1. Data transmission equipment operating in the 2 4 GHz ISM band and using wide band modulation techniques Harmonized EN covering essential requirements under article 3 2 of the R amp TTE Directive Waste Electrical and Electronic Equipment 2002 96 EC The ONE80 respects the European directive on the waste disposal from the electric and electronic equipment Restricted use of Hazardous Substances RoHS 2002 95 EC The ONE80 respects the European directive on the restricted use of Hazardous Substances in electric and electronic equipment ONE80 Installation Manual Annexe A Console Cable Catalog reference 4 022 332 B 00 Ed A ToPC serial port in terminal mode Configuration RJ45 P1 SIGNAL SUB D 9 Pts Female P2 1 TX 2 2 RX 3 3 GND 5 ONE80 Installation Manual 23
2. 1 Part 2 Specification of environmental test Transportation careful Tra nsportation T2 3 Electromagnetic Compatibility immunity ETSI EN 301 489 17 V1 2 1 2002 08 ElectroMagnetic Compatibility EMC standard for radio equipment and services Part 17 Specific conditions for 2 4 GHz wideband transmission systems and 5 GHz high performance RLAN equipment ETSI EN 300 328 V1 6 1 Data transmission equipment operating in the 2 4 GHz ISM band and using wide band modulation techniques Harmonized EN covering essential requirements under article 3 2 of the R amp TTE Directive ETSI EN 300 386 V 1 3 3 2005 04 Telecommunication network equipment ElectroMagnetic Compatibility EMC requirements Waste Electrical and Electronic Equipment 202 96 EC The ONE80 respects the European directive on the waste disposal from the electrical and electronics components Restricted use of Hazardous Substances RoHS 2002 95 EC The ONE80 respects the European directive on the restricted use of Hazardous Substances in electric and electronic equipment ONE80 Installation Manual 3 3 1 3 1 1 Router Description Hardware Description This section details the various types of services offered by the ONE80 The described configurations are the maximum configurations for the motherboard and the extension modules Other configurations can be derived by under equipment
3. Chapter 1 Safety Instructions This chapter provides the safety instructions for use and installation of the router Chapter 2 Router Description This section describes the router front and rear panels and the associated technical characteristics Chapter 3 Interface Description This section describes the router interfaces Chapter 4 Installation This chapter describes how to modify the jumper positions and gives instructions to connect the router Chapter 5 Power up This chapter describes the device power up and how to monitor the self test progress Chapter 6 Technical Characteristics This section describes technical characteristics such as operating conditions Chapter 7 Directives and Standards This chapter details the list of standards which the device complies with Appendix Connection Description This chapter provides the pin out of cables that are compatible with the router ONE80 Installation Manual 3 Table of Contents HOW TO READ THISIMANUAL arti eei et Lie 3 TABLE OF CONTENTS i e aaa 4 1 SAFETY INSTRUCTIONS ite aaa ir ir 1 1 Connection to Power Supply 1 2 Overcurrent Protection eise te Pre ana aa 1 3 Safety Level Interface ariani 2 DIRECTIVES AND STANDARDS eet irn tti ie da e d AE Robe o dE nte aTa Rna 6 2 1 Declaration Cf CONTOURS eremo uenenum ast Re DER UH E eae 6 2 2 Standards st
4. Indeed the ONE80 can have fewer interfaces compared to those presented below The acronyms mentioned in bold between brackets locate markings of the interfaces back panel Motherboard Interface The ONE80 motherboard is equipped with the following interfaces The interface marking is indicated in bold and between brackets 1 G SHDSL access network 2 or 4 wires or IMA SHDSL 8 wires SHDSL 1 Console port CONSOLE 1 Managed switch 4 ports SWITCH 1 LAN access 10 100 Mbps ETHERNET Optional Interfaces factory mounted e WLAN 802 11b g with 2 antennas managed by the method antenna diversity ONE80 Installation Manual 3 2 Front Panel The front panel is provided with LEDS which inform about the status of several router functions Figure 1 Front Panel Leds OFF Green Red Blinking Red Orange Blinking Green Status Switched Switched On Switched On amp Reboot in Off amp Operational Not operational progress Uplink No All SHDSL All SHDSL lines Minimum one Minimum ISHDSL lines are are not configured one SHDSL lines synchronized synchronized SHDSL line is not line is in the configured loss of signal synchronized progress of loss of signal synchroniz ation IP Not used All IP All IP interfaces At least one interfaces are are down IP Interface up is not up example PPPoA not connected WLAN Notused Interface up Traffic in progress Aux No auto Auto Auto configur
