Home
ProfiTrace 2.9.2 User Manual
Contents
1. Fig 13 ProfiTrace start up screen After clicking on Init ProfiCore Ultra The ProfiTrace software 1 Detects if ProfiCore Ultra is connected to the USB port 2 Checks if the required license has been installed 3 Scans the baudrate of the network After the baudrate has been detected the Live List and the detected baudrate as in Fig 14 should be visible ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 37 150 5 3 ProfiTrace for ProfiCore Ultra V2 1 c 2004 2008 PROCENTEC ProfiCore Ser Nr xxx 400002 UE em Lis ED ES HS FA CCE Fig 14 Live List after initialization 2 g ProfiTrace for ProfiCore Ultra V2 1 c 2004 2008 PROCENTEC ProfiCore Ser Nr xxxx 00002 Fig 15 Navigating in ProfiTrace ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC From this point the software can be easily navigated to different modes by just clicking on its representing tab see Fig 15 e ProfiTrace Live List Statistics Message Recording and Data Inspection e ScopeWare Advanced oscilloscope designed for PROFIBUS signals e Bar graph Indicator for general health of stations e Topology scan T
2. 46 5 4 Network Condition Indicator eeeesseeeeseeeeeeeenn nennen nennen enne nennt esent nennen 46 on E soe 47 o WEM 4 nimmt 48 Sod Bar erap h MOES enine aen nn nen eo MEME MM MM EMEN MR UEM E 50 ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 5 7 WO DOOLEY CAR a D Dvd Se quU NoD IU NEM en a 51 5 7 1 Restrictions for using the topology SCAN ss 51 CER CIO MEAE IE o a aa ne ee 52 a OCT aly ives mtm 52 5 10 Report generation ccesccsseccssccesscessccescceseccseecesscesecseeceseceseesaeeceseceaeeseeseeaeceaeeseeseeasesaessesseeaeetaes 54 6 Message and file recording nmm ne nenne nn rrr nnne enne nenne nns 56 bL Message CORRE pe Se bdsm ed en UN ME 57 bl JABSnUgB CO HE cand quist aa a ee ee 59 Gale POP COS a aa Ed Rua Ei Dimas bise DRbI CHI E ae e facea R RE UE 60 6 1 3 Service column for rEQUESTS cccccccccsssecccceeesecceceeeseccceeeeeceeseeeeceeseueseeseseueeeeesseeeeeesseueeseesseees 60 6 1 4 Service column for responses 2 subissasasxkbs Sev 2IN PS Aga VF ogFEOFiAIROG RIVE MR RM MET EPA FAO Sa Ra dRE MEE GE 61 ELS MSS TUDS VOI P Su seite dts mE im ree eRe EM CMS INE EMEN 62 5 2 Fi CON IS ee DN Rr one 63 ra Network Condition Indicator ssssssssse ee emen nennen nennen nnns 65 7 1 Measurement time and reset button sise 65 7 2 PROFIBUS Traffic Light and warnings icons skvsseens ks eEeu RT pk EASY EXNYENEPUE YREXN PECES NEVER uS DIVOS SU
3. Prof User Manual Safety Guidelines This manual contains notices which you should observe to ensure your own personal safety as well as to protect the product and connected equipment These notices are highlighted in the manual by a warning sign and are marked as follows according to the level of danger Draws your attention to important information on handling the product a particular part of the D documentation or the correct functioning of the product Warning This device and its components may only be used for the applications described in this manual and only in connection with devices or components that comply with PROFIBUS and RS 485 interface This product can only function correctly and safely if it is transported stored set up installed operated and maintained as recommended The ProfiCore Ultra is a CE class A product In a domestic environment it may cause radio interference in which case the user may be required to take adequate measures Warranty Warranty is void if you open ProfiCore Ultra Disclaimer of Liability We have checked the contents of this manual as much as possible Since deviations cannot be precluded entirely we cannot guarantee full agreement However the content in this manual is reviewed regularly and necessary corrections will be included in subsequent editions Suggestions for improvements are welcome Copyright 2011 2015 PROCENTEC All rights reserved No part of this publication may be
4. Info amp Setup Di Setthe address Standard setting Address 2 i eive v WatchDog Enabled Device information from GSD Vendor Name WAGO Kontakttechnik GmbH Model Name 750 333 WAGO Ident Nr OxB 754 Hardware release Hw 01 Software release S w 01 Filename W agob 754 gsd Setup Modules amp Parameters A ssignmen BEN EM M Setu p the E m B Color coded state Steal Slave Address selection dialog x modules here Color coded slave state ib Current steal address 32 Standard amp enhanced diagnostic and status information Address 32 v cM Lok ro Additional features aster Loc eactivate Enabled Parameter Fault reserved Steal Slave v noie Invalid slave response Sync mode active Feature not Supported Freeze mode active Cancel Apply Ext diag bit Watchdog is on Configuration fault Station is slave Station not ready Static diagnostics Steal the slave Confirms the v Station not existent Parameter request Confirms the settings from a running master Ok Cancel settings verflow Select the address followed by Setup the Modules amp Parameters GSD Configuration dialog c 2003 2005 PROFIBUS Center Netherlands V1 3 2 ej Module Selection User Parameters Module Parameters Standard keywords Selected modules Sk Name inputs Dupuis Module Prm IAddr Joada f Remove Selected Modul
5. v5 0 0 27 January 2015 PROCENTEC 105 150 15 Training This chapter contains some exercises to enhance the practical knowledge of ProfiTrace 2 In order to do these exercises it is required to connect ProfiTrace to a working installation or training kit with a class 1 DP master that has at least 2 slave devices in Data Exchange It is not recommended to do these exercises on an installation that is running a real production process For the ProfiCaptain exercises a full license is required Recommended busparameters e 1 5Mbps e HSA 126 e Retries 5 15 1 First steps ASSIGNMENT 1 SOFTWARE INSTALLATION Install the ProfiTrace software on the PC Laptop Copy Install the required license file s in the C ProgramData procentec proficoreultra or APP directory Copy the required GSD files to the GSD directory of ProfiTrace Connect the ProfiCore Ultra to the PC Laptop Connect the ProfiCore Ultra to the installation check first if the termination is OFF on the Tap Connector ESL Se ES Test the installation by starting the software and click on Init ProfiCore When the software is running the Live List of the PROFIBUS Installation should be visible Select the preferred language Scan the GSD files in ProfiTrace Generate the catalogue in ProfiCaptain Check the Live List by switching the PLC ON OFF if device names are missing locate and install the required GSD files EE RETE LER LR Close
6. 32 V Fig 46 AC and DC measurement ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 76 150 11 Network Manager The Network Manager is a tool to save and load oscilloscope measurements bar graphs and topology images You can use it to assign names to segments measurement points and stations These names will appear in the Report The Network Manager is particularly helpful when measuring a network with multiple segments These segments can be divided by repeaters hubs fiber optic couplers or other media converters It also helps analysing the oscilloscope measurements by showing min max values Important As soon as the ProfiCore Ultra is initialized the Network Manager captures electrical measurements This is a continuous background process It is important to keep this in mind especially when changing the location of the ProfiCore Ultra You can stop the measurement recording at any time by clicking Stop processing 11 1 Edit station properties The Network Manager is divided in two main windows a segment tree and segment details measurements To view the current segment make sure the ProfiCore Ultra is initialized and attached to the beginning of the segment that you wish to manage Then click Show list see Fig 47 This automatically generates a complete list of connected stations Note that ALL stations in the entire network are listed also stations in other segme
7. Info Panel Plugins Scan GSD WMary Jose ProfiCare Ue DEC Da diae Y Livelst EJ Messages S Messages with view fter applied Station statistics view O Data inspection Click Settings followed by Preferences to proceed x General Message header selection Message display settings Live list settings Live list colors Scopew are Color Background AB Differential Madify Ato ISO Modify B to ISO Modify Grid division line Modify Cursors Madify Cancel Reset to defaults Click on ScopeWare to set the oscilloscope colours For presentations it is recommended to set the AB Differential colour to Yellow If you want to adjust the Live List colours click on Live List colours ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 3 12 Upgrades It is the policy of PROCENTEC to release periodic upgrades These upgrades do NOT overwrite the previous version If you do not want to use the previous version anymore you can follow this procedure L Uninstall the previous version by means of the Control panel in Windows L Rename or move the directory of the previous version to a more suitable name location L Install the new version on top of the directory from the previous version If you are confronted with a warning about existing drivers which seems to be newer see Fig 4 just click Yes and overwrite them Update the shortcut on t
8. PROCENTEC 102 150 14 CommDIM The ProfiCore Ultra features a fully functional gateway between any Windows platform and field devices using a CommDTM This enables the ProfiCore Ultra to function as a real Asset Management tool Currently we support FDT 1 2 frame applications such as PACTware and E H FieldCare During interaction with the CommDTM all ProfiTrace functions can be used simultaneously monitoring oscilloscoping DP master and OPC If you are using Siemens EDD files you can convert these to DTM files using a tool called Sitrans DTM More information can be found on www siemens com sitransdtm 14 1 Installing the drivers and DTM server Download the latest CommDTM files from the software section on www procentec com The file is called CommDTM Base Installer zip Install the files in this ZIP GQ id CommDTM Base Installer zip Organize Extract all files sir P Name Type Compressed size Password EE Desktop E CommDTM_Installer exe Application 4061 KB Mo 4108 KB 4 Jg Downloads E PCD Installer exe Application 3 528 KB No 3 708 KB 5 1s Dropbox SEN is Recent Places Desktop A Libraries ES Documents al Music El Di turec 2 items State BB Shared Or 4 To check if the CommDTM files have installed correctly verify if you have the following directories in your Program Files folder e PROCENTEC e DP V1 CommDTM e PCD Then connect the ProfiCore Ultra to the US
9. Updated screenshots Updated the Testlab certificate Version 5 0 0 Changed address Changed manual into new template Added paragraph File recording Minor textual changes ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 136 150 26 Next versions Chapter updates e Full revision of all chapters e Reporting e PA signal examples e Table with file extensions e ProfiCaptain DP V1 e Saving ProfiCaptain projects e Rotating message buffer e Paragraph describing all settings and preferences ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 137 150 27 Sales offices and Distributors HEADQUARTERS PROCENTEC Klopperman 16 2292 JD WATERINGEN Netherlands ARGENTINA eFALCOM Alcorta 2411 B1744 Moreno Buenos Aires Argentina AUSTRALIA IS Systems Pty Limited 14 Laverick Ave Tomago NSW Australia 2322 Pentair Flow Control Pacific 1 Percival Road Smithfield NSW Australia 2164 BELGIUM and LUXEMBOURG Bintz Technics N V Brixtonlaan 23 B 1930 Zaventem Belgium BRAZIL Westcon Instrument Indl Ltda Rual Alvaro Rodrigues 257 S o Paulo SP Brazil CEP 04582 000 CANADA Streamline Process Management Inc 43 4351 104 Ave SE Calgary Alberta T2C 5C6 Canada CHILE RP Ingenieria Limitada Tucapel 92 oficina 52 Concepci n Chile CHINA PROCENTEC Beijing Room E 1115 WangJingYuan YouLeHui ChaoYang Bei
10. 2 0V Grey bar due to 1 0V station inactivity 0 0v Fig 26 Inactive station in Bar Graph 5 6 1 Bargraph Modes The Bar graph has 2 modes e AB Differential voltage e AB Diff stable voltage AB Differential voltage is the average amplitude of the signal and AB Diff stable voltage is the minimum measured amplitude seem eee eee eh eee ee pee ee ee ee eee BB ee mom m mom mom mom m m m m m m m om om m om mom um wm m wm mo momo momo momo mom mom mom qm ee AB Differential voltage average AB Dif stable voltage eee ee eee ee ee hp eee ee ee pe ee be ee ee Be ee eg eee ee ee o o a ee eee Meas range 20 80 Meas range 20 60 1 bit 1 bit Fig 27 Measurement principle of the Bar graph modes ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 50 150 AB Differential voltage The average voltage of the 1 part and 0 part is determined The difference in voltage is the AB Differential voltage This mode is useful to see if the general voltage of a device is not too low maybe caused by long cable wrong cable or a faulty bus interface AB Diff stable voltage The lowest voltage of the 1 part is determined and the highest voltage of the 0 part is determined The difference is the AB Diff stable voltage This mode is useful to detect reflections on the bus that might corrupt the integrity of the signals bit interpretation Missing terminators can cause the
11. ASSIGNMENT 1 REGULAR SITUATION L Make sure the installation works properly without physical problems E Analyze the AB differential and AB Diff Stable Voltage Are they the same E Insert additional cable between the last 2 devices Analyze a difference in the Bar graph L Sort the signals on high to low Voltage and compare this with the drawings of the installation ASSIGNMENT 2 TERMINATION MISSING Remove a termination and investigate the AB differential and AB Diff Stable Voltage ASSIGNMENT 3 SHORT CIRCUIT Create a short circuit between A and B and investigate the AB differential and AB Diff Stable Voltage 15 8 Report generation ASSIGNMENT 1 INSTALLATION WITH FAULTS Generate a report of an installation with faults and investigate the results include your company logo ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 112 150 ASSIGNMENT 2 INSTALLATION WITHOUT FAULTS m Generate a report of an installation without faults and investigate the results including your company logo 15 9 ProfiCaptain ASSIGNMENT 1 NETWORK SCAN IN A MULTI MASTER NETWORK Clean the Live List in ProfiTrace only addresses of the device visible Perform an automatic baudrate detection in ProfiCaptain If the detected baudrate suggested master address and busparameters look acceptable enter the Stop mode operate mode is preferred Verify this new master in the Live List of ProfiTrace Pe
12. Edit OPC Tag After setting up the OPC tags the server has to be activated The OPC server settings can be found in the Settings menu see Fig 51 In the next dialog the server can be added see Fig 52 Maximum 16 servers can be created each with its own tag groups ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 100 150 jProfiTrace for ProfiCore Ultra V2 5 c 2004 2010 PROCENTEC Fig 51 OPC server in the Settings menu m FOPC servers configuration lt none gt Fig 52 Adding the OPC server ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 101 150 In the next dialog the properties of the server are set up see Fig 53 Give it a proper name and indicate if you want to use the default tags or the PTO file with the user defined tags It is also possible to link the OPC server to a certain ProfiCore By default it is set to all When the settings are completed click close and the OPC server will be active In later stages the OPC server settings can be modified IOPC servers configuration ame ProfiTrace OPC Server t Fig 53 OPC server properties From this point any application that has the availability of an OPC client can access the ProfiTrace OPC tags ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015
13. Reset this statistic This resets ONLY this statistic for ALL stations to O e Reset all This button resets ALL statistics for ALL stations to O 5 3 3 Message recording The absolute truth When the user records messages he has a perfect visual representation on the screen see Fig 19 and Fig 20 In the preferences menu the columns and timing units can be set After the scanning of the GSD files it is also possible to inspect process values and see diagnostic information in understandable text in the info panel All the other basic busmonitor features such as logging file management search functions etc are supported ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 44 150 Ed ProfiTrace 2 for ProfiCore Ultra V2 0 beta c 2004 2007 PROCENTEC File Action Filter Trigger Toolbars View Report Settings Help ProfiTrace ScopeWare Bar graph Network Manager ProfiCaptain Load Data Save Data File viewer Setup ra Search Option to inspect Init Praficore Ultra Close ProfiCore Ultra Auto detect f A unctions raw messages System activity Live list Message recording X N Info Panel V Livelist E ages amp Messages with view filte GU Station statistics view JO Data inspection Framestructure SD1 message Source address 3 Destination address 6 Model Name JK161DP ACHI Fisif tipe Hequest wex aQe 38141 21 Nov 2007 10 35
14. 121 150 21 Frequently asked questions I m looking for a document that describes what is a bad and good signal The ProfiTrace 2 manual contains all kinds of example measurements wire breaks short circuits stub lines etc that can be compared with the real situation Please download it from our website Can get a trigger signal for an external oscilloscope from Proficore Ultra YES ProfiCore Ultra still allows you to connect an external oscilloscope But we prefer you to use the ScopeWare which makes electrical measurements much easier Sometimes ProfiTrace cannot detect the baudrate When set it to manual it works What is the solution to solve this problem Sometimes the combination PC ProfiCore and PROFIBUS can make it difficult for the software to detect the baudrate This has to do with a certain timeout This timeout can be set in Settings gt Preferences gt General Here you find the timeout for the baudrate detection Set it to a higher value and in most cases this will solve the problem Which GSD file version is supported by ProfiTrace ProfiTrace and ProfiCaptain support GSD file version 3 Any unknown entries in the GSD file are ignored higher GSD file versions What happens if you switch on the termination of the Tapconnector You will have 3 terminators in the segment and that could cause data communication problems The reason we have it is described in the Topology scan part of the FAQs Operating systems
15. A PIa Mpe Oean da a nn ma ne Cine 111 LRO OO eC 6 de a ee ee De 111 ELI ce m 112 IE REDO SEMEL ES na OO 112 KS PoC RERO m 113 Tips and tricks iii esen nne nnne n nnns n rrr re enne enne nn 114 16 1 Checklist to prepare your installation sisi 114 16 2 Checklist to create a reliable installation ss 115 16 3 How can self test ProfiTrace and the ProfiCore Ultra esssesssseseeseseereserresrrrererrereererrereserreseee 115 16 4 ProfiTrace and ProfiCaptain secrets saisine sracteutrensctecesasa eedeansanssestastieatet cciestares 116 Tecnica dala ProCare irc 117 Technical data PA Probe Ultra essssee eene 119 Technical data Tap Connector iii 120 Wis m TEITE I D de ail D dal AA 121 Frequently asked questions iii 122 Proce amne a on 127 Contents of the Troubleshooting Toolkit eessssssssssrrrrrrrireeeesssssssrrrrrrrrrrrrrrrereesserrrrrrrrn 129 fiaccr T 130 Bre VISION ISON IE A E E N E E A N CQ d osi epi Ces Dop dubi n trente i Ub desi dapi dup idus d buo d dfiids 136 Hu uU ESL uuu EPUM HI EECEEED IEEE PEEEDUR 137 Sales offices and Distributors esssssssessseee eee enne ener 138 pertum es LN NR m 143 AE eoo PRETI K 144 Dg Luth saaisaassaessancdapsdanabanatasatusabesabenbhanseabnbabibanihapsbapabapahipabenabanibagebapabaniaadees 147 ProfiTrace 2 9 2 User Manual v5 0 0 27 January 201
16. Assign a name for example End of segment at slave x ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 80 150 This measuring point is currently not recording any signals First you need to activate the measuring point either by choosing if from the Current Segment drop down list or right clicking it and choose Set as current Segment 1 measurement point Now you will see a flashing red X before it Current Measuring point Also note that Auto add stations is automatically un checked ny End of segment at slave Start of segment at master 3 Then un check Stop Processing which enables the Network End of segment at slave 25 Manager to capture signals again Check Auto add stations and click on Show List If you do not see all stations appearing you may need to wait for a few seconds to allow the Network Manager to capture signals of all stations Hit Show list again to update the ES Segment 1 list EE Start af segment at master 3 A 3 Master Auto add stations M Stop Processing Important Changing the current measuring point will automatically activate the Stop Processing function to secure previously recorded measurements Always verify if the correct measuring point is selected before disabling the checkbox 11 7 Creating a new segment If your PROFIBUS network consists of more than one segment due to repeaters hubs fiber optic
17. Ident Number D 1503 Bitmap EH1503 N Fig 29 ProfiCaptain configuration utility It is very easy to watch and manipulate 1 0 If needed class 2 functions and DP V1 services can be applied on all devices in the network even when they are not configured or belong to another master see Fig 30 Z 4 ProfiTrace II for ProfiCore Ultra c 2004 2007 PROCENTEC 1 11 Deltapilot S Stellungsregler TZID F Stratos 222n X Series Temperatur Messumformer T TF12 ABB Transmitter 1 Al PhyL 0 c Transmitter 1 Al PhyL 1 Transmitter AF800 GSD Filename EH3X1503 GSD Vendor Name Endress Hauser Model Name Deltapilot 5 2nd Generation Ident Number Dx1503 Bitmap EH1503 N Fig 30 ProfiCaptain special functions ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 5 10 Report generation We ve got proof The reporting feature creates a detailed report that contains the electrical signals of all devices their faults the network topology bar graph and administrative information On the front page it provides a conclusion if the installation is approved or not Click on Report to start the report generation See Fig 31 After filling in some administrative information the report is generated immediately The results can be printed to any installed printer driver also PDF Fig 32 Shows a screenshot of the first page of a re
18. Program FilessProfiTrace V2 0 2 Napp sgsdXEH 1501 GSD results Errors 0 Warnings 4 Rev 2 Filename C Program Files ProfiTrace_ V2_0_2 app qsd EURO2400 GSD results Errors 0 Warnings 1 Rev Filename C Program Files ProfiTrace_V2_0_2 app gsd MELCF232 GSD results Errors 0 Warnings 0 Rev 1 Filename C Program Files ProfiTrace_V 2_0_2 app qsd MT12F037 GSD results Errors 0 Warnings 9 Rev 1 Filename C Program Files ProfiT race_Y2_0_2 app gsd SIEM8028 GSD results Errors 0 Warnings 12 Rev 1 Filename C Program Files ProfiTrace_V 2_0_2 app gsd SIP1804B GSD results Errors 0 Warnings 4 Rev 1 Filename C Documents and Settings GSD 0V10F232 GSD results Errors 0 Warnings 0 Rev 1 Filename C Documents and Settings GSD 5800B4S GSD results Errors 0 Warnings 6 Rev 1 Filename C Documents and Settings GSD amp BB 0098 GSD results Errors 0 Warnings 0 Rev 2 Filename C Documents and Settings GSD ABB_0043 GSD results Errors 0 Warnings 1 Rev Filename C Documents and Settings GSD Abb_04c2 gsd results Errors 0 Warnings 0 Rev 2 Filename C Documents and Settings GSD ABB_04c4 GSD results Errors Warnings 7 Rev 2 Filename C Documents and Settings GSD 4BB 0528 asd results Errors 0 warnings 0 Rev 2 Filename C Documents and Settings GSD ABB_0535 GSD results Errors 0 Warnings 2 Rev Filename C Documents and Settings GSD A4BB_0815 GSD results Errors
19. drivers and installation Topology scan hangs in a Windows 7 environment How can I solve this Select Windows XP in the compatibility properties of ProfiTrace Can I install ProfiTrace 2 next to ProfiTrace 1 YES it uses another default installation directory and the drivers are different You can even run both applications at the same time Can I run ProfiTrace 2 on a Windows 2000 system This depends on 2 factors the performance and the system has to be equipped with high speed USB 2 0 ports Can I run ProfiTrace 2 on a Windows Vista system It might be necessary to run in Windows XP Compatibility mode You can set this in the properties of the exe file Can I run ProfiTrace 2 on a Windows7 system Yes version 2 4 and later provides drivers to run ProfiTrace on Windows7 systems ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 122 150 Topology scan Will the Topology scan be able to scan through repeaters NO You will not be able to scan through repeaters but you can clearly see which devices are behind a repeater because the cable length between them will be O m Can the Topology scan create a network drawing of the Profibus PA network At the moment it is only RS 485 DP For PA it will be very difficult due to junction boxes and Ex barriers How can exclude participants before starting the Topology Scan In the Network Manager you can create segments by adding repeaters to the network and dividi
20. vital statistics 0 Days 0 41 37 100 0 Colours indicate the state of the network Profibus Warnings ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 5 5 ScopeWare he easiest oscilloscope ever The ScopeWare is a real time oscilloscope for the inspection of the signal quality After selecting this tab the first time after starting ProfiTrace the oscilloscope runs immediately in differential mode displaying all signals that are measured see Fig 21 The time base and voltage levels can easily be adjusted The screen refresh can be halted by clicking on freeze By double clicking on the devices in the Live List the oscilloscope triggers on the respective device and only displays its signals This is a perfect mode to inspect the signal quality for individual devices To display cursors for level and time analysis click on cursors To have the oscilloscope carry out an A and B measurement select mode The oscilloscope will now display the A and B line separately A powerful feature of the oscilloscope is the Bit Interpretation Engine It displays the bits that ProfiTrace detects on the bus The end user can compare this with the signals that are measured with the oscilloscope and make a judgment about the signal quality see Fig 22 e Profitrace for ProfiCore Ultra V2 1 c 2004 2 File Action Filter Trigger Toolbars View Repo Freezing the ProfiTrace ScopeWare
