1. Installation Mounting It is recommended that for safety purposes your lighting effect be properly mounted using suitable hanging clamps and safety cable PSL offers a e Power supply 220 240V 50 60 Hz range of items which are ideal for safe mounting e Consumption 110W Use in a well ventilated area without obstruction tOo lp20 the fan e Weight 5 5Kg Cleaning The most important part of your lighting effect to keep clean are the filters as they allow the light output to transmit These should be cleaned with a soft damp cloth The body of the unit may also be cleaned in the same way We recommend internal cleaning be carried out by a fully qualified technician LED provided with the fixture are considered as consumable items so are excluded from the guarantee Important user information This product conforms to European Directive 2002 96 EC This appliance bears the symbol of the barrel waste bin This indicates that at the end of its useful life it must not be disposed of as domestic waste but must be taken to a collection centre for waste electrical and electronic equipment or returned to a retailer on purchase of a replacement It is user s responsability to dispose of this appliance through the appropriate channels at the end of its useful life For further information on waste collection and disposal contact your local waste disposal service or the shop from which you purchased the appliance Maintenance amp
2. e The unit must be installed and connected by specialized personnel e Always connect a safety retaining chain e Do not use in damp surroundings e Do not use in places subject to excessive vibrations e Make certain that the surrounding temperature is never more than 40 C or less than 10 C e Avoid using the unit in dusty surroundings e For internal cleaning contact a qualified technician e To ensure good light output clean lens frequently e The outside of the unit must only be cleaned with suitable products e Do not open the unit for any reason e f any repairs are necessary make certain that they are only carried out by qualified personnel Operation This lighting projector has been designed to function on a mains power supply of either www professionalsoundlight it Messain opera Questo apparecchio deve essere utilizzato con una tensione di 220 240Volts 50 Hz Controllare che la tensione di utilizzo sia quella indicata nell apposita etichetta posta sull apparecchio Pu funzionare in SOUND in modalit STAND ALONE oppure pu essere controllato via DMX Installazione Per fissare il proiettore utilizzare il foro posto al centro della staffa utilizzare appositi ganci e verificare la robustezza del sostegno ove si fissa l apparecchio collegare una catena o cavo d acciaio di sicurezza al corpo dello stesso Installare e utilizzare in un ambiente ventilato e posizionarlo in modo che non vengano ostr
3. Servicing Work on internal parts should be carried out by a qualified technician Removal of any covers other than the fuseholder is considered a breach of warranty and will not be covered under any such agreement unless authorized first by the company Troubleshooting If the unit lights but will not move adjust sensitivity control If after trying this solution you still have a problem contact your dealer or PSL Caution No user serviceable parts inside please refer to PSL for service Power Connections Should any other connections be required they must be carried out with the following configuration Earth Green Yellow cable Neutral Blue cable Phase Brown cable AS DISCONNECT POWER BEFORE OPENING THE UNIT QUALIFIED PERSONNEL ONLY IP 65 CONNECT A SAFETY RETAINING CHAIN MINIMUM DISTANCE
4. I PERLA SICUREZZA e Non apportare modifiche all apparecchio e Evitare che nell apparecchio penetrino liquidi infiammabili acqua oggetti metallici e comunque qualsiasi oggetto e Installare l apparecchio fuori dalla portata delle persone e Il montaggio ed il collegamento dell apparecchio deve essere fatto solo da personale specializzato e Fissare sempre il cavo di sicurezza al apparecchio e Non utilizzare in luoghi con eccessive vibrazioni e Evitare l uso con temperatura ambiente superiore ai 40 C o inferiori a 0 C e Evitare l applicazione in luoghi polverosi e Per la pulizia interna rivolgersi ad un tecnico qualificato e Per una buona resa pulire frequentemente il vetro di protezione e Pulire esternamente l apparecchio con prodotti appropriati e Non aprire l apparecchio pernessun motivo Per eventuali interventi necessari alle riparazioni sar tassativo ricorrere a personale autorizzato Before operating read and understand the user s manual Congratulations on the purchase of your new lighting effect We are confident you will enjoy many trouble free hours with this unit To assist with the care and use of the product we have prepared this short guide SAFETY PRECAUTIONS e Do not modify any parts of the unit e Make certain that no inflammable liquids water metallic objects or any other foreign bodies enter the unit e Install the unit in such a position that it is out of people s reach