5. ONE80 Installation Manual Version B April 2007 NETWORKS http www oneaccess net com ONEAC OneAccess 28 rue de la Redoute 92260 Fontenay aux Roses France The law of 11 March 1957 paragraphs 2 and 3 of article 41 only authorizes firstly copies and reproductions strictly reserved for use by copyists and not for general use and secondly analyses and short quotations for the purpose of example and illustration Therefore any representation or reproduction entire or partial made without the consent of the author or his representatives is illegal paragraph 1 of article 40 Any such representation or reproduction made in any manner whatsoever would therefore constitute an infringement of the law as sanctioned by articles 425 and in accordance with the penal code Information contained in this document is subject to change without prior notice and does not constitute any form of obligation on the part of OneAccess OneAccess and the distributors can in no case be held responsible for direct or indirect damage of any kind incurred as a result of any error in the software or guide Every care has been taken to ensure the exactitude of information in this manual If however you discover an error please contact OneAccess After Sales Service division Edition August 2006 1000 00 N 4022 844 C 00 ind B ONE80 Installation Manual How to Read this Manual The present document is broken down into 8 chapters
6. an be made available on request IEC 60950 1 2001 EN 60950 1 2001 First Edition EN300 386 V1 3 3 2005 04 EN301 489 17 V12 1 2002 08 EN300 328 V1 6 1 2004 11 Laboratoire Gyl Technologie pour la S curit Gyl Technologie Laboratory for Safety Laboratoire Gyl Technologie pour CEM Gyl Technologie Laboratory for EMC Le produit est marqu du symbole CE en application des directives cit es ci dessus The product is marked with the CE symbol in accordance with the directives mentionned above Responsable autoris Authorized signatory Directeur G n ral Chief Operating Officer Nom N LEN Go ONE80 Installation Manual 2 2 Standards The ONE80 is designed in conformity with the standards listed hereafter provided that the basic housing modules interface boards and installation kits are mounted as recommended in the corresponding installation manual s Safety EN60950 1 2001 First Edition Safety of information technology equipment including electrical business equipment Environment Climatic physico chemical mechanic packing ETS 300 019 1 95 Environmental conditions and environmental testing for telecommunication equipment In use Temperature Controlled Test specification class T3 1 normal class T3 1 exceptional Part 1 Classification of environmental conditions Storage partly temperature controlled T1
7. at configuration configuratio ion successfully nin completed progress ONE80 Installation Manual 9 3 3 Rear Panel This section details the various types of ONE80 rear panel so that the user can identify the interface type and port numbering Other configurations can be derived by not providing some interfaces represented on the product The configurations below are presented as an D It should be noted that only the fully loaded configurations are represented example OneAccess reserves the right to market them or not 10 ONE80 Installation Manual 3 3 1 Configuration The interface marking is indicated in bold and between brackets All the connectors are located on the rear panel 1 SHDSL access port RJ45 SHDSL 1 Configuration port and debug RJ45 CONSOLE 1 LAN access port 100Base T RJ45 ETHERNET 1 0 4 FastEthernet switch ports RJ45 SWITCH E3 0 3 to E0 0 0 Input for the external power supply connector DC input jack 12V 1 7A 2 connectors for WLAN antenna 9 9 E B CONSOLE mu Li LL Figure 2 Rear panel A Depending of the ordered configuration of the system the rear panel may change ONE80 Installation Manual 11 3 4 12 Configuration Identification The different device configurations are identified by adding one or several letters to the device naming and printed on the router labelling sticker Option codification e D G SHDSL access 1 to 2
8. ates aads 7 3 ROUTER DESCRIP HON priri 1 rii i ERE A Rae 3 1 Hardware Description iae RR RO can av eden e 3 2 Front Panel cao aaa GRA eri 3 3 Rear Panel m 3 4 Configuration Identification INTERFACE DESCRIPTION itii iru LIRA Ra 13 4 1 G SHDSL Interface SHDSL 13 4 2 Console interface CONSOLE 14 4 3 LAN 10 100 Mbps interface ETHERNET 15 44 Switeh Interface SWITCH ciicrn a ie 16 5 INSTALLATION 5 1 le ceto E M 6 POWER UP Vra E OS e e ERR TCR SERERE RENE HERPES UR RARE RN 18 7 TECHNICAL CHARACTERISTICS 5 rette tet ir teet i yer bete b i e reiecta ra es 19 7 1 Climatic Environment 5 2 a RO Ri 19 7 2 Power Supply 7 3 iDImensionsz RR ART E AA ROLO 8 8 1 8 2 ANNEXE A CONSOLE CABLE cir areir eia EAr LAEE SETAE E RIA RIO 23 4 ONE80 Installation Manual 1 Safety Instructions The following symbol instructs the user to read the manual carefully before any connection IK 1 1 Connection to Power Supply To connect the power supply always follow these steps e Connect the DC input jack from the power supply to the DC 12V power input on the rear panel of the router e Connect the power supply to an AC electrical outlet 100 240 VAC Plugging in the power supply turns on the router device The AC input is the part you must disconnect first For safety rea Ih Unplug the AC input before assembling disassembling any part on the e sons you shall be abl
