Home

Operating Instructions

image

Contents

1. G Hold the bench pane in the middle of the front edge and lift it Lock it in place using the lateral support TILTING DOWN THE CANOPY PANE SIDE PANE fobs Attention Prevent the pane from falling down when opening itl e Open the middle pane lock at last _ en Side pane NL MTL Le ati uh it l Operating Instructions mon amie deluxe 41 42 MOV Anue deluxe Open the 3 locking spigots by using the 5 hexagon socket screwdriver 3410055263 Observe the order Tilt the pane down REMOVING THE CANOPY PANE It is not usually necessary to remove the canopy pane supplied for maintenance and cleaning operations Should you prefer to work with the canopy pane removed though please proceed as follows Figure 14 Tilt the canopy pane down 6 Remove the strain relief of the display cable Phillips screw M4 Detach the display cable Operating Instructions mon amie deluxe Figure 15 Call in a second person and hold the pane at the two ends Then slightly lift the pane and remove it from the rear holding section 6 Carefully pull the pane towards the front and out of the tanning area Deposit the pane in a safe place ASSEMBLY NOTE Proceed in reverse order in order to re install the canopy pane Make sure that the pane seal is correctly positioned Figure 16 When closing the canopy pane make sure that
2. EUENTLOG ALAL 75 L STORE Tp PE EXT LD DOWN _ Lists the latest 99 events error codes amp info messages Detailed information is available by pressing the Start button Example no time date code tanning time 001 16 44 05 01 09 0011 03 23 002 15 22 05 01 09 0002 07 22 003 10 07 22 12 08 004 17 16 005 099 Regular maintenance is required for the safe operation of the tanning unit and must be documented Cleaning must be performed when necessary Live parts Risk of fatal injury due to electric shock when touching live parts e Disconnect from mains and secure against reconnection USE ONLY ORIGINAL SPARE PARTS Replace illuminants and filters only with ones wich are characterized on the device Use only original KBL ballasts art no 3200271131 for intelliSun and CPl Energy units Instructions for cleaning and care GENERAL Before starting to clean the unit take off any rings bracelets watches etc that you might be wearing in order to avoid scratching the surfaces e Cleaning fluid must not run into the appliance TUBES e To preserve the tanning power we recommend cleaning the tubes and UV lamps with warm water and a chamois after approx 200 hours of operation MAOVU CANU E deluxe ACRYLIC PANES GRAB HANDLES AND DOOR HANDLES e f possible use the special cleaning and disinfectant agent megaClean supplied by KBL for cleaning the acrylic parts
3. Operating Instructions Copyright 2013 KBL AG This documentation only covers products manufactured by KBL AG It must not be duplicated photocopied translated or stored without prior specific permission by KBL AG Duplication on electronic media or in machine readable form either in whole or in part is also prohibited DISCLAIMER All information given in this document correspond to the status quo at the date of publication but may be subject to changes Therefore we do not accept any liability for nor do we guarantee the accuracy and or completeness of the information Technical equipment and versions of the devices are in accordance with the legal prescriptions of the respective country of destination Export to the USA and Canada of the KBL products listed in this guide or operation of the systems in these countries are not permitted KBL does not accept any manufacturers liability in case this direction is not adhered to It is expressiy pointed out that any violation of the export operation prohibition will involve substantial risks of liability for the exporter and or operator Version BA_monamie_6808_GB_A Date 12 2013 Control Software version KBL 7 mon amie 01 35 Item no 0100036536 For instruction updates please refer to http www kbl support de KBL AG Ringstrasse 24 26 56307 Dernbach Germany Telephone 49 0 2689 9426 0 Fax 49 0 2689 9426 66 eMail mon amie kbl de www mon ami de A General
4. Contact your customer service SD card check replace SD card check replace Check connector parameter storage If necessary replace parameter storage Contact your customer service Use CAN BUS operaters V2 Check connector parameter storage If necessary replace parameter storage Check connector parameter storage If necessary replace parameter storage Operating Instructions mon amie deluxe 51 52 nicht Chk deluxe ERROR MESSAGES After the error has been eliminated all error messages must be acknowledged by pressing START on the interior display No 25 26 28 No 203 204 208 206 207 208 209 210 Zn 212 213 214 215 216 217 219 Operating Instructions Status message Frequency detection detection failed Frequency detection power supply connection faulty con nector X6 E6 Overheat Status message Fill level aquaCool canister low Connection aquaCool unit faulty Connection audio module faulty Connection inside display faulty aquaCool canister empty Aroma supply low please renew aircon condensed water canister full please empty Low battery charge please renew Connection preselect display faulty Connection RGB module faulty SD card missing SD card unreadable Connection to easy Care terminal faulty Voltage varies blease check No voice files on the SD card pleas check Connection rubinColl unit faulty D
5. the pane seal is correctly positioned Tubes TUBE REPLACEMENT CANOPY SIDE PART Tilt the canopy and or side pane down 4 To Remove the tubes When installing the tubes make sure that the tube inscription is visible If it is installed in a different position there will be no tanning Collagen boosters effect In the case of a defect replacement can only be After new tubes have been installed the made by qualified technical personnel Contact your operating hours of the tubes must be reset in service partner in this case the service menu REMOVING TUBE Interior unit lighting Figure 17 A The lighting from inside the unit is effected by high performance LEDs There are LED modules located inside the unit in the canopy and in the side part The O O outer decorative lighting also consists of LEDs r it tit In the case of a defect replacement can only be made by qualified technical personnel Contact your service partner in this case TUBE REPLACEMENT IN THE BENCH PART Figure 18 Page 41 Open the bench pane If the device is equipped with an air conditioning unit remove the ducting pane Remove the tubes Operating Instructions mon amie deluxe 43 AA MOV Anue deluxe Filter cartridges The cooling air for canopy and bench is filtered Your unit is equipped with filter cartridges and continuous service filter inserts Therefore purch
6. Activates and deactivates the aroma function Factory setting off E o ee En ee EN im i AROMA We AF aqualc testeucle Aromastatus resek press for 2s Skart press for Zs EXIT EXIT DOWN 2 sec halten Reset Reset gt after having exchanged the Aroma tin I A EXT DOWN Starts the aquaCool test 1 cycle 32 Operating Instructions mon amie deluxe AROMA Cycle time gt 1 5 min I 1 EXT DOWN _ Defines the aroma cycle time spraying time spraying interval Only be active on systems without Aroma Factory setting 1 Ai AROMA Aroma cabin automatic gt Door contact gt Intervall gt off I ET DOWN The cabinet scent release can be set at intervals controlled by a door contact switch or completely deactivated Factory setting off AROMA Aroma cycles per hour a L 1 i E P EXT DOWN For interval operation of the cabinet scent released the number of scent releases per hour can be set here Factory setting 3 Operating Instructions mon amie deluxe 33 AGIT CALE deluxe The menu item TIMER AROMA offers you A a switching cycle for each day of the week i NOTE SWITCHING CYCLES Using the setting monday sunday the switching cycle will be the same for each day of the week VVeek Switching cycle Monday Sunday Switching cycle Monday Tuesday Wednesday A 4 Thursday Frida
7. Displays the total operating hours of the UV tubes and includes a reset function and set function to set the value in steps of five via the buttons e Save settings by pressing STORE HOUR METERS SHS Operating hours collagen cubes gt 0183h a EXIT 1 DOWN 2 sec reset Displays the total operating hours of the collagen tubes and includes a reset function and set function to set the value in steps of five via the buttons e Save settings by pressing STORE Operating Instructions mon amie deluxe 9 HOUR METERS HABE Operating hours facial banner URI EXT T DOWN 2 sec reset Not available in this system HOUR METERS Humber of sumbaths al EXT EL DOWN 2 sec reset Indicates the number of tanning sessions sunbaths and includes a reset function Under the menu item FRESELECTION you can make the initial settings for the device The functions must be available and activated in this service menu SID STORE L O3 UDO FRESELECTIOM BLA UW Typ I 1 EXT DOWN _ Not available in this system 12 I sone Up I PRESELECTIOH IZA Audio gt SEudio Line In gt MPS inkernal gt MPS exkernal PP Ext D DOWN _ Determines the start setting of the audio source Factory setting MP3 internal STORE L UP FRESELECTIOM ZET Joice megaloice gt onm P P EXT DOWN _ m Specifies the start setting of the voice guidance system Factory