5. Pannello di controllo display MENU NAVIGATION Address ADD li gt MENU DMX address set address UP LENPes g000 TEMP CHECK TEMPERATURE uP Y S HE yg 5 0 FOO00 DIMMER VALUE dimmer strobe speed __ gt MENU SE AE U25 0 MENU DIMMER VALUE dimmer u Addr DMX address DMX CHART 3 CHANNELS Ch1 0 255 MAIN DIMMER Ch2 0 255 SECOND DIMMER Ch3 0 255 Strobe from slow to fast Per utilizzare pi spot con il collegamento MASTER SLAVE 1 definire il proiettore Master e slezionare DIMMER 2 salezionare i proiettori Slave su Adde 3 collegare con il cavo di segnale DMX dallo spot Master Dmx out agli spot Slave DMX in Alette Paraluce cod V0007 35cm 35cm 5 5 Valori di luminosit misurati con il modello E0014 DL 10 5M 1400 Lux dist M 45 5M 320 Lux dist M 16cm Stage Spot LED 100W CE CODE WL0014 DL0015 SL Professional Sound Light Prima di utilizzare l apparecchio leggere le seguenti istruzioni Grazie per avere scelto un articolo nostra della linea diluci Confidiamo che la scelta soddisfi le vostre esigenze e faremo il possibile per aiutarvi affinch questo si realizzi Prima di utilizzare l apparecchio leggete attentamente il manuale di servizio e d uso dello stesso PRECAUZION
6. e Grado di Protezione IP 20 Alimentazione 220 240V Consumo 110W Peso 5 5Kg II LED installato nell apparecchio e da considerarsi materiale di consumo pertanto esclusi dalla garanzia Informazione agli utenti Questo prodotto conforme alla Direttiva 2002 96 EC Il imbolo del cestino barrato riportato sull apparecchio indica che il prodotto alla fine della propria vita utile dovendo essere trattato separatamente dai rifiuti domestici deve essere conferito in un centro di raccolta differenziata per apparecchiature elettriche ed elettroniche oppure riconsegnato al rivenditore al momento dell acquisto di una nuova apparecchiatura equivalente L utente responsabile del conferimento dell apparecchio a fine vita alle appropriate strutture di raccolta Per informazioni pi dettagliate inerenti i sistemi di raccolta disponibili rivolgersi al servizio locale di smaltimento rifiuti o al negozio in cui stato effettuato l acquisto 230V 50Hz and has been fitted with a suitable Technical Specifications power plug for use with your local voltage Check the label on the unit and the power plug for the correct voltage Can be SOUND activated STAND ALONE or it can be controlled via DMX 512 e Aluminium body e LEDs 100W White e DMX 512 protocol 3 dmx channels e Main dimmer Temperature Color white 4200 K mod DL E0014 Temperature Color white 3000 K mod WL E0015 e Strobe effect e Stand alone mode
7. uite le prese d aria dello stesso Pulizia periodica E molto importante per il proiettore la pulizia generale e in particolare del vetro di protezione per una buona trasmissione della luce Raccomandiamo di fare eseguire una pulizia periodica all interno dell apparecchio da un tecnico specializzato o in un centro PSL Manutenzione e servizio Ogni intervento sulle parti interne all apparecchio deve essere fatto da personale specializzato La rimozione non autorizzata espressamente dalla PSL di qualsiasi parte esterna per accedere all interno dell apparecchio eccetto il coperchio del porta fusibile sar considerata come causa dell interruzione della garanzia Anomalie Per ogni intervento contattare il servizio della PSL Precauzioni Non intervenire all interno dell apparecchio ma contattare il servizio PSL Connessione alla rete elettrica L apparecchio munito di un cavo per la connessione alla rete elettrica Se si utilizza una diversa connessione attenersi alla configurazione indicata Neutro cavo blue Fase cavo marrone Terra cavo giallo verde Specifiche Tecniche Telaio realizzato in alluminio pressofuso e acciaio 1LEDs 100W Bianco Temperatura colore del bianco 4200 K modello DL E0014 Temperatura colore del bianco 3000 K modello WL E0015 Protocollo DMX 512 3 canali Dimmer generale 0 100 Effetto strobo 0 15Hz Funzione Master Slave Settaggio funzioni tramite display digital
Download Pdf Manuals
Related Search
Related Contents
Manual - Automatismos Pujol HGMD_global_document - BIOBASE Biological Databases T-REX 150 DFC COMBO BTF König INK3-351XLCO ink cartridge Rainhandler RHP-5W Instructions / Assembly AS-CK Manual V09202013.cdr Mapa del sistema: Vista inferior Mode d`emploi Barre profilée Vario-Soft VSP Barre en titane Copyright © All rights reserved.