21. 0x80 00000101 0x00 0 00001 0 Good NC 0k Ok 14 114258 Good NCVOKk Ok 0 000010 Gocd NC 0k 0k 0 083543 Good NC 0k 0k b10111101 00000000 b00000000 00000001 00000000 00000000 10 on f f D L Temperature 1 Temperature 2 Temperature 3 Pressure 1 Control value Status Readback Stahus Process value 1 Process value 2 Process value 3 Flow Digital 1 0 Digital 1 0 Offsetin the message Dar Captured data 00 19 00 00 00 00 00 00 OO 00 19 5 4 Network Condition Indicator The Network Condition Indicator Overview tab gives a general idea of the health of the PROFIBUS system A traffic light indicates if the PROFIBUS network is OK green has problems but still runs yellow or has problems needing urgent attention red The overview features a summary of the most important ProfiTrace statistics These are updated real time In the Network Condition Indicator Details you find warnings generated by ProfiTrace based on electrical or telegram faults Measurement starte ENTEC ProfiCore Ser Nr 00000013 brt Settings Help ProfiT raco T Uv A timer shows how long the measurement has reset OERE been running and percentages next to each traffic light colour indicates how much time the network has been in that state Percentage of colour state versus total measurement time 0 Days 0 41 37 0 Days 0 00 00 0 0 0 Days 0 00 00 0 0 Fastest Input change Summary of
22. 1 3 Application areas e Troubleshooting amp maintenance of PROFIBUS networks ProfiTrace ScopeWare Topology scan and ProfiCaptain e Commissioning of PROFIBUS networks ProfiTrace ScopeWare Topology scan and ProfiCaptain e PROFIBUS product testing and verification ProfiTrace ScopeWare ProfiCaptain and CommDTM e Passive cable testing ScopeWare and ProfiCaptain e 1 0 testing of PROFIBUS devices ProfiCaptain e Setting up and diagnose PROFIBUS devices CommDTM e Address setting of PROFIBUS devices ProfiCaptain e Interface for bus statistics and device 1 0 to external apps OPC server e Education ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 1 4 Detectable faults on PROFIBUS DP ProfiTrace 2 can be used to detect almost all faults in PROFIBUS DP networks The table below describes the sub programs you need to find specific faults Faults on DP Passive cable No master active Running No devices connected Slaves are connected installation General communication ProfiCaptain ProfiTrace ProfiTrace faults Double address ProfiCaptain ProfiTrace ProfiTrace Wrong address ProfiCaptain ProfiTrace Missing device ProfiCaptain ProfiTrace Device diagnostics ProfiCaptain ProfiTrace Configuration faults ProfiCaptain ProfiTrace No termination ProfiCaptain ScopeWare ProfiCaptain ScopeWare ScopeWare Too many termination ProfiCaptain ScopeWare ProfiCaptain ScopeWare ScopeWare Powerless terminat
23. 38 555 SD2 3 gt 10 SRD HIGH Data Exchange 38142 21 Nov 2007 10 35 38 556 SD2 3 lt 10 BE pete Exchange is 1i PROFIBUS DPVO Message 38143 21 Nov 2007 10 35 38 556 SD2 3 gt 32 SRD HIGH Data Exchange Req 2 Data Exchange 38144 21 Nov 2007 10 35 38 556 SD2 3 32 DL ce Exchange Res 38145 21 Nov 2007 10 35 38 556 sD1 3 104 FDL Status Req 38146 21 Nov 2007 10 35 38 556 SD4 3 3 Token pass Pass token 38147 21 Nov 2007 10 35 38 556 sD2 3 gt 27 SRD HIGH Date Exchange Req 4 38148 21 Nov 2007 10 35 38 556 ACK DI Short acknowledge Res 38143 21 Nov 2007 10 35 38 556 SD1 3 gt 6 SRD HIGH Data Exchange Req 21 Nov 2007 10 35 38 557 Repeat SD1 3 76 SRD HIGH Data Exchange Req Info panel With 21 Nov 2007 10 35 38 557 Repeat SD1 3 gt 6 SRD HIGH Data Exchange Reg 21 Nov 2007 10 35 38 557 Repeat SD1 3 gt 6 SRD HIGH Data Exchange Req more information 21 Nov 2007 10 35 38 557 Repeat SD1 3 76 SRD HIGH Data Exchange Req 21 Nov 2007 10 35 38 558 Repeat lost SD1 3 gt 6 SRD_HIGH Date Exchange Req 21 Nov 2007 10 35 38 558 SD2 3 gt 43 SRD HIGH Data Exchange Req 2 21 Nov 2007 10 35 38 558 SD2 3 lt 43 DE ta Exchange Res 2 21 Nov 2007 10 35 38 558 SD2 3 gt 10 SRD HIGH Data Exchange Req rif 21 Nov 2007 10 35 38 558 SD2 3 lt 10 B ta Exchange Res 1i 21 Nov 2007 10 35 38 55 SD2 3 32 SRD HIGH Data Exchange Req 2 21 Nov 2007 10 35 38 5 SD2 3 lt 32 pate Exchange Res 21 Nov 2007 SD1 3 gt 105 FDL Status Req 2 5D4 3 gt 3 Token pass Pass token 2 SD2 3 gt 27 SRD HIGH D
24. 504 FE Short Act Address gt Trigger im US PARES IS ASA Trigg Freeze Cursors active 5 bit markers CheckBox2 Trigger delay j Reset nas TE M Leveltigger IV Hising edge 4 1 3B Detected glitch E i Hy WEM pa ME Cycle through devices oe Fig 44 EMC EMI disturbances Profilrace for ProfiCore Ultra V2 4 c 2004 2009 PROCENTEC muenchen EMV ptd ProfiCore Ser Nr x xxx06577 Datei Aktion Filter Trigger Toolbars Ansicht Bericht Einstellungen Hilfe ProfiTrace ScopeWare Balkendiagramm Topologie Netzwerk Manager ProfiCaptain Mode HEA v B A Diff scale 1V Div Zeitskala 5 uSec Y zn Adresse 26 Trigger Framing Paritatsfehler x P Einfrieren Aktive Cursor Trigger Delay Trigger delay zur cksetzen Iv Titel Inhalt Detected glitch in the signalling ET O Zyklus durch Ger te EN au Fig 45 EMC EMI disturbances ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 10 Oscilloscope measurements MBP PA With PROFIBUS PA the focus is more on the analysis of AC and DC signals We want to know if the DC level is stable and if the quality of the AC signals is acceptable compared with the noise on the cable 10 1 Acceptable signals When the PA Probe Ultra is connected directly on the DP PA coupler the DC Voltage should be constant and between 12 V to 32 V dependan
25. Bus Monitor Example ProfiTrace Bit Time TBit To help simplify timing calculations it is convenient to normalize the time units One Bit Time is the time it takes to transmit one bit and is the reciprocal of the baudrate and is calculated as follows TBit 1 bit baudrate bps Examples 12 Mbps gt TBit 83 ns 1 5 Mbps gt TBit 667 ns Busparameters Settings that define the timing behaviour on the bus They are defined in the master Examples Tslot MaxTSDR C Capacitance Class 1 master A class 1 master is normally a PLC or DCS system The class 1 master handles the cyclical Data Exchange with the slaves assigned to it Class 2 master A class 2 master is usually a laptop or programming console that is provided for commissioning maintenance or diagnostic purposes Data Exchange The state of a slave after parameterization and configuration has been completed in which it cyclically exchanges 1 0 data with the master Normally the slave stays forever in Data Exchange until the bus communication or device are stopped DGND Digital Ground DIN German Institute for Standardization www din de DP VO DP VO is the basic stage of the PROFIBUS DP communication protocol DP VO devices master and slaves perform the following basic functionalities Cyclic exchange of I O data between controlling and slave devices Device Identifier module and Channel related Diagnosis Parameterization of DP slaves Configurat
26. Ho Chi Minh City Vietnam For the up to date list of the Sales Offices and Distributors see www procentec com company distributors se Ino zomm on Sr d 44 2890 777743 44 2890 777794 jgillan parkelect co uk www parkelect co uk 1 630 245 1445 1 630 245 1717 sales gridconnect com www gridconnect com procentec html 84 8 3547 0976 84 8 3547 0977 hai hoang bavitech com www bavitech com ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 142 150 II D qa ES Maw V nmm ADE D 28 About PROCENTEC PROCENTEC is a specialist in PROFIBUS and PROFINET technology and develops products to optimize the production processes of end users Our innovative solutions ensure that our customers successfully operate in the world of industrial automation and enjoy maximum results from their process PROCENTEC globally supplies all the components required to install a measurable and steerable network We develop and produce all products in the Netherlands and they are exported through our worldwide distribution network At PROCENTEC we have a professional team of qualified support engineers who provide technical support on site and online Our professionals have more than 20 years of experience with PROFIBUS and PROFINET technology They provide the necessary support to end users during implementation procedures certification processes audits and malfunctions PROCENTE
27. Programs The Wizard window pops up with the following Wizards to choose from e Gather Network Info e Trouble Finder e Scan Inactive Network Please note that all previous data will be erased when the wizard is done Close The boxat the right of each Wizard button opens a window with a step by step explanation of each Wizard Also note the warning message in red If you run a Wizard this means that ALL previously recorded data will be lost 8 2 Wizard Gather Network Info Use this Wizard if you wish to make a full report of the currently connected PROFIBUS segment including a message trace and scope signal file The Wizard will automatically create a ZIP file with all files in a single file The Wizard will also generate a report in PDF format You do not need a ZIP program or PDF generator on your PC laptop this functionality is integrated in ProfiTrace 2 A bonus of using the Wizard feature is that all Reports will have been generated in the same way and with the same measurement lengths This ensures uniformity of the Reports The steps performed by this wizard are see next page ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 67 150 STEP 1 Clear all data same as File New in the menu STEP2 Initialize the ProfiCore Ultra if it is not initialized yet STEP3 Detect the baud rate STEP 4 Collect oscilloscope measurements of all stations STEP 5 Collect physical
28. System requirements In order to use ProfiTrace 2 and all sub programs your computer system should include the hardware and software listed below Minimum requirements e Microsoft Windows 7 8 XP or Vista e 600 MHz Intel Pentium III processor or equivalent e 256 MB of RAM e 100 MB of available disk space e 1024 x 768 resolution display e 1free USB 2 0 high speed interface port supplying 400 mA e 1Mouseor other pointing device Recommended differences to minimum e 1GHzlntel Pentium Ill processor or equivalent e 512 MB of RAM e 1280 x 1024 resolution display or better Attention Users of Windows 98 98 Second Edition and Millennium Me PROCENTEC is not able to offer software downloads or replacement USB sticks for Windows 98 98 Second Edition SE or Windows Millennium Me for ProfiTrace 2 Microsoft has stopped supporting these operating systems and this change involves all suppliers If you received a USB stick that lists any of these operating systems on the label be sure to keep it in a safe place since it will no longer be available from PROCENTEC NOTE The information in this document version supersedes any information in the digital or printed documentation Although the software for Windows 98 98 Second Edition and Windows Me will no longer be available it could be that ProfiTrace 2 works with these operating systems ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 11 150 1 7 Pr
29. USB interface Serie number To downiosd your 4 MI I licenene visit www procentec com licenses Fig 5 ProfiCore serial number The license file for the ProfiCore Ultra in Fig 5 is ProfiCoreUltra2_00050 PLD 4 3 Storage location of the license files The license file has to be copied automatically or manually to the APP directory of ProfiTrace 2 up to ProfiTrace v2 6 3 Starting from ProfiTrace v2 7 the license file is installed downloaded to a common application directory This means that when a future ProfiTrace version is installed the license does not need to be reinstalled copied to the Napp directory It also prevents problems with required administrative rights when using Windows Vista ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 28 150 For backward compatibility it is still allowed to place the license file in the Napp directory For new installations the mentioned common directory is preferred On Windows XP it is usually located at C Documents and Settings All Users Application Data procentec proficoreultra On Windows 7 it is usually located at C ProgramData procentec proficoreultra Note the common directory is usually a hidden directory so please adjust your file explorer to also show hidden files directories to be able to locate it manually It is allowed to store multiple licenses in the license directory of ProfiTrace It is also allowed to store
30. and or DSAP Destination Service Access Point The SAPs are located on the first 2 bytes of the data unit in the SD2 message Other message types do not carry SAPs PROFIBUS DP VO uses SSAP 62 and DSAP 54 to 62 Example 62 60 Get Diagnostics 62 61 Set Parameters Data Exchange messages do not use SAPs Send Data with Acknowledge Used with PROFIBUS FMS to send data to a device and receive a short acknowledgement as response NOT used by PROFIBUS DP and PA Send Data with No acknowledge This service is used when a broadcast is sent to a group of slaves multi cast or all slaves broadcast The slaves do NOT respond or acknowledge broadcast or multi cast messages A cable attached to a bus segment with a T connection Spurs are not recommended with PROFIBUS DP They are prohibited with 12 Mbps and PROFIsafe operations German term is Stichleitung Send and Receive Data It is used for SD2 messages to transfer data In normal DP VO exchange an SRD HIGH message is followed by a DL response from the slave See SAP See Spur line 134 150 Tap Connector A small cable to connect the ProfiCore to a PROFIBUS DP network It has been designed NOT to cause network disturbances due to spur lines A perfect vertical position for the ProfiCore is obtained that does not overpressure the piggy back plug which is attached to the DP network The cable is of the flexible type so you can move it to all directions Tbit See Bit Time T
31. and the Network Scan class 2 functions The Model Name is in some cases not properly defined by the product developer When a user has many GSD files in his catalog this product disappears in the list because of an unclear name Many PROFIBUS experts alter the Model Name of their GSD files to make them more readable and understandable This jeopardizes the certification of the device The available GSD file checkers can be a solution to verify the altered GSD file MIPI Multiple Protocol Interface Protocol defined by Siemens which uses the layer 1 and 2 of PROFIBUS FDL PA See PROFIBUS PA PCB Printed Circuit Board PI PROFIBUS International The International PROFIBUS Organization based in Karlsruhe PNO PROFIBUS Nutzer Organization The German PROFIBUS Organization based in Karlsruhe PROFIBUS DP Acronym for PROFIBUS for Decentralized Peripherals Specification of an open fieldbus system with the following characteristics Polling master slave system cyclic communications MSO Flying masters with robin round token passing coordination MM Connection based MS1 and connectionless MS2 MS3 acyclic communication between masters and slaves Options e g Data exchange broadcast DXB i e slave to slaves communication Isochronous mode of slaves Clock synchronization Redundancy PROFIBUS DP is standardized within IEC 61158 and IEC 61784 communication profile families 3 1 and 3 2 The term PROFIBUS DP also i
32. change Enabled 752 323 WAGO Rescue Input Unsianed8 byte Decimal 0 No change Enabled M E Es Input Unsianed15 Decimal 1088 No change Enabled 8 x Relais out 8 x Transmitter in Output Unsigned byte Decimal 59 Increase Enabled 8502 V2 0 MTL E Output Unsigned8 byte Decimal 64 64 No change Enabled 8642 ARTIS_CTM B 18DI DP B 16DI 16ED0 DP B 16DI1EDO DP B 16DI AC DP B 16D0 24 DP B 16D0 24 DP bu RARNOLAC np WAGO Kontakttechnik GmbH 750 333 WAGO Ident Number OxB 754 Bitmap buskopan Packeterrors 0 ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC Add the required input and output addresses From this point they can be directly manipulated and inspected Especially the automatic patterns are a very powerful feature 12 4 1 Data types The following input and output data types are possible that can be display as decimal hex or binary Data type Boolean Unsigned8 byte Range 1 or O 8 bit unsigned integer byte Range 0 255 Unsigned16 16 bit unsigned integer Range 0 65535 Unsigned32 32 bit unsigned integer Range 0 4294967295 Int8 8 bit signed integer Range 128 127 Int16 16 bit signed integer Range 32768 32767 Int32 32 bit signed integer Float IEEE754 Unsigned16 intel Unsigned32 intel Int16 intel Int32 intel Range 2147483648 2147483647 32 bit single precision floating point Range 1 5E45 3 4E38 As Unsigned16 but reversed
33. com 31 0 174 671800 31 0 174 671 801 info procentec com www procentec com 47 64 97 60 60 47 64 97 60 70 kai ade no www ade no 51 1637 3735 51 1528 0454 info controlware com pe www controlware com pe 48 32 230 75 16 48 32 230 75 17 intex intex com pl www intex com pl 40 365 809 305 40 365 809 305 sajgo tibor svt ro www svt ro 966 2 691 2741 966 2 682 8943 info asmestablishment com www asmestablishment com 65 62878063 sales allegro com sg www allegro com sg ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 140 150 SLOVAKIA ControlSystem s r o St rova 4 977 01 BREZNO Slovakia SOUTH AFRICA IDX ONLINE CC 1 Weaver Street Fourways Johannesburg South Africa 2191 SPAIN LOGITEK S A Ctra de Sant Cugat 63 Esc B Planta 18 Rub BARCELONA 08191 Spain SWEDEN P amp L Nordic AB Box 252 S 281 23 Hassleholm Sweden SWITZERLAND Berner Fachhochschule PROFIBUS Kompetenzzentrum Jicoweg 1 CH 3400 Burgdorf Switzerland TAIWAN Full Data Technology 6F No 200 Gangqian Rd Neihu District Taipei City 114 Taiwan TURKEY Emikon Otomasyon DES Sanayi sitesi 103 sokak B 7 blok No 16 Yukari Dudullu Umraniye Istanbul 34776 Turkey UNITED ARAB EMIRATES Synergy Controls 907 IT Plaza Silicon Oasis Dubail United Arab Emirates UNITED KINGDOM and N Ireland Verwer Training amp Consultancy 5 Barclay Road Poynton Sto
34. commissioning parameterization and demonstrations It fills the gaps that other products leave open and makes working with PROFIBUS a lot easier faster and more fun The main platform is a configuration environment in which the user can setup his slaves with the respective modules and parameters After setting up the master the user converts the slaves to Data Exchange without compilation or download ProfiCaptain is a master that sends information on the bus The user should be aware of the consequences in multi master networks when the baudrate and or busparameters are not set correctly 12 1 Setting up the DP Master A large part of the ProfiCaptain dialogs only work when the ProfiCore has been initialized in ProfiTrace Click the Init ProfiCore button After navigating to the ProfiCaptain tab see Fig 13 a configuration environment will appear to setup slave devices for Data Exchange and to perform a cyclical functions on available slave devices fig Profitrace for ProfiCore Ultra V2 4 c 2004 2009 PROCENTEC ProfiCore Ser Nr xxxxxOO002 E 81 x File Settings Help ProfiTrace ScopeWare Bar graph Topology Network Manager ProfiCaptain Load Project Save Project Zoom in Zoomout Draw Wire Setup Master Class 2 Commands DP V1 Class2 Watch Modify 1 0 UlICK GSD Master system configuration General i E Drives i Switching ded 120 eee k E Valves
35. count while DX Total retry count Times lost Address 36 IdentNo 0990 Manufacturer Woodhead Molex Model name ClassBI BO Bytes VO length 1 inputs 1 outputs Signal voltage Min 4 80 V Max 6 34 V Last 6 30 V Diag count while DX Total retry count Times lost Last oscilloscope image Fig 33 Oscilloscope measurements in the reports ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 6 Message and file recording To start a message recording select ProfiTrace and click on messages The button start message recording will start recording messages to memory see Fig 34 The message view shows the messages currently recorded The cursor can be used to navigate through the list The info panel will show information of the current selected message You can toggle between the non filtered and filtered view using the F6 button which also synchronizes the cursors if possible ES ProfiTrace 2 for ProfiCore Ultra V2 0 beta c 2004 2007 PROCENTEC 8 xj File Action Filter Trigger Toolbars View Report Settings Help ProfiTrace ScopeWare Bar graph Network Manager ProfiCaptain Load Data Save Data File viewer Setup record trigger Start message recording Stop message recording Set record fiter Set view T Init Praficore Ultra Close ProfiCore Ultra Auto detect baudrate Set baudrate je b 2 System activity Live list Message recording X Record to
36. couplers or any other media transitions you need to make new segments The electrical signals do not pass the repeater coupler the signals are re generated at the other side Creating a new segment is almost identical to making a new measuring point Right click on the first segment and choose Add Segment A new segment will appear under the first segment tree It also has a new measuring point Assign a name to the segment and measuring point Now you are ready to move your ProfiCore Ultra to the new segment and activate the correct measuring point First select the new Current segment in the drop down list and then select the new Current measuring point Do not forget the Stop Processing checkbox as described in paragraph 11 6 The result may look like the segment tree below ProfiTrace for ProfiCore Ultra V2 7 c 2004 2012 PROCENTEC ProfiCore Ser Nr 000 00013 File Action Filter Trigger Toolbars View Report Settings Help ProfiTrace ScopeWare Bar graph Topology Network Manager ProfiCaptain Reset Save Load Current Segment Properties Bargraph Scope Image Topology Mixer Floor 2 Y Current Measuring point After repeater Bi Show list M Auto add stations Stop Processing Ear Pre mixer Floor 1 EL Start of segment at master 3 f AJ 3 Master w E 6 Slave H H 12 Slave cD 28 Slave Est Mixer Floor 2 LJ 12 Slave LJ 28 Slave ProfiTrace
37. describes the used ASIC for example SPC3 LSPM2 ProfiTrace can display the Implementation type in the Live List when the GSD file of the device is available in the GSD directory and a Diagnostic telegram Ident Number of the device was detected on the bus LE LEr This byte specifies the length of a PROFIBUS message with variable data length SD2 frame It is counted from the DA byte to the end of the Data Unit The range is 4 to 249 LE is repeated in the LEr field for redundant data protection Live List The Live List is a matrix that lists all the available devices It is directly visible which devices are troublemakers With different background colours the status of the devices is displayed The Live List can also generate the product name of the devices when a diagnostic message is captured synchronized with the GSD library ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 132 150 MBP MBP stands for Manchester coding Bus Powered It is used to transmit bits on PROFIBUS PA Model Name This is a keyword in a GSD file that describes the name of a product and can be 32 characters wide The configuration tool of the master displays this keyword in the catalog ProfiTrace displays the Model Name in the Live List when the GSD file of the device is available in the GSD directory and a Diagnostic telegram Ident Number of the device was detected on the bus ProfiCaptain displays the Model Name in the catalog
38. devices 1 0 j C100 PB Slave 0940PSL001 i 16 x digital in Ex i 32 750 333 W 16 x digital out x 16 x digital out 1790P T8BV8B 253 1DP31 VIPA Green means Data Exchnage 505 500 6870 RBC 690E 1 0 Kuhnke z 750 301 V3 1 WAGO Confi gu red 750 333 WAGO 750 833 WAGO o 752 323 WAGO add fess 8 x 4 20m out 8 x Relais out 8 x Transmitter in 8502 V2 0 MTL 8642 ARTIS CTM B 16DI DP B BDIMEDO DP B lBDIMEDO DP B 16DI AC DP B 16D0 24 DP BABDO 2A DP R 1Enn AC NP Wagob754 gsd WAGO Kontakttechnik GmbH 750 333 WAGO OxB 754 buskopan Packeterrors 0 Double click on the device to check the status of the device Slave Setup Dialog x x More status info on these tabs Info amp Setup Diagnostics Capabilities Inputs amp Outputs Standard setting Address 32 IV Active v WatchDog Enabled Setup Modules amp Parameters Group Assignmen EE HEN DM EN ss IB Vendor Name WAGO Kontakttechnik GmbH Model Name 750 333 WAGO Ident Nr OxB 754 Hardware release H w 01 Software release Sw 01 Filename W agob 754 Green means Data Exchange Color coded state Color coded slave state e Additional feature Steal Slave Standard amp enhanced diagnostic and status information Master Lock Deactivated Parameter Fault reserved Invalid slave response Sync mode active F
39. did not detect a correct MBP end delimiter The MBP start and end delimiter are signatures used to identify the begin and end of a message on the MBP PA physical level and are additional to the start delimiter of the standard PROFIBUS message Can I change a device address with the PA Probe The PA Probe can only listen on a PA network So you cannot use it to change the address of your device If your network is using transparent couplers or links you can connect your ProfiCore to the DP side of your network and use ProfiCaptain to change the address ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 125 150 Product comparison With other tools that use PCMCIA and PCI cards the Live List stops when I select another function Is this better organized with ProfiTrace YES because of the ProfiTrace 2 structure everything keeps on running You can select multiple options and processes that run separately Is ProfiTrace 2 the same as the Profibus Tester PBT3 and other analyzers ProfiTrace 2 is much better it combines all the other clunky and expensive tools to just 1 simple USB interface You only have to do 1 investment to get everything and it can do a lot more Also you have integrated master functionality that the others cannot provide Message Recording Can ProfiTrace 2 decode DP V2 messages YES ProfiTrace decodes DXB SRD MCAST and Isochrone spare DP V2 related functions In networks that still have old
40. ecord trigger Start message recor Stop message ry lt Start file recording Live list e Messages S Messages with view filter app HSA 126 Reset selected station Info Panel data Diagnosi Stop file recording No data available Set record trigger Initial filename C Users PROCENTEC Desktop PROFIBUS log ptd File size limit 2047 MByte v V Enabled Max messages per file Enabled Max files Enabled Default only initial file To start the file recorder choose Action in the upper menu then choose Start file recording A dialog box appears in which you can set the record trigger initial filename file size limit maximum number of messages per file anda maximum number of files Each of these options can be enabled or disabled There are limits to the file size and quantity These are File size limit 2047 Mbyte Max messages per file is 100 000 000 Max files is 10 000 You can combine file options such as File size limit and Max files This will create an x number of files each with the configured file size limit A counter with 5 digits will be appended to the filenames with the format filename00001 ptd If you enabled multiple file recording you also have the option to stop recording if the maximum number of files has been reached Another option is to delete the oldest file where the recorder acts as a continuous logger To st
