Not lit Lit in red Blinking in red 4 Exte
13. Item GT01 RS4 M main unit Power supply cable with connectors GT01 RS4 M Multi Drop Connection Module User s Manual this manual 1 System Configuration 1 1 System Configuration GOT multi drop connection is a communication method for 1 N communication by connecting multiple GOTs to one PLC using the GT01 RS4 M serial multi drop connection module e GT Designer2 e GT Designer3 Communication driver e Communication interface e Communication driver e Communication interface Serial multi drop connection module Varies according to the connection type RS 485 cable 1 2 Compatible PLC For PLCs compatible with the GOT multi drop connection refer to the GOT1000 Series Connection Manual ar Describes specifications and settings of the object functions used in GT Designer2 SH 080866ENG Describes methods of the GT Designer3 installation operation basic operation for drawing and transmitting data to GOT1000 series Number of Items 1 3 Compatible GOT The followings are the GOTs compatible with the GOT multi drop connection For the confirmation method of the hardware version refer to the User s Manual of each GOT GOT Hardware version GT16 GT15 GT1155 QTBD GT1155 QSBD GT1150 QLBD GT1055 QSBD GT1050 QBBD GT1045 QSBD GT1040 QBBD GT1030 LBD LWD GT1030 LBDW LWDW GT1020 LBD LWD GT1020 LBDW LWDW Soon to be supported Version C or later Version F or l
14. JY997D35801C a MITSUBISHI GT01 RS4 M Serial Multi Drop Connection Unit USER S MANUAL Manual Number JY997D35801C This manual describes the specifications of the product Before use read this manual and manuals of relevant products fully to acquire proficiency in handling and operating the product Make sure to learn all the product information safety information and precautions And store this manual in a safe place so that you can take it out and read it whenever necessary Always forward it to the end user Registration The company name and the product name to be described in this manual are the registered trademarks or trademarks of each company Effective Oct 2009 Specifications are subject to change without notice 2009 Mitsubishi Electric Corporation Changes for the Better GRAPHIC OPERATION TERMINAL GOTOO Safety Precaution Read these precautions before using Before using this product please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly The precautions given in this manual are concerned with this product In this manual the safety precautions are ranked as DANGER and CAUTION Indicates that incorrect handling may cause hazardous DANGER conditions resulting in death or severe injury Indicates that incorrect handling may cause hazardous NCAUTION conditions resulting in medium or slight
15. RDB RDB RDB J o installed in conductive shielded control boxes Please secure the control box lid to the control box for conduction Installation within a control box greatly affects the safety of Terminating Terminating the system and aids in shielding noise from the Multi Drop Connection Unit ee SG SG SG resistor L 5 4 SSS SS 330Q 330Q RSA RSA z RSA 6 Wiring Class D Rp Class D RER Class D 6 1 Power Supply Wiring Grounding Grounding Grounding Connect the power supply cable with connectors included and the 24VDC terminal of the external power supply CSA CSA CSA CSB CSB CSB The terminating resistor 330Q is built in the multi drop connection module and GOT GT10 GT 11 Make sure to set the terminating resistor to both ends of the line For GT15 or GT16 external wiring is required Set the terminating resistor of the GOT that is not at the end of the line to OPEN 7 Troubleshooting In the case where ERROR LED is lit or blinking check the following items Status of ERROR LED Description Aff T Check the following items e Check if the power supply status is normal or not e Check the wiring of the connection cable pee e Install the correct communication driver rey e Check if the communication interface to which the cable is connected is correct or not e Check the setting of the RS 422 RS 232 selector
