Home
mixing consoles USER/SERVICE MANUAL
Contents
1. DN mixing consoles TIMER USER SERVICE MANUAL D amp R Electronica Weesp b v rijnkade 15B 1382 GS WEESP The Netherlands Phone 31 294 418 014 Fax 31 294 416 987 website www d r nl E mail info d r nl O 6 O DR ODE ES EN DE En REET one TIMER _ UPIDOWN O ze _ O INTRO O a Poweron fm Synchronisation Mode po Display the date buffer la or ee ai l Edit Go to editmode to change the date Program Count Down PCD IEditmode Edit Display Mode Intro Edit Reset Start Stop Mode Go to edit mode to change the actual time gen press Short press View the buffer clock buffer Toggle display between tens of seconds or hours Change timermode up down down up en intro Save actual buffer and set intro mode Go to editmode to change timerbuffer rye press Short press View the timerbuffer L tran Restore the timerbuffer and stop count Start and stop counting L Displays the date on which the out switches G to editmode to change PCD date Edit Mode Intro Extern Display Edit Reset S
2. 64K 100ns Ic 74HC573 octal D latch Ic 7805 TO220 SGS volt reg Ic 80C552 8 bit micro comptr Ic PCF8573P clock calendar Ic voet 16 pins vork contact Ic voet 20 pins vork contact Ic voet 28 pins vork contact Ic voet 68 pins PLCC Socket Jack chassis break Kartelring M 3 buitenvertan Koelprof KL 169 SW TO 220 Kristal 32 768 KHz 1 27 S423 Kristal 6 00 MHz Led Display 10mm c anode red Moer M 3 Print Timer 9 5 e Printtrafo 3 2VA 2x8v 2x115v Relais D1C121000 1xchnge minid Schakelaar ST1044 gr momentary Schakelaar ST1044 zw momentary Taptite M3x10 bolkoppozidr zw Transistor BC 327 25 pnp Transistor BC 337 25 tape npn Trimmer 65 pF 5 5 gt 65pF Weerstand 2k2 5 1 4W Weerstand 3k3 5 1 4W Weerstand 4k7 5 1 4W Weerstand 10E 5 1 4W Weerstand 10k 5 1 4W Weerstand 100E 5 1 4W Weerstand 100K 5 1 4W Weerstand 560E 5 1 4W Zekering 160mA slow 5x20mm Zekeringhouder print kap Adereindhuls ong 0 75mm L 6 Bandkabel 20p R 1 27 Connector bandkabel female 16p Doos Randapparatuur 9 5 Dubbelzijdig plakband 12mm dun Front 9 5 Timer a Isolatiebus TO 3 NYLON Isolatieplaat 9 5 randapp PVC Jack moer Kabelschoen boutgat M3 rood Quantity Unit 1 0000 st 1 0000 st 1 0000 st 2 0000 st 16 0000 st 1 0000 st 9 0000 st 1 0000 st 1 0000 st 1 0000 st 2 0000 st 2 0000 st 1 0000 st 2 0000 st 1 0000 st 1 0000 st 1 0000 st 1 0000 st 2 0000 st 1 0
3. 000 st 1 0000 st 4 0000 st 1 0000 st 1 0000 st 1 0000 st 1 0000 st 6 0000 st 1 0000 st 1 0000 st 1 0000 st 1 0000 st 2 0000 st 6 0000 st 1 0000 st 6 0000 st 3 0000 st 1 0000 st 6 0000 st 2 0000 st 8 0000 st 1 0000 st 3 0000 st 2 0000 st 10 0000 st 15 0000 st 1 0000 st 1 0000 st 2 0000 st 30 0000 cm 4 0000 st 1 0000 st 20 0000 cm 1 0000 st 4 0000 st 1 0000 st 4 0000 st 1 0000 st 10700625 10150093 10250386 10250387 10700610 10600498 10700656 10100656 20851140 10800956 10800429 10800275 10800421 10700787 10700790 10700788 10700691 Kartelring M 3 buitenvertan Kast 9 5 1HE version D Led 3mm green SLR 03A210 020 Led 3mm red SLR 03A510 020 Moer M 3 Netsnoer 3 aders euroconnector Plakvoet bouton zwart 10x10 Plexiglas Timer Print bestukt Timer Schuimblok 9 5 Sticker CE Sticker OUT IN Sticker WARNING rood Taptite M3x6 bolkoppozidr zwrt Taptite M3x6 verzkop pozidr zw Taptite M3x8 verzkop pozidr zw Trekontlasting voeding rond 1 0000 st 1 0000 st 3 0000 st 4 0000 st 1 0000 st 1 0000 st 4 0000 st 1 0000 st 1 0000 st 2 0000 st 1 0000 st 1 0000 st 1 0000 st 1 0000 st 8 0000 st 8 0000 st 1 0000 st
4. f the EMC Directive 89 336 EEC 1989 as amended by the CE Marking Directive 93 68 EEC 1993 D amp R Electronica Weesp b v Rijnkade 15 B 1382 GS WEESP The Netherlands President of Engineering The product is tested in a normal users environment BILL OF MATERIAL D amp R Electronica Weesp BV SERVICE MANUAL 60898540 Timer 9 5 Articlecode Description H H 10950470 10950471 10250345 10400217 10401241 10600180 10250342 10400284 10400292 10400294 10600521 10600520 10250026 10250033 10250291 10250036 10250200 10600396 10600398 10600401 10600403 10600432 10700625 10720662 10250397 10250395 10250120 10700610 10201140 10950584 10550001 10550009 10550008 10700616 10250333 10250332 10400320 10350733 10350735 10350737 10350705 10350741 10350717 10350753 10350726 10990693 10990675 10700076 10650448 10600466 10800924 10700975 10101145 10500962 10500084 10600436 10600007 Batterij 3V lithium knoopcel Batterij houder knoopcel Brugcel B80C1000 rond Condensator ker 22p R2 5 Condensator ker 100nF 50V R5 T Connector netaanslklem 2p 5mm Diode 1N4148 signaal Elco 10uF 40V radiaal R5 0 Elco 100uF 25V radiaal R5 0 Elco 470uF 25V radiaal R5 0 Header haaks 16p box R 2 54 Header recht 16p box R 2 54 Ic 27C512 10 EPROM