41. file X WENN Info Panel Livelst EJ Messages z Messages i ilter applied P Setup see pearch Search Dg tistics view Data inspec Framestructure SD1 message Source address 3 Destination address 6 Model Name JKTG6IDP ACHI umm EE RE pr Frametype Request message 38141 1o0 Data Exchange Req 1i 38142 p 2007 10 Data Exchange Res 1i PROFIBUS DP vO Message 38147 10 Data Exchange Req 2 Data Exchange z L 10 Data Exchange Res 10A i 3 Req 10 35 38 556 Sken pas token 10 35 38 556 SD2 3 gt 27 Exchange Req i 10 35 38 556 ACK Short acknowledge Res j10 35 38 556 SD1 3 76 Exchange Reg 111 10 35 38 557 Repeat SD1 3 76 Exchange Req 21 Nov 2007 10 35 38 557 Repeat SD1 3 76 Exchange Req 21 Nov 2007 10 35 38 557 Repeat SD1 3 gt 6 Exchange Req 21 Nov 2007 10 35 38 557 Repeat SD1 3 76 Exchange Reg 21 Nov 2007 10 35 38 558 Repeat lost SD1 3 76 Exchange Reg 21 Nov 2007 10 35 38 558 SD2 3 gt 43 Exchange Req 2 21 Nov 2007 10 35 38 558 SD2 3 43 Data Exchange Res z 21 Nov 2007 10 35 38 558 SD2 3 gt 10 Exchange Req LB 21 Nov 2007 10 35 38 558 SD2 3 lt 10 Exchange Res li 21 Nov 2007 10 35 38 559 SD2 3 gt 32 Exchange Req 2 21 Nov 2007 10 35 38 559 SD2 3 32 Exchange Res 38161 21 Nov 2007 10 35 38 559 SD1 3 gt 105 FDL Status Reg 38162 21 Nov 2007 10 35 38 559 SD4 3 gt 3 Token pass Pass token 38163 2
42. generate these Syncs messages anymore The Syncs should only be present for each DP slave or other Profibus protocol based station at the startup of a master or a re startup of a master after it has been shut down by a user When the master has not been voluntarily shut down or restarted and Syncs increase sporadically or continuously it could indicate disturbances on the network The combination of the Syncs and the 2 other Retries statistics can assist even more into solving problems that could be present on a network Retries total for this station This statistic is increased whenever ProfiTrace detects messages being re transmitted by a master A master will only re transmits messages if it expects an answer from it This is the case for SDA amp SRD message types This statistic holds the total amount of retries detected Retries worst sequence This statistic is maintained to determine the worst consecutive sequence of retries This is useful to determine if the retries are reaching or crossed the limit the master has setup in its busparameters max 8 retries according to the Profibus specifications Station lost This statistic shows the number of times a certain station master or slave has not responded to the maximum number of retries When a station is lost the master cannot control it anymore Slave station lost This statistic shows the number of times a certain slave has not responded to the maximum number of retri
43. gt Controllers HMI MMI Encoders NC RC Gatewg Setup DP busparameters BUE A Gatin Maai Current State Offline s KA E Ji 23 SL Jr B Ident Shee tte s Pc ur ou E Master mode selection Profib rr rin nla click nn tha E ee Fn LEES gt Select requested master states by pressing buttons below DP Master mode Mode description Master not active on the bus Sto Master only transmits tokens on the __ Stop bus and Profibus DP is not active c DP Master active but all outputs are Cea zero or set to fail safe state perate DP Master fully active 4 Slave Info Modules Close Packeterrors 0 Click on Setup Master followed by Set Autodetect Busparameters The dialog should indicate that the master is Offline no master activities ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 84 150 It is now possible to go 2 directions e 12 1 1 Setting the busparameters manually required when ProfiCaptain is the only master on the bus e 12 12 ProfiCaptain detects the busparameters automatically when it has to work in a multi master environment 12 1 1 Manual busparameter setting This paragraph describes the manual setting of the busparameters The simplest method is to select a baudrate and master address Please skip this paragraph for automatic busparame
44. indo Part v Messager Station statistics view Data inspection HSA 125 Reset selected station info Panel duin 057 Auoupdse into Panel Fresestrocture SD2 message m Mns B inn NN NN GN UK UN Source a res4 70 Model Kane 3785 SAMSON a Destination address 1 Ec a j Pe aram irameter Fiametype Response message Fault Ider t l to r rn PROFISUS DP VO Messag m id Cet Diagnostics Con R Number mis smatc h ag hs LER EI TE Master Add 1 s ident Nubes 3785 hex E 5 bytes Cortana 1 diagnostic block EI Device related 5 05 00 29 00 00 CI ox E No colour Device is A TER NT pm E os ones exo M Pup MAIN 43 js vo __ De ataE Exchange Configuration Fault p w n 1 J n tn wo SOPAIOLAO00 rogi M Es TEMP TMTO4 Liquphont MS AOC MEC geispaitEUZE AMS200LEUZE BPS34 LEUZE AGILIGATE 12008 8R0 FLSM120104 ILBKDISDO4 EI Apuceu 9923 ABO Enoet CUDA SEENE PHOENIX cen WAGO 750 833 Fig 17 Live List showing deviations The Live List also indicates Diagnostics of a slave with red blinking blocks in a slave box Upper left corner of cell blinking This station is active as a slave but also the Ext Diag bit is active This can indicate a critical problem on the attached I O measurement or control e g short circuit limit exceeded etc Upper right corner of cell i
45. influence the I O cycle time of the network Hub A Hub refreshes a signal and passes the information on to all nodes which are connected to the Hub Data frames which were received on one port are transferred to all the other ports chicken foot topology I amp M I amp M Identification and Maintenance Functions were created to help manage devices more easily They are based on Ident Numbers I amp M enabled devices internally manage a profile ID a device ID and a manufacturer and access www profibus com using an engineering tool to locate relevant files download them and save them locally The tables aid in the different life cycle phases of a product such as project planning commissioning parameter setting diagnostics repair firmware update asset management and audit trailing Ident Number The primary slave device identification is an Ident Number This is a unique 16 bits number assigned by the PNO It is stored within the device and defined in the corresponding GSD file In addition it is part of the GSD file name At runtime the Ident Number is used within the Set slave address procedure Parameterization telegram byte 5 6 Standard part of a diagnosis message byte 5 6 The Ident Number can be retrieved from a device Its main purpose is to make sure that a GSD file and configuration parameterization data between master class 1 and its slave are matching Implementation_type This is a keyword in a GSD file that
46. limitations of other available tools on the market The service team of PROCENTEC was frequently forced to invest heavily in interface cards and eventually could no longer accept the frustrations of PC locked licenses That the prices of the tools are relatively high and the displayed information is too complex was another contributing factor Therefore PROCENTEC decided to initiate the development of a tool that was ideally suited to our needs and those of the end user This outstanding tool that fits in your pocket will boost the capabilities of service maintenance and engineering technicians ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 1 2 Product features e Busmonitor for DP and PA with powerful statistics Repeats fall outs corrupted messages diagnostics cycle time etc e High speed digital oscilloscope SCopeWare Differential voltage A line B line noise overshoots reflections triggers e Bar graph Average Min and Max values of the bus signals per device e Topology Scan Automatic generation of the network topology e Reporting Automatic generation of detailed reports that are accepted by the industry e DP master ProfiCaptain A complete DP master has been integrated VO and V1 e ProfiCore Ultra USB interface Useable on PC platforms no power supply required and elimination of spur lines e OPC server and CommDTM e XP Vista and Windows 7 platforms e Multi language user interface
47. message SSAP The Source SAP of a message only SD2 and SD3 e Hex e Decimal DSAP The Destination SAP of a message only SD2 and SD3 e Hex e Decimal 6 1 1 Attention column The attention column displays abnormities that are detected in a specific message For all cases it means bad communication except bookmarks The following items are specified Attention SYNC Repeat FCS Error Wrong SD Wrong ED SD2 struct err SD2 rep err SD2 LE err Parity error Framing error MBP Start Del MBP End Del MBP frame err MBP CRC err Bookmark X Overrun error ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC Description A master is trying to contact a device for the first time In most cases after station lost or device unavailability The message is a repeat retry of the previous message The checksum of the message is incorrect The Start Delimiter is invalid The End Delimiter of the message is invalid The second SD byte in the SD2 message is invalid The second LE byte in the SD2 message does NOT match the first The LE byte of an SD2 message is invalid or out of range One or more bytes received in the message have parity errors Framing error Stop bit was NOT a logical 1 The PROFIBUS PA Start Delimiter is invalid The PROFIBUS PA End Delimiter is invalid The PROFIBUS PA formatting is invalid or incorrect e g invalid transition The PROFIBUS PA CRC is invalid Indicates a bookmark o
48. original master will then regain control again 12 4 Exchanging 1 0 data When the slaves devices are in the Data Exchange it is now possible to exchange data with the I O Select the specific slave device and click on module info at the bottom of the screen all the I O addresses should be visible Click on the Watch Modify 1 0 tab fi Profitrace for ProfiCore Ultra V2 4 c 2004 2009 PROCENTEC ProfiCore Ser Nr File Settings Help ProfiTrace ScopeWare Bar graph Topology Network Manager ProfiCaptain Load Project Save Project Zoom in Zoomout Draw Wire geo Lii Setup Master Class 2 Commands DP41 Class2 Watch Modify 1 0 GSD NetWork Sheet Watch I O dialog amp dd Insert Remove watch E Auto Change setting General Drives Switching devices 140 Te C100 PB hg Add Watch Memory Address 1 Mode No change X Update 0340PSL001 i Memory Type C Input F una 2 7 i 250 3 h x me in Exi ZA 33 150 333 Wi Insert Watch G Output Cycletime msec v Enabled x digital out ME Ce s Aral fi 16 x digital out DataType Unsigned byte Ar 1790P T8BVER Remove Selected 253 1DP31 VIPA enh ke Save Watch List Load Watch List Enable All Disable All unnke o fades vo Datavpe usan Coen Joe _ aulocharge Enable 750 833 WAGO Li Input Unsigned byte Decimal No
49. preinstall OK PRE INSTALLING NEW driver ProfiCoreUltra_power inf SUCCES driver C ProfiTrace_2_6_2_setup Install Drivers AProfiCoreUltra power inf preinstall OK Driver installation complete Finished OK Driver installation complete cem ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 16 150 3 5 ProfiTrace installation After the ProfiCore Ultra driver has been installed the setup procedure continues with the installation of ProfiTrace Welcome to the InstallAware Wizard for Profilrace V2 6 2 The InstallAware Wizard will install ProfiTrace V2 6 2 on your computer WARNING This program is protected by copyright law and international treaties To continue dick Next Click Next to proceed You have to accept the terms of the license agreement ProfiTrace V2 6 2 Install Please carefully read the following license agreement Profil race End User License Copynght c 2004 2012 PROCENTEC All Rights Reserved Usage of this software requires compliance with this license If you do not agree to the following terms please do not use or mstall this software 1 1 For the purpose of this Agreement Software shall mean the software identified above including but not limited to any updates modifications revisions copies and associated documentation provided by PROCENTEC and its licensors Click Next to proceed Pro
50. reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical photocopying recording or otherwise without the prior written permission of the publisher ProfiCore is a registered trademark of PROCENTEC Other products or company names are or may be registered trademarks and are the property of their respective companies ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC Important information Purpose of the Manual This user manual provides information how to work with ProfiTrace 2 Recycling and Disposal The parts of the ProfiCore Ultra can be recycled For further information about environment friendly recycling and the procedure for disposing of your old equipment please contact PROCENTEC Klopperman 16 2292 JD WATERINGEN The Netherlands Tel 31 0 174 671800 Fax 31 0 174 671801 Email info Qprocentec com Document Updates You can obtain constantly updated information on PROCENTEC products on the Internet at www procentec com You can also contact PROCENTEC Customer Support e by phone at 31 0 174 671800 e by fax at 31 0 174 671801 e by email at support procentec com ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC Contents Important information eessssssssee eee enne nennen nnn nenne nnn ener hse s esas n rennen sse ena n renean 3 1 Product description cssissaninnnarsinnnndieasiuadanrsanndnambrabbra
51. signals will reflect on the cable with an up down effect These reflections cause a rise in the average signal amplitude The width of the reflections can tell us the distance to the problem point When the distance is nearby the reflections are compressed in the bit Fig 38 shows an example of termination missing or wire break nearby Fig 24 shows an example of the Bar graph in this situation is x ES Profitrace for ProfiCore Ultra V2 5 c 2004 2010 PROCENTEC ProfiCore Ser Nr xxxxxx 00001 File Action Filter Trigger Toolbars View Report Settings Help ProfiTrace Scopeware Bar graph Topology Network Manager Mode B A Diff z B A Diff scale iv 7 Div A scale 1v Title ST 0 caes RE es aaa ee IN Time Cursors i Cursor 1 611 4 nSec Cursor 2 79 8 nSec Distance 633m requency Go H Bit Factor 0 80 Bits Volt Cursors Cursor 1 CursorDiff 425v 1 80 V T F 3 a c 5 en a T 2 o q a J 120 Fig 38 Termination missing or wire break When the distance is far the reflections end up in the adjacent bits This effect corrupts messages The user can make a conclusion if termination is missing or a wire break occurred by means of the installation drawings Make sure you know the last 2 devices on the segment and inspect both their signals By means of the reflections you can easily track the cable
52. slave This statistic shows the number of times a slave has correctly answered a Get Diagnostics message back to the master In general this must match the count of the Diagnostic msg req by master statistic Diagnostic msg res from slave when in DX This statistic shows the number of times a slave has correctly answered a Get Diagnostics message back to the master when it was already in Data Exchange This statistic can be used to determine the count of diagnostic signals from slave to master during normal operation ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 42 150 Last diagnostic msg size This statistic shows the size of the last detected diagnostics data of a station When a master is operational this diagnostic size should ideally not decrease in size since this imposes extra effort for a PLC programmer to first determine the size and only then evaluate the diagnostic data Largest diagnostic msg size This statistic shows the size of the largest detected diagnostic data of a station This is very important for checking that a DP slave never send more diagnostics than it has been configured for in the GSD used in the Profibus master configuration Exceeding the diagnostics size specified in the GSD can cause PLC s to crash or cause unreliable behavior Gj Profitrace for ProfiCore Ultra 2 2 1 c 2004 2008 PROCENTEC demowand1 ptd File Action Filter Trigger Toolbars View Report Settings Hel
53. the segment The Risk Margin is a number between 0 and 99 In a good stable segment with a Risk Margin of 90 for example there is much margin for electrical noise or reflection The closer the high and low voltages are to the middle O V line the less margin you have for disturbances on the network 0 Days 0 00 48 100 0 The margin is calculated based on the lowest signal level in the segment So if 8 stations have a Risk Margin of 90 and one station has a Risk Margin of 60 then the Risk Margin is 60 Fig 36 describes the method of calculation of the Risk Margin Segment 1 0 Days 0 00 13 72 2 EHES Measuring point 1 H D 4 Master H A 12 Slave w ED 22 Slave B 32 Slave GAB Diff voltage 6 4B Diff stable voltage Er Risk Margin c Ri Last 0 Days 0 00 05 27 8 Class C1DP Fig 36 Risk Margin calculation method The highest level of a 0 and the lowest level of a 1 are detected automatically for each individual station and the difference between that level and the O line is used for a calculation of the Risk Margin When the Risk Margin level drops below 60 the Traffic Light will switch to yellow and below 40 it will turn red 7 4 Network summary On the right of the traffic light is a list of important statistics These are the same as the statistics explained in paragraph 5 3 2 It is possible to reset each individual statistic For an explanation how to do
54. tool that permanently displays the latest captured data of selected variables in from the Data Exchange messages in a number of formats and views Add variabl to view Save and load the Data inspection Display the colour from the Live List Live ist E Messages E Messages wil Asi en Data inspel Add entry Edit entry Delete entry V Use liverist colorcoding Load inspect settings Save inspect settings i 5 Frameshuctue SD2 message Source address 1 Destination address 58 Model Name Excom M1 TURCK Frametype Request message PROFIBUS DP VO0 Message Data Exchange Real Selected devices 74 61 62 51 DX Response mputs DX Response nputs DX Response inputs DX Response inputs DX Request outputs DX Request outputs DX Response inputs DX Response inputs DX Response inputs DX Response inputs DX Response mputs DX Response inputs DX Request outputs DX Request outputs OX Request output 0 s wmo o oaooc So ce ooo AIAD ValeStatus PA V3 0 AIAD Val Status PA V3 0 ALAD ValeStatus PA V3 0 AIAD ValeStatus PA V3 0 Untigned8 Unsigned8 Unsigned8 Unsigned8 AIAD ValeStatus PA V3 0 AIAD ValeStatus PA V3 0 AIAD Val Status PA V3 0 ALAD ValeStatus PA V3 0 Unsigned16 Unsigned32 20 483285 Good NCJ 0k 0k Decimal Celcius 20 073067 Good NCJ 0k 0k Decimal Celcius 20 603806 GoodjNC OK 0k Decimal Celcius 1 015550 Good NC 0k 0k Bar b00000000
55. towards the problem The last 2 devices will also indicate the worst case reflections ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 9 3 Short circuit between A and B When there is a short circuit between the A and B line the reflection will step by step crash the signal to very low amplitude The width of the steps can tell us the distance to the problem point When the distance is nearby the reflections are compressed in the bit The short circuit also causes the idle line to be completely crashed Fig 39 shows an example of a short circuit between A and B ES ProfiTrace for ProfiCore Ultra v2 5 c 2004 2010 PROCENTEC ProfiCore Ser Nr xxxxxx 00001 81 xj File Action Filter Trigger Toolbars View Report Settings Help ProfiTrace Scopeware Bar graph Topology Network Manager Mode B A Diff z B A Diff scale iv 7 Div x A scale 1 619 6 nSec 88 0 nSec Cursor 2 nn TOT NEN N NEN INNEN Pe ee DNI sc ER uit CNN j 1 x L T Vv 4 8 1 Lb 1j M D p EH H1 734 i ID 0840 Cycle through devices SSS EE ETES 20 ETS _60 _80 99 100 120 oll a Fig 39 Short circuit between the A and B line When the distance is far the reflections end up in the adjacent bits but the signal amplitude does not crash comple
56. voltages to go too low inside the 1 and O bit making the value lower than usual For both modes only the range between 20 and 80 96 of the bit time is considered so that normal rise and fall times do influence the results If a value becomes lower than 2 5 V the specific bar will become red instead of green 5 7 Topology scan ProfiTrace has the capability to generate the topology of the PROFIBUS network without shutting down the installation The Topology scan creates a clear network drawing that contains the location of the devices and length of the cable that links them see Fig 28 M ProfiTrace for ProfiCore Ultra V2 1 c 2004 2008 PROCENTEC ProfiCore Ser Nr xxxxx00002 E 81 x File Action Filter Trigger Toolbars View Report Settings Help ProfiTrace ScopeW are Bar Length between devices Total cable length Fig 28 Topology scan 5 7 1 Restrictions for using the topology scan e Topology detection only works on 500 kbps and 1 5 Mbps e ProfiCore Ultra must be connected to the beginning or the end of the segment e You must know on which station address the ProfiCore Ultra is connected e Distances lt 2 m or gt 230 m relative to the measurement point cannot be measured reliably ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 51 150 e Thesegment must be without disturbances spurs noise incorrect termination etc e The segments network must be install
57. x H mm with DB9 Weight Ambient conditions Operating temperature Storage temperature Isolation class Power supply specifications USB current consumption without adapter Adapter Voltage Adapter current consumption Connector descriptions DB9 female PROFIBUS Expansion connector Power connector ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 108 x 68 x 28 mm Approximately 125 g O to 60 Celsius 20 to 70 Celsius IP 20 DIN 40 050 400 mA 9 V 500 mA Pin 3 B line Pin 8 A line Pin 6 VP Pin 5 DGND Case Ground Shield Pin 1 3 3 V output power Pin 4 Trigger GND Pin 5 Trigger Pin 8 Power GND Opening 6 0 mm Center pin 1 95 mm Plug according to NES J 21 NES J 21 W NES J 210 XNES J 210 117 150 Technical data ProfiCore Ultra Frequency 2 x 192 MHz A line and B line 384 MHz Differential measurement Bandwidth 100 MHz Voltage Differential 9 to 49 V Single ended 4 5 to 48 5 V with the PA Probe ultra these values are different ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 118 150 18 Technical data PA Probe Ultra Technical data PA Probe Ultra Dimensions L x W x H mm 76 x 33x12 mm Weight Approximately 25 g Operating temperature O to 70 Celsius Isolation class IP 20 DIN 40 050 PROFIBUS PA Connector Pin 1 Shield Pin 2 PA Pin 3 PA Voltage DC 0 33 V AC 1 2 Vtt Inpu
58. 0 Warnings 0 Rev 2 fRedscan GSDs Click Close to finish the GSD scanning 3 10 Installing GSD files in ProfiCaptain The catalog update of the GSD files in ProfiCaptain is NOT automatically linked with ProfiTrace The scanning of GSD files has to be repeated in ProfiCaptain bu ProfiTrace for ProfiCore Ultra V2 1 c 2004 2008 PROCENTEC SITRANS FM SITRANS P SITRANS T SIEMENS SRDS60 TMT184 E H TP303 Transmitter 1 Al PhyL 0 Transmitter 1 Al Phyl 1 Transmitter AF800 Transmitter TF211 TRIOWIRL _4000 5_400f T1303 SMAR UFC 3Beam VEGAPULS 40 50 V2 0 VK 535 GMC AG YPOIFC300 MBF Rev 2 F Click Settings followed by Generate Catalog to scan the GSD files To remove a GSD file from the catalog you need to manually delete the file from the GSD directory and generate the catalog again Settings Generate Catalog ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 25 150 3 11 Setting colour preferences The colours of the ScopeWare signals and background can easily be adjusted in the Settings Preferences menu D Profitrace for ProfiCore Ultra V2 1 c 2004 2008 PROCENTEC gt 2181 x File Action Fiter Trigger Toobars View Report Settings Help Profil race Scopeware Bar graph Topology Netwo LosiDats Save Data File viewer Init ProfiCore Ultra System activi Live st D Messagerecordng gt lt Recordtotie gt
59. 02 580 39 010 65 63 233 procentec gfcc it www gfcc it ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 139 150 JAPAN TJ Group C O Japanese PROFIBUS Organisation West World Building 4F 3 1 6 Higashi Gotanda Shinagawa ku Tokyo 141 0022 Japan KOREA Hi PRO Tech Co Ltd 2802 U Tower 1029 Youngduk dong Giheung gu Yongin Si Kyunggi do 446 908 Korea LEBANON Industrial Technologies S A L ITEC Point Center Boulevard Fouad Chehab Sin El Fil Beirut Lebanon MEXICO Grid Connect Inc NETHERLANDS PROCENTEC B V Klopperman 16 2292 JD Wateringen Netherlands NORWAY AD Elektronikk AS Boks 641 N 1401 SKI Norway PERU ControlWare Jr Los Silicios 5409 Los Olivos L39 Peru POLAND INTEX Sp z o o ul Portowa 4 44 102 Gliwice Poland ROMANIA S C SVT Electronics S R L Br ila 7 540331 Tg Mure Romania SAUDI ARABIA ASM Process Automation Al Zahra Dist Attas st cross section with helmy Kutby St Villa no 25 Jeddah 21553 Saudi Arabia SINGAPORE SOUTH EAST ASIA Allegro Electronics 236 Serangoon Avenue 3 07 98 Singapore 550236 ono comm mm mm Topy Tmp 7m mo m 81 3 6450 3739 81 3 6450 3739 info profibus jp 82 82 31 216 2640 82 82 31 216 2644 chays hiprotech co kr www profibus co kr 961 1 491161 961 1 491162 sales iteclb com www iteclb com 1 530 219 2565 Spanish tomf gridconnect com www gridconnect
60. 1 DataTransport Req has failed A reason code and classification is also returned to determine the problem The master maintaining the class 2 acyclical connection indicates that there are no pending Read Write or DataTransport commands but the connection should remain open The class 2 connection remains open Request the readiness of a pending Read Write or DataTransport request Broadcasting Data Exchange data of a slave publisher to other slaves subscribers without having to go through the master first It is also called Slave to Slave communication Special FDL status request frame which is used for DP V2 Isochrone mode Its function is to produce bus activity in the spare time of an isochrone cycle to avoid a time out and to keep the cycle time constant 6 2 File recording If you want to log PROFIBUS messages over a longer period for example to store process data you can use the File Recording option File Recording generates files with PROFIBUS messages The size and quantity of these files can be adjusted ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 63 150 lt Filter Trigger Toolbars View Report Settings Help Init ProfiCo DLE m Topology Network Manager ProfiCaptain Select Action Start File recording Start message recording Stop mess Je Autodetec baudrate Set baudrate 1 5Mbps recording gt lt Record to file X Close ProfiCore