16. above cables separately from such wiring and keep them a minimum of 100mm 3 94in apart Not doing so noise can cause a malfunction MOUNTING lt SDANGER e Be sure to shut off all phases of the external power supply used by the system before mounting or removing the Multi Drop Connection Unit to from the panel Not doing so can cause the unit to fail or malfunction e When installing the battery wear an earth band etc to avoid the static electricity The static electricity can cause the unit to fail or malfunction MOUNTING PRECAUTIONS CAUTION e Use the Multi Drop Connection Unit in the environment that satisfies the general specifications described in this manual Not doing so can cause an electric shock fire malfunction or product damage or deterioration PRECAUTIONS WIRING PRECAUTIONS lt SDANGER e Be sure to shut off all phases of the external power supply used by the system before wiring Failure to do so may result in an electric shock product damage or malfunctions Please make sure to ground FG terminal of the Multi Drop Connection Unit power supply section by applying 100 or less which is used exclusively for the GOT Not doing so may cause an electric shock or malfunction Correctly wire the Multi Drop Connection Unit power supply section after confirming the rated voltage and terminal arrangement of the product Not doing so can cause a fire or failure Tighten the terminal screws of the Multi Drop Connection U
17. ad gt GOT Project Upload gt Computer Resource Upload gt Computer Drive information Communication configuration OS Install gt GOT Boot OS Install GOT Verify Special Data Download gt GOT 7 Standard monitor 0S F Drive information s H Communication driver O QnQ CPU QJ71C24 04 03 00 C 4J710C24 MELDAS CE 04 03 00 0 4J71024 U024 04 03 00 O MELSEC FX 04 03 00 O CC Link G4 04 03 00 Memory meter O MELSERVOJ3 J25 M 04 03 00 E Used E Empty Multidrop Slave 04 03 00 O FREGROL 500 700 04 03 00 OMRON SYSMAC 04 03 00 OMRON THERMACZINPANEL NEO 04 03 00 O KEYENCE K 700 1000 04 03 00 O KOYO KOSTAC DL 04 03 00 DIJTEKT TOYOPUC PC 04 03 00 O SHARF Jw 04 03 00 MI SHINKO TECHNOS CONTROLLER 04 03 001 User area size Empty area size Boot Memory information User area size Empty area size GOT Type GT11 0 320x240 Transfer size 150 kbyte Install Get Latest For GOT Communicate with GOT 9D cor wie Te GoT Reaal GY LY cot veiy Write Data Project Data OS Boot OS Write Mode Select write data Write Check Acquire GOT information Write Data Size Project Data 0 Kbyte B Communication driver A Os 150 Kbyte 4 On4 L 0 CPU QJ71C24 LJ71C24 05 02 53 4J710024 MELDAS C6 05 02 53 4J71024 UC24 05 02 53 MELSEC FX 05 02 53 CC Link G4 05 02 53 MELSERVOJ3 J2S M 05 02 53 Multidro
18. an cause an accident due to false output or malfunction If a communication fault including cable disconnection occurs during monitoring on the GOT communication between the GOT and PLC CPU is suspended and the GOT becomes inoperative A system where the GOT is used should be configured to perform any significant operation to the system by using the switches of a device other than the GOT on the assumption that a GOT communication fault will occur Not doing so can cause an accident due to false output or malfunction Do not use the Multi Drop Connection Unit as the warning device that may Cause a serious accident An independent and redundant hardware or mechanical interlock is required to configure the device that displays and outputs serious warning Failure to observe this instruction may result in an accident due to incorrect output or malfunction DESIGN PRECAUTIONS Z CAUTION e Do not bundle the control and communication cables with main circuit power or other wiring Run the above cables separately from such wiring and keep them a minimum of 100mm 3 94in apart Not doing so noise can cause a malfunction MOUNTING lt SDANGER e Be sure to shut off all phases of the external power supply used by the system before mounting or removing the Multi Drop Connection Unit to from the panel Not doing so can cause the unit to fail or malfunction e When installing the battery wear an earth band etc to avoid the static electricity
19. andard monitor OS Write Data Project Data OS Boot OS Select write data v GT11 O 320 240 C Built in Flash Memory Communication driver 4J710C24 MELDAS C6 05 02 53 4J71024 UC24 05 02 53 MELSEC FX 05 02 53 CC Link G4 05 02 53 MELSERVOJ3 J25 M 05 02 53 Multidrop Slave 05 02 50 FREQROL 500 700 05 02 53 OMRON SYSMAC 05 02 53 OMRON THERMAC INPANEL NEO 05 02 53 KEYENCE KY 700 1000 05 02 53 KOYO KOSTAC DL 05 02 53 JTEKT TOYOPUC PC 05 02 53 SHARP Jw 05 02 53 OOOOOOOs8O000000 A Qn4 L 0 CPU QJ71C24 LJ71C24 05 02 53 A m cumra tecunine easitoniico memen Y i gt C Write after deleting all contents in the project folder ecial Vata Write Check Acquire GOT information Write Data Size Project Data 0 Kbyte os 150 Kbyte Total 150 Kbyte Write Drive Information aT B Data Area Kbyte E Free Space Kbyte GOT Write Communication Configuration 2 Make sure that the OS is installed Communication Configuration Info Reception Close Check GT Designer2 or GT Designer3 drive information to know if the OS is properly installed in the GOT For details refer to the GT Designer2 Version2 Basic Operation Data Transfer Manual or GT Designer3 Version 3 Set the communication interface e For the multi drop connection module set the communication interface in the communication setting with GT0
