User and Installation Manual

image

Contents

1. cleaning to remove dust directly behind it e Clean the reflector and other parts excluding the burner tube and venturi gauze with water and mild detergent and a cloth or soft brush e Carefully inspect the burner tube and venturi gauze on damage cracks and holes Replace when needed e Check the injector for obstructions Remove obstructions by brushing them away and by using a pin or drill to clean the injector hole Make sure that the injector hole does not become wider by using a pin or drill that is larger than the size stamped on the side of the injector e Clean the inside of the gas safety device and injector with compressed air Make sure that the pressure of the compressed air is not larger than the 1 5x the pressure stamped on the safety device 65 or 1400 mbar Otherwise the rubber seals inside the safety device will become damaged e Check the condition of the thermocouple sensor Replace in case the tip is burnt in already to avoid unnecessary shut down later on e Check all gas carrying parts and connections for gas tightness with leak detection liquid or soapy water according the procedure in the standards applicable in the local installation situation Never use a flame for soundness checks e In case a gas hose is used check this carefully for cracks wear and other signs of damage or alteration Replace it also when the maximum lifetime printed on the hose or the maximum allowed by local requirements has passed e Commi
2. is used a solution can be to put the sensor for 15 minutes in a bucket with cold water during daily inspection of the barn Version okt 2012 9 manual number 0009 0420EN Fault finding table Trouble Action e Check if gas valve of the gas cylinder or gas line is open Check if gas cylinder is empty First ignition will take up to 60 or more seconds before gas is available Check if the injector is blocked Check if the gas pressure gas quality is identical to the pressure indicated on the data plate Keep button safety device pressed for a longer period up till 25 seconds Check if the thermocouple is connected properly to the gas safety Burner extinguishes device after lighting Check if the thermocouple tip touches the flame Thermocouple or magnetic coil of the safety device is broken Gas pressure lower than minimum requested Heater not suspended at 15 deg Gas pressure is too high Check the gas pressure with the data plate Check if the gas pressure regulator is broken Wrong gas is used Check data plate for the correct gas supply Venturi air inlet is blocked dirty Check the size of the venture and injector with the table Not enough fresh air available due to mounting situation Air filter is dirty Heater not suspended at 15 deg Wrong gas or pressure is used Check data plate with the gas supply Check if the injector or venturi are blocked or dirty Check the injector and venture size with the table Check if pipe sizes or gas hoses have suffic
3. 7073000 _ Blind rivet nut M4 2 01327000 Hose nipple 8mm 9 0245600 _ Venturi gauze flat 2 _ 01328000 _ Hose nipple 8mm smooth 20 03880000 _ Clamping ring venturi 3 00101000 _ Gas safety device 1 8 21 00200000 __ Thermocouple M8x320 3 00106000 Gas safety device whose nipple 22 02505000 _ Burner AP 1 36x85mm 4 01429000 _ Reducing nipple 1 8 3 8 Rivets 4 8x8 5 5 0092xxxx__ Thermostat consult factory eflector 24 6 01405000 _ Reducing ring 3 8 1 8 25 02510000 Burner AP 3 50x80 mm Distancering j g uspension frame 155mm 8 01301000 Injector holder j 27 013070xx_ Venturi 25x62 consult facto 9 01161oo _ Injector M8x0 75 consult factory 28 02459000 Venturi gauze ball 10 02530000 Dust filter small 29 00202000 _ Thermocouple M8x450 11 08893130 Venturi tube complete x 30 02516000 Burner AP 2 61x210mm 12 07130000 Screw SS M4x10 j3 0235100 Reflector Oval 13 03855000 _ Suspension frame 120mm 32 02352000 Reflector Square not shown 14 00158000 Safety device nut M8x1 33 08893100 Venturi tube complete 15 07135000 Screw SS M5x10 34 07059000 Rivets 4 8x8 8 SS Avinox 16 01799000 Connection piece 25mm _ 03903000 Suspension hook AP1 AP2 AP3 17 013060xx_ Venturi 25x40 consultfactoy lt Version okt 2012 11 manual number 0009 0420EN N30ZF0 6000 Jequunu jenuew a
4. L ZL0Z PO uolsISA eueyjow 00L seb jeunjeu 97H uedoud O jejd eyep au uo uoljguuojui nss id y osje s luo eunssaud Ajddns wnwixew uo payesedo aq jjeys 194294 ay UOISIOA IHL pue HL Joyful ssed q e yym p ddinb si Jeyeay y se2 U OL lt 4 6 98 vb 0 OI O oori 688 1VE900 u 6 O L LVO _ S9 L ezneB eq WB Gp 90d VE900 i u b Spl a UA 68EELVE900 ie ET 09L0dV 900 ojojo sm boss bz bz m m 7 fim co BBB c T T T T ojo LO 1D LO O LO u LO 909ENVE900 909EYNVE900 I w amd s s se pes es 68 LV 900 j aT E miss EE 09L0dV 900 o gt ww ew 10 4 6 sH MA SH MA J pjOH ENN x oINssaid sinssaid 1o o u Aojo uI Jojo lu uo mduinsuoo indu yeay Indul eH lddnSs ddnSs syew y fiM Bury unjue ssed Ag uie seg wnwuy wnwxen wnwuy uinuuixe nid std s LD LO LO NY st st ee N koaa aml mal pn pan bd J pm J qan pas S S o f o 10 N aqe IPS Iuu5S1