61. 1 Nov 2007 10 35 38 559 SD2 3 27 Data Exchange Req 38164 21 Nov 2007 10 35 38 559 ACK 38165 21 Nov 2007 10 35 38 559 SD2 3 gt 43 38166 21 Nov 2007 10 35 38 559 SD2 3 lt 43 Short acknowledge Res Data Exchange Req Data Exchange Res Y NND 4 Plugin output Activity log Message data Fig 34 Message recording On the bottom a blue progress bar is shown to indicate how full the message buffer is When the progress bar fills the whole width the message buffer is full If required the message buffer size can be increased in the general preferences By default 1 000 000 messages can be recorded with the message recording utility If more are required use the file recording utility Access this feature by choosing Action Start file recording in the main menu ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 6 1 Message columns The selection and order of the message columns headers can be customized by the user Fig 35 illustrates an example of some displayed columns in the message recording BEL eD Dec 5726 U0 Dec BEN eg Dec TZS el Dec 57239 0 Dec Data Exchange SRD HIGH Data Exchange a BE pata Exchange Res SRD HIGH Data Exchange Bec be Exchange Bes SED HIGH Data Exchange Bec SRD HIGH Data Exchange Bec EE Dat Exchange Bes SED HIGH Data Exchange Bec Dh pata Exchange Rez SRD HIGH Get Liacmostics Beg SDZ 1 54 BRO Get D
62. 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 9 5 Too many terminators Too many terminators show a middle way between a good signal and a short circuit between A amp B The signals face a low impedance but mostly stable enough to keep on running The reflection only consists of a small bump The width of the reflection can tell us the distance to the unwanted termination The additional termination also causes the idle line to have a lower voltage Fig 42 shows an example of too many termination 24 ProfiTrace for ProfiCore Ultra V2 5 c 2004 2010 PROCENTEC ProfiCore Ser Nr xxxHHHOOOOI File Time Cursors Cursor 1 619 6 nSec Cursor 2 438 5 nSec orl i 49 nS e Distance 26m ap requency B2eJHz Bit Factor 027 Bits Volt Cursors E Cursor 1 1 83 V Cusor2 206v CursorDiff 3 89 V SOS RRA EI Eb D CRM SERE POSER J l 1 MEN Persa sms ae mom eh DRE NEM ns 70 30 92 3E 37 E 100 101 102 103 104 105 106 107 108 109 111 112 113 114 115 116 117 118 121 122 123 124 125 126 Fig 42 Too many termination ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 9 6 Notpowered termination Not powered termination will show a small deviation in the signal and is difficult to diag
63. 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 81 150 11 8 Rearranging segments If you have created multiple segments you will have noticed that all stations appear in all segments The Network Manager cannot detect automatically which station is located in which segment You can delete stations manually from the segments in which they do not belong The following explanation will use this example network layout The repeater in the middle has no address however it does generate signals on the bus So it should be included in the Report The solution is to make one station at the other side of the repeater an alias representing the repeater m ProfiTrace for ProfiCore Ultra V2 7 c 2004 2012 PROCENTEC ProfiCore Ser Mr 2000000013 Ele Action Filter Trigger Toolbars View Report Settings Help ProfiTrace Scopeware Bar graph Topology Network Manager ProfiCaptain Reset Save Load Current Segment Properties Bargraph Scope Image Topology Miser Floor 2 Current Measuring point a ARE ale Cd After repeater aue Titlename Repeater B1 Show list Address 12 M Auto add stations Address iz alias Stop Processing Device Type Standard Repeater Eat Pre mixer Floor 1 Primary E Start of segment at master 3 E EHE 3 Master E 6 Slave H 1 2 Slave mE 28 Slave 4E Mixer Floor 2 EM After repeater 3 Master b Slave 12 Slave 28 Slave Dele
64. 4 4 Obtaining the license files There are 2 ways to obtain the license files see Fig 7 1 You can download the license file through our website www procentec com licenses Fill in your data and serial number of the ProfiCore Ultra See paragraph 4 2 where to find the serial number Automatically a web page will open where you can directly download the license After download you have to copy it to the correct directory see paragraph 4 3 for the storage location 2 If your PC has internet connection you can download the license automatically through ProfiTrace Connect the ProfiCore Ultra to the USB port and click on Init ProfiCore ProfiTrace will inform you that it could NOT find valid license files and an option will be offered to download the license automatically ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC ge License Server www procentec com licenses Wr Internet License File License File L It is allowed to copy the license Iti on multiple PCs Possible Users ProfiCore Fig 6 License files on multiple PCs E License er Internet e re or atm Automatic license download from Profitra Ta www procentec com licenses Possible Users ProfiCore Fig 7 Obtaining the license files ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 30 150 4 5 Requesting a Trial License If
65. 5 PROCENTEC 1 Product description 1 1 Introduction ProfiTrace 2 is the most powerful mobile analyzer for PROFIBUS networks It is the latest generation in the line of busmonitor technology Thousands of users T rrr benefit daily from this great tool ProfiTrace combines IR GIEGRE all required tools in one ULIRA e Busmonitor e Oscilloscope e Bar Graph e Topology Scan e Reporting e DP Master Technicians can check and troubleshoot the complete PROFIBUS network with 1 software package and 1 piece of hardware An enormous reduction in equipment weight costs and required knowledge The advanced USB hardware ProfiCore Ultra is internally equipped with a high speed digital oscilloscope and able to capture bus signals running at 12 Mbps It can also be used on PROFIBUS PA installations with the PA Probe Ultra ProfiTrace is an essential tool for maintenance commissioning and troubleshooting as well as product development Typical failures such as noise reflections voltage drops termination problems double addresses wire breaks and configuration faults are easily identified Random errors such as overshoots error telegrams repeats and diagnostics can also be captured and logged The results can be exported to detailed reports which are accepted by the industry Predictive maintenance and asset management are really possible with ProfiTrace This revolutionary tool has been developed because of technological
66. 50 After the selection ProfiTrace will exit and you have to restart it After the restart the user interface has switched to the preferred language 3 9 Installing GSD files in ProfiTrace ProfiTrace has the capability to display the Model Name of the device in the Live List The Model Name comes from the GSD file of the device If you want to use this feature you have to copy all the required GSD files to the GSD directory You can also point to a GSD directory of another application in the setting menu After the copy process ProfiTrace has to scan the GSD files in order to create an internal catalogue You only have to do this once Unless you remove add or edit a GSD file Ga Profitrace for ProfiCore Ultra 2 0 2 c 2004 2008 PROCENTEC ProfiCore Ser Nr 00000057 File Action Fiter Trigger Toobars View Report Bec Help ProliTrace ScopeWare Bar graph Network Manager Preferences Plugins hooves lhe Close ProfiCore Ultra Auto detec Click Settings followed by Scan GSD Library to proceed GSD library scan dialog Click Re Scan GSDs to proceed ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 24 150 GSD library scan dialog Filename C Program FilesProfiTrace V2 0 2 app gsdBARA2305 G5D results Errors 0 Warnings 5 Rev 1 Filename C Program Files ProfiTrace_ 2 0 2 app gsd BUERB522 G5D results Errors 0 warnings 6 Rev 1 Filename C
67. 9 Slave The Network Manager is explained in full in chapter 11 5 9 ProfiCaptain Test and control your devices ProfiCaptain is a PROFIBUS DP class 1 and 2 master that has been designed for applications like I O tests commissioning parameterization and demonstrations It fills the gaps that other products leave open and makes working with PROFIBUS a lot easier faster and more fun The main platform is a configuration environment in which the user can setup his slaves with the respective modules and parameters See Fig 29 After setting up the master the user converts the slaves to Data Exchange without compilation or download See chapter 12 for details D ProfiCaptain is a master that sends information on the bus The user should be aware of the consequences in multi master networks when the baudrate and or busparameters are not set correctly ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 52 150 bg ProfiTrace II for ProfiCor SIPART PS2 SIEMENS SITRANS F SITRANS FM SITRANS P SIEMENS SITRANS T SIEMENS Stellungsregler TZID F Stratos 222n X Series i Temperatur Messumformer T TF12 ABB TMT184 E4H Transmitter 1 Al PhyL 0 Transmitter 1 Al PhyL 1 Transmitter AF800 Transmitter TF211 TRIOWIRL V 4000 5 400 TT303 SMAR L iom m GSD Filename EH3 1503 GSD Vendor Name Endress Hauser Model Name Deltapilot 5 2nd Generation
68. A La Chataigneraie 37510 BALLAN MIRE France GERMANY PROCENTEC GmbH Benzstrasse 15 D 76185 Karlsruhe Germany INDIA UL Engineering Services amp Software Pvt Ltd Nirman Classic Katraj Kondhwa Road Katraj Pune 411046 India IRELAND PROFIBUS Ireland Automation Research Centre University of Limerick National Technology Park Plassey Limerick lreland ISRAEL Instrumetrics Industrial Control 8 Hamlacha St New Industrial Zone Netanya 42170 Israel ITALY C S M T Gestione S C A R L Via Branze n 43 45 25123 Brescia Italy Genoa FIELDBUS Competence Centre Srl Via Greto di Cornigliano 6R 38 16152 Genova Italy cw mon muni non se TIT xd ur one quo uc Ion ns d ens 2 02 2524 2842 2 02 2524 2843 aya elshafei masautomation com www masautomation com 372 605 2526 372 605 2524 info saksa automaatika ee www saksa automaatika ee 358 40 8222 014 info hantekno com www hantekno fi 33 247 76 10 20 33 247 3795 54 jy bois agilicom fr www agilicom fr 49 0 721 831 663 0 49 0 721 831 663 29 info procentec de www procentec de 91 202 696 0050 91 202 696 2079 dileep miskin ulepl com www ulepl com 353 61 202107 or 35361240240 353 61 202582 info profibus ie www profibus ie 972 9 8357090 972 9 8350619 info instrumetrics ic co il www inst ic co il 39 030 6595111 39 030 6595000 profibus csmt it www csmt it profibus profinet 39 010 86
69. B port of your laptop or PC ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 103 150 14 2 Setting up the PCD server Start the PCD PROCENTEC Communication Driver server located in Program Files PROCENTEC PCD You should see the PCD logo in the system tray Right click the PCD icon then choose Show Click Modify enter a name for the interface choose the latest ProfiTrace ProfiCaptain driver enter the serial number of your ProfiCore Ultra and click OK Note If you have only a 77 6 one ProfiCore Ultra connected to your system you can leave the serial number field empty 14 19 3 5 2012 Interface Settings Interface Name Location 1 Profit race ProfiCaptain V2 6 2 0000 00029 Leave empty if serial nr is irrelevant Fig 54 Setting up the PCD server 14 3 Using the CommDTM Start your FDT manager and create or load a project Vendor independent platform PACTware is used in the example below Refer to the manual of your FDT manager for details In the upper menu choose Device Add device and click on PROCENTEC DP V1 Master as shown in Fig 55 ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 104 150 C8 All Devices All Devices PRE Driver et 3 Meat REM PROCENTEC DP V1 Masi Profibus DPV1 PROCENTEC FDT 1 0 5 0 201 Be D river Gro Type Prot Show unselected devices too 4 TT PROCENTEC D
70. Bar graph Topology Net screen Mode BA Diff B A Diff scale 1V Div Address 36 v Trigger Message v Trigger Start of response Reset trigger delay l x Cursors active Measurement Mode Double click onthe devices for triggering Fig 21 ScopeWare ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 47 150 Ed ProfiTrace II for ProfiCore Ultra c 2004 2007 PROCENTEC E l x Fie Action Filter Trigger Toolbars View Settings Help ProfiTrace ScopeWare Bar graph Network Manager ProfiCaptain Mode B A Diff JE B A Diff scale 1v Div T A Diffscale 1V Dis JH Time scale 1 uSec 4 M SD1 M SD2 E SD4 M Short Ack Address 27 Trigger Message j gt Trigger Start of response Iv Freeze Cursors active Bit interpretation Detected glitch in the signalling Fig 22 Bit interpretation 5 6 Bar graph The Bar graph illustrates the average signal strength from all available devices see Fig 23 It is a helpful utility to get an impression of the overall signal quality of the network i Profitrace for ProfiCore Ultra V2 1 c 2004 2008 PROCENTEC ProfiCore Ser Nr xxxxx00002 E l8 xi File Action Filter Trigger Toolbars View Report Settings Help Giegesbociutsabessaarseenpiil Measurement options Average message 6 33 amplitude 541 531 531 52 a 6 Device ad
71. C also is the international accredited Competence and Training center for PROFIBUS and PROFINET We provide training courses that help employees using those techniques optimally for their business objectives Products ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC ProfiTrace ComBricks ProfiHub PROFINET tools Cables and connectors Training courses e PROFIBUS training courses e PROFINET training courses e Product training courses Services Competence center Support amp Consultancy Network certification amp Audits Testlab amp Democenter 143 150 29 Certificates QualityMasters etu ISO Certificering QualityMasters hereby declares that D Procentec B V Wateringen has a management system that meets the requirements of the standard NEN EN ISO 9001 2008 for the scope Providing training courses technical support product development and the exploitation of the test laboratory Date of original approval 10 02 2003 Date of issue 10 04 2013 Valid until 10 02 2016 Certificate number NL 6313uk On behalf of Stichting QualityMasters gtit us 7 ust i Feurths i Er aa N B The falluse to meet the conditions as set forth in the certification agreement or aoo compliance with I the given standant and or guidebnes may bead to rhe Suspension or Cancellation of the certifi ate This cestificate remains the property of Stichting QualityMasters Niewwl
72. E RPE OP CENSET IUE KE 65 Tos c MITES 66 Tale NEWWOrK SUNN ROO Omm 66 8 E a EEEE E OEN E E A A E AEE A AE A A E EE ES 67 8 1 Accessing tbe Wizard features esu idee iom aa EUR E Fors EFE adv een eee ea be 67 8 2 Wizard Gather Network Info ccccccsssssccccceeseccecceesscceceeeueccesseaeeeeeseeusecessuaeeeeesaaaeeesseaaeeesseees 67 8 3 Wizard Scan Inactive Network cccccssssscccccssssecccceesececseeecceeseeseceeeseeuseeesseeseeeessaaeseessaaneeeessages 68 es Oscilloscope measurements RS 485 DP en nennen 69 9 1 ACCEDER ne ae bu tius cede cuseaendat 69 9 2 Termination missing or wire break sisi 70 9 9 Short circuit between A and Be css date essence ete ees 71 9 4 Short circuit between B and Shield ss 72 Boc LOO Way TOLLERE wasabi eque ee esu Ua idR cede ud n esa de on NE 73 9 6 Not powered terMinatiOn ccccccsseccccssscccesseccceeccccsnecessenecessueceeseuseeesaeceseueesseaecessaeeeessaesessaasss 74 OEM OEM a a 75 10 Oscilloscope measurements MBP PA cccccccesscecsssssececceceeeeseccseeseeuseeceessssecceeeeses 76 10 15 ACC SD ODA uU mar RO Ce eee A ee ee IUD ene ee 76 11 Network Manager ccccccccccccccccccccseeeeececceesseeuueeeeeeceeseesuueeeseeeceeeeseuuaesseeeeeeseesuaeeeeeeeeeeeeeanaees 17 IEI el dre pde petii a eee ee tes ee 77 IL2 View Bal GAIDA 2 LU ve prevede sur E E et DR RES TEUER rte Dea DU MEUS SIN M TOP UE 78 11 3 View individual scope signals cccc
73. FMS components will I be able to see the SAPs and hex data from messages of these components YES ProfiTrace will capture and display every PROFIBUS message So you can inspect the SAPs and the data Also the Live List and large parts of the statistics are useable Bar graph What is the difference between AB Diff voltage and AB Diff stable voltage AB Diff voltage is the average amplitude of the signal and AB Diff stable voltage is the minimum measured amplitude ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 126 150 22 Products and spare parts Component ProfiTrace 2 Troubleshooting Toolkit Ultra Plus Troubleshooting Toolkit Ultra Pro Tap Connector Tap Connector DB9 M12 Topology scan license OPC server license Order code 30021 37021 38022 13020 101 00052B 26010 101 00231B Remarks e ProfiCore Ultra e USB cable e ProfiTrace 2 no oscilloscope bar graph and topology scan function can be upgraded later e ProfiCore Ultra e USB cable e ProfiTrace 2 e ScopeWare e Bar graph e Topology Scan e Reporting e Tap Connector e Blue carrying case e ProfiCore Ultra e USB cable e ProfiTrace 2 e ScopeWare e Bar graph e Topology Scan e Reporting e Tap Connector e Blue carrying case e OPC server e PA Probe Ultra e ProfiCaptain Already included in the Toolkit Ultra Plus PRO License for existing customers already includ
74. IL JWE ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 146 150 30 Notes ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 147 150 ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 148 150 ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 149 150 PROCENTEC BV Klopperman 16 2292 JD Wateringen The Netherlands T 31 0 174 671 800 F 31 0 174 671 801 E support procentec com W www procentec com
75. Places RE Desktop SS Libraries k 1 item Fig 8 Example of changed license file name STEP2 Make sure your computer is connected to the Internet required STEP3 Start ProfiTrace and initialize the ProfiCore Ultra STEP 4 A window pops up saying that you have no license Now click on Get trial activation License info amp license utility dialog E3 Please select one of the buttons on the right for possible actions Download amp install license Last read ProfiCore serial number lt lt 400013 TT License related actions are related to this ProfiCore Serial number Go to PROCENTEC website Bequest tial licence SSS EEE Get trial activation OO nstall license tile Show list of installed licenses Internet connection required The software will start with the trial license If nothing happens your corporate firewall might block the outgoing connection In that case contact your network administrator It is also possible that the trial period has ended After the trial period simply change back the file name of the original license and continue working with it ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 32 150 C PS P K S1 at L 4 AS IN IL C A LL lA no D FM f orn l JI1 Am E T P 5 1 Attaching ProfiCore Ultra to the installation Attach the ProfiCore with the USB cable to your laptop PC The green LED
76. ProfiTrace when this assignment is ready ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 106 150 ASSIGNMENT 2 DRAWING OF THE INSTALLATION E Create a technical drawing of the PROFIBUS installation finish it within 15 minutes Instructions e Indicate clearly the location of the devices with its name and if it is a master or slave e indicate the network addresses by looking at the dip switches or rotary switches e Indicate how the cable is going in and out the connectors e Indicate the location of the termination e Do NOT remove cable tray covers or open connectors ASSIGNMENT 3 ASSESSMENT OF THE CONNECTED DEVICES e Start and initialize ProfiTrace e What is the detected baudrate _ e How many masters and or slave devices does this installation have e What is the value of the HSA e Does the Live List correspond with your drawing e Switch the PLC master OFF ON Wait until the complete installation has restarted e Does the Live List correspond with your drawing _ e Adjust the detected differences in your drawing ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 107 150 15 2 ProfiTrace Live List ASSIGNMENT 1 INTERPRETATION OF THE LIVE LIST COLORS Fix each fault after a specific step Switch a slave OFF or remove the bus connector and investigate the Live List Change the network address of a slave and investigate the Live List don t forget to sw
77. SB port sise 20 205 De OE a A a ee A AUR COUR CURRE 22 3 8 Selecting the language of the user interface 23 3 9 Installing GSD files in PEOR RAR a atn GIN aa de oo de 24 3 10 Installing GSD files in ProfiCaptain iii 25 311 Setting colour Die Ecc EODD 26 LA RSS a ee ae ee ee 27 4 dt 28 MN O CO eera Os 28 4 2 Characteristics of the license file NaMe aa nca nantes da ac dt 28 4 3 Storage location of the license files sisi 28 44 eia SERIA e DS NI RTT 29 4 5 Requesting a Trial ICS scene pU Stat NO KEKEE ENKEN EOI pesar E eus te dures 31 4 6 Activating a Trial License cccseussescsvsscncususcncusrescavssencueusevensrencacasencususevassrencusaseneuerescassrencucsces 31 B BITTE Ec AEE DEUM RETE PE 33 5 1 Attaching ProfiCore Ultra to the installation ss 33 5 1 1 Attach the Tap Connector to the ProfiCore DP is 33 5 1 2 Attaching the ProfiCore to the DP installation ss 34 5 1 3 Attaching the PA Probe to the ProfiCore ccccccssssecccccesseccccceseecccsousececcseusececsseuseeeessasereeseass 35 5 1 4 Attaching the PA Probe to the PA installation ss 36 Ead PT OA mmm 37 zT BusmontorAnNaly2E PEE m 39 SPAM MEE Anc mr a ana de tie 40 D SEAL SUNG ee ee E ne AT 5 3 3 Message recording sacs sncacrssssnnacasesstens esse cesse coop cac MEET INI E I F memes sesnors cc dessertes series 44 D WE NI cereo RE m UU
78. a ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 12 3 Configuring slave devices The first thing that should be done before configuring slave devices is to update the catalog see 3 10 When the catalog is up to date with the required GSD files the configuration procedure can start If the slave you wish to add is not in the GSD list use the menu Settings Add Copy GSD to catalog to include the slave in ProfiCaptain 12 3 1 Filtering GSDs If you have inserted many GSD files and you wish to sort or search them use the Filter by checking the Filter GSDs checkbox You can filter by e Ident number enter the 4 digit HEX number in the Filter text box e Model Name enter the model name in the Filter text box e Vendor Name enter the vendor name number in the Filter text box e Found in Live List shows only GSDs with Ident numbers matching the current Live List e Last Network Scan shows only GSDs with Ident numbers matching the last Network Scan 12 3 2 Adding devices You can easily drag a GSD file from the catalog to the bus It is not required to connect the slave device with the virtual bus The device can also float somewhere in the configuration screen To make it visually more attractive the user can increase the length of the virtual bus by ticking draw wire When a slave device has to be deleted just right mouse click on the slave device and select delete ProfiTrace for Prof
79. and Parc 157 3351 L Papenidrecht ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 144 150 PROFIBUS PROFINET Certificate for a Pl Competence Center PI confirms that PROCENTEC Dennis van Booma Turfschipper 41 2292 JC Wateringen THE NETHERLANDS is a fully accredited Pl Competence Center for PROFIBUS basic PROFIBUS PA This certificate is granted according to the Quality of Services Agreement for P Competence Centers and is valid until December 31 2013 CEA Official in Charge Chairmen of PI Ma J rg Freitag Chairman d L3 Lo L3 DU JWE ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 145 150 PROFIBUS PROFINET Certificate Authorization as PI Test Laboratory for PROFIBUS PROFIBUS Nutzerorganisation e V accepts PROCENTEC Turfschipper 41 2292 JC Wateringen The Netherlands as authorized PI Test Laboratory for PROFIBUS Slave Devices PA Profile Devices The authorization is based on the assessment dated March 20 2013 and the related assessment report The execution of the tests aimed in the PROFIBUS certification shall be conform to the PROFIBUS Standard and the valid guidelines Jar DILUTED ARS I Ul LGLGHF Uu o Ie IGi Iz Ga al a adl o uz This authorization is valid until December 31 2014 Official in Charge Board of PROFIBUS Nutzerorganisation e V K K P us L9 Ld
80. apture bus signals running at 12 Mbps see Fig 2 It can also be used on PROFIBUS PA installations with the PA Probe Ultra The RS 485 driver is 1 5th of a standard PROFIBUS busload The chance of disturbing a working installation is therefore reduced to a minimum ProfiCore Ultra has the capability to cache data in its on board memory in case of windows performance problems or higher priority tasks like the hard disk ProfiCore Ultra will NOT lose a single message Fig 2 Internal structure of the ProfiCore Ultra Isolated USB Support HS 485 DP Technology OWE PROFIBUS Interface USB Connector Connector w L3 LO L3 I Ep Expansion Expansion Oscilloscope RAM Cache Connector Technology JUA ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 13 150 2 2 Support power connectors In normal cases ProfiCore Ultra does NOT require an additional power supply because of the USB connection If your laptop PC is for some reason not able to supply the power to the ProfiCore there are 2 options 2 2 1 Micro USB connection This requires an additional USB port of your laptop PC The Micro USB cable is provided with the Troubleshooting Toolkit 2 2 2 Adapter The adapter has to supply 9 V 500 mA with a power plug according to NES J 21 NES J 21 W NES J 210 XNES J 210 The adapter is NOT supplied with the product Plug information Opening 6 0 mm Center pin 1 95 mm 2 3 Expan
81. assignment This message is used to verify the desired modules and specify the size of the 1 0 data to be transferred in the Data Exchange message This message is used to signal to a master the current state of the DP slave It is considered the most important message of the DP protocol The diagnostics message gives information like Parameter Fault Ident number or user parameter are incorrect or not accepted Configuration Error The module desired selected is not supported Watchdog ON OFF Parameter Requested The slave is ready to be re parameterized Master address Ident Number This message is used to signal to a group DP slaves in one single message The Global Control message can activate functions like Sync Activates the Sync mode and causes the DP slave to update the slave output data to the slave application at that particular moment only Freeze Activates the Freeze mode and causes the DP slave to update its input data from the slave application at that particular moment only Unsync De activates the Sync mode UnFreeze De activates the Freeze mode Clear Used to signal to all slave stations that the master is in the Clear mode This message is used to change the DP slave address This function is used for devices that do not have dipswitches to setup the station address or when dipswitches are not possible due to ingress protection or physical limitations Retrieves the configurat