9. e to easily access this part 1 2 Overcurrent Protection The product requires that the building s electrical installation is designed for protection against short circuit over current protection A fuse or circuit breaker no larger than 240 VAC 10A must be used on the phase conductors 1 3 Safety Level Interface All safety levels of the interfaces are described in each paragraph presenting the interfaces paragraphs 3 1 to 3 4 products authorized by OneAccess and only by qualified staff as Ih The interface modules and optional boards can be installed only in the LAN recommended in the installation manual ONE80 Installation Manual 5 2 1 Directives and Standards Declaration of Conformity D claration de conformit suivant les directives R amp TTE DBT et CEM Declaration of Conformity according to R amp TTE LVD and EMC directives ONE80 Routeur et adaptateur de r seau Router and network adapter Tension d alimentation Supply voltage 200 240 Vac 20 W 50 60 Hz 12V 1 7A Avec les cartes with the cards WiFi Nous d clarons que ce produit est pr sum conforme aux exigences essentielles applicables des directives suivantes du Parlement Europ en et du Conseil la Directve R amp TTE 19995 CE du 9 mars 1999 concernant les quipements hertziens et les quipements terminaux de t l communications et la reconnaissance mutuelle de leur conformit la Directive Basse Tension 73 23 CEE du 19 f vrie
10. ftware initialization was successful e The STATUS LED blinks in case of software absence or error during software loading Refer to the Software and ONEOS User Guide for more information 18 ONE80 Installation Manual 7 Technical Characteristics 7 1 Climatic Environment Operating Conditions Temperature 0 C lt T lt 45 C Relative Humidity HR 5 lt HR lt 80 Absolute Humidity lt 24g m3 Altitude lt 2500 m Storage Environment Temperature 25 C to 55 C Relative Humidity HR 5 lt HR lt 80 Absolute Humidity lt 24g m3 Altitude lt 2500 m 7 2 Power Supply External Power Supply 100 240 VAC 20W 12V 1 74 7 3 Dimensions The dimensions of the housing are Width 320 mm Height 1U Depth 200 mm ONE80 Installation Manual 8 Directives and Standards 8 1 Declaration of Conformity In progress 20 ONE80 Installation Manual 8 2 Standards The ONE80 is designed in conformity with the standards listed hereafter provided that the basic housing modules interface boards and installation kits are mounted as recommended in the corresponding installation manual s Security EN60950 1 2001 Safety of information technology equipment including electrical First Edition business equipment Energy ETSI EN 300 132 Power supply interface at the input to telecommunications equipment Operated by alter
11. ion of crossover straight cable auto MDI MDI X detection the transmission pairs are 1 2 and receive 3 6 16 ONE80 Installation Manual 5 Installation Always unplug the power AC cable before any hardware maintenance 7 operation This chapter describes how to connect the router 5 1 Connection The external power supply is connected on the rear panel of the device The external power supply is delivered with the router package e Connect the jack connector of the external power supply to the DC 12V 1 7A power input device connector e Connect the DC input jack from the power supply to the DC 12V 1 7A power input on the rear panel of the router e Secure the power supply connection by installing the DC power supply cord into the plastic ring Y The device shall not be used with another power supply than a power A supply provided by OneAccess ONE80 Installation Manual 17 6 Power up To power up the device always follow these steps e Connect the DC power input jack from the power supply to the DC power input of the rear panel of the router e Connect the power supply to the AC mains 100 240 V AC The connection of the power supply causes the switch on of the equipment Few seconds after power on the device performs a series of self tests and loads the software into memory RAM during which the STATUS LED on the front panel blinks e The STATUS LED light remains steady green if so
12. nating current ac derived from direct current dc s Part 1 sources ETSI EN 300 132 3 Power supply interface at the input to telecommunications equipment Part 3 Operated by rectified current source alternating current source or direct current source up to 400 V Security Environment Climatic physico chemical mechanic packing ETS 300 019 1 95 Environmental conditions and environmental testing for telecommunication equipment In use Temperature Controlled Test specification Part 1 Classification of environmental conditions class T3 1 normal class T3 1 exceptionnal Storage partly temperature controlled T1 1 Part 2 Specification of environmental test Transportation careful transportation T2 3 ONE80 Installation Manual 21 22 Telecom ITU T K21 on G SHDSL 2003 07 Resistibility of telecommunication equipment installed in customer premises to over voltages and over currents Electromagnetic Compatibility immunity EN 300386 V 1 3 3 2005 04 Telecommunication network equipment ElectroMagnetic Compatibility EMC requirements EN 301489 17 V1 2 1 2002 08 ElectroMagnetic Compatibility EMC standard for radio equipment and services Part 17 Specific conditions for 2 4 GHz wideband transmission systems and 5 GHz high performance RLAN equipment EN 300328 V1 6 1 2004 11 Wideband transmission systems