5. User and Installation Manual AP 1 AP 2 AP 3 Series Atmospheric stainless steel gas infra red heaters for use in well ventilated areas AP 1 AP 3 AP 2 AP 1 TE AP 2 TE AP 1 TETH AP 2 TETH AP 3 TE AP 3 TETH Alke BV Industrielaan 11a 3925 BD Scherpenzeel The Netherlands Tel 31 33 277 3824 Fax 31 33 277 3080 info alke nl www alke nl Version okt 2012 1 manual number 0009 0420EN Warnings Do e Read this manual carefully before installation and use and keep it for future reference Make sure that all daily users know the content of this manual e Install these heaters only in according with all applicable local and or national regulations for installation and ventilation of gas heaters e Use these heaters only in well ventilated environment e Before installation and use make sure that the required type of gas and gas pressure as mentioned on the data plate is in accordance with the local situation e Store gas cylinders always in accordance with national and local regulations e Use only gas cylinders with a gas isolation valve or gas lines with a main gas valve at the beginning In case more than one heater is connected to a gas system place also a gas tap directly before the heaters Close these taps when the heaters are not in use e Installation and maintenance shall only be done by competent and experienced installers e Make sure that during service maintenance cleaning and oth
6. amaged or worn If the last case is true do not use it and replace the seals first e After connecting the regulator firmly open the cylinder valve and check with soapy water if the connection is leak tight If bubbles appear the connection leaks Do not use the heater unless the system is sound Soundness check Before using a new built gas system first make sure that the installer made a careful and extensive check for gas leakage After executing a pressure drop test to determine that there are not large leaks check every connection with soapy water or gas detection liquid with all gas valves open and with maximum gas pressure Pay special attention to the hose connections Maintain maximum air ventilation during the test Repeat this check at least every year This soundness check shall be done by a competent installer only Gas leakage When a gas leak is detected immediately close the gas supply and disconnect electricity Keep flames away Do not use the heater anymore Contact an authorised gas technician gas installer or gas service agent to determine if the gas leakage can be repaired Never try to do gas repairs by yourself Do not use the heater anymore until the problem is solved Operation New heaters New heaters need a cleaning period before they are ready for operation Turn the ventilation to maximum position or place the heaters outside in the open air Fire the heaters for at least two hours on full capacity to burn
7. cated on the data plate Adjust the heat input by setting the thermostat knob at the desired value Note that the temperature on the ground will be several degrees higher than at the sensor So use the setting on the thermostat knob as a rough guideline and always check the real temperature on the ground Approx Ground temp Temperature THi 15 C 20 C 22 C 28 C 33 C 36 C 38 C AUN p Extinguishing the heater TE TETH and TETHi versions Close the gas tap or the central gas supply The burner will extinguish now The thermocouple safety valve will close after 60 seconds Visual examination of the flame Check after every ignition and also during regular barn inspection if a heater still burns correctly The flame shall remain always inside the burner tube The burner tube shall be equal red orange in high firing position and having a blue flame A burner does not operate well in case there is a green blue cloud inside the reflector and or a green blue flame tongue is coming out the exhaust hole in the reflector Soot deposit on the reflector and yellow flames are also a sign of bad functioning and are not allowed Cleaning will solve these problems in most cases Note that yellow tipping in low fire is allowed In high fire position the flame makes a soft roaring noise In case the burner makes a loud roaring noise and the burner tube does not become equal red orange the venturi gauze is damaged and the flame is b
8. directly after receiving them Note that the heaters will be a bit discoloured by temperature due to a 5 minutes quality check after manufacturing The heaters are pre assembled In some cases if there is a risk for damaging during transport the thermocouple sensor is separated from the gas safety device Re assembly can be simply done by screwing the M8 nut 29 of the sensor back on the safety device 14 Do not tighten too strong The thermostat knob is always delivered separated from the thermostat valve 1 Remove the protection cover from the thermostat valve 2 Turn the knob on maximum temperature and push the knob on the valve 3 Fix the knob by turning the large metal screw ring till it stops at least 2 turns hand tight For thermostats with a remote sensor only bend the sensor line carefully no sharp bends to the thermostat valve and secure the sensor line with a ty rap around the red protection lining and the thermocouple safety device see picture Note that the tubing is hollow a sharp bend will close the tubing and makes the sensor worthless The chance of breaking the line at the entrance of the thermostat knob is largely limited now Installation Place of installation The heaters are intended for use in well ventilated areas only Do not install the heaters in situations that are not well ventilated See also below for more ventilation information Check also your local regulations for the ventilation and room si
