Home

Operators manual optris PI NetBox - E2013-01-A

image

Contents

1. optris PI NetBox E2013 01 A Ethernet Direct Communication Please connect your imager with the supplied USB connection cable with the PI NetBox Please connect your PC with an Ethernet cable with the NetBox Now connect the power supply to the NetBox and to the mains The NetBox will start to boot the system and should be ready to use after 2 3 minutes You can check the status with the LEDs At proper functioning now L1 and L5 should light up PC 8 48 V DC PiConnect PiConnect Server Ethernet direct connection point to point connection PI NetBox powered via power supply If you use a PoE injector the power supply for the NetBox is not needed In this case please connect the PoE injector as shown in the drawing below At proper functioning now L1 L2 and L5 should light up Follow the steps according chapter Connection to a Network Device Point to Point Connection optris PI NetBox E2013 01 A 10 PC PiConnect PoE Power over Ethernet PoE PiConnect Server Damn Ethernet direct connection point to point connection Pl NetBox powered via PoE injector Ethernet Network Communication Please connect your imager with the supplied USB connection cable with the PI NetBox Please connect the Ethernet connection of the NetBox with a network or internet via a router e g Now connect the power supply to the NetBox and to the mains The NetBox will start to boot the system and should be ready to use after
2. 24 VDC T Vou adapter cable Ethernet cable USB Rescue stick 2 GB Rail mount adapter Operators manual optris PI NetBox E2013 01 A Scope of Supply Lightweight version PI NetBox incl micro SDHC card 8 GB Power supply 100 240 VAC 24 VDC Power cable with open ends for direct connection to a Lithium battery Video adapter cable Ethernet cable USB Rescue stick 2 GB Operators manual Maintenance PLEASE NOTE Never use cleaning compounds which contain solvents The housing of the NetBox can be cleaned with a soft Take care that no moisture infiltrates into humid tissue moistened with water or a water based the housing cleaner Cautions Take care that no foreign substances penetrate into the venting slots of the PI NetBox In case of problems or questions which may arise when you use the NetBox please contact our service department Please use only the threads in the housing or the supplied rail mount adapter for mechanical installation of the PI NetBox Avoid mechanical violence this may destroy the system expiry of warranty optris PI NetBox E2013 01 A Technical Data General Specifications Operating temperature Storage temperature Relative humidity Material housing Dimensions Weight Vibration Shock Operating system Electrical Specifications Power supply Power consumption Cooling Board Processor ROM RAM Ports Extensions Additional functi
3. 2 3 minutes You can check the status with the LEDs At proper functioning now L1 and L5 should light up If you use a PoE injector the power supply for the NetBox is not needed In this case please connect the PoE injector as shown in the drawing below At proper functioning now L1 L2 and L5 should light up Follow the steps according chapter Connection to a Network Device Ethernet network communication optris PI NetBox E2013 01 A 11 Network Internet a WE PC PiConnect PiConnect Server we mP S ee Ethernet network connection PI NetBox powered via power supply Network Internet Power over Ethernet PoE B PlConnect PiConnect Server n E Ethernet network connection PI NetBox powered via PoE injector optris PI NetBox E2013 01 A 12 Stand alone Operation Analog OUT IN Digital IN PI Process VGA Video Interface Monitor 8 48 V DC eN nn USB Process HEINE USB Keyboard Mouse optris PI NetBox E2013 01 A 13 Connection to a Network Device Point to Point Connection The communication with the NetBox is done via the TCP IP protocol Transmission Control Protocol Internet Protocol The NetBox can get its IP address Internet Protocol address either from a DHCP i server or it can work with a fixed IP address On a direct connection to a PC both the NetBox as well as the PC must use a fixed IP address because no DHCP server is available here