82. at has elapsed before the current message is send If the current message is a response it is called the slave Tsdr slave response time ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 6z 6 0 of Co e oo oOo ez oO OO z LO FF OO O 10 oo 00 oO 4 O OO oo 4 oo OO OO 4 39 62 OF 4 z3 EF lC 622 60 17 oO OC oo 5 BB 44 SE 5 ob 75 Cz Units 24 hour notation Bit Time Microseconds Milliseconds Seconds Bit Time Microseconds Milliseconds Seconds Bit Time Microseconds Milliseconds Seconds Column Attention Frame Addr Service Msg Type Req Res SAPs DataLen Data Interpreter FC Station Description The Attention header gives more information on the message or possible reason for a disturbance or error in the recorded message See paragraph 6 1 1 Attention column The Frame specifies the frame type of the message See paragraph 6 1 2 Frame column The Addr column specifies the source and destination address of the message Requests Source Destination Responses Destination Source An ACK message does not contain addresses so this field will be empty The Service column specifies the type of service of a message The information is extracted from the FC byte when available only valid for SD1 SD2 or SD3 messages See paragraph 6 1 3 Service column for requests and 6 1 4 Service column for responses The Msg Type
83. ata Exchange Req 4 2 ACK ea Short acknowledge Res 2 comments SD2 3 gt 43 SRD HIGH Data Exchange Req z 2 SD2 3 lt 43 Data Exchange Res 2m Activity log Message data Setup Search Search Up Search Down Raw frames Fa nee eens Reon pte fees Poste eyes Ps Fig 19 ProfiTrace message recording Ea ProfiTrace 2 for ProfiCore Ultra V2 0 beta c 2004 2007 PROCENTEC File Action Filter Trigger Toolbars View Report Settings Help ProfiTrace ScopeWare Bar graph Network Manager ProfiCaptain Load Data Save Data File viewer Setup record trigger Start message recording Stop message recording Set record fiter Set view fiter Init ErofiEore Ultra Info Panel Framestructure SD1 message Source address 3 Destination address 6 Model Name JKT6IDP ACMI Live list EJ Messages E Messages Activity log Message data Pluain output Fig 20 ProfiTrace message recording Close ProfiCore Ultra Auto detect baudrate Set baudrate Ves xD SSS System activity Live list Message recording X Record to file x ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC Record and View filters D 2007 10 Data Exchange Req Li RENE HUN PARUS 2007 0 Start and Stop message en 2 1 PROFIBUS DP O Message 10 Data Exchange Req 2 Data Exchange 10 recording Date Exchange Res 6 10 us Req Selection to Swit
84. c Many process or factory plants nowadays use SCADA or Asset management software to get an overview of the production status and application alarms However they have no insight on the PROFIBUS health and behaviour which could indicate a potential shutdown This information contributes heavily to the installation uptime Using ProfiTrace OPC it is now possible to get the real live state of your PROFIBUS network directly in your SCADA system allowing maintenance engineers and operators to react quickly to any PROFIBUS related alarms or irregular events coming up on the screen The opportunities are vast and we are just discovering the possibilities what it could contribute to your asset management You can display ProfiTrace tags in a SCADA HMI package or link it to an SMS email client and sent a message when something happens with the PROFIBUS installation or even generate your own report in MS Word Excel Every application that acts as OPC client can approach the ProfiTrace tags It does NOT corrupt the PROFIBUS cycle time because the information comes from busmonitoring listening 13 1 Installing the OPC drivers The PC that runs ProfiTrace has to be prepared for OPC by installing the drivers see Fig 48 The installation process of the OPC drivers takes a relatively long time fit C appProfitrace 2 5 0PC_Redistributables File Edit View Favorites Tools Help Qs X gt x 7 j Search gt Folders fi Address C app Pro
85. catalog has not been updated yet the Model Name and Implementation Type are empty See 3 10 for updating the catalog The network scan will now also fill the Live List of ProfiTrace with the device names This is extremely useful Class 2 commands dialog x Set Change Slave Address Diagnostics Inputs amp Outputs Get Configuration Network scan s 3 present but identnr is unknown on DP station Jtnr Ox05FB Station on address 32 has identnr B 754 Model Name 750 333 WAGO Vendor Name WAGO Kontakttechnik GmbH Implementation type DPC31 ASIC Station on address 36 has identnr 0x8064 Model Name ET 2005 IM151 Vendor Name SIEMENS Implementation type SPC3 Station on address 46 has identnr FF2E Model Name BL6 GW DPY1 Vendor Name Hans Turck GmbH amp Co KG Implementation type lt unknown gt NN Station on address 125 has identnr 0x6964 Model Name Blackbox Vendor Name 4CMI Implementation type LSPM2 Click on Start scan to start the scan 12 2 2 Set Slave Address With the class 2 Set Slave Address function ProfiCaptain can set a new bus address over the PROFIBUS at the slave device that support this feature Most slave devices that support this function do not have dipswitches or rotary switches PA devices must support it The default address for new or serviced devices is 126 ProfiCaptain offers you the option to set devices back to 126 It depends on the slave device if it has to be powe
86. ch 10 35 38 556 SD4 3 53 Token pass Pass token 10 35 38 556 SD2 3 gt 27 SRD HICH Data Exchange Req 4 to this screen 10 35 38 556 ACK TOI Short acknowledge Res 10 35 38 556 SD1 3 gt 6 SRD HIGH Data Exchange Req d 10 35 38 557 Repeat SD1 3 gt 6 SRD HIGH Data Exchange Req 38151 21 Nov 2007 10 35 38 557 Repeat SD1 3 76 SRD HICH Data Exchange Req 38152 21 Nov 2007 10 35 38 557 Repeat SD1 3 gt 6 SRD HIGH Data Exchange Req 38153 21 Nov 2007 10 35 38 557 Repeat sD1 3 76 SRD HIGH Data Exchange Req 38154 21 Nov 2007 10 35 38 558 Repeat lost SD1 3 gt 6 SRD HIGH Data Exchange Req 38155 21 Nov 2007 10 35 38 558 SD2 3 gt 43 SRD HIGH Data Exchange Req 2 38156 21 Nov 2007 10 35 38 558 sD2 3 lt 43 paca Exchange Res 2 38157 21 Nov 2007 10 35 38 558 sD2 3 gt 10 SRD HIGH Data Exchange Req im 38158 21 Nov 2007 10 35 38 558 SD2 3 10 Exchange Res 1i 38183 21 Nov 2007 10 35 38 559 SD2 3 gt 32 SRD HIGH Exchange Req 2 38160 21 Nov 2007 10 35 38 553 SD2 3 32 Exchange Res 38161 21 Nov 2007 10 35 38 559 SD1 3 gt 105 FDL Status Req 38162 21 Nov 2007 10 35 38 559 SD4 3 gt 3 Token pass Pass token 38163 21 Nov 2007 10 35 38 553 SD2 3 gt 27 SRD HIGH Data Exchange Req 4 38164 21 Nov 2007 10 35 38 559 ACK DI Short acknowledge Res 38165 21 Nov 2007 10 35 38 553 SD2 3 gt 43 SRD HIGH Data Exchange Req 2 38166 21 Nov 2007 10 35 38 559 SD2 3 lt 43 HE Data Exchange Res 27 5 3 4 Data inspection The data inspection is a
87. ch OFF a slave and analyze the values L Fix all faults Check if the Syncs have stopped ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 108 150 ASSIGNMENT 2 DOUBLE ADDRESS The Statistics can easily indicate a double address L Generate a double address and check it in the Live List and the Syncs in the Statistics L Go to the field Illegal responses to requests and investigate what happens on some masters this might not work El Fix all faults Check if the Syncs and the Illegal responses to requests have stopped ASSIGNMENT 3 CYCLE TIME Click on Reset All to clean up all the statistics Go to the field Data Exchange Interval msec What is the cycle time of the installation Switch a slave OFF or remove 8096 of the devices What is the cycle time of the installation ESTEE ER Fix all faults Check if the Syncs have stopped ASSIGNMENT 4 DIAGNOSTICS Click on Reset All to clean up all the statistics Go to the field Diagnostic msg res from slave when in DX Generate diagnostic events I O problem I O card removal etc and investigate this statistic Click on an address of this statistic that has a value and check the info panel Fix all faults Check if the Syncs have stopped and that the Live List does not indicate ERRERA diagnostics ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 109 150 15 4 Recording
88. ckport Cheshire SK12 1YY United Kingdom Hi Port Software The Hub 2 Martin Close Lee on Solent Hampshire PO13 8LG United Kingdom iTech Unit 1 Dukes Road Troon Ayrshire KA10 6QR United Kingdom mmm 4 oe qnc m HE ue noo a t mono eI D c3 en ed 421 486115900 421 486111891 jan snopko controlsystem sk jan snopko controlsystem sk 27 11 548 9960 27 11 465 8890 sales idxonline com www idxonline com 34 93 588 6767 xavier cardena logitek es www logitek es 46 451 74 44 00 46 451 89 833 hans maunsbach pol se www pol se profibus 41 0 34 426 68 32 41 0 34 426 68 13 max felser bfh ch www profitrace ch 886 2 87519941 9097 886 2 87519533 sales fulldata com tw www fulldata com tw 90 216 420 8347 90 216 420 8348 tolgaturunz emikonotomasyon com www emikonotomasyon com 971 4 3262692 971 4 3262693 sales synergycontrols ae 44 0 1625 871199 andy verwertraining com www verwertraining com 44 0 8452 90 20 30 44 0 2392 552880 sales hiport co uk www hiport co uk 44 0 1292 311 613 44 0 1292 311 578 sales itech troon co uk www itech troon co uk ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC Parkelect Ltd 84 Dargan Road Belfast BT3 9JU N Ireland UNITED STATES Grid Connect Inc 1630 W Diehl Road Naperville Illinois 60563 USA VIETNAM Bavitech Corporation 42 Truong Son Street Ward 2 Tan Binh District
89. clicking on a station in ScopeWare then the segment tree shows a User Scope Image after clicking on Show List This is the last viewed scope image in ScopeWare that was displayed For further instructions about the use of Scope images refer to paragraph 5 5 and chapter 9 Please note that some modes and features of ScopeWare are not available in the Network Manager view 11 4 Topology Scan The Topology Scan can be reviewed and started from the Network Manager Click on the Topology tab For further instructions about the use of the Topology Scan refer to paragraph 5 7 11 5 Saving loading and resetting You can erase all measurements in the Network Manager by clicking on Reset in the top left corner This can be useful when starting measurements on a new network or if you feel that measurements are incorrect due to changes in the segment while measuring e g termination switched on off It also deletes all names and other station properties ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 79 150 All measurements can be saved at any time by clicking the Save button Then choose a location to store the file The file will have a ptn extension and can be loaded later by clicking Load By default the ptn file will also be saved automatically when saving a message trace in ProfiTrace as shown here Save Data Select messages f All messages Messages in filter views C Ra
90. column specifies the higher level DP DP V1 and DP V2 messages See paragraph 6 1 5 Msg Type values The Req Res column indicates a request or response message The SAPs column specifies the source and destination SAP of the message Requests Source SAP Destination SAP Responses Destination SAP Source SAP The DataLen column specifies length of the user data of a message only valid for SD2 and SD3 messages and does not include SAPs The Data column contains the USER DATA of a message If the data is shown in RED it was interpreted to be invalid and displayed as RAW data Please look in the Attention column for the details This column interprets the content and meaning of the data Particularly for PROFIBUS PA devices this is useful as ProfiTrace can decode and visualize the floating point value and the description of the status byte In order to do this ProfiTrace needs to have sampled the Parameter message and Check Config message of a PA device FC byte of the message Selectable keyword from the GSD file This is only possible if a diagnostic message from this specific device has been scanned by ProfiTrace By default the keyword Model Name is used ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC Units e Req e Res e Decimal e Hex e Decimal e Hex e Decimal 58 150 Column Description Units SA The source address of a message DA The destination address of a
91. cur when a SAP Service Access Point at the device is not activated Negative acknowledgement for sent data resources of the remote FDL controller not available or not sufficient Reply data with low priority available Negative acknowledgement for sent data resources of the remote FDL controller not available or not sufficient Reply data with high priority available ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC Remarks Most of the time used for a regular Data Exchange response Most of the time used for a Data Exchange response and an indication that the device has diagnostics Response to an FDL Status Request Most of the time used when the GSD file is wrong and incorrect parameters are written Most of the time used when the watchdog has run out 61 150 6 1 5 Msg Type values MSG Type PROFIBUS DP Data Exchange Set Parameter Check Config Get Diagnostics Global Control Set Slave Address Get Config Read Inputs Read Outputs PROFIBUS DP V1 DPV1 Initiate Req DPV1 Initiate Res DPV1 Initiate NegRes DPV1 RM Req DPV1 Abort Req ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC Description This message is used to transfer 1 0 data from to the DP slave This message is used to set the parameters to the slave The first 7 bytes are the mandatory part containing a control byte MinTsdr Ident Number Watchdog factor and group
92. d PA SDN LOW Send Data with No acknowledge low priority SDN HIGH Send Data with No acknowledge high priority Most of the time used for a Global Control Broadcast REQ IDENT Request identification REQ LSAP Request LSAP SRD MCAST Send and Receive Data Multicast also used by DP V2 devices to respond with a Data Exchange Broadcast ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 60 150 6 1 4 Service column for responses The table below explains the possible values of the service types for response messages The top part lists positive responses the bottom part lists negative responses Service DL DH Passive Act NRY Act RDY Active RR RS RDL RDH Description Data response low priority The device acknowledges correct reception of the message and returns a low priority response Data response high priority The device acknowledges correct reception of the message and returns a high priority response Identifies a slave device Identifies a master which is not ready to receive and carry the token Identifies a master which is ready to receive and carry the token Identifies a master which is in the Token ring Reject Resource This can occur when the internal buffer of the device cannot contain either the data size of the request data or the communication handler is unable to process it because it is not fast enough Reject Service This can oc
93. dresses Fig 23 Bar graph The average amplitude should be around 5 V When there are bus problems the Bar graph will display different Voltage levels and the colour of the bars will change ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 48 150 Fig 24 shows an example of the Bar graph when the bus cable is missing termination or when there is a wire break The voltage levels are much higher because of the extensive reflections Fig 25 shows an example of the Bar graph when there is low impedance or short circuit in the bus cable The voltages are lower than normal and some bars are coloured red Gj ProfiTrace for ProfiCore Ultra V2 1 c 2004 2008 PROCENTEC ProfiCore Ser Nr xxxxx00002 z 15 x File Action Filter Trigger Toolbars View Report Setting ProfiT race ScopeWare Bar graph Topology Network M Ve ry h igh messag e amplitude AB Diff stable voltage 18 x Very low message amplitude Fig 25 Bar graph when it senses a low impedance ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC If a station is not active during the defined time out default 5 seconds the bar of that station will become grey to indicate inactivity This can also happen when the signal of this station is so bad that ProfiTrace cannot decode the message Fig 26 shows an example 9 0V 8 0V Z 0V 6 0V 5 0V 4 0V 3 0V
94. e 1 1 1 module 1 1 Erase Selected Module Internalinput and output addreses Total 1 0 for Data Exchange Inputs Outputs 7 Allowed maximum values Select the Max Inputs Mas Outputs module s and Max Data Available modules click on Add Max Modules 1 Name Inputs Dutguts Module Pim J 1 module 1 Add Module to Selectio Insert Module ta Selection Haw configuration data Co nfirms the selection oo o 10 Cancel Select the required modules and setup the parameters Click OK to confirm When back in the previous screen Tick active to enable ProfiCaptain to have Data Exchange with this slave device If slave is already occupied by another master ProfiCaptain can take over the device by clicking on Steal Slave Click OK to confirm ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 12 3 3 Status of the device If the device is setup correctly the indicator on the top right should now turn green Data Exchange M ProfiTrace for ProfiCore Ultra V2 4 c 2004 2009 PROCENTEC ProfiCore Ser Nr xxxx x00002 l xj File Settings Help ProfiTrace ScopeWare Bar graph Topology Network Manager ProfiCaptain Load Project Save Project Zoom in Zoomout Draw Wire Setup Master Class 2 Commands DP41 Class2 W atch Madify 1 0 GSD Network Sheet General Drives Switching
95. e to enable all master functions Click Close to close the dialog The only method to stop the master is to click on Offline or Close ProfiCore in the ProfiTrace environment The user can also select another master mode Here is a small description of the master modes which are compliant with the PROFIBUS standard OFF LINE e Nocommunication STOP e Token exchange FDL Status e Class 2 communication e No data exchange with the slaves CLEAR e Parameterization and configuration of slaves e Data Exchange without outputs e Outputs 0 GSD keyword Fail Safe 0 e No Outputs GSD keyword Fail Safe 1 e Sends Global Control Command with Clear bit ON OPERATE e Parameterization and configuration of slaves e Data Exchange with outputs e Sends Global Control Command with Clear bit OFF ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 87 150 12 2 Class 2 DP VO functions ProfiCaptain provides a simple user interface for DP VO class 2 commands to scan and diagnose devices on a passive or working network The following class 2 services are available Read inputs Read outputs Get configuration Set Slave Address Get Diagnostics ProfiCaptain will do only 1 class 2 function per token cycle This is to keep the cycle time of the network as constant as possible Class 2 functions can always be executed on all slave devices in the network without the need to configure these devices e Profit
96. eature not Supported Freeze mode active Ext diag bit v Watchdog is on Configuration fault v Station is slave Station not ready Static diagnostics Station not existent Parameter request Extended diagnostic overflow From the diagnostic message Cancel On the tabs on the top more status info from the device can be inspected ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC If the device has another colour something went wrong with the Data Exchange procedure The colour coding is the same as the Live List from ProfiTrace red and purple See 5 3 1 Black indicates the device cannot be found on the bus the master is not active or the device has been disabled 12 3 4 Info on Stealing slaves ProfiCaptain has a unique feature which allows it to steal a slave from its controlling master without having to interact with the controlling master in any way It could be that the device from the previous paragraphs has been stolen from another master This method relies on jamming the original master s Data Exchange telegram with a short transmission from ProfiCaptain at exactly the correct time ProfiCaptain then temporarily poses as the original master by using its address as the source and unlocks the slave ProfiCaptain then is free to capture the slave with the normal start up sequence Should the Steal Slave be disabled and deactivated in ProfiCaptain the
97. ed according to the PROFIBUS installation guidelines e tis assumed that there is at least 1 meter of cable between the stations e Only the stations in the current segment measurement point are calculated e You must know which devices are physically connected to the current segment and which are NOT 5 8 Network Manager The Network Manager is a tool to save and load oscilloscope measurements bar graphs and topology images You can use it to assign names to segments measurement points and stations These names will appear in the Report The Network Manager is particularly helpful when measuring a network with multiple segments These segments can be divided by repeaters hubs fiber optic couplers or other media converters It also helps analysing the oscilloscope measurements by showing min max values m ProfiTrace for ProfiCore Ultra V2 7 c 2004 2012 PROCENTEC ProfiCore Ser Nr 2000000013 Ele Action Filter Trigger Toolbars View Report Settings Help ProfiTrace Scopeware Bar graph Topology Network Manager ProfiCaptain Reset Save Load Current Segment Properties Bargraph Scope Image Topology Segment 1 Current Measuring point Property Value Measuring point 1 M abies EM Titlename segment 1 Show list Segment Type nnt sel vM Auto add stations tJ Stop Processing Segment 1 EE Measuring paint 1 E E 3 Master Er 2
98. ed in the Toolkit Ultra Plus and PRO License for existing customers already included in the Toolkit Ultra PRO ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 127 150 pee c e ana Manual pack 18010 e 5 Paper manuals e Latest software on USB card ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 128 150 23 Contents of the Troubleshooting Toolkit PROFIBUS Troubleshooting Toolkit Ultra PRO 38022 ProfiCore Ultra USB cable Ato B USB cable Ato mini for extra power supply if needed Credit card USB stick download your license on www procentec com licenses Tap Connector Manual Pen LILILILILILILIL PA Probe Ultra including 2 spare connectors green PROFIBUS Troubleshooting Toolkit Ultra Plus 37021 L ProfiCore Ultra USBcable AtoB L USB cable Ato mini for extra power supply if needed L Credit card USB stick download your license on www procentec com licenses L Tap Connector L Manual L Pen 26510 1 UI sicul ur al 2 6 0 User Manu profiTrace ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 129 150 24 Glossary Address Unique number of a device connected to the network With PROFIBUS this can be 0 to 126 127 is a broadcast address Analyzer Software tool to observe the protocol traffic Combi Analyzers can also inspect the signal quality Other term
99. ermination A powered resistor network at both ends of a segment to prevent reflections with PROFIBUS DP the termination has to be powered Topology In a communications network the pattern of interconnection between network nodes e g bus ring star configuration Vendor Name This is a keyword in a GSD file that describes the manufacturer of a product and can be 32 characters wide The configuration tool of the master displays this keyword in the catalog ProfiTrace displays the Vendor Name in the Live List when the GSD file of the device is available in the GSD directory and a Diagnostic telegram Ident Number of the device was detected on the bus ProfiCaptain displays the Vendor Name in the Slave Setup dialog window ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 135 150 25 Revision History Version 4 1 0 New chapter Network Condition Indicator New paragraph Network Condition Indicator Updated paragraph Statistics with descriptions of all statistics Updated the Distributor and sales offices list Version 4 2 0 New chapter Wizards Updated chapter Network Condition Indicator Updated chapter ProfiCaptain Minor textual updates Version 4 3 0 Added description of Diagnostics indicators in paragraph Live List 5 3 1 Improved explanation Risk Margin Updated chapter License System and added a paragraph about trial Updated chapter Hotkeys
100. es When a slave is lost the master cannot control it anymore Illegal responses to requests ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 41 150 This statistic shows the number of messages that a station has answered with an illegal corrupted message This statistic is only increased for an SRD or SDA request message If this statistic increases continuously for a particular station then there are probably 2 or even more slave stations assigned the same address The reasoning behind this conclusion is that when a slave answers to a request message it sends the data on the bus without checking that a collision corrupt the message caused by other slave stations also answering on the bus at the same time Sporadic increases of this statistic can be assigned to disturbances on the bus In that case other statistics should be looked at Data Exchange interval msec This statistic shows the actual time in milliseconds between 2 Data Exchange cycles to the same DP slave The time is measured between 2 Data Exchange answer messages This statistic is useful to determine the actual speed of a DP network identify underperforming DP slaves and to determine that a minimum desired cycle time can be reached with the current bus setup It can also be used to determine DP master card performance minimum reaction time of a slave MinSlavelnterval or when a DP slave sends too many diagnostics messages In general this s
101. ess STEP 6 Start a message recording and check the telegrams Only token and FDL status STEP 7 Check the waveforms in ScopeWare and the Bar graph Should have a higher amplitude than regular situations When the Live List Message recoding and ScopeWare show acceptable results ProfiTrace and the ProfiCore Ultra hardware function correctly ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 115 150 16 4 ProfiTrace and ProfiCaptain secrets Open a GSD file directly from the Live List When in the Live List the product name is visible you can right click on the device and select Show related GSD file for station address x Make sure Windows knows which editor to open for GSD E G etc extensions See the frames in raw format Click on RAW to toggle from decoded frames to raw frames Change the units from meter to feet and vice versa Click on Settings followed by Preferences followed by ScopeWare Topology and select meter or feet To reset all statistics and report logging without shutting down the ProfiCore Click on File followed by New In ProfiCaptain the device does not need to be connected to the virtual bus cable Every device which is placed in the configuration area will be part of the application ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 116 150 17 Technical data ProfiCore Ultra Technical data ProfiCore Ultra Dimensions and weight Dimensions L x W