8. OME deluxe Collagen booster Canopy Locking bar with the locks for the canopy pane Control panel Line connectors in out player headset Base side covering Opening mechanism of the bench part Base faceplate Bench pane Side pane Canopy pane Air nozzles gepr fte Sicherheit Operating Instructions mon amie deluxe 9 Connecting the mains voltage Live parts IN Risk of fatal injury due to electric shock when touching live parts e Disconnect from mains and secure against reconnection Both the power supply and the related connection work must comply with national standards e g those set up by VDE in Germany The connection work must only be performed by qualified expert staff The connection to the 400 V mains must be protected by fuses Their specifications are listed in the chapter Technical data A residual current operated circuit breaker RCD with short time delay is absolutely required KBL AG recommends the following type KBL 3200 0770 00 type Typ ABB F 204 A 40 0 03 AP R Should the operation of the unit cause any interference in the power supply network e g with ripple control systems TRA consult your power supply company to have corresponding blocking elements audio frequency suppressors installed Figure 2 mains connection 400V 3N 50Hz coupling box with fuses see technical data and residual current operated circuit breaker RCD wit
9. SD card RECORDING TO THE SD CARD Attention S Do not modify or delete the VOICE folder or the data it contains Insert the card into the computer and wait for it to be recognised gt Copy files to SD card or delete files from it mO OME deluxe Replacing Aroma and aguaCool media O T i Attention Do not use any agents other than aquaCool and Aroma gel supplied by KBL Risk of infections Function of nozzles impaired REPLACING THE AQUACOOL CANISTER Due to the system a residual amount remains in the canister If the aquaCool canister is empty corresponding messages are displayed and aquaCool switches off shortly afterwards Figure 34 Page 41 Unscrew the lid Open the bench part Keep the hose end including the lid in a clean plastic bag while replacing the canister Replace the tin Operating Instructions mon amie deluxe 49 50 pni cr CALE deluxe REPLACING THE AROMA TIN When the Aroma tin is empty a corresponding message is displayed Figure 35 wh Page a Open the bench part Unlock the retaining bracket Replace the tin Reset the Aroma counter in the service menu gt to 0 Reset Then the message on the display will disappear Operating Instructions mon amie deluxe Replacing the aquaCool nozzles After 1 000 hours of operation the aquaCool nozzles must be replaced in order to ensure that the aquaCool system functions prope
10. appeared for the first time the aquaCool supply will last for approximately another 2 5 hours of operation If the system has run out of aquaCool liquid the aquaCool function is deactivated automatically and the symbol shown below is displayed aquaCool is automatically re activated as soon as a full canister has been connected cae Ak off ge 20 Operating Instructions mon amie deluxe AUDIO FUNCTIONS There is a maximum of three audio sources available at the user s disposal If you change over to another source you must activate it first The activation is effected by pressing the or the button All inactive audio functions are marked with OFF on the display so that you can easily recognise the active audio source MOVU CAE deluxe MODEL ACTIVATING AUDIO FUNCTIONS MP3 IHT OFF E F a us ACTIVATE FL as hips OFF E Variable section of the control panel audio functions Studio This function is used to play the studio music If the Studio function has been activated you can press the plus and minus buttons to browse through the channels provided that more than one channel is available MP3 internal MP3 IHT This function is used to play the tracks of the internal MP3 player of the Collarium the respective first title being selected by a random generator If the MP3 internal function has been activated press the plus and minus
11. dose 300 J m for 20 min The time between two tanning sessions must be at least 48 hours A Maximum 50 tanning sessions per year 15 kJ m Excessive dose of UV radiation Excessively prolonged tanning sessions may Cause severe damage to skin and eyes Never operate the Collarium with a defective timer Observe the tanning times given in the tanning schedule Switching the display By pressing the stop button in standby mode you may switch between the tanning mode preselec tion and the standard menu display After 20 sec onds the display switches back to the tanning mode preselection authomatically Preselecting the type of tanning Your MOr AMLE deluxe makes it possi D ble for you to choose between pure colla Si gen operation or a collagen UV mix UV amp collagen pure collagen START RS CLEAN LU ai tn Start of the collagen UV tan ning session In order to obtain the optimum effect the Collar ium automatically adapts the UV portion of the tanning to your individual skin type if desired For this it is necessary to measure the melanin with the mOr Annie skin sensor MOV Gtk deluxe Attention Clean the melanin sensor before measurement in the presence of the cus tomer For this always follow the instructions in the maintenance portion THE mnor armie SKIN SENSOR START p as g mon amie skin sensor terminal 1 Start button 2
12. information ie 5 About these instructions ccccseceseeeeeeeeeeeeeeenes 5 Transport by forklift truck ccccecessecseeeeeeeeeeeenes 5 Other modes of transport 5 Old equipment disposal ccceeceeeeeeeeeeeseeeeeeeees 5 LS a E AAE EA A E 5 Safety notes ssssnsnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn nnna 6 Intended use 6 Duties of the operator 02240224002nne nenn nenn nennen 6 Timer operation ccsccccecceseeceeeeeeeeeseeeseesaeeeeenenes 6 General safety advice 7 Collagen tanning times cccsscecseeeeeeeeceeeeeeees 7 Updating the system software cccssecseeeeseeeees 7 Description of the unit 2 200200n00nn0nnnnnn 8 SILO zo lt A ensure een 9 COMPON TIES se assiste ie derriere 9 CONMC CH ONS a SERERE 10 Connecting the mains voltage 10 Connecting an external audio source 10 Operation using different audio sources n 11 Connecting the channel selection 12 Connecting the external timer 12 aquaCool and Aroma connections 12 SARU ee 14 Operating modes 14 Collagen Tanning instructions 15 Notes regarding UV tanning nennen 15 Collagen tanning times nennen nennen 16 Collagen Tanning mode 17 Switching the display ccccccccsseeeseeeeeseeeseeeeeaes 17 Preselecting the type of tanning 17 Start
13. setting on __ STORE I UP FRESELECTIONM ace Aircon Aircandikian gt on ne Cr D Ext 1 DOWN _ m Fixes the start setting of the air conditioning sys tem Factory setting on STORE I UP FRESELECTION BS a Aroma on en PT Ext D DOWN _ m Specifies the start setting of aroma Factory setting on STORE I UP FRESELECTION Hea Aqua faqualool gt on ee I 1 EXT DOWN mi Specifies the start setting of aquaCool Factory setting on STORE L O3 UDO FRESELECTION brea Sum Ext DOWN Not available in this system five AUDIO BL ZZ Mp3 inkernal P L Ext T DOWN Activates and deactivates the internal MP3 player Factory setting off AUDIO AZ megallo ce gt an O EXIT DOWN gt off Activates and deactivates the voice guidance system megaVoice Factory setting on 20 D STORE I UP AUDIO AS 22 megaloice language gt englich german y L A O EXITO DOWN Fixes the language setting of the megaVoice system The following languages are fully supported GB RU DE FR IT PL CZ NL HU BG HR RO RS SK The following languages are supported in part DK EE LT NO ES SE TR exclusive easyCare Factory setting Depending on the operator coun try AUTO Studia Line In gt an gt otf o D EXT DOWN Activates and deactivates the Studio line in audio signal Factory setting on Operating Ins
14. sufficient airing and ventilation e Maximum relative air humidity lt 70 e Maximum room temperature lt 30 C e Minimum height of the room 2400 mm 1534 x 2380 x 1430 when closed 1942 x 2380 x 1430 when open 130 kg approx 620 kg with air conditioning Electrical connection values Protective class Mains voltage Wire cross section IP20 400V 3N 50Hz 5 x 4 mm lflex Supports SD cards up to 1 2 GB SD 4 16 GB SDHC Supported file system SD card FAT 16 FAT32 RIES EN Supported MP3 files constant and variable bit rate 96 320 Kbit s e Supported MP3 files USB Port constant and variable bit rate 96 320 Kbit s Fuses See unit data Air discharge Exhaust air socket 300 2095 mm top Minimum exhaust air flow rate 2250m h Exhaust air hose 300 Views eg 2 330 mm A 1 430 mm e 1534 mm gt w 1 942 mm Operating Instructions mon amie deluxe Tubes Collagen booster Nominal power Fuses UNIT DATA KBL mon amie deluxe Super Item no Equivalency code range Canopy 11x megaLine 2104 R 180W 3230076121 160 R 32 42 3 1 4 3 6x Collagen plus 2 1 18 3230076120 3x Collagen plus 1 8 18 3230076122 Side 3x megaLine 2104 R 180W 3230076121 160 R 32 42 3 1 4 3 2x Collagen plus 2 1 18 3230076120 1x Collagen plus 1 8 18 3230076122 Bench 10x megaLine 1917 R 120W 3230076123 120 R 36 48 3 7 4 9 10x Collagen pl