9. e hanging free and have a distance of minimal 1 meter from the ground This to make sure animals will not damage the hose Connect the hose via an individual gas tap to the central gas supply A guideline for placement of the sensor of the temperature regulation is 60 cm above the ground and minimal 40 cm away from a heater Use sensors with a black surface in case the regulation is based on measuring the infra red temperature Version okt 2012 4 manual number 0009 0420EN Gas line supply In case a main gas line supplies the gas to the heaters make sure that an authorised company in your country in accordance with the local rules and requirements install the system To avoid problems use galvanised or copper tubing for the gas line First make a calculation to determine the capacity of the whole system and the diameters of the piping in each section Use the common available calculation methods as written in most gas installation standards Contact an installer or the distributor in case this calculation method is not available in your area For data needed to calculate the dimensions of the gas line see the technical table on the last page The most common way to install a gas line is in the centre of the barn at least 2 meter high with every 3 to 5 meter a T or cross connection for gas supply to the heaters Always mount a easy reachable gas tap at the beginning of the gas hose to the heaters This gas tap is needed to clo
10. er work on the heaters gas lines and electricity are closed and the heaters are cooled down e These heaters are intended for heating of animals poultry barns workshops local outside heating projects and other similar heating purposes in agro or industrial environment e When gas is smelled or a leak is detected directly close the gas supply and immediately take care for good ventilation Do not touch any electrical switch or do not create sparks in another way Do not use the system before the leaks are solved and the system is safe again Consult an installer Ifa heater is not safe to use anymore remove it so that nobody accidentally operates the heater Store the heater in a safe place mark that it cannot be used and contact a service agent or gas installer to solve the problem Do not e These heaters are not intended for domestic use or for use in habitable parts of buildings and houses e Never use LPG heaters below ground level or in cellars or basements e Never use these heaters in small rooms or insufficient ventilated areas This can be dangerous and is forbidden e Do not use these heaters for other purposes than room heating Other use is not foreseen or evaluated and maybe will be dangerous e Do not use another gas or gas pressure than what is written on the data plate e Never use these heaters in rooms or areas where combustible liquids or vapours are used or stored or where there is a danger for dust explosions The
11. ient capacity Check the setting of the termostat e Burner does not light 4 Flames leave the confines of the burner or are sooting ora blue cloud is under the reflector The burner is only partly glowing The burner makes a lot of noise after ignition or after several minutes Gas pressure is not correct Check the gas pressure with the data plate Wrong gas is used Check data plate for the correct gas supply Check the size of the venture and injector with the table Sensor or wire thermostat is broken Thermostat valve adjusting mechanism is blocked There is insufficient heat in the building for heat loss i e not enough Heater will not attain the brooders desired temperature The thermostat sensing bulb is incorrectly placed The thermostat is out of calibration or broken The burner do not work at minimum position Declaration of conformity We Alke B V located in Scherpenzeel The Netherlands hereby declare that the AP series marked on their dataplates with CE and with CE approval production supervision by Kiwa Gastec number 0063 are in compliance with the following EU directive Directive on appliances burning gaseous fuels 2009 142 EC ex 90 396 EEC Scherpenzeel 01 01 2011 Adri van Alphen Derk Jan Keurhorst Managing Director Managing Director Version okt 2012 10 manual number 0009 0420EN Parts list No Part Description No Part Description 1 07000000 _ End cap black PVC 18 0