102. est version of ProfiTrace and ProfiCore Ultra drivers Updates can be downloaded from www procentec com L Install the latest service packs and hot fixes for Windows L Boot the PC in the normal mode of Windows NOT in the safe mode L Under multi user versions installations of Windows make sure you have administrator rights D Do NOT connect the ProfiCore Ultra to the USB port yet ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 15 150 3 3 Setup program Insert the ProfiTrace credit card USB stick in a free port and or start Setup exe The install shield will display an introduction screen see next screenshot ProfiTrace2 BUSMONITOR OSCILLOSCOPE AND DP MASTER in T e i bs hoc DA USB Anvers vo Y d my xn 1 i M m ad ae 4 me E TAprofifnace Vag Je i __ Click Install to install ProfiTrace and the ProfiCore Ultra driver If you only want to install one of them just unselect the option you want to skip 3 4 ProfiCore Ultra driver installation The install shield will first install the ProfiCore Ultra driver In a window the results of the installation can be followed Blue letters are OK red letters indicate a problem The driver can also be installed manually by starting Driverlnstall exe PRE INSTALLING NEW driver ProfiCoreUltra device inf SUCCES driver C ProfiTrace_2_6_2_setup Install Drivers ProfiCoreUltra_device inf
103. fiTrace 2 5 OPC_Redistributables Folders x Mame Size Type Date Modified E ProfiTrace 2 5 COPC Core Components Redistributable x64 101 2 File Folder 17 03 10 08 25 as OPC Core Components Redistributable x86 101 2 File Folder 17 03 10 08 25 O dat files D exports C3 Filter settings O asd O asdlibtmp D inspect files network data O OPC Redistributables O ProfiCore Ultra USB Ner search settings 3 QuickTime D Readiris Pro 11 HP e RegistryPowerCleaner EH amp Skype E Slysoft f li OPC redistributables B 32 bit drivers I Profitrace help amp manuals N 1 64 bit drivers is Driver Install for ProfiCore Ultra N End User License 4 ProfiTrace revision history fe ProfiTrace V2 5 O SpeedFan C2 TomTom HOME 2 Vodafone Mobile Cond winzip E O Wireshark H 3 WordPerfect Office 11 E ws FTP CD AX MF ZZ E bedrijf O Config Msi 1 O Documents and Settings QC Films CD Images nm AA in mb all Fig 48 Location of the OPC drivers ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 98 150 13 2 Selecting OPC tags The OPC tag settings can be found in the Settings menu see Fig 49 a 3 ProfiTrace for ProfiCore Ultra V2 5 c 2004 2010 PROCENTEC Clase Profitore Ultra Auto d x w Fig 49 OPCtags in the Set
104. fiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 17 150 Select your destination folder ProfiTrace V2 6 2 InstallAware Wizard Destination Folder Select folder where setup will install files Install ProfiTrace V2 6 2 to Program Files x86 Profilrace V2 6 2 Required Disk Space InstallAware Click Next to proceed Select startup folder Select Program Folder Select the location where you would like to create new shortcuts Setup will add program shortcuts to the Program Folder listed below You may type a new folder name or accept the suggested name Click Next to continue Program Folder rofilrace Y2 6 2 Install this application for Anyone who uses this computer all users Only for me current user Install amp ware Click Next ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 18 150 Completing the Install ware Wizard for Profilrace V2 6 2 The InstallAware Wizard is now ready to configure ProfiTrace V2 6 2 on this computer Click Next to begin configuration Click Back to change settings Click Cancel to exit Click Next Completing the InstallAware Wizard for Profilrace V2 6 2 You have successfully completed the InstallAware Wizard for ProfiTrace V2 6 2 To dose this wizard cick Finish Click Finish to close the install shield After the installation process Prof
105. he DP bus Is it possible to analyze a PA segment LP YES if you want to use the ProfiCore Ultra on a PA bus attach the PA probe to the isi ProfiCore Ultra The PA probe transforms the extracted signals from the PA bus to Ty information which is fed into the ProfiCore Ultra Which USB version is supported ProfiTrace 2 supports high speed USB 2 0 I have a CP5611 card Can I run ProfiTrace on it NO ProfiTrace works only with the ProfiCore hardware ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 123 150 Reporting For generating a PDF file of the report can you advice a freeware PDF creator For creating PDF files you can use the freeware tool PDFill You can download it at www pdfill com What is the meaning of item 6 2 of the report Slaves that generated diagnostics while in data exchange Many devices can send diagnostic messages when for instance there is a module failure or an I O channel error In a fault free installation most devices will not send these messages It is a decision of the end user to decide if the content of a diagnostic message is critical What software can be used to view PTX files PTX files are used to save or load texts for the Report Generator in ProfiTrace Click on Generate Report in the Report menu and then Load Settings There you can select a PTX file Licenses HOT Where are license files installed License files are installed in a common application direct
106. he desktop You have now access to all previous GSD DAT plugin and configuration files After starting ProfiTrace scan the GSD files again also in ProfiCaptain Confirm File Replace Source c windows system32 drystore ProfiCoreUltra sys Target C A WINDOWS System32 Drivers ProfiCoreUltra sys The target file exists and is newer than the source Overwrite the newer file Fig 4 Warning prior to replacing drivers confirm with Yes ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 27 150 4 License system 4 1 Introduction For online operations you need a license for the parts you want to use Offline it can be used without licenses You can purchase a license for the following combinations e ProfiTrace 2 e ProfiTrace 2 ScopeWare Bar graph Reporting e ProfiTrace 2 ScopeWare Bar graph Reporting Topology scan e Every combination ProfiCaptain e Every combination CommDTM e Every combination OPC The license you have purchased now can later on always be enhanced with extra functionality 4 2 Characteristics of the license file name The license is defined by a file with the extension PLD The license file is related to the serial number of the ProfiCore Ultra On the bottom of the ProfiCore Ultra the serial number can be found It is a 10 digit number Fig 5 illustrates the serial number of the ProfiCore Ultra PROCENTEEC ProfiCore Ultra PROFIBUS
107. hy are slaves that are not in data exchange blinking in the Live List with a yellow background Your bus cycle is slower than the ProfiTrace update of the Live List You should make the update time higher You can do this in the settings menu Preferences Live List settings Assume station lost after Why are some devices in the Live List blinking from Red to Green The blinking devices are devices that have master and slave functionality at the same time Red means master Green a slave in Data Exchange Nothing is wrong But a lot of people make mistakes with the busparameters because they have to be identical on all masters ProfiCaptain We have slaves without switches to set the network address Can we use ProfiCaptain to do it over the PROFIBUS YES ProfiCaptain supports the SetSlaveAddress function to set the network address of DP and PA slaves Can I copy the GSD bitmaps into a common directory that ProfiCaptain can scan YES the bitmaps associated with the GSD files must be copied manually to the gsd directory Do not forget to generate the catalog again How can I remove a GSD file from the catalog To remove a GSD file from the catalog you need to manually delete the file from the GSD directory and generate the catalog again Settings gt Generate Catalog PA Probe and PROFIBUS PA I am using the PA Probe and when I trace messages I see MBP End del in the column Attention What does it mean It means that the PA Probe
108. iCore Ultra V2 9 c 2004 2013 PROCENTEC File Settings Help ProfiTrace Overview ScopeWare Bar graph Topology Network Manager ProfiCaptain Load Project Save Project Zoom in Zoom out Draw Wire Setup Master Class 2 Commay Glob Cmd Sync Uns GSD Catalog Filter GSDs wwW atch Maodify 1 0 2 SEE INE SEE 6 no ime E E General Drives Switch devices Er 1 0 be 750 333 WAGO C ET 2005 IM151 00 FX2N modular station C GPL TR4LGIS c L SC 16DO def DP e MT DP12 ue 7 7 SP 0 C ST1H PB Mitsubishi o Ventilansteuerung oo Valves E Controllers HMI MMI Encoders i NC RC Gateway PLCs Ident Systems Profibus PA 2 SIO4DP PRG Jun A Slave Info Modules dE file GSD Filename PROCE6960 asd Vendor Name PROCENTEC Model Name SIO4DP PROCENTEC pnm Ident Number Ox6960 lt Bitmap SIO4DP After dragging the slave device to the bus double click on the slave device to setup the address modules and parameters When the user is not sure if he has selected the correct GSD file he can compare the Ident Number from the slave info field with the info that was extracted during the network scan with the class 2 functions see 12 2 1 ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 92 150 Slave Setup Dialog
109. iTrace is ready for use however we recommend rebooting the PC ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 19 150 3 6 Connecting ProfiCore Ultra to the USB port After connecting the ProfiCore Ultra to the USB port the last installation process will start Found New Hardware Wizard Welcome to the Found New Hardware Wizard Windows will search for current and updated software by looking on your computer on the hardware installation CD or on the Windows Update Web site with your permission Read our privacy policy Can Windows connect to Windows Update to search for software Yes this time only Yes now and every time connect a device Click Next to continue Click Next to proceed Select the location of the drivers Normally the first option is sufficient Found New Hardware Wizard This wizard helps you install software for ProfiCore Ultra Device ra If your hardware came with an installation CD lt 4 or floppy disk insert it now What do you want the wizard to do Install from a list or specific location Advanced Click Next to continue Click Next to proceed ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 20 150 The driver is ready for use however we recommend rebooting the PC Found New Hardware Wizard Completing the Found New Hardware Wizard The wizard has finished installing the sof
110. iagnostics Hes SDl l 53 SBD HIGH Data Exchange Reg sp2 1 538 Dh pata Exchange Res SD 1 l 5z SBD HIGH Data Exchange Ber SDS l1 se BRO pata Exchange Res plm 1 Fig 35 Example of selected message columns The following columns can be selected for the message recording field Column Line FrameNr Timestamp Deltatime Idletime Description The Line header specifies the line number in the respective view This line number is independent of settings filtering and such The FrameNr header specifies the message sequence number and is used to indicate the sequence between individually sampled messages The FrameNr is not necessarily consecutively numbered in a view because filtering could have caused a message to be filtered out If a bookmark is placed additionally the text Bx is shown in which x is the bookmark number The timestamp is calculated on the basis of a starting moment the user has defined and subsequent messages add to a delta bittime to this beginning This means that the timestamp internally consists of 2 parts the time date and the delta bittimes that have passed It is the time from the first start bit of the previous message to the first start bit of the current message Note Filtering of messages can cause this time be larger than expected with consecutive messages The Idle Time is the inactivity between 2 messages It refers to the previous message and the time th
111. in high byte low byte order in memory As Unsigned32 but reversed in high byte low byte order in memory As Int16 but reversed in high byte low byte order in memory As Int32 but reversed in high byte low byte order in memory ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 96 150 12 4 2 Visualization types Visualization type Entry Decimal 100 1 5 only for float 1e5 only for float becomes 100000 Binary b1010 1100 b11001100 b10000 becomes 16 decimal Hexadecimal Oxe75a Ox78FE Ox1111 12 4 3 Automatic patterns ProfiCaptain offers 5 automatic patterns Increase Automatically increase by arg1 every X milliseconds approx at the given cycle time Decrease Automatically decrease by arg1 every X milliseconds approx at the given cycle time Bit Zig Zag Will move a single bit to the left and when the left is reached it will move to the right and back again Only for Unsigned datatypes Bit Walk Will move a single bit from a low to high If it has reached the highest bit it will restart on bit O Copy from input Copies a specified input address directly to an output ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 97 150 13 OPC server The ProfiTrace OPC Server offers a standardized interface to get the valuable ProfiTrace information like device status statistics and process variables into applications that carry an OPC client such as SCADA Excel et
112. ings The PROFIBUS warnings field displays every PROFIBUS event captured during measurement It also indicates the traffic light state for the corresponding warning For example if the diagnostics bit is sent by a slave the traffic light will go to Yellow This is also indicated by a yellow button next to the PROFIBUS warning in the list The Warnings list displays the following events and the traffic light will react accordingly Warning event Traffic light Back to state green state Idle voltage low 0 9 V to 0 3 V e Yes Critical diagnosis Ext diag e Yes Configuration error e Yes Parameter error e Yes Risk margin low 60 to 40 e No Slave amplitude low just above limit 2 5 V e No Repeats e No Syncs e No Idle voltage below limit 0 3 V e Yes Risk margin below limit 40 e No Slave amplitude below limit 2 5 V No Illegals e No Slave lost e No The last column Back to green state indicates if the traffic light can go back to green during measurement after a problem is fixed After certain events e g repeats the traffic light does not go back to green The user ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 65 150 must acknowledge this event with the Reset button above the traffic light Pressing the Reset button also clears the warning list 3 Risk Margin The Risk Margin indicated in the Warning List shows how much margin Appt OS there is left in the worst detected signal in
113. ion ScopeWare ScopeWare ScopeWare Spur lines ProfiCaptain ScopeWare ScopeWare Short circuit break ProfiCaptain ScopeWare ProfiCaptain ScopeWare ScopeWare crossed wires Cable too long ProfiCaptain ScopeWare ProfiCaptain ScopeWare ScopeWare EMC noise problems ScopeWare ScopeWare ScopeWare 1 Meter rule ProfiCaptain ScopeWare ScopeWare ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 1 5 Detectable faults on PROFIBUS PA ProfiTrace 2 in combination with the PA Probe Ultra can be used to detect almost all faults in PROFIBUS PA networks The table below describes the sub programs you need to find specific faults it is assumed that the PA network has a link coupler and the ProfiTrace is connected to the PA segment Faults on PA General communication faults Double address Wrong address Missing device Device diagnostics Configuration faults PROFIBUS DP connection failure Bad status byte No termination Too many termination Short circuit break crossed wires EMC noise problems DC Voltage too low high Coupler power failure Running installation or a link that communicates autonomously ProfiTrace ProfiTrace or ScopeWare ProfiTrace ProfiTrace ProfiTrace ProfiTrace ProfiTrace ProfiTrace ScopeWare ScopeWare ScopeWare ScopeWare ScopeWare ScopeWare ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 10 150 1 6
114. ion data from the DP slave Retrieves the current input data from the DP slave Retrieves the current output data from the DP slave Initiates a class 2 acyclical connection with a DP V1 device Confirms that the class 2 acyclical connection request has been accepted The class 2 acyclical connection request has not been accepted Returns information on the SAP to be used for the Class 2 acyclical connection Requests the closure of a Class 2 acyclical connection 62 150 MSG Type DPV1 Read Req DPV1 Read Res DPV1 Read NegRes DPV1 Write Req DPV1 Write Res DPV1 Write NegRes DPV1 DataTransport Req DPV1 DataTransport Res DPV1 DataTransport_ NegRes DPV1 Idle Req DPV1 Idle Res DPV1 Poll PROFIBUS DP V2 DXB broadcast Isochrone spare Description Requests a read action on a particular slot and index The response of a DPV1 Read Reg Negative response indicating that the DPV1 Read Reg has failed A reason code and classification is also returned to determine the problem Request a write action on a particular slot and index The result of the DPV1 Write Req Negative response indicating that the DPV1 Write Req has failed A reason code and classification is also returned to determine the problem Request a write action on a particular slot and index and for the station to respond with the data on the same slot and index The result of the DPV1 Transport Req Negative response indicating that the DPV
115. ion of DP slaves ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 130 150 DP V1 DP V2 Drop cable DSAP ED Electromagnetic Compatibility EMC End Delimiter FC FCS FDL Frame Check Sequence Frame Control ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC DP V1 is the first extension of PROFIBUS DP VO DP V1 devices comply with the following features Device related diagnosis is replaced by status and alarms The first three octets of the user parameterization data are standardized Optionally these devices may support Acyclic communication MS1 MS2 If alarms are used MS1 is supported DP V2 is the second stage of extension of PROFIBUS DP after DP V1 DP V2 devices shall comply with the following features Data Exchange Broadcast DxB for slave to slave communication publisher subscriber principle lsochronous Mode time tick synchronized operating slaves e g drives Up and or download of Load Region Data domains Clock Control synchronization within slaves and Time Stamping Redundancy See Spur line See SAP See End Delimiter See EMC The extent to which an electric or electronic device will tolerate electrical interference from other equipment immunity and will interfere with other equipment Within the European Community as well as in other countries it is regulated by law that electric and electronic co
116. is also important that the idle state has minimum noise and 1 V level powered termination The spikes on the bits are normal and probably caused by the Tap Connector which is a small spur line Fig 37 shows an example of acceptable signals in ScopeWare Fig 23 shows an example of acceptable signals in the Bar graph ES ProfiTrace for ProfiCore Ultra V2 5 c 2004 2010 PROCENTEC ProfiCore Ser Nr xxxxx00001 l81xi File Action Filter Trigger Toolbars View Report Settings Help ProfiTrace Scopeware Bar graph Topology Network Manager ProfiCaptain Made B A Diff scale 1v Div M Ascale 1v Div Address N Trigger Message 7 igg Time Cursors Time scale 1usec v M SD1 v SD2 v SD4 F ShotAck ode Start of response v v Freeze v Cursors active J Show bit markers CheckBox2 oC bset trigger delay Level tigger V Bisina edge A CB Cursor 1 2 71 uSec i Cursor 2 3 37 Uec 7 CursorDiff 662 0 nSec Distance 788m Frequency 1510606 Hz Bit Factor 0 99 Bits Volt Cursors Cursor 1 2 64 V Cursor 2 2 89 CursorDiff 5 52 No noise duringidle state pu 09 lee CUINE Eu Cycle through devices x x EE EU 1 i 120 Fig 37 Acceptable RS 485 DP Signals ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 69 150 9 2 Termination missing or wire break When termination is missing or there is a wire break the
117. itch the slave OFF ON Swap the addresses of 2 slaves and investigate the Live List Create a situation in which the configuration of a slave is different than that of the master With some slaves you can just remove an 1 0 card Investigate the Live List Generate a diagnostic event I O problem I O card removal etc and investigate the Live List If the device is blinking click on it and investigate the info panel ERE ee NE Fix all faults after this assignment 15 3 ProfiTrace Statistics ASSIGNMENT 1 SYNCS STATION LOST AND RETRIES When a slave is NOT available and ProfiTrace is started afterwards you can t see it in the Live List For these situations the Statistics are a very important feature to check which devices are missing L Switch a slave OFF or remove the bus connector and investigate the Live List L Restart ProfiTrace and check the Live List mi Open the statistics view Go to the field Syncs and analyze the values L Switch ON the slave and analyze the field Syncs again Repeat this with some other slaves The Syncs will show you how many cycles the slaves were not available for the master You can also check how many times the slaves were not available L Go to the field Station Lost and analyze the values L Fix all faults Check if the Syncs have stopped E Click on Reset All to clean up all the statistics E Go to the field Retries total for this station swit
118. jing China CZECH REPUBLIC FOXON s r o Poln 367 460 01 Liberec 12 Czech Republic DENMARK ProSaiCon Jernbanegade 23B DK 4000 Roskilde Denmark comm emma Tmp Topy mmu FMA Tmp Topy e ET me HI XE LES em 31 0 174 671800 31 0 174 671801 info procentec com www procentec com 54 237 46 31151 54 237 46 31 150 santiago falcomer efalcom com www efalcom com ar 61 2 4964 8548 61 2 4964 8877 fritz woller issystems com au www issystems com au 61 2 4448 0466 61 2 4423 3232 sharee hazell pentair com au www profibuscentre com au 32 2 720 49 16 32 2 720 37 50 bloemen bintz be www bintz be 55 11 5561 7488 55 11 5093 2592 paolo wii com br www wii com br 1 403 225 1986 1 587 585 2828 admin streamlinepm com www streamlinepm com 56 0 41 2469350 56 0 41 2522592 rodrigopinto rpingenieria cl www rpingenieria cl 86 10 84766911 or 84787311 86 10 84766722 info procentec net www procentec net 420 484 845 555 420 484 845 556 foxon foxon cz www foxon cz 45 70 20 52 01 45 70 20 52 02 hfj prosaicon dk www prosaicon dk ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 138 150 EGYPT Mas Trading 37 105 Street Al Etihad Square Egypt ESTONIA Saksa Automaatika OU Peterburi Tee 49 Tailinn EE 11415 Estonia FINLAND Hantekno Oy Kalliotie 2 04360 Tuusula Finland FRANCE AGILiCOM Batiment B 1 rue de la Briaudi re Z
119. lder F Dropbox Je exports 5 11 2013 16 18 File folder Recent Places filter_settings 5 11 2013 16 18 File folder gsd 11 11 2013 12 26 File folder BE Desktop J gsdlibtmp 5 11 2013 16 18 File folder Libraries d inspect files 5 11 2013 16 18 File folder Documents Ji network data 5 11 2013 16 18 File folder a Music opc redistributables 5 11 2013 16 18 File folder Pictures di ProfiCore Ultra USB Driver 5 11 2013 16 18 File folder B Videos d search settings 5 11 2013 16 18 File folder j Homegroup __ M LICENSERTF 24 2 2013 16 11 RTF bestand 6KB gt on J 12 items Fig 3 ProfiTrace directory structure ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 3 8 Selecting the language of the user interface ProfiTrace 2 supports a range of interface languages Language files are stored in the APP directory and have the extension PLN ProfiTrace already provides a basic set of languages but additional language files can be downloaded from the PROCENTEC website and copied in the APP directory Click Settings followed by Language to obtain a list of included languages English Chinese ProfiTrace will display a list of detected languages files which are located in the APP directory Click on the preferred language that is included in the current installed version followed by OK ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 23 1
120. m a slave device Class 2 commands dialog E x Set Change Slave Address Diagnostics Inputs amp Outputs Get Configuration Network scan QUE wit Li CICHAIT nande Decoded configurati formation Select an address P Get configuration tab sapere ee Ne E Identifiers 1 Update the 00 pj 17 17 CC 79 01 e configuration data Raw configuration data Interpreted configuration data j i3 sjsjsjsjajsje s s s s Close Select an address and click on Get Configuration to update the configuration data 12 2 5 Get Diagnostics With the class 2 Get Diagnostics function ProfiCaptain reads out the last update of the diagnostic information from a slave device ProfiCaptain will try to decode the diagnostic information by means of the GSD file information or the scheme of the standard Class 2 commands dialog Update the diagnostics Ident Number B754 hex Extended diagnostics 19 bytes Contains 3 diagnostic blocks Block 0 Identifier related 8 bytes 43 08 00 00 00 00 00 00 00 Module 3 has diagnostics Block 1 Device related 7 bytes 07 40 00 00 00 00 00 Block 2 Channel related 3 bytes 83 40 A8 Module 3 channel 0 input Type Word Error Lower limit exceeded Raw diagnostic data read directly from the slave device Interpreted diagnostics Select an address and click on Get Diagnostics to update the diagnostic dat
121. measurements Bargraph values STEP 6 Record all PROFIBUS messages for 5 seconds and save files STEP 7 Record PROFIBUS messages with errors illegals repeats for 1 minute and save files if no errors repeats are detected no files are generated STEP8 Generate a Report in PDF format STEP9 Generate a ZIP file and include all generated files STEP 10 Generate a folder in C Users Public Documents procentec profitrace wizardoutputs dateofscan and place all the files in that folder If you have a question about a PROFIBUS network or segment and you want to have it analysed by our PROFIBUS Support professionals we encourage you to send the ZIP file to support procentec com for analysis 8 3 Wizard Scan Inactive Network During normal and correct operation of stations in a PROFIBUS network ProfiTrace cannot display slave information in the Live List or Network Manager other than the address The software must capture the Ident number before it can identify the slave and retrieve information from the GSD library The Wizard Scan Inactive Network can do this automatically for you Make sure no other master is active on the network The steps performed by this wizard are STEP 1 Clear all data same as File New in the menu STEP 2 Initialize the ProfiCore Ultra if it is not initialized yet STEP 3 Detect the baud rate to check if the network is active if so the Wizard stops STEP 4 Start ProfiCaptain DP master
122. messages ASSIGNMENT 1 STARTING A MESSAGE TRACE L Make sure the installation works properly No Syncs Retries etc L Click on Messages should be an empty screen L Click on Start message recording The screen should now be filling up with messages and on the bottom you should see an indication how full the message buffer is L Click on Stop message recording to stop the recording p Investigate what you see Timestamp Frame Addr Service MSG type SAP Datalen Data ASSIGNMENT 2 SEARCH FUNCTION Click again on Start Message Recording Switch a slave OFF Click on Stop message recording Click on Setup Search Search for Repeated messages and click OK Click on Search Down You should have detected the moment of lost TETERE Fix all faults Check if the Syncs have stopped ASSIGNMENT 3 TRIGGER FUNCTION ON RETRIES In case of sporadic disturbances it is important to use the trigger function In this assignment a trigger on retry messages has to be set Click on Messages Click on Trigger followed by Setup message record trigger Set Enable Retrigger 10 Messages before 10 Messages after do not limit off Click on Setup trigger and select repeated message Click on Start Message Recording should be an empty screen Switch a slave OFF screen should be filling with 20 messages Investigate what you see E E Pl HS ENG Fix all faul