15. this e UV radiation from the sun or from UV devices can cause irreversible skin or eye dama These biolog ical effects depend on the type and amount of ra diation as well as on the individual sensitivity of the skin In cases of pronounced individual sensitivity or allergic reactions to UV radiation a physician should be con sulted before beginning tanning e After excessive exposure to radiation the skin may exhibit sunburn Excessively repeated exposure to UV radiation of sunlight or UV appliances can result in premature ageing of the skin and in a higher risk of skin cancer e The unprotected eye can suffer from surface in flammation and in certain cases e g after a cat aract operation excessive radiation can damage the retina After many repeated sessions a cata ract may form e Seek medical advice if persistent swellings or sores develop on the skin or if pigmented moles change in appearance FOR EACH TANNING SESSION e Always wear the supplied protective goggles Contact lenses or sunglasses are no substitute for the protective goggles e Remove cosmetics before tanning and do not use any sunscreen or products that accelerate tan ning e Allow for at least 48 hours to pass between sessions e After a tanning session in a studio do not take another sunbath out of doors on the same day e Protect sensitive areas such as scars tattoos and genitalia from radiation Operating Instructions mon amie d
16. 6 Lk OR AUDIO gt 2 a a Default volume standb ne I 1 EXT DOWN _ Sets the volume for the standby mode Factory setting 3 STORE I UP AUDIO den Maximum adjustable volume E E 1 i Cr DL EXT 1 DOWN _ Presetting the maximum adjustable sound level limits the maximum adjustable sound level in the operating and standby mode Factory setting 9 AUDIO 14722 megallo ce volume adaption gt 8S 09 dE PT Ext D DOWN _ Here you can adapt the volume of megaVoice Factory setting 00 dB 32 STORE I UP AUDIO 12 gt Dynamic volume adapk or gt an we PT Ext D DOWN _ Im Dynamic volume adaption on off Factory setting on 33 1d 1d dE P L EXT DOWN Sets the treble for MP3 USB operation Factory setting 00 dB AUTO 17 22 High bass MFZ USE gt 14 14 dB Cr DL EXT D DOWN _ Sets the high bass for MP3 USB operation Factory setting 00 dB AUDIO oy Low bass MFS USE gt 14 1d dE P EXT L DOWN _ Sets the low bass for MP3 USB operation Factory setting 07 dB __ STORE LOUP SOLID Id 193227 Wolume adaption Studia Line In 29 29 dB Cr T Ext D DOWN Here you can adapt the volume of studio line in sig nal Factory setting 00 dB 37 T STORE UP AuUbTo Treble Studia Line in gt 14 1d dE P EXT DOWN _ Sets the treble for studio music operation Factory settin
17. Care mode only EConly man time config T Display easyCare tanning time Adjust Set value quicktest STORE I 3 UDO EASYCARE ALAS easyCare mode only leonlui gt an oe gee 000500000 EXU DOWN J If this function is active the tanning session is strictly carried out on the basis of the values determined by the mon amie terminal Factory setting off STORE L UP EHSTCHRE man kime config Tbispl gt an oe ee O D EXIT DOWN J If this function is active the tanning time can be entered at the mon amie terminal The tanning power will be adapted automatically Factory setting off Operating Instructions mon amie deluxe 35 STORE L UP EHSTCHRENSETTINGS Jg syCare kanning kime Erin 26min 000 EXT DOWN Allows for preselecting the tanning time The tanning power will be adapted automatically Factory setting 20 min Pt STORE 3 UP EHSTCHRENSETTINGS CRE Adjusk PT Ext LD DOWN _ These settings must only be made by trained service personnel The default setting 1 must not be changed STORE TOP EHSTCHRENSETTINGS JE value quickbest gt 156 388 I 1 EXT DOWN _ These settings must only be made by trained service personnel Factory setting 244 Pt ORE I O3 Up __ EHSTCHRE EE Sensor Check o EXT DOWN Displays the current values during a melanin measurement This function is intended for sensor dia
18. Melanin sensor 3 Measuring point display fields 4 Display of the tanning time MELANIN MEASUREMENT Press the start button and follow the instructions of the acoustic menu navigation The melanin sensor 2 must be placed vertically on the point shown on the smor Amie skin sensor The respective display field lights up Repeat this procedure for all measuring points A 8 D until the acoustic menu navigation informs you that the measurement process was successful Operating Instructions mon amie deluxe 17 18 mO CALE deluxe MEASURING POINTS The collagen tanning session will commence automatically after the warm up time controlled by the timer has elapsed During the warm up time the tanning session can be started manually at any time by pressing the START button Operation during the session You can control the functions of the Collarium via the interior display during the session It is particular ly easy for you to access the basic functions Buttons with recesses that can easily be sensed al low for easy operation of the system even with your eyes closed NOTES 20 seconds after your last input the display changes over to the indication of the session time An information line at the bottom edge of the display informs you about currently selected features BUTTONS Control the basic func ZIERT l an 4 i Position ARROW BUTTONS recessed button Selection of the second
19. Replacing the aquaCool nozzles 50 mon amie SKIN sensor cccceeeeeeeeeceeeseeeseeesaeees 50 System messages uunnanunanunnnunnunnnnnunnnunnnnnnnnnnnn 51 Technical data 54 VEN ee een ee 54 About these instructions This operating manual is intended for use by operating staff users service staff Any person dealing with this unit must have read and understood these instructions This manual describes units equipped with the maximum number of features Keep this manual ready to hand at all times Transport by forklift truck The device is mounted on a pallet Insert the forks carefully into the openings of the pallet e Lift the load by a few centimetres e Transport the load carefully to the place of installation Other modes of transport Overturning load Danger of being crushed by heavy parts of the equipment Wear safety shoes If a forklift truck cannot be used for transport the box must be unpacked and the parts inside must be transported individually to the place of installation e g using a dolly Depending on the weight of the components lifting them might require several people Old equipment disposal This device consists of components that cannot be thrown into the household garbage Dispose of your old equipment in an environmentally friendly manner after the end of its useful life Metals and plastics can be recycled Electrical a
20. an runs on for 3 minutes in order to cool down the device The fan power is automatically decreased as the tubes cool down Your MGO ANLE deluxe is primarily a skin care system for the targeted build up of collagen It is op tionally possible however to administer a UV dose In this case follow the instructions below Notes regarding UV tanning As a rule an averagely tanning skin has achieved a uniform tan after three to five tanning sessions These sessions should take place every second day To preserve the suntan achieved one or two tanning sessions per week are normally sufficient NO SUNSCREEN WITH PROTECTION FACTOR Sunscreens with sun protection factors are unsuitable for use in a tanning salon For tanning the skin should have been thoroughly cleaned and be dry For optimum skin care we recommend using our line of body care products after tanning GENERAL e Any person that complies with the requirements laid down in the chapter Intended use may use the device e Never exceed your personal minimum erythema dose MED f reddening of the skin erythema occurs hours af ter tanning temporarily stop tanning e f unexpected effects such as itching occur within 48 hours after the first tanning session you should consult a physician before tanning again Once final tanning has been achieved additional tanning is only possible by greatly exceeding the permissible tanning times It is essential to avoid
21. and handles and dilute it in water at a ratio of 1 13 VARNISHED AND PLASTIC PARTS e Use a damp soapy cloth to clean the varnished and plastic surfaces e Do not clean the large plastic parts with a dry cloth This might scratch the surfaces CHROMIUM PLATED PARTS MIRROR e Only clean with a damp chamois and a cleaning agent for acrylic plastic antistatic Apply the cleaning agent onto the chamois and not directly onto the mirror surface CLEANING AGENTS e The surfaces and the acrylic panes must not be cleaned with concentrated disinfectants or solvents or other liquids that contain alcohol Operating Instructions mon amie deluxe 39 40 MAOVU ONE deluxe Component wearing part Condensate tank Air filter Tubes CPI devices Collagen booster Acrylic pane bench Acrylic panes others aquaCool nozzles Ropes of the canopy drive Air hoses Air conditioning unit Operating Instructions Cleaning care If a corresponding message is displayed Depending on local conditions after approx 100 operating hours After approx 200 operating hours After approx 200 operating hours When necessary When necessary When necessary Check and grease after 500 600 hours Check after 500 600 hours Clean the heat exchangers after 500 600 hours and check the condensate pump Maintenance intervals Replacement When necessary Typical value af ter abo
