Home

USER MANUAL

image

Contents

1. F Power Supply Jack lt Figure 1 The Location of the Model 2036P Configuration Switches To configure your unit use a small screwdriver and gently push each switch to its proper setting The ON and OFF positions are shown in Figure 2 Default settings for the DIP switches are shown in the table on the following page Detailed settings follow the table 12345678 ON 0 I OFF OFF Figure 2 The miniature configuration switch package 4 DIP SWITCH SUMMARY TABLE Position Function Factory Default Swi Flow Control Off Hardware SW2 Bit Error Rate Test Off De Activated SW3 Data Parity Stop Bits Off SW4 Data Parity Stop Bits Off 8B NP 1S SW5 Data Parity Stop Bits Off SW6 Data Rate Off SW7 Data Rate Off 38400 bps SW8 Data Rate Off 3 2 CONFIGURATION SWITCHES SW1 SW8 This section provides detailed information about the function of each DIP switch and lists all possible settings Switch 1 Hardware Software Control BERT Direction The setting for Switch 1 determines whether the 2036P uses hard ware or software i e XON XOFF flow control Switch 1 is alternative ly used to determine the direction of the BERT output message when ever the BERT is activated See Switch 2 below Flow Control SW1 BERT Direction SW1 Hardware OFF Parallel OFF Software ON Serial ON S
2. ISO IM An IS0 9001 Certified Company USER MANUAL MODEL 2036P High Speed Parallel to Serial Serial to Parallel Interface Converter THE PATTON Ba Elecironics To Part 07M2036P C SALES OFFICE Doc 102142UC Revised 6 8 98 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com 1 0 WARRANTY INFORMATION Patton Electronics warrants all Model 2036P components to be free from defects and will at our option repair or replace the prod ucts should they fail within one year from the first date of shipment This warranty is limited to defects in workmanship or materials and does not cover customer damage abuse or unauthorized modifi cation If these products fail or do not perform as warranted your sole recourse shall be repair or replacement as described above Under no condition shall Patton Electronics be liable for any damages incurred by the use of these products These damages include but are not lim ited to the following lost profits lost savings and incidental or conse quential damages arising from the use of or inability to use this prod uct Patton Electronics specifically disclaims all other warranties expressed or implied and the installation or use of this product shall be deemed an acceptance of these terms by the user 1 1 RADIO AND TV INTERFERENCE The Model 2036P generates and uses radio frequency energy and if not installed and used properly that is in str
3. E LIB E k LIB Seed Copyright 1998 Patton Electronics Company All Rights Reserved 11
4. DIX A PATTON MODEL 2036P SPECIFICATIONS Interface Connectors Data Rates Power Supply Flow Control Data Format Temperature Range Altitude Humidity Dimensions Weight Asynchronous RS 232C compatible Serial DB 25 female Parallel Centronics 36 pin male 0 115 200 Kbps 1 Uses power from RS 232 interface 2 9VDC 500mA power supply 3 Typical Maximum power consumption 100mW 95V 20mA Serial Side as DCE CTS 5 DSR 6 Serial Side as DTE 20 7 or 8 bits 1 or 2 stop bits even odd or no parity 0 50 C 32 140 F 0 10 100 feet 5 to 95 non condensing 4 35 x 2 9 x 0 8 11 0mm x 7 4mm x 2 0mm 2 6 oz 73 8 grams APPENDIX PATTON MODEL 2036P INTERFACE CONNECTIONS 36 PIN CENTRONICS PARALLEL PORT CONNECTIONS Pin Description Direction 1 Strobe Output 2 Data bit 0 3 Data bit 1 4 Data bit 2 5 Data bit 3 6 Data bit 4 7 Data bit 5 8 Data bit 6 9 Data bit 7 10 Acknowledge Input active low 11 Busy Input active high 12 Paper end 13 Select 18 5 volts 32 Error tied to 5 16 17 19 20 21 22 23 24 25 26 27 28 29 30 33 36 Ground Note All other pins are unconnected DB 25 PORT CONNECTIONS Pin Name Description 1 2 3 FG Connected to pin 7 TXD Transmit Data Power source when conn to DTE RXD Receive Data sends XON XOFF only Power source when connected to DCE RTS Request to Send Power source when c
5. F ON 4800 ON ON OFF 9600 OFF ON ON 19200 ON ON ON 38400 OFF OFF OFF 57600 ON OFF OFF 115200 OFF ON OFF 4 0 INSTALLATION The Patton Model 2036P are very simple to install Once you have configured the DIP switches just plug your converter in to a stan dard cable and you re ready to go Figure 3 illustrates the proper con nections for the Model 2036P If you have special ordered a non stan dard connector your connections may be different Serial Interface aM Model 2036P p d Your cable i Printer PC BET Parallel Interface Pigure 3 Installing the Model 2036P 4 1 POWER CONNECTION In many cases the Model 2036P will run without being connected to external power However additional power may be necessary in certain applications that use low power RS 232 devices The 120VAC U S wall transformer version supplies 9V regulated DC up to 500mA Connect this wall transformer to the Model 2036P by means of a cannon jack on the side panel The Model 2036P is powered up as soon as it is plugged into an AC outlet there is no power switch 5 0 OPERATION Once your interface converter is properly configured and installed it should operate transparently as if it were a standard cable connec tion Operating power is derived from the RS 232 data and control sig nals there is no ON OFF switch APPEN