123. mponents and equipment comply with basic standards such as IEC 61000 6 2 or IEC 61326 or corresponding individual product standards This byte identifies the end of a PROFIBUS message and has a fixed value of 16 Hex See Frame Control See Frame Check Sequence Fieldbus Datalink Layer Layer 2 of PROFIBUS It is a field in the PROFIBUS message that holds a checksum to check the integrity of the message It is simply the sum of the bytes Checksum DA SA FC DU mod 256 This is simply the bytes added together and divided by FF Hex 255 This is an integrated function that is normally performed by the PROFIBUS ASIC The Frame Control field specifies the type of message request response acknowledgement type of station passive or active slave or master priority and acknowledgement successful or unsuccessful 131 150 GSD file Generic Station Description It is provided by the device manufacturer and contains a description of the PROFIBUS DP PA device GSD files provide a way for an open configuration tool to automatically get the device characteristics HSA Highest Station Address The highest address to which the master will look for new masters This is done with the FDL Status message It has nothing to do with the configured slaves Default value is 126 but the end user can decrease it to a lower value We recommend leaving it on 126 in order to display not configured slaves in the Live List This value does not
124. n ne dre n theatre ee de 92 ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC I3 14 15 16 17 18 19 20 Ed a 23 24 25 26 27 28 9 30 ID idle FV OTIS OID Omm 92 T Addi GEVI CEE een een en en ee E eee eee 92 12283 8 AUS Or the Ee a a E E A 94 12 39 IA IG ON SAIS Ne a EE NETE Na 95 12 4 Cae D OS denen a a A RERUM E RU UNN DR OE URPERUMDU CDAEU NNI OE 95 RD AE ND ose pos ne ws lg ca hs alga cm ee mca eles mae 96 124 2 Visualization WY DES sises EE tas docs hutenetanieeiaateasdeiancedestonun dpa une CUTE aliens 97 2A Automa patter Sernin o sed nel Ed REI oem ane le an dr DER ROSEO vadum lot vba ad aie 97 RE i EE 98 13 1 Installing the OPC drivers iogcuccesaskiur tuta aon RE It REN YENIU BERSER stone casa retrace ere 98 USES 001759186 PERRO 99 13 3 Activating the OPC Server a Sn etree mta e toco ae a ai CD SUE dE 100 id its 103 14 1 Installing the drivers and DTM server sise 103 14 2 Setting up the PCD SErVel ccccccssecccesseccceseccceesececenecccseececeusececaecesseececsueceeeenecesseesessuecetseneeets 104 14 3 Using the CommMmDTM PRRRRTRRE 104 Hcc a a EE E EE EET 106 Die USE SOC e A E E E A A E a ne E E T E 106 182 ProT CE DIV LR a EE a 108 15 oa FURL Ges Simo ASUS RT mmm 108 15 4 Recording messages ccccccssccceseccesecccscecenceceneceenececenceceneceeeeseeceeeecesenceseneeseneceseecessueeteneetegecenes 110
125. n this frame nr only shown if it is not an error message repeat or sync The information transferred from the ProfiCore Ultra to the PC was not fast enough in order to be processed completely 59 150 6 1 2 Frame column PROFIBUS has defined the following message frames Frame Description SD2 The SD2 message contains user data and is variable in size It is the most common PROFIBUS message SD4 The SD4 message is a token message It is used to send the token to another master or to itself when there are no other masters active on the bus SD1 The SD1 message does not contain user data It is most of the time used to check if a device is available ACK The ACK message is a single byte response message also called ShortAck or OxE5 The Ack message is used to positively acknowledge a request SD3 The SD3 message has a fixed size of 8 user data bytes The SD3 message is NOT used anymore 6 1 3 Service column for requests PROFBUS has defined the following request messages Service Description Remarks Token pass Token pass message Only with SD4 messages FDL Status Identify a device on the bus Only with SD1 messages SRD LOW Send and Receive Data low priority SRD HIGH Send and Receive Data high priority Most of the time output data to PROFIBUS DP PA devices SDA LOW Send Data with Acknowledge low priority NOT used by DP and PA SDA HIGH Send Data with Acknowledge high priority NOT used by DP an
126. nager can display the current Scope signals but it also saves the minimum and maximum amplitude measurements This is a helpful tool for troubleshooting your network To show these signals click the Scope Image tab select the station address under investigation and unfold the tree on the left m ProfiTrace for ProfiCore Ultra V2 7 c 2004 2012 PROCENTEC ProfiCore Ser Nr 2200000013 File Action Filter Trigger Toolbars View Report Settings Help E Segment 1 Measuring point 1 ProfiTrace ScopeWare Bar graph Topology Network Manager di aptain Fe EL 3 Master Reset Save Load E EEE b Slave Current Segment Properties Bargraph Scope Image Topology H AB Diff voltage Segment 1 Mode B A Diff scale 1v 4 Div E AB Diff stable voltage Borri Time scale 1 uSec vl 7 7 7 User Scope Image easuring point Y i 3 Trigger Free running Level trigger Trigger Mode mo ACIES ru Lastviewed Show list EE 28 Slave M Auto add stations Stop Processing E AB Diff voltage H AB Diff stable voltage XP Segment 1 E X Measuring point 1 a m 3 Master E AB Diff voltage Last Ni Min Ls bf AB Diff stable voltage B H 6 Slave 12 Slave 28 Slave Live List 11 3 1 User Scope Image If you have used the message trigger for scope signals of individual stations in the ScopeWare tab e g by double
127. nbbnbbisadoanhbssanaadmmnbbaaiownbimbbosonsamsbaddannineenewsins 7 LL lntfOOHUC CUOI secari espns GN VER NI CN Vnd SH UP GUN Vm DEUM 7 1 2 Product features ceeccccesscccceseccceesececeeccceeuececeuececeeececeeuececsuneceesueeesenecessuacetsuseseseucetsenecetseneeetees 8 1 3 Application Al CAS acini rH RUE VIEPIE UIT Ode ui Ces uU DI Dene Ei IU EROR DIE S iM T TEPFUDI GNU Me PUPPI LSU MEME OE 8 1 4 Detectable faults on PROFIBUS DP ices 5 o eotab are rusa Re RE EVER F Fa ES apuYAP GEN Fen e SE YES E Vo dedans CYREREN E Vo ea eoi i eP Es 9 15 Detectable faults on PROFIBUS PA sance Ge Mk pPXT9E Ma TRU ERA Ua oeneto tete PA eo TUR ET Or PEU pK a ETE 10 r6 SYSTOLE COU IFCCS ER EE 11 1 7 PROT ACE SUC Ue a a ane A et a de a nb 12 2 xiij e fale hc ge eer een ene Re eee Ee T 13 2L o merna SU CE eee a eee ee ee 13 22 SUPPO POWE CONECTO S anniren an ae E E E 14 PATI NICLO USB COMECON MM Tem 14 22 2 PA T E A E PMID E E E E eee rer 14 2o PONIO ONN C OT oa ODE Lm 14 B Sornwasreanstallaton Inepte WIndows 7 Pr tart ue Utt Bla Ur oe ou be Mp PUEDE 15 S L Installation procedure nes E RUN EM Units vin a o RES UEN SN IN NAE eme E AA Vl Su US CEN Quit b UR EYdN EN INA EHE NR 15 23 2 PIO CO HS EATA CON a a stava E Ohm rase ee ce ae e no 15 D DOCU FOR Fal iat nan cas nsc anneau E age ta un ee tn tte an io et 16 3 4 ProfiCore Ultra driver installation nr nes nnns 16 Bo Pr lrace SOA OR a a a MN mda M on 17 3 6 Connecting ProfiCore Ultra to the U
128. ng the devices over the segments Select one of your segments set current measuring point and generate the topology You will see that only the devices on the specific segment are visible How can I improve my Topology Scan results There are cases where the Topology Scan does not work as expected The topology is calculated with the help of a generated distortion on the segment and is therefore sensitive to the signal quality of the segment itself To make the Topology Scan more successful please TURN ON THE TERMINATION SWITCH OF THE TAP CONNECTOR before starting the Topology Scan This will add an extra termination to the 2 existing termination resistors at both ends of the segment Do not forget to turn off the termination switch when finished Note Because an extra termination is added to the network this must be done in a stable and reflection free segment This reduces possible communication disturbances Hardware requirements Can ProfiCore Ultra overload the bus when it is attached to a running installation ProfiCore Ultra is designed and produced around the latest RS 485 technology 1 5 of a standard bus load This means the load of ProfiCore Ultra can be ignored on a full bus segment Spur cables are also no problem because the USB cable is the path to the PC 5 meters ProfiCore Ultra can be connected very close to the network and the PC can be on a distance from the tap point The ProfiCore Ultra has an RS 485 interface for t
129. nge Frame Nr Bookmark Start eNe bookmarks defined End No bookmarks defined Auto save companion files v View filter cfilename viewfilter ptf Record filter zfilename recordfilter ptf Datainspection settings Flename datainspection ptij Network manager data filename networkmanager ptn Cancel 11 6 Creating anew measuring point It is generally a good idea to measure both sides of a PROFIBUS segment at the start and at the end This means you need to manage Current Segment the scope signals in some way otherwise the Report will be difficult to Segment 1 Interpret Current Measuring point After clicking on Show list you will see all stations in the segment tree Star of segment at maste Show list on the left This segment tree has a measuring point You can change the name of the segment and measuring point Click on the item an go to Properties then enter a name Souto add stations M p M Stop Processing Next make sure to check Stop Processing This disables the recording E S Segment 1 function of the Network Manager Now you can safely move your ProfiCore Ultra to the new Measuring Point e g end of the segment If you do not click Stop processing new measurement data will be added to the first measuring point H 28 Slave Make a new Measuring point by right clicking on Segment 1 and choose Add Measuring Point
130. nose by means of the reflection An easier method is to look at the idle line Instead of being 1 V itis now going in the direction of 0 5 V when you have 1 termination that is not powered It will be O V when both are not powered Fig 43 shows an example of a termination that is not powered i ProfiTrace for ProfiCore Ultra V2 5 c 2004 2010 PROCENTEC ProfiCore Ser Nr xxxx x00001 ay TS Leveltnager fv si Cursor 1 651 5 nSec Cursor 2 300 5nSec 3M ori 2 Distance 41 8m ag egue 1 Gad H Bit Factor 0 53 Bits Volt Cursors Cursor1 0 00 Cursor2 057 CursorDiff 0 57 V Fig 43 Not powered termination ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 9 7 EMC EMI EMC EMI disturbances are easy to recognize The deviations in the signals pop up on irregular places With the static disturbances like termination fault or short circuits it is visible in every bit Fig 44 and Fig 45 show an example of typical EMC EMI disturbances e Profitrace for ProfiCore Ultra 2 5 c 2004 2010 PROCENTEC ProfiCore Ser Nr xxxxxOOOO1 File Action Filter Trigger Toolbars View Report Settings Help Profil race Scope are Bar graph Topology Network Manager ProfiCaptain 5 x Mode BA Dit El B A Diff scale Jiv7 bw J scale 1v D Time scale 1 uSec i zH Fsi SD Lar SD X
131. nts If ProfiTrace captured an Ident number of a station and the correct GSD has been loaded in the library see paragraph 3 9 the station name will appear in the list m ProfiTrace for ProfiCore Ultra V2 7 c 2004 2012 PROCENTEC ProfiCore Ser Nr 2000000013 File Action Filter Trigger Toolbars View Report Settings Help ProfiTrace Scopeware Bar graph Topology Network Manager ProfiCaptain Reset Save Load Current Segment Segment 1 Current Measuring point Se eS oe F t val Measuring point 1 L QM Titlename Segment 1 Segment Type Henot seb i Properties Bargraph Scope Image Topology Show list vM Auto add stations Stop Processing Segment 1 EA Measuring paint 1 ED 3 Master Fig 47 Generate station list in the Network Manager If you click on a station in the list you can edit the details in the Properties tab ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 77 150 ProfiTrace for ProfiCore Ultra V2 7 c 2004 2012 PROCENTEC ProfiCore Ser Nr 20000 Ele Action Filter Trigger Toolbars View Report Settings Help Profil race Scopew are Bar graph Topology Network Manager ProfiCaptain Heset Save Load Current Segment Properties Bargraph Scope Image Topology Segment 1 Current Measuring point Measuring point 1 Show list v Auto add stations Stop Processing Pro
132. ofiTrace structure All processes of ProfiTrace run parallel The user can easily switch to a process and inspect the information Network data file Master statemachine Oscilloscope 2d E23 07 M23 RII TUE g Statistics Bar graph Data inspection Topology scan Network manager Record filter ProfiCaptain Record trigger Messages View filter Messages with view filter Message file PC Laptop Windows Fig 1 ProfiTrace processes ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 12 150 2 ProfiCore Ultra The ProfiCore Ultra is the required hardware to use ProfiTrace 2 It has a robust industrial housing and translates PROFIBUS to USB and vice versa Because of the USB interface ProfiTrace 2 can be used on field laptops as well as desktop PCs The USB interface also eliminates spur lines ProfiTrace 2 can be connected almost directly to the bus line and the laptop positioned on a distance This is a perfect measurement solution for high speed networks When ProfiTrace 2 is in the analyzer mode it passively records the data traffic It does NOT behave as a master or slave When ProfiCaptain is activated the ProfiCore Ultra acts as a master and transmits messages on the bus 2 1 Internal structure ProfiCore Ultra has an isolated RS 485 interface DB9 connector and is equipped with a high speed digital oscilloscope that is able to c
133. ome wires and if possible a suitable plug which will serve as the link between the PA coupler and PA Probe Fig 11 Attaching the PA Probe to the ProfiCore D The ground lead S has to be used as well and it is essential that the adapter of a laptop is grounded this is not valid for battery powered laptops ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 35 150 5 1 4 Attaching the PA Probe to the PA installation Screw attach the connected leads from the PA Probe to the PA installation see Fig 12 The recommend location is the PA coupler The PA Probe has NO imposed polarity for the PA signals but the shield ground S has to be connected with the coupler to obtain a high quality measurement Fig 12 Attaching the PA Probe to the installation D The PA Probe is NOT Ex certified and only suitable for safe zones It can logically operate in an Ex environment but safe behaviour is NOT guaranteed ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 36 150 5 2 Starting ProfiTrace 2 After starting up the ProfiTrace software the screen as in Fig 13 should appear Click on Init ProfiCore Ultra to start the software When you have a PA Probe attached to the ProfiCore Ultra it will be automatically detected 3 ProfiTrace for ProfiCore Ultra V2 1 c 2004 2008 PROCENTEC Setup record trigger start message recording Stop message recording
134. on 1 5Mbps STEP 5 Scan the network 3 times it sends GetDiagnostics to every address STEP 6 Master stays online for further measurements and analysis ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC No files are generated by this Wizard 68 150 9 Oscilloscope measurements RS 485 DP PROFIBUS DP is high speed digital data communication which means a multi meter is NOT useable to measure the signal quality An oscilloscope is required to verify the electrical signals on the cable and essential to detect noise reflections termination problems wire breaks etc The difficulty is how to identify deviations This chapter describes example measurements on RS 485 DP which are made with ScopeWare You can compare them with your measurements at an installation Important is that you are aware of the propagation time on the cable With PROFIBUS this is about 4 2 ns m Disturbances travel with the same propagation time By measuring the width of the reflections we can conclude where the disturbance is physically located ScopeWare can do this calculation for you Before you continue reading make sure you understand ScopeWare by reading chapter 5 5 9 1 Acceptable signals Acceptable signals are almost real square waves with average amplitude of 5 V When the amplitude is higher and the signals appear to be square waves it is still acceptable modern RS 485 drivers can generate higher amplitudes It
135. op the file recording simply choose Action Stop file recording ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 64 150 7 Network Condition Indicator The traffic light style overview age indicates with eas colours ProfiTrace for ProfiCore Ultra V2 9 c 2004 2013 PROCENTEC ProfiCore Ser p 8 y File Action Filter Trigger Toolbars View Report Settings Help how healthy the PROFIBUS system ProfiTrace le Overview ScopeWare Bar graph Topology Network Manager IS Load Data A ata File viewer Setup record trigger Start message are Ultra Auto detect baudrate Set baudrat This chapter describes the rules for Live ist Ss oe the traffic light when the colour info Panel no changes and if it can change back to green It also explains the measurement details Traffic Light color indication in overview tab 7 1 Measurement time and reset button As soon as the ProfiCore Ultra is initialized the timer starts This also happens if the ProfiCore Ultra is not yet connected to a PROFIBUS network You will see the start time and the measurement time The reset button in the Overview window will reset all the timers statistics and measured scope signals Bar Graph info as well as the Network Manager data It has the same function as File New in the main menu You can use it to restart the measurement 2 PROFIBUS Traffic Light and warn
136. opology overview creator for DP e ProfiCaptain Class 1 and 2 DP master All modes work parallel Navigating to another mode will NOT erase the information from the previous mode 5 3 Busmonitor Analyzer ProfiTrace itself is an analyzer to display a Live List record messages view statistics inspect data etc see Fig 16 3 ProfiTrace II for ProfiCore Ultra c 2004 2007 PROCENTEC File Action Filter Tri settings He Fig 16 ProfiTrace functions ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 39 150 5 3 1 Live List Colours make it easy The Live List is a matrix that continuously lists all the available devices It is directly visible which devices are troublemakers With different background colours the status of the devices is displayed see Fig 17 e Green Device is in Data Exchange e Yellow Device is lost e Red Parameter fault e Purple Configuration fault e Nocolour On the bus but not in Data Exchange The Live List can also generate the product name of the devices when a diagnostic message is captured CRE with the GSD library La df tor Prot jn V25 1 c 2004 2010 PROCENTEC Identitumbers pid Fie Acton re me Der Ven Report Settings Help PioliTiace Scopewame Bar gagh Topology Network Manager ProtCaptain Set new er
137. ory this used to be the app directory On Windows 7 it is usually located at C ProgramData procentec proficoreultra On Windows XP it is usually located at C Documents and Settings All Users Application Data procentec proficoreultra Note the common directory is usually a hidden directory When order ProfiTrace without ScopeWare Topology scan and Bar graph can buy these licenses later YES licenses for every single software option can be purchased at any time How can obtain a license file The license can be obtained in 2 ways 1 Connect the PC with ProfiTrace installed to the internet Click on Init ProfiTrace and follow further instructions 2 Download the license from our website Go to http www procentec com licenses and follow further instructions The license file has the extension PLD and can be installed on all PCs ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 124 150 Live List In the Live List do not see the device names only the addresses How can display them Only when a diagnostic message is transmitted an Ident Number can be trapped which ProfiTrace links to a GSD file that contains the device name You can generate a diagnostic message with ProfiCaptain Join the network as an additional master and do a network scan in the Class 2 Commands You can of course also remove the power or connector from the device but that is not recommended W
138. p Profil race Scopeware Bar graph Topology Network Manager ProfiCaptain Load Data Save Data File viewer Init ProfiCore Ultra Setup record trigger Start message recording Stop message recording Set record filter Set view filter System activity Live list gt lt Message recording X Record to file x Info Panel Live ist El Messages S Messages with view filter applied Station statistics view e Data inspection Reset station Reset this statistic Reset all Activity log Message data Plugin output Fig 18 Statistics showing the Retries If the statistics do NOT show deviations the installation is on the 1st degree OK Here it stops for the technician who is only interested in a quick feedback The advanced technician can proceed with a message recording and an inspection of the signal quality ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 5 3 2 1 Resetting statistics If you want to reset certain statistics which have been collected by ProfiTrace you have several options These options can be useful for generating a Report because in some cases a statistic needs to be cleared e g after a Network Scan in ProfiCaptain e Reset station Select one address in the Live List and click Reset Station This resets ALL statistics for ONLY this station to O e Reset this statistic Select a statistic in the drop down box and click
139. pages with cable lengths and addresses Addresses clearly marked on the devices All GSD files are available in ProfiTrace Access to the PLC DCS configuration LILILILIEIEIEIEILILI ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 114 150 16 2 Checklist to create a reliable installation The following items can be implemented in and around your installation to make it more reliable L Repeater backbones with repeaters ProfiHubs isolation of problems L External powered termination removing adding devices L Reduce the baudrate improves signal quality L Increase the repeats retries increases success rate L Reduce the spur stub lines or use repeaters ProfiHubs improves signal quality L Cable as close as possible to ground decreases EMC sensitivity L Additional grounding points decreases EMC sensitivity L Activate the watchdog on all devices safety L Use fiber optic for long distances isolation of problems 16 3 How can I self test ProfiTrace and the ProfiCore Ultra Because ProfiTrace is a master busmonitor and oscilloscope in one it is very easy to do a self test Follow the steps below STEP 1 Remove all PROFIBUS cables from the ProfiCore Tap connector included STEP2 Start ProfiTrace Init ProfiCore STEP3 Set ProfiCaptain in Stop mode Setup master STEP 4 Auto detect the baudrate in ProfiTrace Auto detect baudrate STEP 5 Check the live list for 1 master addr
140. perty vaus O O O ES Titlename Address Address is alas 3 Ho Device Type nat sets Channel lt not set E S Segment 1 Measuring point 1 3 PLE 3 18 6 Slave 12 Slave 25 Slave Enter the station properties These properties will appear in the Report for convenient and detailed identification In fact all changes made to the Network Manager will improve the information that is printed in the Report 11 2 View Bar Graph To see the current or saved bar graph simply click on the tab Bar Graph next to the Properties tab Profil race for ProfiCore Ultra V2 7 c 2004 2012 PROCENTEC ProfiCore Ser Mr 2200000013 File Action Filter Trigger Toolbars View Report Settings Help PrafiTrace Scopew are Bar graph Topology Network Manager ProfiCaptain Heset Save Load NY Current Segment Properties Bargraph Scope Image Topology Segment 1 AB Diff stable voltage Sorted by Address Current Measuring point Measuring paint 1 9 0v 8 0V M Aubo add stations Stop Processing 7 0V Ely Segment 1 6 0V EE Measuring point 1 Cr EB 3 Master 5 0V EUD B Slave fC 12 Slave 4 0V E EL 28 Slave 3 0V 2 0V 1 0V 0 0v For further instructions about the use of the Bar Graph refer to paragraph 5 6 ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 11 3 View individual scope signals The Network Ma
141. port Fig 33 Shows a screenshot from an oscilloscope measurement in the report g ProfiTrace for ProfiCore Ultra 2 1 1 Ak 2004 2008 PROCENTEC PTK F ptd pearing Framestructure SD2 message Source address 36 Model Name Class81 80 WOODHEAD Destination address 2 Frametype Response message PROFIBUS DPV Message Data Exchange Con Res Fig 31 Start the report generation ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 54 150 g Print Preview ProfiTrace detailed network report 1 General Company Oil and Gas Company Network name Tank 4 Project details PLC with 5 devices TUE itk appo doy te rtc mer Peace meri rector Di Be comple tit 2 Used tools Senal number used ProfiCore Software version ProfiTrace 3 Network properties Transmission speed 1 5 Mbps Number of Masters 1 Number of slaves 5 C ycle time Min 1 47 ms Avg 391 ms Max 8 32 ms 4 Conclusion E Suggested to be approved X Restrictions Fig 32 First page of the report with conclusion and administration g Print Preview ProfiTrace detailed network report 13 Slave details continued Address 24 IdentNo 806A Manufacturer SIEMENS Model name ET 2008 IM151 Bytes VO length 1 inputs 1 outputs Signal voltage Min 5 07 V Max 6 18 V Last 6 14 V Diag
142. race for ProfiCore Ultra V2 4 c 2004 2009 PROCENTEC ProfiCore Ser Nr xxxxxx00002 81 x File Settings Help ProfiTrace ScopeWare Bar graph Topology Network Manager ProfiCaptain Load Project Save Project Zoom in Zoomout Draw Wire __ Setup Master Class 2 Commands DP V1 Class2 Watch Modify 1 0 6sD 4d Class 2 commands dialog General RE Set Change Slave Address Diagnostics Inputs amp Outputs Get Configuration Network scan nves 1 Switching oS E Start Scan Gateway PLCs Ident Systems Profibus PA Slave Info Modules Packeterrors 0 Click on Class 2 Commands to start the class 2 functions dialog Click on one of the tabs in the dialog to select a class 2 function 12 2 1 Network scan The Network scan is a very useful feature to detect all the available slave devices in the network After the scan has been started ProfiCaptain will send a Get Diagnostic message to all addresses The information from the responses of the available slave devices are listed in the dialog e Address e Ident Number e Model Name from the GSD file e Vendor Name from the GSD file e Implementation Type from the GSD file ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 88 150 If the GSD file of a detected device is not imported or the