22. ary a functions a STOP BUTTON DISPLAY START TASTE Stops the tanning session if pressed for at least two sec onds functions Information line Operating Instructions mon amie deluxe Shows the menu items and Indicates the session time Starts the tanning session during the warm up time as well as after an interruption caused by pressing the STOP button provided that the booked session time has not elapsed yet not OME deluxe During the session you need quick access to basic functions such as volume control body fan and SUN ON OFF function You should also be in a position to change the subordinate functions The control panel caters for both requirements You have direct access to frequently needed functions via the Basic functions section and access to the subordinate functions you made via the variable section of the control panel display according to the rotation principle Basic functions Variable section of the control panel During the session you continue to have access to the subordinate functions If you wish to make any changes you can do so in the variable section of the control panel By pressing one of the arrow buttons A LA above or below the changeover symbol all available functions will be displayed one after the other according to the rotation principle You can switch these individual functions on or off and if possible make changes
23. ase and replacement of conventional filter pads are not required Clean the filter inserts after approx 100 hours of operation depending on the local circumstances Vacuum the filter inserts or use a dishwasher Figure 29 There are four filter cartridges each in the canopy and in the bench part NOTE Take the opportunity and check and clean the heat exchangers of the air conditioning unit See also the chapter Maintenance Ventilation and air conditioning Soiled heat exchangers substantially reduce the performance of the air conditioner Operating Instructions mon amie deluxe FILTER CARTRIDGES IN THE BENCH PART Figure 20 is Open the bench part Open the lock of the filter insert Remove the filter insert FILTER CARTRIDGES IN THE CANOPY PART Figure 21 Page 11 Fold down the canopy pane 25 Open the retaining clamp of the cartridge Remove the filter insert When installing the insert make sure that the honeycomb grill is directed towards the inside Canopy drive Bp 10 13 4 Se o lt c Service the wire ropes after each tube replacement in order to guarantee a trouble free operation of the drive Test the canopy drive The canopy must lock gt in place in all posit
24. ble volume 81 megaVoice volume adaption 62 Dynamic volume adaption Treble MP3 USB High bass MP3 USB 65 Low bass MP3 USB Volume adaption studio Line In 7 Treble studio line In High bass studio line in Low bass studio line In Service menu Structure overview p ictr ONULE deluxe VERSION 01 35 AQUA aquaCool aquaCool spray time Cycle time aquaCool start test cycle aquaCool endurance test aquaCool start initialization AROMA Aroma Aroma status reset Cycle time Aroma cabin automatic Aroma cycles per hour 61 TIMER AROMA 62 Aroma start test cycle AIR CONDITIONING 63 Air condition Start level body fan RGB 65 RGB mode EASYCARE SETTINGS easyCare mode only EConly 67 man time config T Display easyCare tanning time Adjust Set value quicktest Sensor check Volume UV LEVEL SERVICE Load factory defaults Personal PIN FIRMWARE TYP FIRMWARE VERSIONS SOFTWARE UPLOAD RGB Setup SERVICE MODE Service modus without tanning 1 Service modus with tanning 2 SOLARIUM IDENTIFICATION 3 SOLARIUM X CODE Reboot 45 EVENT LOG Operating Instructions mon amie deluxe 25 AGIT CALE deluxe EMUTROMMEHT In delivery condition some menu items are protected Contrast Personal PIN 2 paper ome pr re eal by a factory PIN Optionally the factory PIN can be gt PEAGA AOZA replaced by a Personal PIN C EXT JL DOWN Sets the contrast of the display You will receive
25. button 3 STORE If you fail to do so the system will not take over the changes you made gt See also chapter Service Menu Timeout e By pressing the STORE button you save all changes you have made in all menu items o EXIT DOWN _ e By pressing 8 EXIT you go back to the previous menu level or you exit the service menu SERVICE MENU TIMEOUT After performing your last operating action you have 2 minutes left to save the changes you have made Then a prompt appears and all changes are auto matically discarded after an additional 20 seconds SERVICE MENU AUDIBLE SIGNALS For user convenience operation and storage processes are acoustically acknowledged in different ways Operation process gt short sound Storage process gt long sound KBL 7 MON AMIE ENVIRONMENT 1 Language 2 Contrast TIME AND DATE TIMER DEKOLIGHT 5 Maximum tanning time HOUR METERS 6 Operating hours overall 7 Operating hours UV tubes Operating hours collagen tubes 9 Operating hours facial tanner Number of sunbaths PRESELECT AD UV Typ 2 Audio 3 Voice megaVoice Aircon Aircondition 5 Aroma Aqua aquaCool a7 Sun AUDIO MP3 internal megaVoice megaVoice language 1 Studio Line in usb MP3 3 MP3 external Line in Studio channel selection 5 Number of studio channels Music nonstop 7 Nonstop music source Default volume tanning Default volume standby Maximum adjusta
26. buttons to browse through the individual tracks MP3 external AUX MFP 3 EXT The audio module of the sundbed is equipped with a cable with a 3 5 mm jack plug so that you can make use of external players such as MP3 players iPods etc In this way you can connect the headphone jack of your player to the Collarium system Use the corresponding operating elements of the external player in order to select the desired tracks Looe I gt LOS Collagen booster a 0 EX Operating Instructions mon amie deluxe 21 22 AGIT CALE deluxe While the unit is in standby mode you can switch the decorative lighting of the unit on and off and trigger an aquaCool spraying test 1 spraying cycle When the unit is in service mode you can make the presettings for operation in tanning mode and you can have values concerning the operation of the unit displayed Layout of the display numbers The buttons of the interior display are allocated double functions In addition to the standard operating elements they stand for numbers that in standby mode provide access to standby and service functions Simply enter the corresponding sequence of numbers on the display 6 7 8 9 0 Operating Instructions mon amie deluxe Switching the decorative lighting on and off 5 0 5 NOTE The connection times of the decorative lighting can be set in the service menu individually for eac
27. e menu ON STORE UP OFF EXIT DOWN SERVICE MENU BASIC OPERATION The service menu is divided into the main menu and subordinate groups of functions If you choose a menu item e g AUDIO you will get access to all functions related to this item 2 Ae Select the desired function group from the MAIN MEN 1 EHUIFROHMENHT 2 HOUR METERS 3 PRESELECT main menu by pressing AQUA the 4 UP or the 9 anes DOWN button The 18 UU LEUEL currently selected group 13 Ebene aaa adi IS highlighted Pe e Press the START ENTER button to access the desired group menu STORE I UP Ts EASYCARE EXT DOWN _ The currently active function circle is displayed in the centre line on the left hand side You can invoke further functions of this group by pressing 4 UP or 9 DOWN Function group Function Settings mon amie deluxe Operating Instructions 23 24 CHANGE SETTINGS Depending on the respective function you can change values select options and switch functions on or off To do so use the buttons 2 and 7 Q BA STORE I UP O EHUIRONMENT Example Changing a value Masz mum banning Eime Imin Example Selecting an option german gt english Example Switching a function on off mon amie deluxe Operating Instructions STORE amp EXIT e Save your settings by pressing the
28. eluxe 15 16 MAE OAV CONNUE deluxe Collagen tanning times Your tanning time with the mnor Armie deluxe should be as pleasant as possible For this reason the UV dose to be administered is controlled by time and also by intensity The collagen intensity is con stant over time UV DOSAGE The UV dose to be administered is determined in dividually depending upon skin type before each tanning session with the aid of a skin sensor melanin sensor Based on this measurement the UV dose to be ad ministered is automatically adjusted by means of the fixed tanning time The administered UV dose will never exceed the maximum value of 300 J m lf no skin measurement is performed the minimum dose of 100 J m2 is automatically administered The UV tubes switch off automatically after 10 minutes The first tanning session must always be performed in this manner If no tanning takes place for four weeks the person tanning must begin with the first tanning session again This information is only in effect for devices that are maintained according to the intervals listed in the maintenance chapter cleaning and replacing tubes Operating Instructions mon amie deluxe Performing the first tanning session In order to ensure that no more than 100 J m are administered during the first tanning session this must performed without prior skin measurement Dose of first tanning session 100 J m for 10 min Maximum