20. ater Version C or later Version A or later Version B or later Version E or later 1 4 Compatible drawing software version GT Designer2 Version2 Ver 2 93X or later GT Designer3 Version1 Ver 1 01B or later 2 Outline Procedure The outline procedure is shown below 1 Install the OS e Install the communication driver of the PLC connected to the multi drop connection module e Install the communication driver multi drop Slave to the GOT For details of the installation method refer to the GT Designer2 Version2 Basic Operation Data Transfer Manual or GT Designer3 VersionU Screen Design Manual For GT Designer2 For multi drop connection module Communicate with GT01 RS4 M Communication configuration Computer gt GT01 RS4 M OS Computer gt GTO1 RS4 M Comm Param a Standard monitor OS Standard monitor OS 01 11 00 s H Communication driver O Gn4 0 CPU 01 07 00 O MELSEC A 01 07 00 MELSEC FX 01 07 00 gt Install Close For GT Designer3 For multi drop connection module Communicate with GT01 RS4 M GB GT0RS4M wite OS ERB GT01 AS4M Wrte Comm Param a Standard monitor 0S V Standard monitor OS 01 13 01 V Communication driver C Gn4 L O CPU 01 07 04 C MELSEC A 01 07 01 M MELSEC FX 01 07 03 Communication Configuration 2 Make sure that the OS is installed For GOT Communicate with GOT Project Downlo
21. ble into the connector of the connected unit and tighten the mounting and terminal screws in the specified torque range Undertightening can cause a short circuit or malfunction Overtightening can cause a short circuit or malfunction due to the damage of the screws or unit STARTUP MAINTENANCE PRECAUTIONS CAUTION e Do not disassemble or modify the Multi Drop Connection Unit Doing so can cause a failure malfunction injury or fire e Do not touch the conductive and electronic parts of the Multi Drop Connection Unit directly Doing so can cause a Multi Drop Connection Unit malfunction or failure e The cables connected to the Multi Drop Connection Unit must be run in ducts or clamped Not doing so can cause the Multi Drop Connection Unit or cable to be damaged due to the dangling motion or accidental pulling of the cables or can cause a malfunction due to a cable connection fault e When unplugging the cable connected to the unit do not hold and pull the cable portion Doing so can cause the unit or cable to be damaged or can cause a malfunction due to a cable connection fault e Do not drop or apply any impact to the battery If any impact has been applied discard the battery and never use it The battery may be damaged by the drop or impact e Before touching the unit always touch grounded metal etc to discharge static electricity from human body etc Not doing so can cause the Multi Drop Connection Unit to fail malfuncti
22. connection module GOT side GOT side GOT side i Signal Cable for GT11 Signal name name SDA y y SDA SDB SDB RDA RDA bees hee RDB lee a Terminating SG L SG Terminating resistor tT tT en resistor 110Q 110Q Class D Class D Class D Grounding Grounding Grounding RSB CSA CSB The terminating resistor 110Q is built in the multi drop connection module and GOT GT10 GT11 Make sure to set the terminating resistor to both ends of the line For GT15 or GT16 external wiring is required Set the terminating resistor of the GOT that is not at the end of the line to OPEN The terminating resistor 330Q is built in the multi drop connection module and GOT GT10 GT 11 Make sure to set the terminating resistor to both ends of the line For GT15 or GT16 external wiring is required Set the terminating resistor of the GOT that is not at the end of the line to OPEN 7 Troubleshooting In the case where ERROR LED is lit or blinking check the following items Status of ERROR LED Description Check the following items e Check if the power supply status is normal or not e Check the wiring of the connection cable Lit in red ee e Install the correct communication driver e Check if the communication interface to which the cable is connected is correct or not e Check the setting of the RS 422 RS 232 selector switch Check the following items Blinking in red e Check that the Mode sel