143. red down up to adapt the new address A Lock feature Address change is available to block further address changes at the slave device use with caution ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC Class 2 commands dialog E x Set Change Slave Address Diagnostics Inputs amp Outputs Get Configuration Network scan Set Slave Addres Set Slave Address tab Current Address f 24 EE Iaa 3 Current and new address Lock Address Change Address p Change address Status field for info concerning the address change process Don ttick this unless you know how to reset the slave device Close Select the current and new address and click on Change Address to confirm 12 2 3 Read Input amp Read Output With the class 2 Read Input amp Read Output function ProfiCaptain reads out the last update of the input amp output data from a slave device Class 2 commands dialog x Set Change Slave Address Diagnostics Inputs amp Outputs Ger Conffigur Read O tab Read Inputs amp Outputs Address 32 z I Inputs Select an address Input data Output data Select an address and click on Read Input amp Outputs to update the 1 0 data ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 90 150 12 2 4 Get Configuration With the class 2 Get Configuration function ProfiCaptain reads the configuration fro
144. rform a network scan in the Class 2 commands menu A list of devices should appear with some GSD file information RE EE aes Verify the ProfiTrace Live List All slave devices now display a model name instead of a device address ASSIGNMENT 2 MULTI MASTER MESSAGE TRACE L Start a message recording in ProfiTrace and inspect the telegrams where the token is handed over between the active masters L Start a new message recording and enter the Offline mode in ProfiCaptain Try to locate the moment in the message trace where the token is lost ASSIGNMENT 3 DEVICES IN DATA EXCHANGE L Activate ProfiCaptain in the operate mode L Put all devices in Data Exchange with steal slave Verify this with ProfiTrace L Try to read write I O with Watch Modify I O ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 113 150 16 Tips and tricks This chapter contains some tips and tricks to make working with ProfiTrace a lot easier 16 1 Checklist to prepare your installation The following items can be implemented in and around your installation to simplify PROFIBUS troubleshooting At least 1 piggy back plug on every segment start of the cable Every segment has its own addressing range 10 19 20 29 etc Individual repeaters OLMs can be powered up down Individual devices can be powered up down PLC DCS at the beginning of the cable Diagnostics is enabled in the devices Installation drawing on 1 or 2
145. river Device Data Base for PROCENTEC Ultra Device gt Sa Saas Fig 55 CommDTM selection dialog After clicking OK the PCD server is launched automatically if it was not loaded already and the ProfiCore Ultra will initialize You will see the ProfiTrace and PCD icons appear in the system tray Initialising ProfiCore Verify that the ProfiCore Ultra was correctly initialized by looking at the yellow LED on the ProfiCore Ultra it should be on Make sure to set the correct bus parameters by right clicking the PROCENTEC DP V1 master and choose Parameters Enter the correct parameters or select Start to auto detect these Then click OK Next choose the icon Connect from the top menu PACTWare teleka File Edit View Projet Device Extras Window Help D guala Qe C230 83x28 Project 3 ij PROCENTEC DP V1 Master Parameter Device tag PEE PROCENTEC DP V Master ADBENIE B5 HOST PC 1 X M Communication 90008 4 PROCENTEC DP V1 Master PROCENTEC DP V1 Master E cal LE Bus Parameter x bog acing dy Baud Rate 11 Use Standard Bus Parameters After you have correctly applied these steps the ProfiCore Ultra is now a DP V1 master and ready for communication to field devices For a detailed walk through refer to the Download section of the PROCENTEC website for a comprehensive Quick Start for PACTware and FieldCare ProfiTrace 2 9 2 User Manual
146. s a synonym for the RS485 based deployments within factory automation ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 133 150 PROFIBUS PA Reflection Repeat Repeater Retry SAP SDA SDN Spur line SRD LOW HIGH SSAP Stub line ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC Acronym for PROFIBUS for Process Automation This is an application profile based on PROFIBUS DP independent from the physical profiles RS485 Fiber Optics MBP The requirements of continuous manufacturing are covered within the application profile PA Devices and the extension MBP to the physical profiles Part of the original signal that is transmitted back along the cable It corrupts the original signal When a station does not respond within the specified Slot time the master will repeat its message to the slave The maximum number of r epeats can be set in the bus parameters of the master After the last repeat the station is assumed to be lost Active physical layer device that receives and retransmits all signals over a different port to increase the distance and number of devices for which signals can be correctly transferred for a given medium See Repeat Service Access Point This is a defined code command that tells the slave what data is to be transmitted or which function is to be performed There are always 2 SAPSs in a message SSAP Source Service Access Point
147. s blinking This station is active as a slave but also the Static Diag bit is active With this static bit the device wants to indicate that no I O is updated at this moment or that I O or other measurement value is not yet ready to be transferred startup phase of a DP DP V1 slave ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 40 150 Upper left and right corner of cell is blinking Both the Ex Diag bit and the Static Diag bit are active see description above In these situations click on the slave and check the Info Panel for more diagnostic information It is highly recommended to import the GSD file because you get more information about the type and description of the diagnostics 5 3 2 Statistics Click and go The statistics matrix is the most powerful feature of the analyzer This field can really indicate what the condition of the installation is It displays all the important information that a user especially a maintenance technician is really interested in Because of this feature the user does not have to inspect messages or do difficult operations to ensure the quality of the installation Syncs The Syncs not to be confused with the Sync mode of a DP slave holding the outputs is a statistic that indicates the times a master sends a message to a station for what it has determined to be the first message to that station As soon as the station starts answering the master does not
148. should be ON if the laptop PC is powered It depends on the installation how we connect the ProfiCore to the installation On DP RS 485 installations we use the Tap Connector see chapter 19 On PA MBP installations we use the PA Probe 1 4 ach tar ta tha Draf 5 1 1 Attach the Tap Connector to the ProfiCore in LA Attach the straight plug of the Tap Connector to the DB9 connector of the ProfiCore see Fig 9 Fig 9 Attaching the Tap Connector to the ProfiCore Please check if the termination resistor on the Tap Connector is OFF In regular situations the termination on the Tap Connector is NOT required v5 0 0 27 January 2015 PROCENTEC c C e ProfiTrz E42 D E Atta a aanhina tha SARL Aara ta tha DD pei ARAH 3 1 2 Attachning tne FFrOTILOrE to tne Dr Installation Attach the 90 degrees plug of the Tap Connector on top of a piggy back connector of the PROFIBUS DP installation see Fig 10 Fig 10 Attaching the ProfiCore to a DP installation D Tighten the screws to avoid the Tap Connector from accidently detaching of the piggy back plug ProfiTrace 9 9 9 E PE Manial v5 00 27 lanuarv 2 015 LA DRAC ENTEC Protilrace 2 9 2 User Manual v5 0 0 2 January 2015 PROCENTEC 5 1 3 Attaching the PA Probe to the ProfiCore Attach the DB9 connector of the PA Probe to the DB9 connector of the ProfiCore see Fig 11 It is recommended to prepare s
149. sion connector ProfiCore Ultra has an expansion connector RJ 45 which can be used for all kinds of additional functionality ProfiTrace 2 uses the expansion connector to trigger an additional external oscilloscope ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 14 150 3 Software installation instructions Windows 7 This chapter describes the installation for ProfiTrace 2 and the ProfiCore Ultra drivers It is assumed that you have a basic knowledge of Windows operating systems All example and dialogs are based on a US UK based windows installation and may differ slightly based on upgrades updates and enhancements Please use the screenshots in conjunction with the description in order to press the appropriate buttons and other user interface items It is possible to install ProfiTrace 2 next to ProfiTrace 1 they are both using another default installation directory and the drivers are different You can even run both applications at the same time 3 1 Installation procedure The installation of ProfiTrace has to be done with the following procedure Preparations prior to installation Installing the ProfiCore Ultra driver Installing ProfiTrace Connecting the ProfiCore Ultra to the USB port Installing GSD files in ProfiTrace and ProfiCaptain a 2 IT Setting colour preferences 3 2 Prior to installation Prior to installation follow the steps below L Make sure you always use the lat
150. ssssscccccesseccccseesececccseecceseeaseceeseueseeeesssaseecessseueeessuaasecessuansees 79 11 3 1 User Scope Ma E aesssusises nr nEOT V abc s uoPe Uo vba Festus escapade oo Ru eid EVER ete 79 TVA TODO OSV SO a D ee Do e 79 11 5 Saving loading and TeSeEtiIg usssesessesieskteesrtudrens venue curtastGvdiseMt sus educar ones QUE UE nenrmerte annee 79 11 6 Creating a new measuring point eeeeeeeeeeee eene enne enhn nnne nnne rhet estas sh esst estas sees s testas 80 1LZ Creatine anew SeBImelitaseowe d vevxdss dx UT eYYX Ya EN LEFnVE FE ev TIER FUXXA scene finesse creer COR SU E AOI FEY dU 81 11 8 Rearranging segments ccscccssccssccessccssccesscessccseceseceseesaeecessceseesaesseeeceaeesaesseusceaecsaessesseeaeesaesees 82 a a a nd rere 84 121 Setting up tne DP Master ae ao a a et 84 12 1 1 Manual busparameter setting uuscexom eresterr eui bRt XP EU erra REP rx ORE SER GIINCU s EMI CRF OCPUTKRUP EU rU FU bata cdd Teu 85 12 1 2 Automatic busparameter detection sise 86 12 1 3 Actduate Ihe DP MASTE ae een a ta or on 87 12 2 Class 2 DP VO functions ccccccssesseccssessecscssssscesccssssecucesssssescessssecscesssssencesssssencesssssessesssscensesssss 88 12 2 1 Network SCO RE ee en ee ae nee a 88 Se SlIVE Addi GS RER RE SR 89 12 2 3 Read Input amp Read Output ii EEEE NEE EE 90 12 24 GET COMMPUPALION MU Um m 91 DP Pe DAS SEI CS el 91 12 3 Configuring slave TIO VICOS ra da
151. t on the Ex zone At the end of the cable it should be higher than the lowest dropout Voltage of the PA instruments normally between 9 to 11 V The AC signals should be between 750 mV to 1 V with a proper terminated network When the amplitude is higher it could be that termination is missing The noise level should be less than 150 mV preferably less than 75 mV The bias should be less than 50 mV difference between top and bottom signal EM ProfiTrace for ProfiCore Ultra V2 2 c 2004 2008 PROCENTEC ProfiCore Ser Nr xxxxx00002 1 1x File Action Filter Trigger Toolbars View Report Settings Help ProfiTrace ScopeWare Bar graph Topology Network Manager ProfiCaptain Mode PA AC amp DC AC scale 125 mV Div DC scale 2v Div gt Time scale 25 mSec er M SD1 M SD2 M SD4 v Short ck Address 3 Trigger Message Trigger Star of response Freeze JV Cursors active Trigger delay Reset trigger delay Cursor 1 olt Cursors 13 64 mSec 500m uen RS E M Bg a ee S 12 65 mSec M fI TY TT TT mm T TT TRI TT Tm TR 26 29 mSec 3130308 6 m 38 Hz OT TEMPE ET TT P eni iuf gt vu arp parL a een ipe il e I 821 71 Bits i 125m LL Fa REET S i mA Xem J M auiii tp MINIS 0 01 V 1312V ev Noise level 1311V s 150 mV i 0 34 V 0 41 V 0 74 V x AC signals 750 mV 1000 mV DC Voltage 12V
152. t resistance 600 kOhm Input capacitance 1nF ProfiTrace version Works with ProfiTrace V2 2 1 and higher ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 119 150 19 Technical data Tap Connector The Tap Connector is a small cable to connect the ProfiCore to a PROFIBUS DP network It has been designed NOT to cause network disturbances due to spur lines A perfect vertical position for the ProfiCore is obtained that does not overpressure the piggy back plug which is attached to the DP network The cable is of the flexible type so you can move it to all directions ProfiTrace2 PROFIBUS Installation D Please check if the termination resistor on the Tap Connector is OFF In regular situations the termination on the Tap Connector is NOT required ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 120 150 20 Hotkeys General F1 Messages F2 F3 FA F5 F6 F7 F8 Help Toggle between RAW frames and decoded frames Switch the Timestamp column between Tbit sec ms us date and time Switch the Idle Time and Deltatime column between Tbit sec ms us date and time Toggle between Hex data and Decimal data Toggle between normal view and filtered view Jump to next message with the same source and destination address Jump to previous message with the same source and destination address ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC
153. tatistic should be the same for all DP slaves since the DP master generally handles all slaves it has been setup for in every token cycle Slowest Data Exchange interval msec slowest cycle time This statistic shows the slowest measured time in milliseconds between 2 Data Exchange cycles to the same DP slave Please note that when a DP slave has become temporarily offline and when coming back on the bus this statistic should be reset in order to show again the latest status Fastest Data Exchange interval msec fastest cycle time This statistic shows the fastest measured time in milliseconds between 2 Data Exchange cycles to the same DP slave Slowest Fastest Data Exchange interval msec slowest fastest cycle time This statistic shows both the slowest and fastest measured time in milliseconds between 2 Data Exchange cycles to the same DP slave Data Exchange frequency Hz This statistic shows the same as the Data Exchange interval statistic but now in Hz Data Exchanges per second Input size This statistic shows the last detected Data Exchange input size Output size This statistic shows the last detected Data Exchange output size Input Output size This statistic shows both the input amp output size based on the last detected Data Exchange output size Diagnostic msg req by master This statistic shows the number of messages a master has sent a Get Diagnostics message to a DP slave Diagnostic msg res from
154. te the remaining stations at the other end in this case only station 28 Right click the station and select Delete station or hit the Delete key on your keyboard ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC In the next segment you can delete either station 3 or 6 and make one of them an alias m ProfiTrace for ProfiCore Ultra V2 7 c 2004 2012 PROCENTEC ProfiCore Ser Nr 1000000013 File Action Filter Trigger Toolbars View Report Settings Help ProfiTrace Scopeware Bar graph Topology Network Manager ProfiCaptain Reset Save Load Current Segment Properties Bargraph Scope Image Topology Mixer Floor 2 A Current Measuring point afer repeat BR Propert vaus O O QE After repeater L 2 aue Titlename Repeater B1 i Show list Address b M Auto add stations Stop Processing Address is alias Device Type Standard Repeater EPA Premier Floor 1 Channel Secondary j SEa Start of segment at master 3 E EEG 3 Master ED 6 Slave a Et 127 Repeater B1 H S Mixer Floor 2 E After repeater E EO 6 Repeater B1 E 12 Slave cer EY 28 Slave When this is done you are ready to generate a Report Refer to paragraph 5 10 ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 12 ProfiCaptain ProfiCaptain is a PROFIBUS DP class 1 and 2 master that has been designed for applications like I O tests
155. tely The loop resistance causes residue amplitude that could be enough for the devices to remain in Data Exchange Make sure you know the last 2 devices on the segment and inspect both their signals By means of the reflections you can easily track the cable towards the problem The last 2 devices will also indicate the worst case reflections ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 9 4 Short circuit between B and Shield A short circuit between B and Shield same as A and Shield will show a small deviation in the signal and is difficult to diagnose see Fig 40 An easier method is to switch ScopeWare to the A amp B mode In this mode you will see the individual A and B signal Her you can clearly see an abnormality see Fig 41 5 3 ProfiTrace for ProfiCore Ultra V2 5 c 2004 2010 PROCENTEC ProfiCore Ser Nr xxxxx00001 88 0 nSec 531 6nSec 163 3 m 1881132 Hz 0 80 Bits 222V 281V 483V TE C PUTES REP s Cursor 1 61 96nSec Cursor 2 88 0 nSec Ser E Ca ri 1 Distance 833m R quer y So H Bit Factor 080 Bits mm Volt Cursors Cursor 1 1 35 VY Cursor 2 4 81 Y CursorDiff amp 16V Volt Cursors Cursor1 1 32 V Cursor 2 gay CursorDiff 6 25 V I 32 Fig 41 Short circuit B Shield A amp B ProfiTrace
156. ter detection and proceed to paragraph 12 1 2 Bus parameters configuration dialog P Ua Auto detect Bus Parameters Stop detecting Bus Parameters Set all the required items to the correct values and click OK to confirm The master is still NOT active on the bus This has to be done in the next dialog ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 85 150 12 1 2 Automatic busparameter detection This paragraph describes the automatic busparameter detection This mechanism is very powerful because the chance that ProfiCaptain corrupts the data communication in a running multi master installation is extremely small Bus parameters configuration dialog Stop detecting Bus Parameters 15Mbps x p po s b s rs on Sf it 10E After clicking on Auto detect busparameters ProfiCaptain will display the detected busparameters and advise a free available master address It also fills a simple Live List with devices that show bus activity From this point the user has also influence to alter the detected settings Click OK to confirm The master is still NOT active on the bus This has to be done in the next dialog ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 86 150 12 1 3 Activate the DP master The last step is to enable the master Master system configuration ee me es Click Operat
157. the licenses on multiple PCs The ProfiCore Ultra you utilize will determine the functionality of ProfiTrace Fig 6 illustrates how licenses can be stored on multiple PCs File Edit View Favorites Tools Help Size T Date Modified Bmmxe23 mj bmp File Folder 09 03 09 17 01 8 OR File Folder 09 03 09 17 01 amp C dat fies File Folder 09 03 09 17 01 Oe experts File Folder 09 03 09 17 01 3 fiter settings Security Catalog 18 06 08 12 32 eo fj default v2 3 0 cfg CFG File 12 03 09 17 05 gt osdibtmo S FTD2xx dil 1 10 10 03 14 3 O inspect_files 2 lang deutsch pin C network data B lang english pln C ProfiCore Ultra USB Driver f langsel cfg C search settings S pcapt2 dil dii amp ProfiCoreUltra2 05045 pld amp ProfiCoreUltra2 05182 pld PLD File 28 01 08 16 46 8 ProfiCoreUltra2 05186 pld PLD File 28 01 08 16 46 amp ProfiCoreUltra2 05188 pld PLD File 28 01 08 16 43 amp ProfiCoreUltra2 05189 pld PLD File 28 01 08 16 45 8 ProfiCoreUltra2 05377 pld PLD File 09 04 08 10 57 amp ProfiCoreUltra2 05699 pld PLD File 28 08 08 08 51 ffi ProfiTrace2 exe Application 09 03 09 12 00 S ptutilsvO 25 dll Application Extension 04 12 08 16 03 fj settings V2 3 0 cfg CFG File 12 03 09 18 04 5 USB1 0 supp dll Application Extension 05 12 07 14 02 3 wdapi901 dll Application Extension 17 06 07 11 46 a 23 objects Diskfree spaces 62 3 RAMS 3 My Computer Z
158. this refer to paragraph 5 3 2 1 ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 66 150 8 Wizard The Wizards in ProfiTrace 2 can start an automated and assisted series of events to be executed by the software or user They help you to create useful Reports or retrieve and gather more information of the PROFIBUS network which can later be used for troubleshooting 8 1 Accessing the Wizard features There are two methods to access the Wizard selection box You can start ProfiTrace 2 in Wizard mode from the shortcut in the Start Menu or if ProfiTrace 2 is already running click the Wizard button wwunmnogra view mepu k Cu y gt p ProfiTrace V2 8 D vare Bar graph Topology Network Manager ProfiCaptain Driver Install for ProfiCore Ultra G ps z z 3 J a t viewer Setup record trigger Start message recording Stop message reco iu End User License ix m lar z ore Ultra Auto detect baudrate Set baudrate Wi L omputer d lessage recording X Record to file X Set record ProfiTrace V2 9 Wizard Mode Control Panel V Live list E Messages S Messages with view filter applied QD Station statistics vi HS 126 Reset selected station Info Panel data Diagnostics Aut ProfiTrace V2 9 Uninstall ProfiTrace V2 9 ProfiTrace V2 9 Wizard Mode OPC redistributables n ProfiTrace help amp manuals Default
159. tings menu In the next dialog you can add tags see Fig 50 All basic tags are already available Live List and Statistics When you do not require additional tags you do not have to enter this dialog and can you directly proceed to the server settings The OPC tags are locations in the 1 0 data of the devices offset O is the first location Be careful with too many tags The quantity of tags can slow down your system especially when you want to run multiple applications at the same time To solve this you can filter tags in the client you are using You can save your data in a PTO file which is used later during the setup of the OPC server ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 99 150 TagName DataType AccessRights Switch Unsigneda8 VT UI1 Read Device Address 32 E General v Onlinestatus Baudrate E Statistic H Syncs H Retries H Retriesworst StationLost IllegalResponses 5 DXIntervalLast H DXIntervalSlowest H DXIntervalFastest DXFrequencyLast DXNumInputs i DXRateOfInputChangeLast H DXRateOfInputChangeFastest DXNumOutputs DXRateOfOutputChangeLast DXRateOfOutputChangeFastest i DiagReqCount i DiagResCount DiagResCountWhileInDX DiagSizeLast i DiagSizeLargest El LiveList Status v ddr000 Addr001 Addr002 Fig 50 Adding OPC tags 13 3 Activating the OPC server
160. ts Check if the Syncs have stopped ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 110 150 15 5 Data inspection ASSIGNMENT 1 INTRODUCTION L Display the input and output data of a couple of devices 15 6 Oscilloscope ASSIGNMENT 1 INTRODUCTION L Click on ScopeWare and check if the oscilloscope runs L Trigger on each device including the master s by clicking twice on the Live List At the same time select an appropriate time base in which the end of the master message is seen as well ASSIGNMENT 2 POWERED TERMINATION L Inspect the Voltage level during the quiet time between 2 messages Voltage level E Remove the power from one of the termination and inspect the Voltage level during the quiet time between 2 messages Voltage level E If possible also remove the power of the 2 termination and inspect the Voltage level during the quiet time between 2 messages Voltage level Fix all faults ASSIGNMENT 3 TERMINATION MISSING L Remove a termination L Try to find the distance to the problem by triggering on the last 2 devices on the segment Fix all faults ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 111 150 ASSIGNMENT 4 SHORT CIRCUIT L Create a short circuit between A and B at the end of the cable L Try to find the distance to the problem by triggering on the last 2 devices on the segment Fix all faults 15 7 Bargraph
161. tware for He ProfiCore Ultra Device Click Finish to close the wizard Click Finish to close the install shield When the ProfiCore Ultra is connected to another USB port the driver installation process will start again only once for every port or ProfiCore Ultra ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 21 150 3 Directories After installation ProfiTrace has created the following directory structure Directory Purpose Requires backup App Program setting language and license files Dat_files Saved projects Yes Exports Exported data Yes Filter_settings Settings for data filtering Yes Gsd GSD files for ProfiTrace and Yes ProfiCaptain Gsdlibtmp Catalogue of scanned GSD files Inspect_files Settings of the data inspector in Yes ProfiTrace Network data Saved information from the network Yes manager WProficore ultra usb driver USB drivers for the ProfiCore Ultra Search settings Message search settings Yes C ProgramData procentec proficoreultra License files Yes ProfiTrace v2 7 and up Fig 3 illustrates the ProfiTrace directory structure or gt Computer Local Disk C Program Files x86 ProfiTrace V2 9 gt Ww P Organize Include in library Share with Burn New folder Favorites Name j Date modified Type Size WE Desktop Jj App 18 11 2013 9 46 File folder Jg Downloads dat files 5 11 2013 16 18 File fo
162. you already have a license for ProfiTrace and you wish to explore the possibilities of ProfiCaptain or ScopeWare for example you can request a trial license for free The trial license is valid for two weeks Request a trial license by filling in this form on our website http www procentec com trial The request will be processed as soon as possible but can take up to three days When we have generated the trial license you will receive an email from us 4 6 Activating a Trial License To activate the trial license please follow these steps ProfiTrace 2 9 2 User Manual v5 0 0 27 January 2015 PROCENTEC 31 150 STEP 1 Look in the Common ProfiCore directory for the license of the ProfiCore Ultra for which you requested a trial license Then rename the license to something else with a tmp prefix for example see Fout Verwijzingsbron niet gevonden The directories where you an find your license are usually e Windows XP C Documents and Settings All Users Application Data procentec proficoreultra e Windows 7 C ProgramData procentec proficoreultra e The App directory of your ProfiTrace installation QU d Local Disk C ProgramData procentec proficoreultra v 4 Search proficoreultra Organize Include in library Share with Burn New folder v HH e A Favorites a Name j Date modified Type Size BE Desktop T Ennio 7 11 2012 13 51 PLD File 1KB Downloads 47 Dropbox t Recent
Download Pdf Manuals