29. escription Frequency detection failed Frequency detection failed No mains vol tage Device temperature too high Remedy Restart the controller Contact your customer service after the third unsuccessful restart Check mainboard connector X6 E6 Check the air intake air discharge system Let the device cool down INFORMATION MESSAGES Description The content of the aquaCool canister is sufficient for another 2 5 hours of operation with a spraying time of 6 seconds each Communication between control and module display has been interrupted aquaCool canister empty System has run out of scent Condensate canister of air conditioning unit full Button cell CR 2032 of the control board discharged Communication between control and preSelection display has been interrupted No SD card in the audio module SD card defective incompatible content Communication between control and easy Care terminal has been interrupted Power supply to the mainboard varies No voice files on the SD card found Driver collagen booster CAN BUS connec tion lost mon amie deluxe Remedy Replace the empty aquaCool canister with a full one Do not replace aquaCool with any other liquid Check replace the patch cable Acknowledge the message by pressing START If the fault persists contact your Customer Service Replace the aquaCool canister with a full one See chapter Refilling Aroma and aquacoo
30. exposed to UV radiation Operating Instructions mon amie deluxe 11 AGIT CALE deluxe Connecting the channel selection aquaCool and Aroma connec The following diagrams show the wiring of the chan tions nel selection on the audio equipment s side for pulse AQUACOOL coding as well as for BCD coding Figure 6 The aquaCool box is equipped with a liquid Wiring on the audio system of the studio level sensor 1 as well as with a connection to the aquaCool canister 2 Furthermore the box 8 houses the compressor ensuring the compressed air supply G and the Aroma box 4 with its related connections puls coding rol voltage c Figure 9 Figure 7 Wiring on the audio system of the studio BCD coding o ZT CHANNAL BCD 0 BCD 1 1 O O R p aa 2 1 0 3 0 4 1 Connector liquid level monitoring 4 4 4 2 Connection to aquaCool canister Compressor with compressed air connection Connecting the external timer 1 Dem Connect the external timer coin box studio control according to the instructions supplied with the timer The following diagram shows the wiring requirements with regard to the timer The door contact is required if you have opted for the booth scenting feature Figure 8 Wiring on the coin box external timer Operating Instructions mon amie deluxe AROMA The Aroma box is attached within the aquaCool box and equipped with three hose connections one for the compres
31. g 00 dB I STORE UP AUDIO ayes High bass Studio Line in DT dE PP Ext D DOWN _ Sets the high bass for studio music operation Factory setting 00 dB AUDIO ee Low bass Skudio Line in gt 14 14 dB pr EXT LE DOWN _ Sets the low bass for studio music operation Factory setting 07 dB Operating Instructions mon amie deluxe 31 AGIT ANUME deluxe aquaCool endurance kest Fan gt off gt on LEXI Hp DOWN s aff L A EXT EL DOWN a Activates and deactivates the aquaCool function Starts the aquaCool endurance test After having selected and stored the on setting you must Factory setting off leave the service menu and start a collagen tanning session Attention aquaCool will continue to spray permanently during a whole tanning session TT STORE up ee AQUA Be t Factory setting off aquaCool spray kime eo ae Cr T Ext D DOWN _ Determines the duration of the aquaCool spraying gt AQUA Maui nen in time u Start press for 2s Factory setting 6 PP Ext D DOWN _ Starts the aquaCool initialization process Aspraying cycle of 90 seconds is started to bleed the system before commissioning or after a repair operation _ 7 STORE UP a AQUA 83 86 Cycle time on S anti I 1 EXIT OT DOWN Defines the aquaCool and aroma cycle time on spraying time spraying interval en gt A EXT L DOWN Factory setting 1
32. gnosis to be performed by qualified service staff Operating Instructions mon amie deluxe l OR EHSTCHRE Uolume 78 4 9 PT Ext D DOWN _ Sets the volume of the easyCare voice guidance system Factory setting 4 UU LEUEL SET UU LEUEL FIH PU EXT DOWN Not available in this system OR SERVICE o Loads the factory default settings PERSONAL Q ER UP PIN SERWICE A2 1E FERS HRL FIH press ENTER O o O T DOWN Submenu call with START ENTER SUBMENU SERUICESPERSOHWAL FIH HILEL PERSONAL Bo ENTER SOLARIUM FERS OHRL FIH N FIH Cr T Ext D DOWN _ PERSONAL PIN activate deactivate Enter your personal PIN SERVICE ZETE FIRHHARE TYF gt press enter EXT T DOWN Submenu call with START ENTER Displays the current firmware typ variant SERVICE aq 16 FIRMMIARE VERSIONS gt press enter P EXT d DOWN _ Submenu call with START ENTER Displays the cur rent firmware version of the system components Do not operate the system with different firmware versions All system components must be equipped with an identical firmware version Pt SERVICE AL 14 SOFTWARE UPLOAD press enter Ext EL DOWN Submenu call with START ENTER Displays the first and the last Software Upload SERVICE RRE zekup ze De I 1 EXT DOWN _ Not available in this system PERSONAL PIN SEP Mis SERUICE MODE
33. h short time delay Typ ABB F 204 A 40 0 03 AP R KBL 3200077000 PE L1 L2 L3 N green yellow black or 1 brown or 2 grey or 3 blue or 4 Operating Instructions mon amie deluxe Connecting an external audio source When connecting an external audio source studio music pay attention to the correct polarity Figure 3 Wiring on the audio equipment s side Level adjustment studio signal The voice audio system components are built in the middle of the bench part vacuum housing of the device The potentiometer which serves of the external audio signal is located on the left side of the housing To avoid overdrive select the level adjustment accordingly The level setting mainly depends on the strength of the external signal and should be carried out by a service engineer Adjustment of the sound level can only be conducted Figure 4 Operation using different audio sources The unit can be operated using the following audio sources e An internal audio source e Various external audio sources e All available audio sources The audio source can be changed at any time by using the control panel INTERNAL MP3 PLAYER When using the internal MP3 player you can either play the music tracks that are originally supplied on the SD card or you can record your own tracks to the SD card EXTERNAL AUDIO SOURCES LINE IN As an external audio source you can connect devices ranging from the standard line le
34. h day of the week There are two independent connection periods A and B available for each day of the week Collagen boosters in standby mode In standby mode the collagen boosters work as dec orative lighting with minimum power For testing and demonstration purposes the three operating modes can be activated via the control panel After 10 sec onds the boosters automatically switch back to the decorative mode aquaCool spraying test 4 9 4 Invoking the service menu 1X6X1XO0OX0X0X0O NOTE Do not let too much time pass between the individual keystrokes when entering a sequence of numbers Service menu Basics In standby mode the service level is accessed by entering 161 followed by PIN 0000 There is one additional condition that must be fulfilled e No incoming signal from the coin box system SERVICE MENU ELEMENTS After having entered the service PIN the service STANDARD OPERATING menu is at your disposal Navigation is made via the following buttons see also chapter Layout of the display numbers e Use buttons 4 UP and 9 DOWN to browse through the individual menu items and functions e Press the START ENTER button to go to the corresponding submenu e Button 2 and 7 are used to switch functions on and off and to modify values e Press 3 STORE to save all modifications made in all menu items e Press 8 EXIT to go back to the previous menu level or to exit the servic
35. ions If it does not the can opy springs must be tensioned Check the ropes of the canopy drive Should gt individual wires be frayed replace the rope immediately Grease the rope in the area of the return pulley gt with copper crease or adhesive lubricant HHS 2000 KBL 1200024000 REPLACING THE SPRING LOADED WIRE ROPES PREPARATION Figure 22 Page 1 Open the bench part Disconnect the cable connections of the audio system only on right hand side Pay attention to the correct connections according to the colours during the subsequent assembly gt Close the bench MO OME deluxe Figure 23 Remove the foot panel and undo the cable of the decorative lighting 3 Figure 24 Remove the side panel gt pull forward Figure 25 on k 4 fi A I _ a a AN Remove the screw M6x12 of the shoulder tanner or the shoulder part Operating Instructions mon amie deluxe 45 46 MOV QI deluxe Figure 26 Tilt down the side pane D Loosen the hexagon socket head screw SW10 by approx two turns Remove the hinge cap Operating Instructions mon amie deluxe F i Tilt the can