23. e Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties e This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life e Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi Electric e This product has been manufactured under strict quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system a MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN HIMEJI WORKS 840 CHIYODA CHO HIMEJI JAPAN JY997D35801C a MITSUBISHI GT01 RS4 M Serial Multi Drop Connection Unit USER S MANUAL Manual Number JY997D35801C This manual describes the specifications of the product Before use read this manual and manuals of relevant products fully to acquire proficiency in handling and operating the product Make sure to learn all the product information safety information and precautions And store this manual in a safe place so that you can take it out and read i
24. ection switch is set to the right e The OS may be faulty Install the standard OS and communication driver from GT Designer2 or GT Designer3 to the multi drop module again This manual confers no industrial property rights or any rights of any other kind nor does it confer any patent licenses Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi opportunity loss or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties e This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life e Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi Electric e This product has been manufactured under strict quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the sys
25. ep Count C60068 2 6 Directly installed Must be free of lamp black corrosive gas flammable gas or excessive amounts of electroconductive dust particles and must not be placed in direct sunlight This applies for storage as well 2000m 6562 ft max Self cooling 90x65x90mm Approx 0 3kg Using DIN rail or fixed with screws Standard color of Mitsubishi Electric Black corresponding to N 0230 BG Conforms to CE 1 Cannot be used under pressures higher than the atmospheric pressure Failure to observe this instruction may cause the unit to fail 3 2 Communication Specifications Item Connection configuration ion standard method D sub 9 pin female Transmission distance can be connected Insulation F4 USB I F1 RS 422 I F2 RS 232 I F3 RS 485 1 Transmissi RS 422 ich RS 232 1ch RS 485 ich USB device ich Transmiss 115 200 57 600 38 400 19 200 9 600 4 800 bps Full Speed 12Mbps Photocoupler insulation D sub 9 pin male oe block attach detach 500m max maximum overall Mini B Receptacle Half duplex and full duplex Communication method Full duplex Can be selected depending on the wiring For PLC connection For PLC connection PC communication 3 4 LED Light Specifications PONER Lit Power is properly supplied Power is not properly supplied Sp Lit Sending the data to PLC Not sending the data to PLC Lit Receiving the data from PLC No
26. ing to the identified standards and design analysis forming a technical construction file to the European Directive for Electromagnetic Compatibility 2004 108 EC when used as directed by the appropriate documentation Type Programmable Controller Open Type Equipment Standard Remark EMI Compliance with all relevant aspects of the EN61131 2 2003 standard Radiated Emissions ee a with all relevant aspects of the Equipment EMS ESD RF electromagnetic field EFTB Surge requirement and tests RF conducted disturbances and Power frequency magnetic field For more details please contact the local Mitsubishi Electric sales site The following manuals are relevant to this product When these loose manuals are required please consult with our local distributor Manual Name GOT1000 Series Connection Manual 1 3 2 3 3 3 Manual Number Model Code SH 080532ENG Describes system configurations of connection methods applicable to GOT1000 1D7M26 series and cable creation methods Description GT Designer2 Version2 Basic Operation Data Transfer Manual SH 080529ENG Describes methods of the GT Designer2 installation operation basic operation for For GOT1000 Series 1D7M24 drawing and transmitting data to GOT1000 series GT Designer2 Version2 Screen Design Manual For GOT1000 Series 1 3 2 3 3 3 GT Designer3 Version1 Screen Design Manual For GOT1000 Series Fundamentals 1D7MB9 Bundled Items Included
27. ller to be connected with GT01 RS4 M and set the details Communication Configuration Close 4 Download the project data For GOT Ej System Environment System Settings Auxiliary Setting System Information Screen Switching S Key Window Dialog Window Communication Settings GOT Setup Language Switching Clock Setting Startup Logo G Handy Got For GOT Controller Setting Controller Setting CH 1 MELSEC QnU 017 a h Network Duplex Setting Manufacturer iy G Redundant 1 F Driver Standard F 1 Security Standard I F 2 Standard F 3 Controller Type MELSEC QnU Q1 nD M NC DR Detail Setting c System Environment IV Use Communication Settings Project Title Standard I F Settings CH No I F Driver Multidrop Slave v Detail Setting 3 gt i Host PC E Detail Setting Cancel Apply Mitsubishi Standard WF RS422 232 Muttidrop Slave Property Value Transmission Speed BPS 115200 Retry Times 0 Timeout Time Sec 3 GOT Address 0 Delay Timefms 0 For instructions on how to download the project data refer to the GT Designer2 Version2 Basic Operation Data Transfer Manual or GT Designer3 Version Screen Design Manual 5 Connect the cable For details of the cable connection refer to the GOT1000 Series Connection Manual 3 Specifications 3 1 General Specifications Ite