12. internally Advice Lots of farmers use a second set of dust filters They replace the dusty ones directly with the clean ones and clean the filters outside the barn to avoid unneeded disturbance of the animals Internal cleaning The internal part of a heater can be cleaned with compressed air or with a tube brush If needed do this every day First clean the outside of the burner tube Then the inside of the venturi and burner tube via the dust filter connection Repeat this 3 times to be sure the dust is removed Do not hit the venturi gauze while it becomes a bit brittle due to the temperature Water Never clean the heater with water steam or chemicals Also do not use high pressure jets to clean the heater The lifetime of the burner tube and venturi gauze will go down when it becomes wet and again hot afterwards In case an heater becomes wet unintentionally first make sure that they are dry completely before using them again High fire The lifetime of infrared heaters in a dusty environment will be extended in case these heaters are operated on high fire every 12 to 24 hours for minimal 15 minutes This burns off dust in the burner that accumulates during low fire operation This is only needed in case heaters operate on lower setting for a longer period When a barn computer is used for heating and ventilation it will be easy to modify the program to add a 15 minutes high fire operation every day In case a mechanical thermostat
13. ls depends on the specific local situation Keep in mind that there must be sufficient free space left to vent the combustion gases away Otherwise they will influence the combustion and proper function of the heater On locations where the combustion gases can vent away easily a minimum of 25 cm to the ceiling is advisable Note Be aware that some non combustible materials can be subject to discolouring when they become too hot Warning be careful with the use of heaters in places with storage of manure Manure can contain large amounts of methane and other inflammable gases Ventilation A proper ventilation is extreme important for safe and convenient operation Lack of ventilation can cause production of carbon monoxide very poisonous Sufficient ventilation shall be guaranteed by a monitored fan or by permanent non adjustable ventilation openings Consult EN13410 for more details Beside other important requirements this standard states in short that a 1 5 times room air replacement per hour is sufficient in most situations Also a maximum of 5W heat input per m3 room content is considered to be safe If this is not the case make sure that a minimum of 10m3 h air replacement per 1 kW heat input is guaranteed by means of fans or ventilation openings In case local requirements ask for more stringent ventilation or when animals ask for more ventilation always follow the most stringent requirements In case there are no requirements or sta
14. nce from the heater so it will not be over heated Advisable is at least 2 meters Make sure that the gas cylinder valve can easily be reached to close the gas supply in an emergency situation Pay special attention how to change the gas cylinders in a safe way For the AP 1 and AP 3 it is sufficient to have one gas cylinder 11 kg or larger per heater For the AP 2 a minimum of 1 5 gas cylinders of 11 kg per heater is needed for a guaranteed gas supply For a 45 kg gas cylinder a maximum of two AP 2 heaters is recommended Having more heaters on the gas cylinders as recommended above will give gas capacity problems especially when it becomes colder Gas hose In most installations the heaters are not connected directly to the gas system but a gas hose is used Keep the hoses always as short as possible especially for natural gas and low pressure LPG For high pressure LPG the maximum length concerning capacity issues is 5 meter The gas hoses must be inspected frequently and must be changed within the prescribed intervals Check the hose at least every 6 weeks Avoid twisting or stress of the gas hose Twisting or stress will shorten the live time of the gas hose During inspection check the hose for damage splitting ageing and cracking Pay special attention to the connections If a defect is seen directly change the gas hose by a new one of the same type Keep the hoses clean from dirt moisture and dust Version okt 2012 5 manual numbe
15. ndards for ventilation in the country of installation we advice to keep a minimum ventilation of 20m3 h per kW heat input Check regularly if fans are working properly and ventilation openings are not closed Installation The heaters are intended for suspension only Mount a chain with a S hook to the suspension hook of the heater optional part or use the two holes in the suspension frame to mount two short chains for making a hanging triangle see picture below The chain and S hooks shall be galvanised or made of stainless steel Mount the chain to a rigid part of the construction of the building Do not use the gas line gas hose or electric lines for suspension purposes Never use rope or plastic mounting materials Place the S hooks at such a place that the heater reflector makes an angle of approximately 15 degrees to the horizontal and with the gas safety device at the lower end Never hang the heater horizontally while in that case the flue gases will influence a proper combustion The gas safety device can handle a maximum temperature of 60 degrees Celsius Be sure that the heater is not mounted in such away that this temperature will be reached e g by other heaters in close vicinity Take into account the safety distances mentioned on page 3 After installation always check if the gas type and gas pressure complies with the technical table and data plate information Remove the black end cap from the safety device The gas hose shall b