13. pairs 2 to 4 wires e M IMA access G SHDSL 4 pairs 8 wires e W Wireless LAN Example ONE80 M is an ONE80 router equipped with e 1 IMA access G SHDSL 8 wires ONE80 Installation Manual 4 Interface Description 4 1 G SHDSL Interface SHDSL 4 1 1 Safety Level of G SHDSL SHDSL Interface The G SHDSL interface is TNV 1 Telephone Network Voltage type 1 It must be connected to a standard telephone line external 4 1 2 Characteristics e ITU T G 991 2 for the G SHDSL Annex A and B 2 or 4 wires e Capacity e SHDSL 1 pair 2 wires 192 kbps up to 2 320 kbps e SHDSL 2 pairs 4 wires 384 kbps up to 4 640 kbps e SHDSL IMA G SHDSL 4 pairs 8 wires 768 kbps up to 9 280 kbps 4 1 3 Connector Pinout RJ45 connector 4 1 4 Cables For the connection of the G SHDSHL interface use the shielded cable that comes with the equipment ONE80 Installation Manual 13 4 2 Console interface CONSOLE 4 2 1 Characteristics e RS232 e 9600 bps e 8bits 1 bit for stop no parity 4 2 2 Connector Pinout RJ45 connector e X Emission e RX Reception e NC Not Connected e GND Ground 4 2 3 Cable The console cable is defined in Appendix A 14 ONE80 Installation Manual 4 3 LAN 10 100 Mbps interface ETHERNET 4 3 1 Safety level of LAN 10 100 Mbps interface The Ethernet 10 100 Mbps auto sense has a SELV Safety Extra Low Voltage interface They must be
14. r 1973 concernant le rapprochement des l gislations des Etats Membres relatives au mat riel lectrique destin tre employ dans certaines limites de tension la Directive CEM 89 336 CEE du 3 mai 1989 concernant le rapprochement des l gislations des tats membres relatives la compatibilit lectromagn tique modifi e par la Directve 92 31 CEE du 28 avril 1992 We declare that this product has been given a presumption of conformity with the applicable essential ido rog of the following directives of the E uropean Parliament and of the Council R amp TTE Directive 1999 VEC of march 9 1999 on radio equipment and telecommunication termina equipment and the mutual recognition of their conformity Low Voltage Directive 7323EEC of february 19 1973 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain votage limits EMC Directive 89 336 EEC of may 3 1989 on the approximation of the laws of the Member States relating to electromagnetic compatibility amended by Directive 92 31 EEC of april 28 1992 Nous d clarons que les normes harmonis es suivantes ont t utilis es pour d montrer cette pr somption de conformit et ont donn lieu aux rapports de tests suivants disponibles sur demande We declare that the following harmonised standards were used to demonstrate this presumption of conformity and the results are included in the following tests reports which c
15. used only for indoor applications connected to a 10 100 Mbps interface which has also the SELV characteristics 4 3 2 Characteristics 10Base T and 100Base TX Half or full duplex Auto negotiation Auto MDI MDIX 4 3 3 Meaning of LED Colors Green LED Lit Link active Blinking yellow LED Traffic in progress 4 3 4 Pinout RJ45 Connector 4 3 5 Cables The cables are shielded crossover straight cables with 4 twisted pairs The switch supports auto detection of crossover straight cable auto MDI MDI X detection the transmission pairs are 1 2 and receive 3 6 ONE80 Installation Manual 15 4 4 Switch Interface SWITCH 4 4 1 Safety level of Switch interface The Ethernet 10 100 Mbps auto sense has a SELV Safety Extra Low Voltage interface They must be used only for indoor applications connected to a 10 100 Mbps interface which has also the SELV characteristics 4 4 2 Characteristics The Ethernet Switch function offers 4 additional Ethernet ports Each of this port can be switched and or routed 10 100 Mbits s Half or full duplex Auto negotiation Auto MDI MDIX 4 4 3 Meaning of LED colors Green LED Lit Link active Blinking yellow LED Traffic in progress 4 4 4 Connector Pinout RJ45 connector 4 4 5 Cables The cables are shielded crossover straight cables with 4 twisted pairs The switch supports auto detect

Download Pdf Manuals

image

Related Search

Related Contents

II Jornadas Empresariais - "A re-industrialização do  Biofongicide sous forme de poudre mouillable Pour  19798-6NL-03 PNOZ X2P  Untitled      PDF形式/559KB  Inst Manual PV9DH 06..  Function Block - Schneider Electric  Modèle de Cahier spécial des charges  

Copyright © All rights reserved.
Failed to retrieve file