28. m Operating ambient temperature Storage ambient temperature Operating Storage ambient humidity Vibration resistance Shock resistance Operating atmosphere Operating altitude Cooling method External dimensions DxWxH Weight Installation method Exterior color Case Standard Specifications 0 to 55 C 20 to 60 C 10 to 90 RH non condensing The wet bulb temperature is 39 C or less Installed with DIN 10to57Hz o 0 0S5mm ceooes 26 oe 2 ee a directions 10 to 57Hz Po 0 075mm Total 80 minutes for each Conforms to JIS C60068 2 27 147 m s 11 ms Sine half wave pulse 3 times each in the X Y and Z directions Sweep Count C60068 2 6 Directly installed Must be free of lamp black corrosive gas flammable gas or excessive amounts of electroconductive dust particles and must not be placed in direct sunlight This applies for storage as well 2000m 6562 ft max Self cooling 90x65x90mm Approx 0 3kg Using DIN rail or fixed with screws Standard color of Mitsubishi Electric Black corresponding to N 0230 BG Conforms to CE 1 Cannot be used under pressures higher than the atmospheric pressure Failure to observe this instruction may cause the unit to fail 3 2 Communication Specifications Item Connection configuration f Transmissi Transmiss on speed ion Insulation standard method D sub 9 pin female I F1 RS 422 I F2 RS 232 I F3 RS 485 1
29. nit power supply section in the specified torque range Undertightening can cause a short circuit or malfunction Overtightening can cause a short circuit or malfunction due to the damage of the screws or the Multi Drop Connection Unit Exercise care to avoid foreign matter such as chips and wire offcuts entering the Multi Drop Connection Unit Not doing so can cause a fire failure or malfunction WIRING PRECAUTIONS CAUTION e Plug the communication cable into the connector of the connected unit and tighten the mounting and terminal screws in the specified torque range Undertightening can cause a short circuit or malfunction Overtightening can cause a short circuit or malfunction due to the damage of the screws or unit STARTUP MAINTENANCE PRECAUTIONS CAUTION e Do not disassemble or modify the Multi Drop Connection Unit Doing so can cause a failure malfunction injury or fire e Do not touch the conductive and electronic parts of the Multi Drop Connection Unit directly Doing so can cause a Multi Drop Connection Unit malfunction or failure e The cables connected to the Multi Drop Connection Unit must be run in ducts or clamped Not doing so can cause the Multi Drop Connection Unit or cable to be damaged due to the dangling motion or accidental pulling of the cables or can cause a malfunction due to a cable connection fault e When unplugging the cable connected to the unit do not hold and pull the cable portion Doing s
30. o can cause the unit or cable to be damaged or can cause a malfunction due to a cable connection fault e Do not drop or apply any impact to the battery If any impact has been applied discard the battery and never use it The battery may be damaged by the drop or impact e Before touching the unit always touch grounded metal etc to discharge static electricity from human body etc Not doing so can cause the Multi Drop Connection Unit to fail malfunction DISPOSAL PRECAUTIONS CAUTION e When disposing of the product handle it as industrial waste TRANSPORTATION PRECAUTIONS CAUTION Make sure to transport the Multi Drop Connection Unit main unit and or relevant unit s in the manner they will not be exposed to the impact exceeding the impact resistance described in the general specifications of this manual as they are precision devices Failure to do so may cause the unit to fail Check if the unit operates correctly after transportation Compliance with EC directive CE Marking This note does not guarantee that an entire mechanical module produced in accordance with the contents of this note will comply with the following standards Compliance to EMC directive for the entire mechanical module should be checked by the user manufacturer For more details please contact the local Mitsubishi Electric sales site Attention This product is designed for use in industrial applications e Manufac