16. off oily and greasy remnants of the production Make sure that after two hours all smoke and smell is disappeared The smoke and smell can be unhealthy so keep animals and human beings away till the heaters and the environment air is clean Ignition of the heater Warning after an heater is extinguished intentionally or unintentionally wait always for 3 minutes before re ignition This is a worldwide safety rule and intended to ventilate unburned gases away and to leave enough time for the thermocouple device to close Version okt 2012 6 manual number 0009 0420EN TE TETH and TETHi versions 1 Open all gas taps and turn the thermostat or gas pressure regulator on maximum 2 Keep a flame of a BBQ lighter or long match in the ignition hole of the burner tube 3 Press the knob of the gas safety device and wait for 10 25 seconds after ignition before releasing the knob 4 The burner will stay on now 5 Repeat al steps again in case the burner directly extinguishes Heat regulation of the heater TE version The heat input of this heater can only be changed by adjusting the pressure of the gas supply Check the gas supply pressure information on the data plate of the heater for the minimum and maximum values If only one pressure is mentioned adjustment is not possible and only continuous operation or on off operation is allowed TETH TETHi versions Make sure that the gas supply pressure remains constant at the value indi
17. r 0009 0420EN Some countries have regulations that gas hoses must be replaced every 2 or 3 years Please check with your gas supplier Always use official approved gas hoses suitable for the pressure concerning Replace a gas hose always by a type of the same length interna diameter and equivalent quality For safety reasons never use air hoses or water hoses these are very dangerous for gas transportation and will leak soon The gas hose shall always be connected to the heater with the help of hose clips Not using hose clips at both ends of the gas hose is very dangerous Make sure that the gas hose never is heated above 40 degrees Celsius Changing gas cylinders In case gas cylinders are used changing or connecting gas cylinders must be done preferably outside or in a well ventilated area in a flame free environment and away from other people e Check if there are no other operating heaters other gas heaters burning candles or people smoking cigarettes in the area e Be sure that the valve on the gas cylinder is closed and the burner of the heater is extinguished e Unscrew the nut by which the gas regulator is connected to the gas cylinder valve Note that most connections are with left handed threads They open in clockwise direction e Before connecting the new gas cylinder first check if the rubber seals on the cylinder valve or on the regulator connecting nut are fitted properly and able to fulfil its function and are not d
18. se heaters are not ATEX approved e Never cover these heaters with cloths or other materials for drying purposes e Make sure that never gas lines gas hoses electric lines etc are mounted directly above the heaters or are heated by these e Take care that gas hoses are not heated above 40 degrees Celsius e Never modify heaters The manufacturer does not take any responsibility for modified heaters e Bad installation wrong adjustment or incorrect maintenance can cause damage accidents or even personal injury or death e Do not touch move handle or service the heater when it is burning or in operation General information Model identification The main identification of the different models is AP 1 AP 2 and AP 3 These are independent atmospheric stainless steel infra red heaters Suffixes are used behind these model names to add additional type information about the models e g AP 2 CESKTETHIi CE that particular type is CE approved SK equipped with a single dust filter connection DS equipped with a dual dust filter connection TE equipped with a thermocouple safety device TH equipped with an independent thermostat and remote sensor 1 25 or 8 meter long THi equipped with an independent thermostat and integrated sensor Version okt 2012 2 manual number 0009 0420EN Packaging Normally depending model and order quantity the heaters are packed per 1 2 4 of 6 in a box Always check the heaters for transport damage