36. l Replace the Aroma tin See chapter Refilling Aroma and aquacool Empty the condensate canister of the air conditioning unit acknowledge the message by pressing START Replace the button cell CR 2032 Check replace the patch cable Acknowledge the message by pressing START Insert an original SD card See chapter Recording to an SD card Removing the SD card Insert a new original SD card Acknowledge the message by pressing START See chapter Recording to an SD card Removing the SD card Check cable connections and power supply Acknowledge the message by pressing START Check power supply to the mainboard Rebuild voice folder on the SD card If necessary replace original SD card Contact your customer service No 220 22 pep 223 226 227 Status message OW to many sensors OW sensor Typ B missing OW sensor Typ S missing OW sensor read error Quicktest Sensortoleranz OK Quicktest Sensortolerance error rr ri RAME deluxe INFORMATION MESSAGES Description Remedy General OneWire sensor error Contact your Customer Service Sensor Quicktest log entry No display appears Message will be stored directly in the event log service menu Operating Instructions mon amie deluxe 53 54 MOV AMULE deluxe Ambient conditions Installation site Weights and measures Dimensions in mm Height x width x depth Bench pane max load capacity Weight In dry rooms booths with
37. nd electron ic components must be disposed of as e waste Flu orescent lamps must be dropped off at authorized collection points for pollutants This helps to avoid damaging effects to the environment and human health caused by improper disposal This makes a valuable contribution to recycling and other forms of utilization of old electrical and electronic equipment You can obtain information about environmentally friendly disposal from your local government or the municipal administrations Service For all service related questions please contact your responsible specialist dealer Operating Instructions mon amie deluxe X 5 6 This chapter provides a summary of general infor mation on safety and proper handling of the device More specific safety advice is given in other chapters of the operating manual Intended use The unit is intended to be used for the tanning of one single person at atime This person must not fall in one of the categories mentioned below otherwise using the tanning equipment is prohibited for him or her The following individuals must not use the tanning system e Persons under 18 years of age e Persons with heart pacemakers e Persons who are suffering or have suffered from skin cancer or have a predisposition toward this or those whose first degree relatives are suffering or have suffered from malignant melanoma black skin cancer e Persons taking photosensitive medicatio
38. ns e Persons who are being treated by a physician for conditions associated with photosensitivity e Persons suffering from acute sunburn e Persons who are prone to freckles Persons with atypical discoloured skin areas or and with more than five atypical moles with a di ameter of 5 millimetres or more and persons with more than 16 moles with a diameter greater than or equal to 2 millimetres If in doubt consult a phy sician e Persons who had several severe sunburns as chil dren e Persons with naturally red skin colour Operating Instructions mon amie deluxe e Persons who do not tan at all or cannot tan with out getting sunburn e Persons who have a predisposition toward sun burn Furthermore this tanning unit has been designed for use by individuals who are in full command of their physical sensorial and mental faculties Moreover sufficient Knowledge and experience are required During the operation no other persons shell be in the radiation range of the device Children should be supervised to make sure that they do not use the unit as a toy Duties of the operator KBL AG cannot be held liable for any damage resulting from improper use of the equipment or non observance of these operating instructions Only use original replacement parts Only replace tubes and high pressure lamps with those listed on the device Otherwise this voids the operating authorization and warranty Timer operati
39. of the collagen UV tanning session 17 Operation during the session 18 Variable section of the control panel 19 Basic TUNG ONS nenne 19 Function overview cccceecceeeeeeeeceeeseeeseeeeseeesaees 20 Standby mode service mode manu 22 Layout of the display numbers 22 Switching the decorative lighting on and off 22 Collagen boosters in standby mode 22 aquaCool spraying test 22 Invoking the service menu 22 Service menu Basics n nnannnonnnenennnnoennnnnnnnennnnne 23 Service menu Structure overview nuneenneneneneenennenn 25 Operating Instructions mon amie deluxe Personal PIN sisarvevionrissavednawennatnsnusetndgntvunbueeneneeabovns 26 Service MENU OPTIONS ueaenennnenennnnennnnenennenennenn 26 Maintenance and cleaning ss ssssnnsnnnnnnnnnnnnnnnnnnn 39 Instructions for cleaning and care 39 Maintenance intervals esuuessnensnnennnenenennnnnnnennn 40 TOOS and AIS see nc nd 40 Unlocking the Dench cccceeceeeeeceeeceeeseeeseeees 41 Acrylic DAN CS aussen ernennen 41 WD SS a a ad ao 43 Collagen boosters nennen nennen nennen 43 Interior unit lighting Rn nn nenne nennen 43 Filter cartridges 222022200240020n0nnnn nenn nnnn anne nennen 44 Canopy CNV E ecen 45 Ventilation and air conditioning u 2200 47 Recording to an SD card 48 Replacing Aroma and aquaCool media 49
40. on The tanning unit must be controlled via an external timer Should the external timer fail an internal timer will switch off the system automatically after 44 minutes General safety advice e Follow all instructions given in this manual In addition observe all relevant statutory provisions and regulations also those applicable in the country of operation e The unit must only be installed and assembled by specifically trained staff e Arbitrary modifications or conversions of the equipment are not permissible Observe all danger signs and safety notices attached to the equipment Safety notices must not be removed and safety equipment must not be disabled or removed e The unit must only be operated when in perfect working condition e Never operate the unit with the outer covers or acrylic panes removed e The collagen tanning system must be controlled via a timer that complies with the generally applicable standards e Absolutely observe the maintenance frequencies indicated in the maintenance plan e Pay attention to the load limit of the bench pane tanning bed units only Collagen tanning times Adhering to collagen tanning times and schedules is essential Updating the system software A ATTENTION Risk of damage by switching off the power supply voltage Disconnecting power supply during the up date process will lead to damage of electronic components Make sure that the uni
41. onday sunday the switching cycle will be the same for each day of the week VVeek Switching cycles B Monday B ON Sunday B OFF Day Switching cycles B B ON B ON B OFF B ON B ON B ON B ON B ON Switching cycle B Tuesday 08 30 12 00 14 30 22 00 STORE I Up EHUIRONMENT TIMER DEROLIGHT press ENTER O o CO Ext D DOWN Entering switching times for the decorative lighting The submenu is invoked by pressing START ENTER SUBMENU TIMER DECO LIGTH SELECT DAY OF THE WEEK ENTER SWITCHING TIME EHUIRONMENTSTIMER B14 gt Day ADH gt Day AOFF PE EXT DON gt Day BOW gt Day BOFF er SET SWITCHING CYCLES SL STORE I UP EHI NT 1EHTTIMER lsd Monday Q H 8 08 23 59 ra EXT LE DOWN LY y Set the time Select input e Save settings by fields pressing STORE start set Operating Instructions mon amie deluxe 27 AGIT CALE deluxe STORE I Oo UP EHUIFOHMENT Oe gt Erin 44min Maximum kanning kime PE EXT DOWN Sets the maximum tanning time for all timers In the easyCare operating mode the setting has been fixed to 30 minutes Factory setting 44 minutes HOUR METERS Operating hours overall arash Pp D EXT DOWN Displays the total operating hours ORE UP HOUR METERS 12 05 Operating hours UW Eubes gt 0183h V V DOWN EXI X LY 2 sec reset
42. opy pane down Remove the front fastening of the end cap of the canopy Phillips screw Figure 29 Remove the end cap of the canopy and pay attention to the cable of the decora tive lighting 69 Disconnect the cable connection of the decorative lighting on the inside of the Canopy end cap REPLACING THE SPRING LOADED WIRE ROPES Figure 30 Involve asecond person to secure the canopy against falling down Greasetheropeinthe area ofthereturn pulley with copper crease or adhesive lubricant HHS 2000 MOV CANLE deluxe Ventilation and air conditioning In order to preserve the performance of the air con ditioning unit clean the heat exchangers after 500 600 hours of operation Figure 31 Heat exchanger Condensate pump Condensate tray Open the bench part Clean the heat exchanger Vacuum it carefully paying attention not to damage the fins Operating Instructions mon amie deluxe 47 48 SERVICING THE VENTILATION SYSTEM gt Check all hose connections Remove any kinks in the air hoses Replace defective hoses immediately The exhaust air hose must not exceed a maximum length of 6 m if there is no auxiliary fan installed CHECKING THE CONDENSATE PUMP The condensate pump pumps away the condensation water at timer controlled intervals Check the function of this pump with each tube replacement Fill some water into the condensate tray Use a hose and a funnel to do