4. PRO 1000 MT Network Connection settings below This connection uses the following items User configured JM Client for Microsoft Networks da QoS Packet Scheduler da File and Printer Sharing for Microsoft Networks amp Intemet Protocol Version 6 TCP IPv6 amp Link Layer Topology Discovery Mapper 1 0 Driver Link Layer Topology Discovery Responder Sent Ar Received Bytes 96 057 29 998 Description Transmission Control Protocol Intemet Protocol The default wide area network protocol that provides communication 8 5 isabl z across diverse interconnected networks Validate settings if changed upon exit cose J Canel 5 Please open now the register Alternate Configuration and activate the checkbox User configured 6 Now you can enter a user defined IP address for your PC Please take care that the network part of the address has to be identical with the network part of the IP address of the NetBox thus 192 168 0 For the host part you have to use an address which is different from the one of the NetBox 100 so you may use 1 for example optris PI NetBox E2013 01 A 15 Internet Protocol Version 4 TCP IPv4 Properties General Alternate Configuration If this computer is used on more than one network enter the alternate IP settings below Autom
5. The NetBox is using in this case the IP address 168 0 100 On your PC you have to do the following settings once depending on the operating system the procedure can differ from the here shown the following description refers to a Windows 7 system 1 Go to System controls open Network and Sharing Center 2 If you have an existing connection to a network company network e g you should see the following information View your basic network information and set up connections A See full mag i your computer your current network Internet If your PC is not connected to any network please go to Change adapter settings after you opened the Network and Sharing Center View your active networks Je your current network Access type Local and Internet Domain network Connections W Local Area Connection Now go to Local Area Connection right mouse button Properties continue at item 4 DHCP Dynamic Host Configuration Protocol allows the automatic integration of a computer into an existing network optris PI NetBox E2013 01 A 14 3 Go to Local Area Connection the following status screen will be shown Then go to Properties 4 Mark Internet protocol Version 4 TCP IPv4 and go again to Properties 4 Local Area Connection Status 4 Local Area Connection Properties Networking General Alternate Configuration If this computer is used on more than one network enter the alternate IP EP Intel R
6. ally from your PC to the NetBox and stored there Now you should see the live picture from the imager on your PC optris Pl NetBox E2013 01 A 17
7. atic private IP address User configured IP address 192 168 0 1 Subnet mask 255 255 255 dl Default gateway Preferred DNS server Alternate DNS server Preferred WINS server Alternate WINS server V Validate settings if changed upon exit After you have made these settings and connected your PC with the NetBox using an Ethernet cable your PC will establish a point to point connection This procedure can take several minutes In the Network and Sharing Center your network will now be shown up as a non identified network Please start now the PlConnect on your PC and open the menu item Tools Extended Remote devices In the window which is appearing you should set a hook on Enable and enter the IP address of the NetBox 192 168 0 100 Press OK The software will establish a connection to the remote device imager automatically optris PI NetBox E2013 01 A 16 V Enable current 192 168 0 100 from 192 168 1 0 192 168 1 255 192 168 0 100 NetBox 12010001 One or more calibration files 212080008 were not found at the remote location Do you want to send them to the remote location 30 0 250 pm OK Kennlinie 12080008 62 0 250 pm OK Kennlinie 12080008 62 150 900 pm OK Kennlinie 12080008 62 M20 100 pm OK Restarting device E Overwrite existing files V Auto close when finished Please confirm with Yes The calibration files will be transferred automatic
8. ons 0 50 C 20 75 C 10 95 non condensing Anodized aluminum 113 mm x 57 mm x 39 mm Lx W x H 280 g IEC 68 2 6 3G 11 200 Hz any axis IEC 68 2 27 50G 11 ms any axis Windows XP Professional 8 48 VDC or Power over Ethernet PoE 1000BASE T 9 5 W additional 2 5 W for PI camera passive active via integrated fan for ambient temperatures gt 50 C COM Express mini embedded board Intel Atom Z530 1 6 GHz 2 GB SSD 512 MB DDR2 533 MHz 3x USB 2 0 1x Mini USB 2 0 slave mode VGA TVout Ethernet Gigabit Ethernet microSDHC card up to 32 GB 6x Status LEDs L1 L6 optris Pl NetBox E2013 01 A Installation The PI NetBox can be mounted easily on a DIN rail TS35 according EN50022 using the supplied rail mount adapter For this purpose please screw the 4 screws M4 into the designated holes on the upper side of the NetBox housing Now you can place the rail mount adapter on the housing and fix it with the 4 nuts On the bottom side of the NetBox housing you will find 4 holes M2 5 which also can be used for mounting Dimensions PI NetBox optris Pl NetBox E2013 01 A Controls and Connections Mounting holes for rail mount adapter 9 Cooling fan USB 2 0 connection 10 2x USB 2 0 connections Ethernet connection 11 VGA TVourconnection Power supply connection 12 Switch VGA TV out Mode switch S1 S2 Mini USB connection slave mode Status LEDs L1 L6 microSDHC card