31. on DISPOSAL PRECAUTIONS CAUTION e When disposing of the product handle it as industrial waste TRANSPORTATION PRECAUTIONS CAUTION Make sure to transport the Multi Drop Connection Unit main unit and or relevant unit s in the manner they will not be exposed to the impact exceeding the impact resistance described in the general specifications of this manual as they are precision devices Failure to do so may cause the unit to fail Check if the unit operates correctly after transportation Compliance with EC directive CE Marking This note does not guarantee that an entire mechanical module produced in accordance with the contents of this note will comply with the following standards Compliance to EMC directive for the entire mechanical module should be checked by the user manufacturer For more details please contact the local Mitsubishi Electric sales site Attention e This product is designed for use in industrial applications e Manufactured by Mitsubishi Electric Corporation 2 7 3 Marunouchi Chiyoda ku Tokyo 100 8310 Japan e Manufactured at Mitsubishi Electric Corporation Himeji Works 840 Chiyoda machi Himeji Hyogo 670 8677 Japan e Authorized Representative in the European Community Mitsubishi Electric Europe B V Gothaer Str 8 40880 Ratingen Germany Associated Manuals Requirement for Compliance with EMC directive The following products have shown compliance through direct test
32. p Slave 05 02 50 FREGROL 500 700 05 02 53 OMRON SYSMAC 05 02 53 OMRON THERMAC INPANEL NEO 05 02 53 KEYENCE K 700 1000 05 02 53 KOYO KOSTAC DL 05 02 53 JTEKT TOYOPUC PC 05 02 53 SHARP Jw 05 02 53 a M cumivn TECUMNC CPAOMTONI I CD ME NIEN Total 150 Kbyte Write Drive Information E Data Area Kbyte E Free Space Kbyte OOOOOOO8O00000 lt C Write after deleting all contents in the project folder GOT Write Communication Configuration Info Reception Close Check GT Designer2 or GT Designer3 drive information to know if the OS is properly installed in the GOT For details refer to the GT Designer2 Version2 Basic Operation Data Transfer Manual or GT Designer3 Version Screen Design Manual 3 Set the communication interface e For the multi drop connection module set the communication interface in the communication setting with GT01 RS4 M of GT Designer2 or GT Designers e For the GOT set the communication interface in the Communication Settings of GT Designer2 or GT Designer3 For details refer to the GT Designer2 Version2 Basic Operation Data Transfer Manual or GT Designer3 Version Screen Design Manual For GT Designer2 For multi drop connection module Communicate with GT01 RS4 M Communication configuration Computer gt GTO1 RS4 M OS Computer gt GTO1 RS4 M Comm Param Download setting of Communication parameter
33. reation methods Description GT Designer2 Version2 Basic Operation Data Transfer Manual SH 080529ENG Describes methods of the GT Designer2 installation operation basic operation for For GOT1000 Series 1D7M24 drawing and transmitting data to GOT1000 series GT Designer2 Version2 Screen Design Manual For GOT1000 Series 1 3 2 3 3 3 GT Designer3 Version1 Screen Design Manual For GOT1000 Series Fundamentals 1D7MB9 Bundled Items Included Item GT01 RS4 M main unit Power supply cable with connectors GT01 RS4 M Multi Drop Connection Module User s Manual this manual 1 System Configuration 1 1 System Configuration GOT multi drop connection is a communication method for 1 N communication by connecting multiple GOTs to one PLC using the GT01 RS4 M serial multi drop connection module e GT Designer2 e GT Designer3 Communication driver e Communication interface e Communication driver e Communication interface Serial multi drop connection module Varies according to the connection type RS 485 cable Kk 1 2 Compatible PLC For PLCs compatible with the GOT multi drop connection refer to the GOT1000 Series Connection Manual ar Describes specifications and settings of the object functions used in GT Designer2 SH 080866ENG Describes methods of the GT Designer3 installation operation basic operation for drawing and transmitting data to GOT1000 series Number of Items
