User Manual Single Door Access Control
Contents
1. Single Door Access Control User Manual Catalog Status indication ooo sre Operation instruction Enter Program mode ebebadbicdeaescuacetsdadescsdsacuacene Function setup seaadssaisuatedeucasaeaeenasentisnanne The exit key aveddieiiadvecudssnstdsscsceteetvaseess The doorbell key RARER REANA AARAA TET Tere rcree reer reir Modify card password Restore to factory default setting Operation example Setting Program password 789000 Continuously presenting cards to register eee Continuously register 2 cards 0088 O099 eeeeeesesem Delete cards according the Card number wre Setup the opening mode as presenting cards veee Setup the opening password as 147258 eeeseseesmeu Setting new password 888999 in Card and Password Mode Special cases External readers Light change indication Normal open close under special conditions Only the card can open the door or only the password can open the door Faults judgment Cards cannot open the door No response after presenting the card SPPEEEE EEE EEE EEE EEE EEE EEE EEE EEE LEE een No key response Wiring instruction WwW W PD P RBH PW WW o on o1 Faults Judgment Status Indication Faults Judgment 1 Cards cannot open the door Making sounds but the green light is off please check the card is registered or not Making sounds bu
2. and increase gradually The largest number cannot exceed 6399 If the registered already exist the number will increase from the number of previous registered cards including the deleted cards If add successfully the buzzer will make two short sound di di otherwise make along sound di a ra S l Operation Example Special case and faults Judgment 3 Key 2 register a single card allow registering card continuously 3 Continuously register two cards 0088 0099 press 2 gt present the card input the 4 digit user number press ENT present another allowing register many cards continuously card input the 4 digit user number press ENT continuously register cards gt Firstly enter the program mode press the ENT 4 times input password 123456 press ENT press 9 to exit press ENT again green light flashes press 2 present the new cards input the Note The system will give an default password 888888 to each card Such password can number 0088 press ENT present the second card input the number 0099 only be used in the Card and Password Mode press ENT press ENT once again Then press 9 to exit card 0088 and card 0099 If the card has already existed the buzzer will make along sound di Then you can can op
3. Key 4 Door open mode setting press ENT again green light flashes press 4 press 0 gt press ENT Then press Card or password press 4 0 gt press ENT press 9 to exit that is the factory default 9 to exit the opening mode has been changed to Card or Password Mode mode 6 Setup the opening password as 147258 Card and password press 4 1 press ENT press 9 to exit Firstly enter the program mode press the ENT 4 times input password 123456 Password press 4 2 gt press ENT press 9 to exit press ENT again green light flashes press 6 input 147258 press ENT gt 6 Key 5 Door open time setting press 147258 again press ENT once again Then press 9 to exit press 147258 Press 5 input time press ENT gt press 9 to exit then press ENT to confirm and you can open the door now Note The time format is e g 03 represents that the open time is 3 seconds 7 Setting new password 88899 in Card and Password Mode should operate it in the when time is set as 99 seconds the open method is trigger mode presenting card and Card and Password Mode the door open presenting the card again then the door close Press 9 presenting the card previous registered card input the original password 7 Key 6 s
4. card number when register cards for external readers you can only set serial Noto C this pazewordls onlyvalldin Card and Pas WOIE Moce lle an ie aar emro i w i y valid i w ini If modify successfully the buzzer makes 2 di di short sounds then it will exit the Shenae readers Vou cam also Npr password to open the cent Viat Program Mode According to the changes of the red light you can know current opening mode which can be 6 oe to Ee fare A ena Sind prepreg program passwords and parameter divided into 3 cases settings and authorized cards will not be delete With power off short the JP1 jumper to2and3 position Then with power on after hearing 2 ih po oe 0 5 ble petits eae mode di di sounds short the Jp1 jumper to 1 and 2 positions Then modify successfully Red light flashes every 1 second password mode Operation Example If red light and green light are on at the same time it means that the relay is closed and the 1 Setting New program password 789000 output is trigger mode Firstly enter the program mode press ENT 4 times input password 123456 press 3 Normal open close under special conditions presenting cards to open or close the ENT again green light flashes gt press 0 gt input the program password 789000 gt relay will have no auto response press ENT gt input the password 789000 again Then press 9 to exit the default Enter the Program Mode s