9. optris PI NetBox Mini PC for optris PI series Operators manual PL JUI JS Ferdinand Buisson Str 14 CE Conformity C Optris GmbH D 13127 Berlin The product complies with the following standards EMC EN 61 326 1 2006 GERMANY Basic requirements EN 61326 2 3 2006 4n Safety Regulations EN 61010 1 2001 Te a n Fax 49 30 500 197 10 The product accomplishes the requirements of the EMC Directive 2004 108 EG and of the Low Voltage Directive 2006 95 EG E mail info optris de Internet www optris com Read the manual carefully before the initial start up The producer reserves the right to change the herein described specifications in case of technical advance of the product References to other chapters are marked as gt Warranty Each single product passes through a quality process Nevertheless if failures occur please contact the customer service at once The warranty period covers 24 months starting on the delivery date After the warranty is expired the manufacturer guarantees additional 6 months warranty for all repaired or substituted product components Warranty does not apply to damages which result from misuse or neglect The warranty also expires if you open the product The manufacturer is not liable for consequential damage or in case of a non intended use of the product If a failure occurs during the warranty period the product will be replaced calibrated or repaired withou
10. slot 1 2 3 4 5 6 7 8 optris PI NetBox E2013 01 A Protective Housing M25x1 5 SW 27 IP65 Protective housing Alu die cast optris Pl NetBox E2013 01 A Operation The PI NetBox can be used in three different operation modes 1 Converter USB Ethernet with direct connection to a PC point to point connection 2 Converter USB Ethernet with connection of a PC via a network or via the internet 3 Stand alone operation with a PI camera For powering the NetBox you either can use the supplied power adapter or a suitable industrial power supply with a voltage output between 8 VDC and 48 VDC gt Technical Data Alternatively the PI NetBox can also be powered via the Ethernet cable PoE Power over Ethernet For this purpose a PoE injector is needed part ACPIPOE Status LEDs The PI NetBox is equipped with 6 status LEDs L1 L6 LED Function LED lights up if NetBox is powered via PoE or by power supply via power connector NetBox is powered via PoE and in this case supplies 12V at the power connector Net data video frames are continuously transmitted through the network connection flashing the imager is connected to an USB port calibration files are loaded and raw data frames USB data are continuously delivered by the imager flashing Application OK the main application PlConnect or Imager Net Server is running Mini USB port a PC is connected to the mini USB port
11. t further charges The freight costs will be paid by the sender The manufacturer reserves the right to exchange components of the product instead of repairing it If the failure results from misuse or neglect the user has to pay for the repair In that case you may ask for a cost estimate beforehand optris PI NetBox E2013 01 A Content Description Scope of Supply Scope of Supply Lightweight version Maintenance Cautions Technical Data General Specifications Electrical Specifications Installation Controls and Connections Protective Housing Operation Status LEDs Ethernet Direct Communication Ethernet Network Communication Stand alone Operation Connection to a Network Device Point to Point Connection coo 4 O C1 C1 CQ A ROQ optris PI NetBox E2013 01 A Description The optris PI NetBox is a miniaturized PC which expands the optris PI series to a stand alone solution or which works as a USB to Ethernet converter This mode generates larger possible distances between process PI camera and process control PC The PI NetBox includes a Windows XP Professional operating system that allows the user to install additional software The housing of the PI NetBox is made of anodized aluminum the optional NetBox protection housing supports the usage in industrial environments IP65 NEMA 4 rating Scope of Supply Standard version PI NetBox incl micro SDHC card 8 GB Power supply 100 240 VAC