34. rnal Dimensions and Part name No 1 2 3 4 5 6 7 8 9 10 11 12 1 e Protective cover is installed alt LED TNE s MITSUBISHI GT01 RS4 M O POWER ORD O sD O ERROR Terminating resistor selector Connector for PLC communication USB port Connector for PLC communication Protective cover Power supply connector Slider for installing the DIN rail for RS 232 connection Connector selection switch for PLC communication for RS Mode selection switch Slide switch 422 connection Terminal block for the serial multi drop communication Description Power is properly supplied Power is not properly supplied Sending the data to PLC Not sending the data to PLC Receiving the data from PLC Not receiving the data from PLC No error Communication error with PLC Multi drop communication error e Protective cover is removed MITSUBISHI GT01 RS4 M 5 RS 232 8 T O ERROR 3 0 10Q RS 232 IFS we M D Specifications Installation hole Lit in green when the power is properly supplied Lit in green when the data is being sent to PLC Lit in green when the data is being received from PLC Lit or blinking depending on the status Can be selected among 1109 OPEN and 3302 set to OPEN by default D sub 9 pin male Switch for selecting RS 422 or RS
35. t whenever necessary Always forward it to the end user Registration The company name and the product name to be described in this manual are the registered trademarks or trademarks of each company Effective Oct 2009 Specifications are subject to change without notice 2009 Mitsubishi Electric Corporation Changes for the Better GRAPHIC OPERATION TERMINAL GOTOO Safety Precaution Read these precautions before using Before using this product please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly The precautions given in this manual are concerned with this product In this manual the safety precautions are ranked as DANGER and CAUTION Indicates that incorrect handling may cause hazardous lt gt DANGER conditions resulting in death or severe injury Indicates that incorrect handling may cause hazardous CAUTION conditions resulting in medium or slight personal injury or physical damage Depending on circumstances procedures indicated by CAUTION may also be linked to serious results In any case it is important to follow the directions for usage DESIGN PRECAUTIONS DANGER e Some failures of the Multi Drop Connection Unit or cable may keep the outputs on or off An external monitoring circuit should be provided to check for output signals which may lead to a serious accident Not doing so c
36. t receiving the data from PLC ERROR Communication error with PLC Multi drop communication error For details of corrective actions refer to Chapter 7 Troubleshooting 4 External Dimensions and Part name 1 aw Protective cover is installed f6 MITSUBISHI GTO1 RS4M e Protective cover is removed MITSUBISHI GT01 RS4 M 5 SJ esr RS 0 pe jie rcs H Oh RS 232 O POWER ORD O sD RS 232 S O POWER ORD O sD O ERROR O ERROR 90 Application Cannot be used simultaneously Cannot be used simultaneously For multi drop connection l l No Specifications with I F2 with I F1 OS installation i 1 Installation hole for the main unit Installation hole 3 3 Power Supply Specifications Lit in green when the power is properly supplied Item Specifications 2 LED Lit in green when the data is being sent to PLC Input power supply voltage 24VDC 10 15 Lit in green when the data is being received from PLC Fuse built in not exchangeable 1A Lit or blinking depending on the status Power consumption 3 36W or less 140mA 24VDC 3 Terminating resistor selector Can be selected among 1102 OPEN and 3302 set to OPEN by default Inrush current 14A or less 24VDC 2ms 4 Connector for PLC communication for RS
37. tem afa MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN HIMEJI WORKS 840 CHIYODA CHO HIMEJI JAPAN
38. tured by Mitsubishi Electric Corporation 2 7 3 Marunouchi Chiyoda ku Tokyo 100 8310 Japan e Manufactured at Mitsubishi Electric Corporation Himeji Works 840 Chiyoda machi Himeji Hyogo 670 8677 Japan e Authorized Representative in the European Community Mitsubishi Electric Europe B V Gothaer Str 8 40880 Ratingen Germany Associated Manuals Requirement for Compliance with EMC directive The following products have shown compliance through direct testing to the identified standards and design analysis forming a technical construction file to the European Directive for Electromagnetic Compatibility 2004 108 EC when used as directed by the appropriate documentation Type Programmable Controller Open Type Equipment Standard Remark EMI Compliance with all relevant aspects of the EN61131 2 2003 standard Radiated Emissions ee a with all relevant aspects of the Equipment EMS ESD RF electromagnetic field EFTB Surge requirement and tests RF conducted disturbances and Power frequency magnetic field For more details please contact the local Mitsubishi Electric sales site The following manuals are relevant to this product When these loose manuals are required please consult with our local distributor Manual Name GOT1000 Series Connection Manual 1 3 2 3 3 3 Manual Number Model Code SH 080532ENG Describes system configurations of connection methods applicable to GOT1000 1D7M26 series and cable c