5. ion exactly if you are not located more than 1000km away from this transmitter All summer winter time adjustments will be done automatically and time will be accurate within 1 sec over a timespan of 1 000 000 year The small connector block on the pcb should be connected in the following way to the Timerunit Frankfurt i EN nn Use a stereo 1 4 jackplug and connect the me receiver via regular 2 wire microphone cable to the Timer unit in the following way L as gee ROn 1 Sleeve ground Resides 2 Tip of jack stand Antenne Metall 3 Not connected _ _min 20mm F P 4 Ring of jackplug pull up Widerstond If you have intentions to make a small cabinet folls erforderlich around the receiver do not use metal housing R gt UB mA but a plastic case will do the job 1 Masse 2 Betriebsspannung 15 15V eas 3 DCF pecs a If you have any questions relating to this item 4 DCF Ausgang invertiert do not hsitate to call our ervice department of your dealer Ausg nge 3 und 4 offener Kollektor npn max 30V 1mA DECLARATION OF CONFORMITY Manufacturers Name D amp R Electronica Weesp b v Manufacturers Address Rijnkade 15B 1382 GS Weesp The Netherlands declares that the product TIMER series conforms to the following product specifications EMC NEN EN 55103 1 1995 NEN EN 55103 2 1995 NEN EN 55013 1 1994 Supplementary Information The products herewith complies with the requirements o
6. ived properly by the internal circuitry a blinking point shall be seen positioned after the Sec indication in a 1 sec sequence EDIT FUNCTION The edit function acts like a separated mode For every mode the timer has a buffer Due to a edit you can change the edit buffer for this mode So in the timermode you don t affect the clock or Program Count Down PCD buffer When you leave the editmode the buffer is saved and activated With a short push on the edit button you can see the actual value of the buffer of the actual mode D amp R Electronica Weesp BV rijnkade 15B 1382 GS WEESP The Netherlands Phone 31 294 418 014 Fax 31 294 416 987 Installing battery back up of the Timer To keep continously clock information when the timer is disconnected from AC power a lithium cell battery needs to be installed It needs to be a 3 volt button type cell for instance a Varta CR 2025 or equivalent INSTALLATION 1 Remove the unit from the mains 2 Remove the cover by unscrewing the bolts on the left and right side 3 Insert cell with upwards 4 Place cover again and mount all sides together 5 Power up the unit and your timer will hold all its clock information during power down DCF RECEIVER CONNECTIONS In the Europe area you can have an improved accuracy of the timer by connection a DCF receiver to the timer DCF input jack The DCF pulses are transmitted from Mainflingen Frankfurt area and keep your time informat
7. ou can select this mode by hitting the mode key The LED s on the front indicate in which mode the timer operates Count up Countdown Count down up or Count intro The start value of the timer may be entered by using the edit function For the Count intro mode a special key is made When you start the timer e g count up and you press the intro key the actual bufferstate is grabbed and put into the edit buffer With a reset the edit buffer is used for restart The start stop button is used to start and stop the timer In the timermode you can also use the Airmix input This input receives a faderstart faderstop and or areset When the signal on the tip is high the timer is active or else it doesn t count When a pulse is generated on the ring the buffervalue is stored in the timer You can easily time intro s and jingles during this setup PROGRAM COUNT DOWN MODE The PCD mode acts like the countdown mode When the counter passes zero a relay connects the ring and tip of the out jack In the editmode you can give an end time e g end of your broadcast The timer calculates the remaining time This mode calculates only in minutes and hours not seconds This is because all programs are ending on full minutes DCF INPUT The DCF input is used for synchronising the internal clock to an external DCF clock This function is optional and only available for use in Northern Europe If the data from the external DCF clock receiver is rece
8. tart Stop Go to editmode to determine PCD time Long press ES press View the PCD time out of the buffer ncrement the digit above Increment the digit above Increment the digit above Increment the digit above Increment the digit above increment the digit above po Save the buffer and go back This figure shows a short list of all functions The boxes in the centre show the keys to change the functions in the active mode The result of this activity is written in the box on the right side of the page To toggle between operating modes push the upper right button See the other side for a functional description FUNCTIONAL DESCRIPTION OF TIMER MODULE The timer may operate in three modes The clockmode Timermode and Program count down mode in short called PCD The upper right button selects the operating mode CLOCK MODE The first mode is the Clockmode After power up and synchronising this mode is entered This mode displays the actual time when this is not right you must enter the edit mode by pressing the edit key for about one second A short push on this key displays the buffer When the time has been edited you can press the start stop button as soon as the edited time is actual Now the timer continues with the new time TIMER MODE The Timer mode is the second mode In this mode you can select several counters for specific timing Y
Download Pdf Manuals
Related Search
Related Contents
SWITEL TE 12 Gebrauchsanleitung Instruction manual Mode d`emploi Handleiding Gigabyte GA-H61M-S2P-B3 motherboard TrafficShield Installation and Configuration Manual RIKKE-MATHILDA microassemblers and simulators on Product Guide instructions generales concernant les ballons habites Installazione driver e software Kenroy Home 61018 Installation Guide Copyright © All rights reserved.