5. en the door present another card If the inputted number has already existed the buzzer will make 4 Delete cards according the card number e g delete the card 0088 and the card 0099 along sound di Then you can input another number Firstly enter the program mode press the ENT 4 times input password 123456 4 Key 3 delete the register card press ENT again green light flashes press 3 press 1 input 0088 press Delete card press 3 0 present the card present the another card Continuously present ENT input 0099 press ENT press ENT once again Then press 9 to exit card the card that need to be deleted press ENT press 9 to exit 0088 and card 0099 cannot open the door now Deleting multiple cards means that you Delete the user number press 3 1 input the user number press ENT gt input another can input number one by one Then press ENT In this case you can delete multiple cards one press ENT continuously delete many user numbers gt After confirming press the ENT once again press ENT gt press 9 to exit 5 Setup the opening mode as presenting cards Delete allthe cards press 3 2 gt input 9999 press ENT press 9 to exit Firstly enter the program mode press the ENT 4 times input password 123456 gt 5
6. et 99 seconds opening time the controller relay s output turns to password 123456 turns to 789000 Please remember the modified program password trigger mode That is to say when presenting the card to open the door the lock remains open It has to be used to enter the program mode later When presenting the cards again the lock remains close 2 Continuously presenting cards to register 4 Only the card can open the door or only the password can open the door Firstly enter the program mode press the ENT 4 times input password 123456 gt only card can open the door press ENT again green light flashes gt press 1 gt present new cards after presenting all Firstly set the opening mode as Card or Password Mode Then set blank opening password the needed cards press ENT Then press 9 to exit the registered card can open the only password can open the door 3 door now Set the opening mode as Password Mode There is no response when presenting the card 4
7. etup the door open password the factory default open password is blank 888888 the original program password If you have modified it please use the modified Door open password setting press 6 gt input the new password gt press ENT gt input one to operate the next step The red light and the green light flash one after another gt password again press ENT press 9 to exit input the new password 888999 press ENT press 888999 again press ENT Blank password setting press 6 gt press ENT press ENT press 9 to exit Note Sy Sarena ee toma or Password Mode and the Card and Password Special case and faults Judgment If itis blank password setting the password mode can not be used Can not open the door via password 1 External readers 3 Theexit key is 9 p When use the external readers to register and delete cards external readers have video 4 The doorbell key is ESC and audio indication so please take attention to that when presenting another card 5 Modify card password should operate in the Card and Password Mode If the external reader has no above indication please wait 2 3 seconds to present after the Press 9 the red light is off and the green light is on present the card must be authorized first one cards input the original password the original password is 888888 gt press ENT input If have to set
8. nd password mode Flash every 0 5 second Password mode Flash every 1 second keyboard eae short Successful Setting eae Failure Setting makmga long sound di Invalid inputting Making a long sound di Continuous sound Alarm di di di di Status Indication Operation Instruction 1 Enter Program mode Press ENT 4 times input password 123456 press ENT to save enter the program mode successfully Note 123456 is default password If entering the program mode successfully the buzzer will make two short sound di di otherwise make along sound di 2 Function setup All the following steps should begin with Entering Program Mode 1 Key 0 modify program password Press 0 input new password press ENT input the new password again press ENT press 9 to exit Note If add successfully the buzzer will make two short sound di di otherwise make a long sound di The password is 6 digits one 2 Key 1 register cards in continuous way press 1 continuously presenting the unregistered card press ENT to confirm press 9 to exit Note The system will give a number to each card The original password is 888888 Such password can only be used for Card and Password Mode If there is no card in the system the card number will start from 0001
9. t the green light and the red light flash at interval Check the Opening Mode Status Making sounds and the green light is on Check wire connection 2 Noresponse after presenting the card Check the card format or whether the card has been damaged Check the opening mode In Password Mode there will be no reader function and no response after presenting cards Check light indication When the red light is off and the green light on it is door open status There will be no response after presenting cards 3 No key response Check the indication light When the red light is off and the green light on it is door open status There will be no key response Wiring instruction 7 pin wire Purple OPEN exit button Black GND Red 12V White D1 external Green DO reader Blue LED Yellow BEEP 5 pin wire Red 12V power Black GND Grey NC relay signal Black COM output Brown NO 2 pin wire Yellow doorbell Blue Instruction Red light Green light Buzzer Working On Program mode flash Program mode sub menu On Presenting unregistered On Make long sound di card Presenting registered On time be identical Presenting registered card amp door open with door open card amp door open After Presenting the card and need to input the passwords Red light and green light are at interval flash aa short sound Card a