43. press ENTER O o CO Ext D DOWN Submenu SERVICE MODE Invoked by pressing START ENTER SUBMENU SERVICE MODE Service mode without tanning Service mode with tanning SERWICE ALAZ Service mode wikhouk kanning gt Shark press ENTER for 2s PT Ext 1 DOWN _ Troubleshooting mode The service mode is switched on for 30 minutes The mains voltage is connected Error notifications are ignored but tanning cannot be started Operating Instructions mon amie deluxe 37 AGIT ANUME deluxe STORE L UP SERVICE be Az Service mode with kanning gt Skart press ENTER for 2s PP Ext EL DOWN Troubleshooting mode The service mode is switched on for 10 minutes The mains voltage is connected Error notifications are ignored tanning can be started After this peri od there is a 3 minute restart lockout SERUICE X SOLARIUM ICENTIFICATIOH press enter O EXT I DOWN Show the characteristics of the device Configuration code Variant code Serial number f a STORE I UP PIN SERUICE FEB SOLARIUM CObE FIH PE E JL DOWN _ Branches to further configuration options These settings must only be made by trained service personnel STORE TP SERVICE 18 16 Feboot gt Reboot press fo gt Q Performs a restart of the electronics Attention All unsaved changes will be discard ed Operating Instructions mon amie deluxe
44. rial number CAN BUS Interior display V1 is incompatible CAN BUS preSelection display V1 is incompatible CAN BUS audio module full V1 is incompatible CAN BUS RGB module V1_ ist incompatible Parameter storage write error Parameter storage read error Description Bimetal switch triggers Enabling signal from coin box system comes in longer than the time value approved under Maximum tanning time voltage remains connected Bimetal switch in the fan triggers Faulty communication between mainboard and fan speed control Contact of the canopy pane has triggered Contact of the side pane has triggered Contact of the bench pane has triggered Mainboard defective Maximum write cycle flash memory reached Update via SD card failed CRC fault Update via SD card failed access error Parameter storage not found please con nect and restart Parameter storage no valid serial number CAN BUS operators incompatible Parameter storage write error Parameter storage read error Remedy Check the air intake air discharge system Let the device cool down Disconnect from the coin box system Make sure the fan runs freely Check the air intake air discharge system Let the sunbed cool down Check replace the patch cable Close the canopy pane and check the contact Close the side pane and check the contact Close the bench bench pane and check the contact Contact your customer service
45. rly The assembly instructions are included with your spare parts delivery mon amie skin sensor Do not use any concentrated disinfect ants or solvents or other liquids that contain alcohol CLEANING THE HOUSING e The plastic housing should be cleaned as needed e Only use a cloth that has been dampened with a mild soap solution to clean the surfaces of the housing e The cleaning solution must never get into the housing CLEANING THE MELANIN SENSOR e Clean the melanin sensor before each use in the presence of the customer e Use only a common disinfecting cloth for cleaning e The cleaning solution must never get into the mel anin sensor ERROR MESSAGES After the error has been eliminated all error messages must be acknowledged by pressing START on the interior display No 01 02 03 04 08 09 10 12 13 14 15 17 18 ic 20 21 22 23 24 Status message Excess bimetal canopy temperature Maximum tanning time Excess temperature exhaust fan please check Connection fan speed control faulty Canopy pane open please close Side pane open please close Bench bench pane open please close KBL7 Hardware error Input Con troller Maximum write cycle flash me mory reached Error SD card read error CRC fault Error no access to the SD card Parameter storage not found please connect and restart Parameter storage no valid se
46. sed air supply 5 and two leading to the Aroma nozzles 6 Figure 10 5 Aroma box inlet 6 Aroma box outlets not OME deluxe Operating Instructions mon amie deluxe 13 14 Before switching on for the first time e Fix the supplied warning sign or one with the following wording permanently to the wall close to the unit e Determine the presettings for the device in the ser vice menu e Check correct installation of fluorescent tubes The tube labeling must be visible otherwise no ef fect may be obtained e Store these Operating Instructions in a place that allows for easy access at any time Operating modes The three different operating modes are explained below STANDBY MODE The unit is in an idle state i e it is connected to the mains but is currently not being used The tubes are switched off From the standby mode you can change over to the collagen tanning mode or to the service mode Operating Instructions mon amie deluxe COLLAGEN TANNING MODE The tubes are switched on and a collagen tanning session is in progress While the unit is in collagen tanning mode the settings for the ongoing collagen tanning session can be changed via the control panel SERVICE MODE In the service mode the device is configured for the collagen tanning mode Various values can be displayed and test functions can be carried out FAN RUN ON After the collagen tanning session the f
47. so D Make sure that the water does not spill over Start a tanning session and then wait for 20 minutes The filling level of the tray must then be below the pump level Operating Instructions mon amie deluxe EMPTYING THE CONDENSATE TANK The condensate pump transports the condensation water into a canister via a hose Once this condensate canister is full a corresponding message is displayed The air conditioning symbol flashes check and the air conditioning unit switches off shortly afterwards Figure 32 Unscrew the closing lid of the condensate canister Empty the condensate canister When closing make sure that the condensate hose is inserted a max of 50 mm into the canister Finally acknowledge the aircon message on the display START Recording to an SD card O REMOVING THE SD CARD The SD card slot which contains the storage medium with the MP3 data from the internal MP3 player is located at the control box in the bench part of the device Figure 33 Please refer to the chapter Technical data for information regarding supported card sizes as well as file system and MP3 formats The SD card must not be formatted the Voice folder and its contents must not be changed or deleted Outside of this folder you can add or delete audio files as you desire These audio tracks are played if the corresponding source has been selected The number of files is limited by the storage capacity of the
48. t is not disconnected from the power supply voltage during the update To accomplish the update download the USB Con nect software offered by KBL For detailed informa tion press the help button in the main menu Operating Instructions mon amie deluxe 7 Molt CINE deluxe Description of the unit Congratulations With your 11671 CME deluxe YOU have purchased an original Collarium A combination of special collagen tubes to build up the collagen deposits in your skin in conjunction with optional UV tubes to create a subtle tan makes your MOr AMLE deluxe a one of a kind skin care system In addition your mOr AME deluxe has a medi cal skin sensor This measures the melanin content of the skin and thus ensures individual and safe tan ning 8 Operating Instructions mon amie deluxe Standards This Collarium complies with the following stand ards in their respectively applicable version e EN 60335 2 27 e EMC 2004 108 EC e Low Voltage Directive 2006 95 EC Components The Collarium basicallly consists of the following components e The canopy including 11 UV tubes 9 collagen tubes 80 collagen booster and control panel e The side part including 3 UV tubes 3 collagen tubes and 10 collagen booster e The base part including 10 UV tubes 10 collagen tubes the electronics unit and further optionally available components KBL NON Anue deluxe Figure 1 O ON oO 10 12 trot