19. se the gas supply to the burners to extinguish the flames In addition it makes it possible to remove the heaters after use or to service the heaters safely The gas inlet at the heater side is standard a 8 mm hose nipple optional a smooth hose nipple or a G1 8 right handed thread Other connections are possible after consultation Always use approved gas sealant to close the gas connections Gas cylinder supply The gas can also be supplied from LPG gas cylinders The minimum size is a 11 kg cylinder or larger Before buying a cylinder make sure that the connections of the gas regulator and the gas valve of the cylinder are of the same type Check with your gas supplier for the correct size of gas regulator Check the technical table for the maximum gas consumption and gas pressure Store the gas cylinders always on ground level in a well ventilated place preferably outside the room where the heater is In case the gas cylinder is placed in a cylinder housing or cover make sure that there is enough ventilation as requested by the applicable regulations or standards Never obstruct these ventilation holes Make sure that the gas cylinders are used in upright position only and are secured again tipping over during use Gas cylinders laying on their side will give liquid gas This is very dangerous and will give a fire ball when it reaches the heaters In case the gas cylinder is placed in the same room as the heater is keep it at a safe dista
20. ssion the heater after maintenance and check it carefully during first ignition firing and extinguishing In case the heaters need to be stored for a long time make sure that no dust spiders etc can enter the heater Use the carton packaging box to store the heater or a plastic bag if the box is not available anymore and close this carefully Version okt 2012 8 manual number 0009 0420EN Daily maintenance In dusty or dirty environments check and clean a heater every day In case a heater is not cleaned internally the heat efficiency will drop and the lifetime of the burner tube and venturi gauze will become shorter or they will be destroyed Also there is a possibility that carbon monoxide poisonous will be produced and soot deposit will occur To keep the heater free of dust is important Dust filter Dust filters must be check every day and cleaned in case needed Remove a filter before cleaning Dry dust can be removed by tapping the filter softly against a solid surface like the sole of a shoe The dust will fall off easy now In case the filter is still not clean brush the surface gently with a brush or clean it with compressed air from inside to the outside In case the dust is greasy clean the filter in warm water with a bit detergent Make sure that filters are dry before placing them back Even with the use of a filter still check the heater regularly inside while very fine dust still will pass the filter and pollute the heater
21. urning inside the venturi tube back firing The venturi tube becomes very hot now behind the venturi Directly extinguish the burner and replace the damaged venturi tube and gauze by a new one Version okt 2012 7 manual number 0009 0420EN Birds and temperature The following list gives a rough guideline about birds days and temperature Realize that this depends on the conditions in the barn country and location and the kind and the breed of the birds Age Broilers Turkeys Guinea fowl Ducks days TempA TempB TempA TempB TempA TempB TempA TempB 40 37 Temp A Required temperature under gas brooder in C Temp B Required ambient temperature in C Maintenance General The frequency of maintenance is strongly depending on the quality of the combustion air and the intensity of use When used in poultry houses maintenance is advised every 6 weeks or by changing the animals By use in clean environment conditions the maintenance period can be extended but not longer than 6 months In case heaters are not used for a long period always do maintenance first before using them again Wear safety goggles during cleaning with compressed air Parts that are broken or are not functioning well must be replaced directly by identical ones of same brand and type Consult the dealer or manufacturer in case of doubt Order of maintenance e First clean the heater and filter as described below by daily maintenance Take the venturi out during
22. ze requirements The amount of heaters per building is depending the type of building the animals the insulation the climate and local wind conditions Check with your installer or distributor for a heat transmission calculation to determine the amount of heaters needed Make sure that the place of installation is free of draft less than 1 m s Too much draft will make the flames unstable and will result in a lower infra red heat efficiency It is advisable to install an alarm system that reacts on temperature in case a temperature drop will cause damage Find in the table below a rough guideline for the installation height to start with Adjust later on to the height based on your personal preference and experience Operational Distances AP 1 AP 2 AP 3 To the ground 50 75 cm 110 150 cm 60 100 cm Safety distance to combustible materials The heaters produce heat by radiation and by combustion gases It is important to take the following distances in account from the heaters to combustible materials This is to avoid fire or overheating Do not use the heaters in situations were the distances to combustibles are smaller Never store gases or inflammable liquids or easy combustible materials in close vicinity of the heaters Safety Distances AP 1 AP 3 AP 2 to the ceiling in front of the heater to the back to side walls to the ground Version okt 2012 3 manual number 0009 0420EN The minimum distance to non combustible materia