6. er may be obtained from Patton Electronics Technical Support 301 975 1007 http www patton com or sup port paiton com NOTE Packages received without an RMA number will not be accepted Patton Electronics technical staff is also available to answer any questions that might arise concerning the installation or use of your Model 2036P Technical Support hours 8AM to 5PM EST Monday through Friday 2 0 GENERAL INFORMATION Thank you for your purchase of this Patton Electronics product This product has been thoroughly inspected and tested and is warrant ed for One Year parts and labor If any questions or problems arise during installation or use of this product please do not hesitate to con tact Patton Electronics Technical Support at 301 975 1007 2 4 FEATURES Converts parallel data to serial data and vice versa Automatically selects parallel to serial and serial to parallel operation Automatically selects DCE DTE modes Serial data rates to 115 200 bps Supports both software and hardware flow control Interface or AC Powered Ultra miniature size Made in the USA 2 2 DESCRIPTION The Patton Model 2036P Serial to Parallel and Parallel to Serial Converter automatically converts RS 232 serial data to parallel data format and vice versa Incorporating advanced microprocessor technology the 2036P automatically senses and selects parallel and serial modes as well as DCE DTE modes The Model 2036P sup
7. ict accordance with the manufacturer s instructions may cause interference to radio and television reception They have been tested and found to comply with the limits for Class A computing devices in accordance with the specifi cations in Subpart J of Part 15 of FCC rules which are designed to provide reasonable protection from such interference in a commercial installation However there is no guarantee that interference will not occur in a particular installation If they do cause interference to radio or television reception which can be determined by disconnecting the RS 232 interface the user is encouraged to try to correct the interfer ence by one or more of the following measures moving the comput ing equipment away from the receiver re orienting the receiving anten na and or plugging the receiving equipment into a different AC outlet such that the computing equipment and receiver are on different branches 1 2 CE NOTICE The CE symbol on your Patton Electronics equipment indicates that it is in compliance with the Electromagnetic Compatibility EMC directive and the Low Voltage Directive LVD of the Union European EU A Certificate of Compliance is available by contacting Technical Support 1 3 SERVICE All warranty and non warranty repairs must be returned freight prepaid and insured to Patton Electronics All returns must have a Return Materials Authorization number on the outside of the shipping container This numb
8. onnected to DTE CTS Clear to Send Power source when conn to DCE DSR Data Set Ready Power source when conn to DCE SG Signal Ground DCD Carrier Detect Power source when conn to DCE V in Used as an external power source DTR Data Terminal Ready Power source when conn to DTE Note All other pins are unconnected APPENDIX C PATTON MODEL 2036P FACTORY REPLACEMENT PARTS AND ACCESSORIES Patton Model Description O8059DCI 230VDC 49V 5 reg DC 500mA International Adapter 0805B 110VDC 9 5 reg DC 500mA American Adapter O7M2036P User Manual 10 APPENDIX C PATTON MODEL 2036P BLOCK DIAGRAM HiPIZDI HSIHSAWOO THESIS Tuy 13 0 0 A 1 B OLINOIN NEL ALI drHLO nr oce A ddarie E aa H04 SONILISS UM aa HOLAS dia z Horcdness HJA d aod f 5 usd 18534 Mnoag wr Band HoHHS BF Lomas ET TOHIHOS ASNE FF MOSSIOOu i one ar oa sz B aooaa SOIMNOHINSO aso 8 LIB wid 8 Uz Hid BOw4HBANI 2 vea E alo raoa aia ui 5 LIB wid sB wid 85 ISTIS LIB T
9. ports serial data rates to 115 2 Kbps For easy configuration the Model 2036P features a convenient set of configuration switches These internally accessible configuration switches allow the user to control baud rate parity word length and flow control Housed in a miniature ABS plastic case the Model 2036P comes equipped with a DB 25 female connector on the serial side and a Centronics 36 pin male connector on the parallel side Able to recieve power directly from the RS 232 interface the Model 2036P also comes with a wall mount power supply for low power applications 3 0 CONFIGURATION The Model 2036P is simple to install and designed for excellent reliability The following instructions will help you set up and install your converter properly If you have any questions please call Patton Technical Support at 301 975 1007 3 4 CONFIGURATION SWITCHES The Model 2036P uses a set of eight internal DIP switches see Figure 1 that allow configuration to a wide range of applications You must open the case to gain access to the internal switches To open the case insert a small screwdriver into one of the slots on the side of the plastic case Then twist from side to side until the case opens The configuration switches allow you to select data rates parity word length and flow control selection The following section describes all switch locations positions and functions Parallel Port DIP Switches Serial Port E
10. witch 2 Bit Error Rate Test BERT Use Switch 2 to activate a Bit Error Rate Test BERT in the direc tion of the serial or parallel interface This test can be used to deter mine whether the 2036P is working properly When BERT is activated the 2036P outputs the following Barber Pole pattern which represents every ASCII character on a standard US keyboard 0123456789 lt gt ABCDEFGHIJALMNOPQRSTUVWXYZ _ abcdefghijkimnopqrstuvwxyz Bit Error Rate SW2 BERT Activated ON BERT De activated OFF NOTE When you activate the BER Test the 2036P memorizes the setting of Switches 1 53 54 55 S6 S7 and S8 to perform the test If you modify any of these switches you must de activate Switch 2 in order for the changes to take effect 5 Switch 3 through 5 Data Parity and Stop Bit Switches 3 through 5 are used to specify the data parity and stop bits The following table shows the settings that may be used Stop Data Parity Bit S W3 SW4 SW5 7B EP 1S ON ON ON 7B OP 15 OFF ON ON 7B NP 28 ON OFF ON 7B EP 28 OFF OFF ON 7B OP 28 ON ON OFF 8B EP 1 ON OFF 8B OP 1S ON OFF OFF 8B NP 15 OFF OFF OFF Switches 6 through 8 Frequency and Data Rate Switches 6 through 8 determine the frequency and data rate The following chart shows the settings that may be used Serial Data Rate Data Rate SW6 SW7 SW8 1200 OFF OFF ON 2400 ON OF