49. the Personal PIN with the prod uct documentation Factory setting 00020 The personal PIN may be activated or deactivated by selecting the SERVICE Personal PIN setting in the service menu EMUTROMMEHT Personal PIN TIHE AHD DATE press ENTER Every software update deactivates the 3 STORE UP Pp D EXT DOWN Personal PIN secured menu items may PERSONAL Entry of date and time Invoke the submenu by P N be identified by the personal PIN logo as pressing START ENTER given in the service menu SUBMENU TIME amp DATE Service menu options ENUIRONMENTSTIME amp DATE Blz en order to avoid operating errors T me read through the basics at the begin ning of the Service Menu section Beer EXT I DOWN e Always remember to save your settings by pressing STORE e All menu items that comprise further submenus are displayed in CAPITAL LETTERS Set value Store Exit Select time or date STORE I UP EHUIRONMENHT BLA as i eee Select input anguage fields gt german i Be start set noel DHL ENT DOWN ee SCORE NUE ENUIRONMENTNTIME amp DATE Barz Sets the language of the menu Dake 19 88 88 Tu f Factory setting German 7 EXT J DOWN _ 26 Operating Instructions mon amie deluxe The menu item TIMER DEKOLIGHT offers you two switching cycles A and B for each day of the week NOTE SWITCHING CYCLES Using the setting m
50. to the settings Selectable function symbols for a fully equipped unit ae si Ja MP3 int Studio MP3 ext KIIJ iy C Booster AquaCool Aroma arn Klima The basic functions portrayed here refer to a fully equipped device If you have chosen a simpler equip ment package functions from the variable operating elements auto matically take the place of the miss ing basic function Operating Instructions mon amie deluxe 19 pic And deluxe Function overview Body fan The body fan is automati cally controlled by ACS As soon as you press one of UV tubes During the session you can switch the UV tubes on and off the fan buttons the auto matic mode is interrupted Keep pressed for 2 seconds awa gt Aquacool An ongoing spraying process cannot be stopped If the aquaCool supply is running Air conditioning After the air conditioning system has been switched off it cannot be restarted for three minutes for safety reasons If the system is switched on during this time the command will be stored The air conditioning system will be switched on automatically after a delay i e after the blocking time has elapsed If the condensate canister is full the following symbol flashes on the display AK See also the chapter Main tenance Air conditioning system low a corresponding message is displayed in the standby mode After the message has
51. tructions mon amie deluxe 29 30 AGIT ANUME deluxe AUDIO usb MPS Pp EXT DOWN Not available in this system 23 AUDIO MP Line In gt an oe ane pl EXT I DOWN J Activates and deactivates the line in connection au dio module for units from standard line level to low loudspeaker levels MP3 player iPod etc Factory setting on ORE Up AUDIO 17 22 Studio channel selection gt bed gt puls code ee 005 EXI DOWN Allows for the change over between pulse code and BCD code mode with the Studio signal pend ing and deactivates the external channel selection Factory setting bcd 25 De AUDIO Humber of studio channels I 1 EXT L DOWN _ If bcd has been preselected the number of channels available in the studio is specified here Factory setting 4 Operating Instructions mon amie deluxe ae AUDIO gt an gt otf Music nonstop Pp D EXT EL DOWN If this function is active music is played nonstop i e also out of tanning sessions Factory setting off Pt OR AUDIO en gt MPS internal gt Studio Line In Honskop music source 1 Ext DOWN Allows for choosing the permanent audio source for the Music nonstop function Factory setting MP3 internal a 05 OR AUDIO gt FE me 5 3 Default volume banning I 1 EXT DOWN _ Sets the volume for the collagen tanning mode Factory setting
52. us 1 9 10 3230074785 60x facial collagen booster 30x body collagen booster With air conditioning 10460W Without air conditioning 9200W Automatic fuse K type safety cut out 3 pole 3x25A with residual current operated circuit breaker RCD EQUIVALENCE KEY FOR UV FLUORESCENT LAMPS Marking of UV fluorescent lamps according to IEC 61228 Sample coding of a lamp 160 R 32 3 2 Use of replacement tubes The tanning tables referring to this sun bed are only valid as long as the system is operated with the original tube set Ratio of the NMSC effective UV irradiance lt 320nm und gt 320nm NMSC Non Melanom Skin Cancer Erythema effective UV irradiance in the range o 250 400nm in mW m Reflector types O For lamps without reflector B For lamps with reflector angles wider than gt 230 N For lamps with reflector angles narrower than lt 200 R For lamps with usual reflector angles of gt 200 lt 230 Indication of Watts electrical power Operating Instructions mon amie deluxe 55 MOV QI deluxe Remarks 56 Operating Instructions mon amie deluxe MOV Anue deluxe Remarks Operating Instructions mon amie deluxe 57 MOV QI deluxe Remarks 58 Operating Instructions mon amie deluxe KBL AG Ringstra e 24 26 56307 Dernbach Germany fon 49 0 26 89 94 26 0 fax 49 0 26 89 94 26 66 eMail mon amie kbl de www mon ami de
53. ut 1100 operating hours For further in formation see data sheet When necessary Characteris tic useful life time 10000 op erating hours After approx 1500 hours When necessary After approx 1000 hours Replace all ropes after 3000 hours When necessary When necessary mon amie deluxe Tools and aids Hexagon socket screwdriver SW 4 60 i mm Art No 3410055263 Standard Phillips screwdriver PH2 Phillips screwdriver PH2 90 offset L _ Hexagon socket spanner SW 4 Pipe wrench SW 19 Open ended spanner SW 10 Open ended spanner SW 13 Finally acknowledge a process by pressing the Start button interior display di Number of required persons The following chapters describe the work steps re quired for carrying out maintenance and care actions At the beginning of each chapter the required tools and aids are depicted unless the corresponding process can be carried out by one individual person without any further auxiliary equipment The assembly is basically carried out in reverse order of the disassembly Exceptions are especially pointed out If you open the bench part or one of the acrylic panes you must after closing acknowledge a warning message appearing on the interior display Pe ooo Figure 11 Press the bench slightly downwards and keep it pressed Open the lock Tilt up the bench TILTING UP THE BASE PANE ts Figure 12 TIA
54. vel to low loudspeaker levels These sources comprise e Studio music External players such as MP3 players mobile phones cell phones I pods etc EXTERNAL 100 V AUDIO SIGNAL FEATURE If you decide for a connection to a 100 V audio OPTIONAL system you will need a transformer KBL no 9100 0170 00 for the transmission of the audio signal This connection must be made by trained service staff EXTERNAL PLAYERS amp HEAD EARPHONES A line connection has been integrated on the right hand side of the bench s head end so that the unit user can connect his or her own player such as an MP3 player an iPod etc Take hold of the jack plug and pull the cable out of the opening Then connect the jack plug to the earphone jack of your player Then select MPS ext as the audio source from the control pan el of the unit before you start playing your own tracks from the player The tracks can only be selected via the user s own player The volume can be controlled via the control panel of the unit and also via the corresponding op erating elements provided by the user s player Either a headphone or an earphone with a 6 3 mm jack plug can be used The corresponding connector socket is located next to the line connector The au dio signal is switched over automatically Figure 5 on ATTENTION Danger of damage to the player due to overheating Do not place your player within areas that are directly
55. y Saturday Sunday 08 30 20 00 34 Operating Instructions mon amie deluxe 61 IT STORE UP 7 AROMA AGA AF TIMER AROMA press ENTER O o CO EXT T DOWN Entering switching times for the Aroma Timer The submenu is invoked by pressing START ENTER 7 SUBMENU TIMER AROMA SELECT DAY OF THE WEEK STORE I SR AFOMANTIMER AROMA gt gt Monday Sunday Seas A EXT gt SS Q gt Day OH gt Day OFF AR OLMIS MER AROMA TR STORE I UP Monday Ag HAS 24759 Select input Save settings fields pressing STORE start set ALAZ by DE ET JL DOWN Starts the Aroma test 1 cycle STORE I Oo UP AIE COHGITIOHIHE AL AZ Aircon air conditioning gt on s aff EXM DOWN J Switches the air conditioning unit on and off Factory setting on STORE L UP AIE CONLITIOHNING Be Az Start level body fan iS 1 ii E PT Ext D DOWN _ Specifies the start speed setting of the body fan at the beginning of the collagen tanning Factory setting 2 RCE Al AB RCE mode gt 2 CE Li 3 T EXT L DOWN _ Not available in this system This item easyCare is only available when mon amie terminal is connected a STORE I Up PIN EASYCARE SETTINGS press ENTER O o CO EXT 7 DOWN Submenu SETTINGS Invoked by pressing START ENTER SUBMENU EASYCARE SETTINGS easy

Download Pdf Manuals

image

Related Search

Related Contents

TECHCONNECT TC2-MATRIX MANUAL DEL PROPIETARIO  Virtual Sun VS3600-36 Instructions / Assembly  MIKE SHE WM – User Manual  Blusens Touch87 8GB Black, Grey  proVISION PIV User Manual  Samsung SMART CAMERA NX1000(20-50mm) 用户手册  ファイル【PDF:812KB】  M6 TURBO – Le 15/11/2009 – 11:36:13 – Extrait Succès  instruction booklet livret d`instruction manual de instruções  Samsung UA32B6000VV User Manual  